Loading...
HomeMy WebLinkAbout2032 CORTE DEL NOGAL; 100; CB032848; Permitt2-12-2003 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB032848 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2032 CORTE DEL NOGAL CBAD St 100 Tl Sub Type Lot# $137,13000 Construction Type Reference # EBD GROUP / SPEC SUITES 4751 SF SHELL TO OFFICE COMM 0 NEW Applicant H HENDY ASSOCIATES SUITE 110 2415 CAMPUS DR 92612 949-851-0807 Owner Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# ISSUED 10/15/2003 SB 12/12/2003 12/12/2003 0836 12/12/03 0002 01 02 CGP 8582-15 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $663 60 Meter Size $0 00 Add'l Reel Water Con Fee $431 34 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $28 80 PFF $0 00 PFF (CFD Fund) $0 00 License Tax SO 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $000 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $2,495 77 $000 $000 $000 $1,79400 $000 $8300 $2000 $5750 $000 $3,587 63 $000 $000 $9,161 64 Total Fees $9,161 64 Total Payments To Date $579 49 Balance Due $8,58215 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired T>ovOctc^3 \ FOR OFFIC PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad CA 92008 1 . ;;i: PROJECJjNFORMATiON ;.Ji: W "•' .•••; •; J" FOR OFFICE USE ONLY PLAN CHECK NO EST VAL .J Plan Ck Deposit Validated By Date Address (include Bldg/Suite #)BusfheSt Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use .2 Proposed Use SQ FTDescription of Work 2; CONTACT PERSON (if different from applicant^ ..... ' v " # of Stories # of Bedrooms # of Bathrooms II To o A /Y ^ " <ww CityName ' Address APPLICANT JD. Contractor " O Agent for .Contractor •. Q Owner ^ State/Zip ' Telephone # . .......^r-v-^^,^-* ..,„»,.. i.™* •B^gerit terOwner Fax# 579.49 (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any Applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) - *f*S,L. Jfr-Oo-^-,^ 9^?/4-(<?4-OZz4- State/Zip Designer Name State License # HT WORKER'SiCOMPENSATION * U _ -J:'. ...:...:..: ... , ......„•*, I .' :...:...!,-,:,. '5:.:..,. .. .! ! Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations D I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued yNa^ I have and will maintain workers compensation as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued My 'workers compensation insurance carrier and policy number are Insurance Company _J6^^_^5fe_5^^&^/VL Policy No _t=- Expiration Date_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit \s issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers' compensation covejpege is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100,000), in adj*rfiont(/me cosUg£c0mpensationramages areuigsd-fer-tn Section 3706 of the Labor Code, interest and attorney's fees _DATE 7C pWNER-BUILbER DECLARATION1. '_ I hereby affirm that I am exempt from the Contractor s License Law for the following reason D I as owner of the property or my employees with wages as their sole compensation will d the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractors License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) D I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D YES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE .DATE WHITE File YELLOW Applicant PINK Finance RFRMlf APPLICATION CITX'OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad CA 92008 Page 2 of 2 [COMPLETE THIS SECTIONTO'^MO>^RiS/PaV77>«rBUIL''DING'PERMitSONLY" Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acf D YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' D YES D NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? • D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT [8~~CWSTiWCTIO7ilEf^WG~A^N^": ~~ '. ."--—- — - - -^ -^ -— .. ^ i hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(lj Civil Code) LENDERS NAME LENDER S ADDRESS [9 M^LJCANIOiOTFJCATION. ,,; :=N->^i;L.__^ ...„, _ _, ^^ ^tl^i*^. ...^:...;- __ „: ^^.••— ... • • ., ' | I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND OSHA An OSHA permit is required for excavations of 5 0" deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period ofl-SO days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE, j<g^a^ CSl—^—^O DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite,, Fire Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected By & Inspected Bv Inspected Bv Comments CB032848 EBD GROUP / SPEC SUITES 4751 SF SHELL TO OFFICE 2032 CORTE DEL NOGAL #100 NA Phone Water Dist / /? Date j/ / /^^^-^ Inspected '/3/OYy Date Inspected Date Inspected Date Permit Type Sub Type Lot 0 Approved ' — ~"~ Approved Approved 03/01/2004 Tl COMM ^Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 03/12/2004 Permit* CB032848 Title EBD GROUP / SPEC SUITES Description 4751 SF SHELL TO OFFICE Inspector Assignment TP 2032 CORTE DEL NOGAL 100 Lot 0 Type Tl Sub Type COMM Job Address Suite Location APPLICANT H HENDY ASSOCIATES Owner Remarks Total Time Phone Inspector Requested By Entered By CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Associated PCRs/CVs Inspection History Date 03/11/2004 03/10/2004 03/01/2004 02/06/2004 02/05/2004 02/04/2004 02/04/2004 02/04/2004 02/04/2004 02/03/2004 02/03/2004 02/02/2004 02/02/2004 02/02/2004 01/30/2004 01/30/2004 Description 89 89 89 34 34 14 24 34 44 14 44 14 34 44 14 34 Final Combo Final Combo Final Combo Rough Electric Rough Electric Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/W elding Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough Electric Act CA NR CO AP NR AP AP AP AP CO we CO CO CO NS NS Insp TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP Comments CALLED CONTRACTOR AND RESET FOR FRIDAY BLDG LOCKED MSB, SUB PNLS, TRANS T-CEIL CONDENSATES CEIL LITES DUCTS PLMNS T-CEIL T-CEIL City of Carlsbad Bldg Inspection Request For 03/01/2004 Permit# CB032848 Title EBD GROUP/SPEC SUITES Description 4751 SF SHELL TO OFFICE Inspector Assignment TP Type Tl Sub Type COMM Job Address 2032 CORTE DEL NOGAL Suite 100 Lot 0 Location APPLICANT H HENDY ASSOCIATES Owner Remarks Phone Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By NA Entered By CHRISTINE Act Comment ^2 Associated PCRs/CVs Inspection History Date Description 02/06/2004 34 Rough Electric 02/05/2004 34 Rough Electric 02/04/2004 14 Frame/Steel/Bolting/Welding 02/04/2004 24 Rough/Topout 02/04/2004 34 Rough Electric 02/04/2004 44 Rough/Ducts/Dampers 02/03/2004 14 Frame/Steel/Bolting/Welding 02/03/2004 44 Rough/Ducts/Dampers 02/02/2004 14 Frame/Steel/Bolting/Welding 02/02/2004 34 Rough Electric 02/02/2004 44 Rough/Ducts/Dampers 01/30/2004 14 Frame/Steel/Bolting/Welding 01/30/2004 34 Rough Electric 01/30/2004 44 Rough/Ducts/Dampers 01/16/2004 14 Frame/Steel/Bolting/Welding 01/16/2004 34 Rough Electric Act Insp Comments AP TP MSB, SUB PNLS, TRANS NR TP AP TP T-CEIL AP TP CONDENSATES AP TP CEIL LITES AP TP DUCTS PLMNS CO TP T-CEIL WC TP CO TP T-CEIL CO TP CO TP NS TP NS TP NS TP AP TP CEIL @ RESTRM AP TP CITY OF CARLSBAD BUILDING DEPARTMENT DATE Z///W NOTICE LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME + ' 5/ f FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? L__i YES FOR FURTHER INFORMATION, CONTACT ,£g.? •• 2 70 S __ ^rr: " ~ / / -X PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER ® EsGii Corporation In tPartnersnip with government for <Bui(<fing Safety DATE 12/3/03 Q APPLICANT JURISDICTION City of Carlsbad Q PLAN REVIEWER G FILE PLAN CHECK NO 03-2848 SET III PROJECT ADDRESS 2032 Corte Del Nogal PROJECT NAME EBD Group and Spec Suite - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes > The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person I | The applicant's copy of the check list has been sent to 3 Esgil Corporation staff did not advise the applicant that the plan check has been completed J Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person /<] REMARKS Applicant to add notes in red on E-2 to city held sets By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 11/21/03 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partnership with government for (RmUing Safety DATE 11/19/O3 """ " -=" "" OAEEUCANT""""""" JURISDICTION City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO 03-2848 SET II PROJECT ADDRESS 2032 Corte Del Nogal PROJECT NAME EBD Group and Spec Suite - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes * The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to H Hendy Associates 2415 Campus Dr Suite 110, Irvine, CA 92612 Esgil Corporation staff did not advise the applicant that the plan check has been completed IX3 Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted H Hendy Associates Telephone # 949-851-3080 Date contacted //1°) /o>(by fry) Fax # 949-851-0807 Mail _ Telephone Fax-' In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 11/10/03 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 03-2848 11/19/03 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO 03-2848 PROJECT ADDRESS 2032 Corte Del Nogal SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 11/10/03 11/19/03 REVIEWED BY Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform-Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit three new sets of prints to ESGIL CORPORATION B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo City of Carlsbad O3-2848 11/19/03 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets"can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will hot be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. The resubmitted plans contain the electrical plans for another project (Lobby A and Spec Suite) Please provide the correct electrical plans. 2 Please clarify the building data it indicates the building to be 2 stories'? The site plan indicates this to be a single story building? 5 Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans See above comment. 7 Please clarify the electrical single line to show new and existing See above comment 10 Show exit signs on the electrical lighting plan(s) As per Section 1003 2 8, provide two sources of power to exit signs and exit illumination Please clarify the plan they indicate a building emergency system'? See above comment EsGil Corporation In Partnership with government for <BuiCd\ng Safety DATE 1O/27/03 a APPLJQANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO O3-2848 SET I PROJECT ADDRESS 2032 Corte Del Nogal PROJECT NAME EBD Group and Spec Suite - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X| The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to H Hendy Associates ;A-w«-. V^r\ 2415 Campus Dr Suite 110, Irvine, CA 92612 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed fari t\0uK&»^ (v.M^ Person contacted H Hendy Associates Telephone # 949-851-3080 Date confici6cffc-g0-0S(by fix**) Fax # 949-851-0807 Mail-' Telephone-' Fax X In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 10/16/03 tmsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 1O/27/03 03-2848 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 03-2848 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 10/15/03 DATE INITIAL PLAN REVIEW COMPLETED 1O/27/03 JURISDICTION City of Carlsbad USE Office ACTUAL AREA 7040sf STORIES 1 HEIGHT OCCUPANT LOAD 98 DATE PLANS RECEIVED BY ESGIL CORPORATION 10/16/03 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must-be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O3-2848 10/27/O3 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC 2 Please clarify the building data it indicates the building to be 2 stories'? 3 Please clarify the section view of all new interior partitions detail 1 on sheet 1A- 61 Show a) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing 4 Provide a section view of the new soffits Show a) Specify manufacturer and approval number b) Show height of the soffit from floor, soffit to roof framing or floor framing 5 Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 6 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I - occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 7 Please clarify the electrical single line to show new and existing 8 Show the ampere interrupting capacity (AIC) ratings of the service and sub- service equipment NEC 110-9 9 If utilizing a series-rated system, note on plans "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" City of Carlsbad O3-2848 1O/27/O3 and "The overcurrent devices shall be AIC rated per manufacturers labeling of the electrical equipment" 10 Show exit signs on the electrical lighting plan(s) As per Section 1003 2 8, provide two sources of power to exit signs and exit illumination Please clarify the plan they indicate a building emergency system'? 11 Provide complete plumbing plans, including a) Complete the dram, waste and vent plans to show pipe sizing b) Please clarify the plans they show one tank on the isometric and msta-hot tankless water heaters on the floor plan plumbing notes UPC, Section 501 0 c) Please revise the waste isometric to show clean-outs at the upper terminals and sink locations 12 Show that water heater is adequately braced to resist seismic forces Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank) UPC, Section 5105 13 Show P & T valve on water heater and detail dram line route from P & T valve to the exterior UPC Section 608 4 14 Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details (the parking shown is non-compliant) etc To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction-list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad O3-2848 10/27/03 VALUATION AND PLAN CHECK FEE PLAN CHECK NO 03-2848 DATE 10/27/03 JURISDICTION City of Carlsbad PREPARED BY Doug Moody BUILDING ADDRESS 2032 Corte Del Nogal BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 7040 cb Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 211,200 211,200 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review ED Repetitive Fee Repeats Complete Review D Other (—1 Hourly Structural Only Hour* Esgil Plan Review Fee $891 521 $579 49 $499 25 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) TENANT IMPROVEMEN PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Oocs/Mislorms/Planniog Engineenng Approvals \ D Cl ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based oo building plancheck plan submittal Address ''Bldg Permit No Prepared by Date Checked by Date EDU CALCULATIONS List types and square footages fcir all uses Types of Use tf*C~l / Sq Ft /Units Types of Use Sq Ft /Units APT CALCULATIONS List types and square footages foj^JI uses Types of Use 7 S 1 / Sq Ft /Units Types of Use Sq Ft /Units EDU's EDU's ADT's ADT's FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1 PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS = $ D 2 TRAFFIC IMPACT FEE ADT's/UNITS Q 3 BRIDGE AND THOROL ADT's/UNITS UNIT/SQ FT D 5 SEWER FEE EDU's FEE/ADT = $ JGHFARE FEE >/IENT FEE (DIST #1 DIST #2 X FEE/ADT ZONE X FEE/SQ FT /UNIT DIST #3 ) = $ ^-- " = $ ^" BENEFIT AREA EDU's ^l» Q 6 SEWER LATERAL ($2,500) D 7 DRAINAGE FEES PLDA_ ACRES X X FEE/EDU HIGH = $_ = $. = $ /LOW X-' FEE/AC -$ Q 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION Word\Docs\Misforms\Fee Calculation Worksheet 1 of 2 Rev 7/14/00 Site Plan: [H CD CD 1 Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) CD D CD 2 Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines nan nan a aa 1 Applicability YES 2 Project complies YES Zoning: 1 Setbacks Front Interior Side Street Side Rear Top of slope 2 Accessory structure setb Front Interior Side Street Side Rear Structure separation 3 Lot Coverage NO NO Required Required Required Required Required lacks Required Required Required Required Required Required •*» Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown na an 4 Height Required Spaces Required. Shown Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required _ Shown _ Additional Comments rnTSurfc l-P c U *S 7T7K OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Clfe-bad Fire Department 032848 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 10/26/2003 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address H Hendy Associates 2415 Campus Drive Suite 110 City, State Irvine CA 92612 Plan Checker Job Name EBD Group Spec Suite Job # 032848 Job Address 2032 Corte Del Nogal Bldg# CB032848 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job# 1st Pnd 3rd 032848 FDFile# Other Agpnry in Requirements Category: Building Plan Requirement Pending 05 25 Exit Signs Section 1013 1 Where Required When two or more exits from a story are required by Section 1013 4, exit signs shall be installed at stair enclosure doors, horizontal exits and other required exits from the story When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction of egress EXCEPTIONS 1 Mam exterior exit doors which obviously and clearly are identifiable as exits need not be signed when approved by the building official 2 Group R, Division 3, and individual units of Group R, Division 1 Occupancies 3 Exits from rooms or areas with an occupant load of less than 50 when located within a Group I, Division 1 1, 1 2 or 2 occupancy or a Group E, Division 3 Day-Care occupancy Illumination Signs shall be internally or externally illuminated by two electric lamps or shall be of an approved self-luminous type Power Supply Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system Power to the other lamp shall be from storage batteries or an on-site generator set SHEET 1A-2 1 Add EXIT signs above doorway between Room 100 and 110, as well as Room 118 and 114 Page 1 10/26/03 L---Ip<to 111 X -3w x,,. 0 DC CC p^ -- LU <O 5 uj G. '-5 i- co ecn ^ 1 < ^ i £ °oRop sDL LU WOO. C,DC!- <A~HV x.>v -2i 4,t M CD O a LU onoo S <=>S ° CM «: o 0>- <il 0 ^) • j-~ Si *o 024-2004 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR04003 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title Applicant H HENDRY ASSOC 2032 CORTE DEL NOGAL CBAD PCR Lot# 0 $0 00 Construction Type VN EBD GROUP-REVISE MEN&WOMAN REST ROOM WALLS Owner Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 01/09/2004 MEL 02/04/2004 02/04/2004 2415 CAMPUS DR 92612 949 387-4662 Plan Check Revision Fee Additional Fees $12000 $000 Total Fees $12000 Total Payments To Date $000 Balance Due $12000 4528 02/04/0* 0002 ii COP Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired ,' PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave, Carlsbad CA 92008 / ^E FOrVOFFICEySE ON PLAN CHECK NO EST VAL Plan Ck Deposit. Validated By Date 1. PROJECT JMFORMATION .O^*M_ Address (include Bldg/Surte #)Business Name (at this address) I egal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use Proposed Use Description of Work SO FT # of Stories # of Bedrooms # of Bathrooms 2 Name Address ; Contractor]; o.EC Agent for Contractor'; City State/Zip Telephone # ^ent for Owner.... Fax # Name Address City State/Zip Telephone* (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any vic'ation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) _ ,\L-£L <^-s> ^cxLL^Azsc^*:, "24-VST <2j>^oD^<; -rs-r^llto 3f2d\»&,, CA 94^ <g^( -^<^3^> Name State License # l/1 \ C— <- Jj^u^-t L>OJi < Designer Name \ Address License Class L>~CVCi ^^-4 — 1£ <iAjvU?^ Address / City «5 rx^ "!£SIA)I./OV City State/Zip City Business License # Qe^ <9"Z-(s>/~Z- State/Zip Telephone # 9^T §S"/-::5«8D Telephone # State License # __[5!_2rrO~L__ 6 ••''.• "WORKER'S COMPpiSATION,-'"".-_,."•;-'.'"•""-'.-•''''. '"-"''; j.v! "'*•— •'.'''. •''.'-'-"-•.'' "< •;:, •-•'"• '*.'' Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations 0 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of '.he work for which this permit is issued D I have and will maintain workers compensation as required by Section 3700 of the labor Code for the performance of the work for which this permit is issued My work ir s compensation insurance carrier and policy number are Insurance Company Policy No _ Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [5100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued ' shall not employ any person in any Manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100,000), in addition to the cost of compensation, damages are provided foi In Section 3706 of the Labor Code interest and attorney s fees SIGNATURE DATE 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason D I as owner of the property or my employees with wages as their sole compensation will d the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractors License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) D I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE.DATE WHITE File YELLOW Applicant PINK Finance EsGil Corporation In (Partnership with government for (BuiCding Safety DATE 1/27/04 q^PPLlCANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-2848.PCR04-003 SET II PROJECT ADDRESS 2032 Corte Del Nogal PROJECT NAME EBD Group and Spec Suite - Revision to Floor Plan The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 1/21/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 ^ San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 EsGii Corporation In Partnership with government for (Building Safety DATE 1/20/O4 Q APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-2848.PCR04-003 SET I PROJECT ADDRESS 2032 Corte Del Nogal PROJECT NAME EBD Group and Spec Suite - Revision to Floor Plan The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person Xl The applicant's copy of the check list has been sent to H Hendy Associates 2415 Campus Dr Suite 110, Irvine, CA 92612 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted H Hendy Associates Telephone # 949-851-3080 Date contacted //20/of (by fyc) Fax # 949-851-0807 Mail (^Telephone Fax^ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB E] EJ D PC 1/12/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 1/2O/O4 O3-2848.PCR04-003 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 03-2848.PCR04-003 JURISDICTION City of Carlsbad OCCUPANCY B USE Office TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 1/9/04 DATE INITIAL PLAN REVIEW COMPLETED 1/20/04 ACTUAL AREA 7040sf STORIES 1 HEIGHT OCCUPANT LOAD 98 DATE PLANS RECEIVED BY ESGIL CORPORATION 1/12/04 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O3-2848.PCRO4-OO3 1/20/04 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Show that the minimum strike edge distances is provided at the level area on the side to which door 124 swings, per Section 1133B 243 a) >18" at interior conditions Show a clear level area, or landing for the relocated door to the storage room 108, per Section 1133B242 a) >60" in the direction of door swing To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad O3-2848.PCRO4-OO3 1/20/04 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad OO3 PREPARED BY Doug Moody BUILDING ADDRESS 2032 Corte Del Nogal BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN PLAN CHECK NO 03-2848.PCRO4- DATE 1/20/04 BUILDING PORTION Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Valuation Multiplier By Ordinance Reg Mod VALUE ($) + 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee $120 00 Type of Review C3 Repetitive Fee Repeats D Complete Review D Other m Hourly Structural Only 1 Hour* Esgil Plan Review Fee $9600 * Based on hourly rate Comments Sheet 1 of 1 macvalue doc Carlsbad Fire Department 04003 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 02/04/2004 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address City, State H Hendy Associates 2415 Campus Drive Suite 110 lrvmeCA92612 Plan Checker Job Name Job Address Job # 04003 EBD Group 2032 Corte Del Nogal Bldg# PCR04003 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards D Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2rH 3rd 04003 FD File # Other Agenr.y in Carlsbad Fire Department 04003 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 01/26/2004 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address H Hendy Associates 2415 Campus Drive Suite 110 City, State Irvine CA 92612 Plan Checker Job Name EBD Group job # 04003 Job Address 2032 Corte Del Nogal Bldg# PCR04003 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2nd 3rd 04003 FD File # Other Agpnr-.y in Carlsbad Fire Department °4003 less Faraday Ave Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report 01/26/2004 Reviewed by Name H Hendy Associates Address 2415 Campus Drive Suite 110 City, State Irvine CA 92612 Plan Checker 04003 Job Name EBP Group Job Address 2032 Corte Del Nogal Ste or Bldg No PLEASE REVIEW ATTACHED COMMENTS/CONDITIONS CAREFULLY AND RESUBMIT Requirements Category: Building Plan Requirement Pending 05 01 Project Data Provide complete address and suite designation Provide building construction information indicating occupancy classification, type of construction, number of stories, aggregate square footage, occupant load, and description of intended uses : Fire Department Notes- continue to reflect that OCFA is the authority having jurisdiction, please revise to reflect that Carlsbad Fire Department and its codes and ordinances are in effect Fire Department inspection shall include inspection of automatic fire sprinkler systems and egress systems Requirement Pending 0516- A/S Design Sprinkler system design shall be in accordance with standards set forth by the National Fire Protection Association and UBC Standards 38-1 and 38-2 Permits are required prior to installation Plans, specifications and calculations shall be certified by a licensed fire protection engineer or other person deemed competent by the Chief, and submitted in the name of a licensed sprinkler contractor Warehouse buildings for which no specific use, occupant, product, activity or storage array has been identified, shall be protected by sprinkler system designed to deliver water at the rate of 45 gallons per square foot, throughout a 3000 square foot design area 3 City of Carlsbad requires that all Fire Sprinkler Risers be made accessible by a full height man door properly identified This door may be of a minimum width of 24 inches but of full height (80 inches) ,, Additionally, the existing fire sprinkler system (shell building) shall remain intact and unobstructed \J3§uspended ceiling and wall sections shall not conflict with this protection Requirement Pending 05 32 Additional Requirements or Comments IT IS MOST IMPORTANT THAT THE ABOVE STATED COMMENTS/CONDITIONS ARE ,, ADHERED TO THIS BUILDING IS OF COMBUSTIBLE CONSTRUCTION AND THE CURRENT ' PROTECTION DESIGN IS BUILT ON THIS FACT Page 1 01/26/04 TITLE 24 REPORT Title 24 Report for: EBD GROUP & SPEC SUITES (BUILDING "C") 2032 CORTE DEL NOGAL CARLSBAD, CA Project Designer: H. HENDY ASSOCIATES 2415 CAMPUS DRIVE, SUITE 110 IRVINE, CA 92612 (949)851-3080 Report Prepared By: KEN PAIGE BUILDING MECHANICAL SYSTEMS, INC. 6 MORGAN, SUITE 118 IRVINE, CA92618 (949)587-1551 APPROVED Job Number:22003 of CARLSBAD- Date: 10/10/03 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards This program developed by EnergySoft, LLC (415) 883-5900 EnergyPro 31 By EnergySoft Job Number < < 0 S 1 ° gl £*§S3g2lg°cr 5 ft s !8 I^H: D w i I CC LU I LU IT I 8ww< fc Q Z L1J I « 'S O *a 0$ r43 ^ ^ 0w ^^ 1 ^ ^^ ^0 ,cx ^ au ^^v^ •^ X< ll ^3- ^ <r* — i >A ^OS v 4i %f > ^ .uSl^T^ l^Q^ ?^ —^ ^jy/)»^ O ^ Jf> J M- Ux 2- ® ^ 1 \i <T Cb> ^j U \ \^ \\^ ~v4 •?-^ «nT^ - Ur ± . \ -t ^ 0 ^ ^ Y ^ 0tl-^ -^&