HomeMy WebLinkAbout2026 CALETA CT; ; CB153102; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plumbing/Mechanical/Electrical (PME) Permit
09-21-2015 Permit No: CB153102
Buildin~) Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC#:
Project Title:
Applicant:
2026 CALETA CT CEiAD
PME
2151106300 Lot#: 0
WHITFIELD: UPGRADE PANEL TO
200A
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
09/21/2015
JMA
09/2112015
09/21/2015
VOLT ELECTRIC, INC. WHITFIELD RODNEY A&KATHERINE E
753 OSBORNE ST
VISTA CA 92084-1805
760-822-9743
Plumbing Fees
Electrical Fees
Mechanical Fees
Other PME Fees
TOTAL PERMIT FEES
P 0 BOX 2525
OAKHURST CA 93644
$0.00
$163.00
$0.00
$0.00
$163.00
Total Fees: $163.00 Total Payments To Date: $163.00 Balance Due:
Inspector:
FINAL~VAL
Date: ~ Clearance:
$0.00
NOllCE: Please take NOllCE that approval ci your project indudes tre "lrrpa;ition'' d fees, dedicatims, reservatioos, or ott-er exa::tioos hereafter oollectively
referred to as "feeslexa::tions." You have 00 days from the date this pernit was issued to protest ifllX)Sition d these feeslexa::tioos. If you protest them, you rrust
fdiOJV tre protest proo'ldures set forth in C?overrment Code Section OOJ20(a), and file tre protest and any ott-er required inforrration wth tre Oty rv'enager for
[JI"OO"lSSing in aa:orclanre wth Carlsbad fvl.Jnidpal Code Section 3.32.030. Failure to tirrely fdiOJVthat procedure -Mil bar any subsequent l~jal aotion to attack,
re.iieN, set aside, vdd, or annul their irrpa;ition.
You are rerroy F\..Rll-iER I\OllRED that your right to protest tre spedfied feeslexa::tims IXES NOT APPLY to Wcll:er and sewer aJilnedic:n fees and capacity
changes, nor planning, zoning, grading or ott-er sirrilar application [JI"OO"lSSing or service fees in aJilnedion wth this project. NOR IXES IT 1'\PPL Y to any
feeslexaotims d W1ich vou have oreviouslv been given a NOllCE sirrilar to tns. or as to IJ\hch tre statute of lirritatioos has previously otherwise exdred.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: OPLANNING 0ENGINEERING 0BUILOING OFIRE OHEALTH OHAZMATIAPCD
Building Permit Application Plan Check No. CBfs. ?lOZ. City of '1635 Faraday Ave., Carlsbad, CA 92008 Est. Value
Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov
www.carlsbadca.gov Date q, "2..-1-( ( lswPPP
JOB ADDRESS 'ZOZG, SUITE#/SPACE#/UNIT# _lAPN (~LC:.."l~ CT -- -
CT/PROJECT # 'I LOT# I PHASE#
1
#OF UNITS r BEDROOMS #BATHROOMS I TENANT BUSINESS NAME rONSTR. TYPE
1
occ. GROUP
3 OSOctx? '/7§(;)
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
0fG-~~.t:£' J-.1 -A-1 jl.) £Lt. C\{C_l efrL PAN£l...-10 200 At-{f Se: (l___\/it/2
~ /JV5'TA-LL uJJD~::~'R.C.flDwN 'D CoJJ~0~~
EXISTING USE I PROPOSED us1: I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE lAIR CONDITIONING rRESPRINKLERS
YESO NoD YESONoD YEsONoO
APPLICANT NAME PROPERTY OWNER NAME
Primary Contact
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE ZIP
PHONE I FAX PHONE I FAX
EMAIL EMAIL
DESIGN PROFESSIONAL CONT~ACT~~ BUSl_!Wl_E • .., .-..-/ \/n, L"J" t= L -t:.<:.."t 5C l t_ J.;..)C.,
ADDRESS ADDRESS /
'7 .c:-~ '~ Ro<Z.JV £ s:r CITY STATE ZIP CITY STATE ZIP
\/tSTJt-CA ct·zcf:)t.j
PHONE I FAX PHONE I FAX 7bt> '52<--97'13
EMAIL EMAIL 1/ot.lcl:Ec:J/2...;(_~ C.cx . .r-JtS·I
I STATE LIC. # STATE UC.# I CLASS ICITYB4~'p 1 ;ed, Cj'5fj2y'~ C-/6
(Sec, 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or re air any structure, prior to its issuance, al!o requires the applicant for such permit to f1le a s1gned statement that he 1s licensed pursuant to the prov1s1ons of the Contractor's License Law {C~apter 9, commendmg w1th Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
Workers' Compensation Declaration: I hereby affinn under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self·insure· for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, My workers' compensation insurance carrier and policy
----------~-----------Policy No. Expiration Date _________ _
need not be completed if the permit is for one hundred dollars ($1 00) or less.
of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
WARNING: Failure to secure workers' compensatior1 coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, d~ ;s pro. vided Section 3706 of the Labor code, interest and attorney's fees.
~CONTRACTOR SIGNATURE 7 VL--
I hereby affinn that I am exempt from Contractor's License Law for thE! following reason:
D
D
D
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered tor sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered tor
sale. It, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement DYes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired thE! following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
~PROPERTY OWNER SIGNATURE ~ 0AGENT DATE
I certify that I have read the application and state that the above infonnation is correct and that the infonnation on the plans is accurate.\ agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned properly for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA penn it is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every pennitissued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such penni! is not commenced within
180 days from the date of such penn it or if the building or work authorized by such penni! is suspended or abandoned at any time after the work is commenced for a period of 180 da,ys (Section 106.4.4 Unifonn Building Code).
APPLICANT'S SIGNATURE DATE
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE:.
Complete the following ONLY if a Certificate of Occupancy will be requested at final iinspection.
OF OCCUPANCY !Commercia! Projects 0 1'1 iy!
Fax (760) 602-8560, Email building@carlsbadGa.gov or Mail the completed form to City of Cartsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE I FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
PICKUP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
ASSOCIATED CB# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION
MAIL/ FAX TO OTHER:
CHANGE OF USE/ NO CONSTRUCTION
_/i:S APPLICANT'S SIGNATURE DATE
Inspection List
Permit#: CB153102 Type: PME
Date Inspection Item l(lspector Act
Rl 04/20/2016 39 F ina I Electrical
04/20/2016 39 Final Electrical
04/12/2016 39 Final Electrical
AEK Fl
04/12/2016 39 Final Electrical AEK
11/03/2015 31 Underground/Conduit-V\Iirin AEK
11/03/2015 33 Service Change/Upgrade AEK
11/03/2015 33 Service Change/Upgrade AEK
Wednesday, April20, 2016
Rl
NR
co
co
AP
WHITFIELD: UPGRADE PANEL TO
200A
Comments
GATE OPEN ON LEFT CARD@ PANEL
NO ONE HOME
WRAP GAS LINE WERE COVERING IS
DAMAGED
WALL FRAMING NEEDS CORRECTED,
CALL FOR INSPECTION
OK TO ENERGIZE, NEEDS FRAMING
CORRECTED
Page 1 of 1
ELECTRIC UNDERGROUND METER & SERVICE LOCATION
Customer Copy
Notification#: 300000047561 Job#: I TB: 1127-F6
Wanted Date: ON INSPECTION Date Prepared: 07/06/2015
Customer Type: Residential(1-2 Units) Service Type: UG SERVICE REWIRE/RELOCATION
Project Title: WHITFIELD, CATHERINE (SOT)
Project Address: 2026 CALETA CT I Project City: CARLSBAD
Additional Address Info:
Customer POC: CATHERINE WHITFIELD Customer Phone #: 760 703 6065
SDGE Contact: Service Coordinator Contact Info: DANNY SADICK,760-476-5614
D Traffic Control Permit Required 0 SDG&E Application Required-Call: 1-800-411-7343
Excavation/Encroachment Permits Requin~d By:
Municipal Inspection required By: CITY OF CARLSBAD J Temp Service Charge due on First Bill $ 0.00
SERVICE ATTACHMENT POINT AND/OR METER LOCATION:
Locate the new 200 amp meter panel on the North wall near the North/West corner. Customer is to provide all excavation, trench, 2"
conduit, backfill, compaction, 3/4" pulling cmd measuring tape in conduit and surface repair from handhole to new mete1· panel. Take
conduit to within distance instructed by SDG&E inspector. See SDG&E Service and Standards Guide pages 605 and 1008 for
specifications. Prior to digging, please contact your Service Coordinator Danny Sadick at 760 476 5614 to schedule a pre-meet with
your trench inspector.
Station 10 #: 755-220 Structure #: SH427388 J Joint Trench With:
Handhole Installed By: Handhole Lid Shall Read: Standards Pag1e:
Ladder Arms: I Stop Trench: from Pole Riser Quad:
Bend Installed By: SDG&E I Bend Type: HANDHOLE Bend Info: 2" SIO DEG 36"R DB60
Conduit Installed By: CUSTOMER Conduit Size: 2"
Service Panel Rating: 200 Number/Size of Main Switch: 1/200 I Voltage: 120/240
#ofWires: 3 Phase: 1 Utilities Maximum Contribution to Fault Current: 10000
Metering: Self-Contained Meter Clips: 4
Meter height --4'0" min. (3'0" min. for multiple installation) --6'3" max. From finish grade to centerline of meter base. Meters are required to
be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition.
Provide 3-ft. x 3-ft. clear and level working1 space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E
office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address
and unit number.
PROCEDURE FOR INSTALLATION
1. PHONE DIG ALERT"811" AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILITIES.
2. Phone Service Coordinator at 760-476-5614 for the following:
- 3 Working days prior to trenching to arrange pre-meet with inspector and initiate trenching process.
-After excavation of trench, installation of conduit and service entrance equipment at meter location, CALL FOH INSPECTION. Do
not cover conduit without inspector's written approval to backfill.
-When trench is backfilled and compacted, CALL FOR INSPECTION.
-If service entrance equipment is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT.
3. Meter cannot be set until inspector has approved installation, including service equipment, and receipt of city/county/state inspection
Additional Information: 0 Right of Way Required Assessor's Parcel Number:
To minimize the electrical outage, you are advised to schedule a morning disconnect with an afternoon reconnect. There is no charge
for this service. Before you change out your meter consider (1) SDG&E needs 15 working days advance notice to schedule a crew and
(2) SDG&E will not reconnect the service without municipal approval on the new panel. Please contact the City/County regarding
permits and inspections.
If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt worl; immediately and it vYill
be your responsibility to remove and or cl1ean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no
liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of
construction unless it is through negligence of SDG&E.
Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements.
Building address and/or houseline must be permanently identified prior to meter set. Information on this sheet is vo•id after six (6) months.
Keep this notice with building permit.
I Planned By: Jennifer Magee jPhone#:7604765609 J