HomeMy WebLinkAbout2014 CALETA CT; ; CB143280; Permit11-24-2014
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Cogeneration Permit Permit No:CBl43280
Building Inspection Request Line (760) 602-2725
2014 CALETA CT CBAD
COGEN Sub Type: EVG
2151106200 Lot#: 0
$0.00 Constuction Type: NEW
Reference #:
FREEDMAN RES- ELECT VEHICLE
CHARGER IN GARAGE-ON WALL - NO METER
Status: ISSUED
Applied: 11/24/2014
Entered By: RMA
Plan Approved: 11/24/2014
Issued: 11/24/2014
Inspect Area:
Plan Check #:
Applicant:
AMPED ELECTRIC AND DEVELOPMENT
STE 133
8280 CLAIRMONT MESA BL
SAN DIEGO CA 92111
858-480-1490
Owner:
FREEDMAN SHERIL D RESIDENCE TRUST 06-17-96 ET AL
C/0 DANA M WALDEN
226 23RD ST
SANTA MONICA CA 90402
Building Permit $0.00 PLUMBING TOTAL $0.00
Add1 Building Permit Fee $0.00 ELECTRICAL TOTAL $158.00
Plan Check $0.00 MECHANICAL TOTAL $0.00
Add'l Plan Check Fee $0.00 Additional Fees $0.00
Plan Check Discount
Strong Motion Fee
Green BIdg Stands (SB1473) Fee
$0.00
$1.00
$1.00
TOTAL PERMIT FEES $160.00
Total Fees: $160.00 Total Payments To Date: $160.00 Balance Due: $0.00
Inspector:
FINAL
Date: Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
refen-ed to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required infomiation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3,32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv othenvise expired.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: • PLANNING • ENGINEERING • BUILDING DFIRE nHEALTH • HAZMAT/APCD
P.«.Ch...N..(^)/^7j^/)
^ CITY OF
CARLSBAD
Building Pemiit Appiication
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 780-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.cari8baclca.gov
Est. Value
1 Plan Ck. Deposit
y^^Pate/(^3c/ /((^ SWPPP
JOB ADDRESS 2014CaletaCt
PHASE* |#OFUNrrS I#BEDROOMS
SUrTE*/SPACE*/UNIT«
CT/PROJECT # FBATHROOMS TENANT BUSINESS NAME ' CONSTR. TVPE OCC. GROUP
DESCRIPTION OF WORK: /Delude Squara Feet of Affact«dAraa(<)
Install a NEMA14-50 receptacle in the garage for electric vehicle charging
EXISTINQ USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
yEsr> YESj |NO| 1 vEsnNoQ
APPUCANT NAME
Pitnanr Contact Dylan Williams PROPERTY OWNER NAME Robert Freedman
ADDRESS 8280 Clairemont Mesa Blvd Suite 133 ADDRESS
2014 Caleta Ct
CiTY
San Diego
STATE
CA
ZIP
92111
CITY
Carlsbad
STATE ZIP
CA 92009
PHONE
858-480-1490
FAX PHONE FAX
EMAIL
Dylan@Amped-Electric.com
EMAIL
freedmanr@aol.com
DESIGN PROFESSIONAL CONTKACTOR BUS. NAME Amped Electric
ADDRESS ADDRESS
8280 Clairemont Mesa Blvd. Suite 133
CITY STATE ZIP CITY STATE
San Diego
ZIP
CA 92111
PHONE FAX PHONE
858-480-1490
FAX
EMAIL EMAIL
Dylan@Amped-Electric.com
STATE UC.# STATE UC.#
959956
CLASS 1 CITY BUS. LIC.#
C-10 1 1238640
civil penalty of not more than five hundred dollars {$500)).
WORKERS' COMPENSATION
Its Issuance, also requires the 'Section 7000 of Division 3 of the permit subjects the applicant to a
Wofkari' Compensation Declaration: / hereby afttm under penalty of perjury one dthe folkmng dedarations:
S I hava and will maintain a cartiflcate of consent to self-lnsun for workers' compensation as provided by Section 3700 of the Labor Code, for ttie peffomnance of the wor1< for which lliis pemiK is issued.
I have and wHI maintain woiliars' compensrilon, as required by Section 3700 of the Labor Code, for tbe perfonnance of the wori( for which this pennit Is issued. My workers' compensation insurance carrier and poltey
number are: Insurance Co.^ Wesco insurance Company Policy No.. WWC3101144 Expiralion Date. 7(28/2015
Bsectkin need not be completed if the permit is for one hundred dollars ($100) or less.
Certificata of Exemption: I certify that in the perfomnance of the work for whnh this pennit is issued, I shall not emptoy any peison in any manner so as to become subject to the Woikeis' Compensatkin Laws of
California. WARNING: Failure to secure woriters' coinpensation coverage is unlawfuL and shail subject an employer to criminal penalties and chiil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for In Section 370$ of the Lal>or code, intatest and attorney's fees.
>eS'cOHTRACTOR SIGNATURE riAGENT DATE 11/17/2014 • AGENT
OWNE R - BUiLOER DECLARATION
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
[~~| I, as owner of the property or my empk)yees with wages as their sole compensation, wiil do the work and the structure is not intended or offered Ibr sale (Sec. 7044, Business and Professions C:ode: The extractor's
Lkense law does not apply to an owner of pmperty who buikls or improves thereon, and who does such work himself or thmugh his own emptoyees, provkled that such improvements are not intended or offered tbr
sale. If, however, the building or improvement is sold within one year of completkjn, the owner-bulkier will have the burden of proving that he dkl not buikl or improve for the purpose of sale).
I I I, as owner of Ihe property, am exclusively ootitracling nilh licensed contractors to constract the project (Sec. 7044, Business and Professtons Code: The Contractor's Ucense Law does nol apply to an owner of
property who buikls or Improves theieon, and contracts for such projects with contractor(s) lk»nsed pursuant to the Contractor's Ucense Law).
I I I am exempt under Sectton _ .Business and Professtons Clode for this reason:
1.1 personally plan to provide the major iabor and materials for constnicUon of the proposed property improvement •Yes O")
2.1 (have / have not) signed an applKatton tor a buikling pennit for the proposed work.
3.1 have contracted with the foltowing person (finn) to provkle the proposed construction (Inckide name address / phone / contractors' itoense number):
4.1 plan to pmvkle portions of the work, but I have hired the following person to coonlinate, supenise and provkle the major worit (include name / address / phone / contractots' Icense number):
6.1 vnll provkle some of the worit, but I have contracted (hired) the foltowing persons to provkle the worit indkated (include name / address / phone / type of worit):
^eTpROPERTY OWNER SIGNATURE •AGENT DATE
COMPLETE THIS SECTION FOR N O N - R E S I D E N T I A L BUILDING PERMITS ONLY
Is the applicant or future buikling occupant required to submit a business plan, acutely hazardous materials rag'istratnn fonn or risk management and prevention program under Secttons 255(K, 25533 or 25534 of t
Presley-Tanner IHazantous Substance Account Act? • Yes • No
Is the appltoant or future buikling occupant required to obtain a pennit from the air pollulton control district or air quality management district? • Yes • Ito
lst)iefaiilllytobsconstructedwithin1,0QQ<eetaftheauterboundaiyofaschoQlstts? OYes DNo
IF ANY OF THE ANSWERS ARE YES, A FMAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS HET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I heraby affinn that there Is a construction lending agency for the perfonnance of the work this pennit is Issued (Sec. 3097 (i) Civil Code).
Lendei'sName Lender's Address
APPLICANT CERTIFICATION
ioeftiiyihatlhave lead the application and (late lhat the abM inlbmiation Is oonectMid that the Inin
I hereby autwrize represenlallffi of the C% of Carisl)ad b enter upon the abov^
AGAINST AaLIABin'IES,JIJIX3»»nS, COSTS AND EXPENSES WHICH liWYIN
OSHA: An OSHA pemtf is required tbr excswadons over S'O'deep and denicWon or cons^
EXPiRATX)N: Eveiy pemiit isaied by tie Building Official under Ihe prcM^^
180 days <i«fn Ihe (tale of such penmltalf8ie buiding wworttaulwiized by
VCTAPPUCANT'S SIGNATURE DATE 11/17/2014
^ PLUMBING, Development Services
ELECTRICAL, Building Division
c.TY OF MECHANICAL '''''TeXTJ
ADI CD A Pi WORKSHEET www.carlsbadca.gov
V-./AlxLOD/AL^' B-18 Bulldine@carlsbaclca.gov
F>roject Address: 2014 Caleta Ct Permit No.:
Information provided below refers to worfe being done on the abov;e mentioned permit only.
This form must be competed and returned to the BuildinB Divisiow before the permit con !>• issued.
Building Dept. Fax: (760) 602-8558
Number of new or relocated fixtures, traps, or floor drains... .
New building sewer line? .. . .— Ves No.
Number of new roof drains? _
Install/alter water line? _
Number of new wcri:er heaters?....... . .. _
Number of new, relocated or replaced gas outlets? „. _
Number of new hose bibs?............ . .—
Residential Permits:
New/expanded service: Number of new amps:
Minor Remodel Ves No
Cominercicd/lndHttilah
Tenant Improvement: Number of existing amps Involved in tha project:
Number of new amps Itivohedln thh project-
New Construction: Amps per Panel:
Single Phase . . .......— Number of new amperes_
Three Phase Number of new amperes_
Three Phase 480 . . . Number of new amperes_
Number of new furnaces, A/C, or heat pumps? .
New or relocated duct worit? Ves No.
Number of new fireplaces? —.. .
Number of new exhaust fans?. ..—..... .
Relocate/install vent?.. . .—................ ........... . .—
Number of new exhaust hoods? .......—. ... .... .............
Number of new boilers or compressors?. . Number of HP
B-18 Page 1 of 1 Rev. 03/09
Inspection List
Permit*: CB143280
Date Inspection Item
04/21/2015 34 Rough Electric
04/21/2015 34 Rough Electric
04/21/2015 39 Final Electrical
04/21/2015 39 Final Electrical
Type: COGEN EVG FREEDMAN RES- ELECT VEHICLE
CHARGER IN GARAGE-ON WALL - NO ME
Inspector Act Comments
Rl AM PLEASE/ ELECTRIC CAR CHARGER
PD AP
Rl AM PLEASE/ ELECTRIC CAR CHARGER
PD AP
Wednesday, April 22, 2015 Page 1 of 1
Amped Electric
Electrical Contractors
License #959956
858.480.1490
www.Aniped-Electric.com
Dylan9Anipecl-Eiectrk.com
Floor Plan for 2014 Caleta Ct. Carlsbad, CA 92009
Prepared 11/23/2014
22' - 8"
7'-4" 2"-6"
l'-4"
.<''y
Garage Door
16"-0"
18' - 9"
r-l"
Proposed
EV Charger
location
Garage Door
3"-8"
14' - 6"
2'- 0"
9'-0" l'-2"
Amped Electric
Reliabllify, IntepHty md dear eommunlcatlon
c3^H3aia>
^5 Amped Electric
Electrical Contractors
License #«I905«
858.480.I490
wwwJVmped-Electric.com
Dylan*?Amped-EIectrlc.com
Load Calculation for 2014 Caleta Ct. Carlsbad, CA 92009
Prepared 11/20/2014
General loads For Sin sie Famiiy Residentiai Calculated under 220.82B NEC 2008
Description Base Value l\Muitiplier Extended Value Code Reference
General Lighting and Receptacles 3Watts/SF 2719 8157 220.82B1
Small Appliance and Laundry Circuits 1500 Watts Each 3 4500 220.82B2
Tliernnador Cooktop Per Nameplate Rating 40 9600 220.82B3B
Electric Oven Per Nameplate Rating 33.33333333 8000 220.82B3B
Refrigerator Per Nameplate Rating 4.9 1176 220.82B3B
Dishwasher Per Nameplate Rating 9.8 1176 220.82B3A
Microwave Per Nameplate Rating 12.5 1500 220.82B3A
Disposer Per Nameplate Rating 8.2 984 220.82B3A
Electric Clothes Dryer Per Nameplate Rating 0 220.82B3C
Forced Air Unit Per Nameplate Rating 18 2160 220.82B4
Electric Water Heater Per Nameplate Rating 0 220.82B3D
Instant Hot Per Nameplate Rating 0 220.82B3D
Pool Motor Per Nameplate Rating 0 220.82B4
Spa Motor and Heater Per Nameplate Rating 0 220.82B4
Permanently Installed Appliance 1 Per Nameplate Rating 220.82B3
Permanently Installed Appliance 2 Per Nameplate Rating 220.82B3
Permanently Installed Appliance 3 Per Nameplate Rating 220.82B3
Permanently Installed Appliance 4 Per Nameplate Rating 220.82B3
General Load Subtotal 37253
First lOKW @ iO0% 10000
Remainder @ 40% 10901.2
Generai Load Total 20901.2
Amped Electric
RallabUity, Integrity and daat communictiUon
Amped Electric
Electrkai Contractors
License #959956
U8.480.M90
www.Amped-Electric.com
Dylan9Aniped-Electric.com
Heating, Cooling and EV Ciiarging loads For Single Famiiy Residential Calculated under 220.82C NEC 2008
Description Base Multiplier Extended Code
Value Value Reference
Nameplate Ratings of AC Equipment 45 100% 10800 220.82C1
Nameplate Ratings of Heat Pump NO Supplemental Heat 100% 0 220.82C2
Heat Pump NPR With Supplemental Electric Heating 100% of Heat Pump 0 220.82C3
Supplemental Electric Heating for Heat Pump 65% of Supplemental 0 220.82C3
Less Than Four Electric Space Heaters 65% 0 220.82C4
Greater Than Three Electric Space Heaters 40% 0 220.82C5
Electric Vehicle Charger 40 100% 9600 625.41
Heating and Cooling Loads Total 20400
Combined Load Calculation and Expected System Demand
General Load Total in Watts 20901.2
Heating, Cooling & EV Load Total in Watts 20400
Combined Total in Watts 41301.2
Total Service Amperage Necessary 172.0883333
Amped Electric
/t»ffabiffty. Integrity anddtar eemmunleation
MOBILE CONNECTOR - NEMA 14-50
INSTALLATION GUiDE
To take full advantage of your Tesia Mobile Connector, work with
an electrician to install a NEMA 14-50 outlet where you plan to park
your Model S.
To ensure uninterrupted charging at full power, the circuit breaker
should be rated for 50 amps.
You'll find that charging your car is a lot like plugging in your cell
phone. For the best experience, we recommend plugging in each
evening, or when convenient.
DETAILS
• Voltage: Single phase, 208-250 volt AC supply, 60 hertz
• Current: 50 amp circuit breaker / 40 amp continuous draw
• Code: Circuit installation should meet National Electric Code
(NEC) wire and breaker ratings. In general, this means 6 AWG
wire for installations under 100 feet
• Ground Fault Circuit interrupter (GFCI): Not required
• Service disconnect: Not required
• Outlet: Install within 15 feet of driver side taillight (vehicle is
over 16 feet long) and minimum 18 inches above the ground HSs^KA 14-5Q, Ground on Top
Image io scale (-2.25" diameter)
RECOMMENDED OUTLET LOCATIONS
One or two vehicle garage Three vehicle garage
f i
-r 4
Need help sourcing an electrician, or have questions about home charging insteiilation?
Email Testa al: Charginglnsiallaiion^iesiamotors.com or 1-877-798-3752