Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2032 CIMA CT; ; CB981500; Permit
BUILDING PERMIT 05/18/98 09 04 Page 1 of 1 Job Address 2032 CIMA CT Suite Permit lype MISCELLANEOUS Parcel No 216-491-04-00 Lot# Permit No CB981500 Pioject No A9802000 Development No Valuation 10,016 Occupancy Group Reference* Description RE-ROOF,3200 SF,STANDARD TILE WITH S1RUCT CALCS Appl/Ownr CAHEY ROOFING 3048 VIA MARIPOSA CARLSBAD CA 92009 **A Fees Required *** Construction Type NEW Status ISSUED Applied 05/18/98 Apr/Issue 05/18/98 Entered By RMA 760 591-3123 Collected & Credits Fees Adjustments Total Fees Fee description Miscellaneous Fee # * MISCELLANEOUS TOT * *, * 00 00 203 00 Ext fee Data .Q5/1B/28. JOfiQl.QL- -Q2__ 203 00 FINAL APPROVAL INSP CLEARANCE, CITY OF CARLSBAD 2075 Las Palmas Dr Carlsbad CA 92009 (619) 438 1161 PERMIT APPLICATION v CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr Carlsbad CA 92009 (760)438 1161 1 PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO Hfl EST VAL Plan Ck Deposit Validated By, Date C"<•—n V Address (include Bldg/Suite »)Business Name (at this address) CT Legal Description t No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel * r^j_o_L Existing Use Proposed Use Description of Work CONTACT PERSON (H different from applicant) SO FT *of Stones t of Bedrooms # of Bathrooms Name 3 APPLICANT Address Contractor D Agent for Contractor City Owner Q Agent for Owner State/Zip Telephone #Fax * Name 4 PROPERTY OWNER Address City State/Zip Telephone * Name *-* Address City State/Zip Telephone * E CONTRACTOR COMPANY NAME " ~" " -"—-" ™~ ~—^"—t___,_^- (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to Its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars I $500!) Ltl CoL kv *> 1-frU C, ^Cfi 3 j t3> Name State License * Address License Class t. City State/Zip City Business License * Telephone * Designer Name Address City State/Zip Telephone State License # 6 WORKERS COMPENSATION ~ ~ Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self Insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued ,0- I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company STLVl*- Rtflfr-. Policy No ^ H Vp- ^ 9? Expiration Pete I ~ ) ~ Cl *f (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100) OR LESS) 0 CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ eny person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage la unlawful and (hall subject an employer to criminal pwiattles end civil fines up to one hundred thousand dollars ($100 000) hi addition to the cost of compensation damages as provided for hi Section 3706 of the Labor code Interest and attorney « fees SIGNATURE "V\J~-> W Cc>->^ DATE JT / fr? *? B 7 OWNER BUILDER DECLARATION ~ — T. < frr 1 hereby affirm that I am exempt from the Contractor s License Law for the following reason Q I as owner of the property or my employees with weges as their sole compensation will do the work and the structure rs not intended or offered for aale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such Improvements are not intended or offered for aale If however the building or Improvement Is sold within one year of completion the owner builder will have the burden of proving that he did not build or Improve for the purpose of aale) 0 I 8S owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(n) licensed pursuant to the Contractor s License Law) Q I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property Improvement Q YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors hceruie number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / addross / phone number / contractors license number) ^ 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work Indicated (Include name / address / phone number / type of work) DATEPROPERTY OWNER SIGNATURE _ COMPLETE TK S SECTION FOR AOAWZCS/DfiVTMi BUILDING PERMITS ONLY" Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 2SS05 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management district? O YES D NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 3 CONSTRUCTION LENDING AGENCY " » — -- w , ^. -,,_., I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER S ADDRESSLENDER S NAME 9 APPLICANT CERTIFICATION ~ ~ ~ " —™ "" ~ f - *•---» , I certify that I have read the application and state that the above information is correct end that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the OtT of Carlsbad to enter upon the above mentioned property for mspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories m height EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building ot work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance City Of Carlsbad SUPPLEMENTAL BUILDING PERMIT APPLICATION FOR REROOFING 1 JOB ADDRESS 2 TYPE OF BUILDING RESIDENTIAL ^ COMMERCIAL 3 ROOF SLOPE RISE £ inches in 12 inches 4 NUMBER OF EXISTING ROOF COVERING (circle one) ©23 5 TYPE OF EXISTING ROOF COVERING Sh^Ve. SHEATHING ^ *6 NEW ROOF MATERIAL ^V v. c. CLASS ^ WEIGHT PER SQUARE 7 NUMBER OF SQUARES_22; _ 8 TRADE NAME Ton l«o so. MANUFACTURER '-i^ 9 ROOF SYSTEM LISTING UL No _ ICBO No 10 IS THE EXISTING STRUCTURAL DESIGN SUFFICIENT TO SUSTAIN THE WEIGHT OF THE PROPOSED ROOF? (YEsJ) NO All roof coverings are required to be CLASS A Combustible roof coverings of any type or classification are prohibited I understand the following inspections are required 1 Tear Off/Pre-mspection prior to install new roof covering 2 Final Inspection I agree to provide a ladder extending at least 2 rungs above the roof for inspection Signature K>— < ^ C — » — _ Date S- ) ^ 9 g Contractor _ Owner _ Contractor Name *6 - Rolled Roofing, Standard/Lite Tile, Asphalt/Comp Fiberglass, Built up, Other CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB981500 FOR 05/22/98 DESCRIPTION RE-ROOF,3200 SF,STANDARD TILE WITH STRUCT CALCS TYPE MISC JOB ADDRESS 2032 CIMA CT APPLICANT CAHEY ROOFING PHONE CONTRACTOR PHONE OWNER PHONE INSPECTOR AREA PLANCK* CB981500 OCC GRP CONSTR TYPE NEW STE LOT 760 591-3123 REMARKS C/CAHEY ROOF/591-3123 SPECIAL INSTRUCT INSPECTOR TOTAL TIME —RELATED PERMITS—PERMIT* TYPE CB880504 PLUM STATUS EXPIRED CD 19 LVL DESCRIPTION ST Final Structural ACT COMMENTS ft.o DATE DESCRIPTION 051998 Roof/Reroof ***** INSPECTION HISTORY ***** ACT INSP COMMENTS AP RB TO INVOICE Myers Engineering 1290 Ridgeview Way Bomta, CA91902 (619)421-4211 S Date 32 cr CA OWNERS PROJECT DESCRIPTION Structural Calculations for a Reroofing Project - Single Family Residence SERVICES RENDERED BY Myers Engineering Burton S Myers RCE # 24928 Total Amount Due $275 00 STRUCTURAL CALCULATIONS FOR A RRROOFING PROJECT I LOCATION \ CA- OWNER. 4 CONTRACTOR. RNGINEF.R. Burton S Myers 1290RidgeviewWay Bomta,CA91902 (619)421-4211 RCE 24928 Exp 12 31 01 The work will consist of removing the existing wood shake roof down to the spaced sheeting Adding plywood sheeting (or equal), additional braces rafters and gusset plates if needed and a new tile roof per the manufacturers recommendations ! I I I I I I 1 I 1 I < I I I I i I I I I 1 1 < MI i ig//0 t ! i I I ! , i 1 '! l : i • t i i i 1 i i i i i < . i i i i . i i I i I M I i I !i ; ; ; i i i i i « . i -';!;! i i I . ; \ I I RAFT/TXLS5 SUDPE, i — — 34- UJ r 43 1 t t t t^t f lit 1 I L I J IS *1 # SP 542^^- 5"14- u5r / Ni GENERAL CONDTTTONS 1 THE SOLE PURPOSE OF THESE STRUCTURAL CALCULATIONS IS TO pr DETERMINE THE GENERAL CONDITIONS OF THE OVER ALL STRUCTURAL ROOF SYSTEM AND TO DETERMINE WHETHER THE ROOF SYSTEM CAN STRUCTURALLY SUPPORT THE INSTALLATION OF THE NEW PROPOSED ROOF MATERIALS 2 THE INSPECTION PORTION OF THE CALCULATIONS WELL CONSIST OF DETERMINING THE SIZE MEMBERS THAT ARE NEEDED TO SUPPORT THE NEW ROOF SYSTEM IN THOSE CASES WHERE THE EXISTING ROOF SYSTLM DOES NOT MEET THE MINIMUM BUILDING CODE REQUIREMENTS RECOMMENDATIONS WILL BE MADE TO ADD ADDITIONAL BRACES SUPPORTS OR OTHER STRUCTURAL MEMBERS TO INCREASE THE VALUES OF THE ROOF SYSTEM \ 3 THE INSPECTION IS GENERAL IN SCOPE AND DOES NOT INVOLVE INSPECTING EACH INDIVIDUAL MEMBER 4 THE INSPECTION DOES NOT INVOLVE LOOKING FOR DAMAGE CAUSED BY TERMITES DRYROT OR OTHER SOURCES 5 DURING THE COURSE OF THIS INSPECTION CERTAIN AREAS OF THE ROOF MAY NOT BE ACCESSIBLE THOSE AREAS SHOULD BE OBSERVED AFTER THE EXISTING ROOF IS REMOVED PRIOR TO INSTALLING THE NE ROOF 6 ROOF SHEETING UNLESS SPECIFIED IN THE CALCULATIONS THE ROOF SHEETING WILL BE A MINIMUM 7/16 CDX PLYWOOD 7/16 OSB (NER-124) OR EQUAL WITH8DS@ 6 O/C EDGES AND 12' O/C FIELD AND BOUNDAPY INSTEAD OF NAILS STAPLES MAY BE USED PER TABLE 23-Q FOOTNOTE #9 1 RAFTER TIES / GARAGE CEILING JOISTS - WHEN RAFTER TIES OR GARAGE CEILING JOISTS ARE USED THEY SHALL BE PLACED ON ALL RAFTERS NOT EVERY OTHER RAFTER MAXIMUM SPACING FOR RAFTER TIES IS 24 O/C 8 PURLINS IF PURLINS ARE USED AS PART OF THE SUPPORT SYSTEM TO REDUCE THE SPAN OF THE ROOF RAFTERS THE FOLLOWING CONDITIONS MUST BE MET A PURLINS MUST BE EQUAL OR LARGER IN SIZE THAN THE RAFTERS THEY SUPPORT B THE MAXIMUM SPAN FOR 2x4 PURLINS SHALL BE 4 FEET C THE MAXIMUM SPAN FOR 2 x 6 OR LARGER PURLINS SHALL BE 6 FEET THE STRUTS WHICH SUPPORT THE PURLINS AND CARRY THE LOADS TO BEARING WALLS SHALL BE A MINIMUM SIZE OF 2x4 AND THE UNBRACED LENGTH SHALL NOT EXCEED 8 FEET 9 THIS HOUSE WAS MEASURED AND INSPECTED UNDER MY DIRECTION TO DETERMINE THE TYPE AND SIZE OF THE STRUCTURAL MEMBERS (COUNTY OF SAN DIEGO) 10 TfflS ENGINEERING REPORT (INSPECTION AND CALCULATIONS) IS PRIMARILY CONCERNED WITH THE ROOF SYSTEM IT HAS TO BE ASSUMED THAT THE VERTICAL STRUCTURAL SUPPORT MEMBERS AND THE FOUNDATION SYSTEM WAS ORIGINALLY DESIGNED AND CONSTRUCTED TO THE BUILDING CODES AND ARE SUFFICIENT TO SUPPORT THE ROOF SYSTEM 11 WHENEVER THE ROOF SYSTEM HAS BEEN DETERMINED BY RAFTER TAILS (REFEREED TO IN THE SECTION DRAWINGS), THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE SIZE AND SPACING OF THESE RAFTERS AFTER THE ROOF IS REMOVED 12 THE CITY OF SAN DIEGO REQUIRES THAT CODE APPROVED SMOKE DETECTORS BE INSTALLED WHEN A REPAIR OR ALTERATION IS MADE TO A RESIDENTIAL UNIT WHICH EXCEED $1 000 00 A CODE APPROVED SMOKE DETECTOR IS REQUIRED TO BE INSTALLED IN EACH SLEEPING ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA (SECTION 1210 UNIFORM BUILDING CODE) SD PO BOX 807 SAN FRANCISCO CA 94101-0807 COMPENSATION I N S U Ft A N CE F-LJND CERTIFICATE OF WORKERS COMPENSATION INSURANCE POLICY NUMBER 446-98 UNIT OOOO244 ISSUE DATE O1-01-98 CERTIFICATE EXPIRES 01-01-99 STATE CONTRACTORS LICENSE BOARD-WORKER'S COHP JOB LIC # 584362 BOX 26000 INCEPTION BATE 01-O1-98 SACRAMENTO CA 95826 DO SAN DIEGO This is to certify that we have issued a valid Workers Compensation insurance policy in a form approved by the California Insurance Commissioner to the employer named below for the policy period indicated This policy is not subject to cancellation by the Fund except upon 10 days advance written notice to the employer We will also give you 10 days advance notice should this policy be cancelled prior to its normal expiration This certificate of insurance is not an insurance policy and does not amend extend or alter the coverage afforded by the policies listed herein Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate of insurance may be issued or may pertain the insurance afforded by the policies described herein is subject to all the terms exclusions and conditions of such policies PRESIDENT EMPLOYER'S LIABILITY LIMIT INCLUDING DEFENSE COSTS $1 OOO OOO OO PER OCCURRENCE STANDARD EXCLUSION INDIVIDUAL EMPLOYERS AND HUSBAND AND WIFE EMPLOYERS ARE NOT ELIGIBLE FOR BENEFITS AS EMPLOYEES UNDER THIS POLICY EMPLOYER LEGAL NAME CAHEY CUSTOM ROOFING CAHEY BRIAN AND 3048 VIA MARIPOSA CAHEY MONICA CARLSBAD CA 92009