HomeMy WebLinkAbout2007 COSTA DEL MAR RD; ; CB122751; Permit03-22-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit PermitNo: CB122751 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2007 COSTA DEL MAR RD CBAD Tl Sub Type COMM 2162100700 Lot# 0 $95,844 00 Construction Type 5B Reference # LA COSTA 2582 SF REMODEL OF TENNIS SHOP TO INCLUDE EXERCISE AREA Applicant TOM MCCABE 2011 B SAN ELIJO AVE CARDIFF CA 92007 760-207-5720 Status ISSUED Applied 12/26/2012 Entered By JMA Plan Approved. 03/22/2013 Issued. 03/22/2013 Inspect Area Plan Check #: Owner THIRD LA COSTA HOMEOWNERS ASSN C/O MGMT HORIZONS 802 3RD ST OCEANSIDE CA 92054 Building Permit $676 02 Meter Size Add'l Building Permit Fee $0 00 Add'l Red. Water Con Fee $0 00 Plan Ctieck $473 21 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $20 13 PFF (3105540) $0 00 Park Fee $0 00 PFF (4305540) $0 00 LFM Fee $0 00 License Tax (3104193) $0 00 Bridge Fee $0.00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0 00 PLUMBING TOTAL $0 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $67 00 Other Building Fee $0 00 MECHANICAL TOTAL $40 25 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot. Water Con Fee $0 00 Redev Parking Fee $0 00 Red Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $1 00 HMP Fee ?? Fire Expedidted Plan Review $295 00 Green Bldg Standards Plan Chk 99 TOTAL PERMIT FEES $1,572 61 Total Fees $1,572.61 Total Payments To Date $1,572 61 Balance Due: $0.00 Inspector' FINALAPPROVAL Date. Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen'ed to as "fees/exactions" You have 90 days from the date this perniit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previouslv been oiven a NOTICE similar to this, or as to which the statute of limitations has previouslv othenvise expired THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE. •PLANNING IZlENGINEERING •BUILDING •FIRE •HEALTH •HAZMAT/APCD ^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www.carlsbadca.gov Plan Check No. C&j'Z' Z^S] Est. Value Tfk ^ST^'-f ^ Plan Ck. Deposit Pate (^/^ I VZ- ISWPPF JOB ADDRESS ZCO^ CP$.ltr PCL/»^ fo^ SUiTE#/SPACE#/UNIT» I I CONSTR TYPE I OCC GROUP CT/PROJECT # # BATHROOMS TIENANT BUSINESS NAME DESCRIPTION OF WORK Include Square Feet of Affected Areafs) n^E IBBOPOSED USET \ EXISTING USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES|~|# NOj I AIR CONDITIONING YESp^NOl I FIRE SPRINKLERS YEggjNOQ APPLICANTNAME (Primary Contact) ADDRESS •2^ lib l^\.)oA:^ OpPUC/SyrNAm (Secfj/rdary Contact) CITY- / 1 , STATE ZIP CITY 0/^\!r^ STATE ZIP STATE PHONE FAX PHONE 7^6 :re-5 0 CONTRACTOR BUS. NAME AD(3fiESS ADDRESS STATE CITY STATE ZIP PHONE PHONE EMAIL ARCH/DESIGNER NAME & ADDRESS CLASS CITY BUS L1C# (Sec 7031 5 Business and Professions Code Any City or County which requires a permitto construct, alter, improve, denriolish or repair any structure, prior to its issuance, also requires the applicantfor such permitto file a signed statement that he is licensed pursuantto the provisions ofthe Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 ofthe Business and Professions Code) or tnat he is exempt therefrom, and the basis for the alleged exemption Any violation of Section '7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaration / hereby affirm underpenalty of perjury one of the following declarations • I have and will maintain a certificate of consent to self-msure for workers' compensation as provided by Section 3700 of the Uibor Code, for the performance of the work for which tfiis permit is issued • I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the perfomiance of the work for which this permit is issued My workers' compensation insurance camer^and-policy"' number are Insurance Co Policy No Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less I I Certificate of Exemption-1 certify that in the perfomiance of the work for «*ich this perniit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attomey's fees. JS^ CONTRACTOR SIGNATURE • AGENT DATE SOW NER -BUI L D E R D E t L ARATI OJM / hereby affirm that I am exempt from Contractor's bcense Law for the follomng reason I I I, as ovmer of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale-Jf, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) sa!e-JI I -Tli as 01 1, as owner of the property, am exclusively contracting with licensed contractors to constmct the project (Sec 7044, Business and Professions Code The Contractors License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I I I am exempt under Section _ eBusiness and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement QYes I INO 2 I (have / have not) signed an application for a building permit for the proposed work 3 1 have contracted with the following person (firni) to provide the proposed constaiction (include name address / phone / coniractors' license number) 4 I plan to provide portions of the wort(, but I have hired Ihe following person to coordinate, supen/ise and provide the major wori( (include name / address / phone / contractors' license number) 5 I will provide some of the work, but 1 have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of wori() (7^1 'ROPERTY OWNER SIGNATURE •AGENT DATE .3' '2 ^ - Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 Presley-Tanner Hazardous Substance Account AcP Yes No Is the applicant or future building occupant required to obtain a pemiit trom the air pollution control distnct or air quality management disti icP Yes No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site' Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 1 hereby atfirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certify that I have read the application and state thatthe above inlomiation is conect and that the infbrmaton on the plans is accuiate. I agree to comply with all City ordinances and State laws relating to building constmcbon 1 heieby authonze repiBsentatve of the City of Carlsbad to enter upon the above mentioned property for inspecton purposes 1 ALSO AGl^E TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CriY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0' deep and demolition or construction of stmctures over 3 stones in height EXPIF!AT10N Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within 180 days from the date of such pemiit onf the buikiing or workVuthonzed by such permit is suspended or abandoned at any time after the work s commenced for a penod of 180 days (Section 106 4 4 Unrtbrm Building Code) ^^TAPPLICANT'S SIGNATURE k / \ zT---^ DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. OF OCCUPAWCY (Commerc icil Projects Only Fax (760) 602-8560, Email buildina(S)carlsbadca gov or Mail the completed fomi to City of Carisbad, Building Division 1635 Faraday Avenue, Carisbad, California 92008 C0#: (Offlce Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS STATE CITY STATE Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS LIC No DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAIL / FAX TO OTHER: ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ygf APPLICANT'S SIGNATURE DATE Inspection List Permit#: CBI22751 Date Inspection Item 06/18/2013 89 Final Combo 06/17/2013 89 Final Combo 06/17/2013 89 Final Combo 03/28/2013 84 Rough Combo Type: Tl COMM Inspector Act PD AP Rl PD AP PD AP LA COSTA: 2582 SF REMODEL OF TENNIS SHOP TO INCLUDE EXERCISE A Comments Wednesday, June 19, 2013 Page 1 of 1 «!•> ^T^^ INSPECTION RECORD 121 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB 121 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION SI FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbaclca.qov/BuHdinq AND CUCK ON "Request Inspection" DATE: vS/^fS CB122751 2007 COSTA DEL MAR RD LA COSTA 2582 SF REMODEL OF TENNIS SHOP TO INCLUDE EXERCISE AREA Tl COMM . Lot# TOM MCCABE ' RECORD COPY IF "YES" IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FlNAL BUILDING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 760-602-8560. EMAIL TO BLDGlNSPECTIONS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE.. CARLSBAD. CA 92008. BUILDING INSPECTORS CAN BE REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR INSPECTION. YES Required fbr Building Final If Clieclced YES Date Inspector Notes f Planning/ Landscape 760-944-8463 Allow 48 hours / CM&I (Engineering Inspections) 760-438-3891 Cali before 2 pm J Fire Prevention 760-602-4660 Allow 48 iiours Type of Inspection CODE # BUILDING Date #11 FOUNDATION Inspector Type of Inspection # ELECTRICAL #31 •ELECTRICUNDERGROUND DUFER Date Inspector #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 • ELECTRIC SERVICE • TEMPORARY • GROUT •WALL DRAINS #35 PHOTOVOLTAIC #10 TILTPANEIS #11 POURSntlPS #11 COLUMN FOOTINGS #39 FINAL CODE n MECHANICAL #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME •FLOOR •CEILING #44 • DUCT & PLENUM • REF. PIPING #15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #49 FINAL CODE « COMBO INSPECTION #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRVWALL #82 DRYWALL,EXT1ATH, GASTES(17,18,23) #51 POOLEXCA/STEEl/BONO/FENCE #83 ROOFSHEATING, EXTSHEAR (13,15) #55 PREPLASTER #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL CODE # PLUMBING #22 • SEWER & BL/CO •Pl/CO #89 HNAL0CCUPANCY(19,29,39,49) Date #21 UNDERGROUND •WASTE • WTR Inspector FIRE Date Inspector #24 TOPOUT •WASTE OWTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 •GASTEST •GASPIPING A/S UNDERGROUND FLUSH #25 WATERHEATER A/S OVERHEAD VISUAL #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL CODE # STORM WATER #600 PRE-CONSTRUCnONMEEnNG ysnNAL F/AROUGH-IN F/A HNAL #603 FOLLOW UP INSPECTION FIXED EXnNGUISHING SYSTEM ROUGH-IN #605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICEOFVIOLATION MEDICAL GAS PRESSURETEST #610 VERBALWARNING MEDICAL GAS RNAL REV 10/2012 SEE BACK FOR SPECIAL NOTES EsGil Corporation In (Partners/iip witH government for (Building Safety DATE: 3/15/13 • AEELJCANT JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-2751 SET III PROJECT ADDRESS: 2007 Costa Del Mar Rd PROJECT NAME: La Costa Resort and Spa Tennis Shop - TI XI The plans transmitted herewith have been corrected where necessary and substantially connply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 3/11/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partners/tip witti government for (ButCding Safety DATE: 2/11/13 Uj/ppucmi yJS JURIS JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.- 12-2751 SET II PROJECT ADDRESS: 2007 Costa Del Mar Rd PROJECT NAME La Costa Resort and Spa Tennis Shop - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. xl The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Tom McCabe 2011B San Elijo Ave, Cardiff, CA 92007 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IX EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted. Tom McCabe (Victor) Telephone #: 760-207-5720 Date contacted: (by: ) Email: vsalcido@mccabearch.com Fax #: Mail Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 2/4/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 12-2751 2/11/13 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 9. Please provide the required LTG-5C form for the new track lighting. The lighting plans on sheet M-E-1 still show the installation of new track lighting, please correct the LTG forms or remove the track lighting. 10. Please provide panel schedules, indicate new and existing loads. Please indicate on the plans the location ofthe electrical panel and detail the required working clearance. Please a single line diagram to show conduit and conductor size for the new panel shown as B-1. 13. Please provide the MECH-3-C forms showing the required mechanical ventilation rates for the new or revised conditioned spaces. Coordinate the mechanical and the Title 24 outside air design. CMC 403.0 & Title 24 121(b)2 & (d). No MECH- 3-0 form was provided to show the increase in the required outside air. 14. Please provide a completed "City of Carlsbad Special Inspection Agreement". No form provided. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad 12-2751 2/11/13 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In (Partners/iip witR government for (BuiCdtng Safety DATE: 1/7/13 • APPLICANT ^,;2<JURIS JURISDICTION: City of Carlsbad * • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-2751 SET. I PROJECT ADDRESS: 2007 Costa Del Mar Rd PROJECT NAME: La Costa Resort and Spa Tennis Shop - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: Tom McCabe 201 IB San Elijo Ave, Cardiff, CA 92007 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. X EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Tom McCabe Telephone #: 760-207-5720 Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By. Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 12/28/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 12-2751 1/7/13 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 12-2751 JURISDICTION: City ofCarlsbad OCCUPANCY: B USE: Exercise Room/ Retail TYPE OF CONSTRUCTION: VB ACTUAL AREA: 2582sf ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: Yes OCCUPANT LOAD: 57 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/26/12 DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/28/12 DATE INITIAL PLAN REVIEW COMPLETED: 1/7/13 PLAN REVIEIWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. City of Carlsbad 12-2751 1/7/13 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Please provide a statement on the Title Sheet of the plans to show compliance with the current Codes. The following are the correct current Codes: a) The 2010 edition of the California Building Code (CBC) adopts the 2009 International Building Code (IBC) and the 2010 California Amendments. b) The 2010 edition of the California Electrical Code (CEC) adopts the 2008 National Electrical Code (NEC) and the 2008 California Amendments. c) The 2010 edition of the California Mechanical Code (CMC) adopts the 2009 Uniform Mechanical Code (UMC) and the 2009 California Amendments. d) The 2010 edition of the California Plumbing Code (CPC) adopts the 2009 Uniform Plumbing Code (UPC) and the 2009 California Amendments. e) The 2010 edition of the California Fire Code (CFC) adopts the 2009 Uniform Fire Code (UFC) and the 2007 California Amendments. f) The 2008 edition of the California Energy Efficiency Standards. Provide a section view of the new soffits. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top to the structure and lateral bracing. c) Show height of the soffit from floor, soffit to roof framing or floor framing. City of Carlsbad 12-2751 1/7/13 4. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F complywith ASCE 7-05 Section 13.5.6.2.1 as follows: a) All ceilings shall use a Heavy Duty T-bar grid system. 5. Please provide the required LTG-1 C forms. 6. Please have the document author and the principle designer ofthe LTG-1 C form sign the imprinted document. 7. Please complete the LTG-1-C part 3 of 4 mandatory automatic controls portion ofthe LTG-1-C forms. 8. Please have the principle designer check the appropriate box(s) and complete the Statement of Compliance System Acceptance section ofthe LTG-1-C part 4 of 4 documents. 9. Please provide the required LTG-5C form for the new track lighting. 10. Please provide panel schedules, indicate new and existing loads. Please indicate on the plans the location ofthe electrical panel and detail the required working clearance. 11. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. 12. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing duct work; please note or show mechanical ventilation will be provided capable of supplying the minimum rate of outside air required per minute per occupant as shown in Table 4-1 of the UMC. 13. Please provide the MECH-3-C forms showing the required mechanical ventilation rates for the new or revised conditioned spaces. Coordinate the mechanical and the Title 24 outside air design. CMC 403.0 & Title 24 121(b)2 & (d). 14. Please provide a completed "City of Carlsbad Special Inspection Agreement". To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad 12-2751 1/7/13 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 12-2751 1/7/13 [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 12-2751 PREPARED BY: Doug Moody DATE: 1/7/13 BUILDING ADDRESS: 2007 Costa Del Mar Rd BUILDING OCCUPANCY: M/B TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA (Sq.Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl 2582 37.12 95,844 Air Conditioning Fire Sprinklers TOTAL VALUE 95,844 Junsdction Code cb By Ordinance Bldg Permit Fee by Ordinance $676.02 Plan Check Fee by Ordinance Type of Review QRepetitve Fee ~ Repeats |V] Complete Review • Other |--| Hourly EsGil Fee • Structural Only Hr. @ $439.41 $378.57 Comments: Sheet 1 of 1 macvalue doc + ^ CITY OF PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE:01/02/13 PROJECT NAME: LA COSTA RESORT PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2007 COSTA DEL MAR RD VALUATION: $95,844 PROJECT ID: CB 12-2751 APN: 216-123-03 /1 This plan check review is complete and has been APPROVED by the ENGINEERING XJ Division. By: KATHLEEN LAWRENCE 01/02/13 A Final Inspection by the Division is required LJYes [7]NO [ 1 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on L„ ^ J the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: TIVICCABE@MCCABEARCH.COM Vou may a/so have corrections from one or more ofthe divisions listed below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on tiie attaclied ciiecl<list please contact the following reviewer as marked: :.Pl:ANNING||||:.,;^;v fWP-' !'':^'''''''7.60'-T602-2756'|; ¥:^-iv,: 'd'-iSiri ".ii.f,l"-' .'.•:i^ 'j' ' -a-;-'- -;';e. • %S,.F-'if$.*¥J m- ,'-4760.6p2t4B65,\*#»f ! ^ Chris Sexton ^ - ' 760-602-4624 Chris.Sexton@carlsbadca.gov 1 /) Kathleen Lawrence LV J 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan I J 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz f—J 760-602-4675 Gina.Ruiz@carlsbadca.gov 1" 1 Linda Ontiveros L^-j 760-602-2773 Linda.Ontlveros@carlsbadca.gov 11 Cindy Wong ' 760-602-4662 Cvnthia.Wong@carlsbadca.gov 1 ' 1 I Dominic Fieri L. .^j 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: Development Services Land Development Engineering 1635 Faraday Avenue BUILDING PLANCHECK Development Services Land Development Engineering 1635 Faraday Avenue ^ CITY OF CHECKLIST Development Services Land Development Engineering 1635 Faraday Avenue CARLSBAD QUICK-CHECK/APPROVAL 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for CB 12-2751 Project Address 2007 COSTA DEL MAR RD Project Description REMODEL EXISTING RETAIL BLDG Date 01/02/13 APN 216-123-03 Valuation $95,844 ENGINEERING Contact Kathleen LawrencG Phone 760-602-2741 • RESIDENTIAL INTERIOR • RESIDENTIAL ADDITION MINOR (<$20,000.00) • CARLSBAD PREMIER OUTLETS • OTHER: MOHO Email kathleen.lawrence@carlsbadca.gov Fax- 760-602-1052 [Zl TENANT IMPROVEMENT • PLAZA CAMINO REAL COMPLETE OFFICE BUILDING OFFICIAL USE ONLY , ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: KATHLEEN LAWRENCE REMARKS: NO ADDITIONAL ENG. FEES DATE:01/02/13 Notificiation of Engineering APPROVAL has been sent to viaiiXlL V''"^' , ' • • • on OVQlin .E-36 Page 1 of 1 REV 4/30/11 ^ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www carlsbadca sov DATE: 12-27-12 PROJECT NAIVIE: PROJECTID: PLAN CHECK NO: CB 12-2751 SET#: 1 ADDRESS: 2007 Costa Del Mar Rd APN: 216-120-03,04, 05 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: tmccabe@mccabearch.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING - 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • 1 Dominic Fieri 760-602-4664 Dominlc.Fieri@carlsbadca.gov Remarks: ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov " DATE: 3/20/13 PROJECT NAIVIE: La Costa Ti PROJEC'^^ PLAN CHECK NO: cbl22751 SET#: III ADDRESS: 2007^sta del mar rd APN: ^ This plan check review is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required ^ Yes • No •I This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: tmccabe@mccabearch.com (and via usps) Vou may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 76(^602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.sov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Grefiorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov X Cindy Wong 760-602-4662 CYnthia.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.fiov Remarks: 3/20/2013 **APPROVED: Page 1 of2 THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. *** Bubble all Changes *** Sheet A2.1:90 minute egress light fixture in legend. Where are they on the plans both reflected ceiling and electrical sheets? Place them considering equipment layout. They shall meet the following requirements The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than i-foot candle at the walking surface. CFC 1006 Page 2 of 2 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 03-20-2013 Reviewed by: Name: TOM MCCABE Address: 2011 B SAN ELIJO AVE CARDIFF CA 92007 Permit #: CBI22751 Job Name: LA COSTA: 2582 SF REMODEL OF Job Address: 2007 COSTA DEL MAR RD CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office caimot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0006089 [NOT MET] *** Bubble all Changes *** Sheet A2.1 : 90 minute egress light fixture in legend. Where are they on the plans both reflected ceiling and electrical sheets? Place them considering equipment layout. They shall meet the following requirements The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumina.tion level shall not be less than 1-foot candle at the walking surface. CFC 1006 Entry: 02/15/2013 By: cwong Action: CO Cond: CON0006170 [MET] **APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 03/20/2013 By: cwong Action: AP BLDG. DEPT COPY P^g^^^f^ CONDITIONAL RECOMMENDATION FOR APPROVAL CONDITIONS OVER THE COUNTER CORRECTIONS ARE NECESSARY FOR RECOMMENDATION FOR APPROVAL A2.1 Reflected Ceiling Plan Add the following Note A photometric plan of all occupied areas, that demonstrates compliance with CBC 1006, will be provided upon request by Deputy Fire Marshal Greg Ryan (760-602-^1665). M-E-1 Lighting Plan Coordinate means of egress illumination locations with A2 1 Reflected Ceiling Plan Daryl K. James & Associates, Inc. Checked by: Daryl Kit James 205 Co//na Terrace Date: Februarv 1, 2012 Ws*a, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Tom McCabe / Victor Salcido JURISDICTION: Carlsbad Fire Department PROJECT NAME: Retail/Gym PROJECT ADDRESS: 2007 Costa Del Mar Road PROJECT DESCRIPTION: CB122751 2,582w Remodel first floor or existing retail building Electncal modifications and mechanical ductwork only. This plan was reviewed in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. CORRECTIONS PLEASE ADDRESS ALL REMAINING COMMENTS SHOWN IN BLUE FONT OVER THE COUNTER IS • Project Description Electrical and mechanical modifications are proposed for this project Please provide electrical and mechanical plans Sheet Index Revise Sheet E-6 to E-5 • Building Code Provide the Following List of Applicable Codes 2010 California Building Code . .. .based on the 2009 International Building Code 2010 California Fire Code based on the 2009 International Fire Code 2010 California Electrical Code . based on the 2008 National Electncal Code 2010 California Mechanical Code ...based on the 2009 Uniform Mechanical Code 2010 California Plumbing Code based on the 2009 Uniform Plumbing Code 2010 California Energy Code •Deferred Submittals Add list of deferred submittals Fire Sprinkler System 2010 CFC 903 and 2010 NFPA 13. Fire Alarm System 2010 CFC 907 and 2010 NFPA 72 •GN CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 2/15/13 PROJECTNAME: La Costa Tl PROJECTID: PLAN CHECK NO: cbl^751 SET#: I ADDRESS: 2007 costa del >-y I rrd APN: Q This plan check review is complete and has been APPR0VE6.^^he fire Division. O By: cwong A Final Inspection by the Division is required ^ Yes • No 3 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: tmccabe@mccabearch.com (and via usps) Vou may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.fiov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.fiov 1 1 Greg Ryan 760-602-4663 Grefiorv.Ryan@carlsbadca.fiov 1 1 Gina Ruiz 760-602-4675 Qina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.fiov X Cindy Wong 760-602-4662 Cynthja.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: *** Bubble all Changes *** Page 1 of 2 Sheet A2.1:90 minute egress light fixture in legend. Where are they on the plans both reflected ceiling and electrical sheets? Place them considering equipment layout. They shall meet the following requirements The means of egress, including the exit discharge, shall be illuminated at all times the space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1-foot candle at the walking surface. CFC 1006 Page 2 of 2 CORRECTION LIST BLDG. DEPT eOPY Daryl K. James & Associates, Inc 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Checked by: Daryl Kit James Date: December 27, 2012 APPLICANT: Tom McCabe PROJECT NAME: Retail/Gym JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2007 Costa Del Mar Road PROJECT DESCRIPTION: CB122751 2,582 [J Remodel first floor or existing retail building. Electrical modifications and mechanical duct work only This plan was reviewed in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. RESUBMITTAL INSTRUCTIONS TO AVOID DELAY IN EXPEDITED RECHECK SERVICES • Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates. • Provide a written response following each comment, On This Correction List, explaining how and where each plan review comment has been addressed. • Provide a copy of Building Department (EsGil) comments. Input fire revisions onto the Building Dept. plan check. • Please direct any questions regarding this review to: Daryl K. James 760-724-7001 or kitfire(gsbcglobal.net • COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS TO AVOID DELAY: DARYL K. JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 CORRECTIONS IS Project Description Electrical and mechanical modifications are proposed for this project. Please provide electrical and mechanical plans. Building Code Provide the Following List of Applicable Codes 2010 California Building Code 2010 California Fire Code . 2010 California Electrical Code 2010 California Mechanical Code 2010 California Plumbing Code 2010 California Energy Code based on the 2009 International Building Code based on the 2009 International Fire Code based on the 2008 National Electncal Code based on the 2009 Uniform Mechanical Code based on the 2009 Uniform Plumbing Code Page 2 of 2 Deferred Submittals Add list of deferred submittals Fire Spnnkler System 2010 CFC 903 and 2010 NFPA 13 Fire Alarm System 2010 CFC 907 and 2010 NFPA 72 GN Exiting Note 5 Revise the reference to CBC 1013 4 to 1011 5 3 of the CBC Note 7 Revise the reference to CBC 108 1 8 to CBC 1008 1 9 3 Note 8 Revise the sign text to read, This Door To Remain Unlocked When Building is Qccupied Doors / Windows & Hardware Note 12. Revise note and reference in accordance with the 2010 edition ofthe CBC Fire Protection Note 3 Add CFC 906 Note 11. Revise to CFC Chapter 14 NotelS Revise reference from 708 ofthe UBC to 717 3 ofthe CBC A2.1 Door General Notes Note 3 Add . without the use of a key or special knowledge or effort All doors are shown to be equipped with key locks. General Notes Note 8 Add, The means of egress, including the exit discharge, shall be illuminated at all times the building space served by means of egress is occupied with a level not less than 1 foot-candle at the walking surface Legend Provide a symbol for means of egress illumination that provides not less than 1 foot-candle at the walking surface. Reflected Ceiling Plan Denote means of egress illumination that provides not less than 1 foot-candle at the walking surface Floor Plan Denote fire extinguisher locations End of Comments STRUCTURAL CALCULATIONS LA COSTA RESORT & SPA TENNIS SHOP REMODEL CARLSBAD. CA Prepared For: RECEIVED DEC 26 2012 CITY OF CARLSBAD BUILDING DIVISION LA COSTA RESORT CO, MEG Project No.: 1257 Date Issued: Revision Dates: Prepared By: MCNEFF ENGINEERING & CONSULTING A PROFESSIONAL CORPORATION 1991 VILLAGE PARK WAY SUrTE 115 ENCINITAS, CA 92024 T (760) 479-9838 F (760) 479-9837 www.nncneffengineering.corn MCNEFF ENGINEERING & CONSULTING RHFPTWn 1 CIF A PROFESSIONAL CORPORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 CAtCOLATEDBY nan= l2-hll2. A PROFESSIONAL CORPORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 CHEOCEDBY Tel: (760) 479-9838 • Fax: (760) 479-9837 1 i > oi ! •> \J OA 0 G Tf P ol d I >Ki\ ^ \ n" IT' [T DO R (2--') 2. G '1 i-fli 1. \ ^ u D .<^. a.( 2." 3 Ti li."^ 7 3 V AW ^^\•^ id •^•) 2 M 2. u ^1 '^1 TpT)c 2 •OT AL r \J .g 3d 6ft f?ti jK)|rT \' YA k UU iL^i •a 0 5 10 .0 j. V U 1 lA\^ % ^(^ T p ^1 1 1 ;u 6B \^ Al^ (a C4 2 % OA i»\(< HP a P -M 1^ ^. X ^. 9C 1. t \\^ ro" *' It. • p 1 > L ,00 U • 1. p" ( \V ki p6 e \o |) f 1 ^ AV( t L OA i_ X 4 e M) C 6ii • 1 '•> \ •?* mi* >PA 1^ 6ii • 1 • 1 \.c ; < \ - 1.4 , 1 0 f ^ h He U -•5 r n f no <^ s 1.2 ?U j)l p.' iiAr 5 ^ = c —jj^. 1 (A t eo \" AP f f \ %5 I. MCNEFF ENGINEERING & CONSULTING A PROFESSIONAL CORPORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 Tel: (760) 479-9838 • Fax: (760) 479-9837 SHEET NO . OF. CALCUUTED BY_ CHECKED BY SCALE DATE. DATE- 1 i DL=; •^ei 1 ! L= \0.'b 'AT- ll ..,___L__ J.' i I : • ; 1 I ^ >^ 1 ^ „^ L_^_. --.J j R= mt LL= I t 1 -I ! I 1= 4s?vi<j'l 1 t i 1 J. -AF" I -W T-LL=-i--|Y^n--n^L=^5^ ™,—J—,—,— N4* I J I !_ ! ! .i i. I 1 MA=, 1.^ ..l4-Zio4 1= \T^U^ B DL= AT= I LL= - - TL= L= M=- t W= R= VA= MCNEFF ENGINEERING & CONSULTING 1^51 A PROFESSIONAL CORPORATION 1991 Village Park Way. Suite 115 Encinitas. CA 92024 Tel: (760) 479-9838 • Fax: (760) 479-9837 SH^NO.. OF- CAIJCULATED BY_ CHECKED BY SCA1£ DATE- DATE. At <ii2jb\x)V lAL. Df if EL to mjfJii, Ml OS HO 1 6 Hi? ILi:i 2\ 11 1. 1- Tom, TOTM, MJ Hi- (3 vJ»tV 0 - IP = te * 5n +^6 3MO MCNEFF ENGINEERING & CONSULTING A PROFESSIONAL CORPORATION 1991 Village Park Way. Suite 115 -Encinitas, CA92024 Tel: (760) 479-9838 • Fax: (760) 479-9837 JOB. SHEET NO.. 0F_ 4 CAIJCULATEO BY_ CHECKED BY DATE. DATE. 1! m \A31 •—' ^" 1 1 A - 1 f ^ 1 u - '< ^ J c 5ni fcA 1 r 1,12 f I ' 1: r H I' i VJ S A< 1 0, 2- / P( r •2, 1 / / , , ^' I pr ::>C-K ^1 ' 1 i>cl r' * r /» > '-hi ) w ll ^ i t -'J • DO i 6-6 >\ W TA PC ,* 4 v —?*• TJ . <\ ?c KI b'l It 'bu dtl- ( '=\ J Vc r* 1 I /is A 1. \ -T -; I n\ •7 1 L T A'^ 'I )• > OZ r c V/ / IP la 1^ M-k f J 1 \\£^ 1, 1 11 r f r h Wi F L \ m feo K1 . \ m • i . 1 ktl •« he ^' = n n D Ml r I r= ^7 0 7 tic 1 Jt 1 ne ^ H ?-« 'P -i FA r An U )AL K 1 ; ? -V-v 1 • 5, 1 ' 0 c IS 1 \ 1 >/ PI K. ^ 2 p=--J . f- 'I I L /. > • '1 • tt y .[ u 4^ k 4^ 1 T=>i|- • 1 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG-1 C Project Name La Costa Resort Tennis Shop Remodel Date 1/24/2013 Project Address 2100 Costa Del Mar Rd Carlsbad Climate Zone Total Cond Floor Area 2,582 Unconditioned Floor Area 0 GENERAL INFORMATION Building Type: Nonresidential High-Rise Residential Hotel/Motel Guest Room School Relocatable Public School Conditioned Spaces Unconditioned Spaces Phase of Construction: New Construction Addition Alteration Method of Compliance. Complete Building Area Category Tailored Documentation Author's Declaration Statement I certify that this Certificate of Compliance documentation is accurate and complete. Name IVIark Gallant, CEPE Signature >7 Jye*^ Company Date Gallant Energy Consulting 1/24/2013 Address 508 W Mission Ave Ste 201 CEA# CEPE# City/Sfafe/Zip Phone Escondido, CA 92025 760-743-5408 The Principal Lighting Designer's Declaration Statement I am eligible under Division 3 ofthe California Business and Professional Code to accept responsibility for the lighting design. This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24, Pages 1 and 6 of the California Code of Ftegulations. The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 0 Name Thomas A McCabe Signature Company Phone McCabe Architecture 760-479-0735 Address License # 2051 San Elijo Ave City/State/Zip Date Cardiff, CA 92007 Lighting Mandatory Measures Indicate location on building plans of Mandatory Measures Note Btock LIGHTING COMPLIANCE FORMS & WORKSHEETS (check box if worksheets is included) For detailed instructions on the use of this and ail Energy Efficiency Standards compliance forms, piease refer to the Nonresidential Manual published by the California Energy Commission ^ LTG-1 C Pages 1 through 4 Certificate of Compliance Aii Pages required on plans for all submittals LTG-2C Lighting Controls Credit Worksheet LTG-3C Indoor Lighting Power Allowance LTG-4C Pages 1 through 4 Tailored Method Worksheet LTG-5C Pages 1 and 2 Line Voltage Track Lighting Worksheet EnergyPro 5 1 by EnergySoft User Number 2875 RunCode: 2013-01-24T13:09:t>3 ID Page 1of6 CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG-1 C Project Name j Date La Costa Resort Tennis Shop Remodel 1/24/2013 INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Installation Certificate, LTG-1 - INST (Retain a copy and venfy form is completed and signed ) Field Inspector Certificate of Acceptance, LrG-2A and LTG-3A (Retain a copy and verify form is completed and signed ) Field Inspector A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power listed on this Lighting Schedule Is only for: ^ CONDITIONED SPACE UNCONDITIONED SPACE ! ^ The actual indoor lighting power listed below includes all Installed permanent and portable lighting systems in accordance with §146(a) Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be Included in the V calculation of actual indoor lighting power density in accordance with the Exception to §146(a) Wll portable lighting in excess of 0 2 watts per square foot is totaled below Luminaire (Type, Lamps, Ballasts) Installed i Watts A B C D E i F G H None or item Tag Complete Luminaire Descnption^ (i e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballasts) Watts per Luminaire^ How wattage j Was determined Number of Luminaires installed Watts (D X F) Field Inspector^ None or item Tag Complete Luminaire Descnption^ (i e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballasts) Watts per Luminaire^ CEC Default From NAS According _To__§130 (d.or.e).. Number of Luminaires installed Watts (D X F) Pass <o u. A A can 16w fluor 16 0 • 26 416 B B2X2RT5 1475 20 0 6 120 C C PENDAN7 40WINCAN 40 0 4 160 D D FLUOR 2S75 2 2875 28 0 ^ i 17 476 E EELM-809-WMR16 WW 10 0 5 50 F FEXI7LED2W 20 v* ; 1 2 i 1 i \ 1 : ; Installed Watts Page Total: 1,224 Building total number of pages: Installed Watts Building Total (Sum of all pages) 1,224 Building total number of pages: Enter into LTG-1 C Page 4 of 4 1,224 1 Wattage shall be determined according to Section 130 (d and e) Wattage shall be rating of light fixture, not rating of bulb 2 If Fail then descnbe on Page 2 of the Inspection Checklist Form and take appropriate action to correct Venfy buiiding plans if necessary EnergyPro 5 1 by EnergySoft User Number 2875 RunCode: 2013-01-24713:09:53 ID' Page 2 of 6 CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG-1 C Project Name La Costa Resort Tennis Shop Remodel Date 1/24/2013 INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit areas > 250 ft^, automatic daylighting controls for daylit areas > 2,500 ft^, d) shut-off controls, e) display lighting controls, f) tailored lighting controls - general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic controls for retail stores > 50,000 ft , in accordance with Section 131 MANDATORY LIGHTING CONTROLS - FIELD INSPECTION ENERGY CHECKLIST Field Inspector Type/ Description Number of Units Location in Buiiding Special Features Pass Fail Motion Sensor Ail Entire Space SPECIAL FEATURES INSPECTION CHECKLIST (See Page 2 of 4 of LTG-1 C) The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the speciai justification and documentation submitted Field Inspector's Notes or Discrepancies: EnergyPro 51 by EnergySoft User Number 2875 RunCode: 2013-01-24713:09:53 ID Page 3 of 6 CERTIFICATE OF COMPLIANCE (Part 4 Of 4) LTG-1 C Project Name j La Costa Resort Tennis Shop Remodel ; Date 1/24/2013 CONDITIONED AND UNCONDITIONED SPACE LIGHTING MUST NOT BE COMBINED FOR COMPLIANCE Indoor Lighting Power for Conditioned Spaces indoor Lighting Power for Unconditioned Spaces Watts 1 Watts Installed Lighting (from Conditioned LTG-1 C, Page 2) ^224 Installed Lighting (from Unconditioned LTG-1 C, Page 2) 0 Lighting Control Credit Conditioned Spaces (from LTG-2C) 0 Lighting Control Credit ' Unconditioned Spaces (from LTG-2C) 0 Adjustedlnstalled _ Lighting Power 1,224 Adjustedlnstalled _ Lighting Power 0 Complies if Installed! Allowed ! Complies if Installed! Allowed : I Allowed Lighting Power Conditioned Spaces (from LTG-3C or PERF-1) 2,917 Allowed Lighting Power Unconditioned Spaces (from LTGr3C) 0 Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans Listed below is the acceptance test for the Lighting system, LTG-2A and LTG-3A. The designer is required to check the acceptance tests and list all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance If aii the lighting systern or control of a certain type requires a test, list the different lighting and the number of systems The NA7 Section in the Appendix ofthe Nonresidential Reference Appendices Manual descnbes the test Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropnately Forms can be grouped by type of Luminaire controlled. Enforcement Agency: Systems Acceptance Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controls is installed in the buiiding or space shall be certified as meeting the Acceptance Requirements. The LTG-2A and LTG-3A forms are not considered complete forms and are not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) of Title 24 Part 6 The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy A copy of the LTG-2A and LTG-3A for each different lighting luminaire controi(s) must be provided to the owner of the building for their records ' 1 Luminaires Controlled LTG-2Aand LTG-3A Equipment Requinng Testing Descnption Number of Luminaires controlled Location Controls and Sensors and Automatic Daylighting Controls Acceptance Motion Sensor All Entire Space i 1 ! ; ! ' ! ! ! ! ! ! ! ! ! i ! ] ! ! 1 EnergyPro 5 1 by EnergySoft UserNumber 2875 RunCode: 2013-01-24713:09:53 ID. Page 4 of 6 INDOOR LIGHTING POWER ALLOWANCE LTG-3C Project Name La Costa Resort Tennis Shop Remodel Date 1/24/2013 ALLOWED LIGHTING POWER (Chose One Method) A Separate LTG-3C must be filled out for Conditioned and Unconditioned Spaces Indoor Lighting Power Allowances listed on this page are only for «/ CONDITIONED SPACES UNCONDITIONED SPACES COMPLETE BUILDING METHOD BUILDING CATEGORY (From §146 Table 146-E) WATTS PER (ft^) X COIMPLETE BLDG. AREA ALLOWED WATTS X X X X X X X X X X X X X X X TOTALS AREA WATTS AREA CATEGORY METHOD BUILDING CATEGORY (From §146 Table 146-F) WATTS PER (ft^) X Area ft^ ALLOWED WATTS Exercise, Gymnasium 1 00 X 1,874 1,874 Retail Sales, Wholesale 1 60 X 529 846 Office <= 250 sqft 1 10 X 179 197 X X X X X X X X X X X TOTALS 2,582 2,917 AREA WATTS TAILORED METHOD Total Allowed Watts using the Tailored Method taken from LTG-4C (Page 1 of 4) Row 3 0 The indoor lighting power allowance using the Tailored Method of compliance shall be determined using the LTG-4C set of forms A separate set of LTG- 4C forms shall be filled out for CONDITIONED and UNCONDITIONED spaces EnergyPro 51 by EnergySoft User Number 2875 RunCode: 2013-01-24713:09:53 ID: Page 5 of 6 LIGHTING MANDATORY MEASURES: NONRESIDENTIAL LTG-MM Project Name La Costa Resort Tennis Shop Remodel Date 1/24/2013 Indoor Lighting Measures: §131(d): Shut-off Controls For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting Overnde for Building Lighting Shut-off The automatic buiiding shut-off system is provided iwith a manual, accessible override switch in sight of the lights The area of override is not to exceed 5,000 square feet §119(h)-Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer j §111: Fluorescent Ballast and Luminaires Certified: Aii fluorescent fixtures specified for the project are certified and listed in th Directory All installed fixtures shall be certified j §131 (a)' individual Room/Area Controls Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor-to-ceiling walls j Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0 8 watts §131(b): per square foot of iighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room ! §131(c): Daylight Area Control All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch, or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans §131(c)' Display Lighting Display iighting shall be separately switched on circuits that are 20 amps or less.6. Outdoor Lighting Measures: §130(c)1 • Mandatory lighting power determination for medium base sockets without permanently installed ballasts §132(a) All permanentiy installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumens per Watt or are controlled by a motion sensor | §132(b): All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements | §132(c)1: All permanentiy installed outdoor lighting meets the control requirements listed. , Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi-Level Lighting Requirements ^^•^"^^^i listed i EnergyPro 5 1 by EnergySoft User Number 2875 RunCode: 2013-01-24713:09:53 ID Page 6 of 6 MAXILUiyiE ELM-809 HALOGEN EMERGENCY LIGHT Catalog Number Type Project Nome. Dote FEATURES This fixture is an excellent choice when an attractive emergency light IS required In cases of AC power loss, it provides a minimum of 90 minutes illumination A trouble-free lead-calcium batter/ is provided with the fixture The lamp heads may be adjusted through the full range of motion because of the special swivel- track design. BODY • The thermoplastic housing of the product makes it corrosion-proof and scratch-and impact-resistant • UV-stabilization prevents discoloration of the product • Comparfments shaped by injection • Power may be supplied via wall or ceiling FACE • Beveled injection molded face with two round lamp heads molded into sloped side surfaces of fixture Each head holds a 5 watt covered MR 16 lamp MOUNTING • Unique "snap-together" universal mounting design permits top and back mounting Necessar/ hardware and canopy are provided ELECTRICAL • 120V or 277V input • Reset IS automatic • Hassle-free wiring without the need for additional hardware LAMPS • Beveled face with (2) 5 Watt MR 16 lamp heads BAUER Y • 6V, 4 amp-hour lead calcium battery works during power failures • Replaceable and requires no maintenance • When completely charged, supplies emergency power for 90 minutes • Indicator light shows high charge and readiness for operation TESTING • Test button • Solid state line latched low voltage disconnect to avoid deep discharge • Safeguarded against short circuits • Power IS automatically interrupted in cases of brown-out LISTED • ETL • Damp location approved Description: ELM-809 TYPE HOUSING COLOR CATALOG # HOUSING COLOR CANOPY ELM-809 • W-White Universal mount to wall or ceiling ELM-809 • B-Black Universal mount to wall or ceiling MAXI LU ME www.maxilume.com • Tel: 1-877-375-5555 • Fax: 1-877-375-3333 Iixitstorc ^ exit and emergency specialisis PRODUCT OVERVIEW The EXIT Series Thermoplastic Exit Signs feature an attractive low profile design. Ideal for commercial & institutional installations, the slim profile of this sign blends perfectly W\\h current interior decors. The EXIT series uses high-output red or green LED technology. This truly "universal" exit sign, comes standard with two (2) stencils, one (1) bacl< plate and a canopy. AC only and Self-Powered versions are available. The EXIT series meets Energy Star requirements. EXTERNAL SPECIFICATIONS EXIT series is constructed from durable corrosion and flame resistant thermoplastic. The EXIT series comes standard with a mounting canopy, two (2) stencils, one (1) back plate, removable chevrons and all mounting hardware. The EXIT series comes standard finished in white; optional black finish is available. A damp location rating is standard on all EXIT series products. An external LED status indicator and test switch is standard on all self-powered models. INTERNAL SPECIFICATIONS AC ONLY: standard 120/277VAC input SELF-POWERED: standard 120/277VAC input, self- powered versions use sealed nickel-cadmium batteries to provide a minimum 90 minutes of emergency duration. Electronic cut-off circuit prevents over discharge. EXIT Thermoplastic Universal liKdoor Arch tectural Exits EXIT DIMENSIONS _l 7 5" 1 • J \U \A . ORDERING INFORMATION DESCRIPTION: EXIT, thermoplastic exit, self-powered, red LED Series LED Color Housing Model Options 1 5" TES-EXIT I ) ! 1 •1 TES-EXIT • R (red) • G (green) W (White) B (Black) • AC (AC only) . BB (self-powered) . 2CK (dual-circuit) EXAMPLE: TES-EXIT-RW-BB I I Toll Free 866.471.2849 fax 310.256 3289 www fheexitslore.com 5ales@theexilstore com theexitstore.com sales@theexitstore.co m f5) loll Free 866.471.2849 MODERN DESIGN The low profile design of the EXIT series exit provides a clean, attractive and affordable solution. The durable thermoplastic housing is corrosion and flame resistant. The EXIT series stencils include removable chevrons that allow for easy "in the field" installation decisions. The modern and efficient design of the EXIT series allows for wall, ceiling or end mounting. Canopy and all installation hardware is included. ELECTRICAL SPECIFICATIONS The EXIT senes is configured with high-output LED lamps. LED version is standard with 120/277VAC input. RED LED -4 Watts GREEN LED -2 Watts MECHANICAL SPECIFICATIONS The EXIT series is constructed of durable corrosion and flame resistant thermoplastic. Field removable directional chevron arrows are standard. The EXIT series can be universally mounted single or double face. Canopy and mounting hardware are included. High- output LED technology provides energy savings, long life and even illumination levels. 120/277VAC input, maintenance free, sealed Nickel Cadmium bdtteries ore protected by an electronic cut-off circuit that prevents over discharge. External test switch and monitor LED are standard on BB versions. INSTALLATION EXIT series exit signs are suitable for surface ceiling, wall and end mounting. Suitable for indoor and damp location installations on normally inflammable surfaces. SELF-POWERED VERSIONS The EXIT-BB self-powered series is designed to operate on battery power in the event of a regular / moms power failure. Both the batter/ and charger ore completely contained within the standard enclosure. There ore no external components and no alterations made to the external dimensions of the standard sign. The EXIT-BB self-powered series utilize a solid state transformer technology that eliminates the possibility of relay failure due to particle build up on the relay. Status is easily determined via on LED that indicates AC-ON. A push button Thermoplastic Universal test switch allows maintenance personnel to quickly confirm the operational status of the exit on AC foil. BATTERY TECHNOLOGY The EXIT series is designed with a maintenance free, sealed Nickel-Cadmium battery providing a minimum emergency duration of 90 minutes. Recharge time of the battery is twenty-tour (24) hours. The maximum battery working temperature is 50 C. CODE & STANDARDS COMPLIANCE UL924 Listed, Damp Locations. FEATURES & SPECIFICATIONS INTENDED USE — 2RT5 IS designed for applications that require the extremely energy efficient delivery of comfortablevolumetriclightfromalay-infixturethatisappealingandshallowindepth Ideal for offices, schools, hospitals.retailandnumerousothercommeraalapplications Certainalrbornecontaminanbcandiniinish integrity of acrylic. Click here for Acrylic invironmental ComDatibiiitv table for suitable uses. OPTICAL SYSTEM — Delivers volumetric lighting by filling the entire volume of space with light, delivering the ideal amount of light to walls, cubicles, work surfaces and people Luminous characteristics are carefully managed at high angles, providing just enough intensity to deliver the volumetric effect Regressed, two-piece refractive system obscures and softens the lamp and smoothly washes the reflector with light linearfaceted reflertor softensand distnbutes light into the space and minimizes the luminance ratio between the fixture and the ceiling Mechanical cut-off across the reflertor and fresnel refrartion along the refractor provide high angle shielding and a quiet ceiling Sloped endplates provide a balanced fixture to ceiling ratio while enhancing the perception of fixture depth CONSTRUCTION — Impact modified acrylic prismatic refractor with polymer light diffusing film Rugged, one-piece, cold-rolled steel reflector with embossed facets with coated polyester powder paint after fabncation Rigid structure with ballast box and endplates End plates feature integral T-bar clips Fixtures may be mounted end-to-end ELECTRICAL SYSTEM — Highly efficient program start electronic ballasts. Class P, thermally proterted, resetting, HPF, non PCB, UL Listed, CSA Certified, sound rated A F14T5 uses GEB115, producing 122 ballast factor standard for typical applications F24T5H0 is available for higher ceiling applications Bi-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance SS option available for use with SIMPLY5™ Lighting Intelligence system with multi-level dimming See SYNERGY" Control Systems specification sheets for more information MAINTENANCE — Side mounted ballast tray accessed by removing adjacent ceiling tile Ballast tray may be removed from fixture during service Lamps accessed by squeezing refractor to release from retention tabs LISTING —UL Listed (standard) Optional Canada CSA or cUL Mexico NOM WARRANTY — 1-year limited warranty Complete warranty terms located at www acuitybrands com/CustomerResources/Terms_and_conditions aspx Protected by one or more of US Patents Nos 7,229,192,0541,467,0541,468,0544,633,0544,634,0544,992, 0544,933 and additional patent pending NOTE Specifications subject to change without nofice Catalog Number Type 2RT5 2'X2' 2 Lamps T5 SimPLYH UGHTING INTELLIGENCE Specifications Length 24(610) Width 24(610) Depth 3-1/8(7 9) 24 (61 0) 3-1/4 (8 4) All dimensions are inches (centimeters) unless otherwise specified ^ For shortest lead times, configure products using boided options Example 2RT514T5MV0LTGEB115LP835 2RT5 Series Lamp type Voltage Ballast Lamp' Options 2RT5 Recessed T5 14T5 14WT5(22") 24T5H0 24T5H0T5(22")' MVOLT' 347' GEB11S 115 ballast factor GEB11SS 115 ballast factor, step dimming GEBIOPS 1 0 ballast factor, programmed start' S5 095 ballast factor SIMPLY5 systen:!* LP835 3500°K LP830 3000°K LP841 4100°K GLR Internal fast-blow hise' PWS1836 6' prewire, 3/8" diameter, 18-gauge, 3-wire (n/a with GEB115S)' PWS1846 6' prewire, 3/8" diameter, 18-gauge, 4-wire' ELM Emergency battery pack' HW Hardware for SIMPL5™ system, replaces RELOC CSA Listed and labeled to comply with Canadian standards QFC_ Quick-flex cable' BDP Ballast disconnect plug (meets codes that require in-fixture disconnect) Notes 1 For TSHOuseGEBlOPS only, not available with 1415 2 MVOLKl 20-277 volts), 50-60HZ 3 For 347V use GEBIOPS ballast only 4 S1MPLY5 includes 13' S5 SSC REIOC* winng system, specify voltage unless HW {hardwire or PWS) is ordered 5 Required All fixtures shipped with lamps installed 6 Must spe( ify voltage, 120 or 277 7 For use with standard ballast 8 For use with step dimming ballast 9 See P5 MOOQD spec sheet for Et lumen output mformation FLUORESCENT 2RT5_2X2 2RT5 Volumetric Recessed Lighting 2' x 2' 2RT5 HTS GEB115, (2) FP24/841 lamps, 1220 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL14130 Coeffictents of Utilization pf 20% CP Summary pc 80% 70% 50% Zonal Lumen Summary 0° 90° pw 70% 50% 30% 50% 30% 10% 50%30%10% Zone 1 Lumens % Lamp % Fix 0° •776 776 0 103 103 103 101 101 101 96 96 96 0° - 30°, 603 24 7 28. 5° 778 770 1 95 91 87 89 86 83 85 83 80 0°-40°| 983 40.3 46 15° 749 751 2 86 79 74 78 73 68 75 70 66 0°-60°j 1716 70.3 81 25° 688 707 3 79 70 63 68 62 57 66 60 56 0° - 90° 2113 86 6 100 35° 583 638 72 62 54 61 54 48 59 53 48 90°-180° 0 00 OC 45° 443 557 05 ""6 66 55 48 54 47 42 53 46 41 0° -180° 2113 86 6 100 55° 293 473 05 ""6 61 50 42 49 42 37 47 41 36 65° 75° 167 73 319 114 7 8 57 53 45 41 38 34 44 41 37 34 32 29 43 40 37 33 32 29 Efficitency:86.6% 85° 11 9 9 49 38 31 37 31 26 36 30 26 LER:66J1 Ipw 90° 0 0 10 46 35 28 34 28 24 34 28 23 1 2RT5 24T5H0 GEBIOPS LP835, (2) FP24/835 lamps, 1760 lumens per lamp, s/m 1.2 (along) 1 3 (acrass), test no. IT112606 Coefficients of Utilization 100C 0° 90° pf 20% CP Summaiy pc 80% 70% 50% Zonal Lumen Summary 0° 90° pw 70% 50% 30% 50% 30% 10% 50%30%10% Zone 1 Lumens % Lamp % Fix 0° 1104 1104 0 102 102 102 100 100 100 96 96 96 0° - 30'! 871 24 7 28 5° 1098 1103 1 94 90 87 88 85 82 85 82 80 0°-401 1424 40 4 47 15° 1063 1088 2 86 79 73 77 72 68 74 70 66 0° - eO] 2484 70.6 82 25° 973 1037 3 78 70 63 68 62 57 66 60 56 0° - 901 3028 86 0 100 35° 826 939 72 62 54 61 54 48 58 53 48 90°-180° 0 0.0 OC 45°' 634 812 66 55 48 54 47 42 52 46 41 0°-180° 3028 86 0 100 55° 413 673 61 50 42 49 42 37 47 41 36 1 65° 75° 226 97 435 147 7 8 57 53 45 41 38 34 44 41 37 34 32 29 43 39 37 33 32 29 Efficiency: 86.0% 1 85° 13 14 9 49 38 31 37 31 26 36 30 26 LER. 56.0 Ipw 90° 0 0 10 46 35 28 34 28 24 34 28 23 1 •The LER (luminaire Efficacy Rating) is the lumens per watt rating for this fixture It is used to compare the energy efficiency of various products This photometnc report is based upon IES testing procedures, as stated in LM-41-1998 The reported lumen rating is based upon lamp manufacturer's published lumen output for the cold spot temperature measured dunng lamp calibration | Input Wattage TS/T8 Energy Comparison Wattage Ballast 1201^ 277^ 24T5H0 GEBIOP 55 54 14T5 GEB115S 39 39 14T5 GEB115S (50% step dimming) 22 22 System Lamp . Type Ballast t i -* •. Factor liiput , Wam^"''"'''i ,WattsSaved;, dmpafeatoWS 2-lampT8 F32T8U 0.88 58 _ 2RT5 2-lampT5 F14T5 1 22 39 19 An'McuityBrands Company FLUORESCENT One Lithonia Way Conyeis,GA 30012 Phone-8008587763 Fax 770-929-8789 wwwlithonia com 2RT5_2X2 ©2004-2012 Acuity Brands, inc All nghts reserved Rev 10/25/12 fA UTHONUBi LiGHriNG FEATURES & SPECIFICATIONS INTENDED USE The Surfece Volumetric™ series is designed for surface or suspend-mount applications that require the appealing aesthefics and high performance of voiumetnc lighfing Ideal fot offices, workrooms, retail and other commercial applicafions Available in 2 or 3-iamp, T5 or T8 configurations, this senes provides tremendous design flexibility Certain aitborne contaminants can dimmish mtegnty of acrylic Click here for Acrylic Environmental Compatibility table for suitable uses CONSTRUCTION Housing is roll formed fi'om code-gauge steel impact resistant 25% DR acrylic diffuser attaches to die cast ends by simple hook and pm design with controlled tension provided by sonically welded end plate, providing secure installafion and easy mamtenance Decorative die-cast end caps provide added durability Finish All metal parts are post-pamted in white polyester powder coat for smooth, finished edges and uniform light distnbufion. Natural aluminum finish available on end caps (see Opfions) Injection-molded plasfic light traps prevent light leaks between shielding and end plates and centers diffuser on channel OPTICS Volumetric illuminafion is achieved by creafing an optimal mix of light to vertical and horizontal work surfaces, rendering interior space, objects and occupants in a more balanced luminous environment Crescent-shape iinearfaceted refractor provides uniformlight distnbution andhighanglebnghtness control ELECTRICAL Thermally-protected, resetfing. Class P, HPF, non-PCB, UL Listed, CSA certified ballast is standard Luminaire IS suitable for damp locations AWM, TFN or THHN wire used throughout, rated for required temperatures UL/CSA listed ballast disconnect with stram relief and leads provided standard LISTINGS Ul listed to U S and Canadian safety standards Patents pending. WARRANTY 1-year limited warranty Complete warranty terms located at www acuitybrands com/CustomerResources/Terms_and_condifions aspx NOTE Specificafions subject to change without nofice Catalog Number Notes Type ST5-ST8 T5orT8 2or3-Lamp Specifications Length - T8 24 (61 0), 48 (121 9) or 96 (243 8) Length - T5 22-7/8 (58 1), 46-3/8 (117 8) or 92-5/8 (235 3) Width 10-1/8 (25 7) Depth 3-7/8(98) All dimensions are inches {centimeters} unless otherwise lead times will vary depending on options selected Consult with your sales representative noted Example: ST5 214T45 MVOLT GEBIOPS Series Numberof lamps Lamp type Voltage Ballast Options Finish" ST5 STB T5,2or 3-lamp T8,2or 3-lamp For tandem double- length unit, add prefix "T" Ex TST8 2 3 Not included 17 32 UTS 24T5H0 28T5 54T5HO 17WT8(24") 32WT8(48") 14WT5 (22-1/2")' 24r5H0 (22-1/2")' 28W 15(46-1/2") 54WT5H0 (46-1/2") 120 277 347 MVOLT GEBIOIS 88 ballast factor, instant start^ GEBIORS 88 ballast factor, program rapid start= GEB95 95 ballast factor* GEB95S .95 ballast factor, step dimming" GEB115 115 ballast factor' 6EB115S 115 ballast factor, step dimming'' GEBIOPS 10 ballast factor, program start" 1/3 One, three-lamp ballast EL Emergency battery pack (nominal 300 lumens)' ELM Emergency battery pack (nominal 1400 lumens)' LP Lamped, specify lamp type and color GLR Internal fast-blow fuse' GMF Internal slow-blow fuse' CSA Listed and labeled to comply with Canadian Standards SSR Specular silver interior finish (95% reflective) (blank) White ONA Natural aluminum Accessaries: Orc/eros separate catalog number STCR STACG_ STACGF_ STACGE_ Continuous row connector (see mounting data) ST adjustable aircraft cable gnpper suspension kit (specify length as 36 or 72 inches) (specify ceiling type Fl or F2 - see mounting data) ST adjustable aircraft cable gnpper with power feed (specify length as 36 or 72 inches) (specify ceiling type Fl or F2 - see mounhng data) ST adjustable aircraft cable gnpper with emergency power feed (specify length as 36 or 72 inches) (specify ceiling type Fl or F2 - see mounting data) Notes 1 Must use 1/3 ballast option 2 NOI available in 3-lamp configuration 3 Only available with T8 lamp types 4 Only available with T5 lamp types 5 Not available with 2' configuration 6 Must specify voltage 7 Die-cast end plates and light trap 8 For additional paint finishes refer to Architectural Colors FLUORESCENT ST5-ST8 ST5-ST8 T5/T8 Surface Volumetric MOUNTING DATA Suspension Kit Ceiling Types Fl for use with most T-bar and screw slot grid ceiling applications De- signed for on-gnd and off-grid installafions f2 for use with recessed or surface-mount horizontal J-box applications For unit or row installation, surface or suspend mounting Stem mounting not available on TST5 orTSTB Individual installafion — One double-stem (2' or 4' only) or two single-stem hangers required For aircraft cable, one STACG_, STACGF_, or STACGE_ required for each suspension point Row installation — Order one (1) STCR accessory per fixture for continuous row applications Not required for last fixture in row One hanger per fixture plus one per row required See ACCESSORIES below for hanging devices SQ DSH Note 1 2' configurations with emergency option cannot be stem mounted DIMENSIONS I A = l/4xl/2 ( 635xt27)OvalHole 0 = 11/16(1 74)Dia KO j B = l/4xl/2(635xl27)K0 E = 2(5 08)Dia KO and7/8(2 22)pia KO C = 7/8(222)Dia KO G = l-l/8(285)Dia KO i TTTjl'lll'l) j j pi ! 0 a ti y i 0 0 i. in ..I 111 01 l."l "'° 1 ^ 1 ol Q 1^ 0 CO ' 1 ' 1 M h "il I 1'.'! (s a 1 6 i V[ y 0 m Oj M 3VJ UU 1 1 isiai ! 13 n h (67) ~ 1 II.'! 0 0 , 'R ]4.6c 6 s 0 D y --f S! -i ] i*i A i( !> 1 0 .'OR A A , i(i,i[ y 0 Din ^ --IBC 11 F 0 1 ]i*A A i 1 ' i« 2 1 'i A ; iiJ.[ y 0 0 10 1 ^ y PHOTOMETRICS Calculated using the zonal cavity method in accordance with lESNA LM41 pmcedure Floor reflectances are 20% Lamp configurations shown are typical Full photometric data on ttiese and other configurations avail- able upon request 5T8 2 32 MVOLT GEBIOIS- test number LTL20265 ZONAL LUMEN SUMMARY COEFFICIENTS OF UTILIZATION -ZONAL CAVITY METHOD EFFEaiVE FLOOR CAVITY REFLECTANCE 20% 0-30 988 5 17 3% 21 1% 0-40 J.631 3 28 696 34 896 0-60 2 940 6 Sl 6% 62 8% 60-90 1,201 S 21 1% 25 6% 70-100 862 8 15 1% 18 4% 90-120 383 1 6 7% 8 2% 0-90 fl,l42 1 72 7% 88 4% 90-180 543 3 9 5% n 6% 0-180 4,685 5 82 2% 100% ST5 2 28T5 MVOLTGEBIOPS- test number LTL20253 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Lumtnaire RCC% 80 70 50 30 10 0 RW% 70 50 30 0. 70 50 30 Q, 50 30 20 SO 30 20 50 30 20 0. RCR 0 96 96 96 96 92 92 92 73 86 86 86 80 80 80 75 75 75 73 1 86 81 77 73 82 78 74 58 73 70 67 68 65 63 63 61 60 57 2 77 70 64 58 74 67 62 48 63 58 54 59 55 51 55 52 49 47 3 70 61 54 48 67 59 52 40 55 49 45 51 47 43 48 44 41 39 4 64 54 46 40 61 52 45 34 49 43 38 45 40 36 43 38 35 33 5 59 48 40 34 56 46 39 30 43 37 33 41 35 31 38 34 30 28 6 54 43 35 30 52 42 34 26 39 33 28 37 31 27 35 30 26 24 7 50 39 31 26 48 38 31 23 35 29 25 33 28 24 32 27 23 21 8 47 35 28 23 45 34 28 20 32 26 22 31 25 21 29 24 21 19 9 43 32 25 21 42 31 25 18 30 24 20 28 23 19 27 22 19 17 10 41 30 23 19 39 29 23 17 28 22 18 26 21 18 25 20 17 15 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFEaiVE FLOOR CAVITY REFLEaANCE 20% 0-30 1,066 6 20 5% 22 8% RW % Z2. 50. 20. fJ. 22. io. 22. 0 12. 22. 52. 20_ 2a. iSL 12. 20. 2. 1 0-40 1 ?49 5 33 6% 37 5% RCR 0 1 OS 1 05 1 05 1 OS 1 021 02 1 02 82 95 95 95 90 90 90 84 84 84 82 1 0-60 3,105 7 59 7% 66 5% J 94 89 85 81 91 87 83 66 81 78 75 76 74 71 72 70 68 65 60-90 1,157 5 22 3% 24 8% 2 85 77 71 65 82 75 69 55 70 65 61 66 62 58 62 59 56 54 70-100 78S 3 15 1% 16 8% 3 78 68 60 54 75 66 58 46 62 56 51 58 53 49 55 51 47 45 90-120 290 8 5 6% 6 2% 4 71 60 51 4S 68 58 SO 39 55 48 43 52 46 42 49 44 40 38 \ 5 6% 6 2% S 65 53 45 39 63 52 44 34 49 42 37 46 40 36 44 39 35 33 1 0-90 90-180 4,263 1 82'Mi 91 3% 6 60 48 40 34 58 47 39 30 44 37 32 42 36 31 40 35 31 28 0-90 90-180 406 7 7 8% 8 7% 7 56 43 35 30 54 42 35 27 40 33 29 38 32 28 36 31 27 25 0-180 4.669 8 89 8% 100% 8 52 39 32 26 50 38 31 24 37 30 25 35 29 25 33 28 24 22 1 9 48 36 29 24 47 35 28 22 34 27 23 32 26 22 31 26 22 20 1 10 45 33 26 21 44 33 26 20 31 25 21 30 24 20 29 23 20 18 1 An '^Acuit/Brands Company FLUORESCENT One Lithonia Way Conyers.GA 30012 Phone 800-315-4963 Fax 770-929-8789 www lithonia com ST5-ST8 ) 2D11-2G12 Acuity Brands Lighting, Inc All nghts resereed Rev 08/13/12 fA umaiSiM LiGHriNG FEATURES & SPECIFICATIONS INTENDED USE—The RTLED combines digital LED lighting and controls technologies with patented high- performance optical design to offer the most advanced luminaire for general-ambient lighting applications High-efficacy light engine delivers (ong life and excellent color, ensuring a superior quality lighfing installation that IS highly efficient and sustainable CONSTRUCTION — Rugged, one-piece cold-rolled steel reflector assembly with embossed facets Coated polyester powder-paint after fabncation Rigid structure with ballast box and end plates End plates mclude integral T-bar dips Impact-modified acrylic pnsmatic refractor with polymer light-diffusing film Luminaires may be mounted end-to-end and continuously wired OPTICS — Voiumetnc illuminafion is delivered by creating an optimal mix of light to walls, partitions, vertical and horizontal work surfaces — rendering the interior space, objects and occupants m a more balanced, complementary luminous environment Light distnbution is carefully confiolled at high angles, providing just enough luminous flux to create the volumetric effect Linear faceted reflector cavity softens and distributes light into the space while minimizing luminous contrast between the fixture and ceiling Regressed two-piece refractor system obscures and integrates individual LED images and uniformly washes the reflector cavity with light Sloped end plates provide a smooth, luminous transifion between fixture and ceiling while enhancing the perception of fixture depth ELECTRICAL—Long-life LEDs, coupled with high-efficiency drivers, provide superior quantify and quality of illumination for extended service life RTLED is rated to deliver L80 performance for 50,000 hours Standard nLight* embedded controls make each luminaire addressable - allowing it to digitally communicate with other nLightenabled controlssuch as dimmers, switches, occupancy sensors and photocontrols Simply connectall the nLight enabled control devicesandtheRTLEDluminairesusingstandardCat-5 cabling Unique plug-and-play convenience as devices and luminairesautomaficallydiscover each other and self-commission Lumen Management Unique lumen management system (opfion N80) provides onboard intelligence that artively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighfing Bi-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance LED AccuDrivedriver delivers full-range dimming from 0-lOV control signal Ballast disconnect provided where required to comply with US and Canadian codes INSTALLATION — Drivers and internal components accessed via plenum Driver tray may be removed from fixture during service Suitable for damp locafion Maintenance LED boards include plug-in connectors for easy replacement or senficing Catalog Number RECEIVED Notes Type g,']'y<^F CARLGBAD BUILDING D/V/s70N Volumetric Lighting 2RTLED 2'X2' LED DfJIGHUGHTJH /JS., CONSORTIUM • IttilGHT INDUSTRY RECOGNITION/AWARDS NGL'12 2012 RECOGNIZED PRODUCT pnouEss • t p • (t TheLED' 2011REST AMBIENT LED LUMINAIRE 2011 MOST INNOVATIVE OPTICAL CONTROL 2010 BEST INTERIOR LED PRODUCT LISTINGS — CSA Certified to meet U S and Canadian standards DEC Certified Tested to LM80 standards Protected byoneor moreof US Patent Nos 7,229,192,0541,467,0541,468,0544,633,0544,634,0544,992 0544,933 and addifional patents pending WARRANTY — 5-year limited warranty Complete warranty terms located at www acuitybrands com/CuslomerResources/Terms and conditions asox Note Specificafions subject to change without notice , Lead times will vary depending on options selected Consult with your sales representative Example: 2RTL233LD38 LP835I 2RTL2 Series Air function Lumens Voltage Wattage Color temperature Controls Options 2RTL2 Re- cessed 2X2 LED (blank) No air CAS Center air slots (air removal) 24L 2400 lumens' 33L 3300 lumens' (blank) MVOLT (120 •277V) 347 347V^ 024 24W='< 038 38W" LP835 82 CRI, 3500 Kelvin LP840 82 CRL 4000 Kelvin LP850 82 CRI, 5000 Kelvin NX Dimming, no nlight BLD Bi-level dimming N80 nLight with 80% (L80) lumen management N80EMG nLight with 80% (L80) lumen management for use with generator supply EM power NlOO nLight without lumen management NIOOEMG nLight without lumen management for use with generator supply £M power EL14L 1400 lumen battery pack nLight" Control Accessories: Orc/er os separate catalog number. Visit www sensorswitch com/nUght for complete listing ofnUght controls WallPod stations Model number Occupancy sensors Model number On/Off nPODM [color] Standard range 360°, ceiling (PIR/dual tech) nCM9/nCMPDT9 On/Off & Raise/Lower nPODM DX [color] Extended range 360°, ceiling (PIR/dual tech) nCMlO/nCMPOTIO Graphic Touchscreen nPOOGFX Wide view (PIR/dual tech) nWV16/nWVPDT16 Photocell controls Model number Cat-5 cabie bundles (plenum rated) Model number Continuous dimming nCMADC 10',CAT510FT CAT510FTJ1 On/Off & Dimming nCMPCADC 15',CA1515FT CAT515FTJ1 Accessories: Order as separate catalog number DGA22 Drywall ceiling adaptor, unit installation 1 Approximate lumen output 2 Not available with EL battery pack or BLD controls 3 Actual wattage may differ by +/- 5% when operating between 120-270V +1-10% 4 For use with 24L 5 For use with 33L LED 2RT1.ED-2X2 2RTLED Volumetric Recessed Lighting 2'x2' PHOTOMETRICS 2RTL2 33L D38 LP840,3,527 delivered lumens,test no. LTL 20070, tested in accordance to lESNA LM-79. 180° Coefficients of Utilization pf 20% ; CP Summary pc 80% 70% 50% Zonal Lumen Summary 0° 90 pw 70%50%30% 50%>30%10% 50%30%10% Zone Lumens % Lamp % Fixture 0" 1436 1436 0 119119 119 116 116 116 111 111 111 0°-30° 1081 30^6 30 6 5° 1432 1421 1 110105 101 103 99 96 99 96 93 0°-40° 1722 48l8 48 8 15° 1344 1375 2 100 92 86 90 84 79 87 82 78 0° - 60° 2898 82 2 82 2 25° 1157 1278 3 92 81 74 80 73 67 77 71 66 0° - 90° 3527 100 0 100 0 35° 887 1136 84 72 64 71 63 57 69 62 56 90°-180° 0 00 00 45° 633 963 ^< 77 65 56 64 56 49 62 54 49 0° - 180° 3527 100 0 i 100 0 55° 461 771 ^< 72 59 50 58 49 43 56 49 43 100 0 i 65° 300 515 1 66 53 45 52 44 39 51 44 38 1 75° 134 177 8 62 49 40 48 40 35 47 40 34 i 85° 19 11 9 58 45 37 44 37 31 43 36 31 1 90 0 0 10 54 41 34 41 33 28 40 33 28 Efficiency: 100.0% 0° 90° 2RTL2 33LD38LP835,3,313 180° delivered lumens,test no. LTL 20224, tested in accordance to lESNA LM-79. Coefficients of Utilization pf 20% CP Summary pc 80% 70% 50% Zonal Lumen Summary 0° 90 pw 70%50%30% 50%30%10% 50%30%10% Zone Lumens % Lamp % Fixture 0° 1350 1350 0 119119 119 116116 116 111111 111 0°-30° 1013 30 6 30 6 5° 1348 1344 1 110105 101 103 99 96 99 96 93 0°-40° 1611 48 6 48 6 15° 1263 1292 2 100 92 86 90 84 79 87 82 77 0°-60° 2718 82 ;o 82 0 25° 1091 1194 3 91 81 74 80 73 67 77 71 65 0°-90° 3313 100 0 100 0 35° 842 1054 84 72 64 71 63 57 69 62 56 90°-180° 0 0 0 0 0 45° 611 894 77 65 56 64 56 49 62 54 49 0°-180° 3313 1000 100 0 55° 443 721 72 59 50 58 49 43 56 48 43 65° 282 486 7 66 53 45 52 44 39 51 44 38 75° 127 172 8 62 49 40 48 40 35 47 39 34 85° 18 11 9 58 45 37 44 36 31 43 36 31 90 0 0 10 54 41 34 41 33 28 40 33 28 Efficiency: 100.0% 0 T5/T8 Energy Comparison to LED System Lamp Ballast Input Watts saved by type factor watts using LED LEO-NIOO LED 10 38 - LED-N80' LED 080 30 ~ Two-lamp T8 F32T8U 088 58 20 Two-lamp TS F24T5H0 10 54 16 RTLED with Air Handling 1 With nlight 80% lumen management input watts start at 30 and gradually increasing to 38 at 50,000 hrs when using 33L system 15 20 1 30 40 50 60 60 100 I AIR FLOW FWTE CFM Constant Lumen Management Enabled by the embedded nLight control, the RTLED actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life Referred to as lumen management, theis feature eliminates the energy waste created by the traditional practice of over-lighting Dimensions All dimensions are inches {centimeters} unless otherwise specified Without Lumen Management Energy is wasted and light level is inconsistent POWE t INPUT Wasted Energy THOUSAND OPERAllNG HOURS With Lumen IVIanagement Energy is saved and light level remains consistent Saved Energy ^^^^ llM!ii»llti!ilkJ THOUSAND 0PCRAT1NC3 HOURS 1 D 1 1 w Specifications Length,24 (61 0) Width 24 (61 0) Depth 3-1/8 (7 9) An "^^uityBrands Company LED One Lithonia Way Conyers.GA 30012 Phone 800-858-7763 Fax 770-929-8789 viiww lithonia com Phone 800-858-7763 ©2010-2012 Acuity Brands Lighting, Inc All rights reserved 2RTLED-2X2 Rev 09/10/12 GE Lighting spotlight The energy-efficient radiance of the GE energy smart® LED PAR30 short and long neck lamps is notjust something you see, It's something you feel GE energy smart® LED PAR30 short and long neck lamps For efficient, long-lasting options for traditional downlight applications, GE energy smart® dimmable 10-watt LED PAR30 lamps ore the perfect solution LOW-COST OPERATION: • Using only 12 watts of energy, save over $104 in energy costs over the rated life of a lamp versus a standard 50-watt halogen lamp based on $0 11 perkWh • Energy efficiency and long life mean fewer lamp replacements versus standard incandescent and halogen light sources EXCELLENT COLOR RENDERING • Available with a CRI of 80 to 92 COLOR TEMPERATURE • Halogen-like color • Available in 2700K, 3000K and WOOK LONG LIFE • Up to 30,000 hours rated life (L70) • Up to 50,000 hours rated life (L701 for dimmable version DIMMABLE • Dims from 100% to 10% BEAM PATTERNS • Available in 20° 24* 25', 35° and 40° beam patterns ENVIRONMENTALLY CONSCIOUS • These lamps are energy efficient, contain no lead or mercury, and ore compliant with matenal restnction requirements of RoHS GE QUALITY AND RELIABILITY • 3-year limited warronty ecomaginatlon' To learn n-iore about saving money and energy, go to: gelighting.com/ThinkLED When you Think LED lighting, Think GE imagination at work Information provided i5 subject lo change without notice Pleose verify all detoils with GE All values are design of typical values when measured under laboratory conditions and GE mokes no warranty or guarantee express or implied that such performance will be obtained under end-use conditions PERFORMANCE DATA GE energy smart* LED PAR30 short and long neck lamps CASE MOL LUMENS +RATED UFEIYRSI •RATED "ESTIMATED ENERGV UFE ENERGV STAR* SHAPE TVPE WATTS CODE DESCRIPTION VOLTS QTY" (INI INITIAL CBCP TEMP CRI 3HRS/DAV (HRS) COST/VR STATUS INFORMATION Ritall PAR30 -Dimming (Visual Comfort Lans^") 1 PAR30 MED 12 67922 LED12DP30R930/15 120 6 3 75 860 5900 3000 91 22 8 25,000 $145 1 • Accent, 15* Beam, Silver 67923 LEDi2DP3bR930V25 120 6 3 75 860 3400" 3000 "91 22 8 25,000 $145 'i • Accent, 25* Beam, Silver 67924 LED12OP30R930M0 120 6 375' 860 1500 3000 91 22 8 25,000 $145 Accent, 40* Beam, Silver 67925 LiDi2DP30R927/15 120 6 3^75 820 ' 5700 2700 91 22 8 25,000 $145 ' Accent, 15° Beam, Silver 67926 LEoi2OP30R927/25 120 6 3J5 820 3300 2700 91 22 8 25,000 $1 45 Accent, 25* Beam, Silver 67927 LED12DP30R927/40 120 6 3 75 820 1400 2700 91 22 8 25,000 $145 Accent, 40* Beam, Silver Compact PAR30 - Dimming (Concava Cover) PAR30 MED 12 65135 LEO12DP30S830/20 120 6 3 75 750 5100 3000 84 22 8 25,000 $145 • Accent, 20° Beam, Sliver 65136 LEDi7DP30S830/35 120 ~ 6" 3 75 750" 2050 3000 ' 84 '22 8 25,000 $145 •' Accent, 35* Beam, Sliver 65137 LED12DP30S827/20 120 6 375 740 SOOO 2700 83 22 8 25,000 $1 45 i • Accent, 20' Beam, Silver 65138 J.EM2DP3K827/35 120 6^ 375 740 2000 2700 83 22 8 25,000 $145 ; • Accentj^* Beam, Sijyer 65133 LED12DP30S/FL/TP 120 3 3 75 740 2000 2700 83 22 8 25,000 $1 45 : • Accent, 35° Beam, Silver 65985 TED12bP36s827725 120 6 375 740 3200 '2700 83 22 8' 25,000 $145 ' ir Accent, 25° Beam, Silver 65986 LED12DP30W827/2S 120 6 3_75 740 3200 2700 83 22 8 25,000 $145 Accent, 25* Beam, White 65987 LED12DP30B827/25 120 6 3 75 740 3200 2700 83^ 22 8 25.000 $145 ! • Accent, 25* Beam, Black 67256 LED12OP30S840/20 120 6 3 75 840 5800 4000 85 22 8 25,000 $145 Accent, 20° Beam, Silver 67257 LED12DP30S840/35 120 6 375 840 2600 4000 85 22 8 25,000 $145 ' • Accent, 35* Beam, Silver Compact PAR30 - Dimming (Convax Covtr) PAR30 MED 10 61922 LEO10OP30S83q/20 120 61923 LED10DP30S827/20 120 68013 _LED10DP30S827/35 120 64326 LEDWDM0W827/20 120 63026 LED10DP3/FL/TP 120 6 3 75 500 3720 3000 80 45 7 50,000 $120 • 6 3 75 450 3450 2700 80 45 7 50,000 $1^0 6 3 75 450 1240 2700 80 22 8 25,000 $120 6 3J5 450 3450 2700 80 457' 50,000 $1.26 • 3 3 75 450 1240 2700 80 22 8 25,000 $1 20 i • Accent, 20* Beam, Silver Accent, 20* Beam, Silver Accent, 35° Beam, Silver Accent, 20° Beam, Silver For additional product and application information, please consult GE's website gelighting.com/ThinkLED * The life roting is based on the hours of operation the lamp will provide before reaching 70% of its original lumen rating (L70I I ** Minimum order quantity = 6 ' • ENERGY STAR" quolified j ^ Estimated energy cost per year based on $0 11 per kWh energy rote and 3 operating hours per day ] Note Product descriptions ending in "TP" indicate a cord blister or clamshell package nested in a tray for shelf display ] Cords also designed for hook display ' ecomaginatiorr imagination at work Information provided is subject to chonge without notice Please verify all details with GE All values are design or typicol values when measured under laboratory conditions and GE mokes no warranty or guorantee express or implied thot such performance will be obtained under end-use conditions PERFORMANCE DATA GE energy smart* LED PAR30 short and long neck lamps •ULB BASE ORDER SHAPE TVPE WATTS CODE DESCRIPTION INITIAL +RATED "RATED "ESTIMATED ENERGV CASE MOL LUMENS COLOR LIFECVRS) LIFE ENERGV STAR* ADDITIONAL VOLTS <JTV" (INI INITIAL CBCP TEMP CRI 3HRS/6AV (HRS) COST/VR STATUS INFORMATION Rrtall PAR30 Long Ntck - Dimming (Visual Comfort L»nsf"| PAR30L MED 12 68387 LED12DP3LR930/15 120 6 4 75 860 5900 3000 91 22.8 25,000 $145 • Accent, 15° Beam, Silver 68388 LEpi2DP3LR930/2^ 120 6 4 75 860 3400 3000 91 22 8 25,000 $1 45 •"' Accent, 25* Beam, Silver _ 68389 LED12DP3LR930/40 120 6 860 1500 3000_ 91 22 8 25,000 $145 • Accent, 40* Beam, Sliver 683M JLEP12DP3LR927/15 120 6 820 5700. ^ 2700^ 9% - ?2 8 . 25,000 Accent, 15° Beam, Sijver 68391 LED12DP3LR927/25 120 6 4 75 820 3300 2700 91 22 8 25,000 $145 • Accent, 25* Beam, Sliver 68392 LED12DP3LR927/40 120 6 4 75 820 1400 2700 91 22 8 25,000 $145 • Accent, 40* beam. Sliver Compact PAR30 Long N»ck - Dimming (Concav* Cover) PAR30 MED 12 65139 LEO12DP3LS830/20 120 6 4 75 750 5100 3000 84 22 a 25,000 $145 • Accent, 20° Beam, Silver 65140 [ED12DP3L¥830/35^ 120 6 4 7? 750" 2050 3000 84 ^ 22 8 25,000 $145 • Accent, 35° Beam, Sliver 65141 LED12DP3LS827/20 120 6 4 75 740 5000 2700 83 22 a 25,000 $1 45 • Accent, 20° Beam, Sliver 65142 LEDi2DP3LS827/3S 6 4 75 740 2000 2700 83 22~8 ~ 25,000 Accent, 35* Beam, Silver 65134 LED12DP3LS/FLn'P 120 3 3 75 740 2000 2700 83 22 8 25,000 $145 • Accent, 35* Beam, Silver Compact PAR30 Long Ntck - Dimming (Convtx Covtr) PAR3p MED 10 61924 LED10OP3LS830/2q 120 6 4.75 500 3720 3000 80 45 7 50,000 $120 • Accent, 20° Beam, Silver 61925 LED10DP3LS827/20 120 6 4 75^ 450^ 3450 2700 80 45 7 50,000 $1 20 Accent, 20° Beam, Sliver 68014 LEpi0pP^LS827/35 120 6 4 75 450 1240 2700 80 22 B 25j0q0 $120 Accent, 35° BjBom, Sijver _ 63027 LED10DP3L/FL/TP 120 3 4 75 450 1240 2700 80 22 8 25,000 $1 20 • Accent, 35° Beam, Silver Compact PAR30 - Non-Dimming (Convex Cover) PAR30 MED 10 75376 LED10DP30/NFL/TP 120 3 3 75 340 1400 3000 82 27 4 30,000 $1.20 Accent, 24° Beam, Silver 75613 LED10DP30S830/24 120 6 3 75 340 1400 3000 82 27 4 30,000 $1 20 Accent, 24° Beam, Sliver 76144 LED10DP30S827/24 120 6 3 75 320 "1360 2700 82 ~ 27 4 30,000 $120 Accent, 24° Beam, Silver Compact PAR30 Long Neck - Non-Dimming IConutx Cover) PAR30L MED 10 75377 LED10DP30L/NFL/TP 120 3 4 75 340 1400 3000 82 27 4 30,000 $1 20 Accent, 24° Beam, Sliver 76145 LED10DP30LS827/24 120 6 4 75 320 1300 2700 82 27 4 30,000 $120 Accent, 24° Beam, Silver Retail Display Compact PAR30 Long Neck - Non-Dimming (High CRI -.OW Glare - Visual Comfort Lens'") _£AR30L MED 12 66050 LED12P3LS930/25 120 6 ^75 660 3j)qo 3000 92 22 8 25,000 $1^45 • Narrow Flood, 25° Beam, Silver 66051 LEO12P3LS930/40 120 6 4 75 660 950 3000 92 22 8 25,000 $145 • Flood, 40° Beam, Sliver ' 66052 LED12P3LS927/25 120 "6 4T5 ~ 630 3doo~ ~2700^ 92 22JEI 25,000 ~$r45 Narrow Flood, 25* Beam, Silver 66053 LEO12P3LS927M0 120 6 4 75 630 900 2700 92 22 8 25,000 $145 Flood, 40° Beam, Silver For odditiona) product and application informaiion, pleose consult GE's website gelighting.com/ThinkLED * The life roting is based on the hours of operation the lamp will provide before reaching 70% of its original lunnen rating (L70) ** Minimum order quantity = 6 * ENERGY STAR* qualified Estimated energy cost per year based on $011 per kWh energy rate and 3 operating hours per doy / Note Product descriptions ending in "TP" indicate a card blister or clamshell package nested in a tray for shelf display Cards also designed for hook display ecomagination" imagination at work Information provided is subject to change without notice Please verify all details with GE All values ore design or typical values when meosured under loborotory condjtjons ond GE mokes no worronty or guarontee, express onmplied thot such performonce will be obtoined under end-use conditions DESCRIPTION Two minimalistic looking low-voltage iamphoiders in two sizes for 35W IVIR11 and 50W MR16 lamps. Available in white, black or metallic silver finish. For Halo Linea surface and wireway channel systems. May also be used with Halo and Lazer Track systems with L2004 solid state adapter (12V lamps). Ideal for accent and display applications Use with Linea low voltage lighting systems operated at 12 or 24 volts. Catalog # Type Project Type Comments Type Prepared by Date SPECIFICATION FEATURES A Electrical Quick Lock Adapter Polycarbonate casing. Attaches electrically and mechanically anywhere along Linea surface channel. B Arm Perforated single-arm yoke allows lampholder to rotate 338° horizontally and provides ±90° vertical pivot for maximum aiming adjustability C Lamp Retention Spring Nickel-plated spring steel. Holds cover glass and lamp. D Die-formed Lampholder Body Steel gimbal ring. E Cover Glass Fixture provided with optional cover glass (required for use with non-open fixture rated lamps). Will accept one piece of media in place of cover glass. Grounding Low-voltage lighting systems do not require grounding when used with LV500 series isolated power supplies. Labels UL listed and CSA certified for use with Linea surface and wireway channel systems. LV303 STEEL GIMBAL LAMPHOLDERS Linea ORDERING INFORMATION SAMPLE NUMBER. LV304P Lampholders Finishes Accessories Lamps LV303 I LV3a4 P=Satin White MB=Matte Black SUSilver I (See Below) LV304 For use with 35WMR11 L =1 1/2- [38mnn! W=1 W [38mm] E =2 7/8" I73mm] For use with' up to SOW IVIR16 L =2-I51mm] W=2 1/8° |&»mmj E =3 3/i' [96mm! Accessones L100 Senes color filters, lenses and louver L1982MB Bam Door Shutters Z84=3SW Zffi=3SW Z23=35W Z24=35W Z86=35W Z87=35W ZSB^SOW Z89=<50W Z32=20W Z30=20W Z35=20W Z22=42W Z20=42W Z25^2W Z21=S0W Z26=S0W Z31=50W MR11G«10*Spot, 2W (VIR11 G4 30° Flood, 24V MRU G4 10° Spot, 12V MRU G4 40° Flood, 12V MR16G4 12° Spot, 24V MR16 G 4 40° Flood, 24V MR16 G4 12° Spot, 24V MR16G 4 40* Flood, 24V MR16VNSP, 12V MR16NSP, 12V MR16FI, 12V MR16VNSP, 12V MR16NSP, 12V MR16NFL, 12V MR16NSP, 12V MR16NFL, 12V MR16FL, 12V • ADV020813 9/04 TAB. Linea lampholders and Track Sheet 4 COOPER Lighting ACCESSORIES LV303 LV304 L100 Series 2"S0fnm UV and Color Filters For use with MR16 Lampholders. Make a powerful lighting statement by injecting soft or intense hues to accent any space. L112=Red Gel Filter L114=Ultraviolet, Dichoric Filter L120=Red, Dichoric Filter L121=Amber, Dichoric Filter L122=Yellow, Dichoric Filter L123=Green, Dichoric Filter L124=Daylight Blue, Dichoric Filter L125=Biue, Dichoric Filter L127=Cosmetic (2700°K), Dichoric Filter L130=Yeliow Gel Filter L131=Amber Gel Filter 11 L 2- .|yg. |51mm] [3mm) LIPO Series UV and Color Filters L100 Series Optical Lenses L110N=Diffuse Sandblasted Lens Provides an even beam spread from MR16 lamps—especially useful in wali washing. L111=Soft Focus Lens Smooths irregular beam pattern while maintaining high controlled illumination levels and beam angles of MR16 lamps L113=Prismatic Spread Lens Provides a symmetrical broadening of MR16 lamp beams Suitable when a wide, uniform light distribution is required. L115=Linear Spread Lens Fans out the MR16 beam 55° (27 1/2° to each side) to produce a wide rectangular pattern L110 till Ln3 L115 L100 Series Optical Lenses LV100 Series Louwer LV100MB=Expanded metal louver. Miniature black finished hexagonal-cell louver - controls light spill while retaining lamp optics. r^rV/V/^/VrfzT: ^^^^ x£CCCCO-XXX 2' (51mm) 1/8° Omm) L100 Series Louver L1982MB Barn Door Shutter L1982MB=Barn Door Shutter. Miniature black finished barn door shutters can be adjusted to control light beam. 2 1/2° J- (64mm) -| 1 3/8" (35mm) L1982 Barn Door Shutters COOPER Lighting Note Specifications and Dimensions subject to change without notice Viat our web site at www.cooperlighting.com Customer First Center ^^2^ Highway 74 South Peachtree City, GA 30269770 486.4800 FAX 770 486.4801 ADV020813 Cooper Lighting 5925 McLaughIm Rd. Mississauga, Ontario, Canada L5R 1B8 905 507.4000 FAX 905.568.7049 4 ts. CITY OF ARLSBAD PLUMBIWG, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Bufiding Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Project Address:2^:^5(A<)a-ftt^PpP«'-'^'rt^ 6g> \1{ Infonnation provided below refers to work being done on the aljove mentioned permit only. This form must be completed and returned to the Btiildinq Division before the periii!! tan be I'ssaed. Building Dept. Fax: (760) 602-85S8 Number of new or relocated fixtures, traps; or floor di:a!n$ i.,.,.. New building sewar line? ; Ves No Number of new roof drains? Install/alter water line?; M. Number of hew water heaters? Number of new, relocated or replaced gas outlets? iJA Number of new hose bibs? MB!! fell mi Residential Permits: New/expanded service: Number of new amps: — Minor Remodel on/sf; Ves No Commercial/lndMStrial: Tenant Improvement: Number of eirirting amps involved in this project: uC^C^ Number of new amps invoiced in tliis project: New-Construction: Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of hew furnaces, NO, or hedl pumps? ..j^ New or relocated duct worb? Ves ^ No Number of new fireplaces? Number of new exhaust fans? Relocate/install vent? ... Number of new exhaust hoods? Number of new boilers or compressors? , Number of HP B-18 Page 1 of 1 Rev; 03/09 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONN OFFICE USE ONLY UPFP# HV# BP DATE / Business Contact Telephone #' City ode„ Plan File# The following questions represent the facility's activities, NOT the specific project description. RART I: FIRE DEPARTMENT - HA2:ARD0US MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate-by- circling the item, whethgr your business will use, process, or store any oMhe following hazardous materials. If any of the items arg^'riele^ applicant must contact the Flre Prot^^ Agency with junsdlclion prior to plan submittai. Facllity's Square.Footage (including proposed project): />p Q f^- . Occupancy Rating: S^-^ 1. Explosive or Blasting Agents 5. Organic Peroxides 9 Water ReatUves 13. Corrosives 2 Compressed Gases 6. Oxidizers 10 Cryogenics IA Other Health Hazards 3 .Ffammable/Combuslitile Liquids 7. Pyrophoncs 11 Highly Toxic,or Toxic Materials Q^^None of Thes,e. 4 Flammable Solids 8. Unstable Reactives 12. (Radioactives, PART 11: SAN DIEGO COUNTY DEPARTIVIENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant musl contact the County of San Diego. Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 [irlor lo the issuance ofa'bullding permit Projecl Completion Date. / / Expected Date of Occupancy: / • GalARP Exempt I Date Initials • CalARP Required ±1 Date Initials • CalARP Complete 1 Date Initials FEES ARE REQUIRED. . NQ (for new 'construction or remodeling projects) Is your business listed on the.reverse side of this form' (check all that appiy). Will your business dispose of Hazardous Substances or IVIedical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal lo or. greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? WiH'your business store or handle Regulated Substances'(CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)' Will your business store petroleurn in tanks or containers at your facility 'witfi a' total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to'any of the questions tielow is yes, applicant must contact the Air Pollution Control Distnct (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to.the .issuance of a-building'or demolition permit Note- if the answer to questionSi4 or 5 is yes, applicant must also submit an asbestos notificalion form to the APCD.at least 10 working ,days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. Will the subject facility or construction activities include, operations "or equipment tliat emit or are capable of emitting anair contaminant (Seethe APCD faclslieet at htxo'llvjw/ sdapcd.orq/info/facts/Dermits pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any queslions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the.subject facility be located wittiin 1,000 feet of the outer boundary of a school (K through 12)'' (Search the California School Directory at http://www cde ca gov/re/sd/ for public and pnvate schools or contact the appropnate school district) Has a survey.been performed to deterinine the presence of Asbestos Containing Materials'' Will there be renovation that involves handling of any friable asbestos materials, or dislurtiing any malerial that contains non-friable asbestos'' Will there be demolition involving the removal of a load supporting structural member'' YES NO 1. • 2, • • 3 D 4. • 5. • Bnefly descnbe proposed project . * , > _ # SeTaest of my knowledge and belief the responses made herein are true and correct Signalure of Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION-. BY FOR OFFICIAL USE ONLY: DATE EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMrT BUT NOT FOROCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY~-HMD APCD COUNTY-HMD APCD HM-9171 (02/11) Goumy of San Diego'- DEH - Hazardous Matenals Division INDUSTRIAL WASTEWATER DISCHARGE PERMIT ^ ^ SCREENING SURVEY Date ^--U^SV , ^ A ^ Business Name street Address gCOg- (jQSt^ HAp mpTT^^^^ jA'. Email Address A(5^\M(to^VVV(XA|9Mvth ^Jm^ PLEAS'E CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECR TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Assembly Automotive Repair Battery 'IVIanufacturing Biofuel Manufacturing Biotech Laboratory Bulk Chemical Storage Car Wash Chemical Manufacituring Chemical Purification Dry Cleaning Electrical Component Manufacturing Fertilizer IVIanufacturing Film / X-ray Processing Food Processing Glass Manufacturing Industrial Laundry Ink Manufacturing Laboratory Machining / Milling Manufacturing Membrane Manufacturing (i.e. water filter membranes) Metal Casting / Forming Metal Fabrication Metal Finishing Electroplating Electroless plating Anodizing Coating (i.e. phosphating) Chemical Etching / Milling Printed Circuit" Board Manufacturing Metal Powders Forming Nutritional Supplement/ Vitamin Manufacturing Painting/'Finishing Paint Manufacturing Personal Care Products Manufacturing Pesticide Manufacturing / Packaging Pharmaceutical Manufacturing (including prectirsoris) Porcelain Enameling PowerGeneration Prin t .Shop Research and Development Rubber Manufacturing Semiconductor Manufacturing Soap / Detergent Manufacturing Waste Treatment / Storage SIC Code(s) (if known): Brief description of business activities (Production/Manufactunng Operations);, Description, of operations generating waste\A/ater (discharged to sewer; hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal/day): List hazardous wastes generated (type/volume): Date operation began/or will begin at this location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact Signature ENGINA WASTEWATER AUTHORITY, 62Q0 Avenida Encinas FAX: (760)476-9852 Phone No. --^'>>0 7^' ndnas Carisb^cX 92011 freo) 438-3941 CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Develooment Services Building Division 1635 Faraday Avenue 760-602-2719 u/ww.carlsbadca.gov In accordance with Chapter 17 ofthe Califomia Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. Project/Permit: Project Address:. A. THIS SECTION IWUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder • (If you checked as owner-builder you must also complete Section B of this agreement.) Name (Please printX Mailing Address. (Firsi) (Ml) (Last) aaress. am: QProperty Owner •Properly Owner's Agent of Record ""^rchitect of Record QEngineer of Record Email State of Califomia Registration NumbecL Expiration Date: AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws ofthe State of Califomia, that I have read, understand, ackpeflCtedge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, OOTStru ition mai|pnals testing and off-site fabrication of building components, as prescribed in the statement of special insp^iop nc ted pj^e qfpproved plans and, as required by the California Building Code. Signature; ted OvmQ approved plan Date- B. CONTRACTOR^ STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706;. This section must be completed by the contractor / builder / owner-builder. JX^^ Please check if you are Owner-Builder D Contractor's Company Name:. Name: (Please pnnt) C^I^H-Y Mailing Address Email Idress. Phone: (Ust) 7^ ^ ^^/J state of Califomia Contractor's License Number._ _ Expiration Date. _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • / will provide a final reooft I letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature B-45 Page 1 of 1 Rev 08/11 rBI2 •Z-7r) PPOICCI NUMBER CARLSBAD FIRE DEPARTMENT EXPEDITED PLAN CHECK REQUEST 1, / " ' V •wuwunit^ y-T- /v^ requesting 'Expedited Plan Check Services' and understand I will be levied an additional fee assessed at the rate of $90.00 dollars per hour plus $25.00 dollars administration fee. I tjnderstand that my plans shall not be released until all fees are paid. I, ^the applicant, am solely responsible for all fees due should the project be withdrawn or otherwise not completed. And by signing below I acknowledge that my plans shall be forwarded by the City of Carlsbad to an independent contractor/consultant. \, acknowledge that the 'first review' time for ail expedited Fire plan reviews will be ten- (10) business days from date of submittal. These additional day account for acceptance and delivery of your plans and then the parcel return to our office if recommended for approval. I, the applicant, acknowledges that corrected or revised plans shall be sent directiv to the plan checker, at the address specified on the Correction List, at my cost, parcel post or other means. . acknowledge that a turn-around time for re-submittals is I Your Name five- (5) business days from the date plans are received at the address specified by the plan checker on the Correction List. Once all corrections are made, your plans are then returned to the Carlsbad Fire Department with a "Recommendation for Approver based solely on the adopted Codes and Standards. This is not an approval. Your plans are then forwarded to the Carlsbad Fire Department, and once your plans are received by our office they are subject to an additional review to ensure conformance with Carlsbad Municipal Code. This additional review is subject to an additional review period of seven- (7) 'Government Business' days from date that we receive the plans from the plan reviewer. The Carlsbad Fire Department does not perform 'Over-the-counter' o\an review services. Plans submitted to the Carlsbad Fire Department for review by CFD staff shall be checked on a 'first come, first served' basis and could take 10 days or more for 'First' review. PLEASE GIRCLEiYOyi^ SECEai(3N Applicant Signature, NO Date Copy to Building and Fire Prevention file Revised 10/15/2012 CB122751 2007 COSTA DEL MAR RD LA COSTA 2582 SF REMODEL OF TENNIS SHOP TO INCLUDE EXERCISE AREA \z\z^h^-' TO f(^^ f^ir^e &67-6- i^/ca fcs - Oa^sM^ l\^\\^ CUX^i^^^ i^^i |\3- Oi^ ircS QiA/^ TL \t> (S^U • cv Final Imp. Approved Date BUILDING PLANNING ENGINEERING FIRE Expedite?^) N AFS Checked by /3 By (Lev HazMat APCD Health Forms/Fees Sent Enema Fire HazHealthAPCD PE&M Sewer Stormwater Special Inspection CFD- Y LandUse Rec'd Due? By V N Density ImpArea FY Annex Factor PFF- Y 21 Comments Date Date Date Date Building Planning Engineenng Fire \ 7 l3 A 15 i5 Need? • Done Done SW • Done • Done • Done • Issued