Loading...
HomeMy WebLinkAbout2014 CALETA CT; ; CB143280; Permit11-24-2014 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Cogeneration Permit Permit No:CBl43280 Building Inspection Request Line (760) 602-2725 2014 CALETA CT CBAD COGEN Sub Type: EVG 2151106200 Lot#: 0 $0.00 Constuction Type: NEW Reference #: FREEDMAN RES- ELECT VEHICLE CHARGER IN GARAGE-ON WALL - NO METER Status: ISSUED Applied: 11/24/2014 Entered By: RMA Plan Approved: 11/24/2014 Issued: 11/24/2014 Inspect Area: Plan Check #: Applicant: AMPED ELECTRIC AND DEVELOPMENT STE 133 8280 CLAIRMONT MESA BL SAN DIEGO CA 92111 858-480-1490 Owner: FREEDMAN SHERIL D RESIDENCE TRUST 06-17-96 ET AL C/0 DANA M WALDEN 226 23RD ST SANTA MONICA CA 90402 Building Permit $0.00 PLUMBING TOTAL $0.00 Add1 Building Permit Fee $0.00 ELECTRICAL TOTAL $158.00 Plan Check $0.00 MECHANICAL TOTAL $0.00 Add'l Plan Check Fee $0.00 Additional Fees $0.00 Plan Check Discount Strong Motion Fee Green BIdg Stands (SB1473) Fee $0.00 $1.00 $1.00 TOTAL PERMIT FEES $160.00 Total Fees: $160.00 Total Payments To Date: $160.00 Balance Due: $0.00 Inspector: FINAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen-ed to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required infomiation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3,32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv othenvise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: • PLANNING • ENGINEERING • BUILDING DFIRE nHEALTH • HAZMAT/APCD P.«.Ch...N..(^)/^7j^/) ^ CITY OF CARLSBAD Building Pemiit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 780-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.cari8baclca.gov Est. Value 1 Plan Ck. Deposit y^^Pate/(^3c/ /((^ SWPPP JOB ADDRESS 2014CaletaCt PHASE* |#OFUNrrS I#BEDROOMS SUrTE*/SPACE*/UNIT« CT/PROJECT # FBATHROOMS TENANT BUSINESS NAME ' CONSTR. TVPE OCC. GROUP DESCRIPTION OF WORK: /Delude Squara Feet of Affact«dAraa(<) Install a NEMA14-50 receptacle in the garage for electric vehicle charging EXISTINQ USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS yEsr> YESj |NO| 1 vEsnNoQ APPUCANT NAME Pitnanr Contact Dylan Williams PROPERTY OWNER NAME Robert Freedman ADDRESS 8280 Clairemont Mesa Blvd Suite 133 ADDRESS 2014 Caleta Ct CiTY San Diego STATE CA ZIP 92111 CITY Carlsbad STATE ZIP CA 92009 PHONE 858-480-1490 FAX PHONE FAX EMAIL Dylan@Amped-Electric.com EMAIL freedmanr@aol.com DESIGN PROFESSIONAL CONTKACTOR BUS. NAME Amped Electric ADDRESS ADDRESS 8280 Clairemont Mesa Blvd. Suite 133 CITY STATE ZIP CITY STATE San Diego ZIP CA 92111 PHONE FAX PHONE 858-480-1490 FAX EMAIL EMAIL Dylan@Amped-Electric.com STATE UC.# STATE UC.# 959956 CLASS 1 CITY BUS. LIC.# C-10 1 1238640 civil penalty of not more than five hundred dollars {$500)). WORKERS' COMPENSATION Its Issuance, also requires the 'Section 7000 of Division 3 of the permit subjects the applicant to a Wofkari' Compensation Declaration: / hereby afttm under penalty of perjury one dthe folkmng dedarations: S I hava and will maintain a cartiflcate of consent to self-lnsun for workers' compensation as provided by Section 3700 of the Labor Code, for ttie peffomnance of the wor1< for which lliis pemiK is issued. I have and wHI maintain woiliars' compensrilon, as required by Section 3700 of the Labor Code, for tbe perfonnance of the wori( for which this pennit Is issued. My workers' compensation insurance carrier and poltey number are: Insurance Co.^ Wesco insurance Company Policy No.. WWC3101144 Expiralion Date. 7(28/2015 Bsectkin need not be completed if the permit is for one hundred dollars ($100) or less. Certificata of Exemption: I certify that in the perfomnance of the work for whnh this pennit is issued, I shall not emptoy any peison in any manner so as to become subject to the Woikeis' Compensatkin Laws of California. WARNING: Failure to secure woriters' coinpensation coverage is unlawfuL and shail subject an employer to criminal penalties and chiil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for In Section 370$ of the Lal>or code, intatest and attorney's fees. >eS'cOHTRACTOR SIGNATURE riAGENT DATE 11/17/2014 • AGENT OWNE R - BUiLOER DECLARATION I hereby affirm that I am exempt from Contractor's License Law for the following reason: [~~| I, as owner of the property or my empk)yees with wages as their sole compensation, wiil do the work and the structure is not intended or offered Ibr sale (Sec. 7044, Business and Professions C:ode: The extractor's Lkense law does not apply to an owner of pmperty who buikls or improves thereon, and who does such work himself or thmugh his own emptoyees, provkled that such improvements are not intended or offered tbr sale. If, however, the building or improvement is sold within one year of completkjn, the owner-bulkier will have the burden of proving that he dkl not buikl or improve for the purpose of sale). I I I, as owner of Ihe property, am exclusively ootitracling nilh licensed contractors to constract the project (Sec. 7044, Business and Professtons Code: The Contractor's Ucense Law does nol apply to an owner of property who buikls or Improves theieon, and contracts for such projects with contractor(s) lk»nsed pursuant to the Contractor's Ucense Law). I I I am exempt under Sectton _ .Business and Professtons Clode for this reason: 1.1 personally plan to provide the major iabor and materials for constnicUon of the proposed property improvement •Yes O") 2.1 (have / have not) signed an applKatton tor a buikling pennit for the proposed work. 3.1 have contracted with the foltowing person (finn) to provkle the proposed construction (Inckide name address / phone / contractors' itoense number): 4.1 plan to pmvkle portions of the work, but I have hired the following person to coonlinate, supenise and provkle the major worit (include name / address / phone / contractots' Icense number): 6.1 vnll provkle some of the worit, but I have contracted (hired) the foltowing persons to provkle the worit indkated (include name / address / phone / type of worit): ^eTpROPERTY OWNER SIGNATURE •AGENT DATE COMPLETE THIS SECTION FOR N O N - R E S I D E N T I A L BUILDING PERMITS ONLY Is the applicant or future buikling occupant required to submit a business plan, acutely hazardous materials rag'istratnn fonn or risk management and prevention program under Secttons 255(K, 25533 or 25534 of t Presley-Tanner IHazantous Substance Account Act? • Yes • No Is the appltoant or future buikling occupant required to obtain a pennit from the air pollulton control district or air quality management district? • Yes • Ito lst)iefaiilllytobsconstructedwithin1,0QQ<eetaftheauterboundaiyofaschoQlstts? OYes DNo IF ANY OF THE ANSWERS ARE YES, A FMAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS HET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I heraby affinn that there Is a construction lending agency for the perfonnance of the work this pennit is Issued (Sec. 3097 (i) Civil Code). Lendei'sName Lender's Address APPLICANT CERTIFICATION ioeftiiyihatlhave lead the application and (late lhat the abM inlbmiation Is oonectMid that the Inin I hereby autwrize represenlallffi of the C% of Carisl)ad b enter upon the abov^ AGAINST AaLIABin'IES,JIJIX3»»nS, COSTS AND EXPENSES WHICH liWYIN OSHA: An OSHA pemtf is required tbr excswadons over S'O'deep and denicWon or cons^ EXPiRATX)N: Eveiy pemiit isaied by tie Building Official under Ihe prcM^^ 180 days <i«fn Ihe (tale of such penmltalf8ie buiding wworttaulwiized by VCTAPPUCANT'S SIGNATURE DATE 11/17/2014 ^ PLUMBING, Development Services ELECTRICAL, Building Division c.TY OF MECHANICAL '''''TeXTJ ADI CD A Pi WORKSHEET www.carlsbadca.gov V-./AlxLOD/AL^' B-18 Bulldine@carlsbaclca.gov F>roject Address: 2014 Caleta Ct Permit No.: Information provided below refers to worfe being done on the abov;e mentioned permit only. This form must be competed and returned to the BuildinB Divisiow before the permit con !>• issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains... . New building sewer line? .. . .— Ves No. Number of new roof drains? _ Install/alter water line? _ Number of new wcri:er heaters?....... . .. _ Number of new, relocated or replaced gas outlets? „. _ Number of new hose bibs?............ . .— Residential Permits: New/expanded service: Number of new amps: Minor Remodel Ves No Cominercicd/lndHttilah Tenant Improvement: Number of existing amps Involved in tha project: Number of new amps Itivohedln thh project- New Construction: Amps per Panel: Single Phase . . .......— Number of new amperes_ Three Phase Number of new amperes_ Three Phase 480 . . . Number of new amperes_ Number of new furnaces, A/C, or heat pumps? . New or relocated duct worit? Ves No. Number of new fireplaces? —.. . Number of new exhaust fans?. ..—..... . Relocate/install vent?.. . .—................ ........... . .— Number of new exhaust hoods? .......—. ... .... ............. Number of new boilers or compressors?. . Number of HP B-18 Page 1 of 1 Rev. 03/09 Inspection List Permit*: CB143280 Date Inspection Item 04/21/2015 34 Rough Electric 04/21/2015 34 Rough Electric 04/21/2015 39 Final Electrical 04/21/2015 39 Final Electrical Type: COGEN EVG FREEDMAN RES- ELECT VEHICLE CHARGER IN GARAGE-ON WALL - NO ME Inspector Act Comments Rl AM PLEASE/ ELECTRIC CAR CHARGER PD AP Rl AM PLEASE/ ELECTRIC CAR CHARGER PD AP Wednesday, April 22, 2015 Page 1 of 1 Amped Electric Electrical Contractors License #959956 858.480.1490 www.Aniped-Electric.com Dylan9Anipecl-Eiectrk.com Floor Plan for 2014 Caleta Ct. Carlsbad, CA 92009 Prepared 11/23/2014 22' - 8" 7'-4" 2"-6" l'-4" .<''y Garage Door 16"-0" 18' - 9" r-l" Proposed EV Charger location Garage Door 3"-8" 14' - 6" 2'- 0" 9'-0" l'-2" Amped Electric Reliabllify, IntepHty md dear eommunlcatlon c3^H3aia> ^5 Amped Electric Electrical Contractors License #«I905« 858.480.I490 wwwJVmped-Electric.com Dylan*?Amped-EIectrlc.com Load Calculation for 2014 Caleta Ct. Carlsbad, CA 92009 Prepared 11/20/2014 General loads For Sin sie Famiiy Residentiai Calculated under 220.82B NEC 2008 Description Base Value l\Muitiplier Extended Value Code Reference General Lighting and Receptacles 3Watts/SF 2719 8157 220.82B1 Small Appliance and Laundry Circuits 1500 Watts Each 3 4500 220.82B2 Tliernnador Cooktop Per Nameplate Rating 40 9600 220.82B3B Electric Oven Per Nameplate Rating 33.33333333 8000 220.82B3B Refrigerator Per Nameplate Rating 4.9 1176 220.82B3B Dishwasher Per Nameplate Rating 9.8 1176 220.82B3A Microwave Per Nameplate Rating 12.5 1500 220.82B3A Disposer Per Nameplate Rating 8.2 984 220.82B3A Electric Clothes Dryer Per Nameplate Rating 0 220.82B3C Forced Air Unit Per Nameplate Rating 18 2160 220.82B4 Electric Water Heater Per Nameplate Rating 0 220.82B3D Instant Hot Per Nameplate Rating 0 220.82B3D Pool Motor Per Nameplate Rating 0 220.82B4 Spa Motor and Heater Per Nameplate Rating 0 220.82B4 Permanently Installed Appliance 1 Per Nameplate Rating 220.82B3 Permanently Installed Appliance 2 Per Nameplate Rating 220.82B3 Permanently Installed Appliance 3 Per Nameplate Rating 220.82B3 Permanently Installed Appliance 4 Per Nameplate Rating 220.82B3 General Load Subtotal 37253 First lOKW @ iO0% 10000 Remainder @ 40% 10901.2 Generai Load Total 20901.2 Amped Electric RallabUity, Integrity and daat communictiUon Amped Electric Electrkai Contractors License #959956 U8.480.M90 www.Amped-Electric.com Dylan9Aniped-Electric.com Heating, Cooling and EV Ciiarging loads For Single Famiiy Residential Calculated under 220.82C NEC 2008 Description Base Multiplier Extended Code Value Value Reference Nameplate Ratings of AC Equipment 45 100% 10800 220.82C1 Nameplate Ratings of Heat Pump NO Supplemental Heat 100% 0 220.82C2 Heat Pump NPR With Supplemental Electric Heating 100% of Heat Pump 0 220.82C3 Supplemental Electric Heating for Heat Pump 65% of Supplemental 0 220.82C3 Less Than Four Electric Space Heaters 65% 0 220.82C4 Greater Than Three Electric Space Heaters 40% 0 220.82C5 Electric Vehicle Charger 40 100% 9600 625.41 Heating and Cooling Loads Total 20400 Combined Load Calculation and Expected System Demand General Load Total in Watts 20901.2 Heating, Cooling & EV Load Total in Watts 20400 Combined Total in Watts 41301.2 Total Service Amperage Necessary 172.0883333 Amped Electric /t»ffabiffty. Integrity anddtar eemmunleation MOBILE CONNECTOR - NEMA 14-50 INSTALLATION GUiDE To take full advantage of your Tesia Mobile Connector, work with an electrician to install a NEMA 14-50 outlet where you plan to park your Model S. To ensure uninterrupted charging at full power, the circuit breaker should be rated for 50 amps. You'll find that charging your car is a lot like plugging in your cell phone. For the best experience, we recommend plugging in each evening, or when convenient. DETAILS • Voltage: Single phase, 208-250 volt AC supply, 60 hertz • Current: 50 amp circuit breaker / 40 amp continuous draw • Code: Circuit installation should meet National Electric Code (NEC) wire and breaker ratings. In general, this means 6 AWG wire for installations under 100 feet • Ground Fault Circuit interrupter (GFCI): Not required • Service disconnect: Not required • Outlet: Install within 15 feet of driver side taillight (vehicle is over 16 feet long) and minimum 18 inches above the ground HSs^KA 14-5Q, Ground on Top Image io scale (-2.25" diameter) RECOMMENDED OUTLET LOCATIONS One or two vehicle garage Three vehicle garage f i -r 4 Need help sourcing an electrician, or have questions about home charging insteiilation? Email Testa al: Charginglnsiallaiion^iesiamotors.com or 1-877-798-3752