HomeMy WebLinkAbout2003 Costa Del Mar Rd; 679; CBR2019-3497; PermitBuilding Permit Finaled
Residential Permit
Print Date: 06/15/2020
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2003 Costa Del Mar Rd, 679
BLDG-Residential
2162100303
$40,835.78
Work Class: Alteration
Lot#:
Reference #:
Construction Type
Bathrooms:
Orig. Plan Check#:
Plan Check #:
(city of
Carlsbad
Permit No: CBR2019-3497
Status:
Applied:
Issued:
PermitFinal
Close Out:
Closed -Finaled
12/10/2019
03/02/2020
Inspector: CRenf
Final
Inspection: 06/15/2020
Description: MURPHY: 878 SF REMODEL TO PARTITION LIVING// REMODEL KITCHEN AND BATH// ADD LAUNDRY
Applicant: Owner:
GEORGE BROWN GEORGIA MURPHY
2003 Costa Del Mar, 653
CARLSBAD, CA 92009
FEE
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $744.59 Total Payments To Date: $744.59 Balance Due:
AMOUNT
$348.40
$243.88
$41.00
$42.00
$62.00
$2.00
$5.31
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Buildin Division
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Page 1 of 1
----· ----•--"·
(_ City of
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
:::~ vca~::k 'i~~~~ii
PC Deposit
Date ~'~a_,_,/ l~<>-1I~9-
JobAddress 2003 Cos·tA DEi.. MA.12 Rd Suite: 01q APN: _________ _
CT/Project#:. _________________ Lot#:. ___ _
Fire Sprinklers: yes/@ Air Conditioning: yes/ no Electrical Panel Upgrade: yes/@)
BRIEFDESCRIPTIONOFWORK: REMODEL LltvlT IN1ERIOR INCu..J.j))nC.. KlTCH:J=ll'-I
AN.b BATl·H•-OOIV\.$
0 Addition/New: _____ Living SF, ___ Deck SF, ___ Patio SF, ___ Garage SF
Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __
~ Remodel: 6 ]B SF of affected area Is the area a conversion or change of use? Yes !¢I§)
Additional Gas or Electrical Features? 0 Pool/Spa: ____ SF -------------
□ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
LJ Reroof: --------------------------------------
□ Plumbing/Mechanical/Electrical Only: ________________________ _
D Other: ---------------------------------------
APPLICANT {PRIMARY CONTACT) \\ PROPERTY OWNER G<.a e'I'"\ ' , I
Name: Geoie BrowicJ • Home bc;:s;c:,n. Name: Gcor<J IA M u•rf>bu
Address: 74 E. Vl'ILLey'. PA R.KWt:<'I Address: 2003 Cos TA D-el MAr Rd
City: ti; scorn>i.OQ State: cA Zip: 9 2.02.5 City: CA RL5 BAJ:> State: c.A Zip: 9 2.QcR
Phone: 6;5"8-'{'-lq-9 319 Phone: i:J 58 -.Z<j 3 -I 5f>-5
Email: 1:r:O"'jc:6® ~c.llct::'1homedes"i,p~;-Email: q=r:~lo M<,1v::pb,t@ coroaves com
DESIGN PROFESSIONAL
Name: _________________ _
Address: ________________ _
City: ________ State:. ___ .Zip: ____ _
Phone: _________________ _
Email: _________________ _
Architect State License: ___________ _
CONTRACTOR BUSINESS
Name: j A Me; 5 8 U\142,l?ti I ·e
Address: e>l70 Rot-Jso;J Rd,
City: San j)1ec,,o State: CA
Phone: 858-516-3 400
NEXT l.S'V!:='L H::oroC
s+e<=-
Zip: 9 z.11 I
Email: Jc.mes@ n ex±l:eve\ ba:ooe-co""'
State License: 12Z59o Bus. License: ______ _
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
□ J have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
□ I have and will maintain worker's compensation, as required by Sectlon 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _
Polley No. ______________ Expiration Date: _________ _
□ Certificate of Exemption: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the labor Code,
interest and attorney's fees.
CONTRACTOR SIGNATURE: LJAGENT DATE: ----------------------------
( OPTION B ): OWNER-BUILDER DECLARATION,
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, wll/ do the work and the structure is not intended or offered for sale (Sec,
7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale),
,(,, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec, 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
□ Jam exempt under Section ________ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: ~~ ~GENT DATE: /2-6-/'f
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code).
Lender's Name: _____________________ _ Lender's Address: _____________________ _
9NLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS _ONJY;
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air qual!ty management district? □ Yes O No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANlY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
J hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. t ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations overS'O' deep and demolition or construction of structures over 3 stories In height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 d (Section 106.4.4 Uniform Bu' ingCode).
1635 Faraday Ave Carlsbad, CA 92008
8-1
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 of 2
Email: Building@carlsbadca.gov
Rev. 06/18
Building Permit Inspection History Finaled
(City of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2019-3497)
Permit Type: BLDG-Residential Application Date: 12/10/2019 Owner: GEORGIA MURPHY
Work Class; Alteration Issue Date: 03/02/2020 Subdivision: LA COSTA CONDOMINIUM #4
Status: Closed -Finaled Expiration Date: 03/03/2021 Address: 2003 COSTA DEL MAR RD, # 679
IVR Number: 23580 CARLSBAD, CA 92009-6802
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
03/1812020 0311812020 BLDG-84 Rough 122459-2020 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
04/0912020 0410912020 BLDG-17 Interior 124500-2020 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06115/2020 06115/2020 BLDG-Flnal Inspection 130092-2020 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLOG-Electrical Final Yes
Monday, June 15, 2020 Page 1 of 1
DATE: 2/25/2020
JURISDICTION: Carlsbad
PLAN CHECK#.: cbR2019-3497
✓• EsG1I
A S.£\FEbu1lt Cornp<1ny
SET: II
PROJECT ADDRESS: 2003 Costa Del Mar Rd.
PROJECT NAME: Condo Remodel
ifAPPLICANT t JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted:;20.rpD(b~
Mail Telephone Fax In Person
0 REMARKS:
By: Richard Moreno
EsGil
1/30/2020
Telephone#:
Email:
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 12/23/2019
JURISDICTION: Carlsbad
PLAN CHECK#.: cbR2019-3497
✓• EsG1I
A SAFFbuilrCornpany
SET: I
PROJECT ADDRESS: 2003 Costa Del Mar Rd.
PROJECT NAME: Condo Remodel
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
C8J The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
C8J The applicant's copy of the check list has been sent to:
George Brown
D EsGil staff did not advise the applicant that the plan check has been completed.
C8J EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: George Brown Telephone#: 858-449-9379
Date contacted: (by: ) Email: georgeb@galleryhomedesign.net
Mail Telephone Fax In Person
0 REMARKS:
By: Richard Moreno
EsGil
12/12/2019
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad cbR2019-3497
12/23/2019
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: cbR2019-3497 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2003 Costa Del Mar Rd.
FLOOR AREA:
Remodel: 878 sq-ft
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 12/23/2019
FOREWORD (PLEASE READ):
STORIES: no change
HEIGHT: no change
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 12/12/2019
PLAN REVIEWER: Richard Moreno
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy\ where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad cbR2019-3497
12/23/2019
PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring IWQ corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. Indicate on the Title Sheet of the plans the name of the legal owner and name of
the person responsible for the preparation of the plans. Section R 106.1.1.
3. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
4. Some of the information provided on plans is not legible.
s. Plans: For small building projects, 11" X 17" will be accepted as long as the
detail is sufficient and readable. Be consistent; don't mix sizes of drawings
(exception: maps for recording). Do not attach information with clips, tape, or
staples.
6. Lettering on sheets must never be less than 1/8-inch in height.
7. Title Block --Put title information on all sheets except the cover sheet. Provide
the following: project name, drawing title, sheet number and revision column,
project address, and name, address and phone number of the preparer.
8. Drawing Quality --The drawing should be easy to read, with all lines and letters
dark enough to provide good contrast with the paper. Brown line prints, pencil
drawings (including corrections or alterations), and microfilm copies of plans
cannot be accepted.
Carlsbad cbR2019-3497
12/23/2019
9. Scale --Be consistent and indicate your scale using a bar symbol ( for plan
reproduction integrity). All site drawings are to be in a scale of 1" = 10', 1" = 20',
or 1" = 30'. Plats, short plats and boundary line adjustments may be drawn at a
smaller scale, such as 1" = 50', 1" = 60', or 1" = 100'. Architectural building plans
and elevations are to be 1 /8" = 1' or 1 /4" = 1 ', with 1 /6" = 1' or 1 /20" = 1' for larger
structures.
10. Vicinity Map --include on the site plan. The vicinity map covers the project site
and surrounding streets and property within a minimum of 600' of the site.
Copies of a city map can be made from the Street Atlas in the self help area of
the permit center.
11. Show locations of permanently wired smoke alarms with battery backup, per
Section R314:
a)
b)
c)
Inside each bedroom.
Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
Such smoke alarm locations shall comply with the following:
i) They shall be not less than 3' from the door opening of a bathroom.
ii) They shall be at least 20' from a cooking appliance.
iii) They shall be at least 3' from supply registers of heating/cooling
systems.
iv) They shall be at least 3' from the tip of the blade of a ceiling-
mounted fan.
• NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
12. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall be
provided with smoke alarms located as required for new dwellings; the smoke
alarms shall be interconnected and hard wired. Exception: Smoke alarms in
existing areas need not be interconnected and hard wired where the alterations
or repairs do not result in the removal of interior wall or ceiling finishes exposing
the structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R314.8.1.
13. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315:
a) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
Carlsbad cbR2019-3497
12/23/2019
• NOTE: When more than one carbon monoxide alarm is required to be
installed, the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
14. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
GENERAL RESIDENTIAL REQUIREMENTS
15. Clarify Kitchen enclosure shown on plans. Notice that access to the rest of the
Condo will be closed off.
16. Plans are not scaled to check for room area requirements.
17. Habitable rooms shall have a floor area of not less than 70 square feet. Section
R304.2.
18. Habitable rooms, except kitchens, shall not be less than 7' in any horizontal
dimension. Section R304.3
19. Sleeping rooms shall have a window or exterior door for emergency escape.
20.
Section R310.
a) Windows must have an openable area of at least 5.7 square feet, with the
minimum openable width 20" and the minimum openable height 24".
b) The bottom of the clear opening shall not exceed 44" above the floor.
Do not measure to the window sill. This generally applies to windows that
have a height of 3' or less. See the figure below to see the correct method
of measurement.
c) Such openings shall open directly into a public way or a court that opens
to a public way (4-sided courts are prohibited).
d) If such openings occur at a patio, the patio may not be enclosed.
Appendix H, Section AH103.2.
e) The emergency door or window shall be openable from the inside to
provide a full, clear opening without the use of any keys or tools.
All habitable rooms shall be provided with aggregate glazing area of not less than
8% of the floor area of such rooms, per Section R303.1.
Carlsbad cbR2019-3497
12/23/2019
21. Natural ventilation shall be provided for all habitable rooms, with the minimum
openable area to the outdoors of 4% of the floor area being ventilated. Section
R303.1.
22. Water closet compartments shall be provided with aggregate glazing area in
windows of not less than 3 square feet, one-half of which must be openable
(unless mechanical ventilation is provided). Section R303.3.
23. Bathrooms and powder rooms must be mechanically ventilated (an openable
window won't suffice). Section R303.3.1.
24. At least 1 /2 of the common wall must be open and have an opening not less than
25 sq. ft., nor one tenth of the floor area of the interior room, if light and
ventilation is being supplied from an adjacent room. Section R303.2.
25. Required glazed openings shall open directly onto a street or public alley, or a
yard or court located on the same lot as the building. Required glazed openings
may face into a roofed porch where the porch abuts a street, yard or court and
the longer side is at least 65% and the unobstructed the ceiling height is at least
7 feet. Section R303 .1
STRUCTURAL
26. Reference non-load bearing details to where they may pertain.
27. Not sure how drywall framing detail provided on plans pertains to this set of
plans.
28. Wall legend on plans is not consistent. All walls are shown as new walls. Please
clarify the location for new walls.
MECHANICAL
29. Show on the plans the location, type and size (Btu's) of all heating and cooling
appliances or systems.
30. Every dwelling unit shall be provided with heating facilities capable of maintaining
a room temperature of 68 degrees F at a location 3 feet above the floor and 2
feet from exterior walls in all habitable rooms. Show basis for compliance. CRC
303.9.
31. Detail the dryer exhaust duct design from the dryer to the exterior. The maximum
length is 14 feet with a maximum of two 90-degree elbows or provide the
manufacturer's duct length specification description on the plans: Include the
dryer specifications (manufacturer, model, and fuel type) as well as the duct
description (size and type). CMC Section 504.4.2.
Carlsbad cbR2019-3497
12/23/2019
32. Show how makeup air will be provided for the washer and dryer enclosure. The
code requires an opening with a minimum of 100 square inches of makeup air
(can be louvered door). CMG 504.4.1
ELECTRICAL
33. Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels. If the service is over 200
amperes, submit a single line diagram, panel schedules, and provide service
load calculations.
34. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom.
CEC 210.52(0).
35. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
36. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.12(A): Kitchens, laundry areas, family, living,
bedrooms, dining, halls, etc.
d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry
areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors,
within 6' of a sink, etc.
37. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be
either:
a) A 20 ampere circuit dedicated to each bathroom, or
b) At least one 20 ampere circuit supplying only bathroom receptacle outlets.
PLUMBING
38. Show the shower stall can accommodate a 30" circle and has a minimum floor
area of 1,024 sq. in. CPC Section 408.6.
39. Dimension on the plans the 30" clear width required for the water closet
compartment and the (minimum) 24" clearance required in front of the water
closet. CPC 402.5.
40. Provide a note on the plans: The control valves in showers, tub/showers,
bathtubs, and bidets must be pressure balanced or thermostatic mixing valves.
CPC Sections 408, 409, 410.
Carlsbad cbR2019-3497
12/23/2019
41. Specify on the plans: Water conserving fixtures: New water closets shall use no
more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8
GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8
GPM of flow. CPC Sections 407,408,411,412.
42. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
ENERGY CONSERVATION
43. All domestic hot water piping to have the following minimum insulation installed:
½" pipe (1/2" insulation);¾" pipe (1" insulation); 1" to 1-½" pipe (1-½"
insulation). CPC 609.11 & ES 150.0U)
a) Additionally, the ½" hot water pipe to the kitchen sink, and the cold water
pipe within 5' of the water heater both require 1" minimum insulation. ES
150.OU)
Residential Energy Lighting Requirements: ES 150.0(k)
44. All installed luminaires shall be high-efficacy in accordance with ES TABLE
150.0-A. Light sources that are not marked "JAB-2016-E" shall not be installed in
enclosed luminaires. ES 150.0(k)
45. In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire
shall be controlled by a vacancy sensor.
46. Dimmers or vacancy sensors shall control all LED style luminaires. Two
exceptions: Fixtures installed in hallways or (closets under 70 square feet).
47. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be
equipped with a standard medium base screw shell lamp holder. ES 150.0(k)
48. SFD outdoor lighting fixtures that are attached to a building are required to be
high efficacy, be manually on/off switch controlled, and have both motion sensor
and photocell control. See ES 150.0(k) 3 for additional control options.
Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2
49. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior.
Detail compliance by including a complying exhaust fan or a ducted range hood
to the exterior.
Carlsbad cbR2019-3497
12/23/2019
50. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior.
A bathroom is defined "as a room with a bathtub, shower, or spa or some similar
source of moisture".
51. Residential bathroom exhaust fans shall be energy star rated and shall be control
by a humidistat capable of an adjustment between 50 and 80% humidity.
CalGreen 4.506.1. Exception: Control by a humidistat is not required if the
bathroom exhaust fan is also the dwelling whole house ventilation.
a) All fans installed to meet all of the preceding ventilation requirements must
be specified at a noise rating of a maximum 1 "Sone" (continuous use) or
3 "Sone" (intermittent).
MISCELLANEOUS
52. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
53. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
54. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Richard Moreno at EsGil. Thank you.
Carlsbad cbR2019-3497
12/23/2019
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Richard Moreno
PLAN CHECK#.: cbR2019-3497
DATE: 12/23/2019
BUILDING ADDRESS: 2003 Costa Del Mar Rd.
BUILDING OCCUPANCY:
BUILDING I AREA
PORTION (Sq.FL)
Remodel 878
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdi~tion Code cb
:',";:i7
1997 UBC Buildin g Permit Fee •• 1··/i.r!'il:
1997 UBC Plan Check Fee
1 ·tUN:
Type of Review:
I Valuation
Multiplier
c~est.
By Ordinance
Reg. VALUE
Mod.
D Structural Only
D Repetitive Fee
'}.;ii> Repeats
'I)!>'
0 Complete Review
0 Other
□ Hotsly
EsGllF-
1------llHr. @.
Comments: . ..... . .•... l!i J~~itlen tQ tq/1l above fee, an additionalfee of.$
$ ·•·•·· fhr.).f()t lll/1l .Oal($'reen review.
($)
40,836
40,836
$226.781
is doe(. · hour@
Sheet 1 of 1