Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2034 CORTE DEL NOGAL; ; CB042170; Permit
\j iS^fe^ City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB042170 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2034 CORTE DEL NOGAL CBAD Tl Sub Type Lot# $211,200 00 Construction Type Reference # ASM AFFILIATES 7040 SF SHELL TO OFFICE COMM 0 NEW Applicant SHERRY HANSSEN SUITE 100 4770 CAMPUS DR 92663 949-851-3050 Owner Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# ISSUED 06/04/2004 SB 07/06/2004 07/06/2004 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $891 52 Meter Size $0 00 Add'l Reel Water Con Fee $579 49 Meter Fee SO 00 SDCWA Fee $0 00 CFD Payoff Fee $44 35 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL SO 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $3,843 84 $000 $000 $000 $2,730 00 $000 $11800 $420 00 $241 00 $000 $2,575 00 $000 $000 $11,44320 Total Fees $11,443 20 Tota! Payments To Date $579 49 Balance Due $10,86371 5937 07/06/04 0002 01 02 SIGNATURE. CGP 10863« 71 uHPERMIT APPLICATIO t, CITY OF CARLSBAD BUILDTRGDEPAR .1635 Faraday Ave , Carlsbad, CA 92008 ; PROJECTJNFbRMAtlON FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By. Date CGF"-§29-49Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number ^ <z. y .AJ/Unit No Phase No Total #.of units Assessor s Parcel #Existing Use Proposed Use Description of Work '~ SQ FT 2 ^CONTACT PERSON (if fferent frorh applicant):; 47~7D #of St # of Bedrooms of Bathrooms Name ;3 .APPLICANT! QjContraotoflPPLICANTl. vUt£ Address ^gehtsfofiiContractofT; O Owner:; City I Agent/for Owner State/Zip Telephone /Fax Name Address City PROPERTY OWNER State/Zip Telephone # State/Zip 'Telephone ttNameAddressCity (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class /3 City State/Zip City Business License # / Telephone # 3 "7 Designer Name Address City State/Zip Telephone State License # 6 .2WORkERS;,*CbMPENSATION , " "•••"'T-^^I' i '""'""• ''""'., • ........ --r—:: •---• - •• -^ ^,-.,_" ^ ' ""^1^'"""" * Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued Q^ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is /Issued My worker s compensation insurance carrier and policy number are Insurance Company _, £*&•*¥€*S Cio^PS^&ir'Ms t +~S Policy No _ /-V J»^2 ,f/»T— Expiration Date >/'f° $ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE Ki..OWNER-BUILDER DECLARATION Ill LZTIT.. '.Ik—. L. , "I, -S' I..... :r ". ••:::^. ••-:»} I hereby affirm that I am exempt from the Contractor s License Law for the following reason O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement fj Y£S dNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE :F6^ :ii::-f:;..':.. -.mi"f^"". ' ".._&* «*P?':; 'I*---- :7^fc^Csii•,...:.:.i?e Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? d YES C3 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? (3) YES l~l NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES fj] NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER S NAME LENDER S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenped within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commencgnJty a penojd of 180 days (Section 106 4 4 Uniform Building Code) DATE (& ^ I 0 TAPPLICANT'S SIGNATURE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Lite /Fire Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected^ Bv >e7 - Inspected Bv Inspected Bv Comments CB042170 ASM AFFILIATES 7040 SF SHELL TO OFFICE 2034 CORTE DEL NOGAL ERIC Phone 7143924875 Water Dist /J Date $/ /<?//) F-^u^ — -^ Inspected / /^, $Date Inspected Date Inspected Date Permit Type Sub Type Lot 0 r Approved Approved Approved 08/19/2004 Tl COMM „ Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 08/25/2004 Permit# CB042170 Title ASM AFFILIATES 7040 SF SHELL Description TO OFFICE Inspector Assignment TP 2034 CORTE DEL NOGAL Lot 0 Type Tl Subtype COMM Job Address Suite Location APPLICANT SHERRY HANSSEN Owner Remarks Phone 7143924875 Inspector -y: Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs/CVs Requested By ERIC Entered By CHRISTINE Act Comment Inspection Historv Date 08/19/2004 08/18/2004 08/18/2004 08/16/2004 08/05/2004 08/04/2004 08/04/2004 08/02/2004 08/02/2004 08/02/2004 08/02/2004 08/02/2004 07/30/2004 07/30/2004 07/29/2004 07/27/2004 Description 89 34 34 34 84 14 34 14 17 24 34 44 14 17 17 17 Final Combo Rough Electric Rough Electric Rough Electric Rough Combo Frame/Steel/Boltmg/Welding Rough Electric Frame/Steel/Bolting/Weldmg Interior Lath/Drywall Rough/Topout Rough Electric Rough/Ducts/Dampers Fram e/Steel/Bolting/Welding Interior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Act CO AP AP AP AP CO CO AP AP we AP AP CA CA AP NR Insp TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP Comments SEE CARD SUB PNLS TRANS NEW MTR SECT SUB PNLS, TRANS T-CEIL (NEED TO PATCH 1 HR WALLS) CEIL LITES & DUCTS T-CEIL REST RM HARD CEIL REST RM REST RM HARD CEIL REST RM City of Carlsbad Bldg Inspection Request For 08/25/2004 Permit* CB042170 07/22/2004 14 Frame/Steel/Bolting/Welding AP TP 07/22/2004 34 Rough Electric AP TP 07/20/2004 84 Rough Combo NR TP 07/19/2004 14 Frame/Steel/Bolting/Welding PA TP 07/19/2004 24 Rough/Topout AP TP 07/19/2004 34 Rough Electric AP TP 07/16/2004 14 Frame/Steel/Bolting/Welding CO PS 07/16/2004 24 Rough/Topout CO PS 07/16/2004 34 Rough Electric CO PS 07/15/2004 14 Frame/Steel/Bolting/Welding NR RB 07/15/2004 14 Frame/Steel/Bolting/Welding AP RB 07/15/2004 24 Rough/Topout NR RB 07/15/2004 34 Rough Electric NR RB 07/15/2004 44 Rough/Ducts/Dampers WC RB 07/14/2004 44 Rough/Ducts/Dampers PA RB 07/07/2004 21 Underground/Under Floor AP TP 07/07/2004 22 Sewer/Water Service AP TP 07/07/2004 31 Underground/Conduit-Wiring AP TP Inspector Assignment TP FULL HT WALLS PER REV DTL REV SWITCH PLN SEE JOB CARD SEE ATTACHED NOTICE @ WALLS - MISSING ELECTRIC FRMG @ PLATFORM @ ROOF EQUIP WILL DO AT WALL FRMG @ WALLS OK TO INSULATE DUCTING CONNECTIONS City of Carlsbad Bldg Inspection Request For 07/16/2004 Permit* CB042170 Title ASM AFFILIATES 7040 SF SHELL Description TO OFFICE Inspector Assignment TP 2034 CORTE DEL NOGAL Lot 0 Type Tl Sub Type COMM Job Address Suite Location APPLICANT SHERRY HANSSEN Owner Remarks Phone 7143924875 Inspector Total Time Requested By ERIC Entered By ROBIN CD Description Act Comment 14 Frame/Steel/Bolting/Welding 24 Rough/Topout 34 Rough Electric Associated PCRs/CVs Inspection History Date Description Act Insp Comments 07/14/2004 44 Rough/Ducts/Dampers 07/07/2004 21 Underground/Under Floor 07/07/2004 22 Sewer/Water Service 07/07/2004 31 Underground/Conduit-Wiring PA RB OK TO INSULATE DUCTING CONNECTIONS AP TP AP TP AP TP CITY OF CARLSBAD BUILDING DEPARTMENT DATE "7 NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION PERMIT NO FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? I ! YES JRMATION, CONTACT UILDING IN PHONE CODE ENFORCEMENT OFFICER 08/17-'2G04 TCE 08*43 FAS 78S7468412 BERG ESTIMATES TO: FROM: ©001 Bergelectric Corp. • Contractors & Engineers FAXTRAKSMTTTAL DATS. 8/17/2004 Company: City Inspector Attention: Tim Phillips Telephone: Fax #: (760) 602-8560 Name: Jarred Dimock Telephone: (760) 746-1004 exf, 409 Fas #: (760) 741-7935 Email: jdimock@bergelectric.com JNo OJFPages: 3 (including transrmUai) Hard copy to follow L_j yes no SUBJECT; Tim, ASM Affiliates The two attachments are from the electrical engineer and the- tap manufacturei respectively, Thank You, Jarrod Di 650 Opper Street, Escondido, CA 92029 C10-#85046 08-17-2004 TUE 08 48 FAX 7G07468412 BERG ESTIMATES Yahoo' Mail - jairodditaock@yahoo.com Page 1 of 1 Pnnt - Cioee Window From PLHlNClt&sol com Date: use, i? Awg 2004 ii-3o-07 £OT Subject: F«c5. ASM To jarroddimock@yahoo com Forwarded Message from. PU'llNCigiao! corn Dsts: Tua, I/ Aiig 200* IO-15-4S ED"1" Subject ASM To. HTML Attachment _______ __________________ _____________ ____________ „ .. As the Electrical Engineers for the Carlsbad ASM project, we approve the use of parallel sVd conductors frorrt ih* undergraLind puii section to the new Switchboard, Pamela L. Knight President PLH & Associates, Inc. Bectnca! Engineers Tele (949) 727-06PO Fax. (949) 727-0733 Cell Phone (949) 338-0302 Email. plh@plhinc1 comorplhincl@aol.com httpV/us T417 mail yahoo com/>-m/ShowLetter?box-Inbox&M8gId=295-2089950_31870_. 8/17/2004 17.-2004 TUE 09'43 F*5 7607468412 1Z:15P BESG ESTIMATES ©003 P-O1 Pacific Electric, lac. JS -ttftacsi tost r (951)298-1563 Fax 42640 Rio Nedo • Temecula.Ce &23SO-3710 August 4, 2004 Bergelcctric 650 Opper Street tiscondido, Ca. 92029 Attention; Mr, Don Kune Reference Carfsbsd Park Office— 203* Cone Dei No&ai - Carlsbad, <"* 92000— <JOUA Tap Mr Kune. W« have investigated Iht existing S D 0 &L, pull sctlion for ths sddiileti ufd 400A tap for the new service rtt ih« referenced totavjon, Ogr firniings «nd msposrti«n are ns folio wi. 0 The existing pull section, manufactured approximately one year ago, contains line lugs for S f) <l«.&li. landing in lieu of the 1/2" studs normally required for ut<Jiiy pull sections, liach phd.sc contains four SOOktmil lugs pointing down The S*«iOn Mtirtg ss S00A I ^O^OS V 3PH 4W S D G.&L has iaitded on one of these, tugs. and based upon the UeclucaJ service standards two Jug positions mm* ha provided for iht 800A rating. 2) Sinix; S D.O.&E, has jsreviousjy se«pt«d the puil seciion design, based upon the face thm lh«y jiava landed Thejf cabl« on one of the available lugs, it is my proposal thai you turn one of the four lugs upward to be utilized for your new 400A service tap The lap exit should be out the top or top n$l« side y( lh« pull section, and tgbJcs mu-st not loop down into S D G &E. landing an a 3) We will noi provide our normal drawing and tap assemblies for thts application, based upon with Mr Steve Afasyta with S.D.C.&E. •i) Hleise usu ihi\ letter ,=« support for approval of this tap application y submitted, HA f ftoil) Carlwright cc Mr Steve Abeyra—S D G &R, EsGil Corporation In (Partnership with government for (Smftfing Safety DATE 7/1/04 QAPRUCANT JURISDICTION City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO O4-2170 SET II PROJECT ADDRESS 2034 Corte Del Nogal PROJECT NAME ASM Affiliates - TI [XJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck [~~| The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to X] Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 6/29/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with government for (Building Safety DATE 6/19/04 a APPLICANT JRI? JURISDICTION City of Carlsbad U>t^rREViEWER a FILE PLAN CHECK NO 04-2170 SET I PROJECT ADDRESS 2034 Corte Del Nogal PROJECT NAME ASM Affiliates - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person 1X3 The applicant's copy of the check list has been sent to H Hendy Associates / Sherry Janssen 4770 Campus Dr Suite 102, Newport Beach, CA 92663 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed [X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Sherry Janssen (v.jjfi Telephones 949-851-3080 Date contacted (t\Zile>y(by ^ ) Fax # Mail v_^Telephone — Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 6/8/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 City of Carlsbad O4-217O 6/19/04 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O4-2170 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 6/4/04 DATE INITIAL PLAN REVIEW COMPLETED 6/19/04 JURISDICTION City of Carlsbad USE Office Laboratory ACTUAL AREA 7040sf STORIES 1 HEIGHT OCCUPANT LOAD 80 DATE PLANS RECEIVED BY ESGIL CORPORATION 6/8/04 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ)- This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O4-217O 6/19/O4 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible The building official may require a technical report to identify and develop methods of protection from hazardous materials Section 307 1 6 2 In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or III-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour Such mechanical exhaust shall be taken from a point at or near the floor UBC, Section 1202 2 2 3 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 4 Please review for compliance and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 5 Provide the method of compliance as required by the energy building regulations (Title 24) for this tenant improvement • Provide documentation of the original energy design with modifications (additions or alternations) as applicable for this tenant improvement (If energy design was part of the "shell" permit) or • Provide a complete energy design as required for a new building When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to City of Carlsbad O4-217O 6/19/04 comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features 7 Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you Cfl Y OF CARLSBAD POLICIES AND PROCEDURE JUMBER: 80-6 SUBJECT: EFFECTIVE: 5/1/92 SECTION. BUILDING DEPARTMENT SUPERSEDES:80-6(9/10/80) 80-6(5/01/81) PURPOSE: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. INTENT: A. Maintain roof integrity. B. Prevent hazardous condition to firemen who must fight fire on the roof C. Provide an installation that is aesthetically sensitive to the building and the adjoining properties.' POLICY: 1. All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department. 2. All equipment shall be specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department. 3. All roof mounted equipment shall be on a platform which shall be an inteoral part of the roof-flashed and waterproofed. When a screen is approved, it shall have as few roof connections as possible and be structurally adequate. ^ All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official. 5. Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in general proximity. 6. Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official. 7. Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused openings properly sealec •to maintain roof integrity. *The architect should, through design, conceal the heating/AC unit and other equipment whether they are on the roof or elsewhere. initiated By:Approved B\ City of Carlsbad O4-217O 6/19/O4 VALUATION AND PLAN CHECK FEE PLAN CHECK NO O4-217O DATE 6/19/04 JURISDICTION City of Carlsbad PREPARED BY Doug Moody BUILDING ADDRESS 2O34 Corte Del Nogal BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 7040 cb Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 211,200 211,200 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review EH Repetitive Fee Repeats Complete Review D Other r-i Hourly Structural Only Hour* Esgil Plan Review Fee Comments $891 52 $579 49 $499 25 Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB OH in 0 DATE 0&-68-OCf ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) OTHER PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER DATE &&-OG-01 ENGINEER DATE (f Docs/MlsforrrWPIannmg Engineering Approvals ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal Address /JO4ai Prepared by Date Bldg Permit No Checked by Date EDU CALCULATIONS- List types and square footages for all uses Types of Use Ste/l -te Q«fifrts. Sq Ft /Units Types of Use _ Sq Ft /Units APT CALCULATIONS. List types and square footages for all uses Types of Use 5M 4g Q&rfr Sq Ft /Units Types of Use _ Sq Ft /Units EDU's EDU's ADT's ADT's gl 5b FEES REQUIRED WITHIN CFD (no bridge & thoroughfare fee in District #1 , reduced Traffic Impact Fee)D NO D 1 PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS =$_ TRAFFIC IMPACT FEE ADT's/UNITS FEE/APT =$ D D *• D D 3 BRIDGE AND THOROUGHFARE FEE ADT's/UNITS 4 FACILITIES MANAGEMENT FEE UNIT/SQ FT • 5 SEWER FEE EDU's £,'0& BENEFIT AREA C^\ EDU's 3- ^& 6 SEWER LATERAL ($2,500) 7 DRAINAGE FEES PLDA ACRES (DIST #1 DIST #2 X FEE/ADT ZONE X FEE/SO FT /UNIT X FEE/EDU ^^~ X FEE/EDU 1 0^ HIGH /LOW X FEE/AC DIST #3 ) =$ =$ =1 £317.5-0 __s ^ ^ = $ = $ D 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION F \FEE CALCULATION WORKSHEET doc 1 of 2 Rev 7/1 4/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $ * NOTE This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits 7-oVoCs} , -35;. /OO 1>J w. 2 of 2 F (FEE CALCULATION WORKSHEET doc Rev 7/14/00 Carlsbad Fire Department 042170 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 06/23/2004 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address H Hendy Associates 241 5 Campus Drive Suite 1 1 0 City, State Irvine CA 92612 Plan Checker Job Name ASM Affiliates Job # 042170 Job Address 2034 Corte Del Nogal Bldg# CB042170 Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards D Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2nd 3rd 042170 FDFile# Other Agenr.y ID Carlsbad Fire Department 042170 1635 Faraday Ave ^. Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 06/15/2004 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address City, State H Hendy Associates 2415 Campus Drive Suite 110 lrvineCA92612 Plan Checker Job Name Job Address Job# 042170 ASM Affiliates 2034 Corte Del Nogal Bldg# CB042170 Ste orBldg No i—i Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Approved The item you have submitted for review has been approved subject to the Subject to attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FDJob# 1st 2nd 3rd 042170 FDFile# Other Agenny in ^ Carlsbad Fire Department 04217Q less Faraday Ave Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report 06/15/2004 Reviewed by Name H Hendy Associates Address 2415 Campus Drive Suite 110 City, State Irvine CA 92612 Plan Checker Job Name ASM Affiliates Job Address 2034 Corte Del Nogal _ Ste or Bldg No Please complete attached "Statement of Intended Use" for further consideration of submitted plans Requirements Category: Building Plan Requirement Pending 05 32 Additional Requirements or Comments APPROVAL OF THESE PLANS IS PENDING THE COMPLETION AND SUBMITTAL OF THE ATTACHED 'STATEMENT OF INTENDED USE1 OUR SPECIFIC CONCERN IS THE INSTALLATION OF A LAB AND THE SPECIFIC USE OR TYPE OF LAB Pagel 06/15/04 H HendyASM LOCATION BRANDOW & JOHNSTON ASSOCIATES CONSULTING STRUCTURAL ENGINEERS 1660 W THIRD ST LOS ANGELES, CALIFORNIA 90017 TELEPHONE 484-8950 AREA CODE 213 02271 6/4/2004 M Fotch (FILE G \04\04271\ENG\[97UBC-MECHEQUIP^xls]Economizer) STRUCTURAL CALCULATIONS FOR ROOF EQUIPMENT ASM AFFILIATES Carlsbad Office Park, Building E 2034 Corte del Nogal Carlsbad, California H HendyASM Unit Loads BRANDOW & JOHNSTON ASSOCIATES CONSULTING STRUCTURAL ENGINEERS 1660 W THIRD ST LOS ANGELES, CALIFORNIA 90017 TELEPHONE 484-8950 AREA CODE 2 02271 6/4/2004 M Fotch (FILE C \04\04271\ENG\ICOVER xlsjcover) ROOF ROOFING PLYWOOD SHEATHING 2X RAFTERS 26" TJL @ 32" o c Sprinklers CEILING &MISC 60 PSF 20 PSF 20 PSF 22 PSF 1 0 PSF 48 PSF SUM 18 0 PSF TOTAL DL LL 18 0 PSF 20 0 PSF (Reducible) LOCATION BRANDOW & JOHNSTON ASSOCIATES CONSULTING STRUCTURAL ENGINEERS 1660 W THIRD ST LOS ANGELES CALIFORNIA 9OOI7 TELEPHONE 484 89SO AREA CODE 213 SHEET NO ">, PC:- _--_~ .005. < 1_J cb s K | tt 0)0 01 o *5 oi O 0 ^8 O *8o 08 0 ^8o oo 0 oo 0 8 O oo 0 oo 0 oo o S°88 c "uco (? o 08o o §O 00 0 o o o o o oo o o o o o 888 000 888 0 0 O 888 O 0 O 888 O O O 888 0 O 0 o o o oo o o o 0000 o o0 0 0 0 S o0 0 0 88 o o o oo o O 0 §o0 O 0 O O0 0 0 O 88 O O S o0 0 0 oo 0 ooo 8o oo 0 oo 0 oo 0 ooo 8 0 - £ o dc «dCO <Js d 3° CD r-m co O Tf CO *-r*- oo CO T- O 0 0 O) CD*— o 0 0 B o0 0 O h- f- O 0 CO CD 0 0 Sogg f£ oo CO s so of- o CO<oo 8o CM 0 o> o 8o 8 O oo 0 8 O oo 0 oo 0 oo 0 8 i S0 jg 8 I S= O Oo 0 8 O 8 O 8 O 88 O oo 0 0 oo 0 s 8 ^~ COCO 0 ooo oo *~ §o 8o "w to 9- 9- T- -r- n C/l If) V) V)a a. a. Q. o co o o QUJa: oooooooo oooooooo i O O O O O O O'oooooooo • in r- ino o o ooo ; co co co•sssooo II II II IIX X X X O CD -^ O r- CD°s»°»^r*- r*- CM *? fc-?-45X S E CC Ela: I O K I*ej2 'S88 CD O CDCO T- CO U a ^QcZacLCLaiLai 8° oUJ<a O (O CD O O f . UJa PROJECT ASM Tl LOCATO. [TEM Mech Anchorage SHEET NO . BRANDOW & JOHNSTON ASSOCIATES /^T JOB HO ' CONSULTING STRUCTURAL ENGINEERS 04271 DATE 20301 S W Birch Street, Newport Beach, California 92660 6/4/04 (949)476-8319 Fax (949) 955-0794 bja@bjase com M Fo(ch (FILE G \04\04271\ENG\l97UBC-MECHEQUIP-2 xls]Economizer) EQUIPMENT MARK Roof A / C Units EQUIPMENT INFO ^ Lonath H.) or Width(B) Total Weight 325 Ib x Length (L) 47 inch Width (B) 31 inch Area 10 1 sq Dist Load 40 2 psf H, 37 0 inch H2 60 inch H3 00 inch HCG 130 inch Note HCG IS assumed to be H,/2 unle SEISMIC LOADS Wp 406 25 Ibs ap 10 Na 10 Ca 044 IP 15 Rp 30 hx 20 feet hr 20 feet WIND LOADS 1 2b = 40626 * ...... p es I es • Wp ~r~ "^""^® es HCG C& I ., Mech Equipes 1 RI Manuf Curb R2 ss specified 1 1^3 Roof Platform / Curb R" t •\ t •\ A \ k HI r H2 r ? Table 16-O O Ol O Table 16-S — (E) Roof Framing Table 1 6-Q Fp = [ ap Ca lp (1 +3*hx/hr) / Rp ] * Wp Table 16-K Fp = 088*WP= 358 Ibs Table 16-O MAX Fp 2 64 *WP = 1072 5 Ibs MINFP 046*WP= 187 688 Ibs USE Fp= 358 Ibs WORKING STRESS Fp = 0 63 *Wp = 255 Ibs GOVERNS Wind Speed 70 mph Exposure C P=CeCqlwqs = 19 9 psf 126 psf 16 feet 113 Table 16-G 140 Table 16-H 100 Table 16-K Area =392ftx308ft= 120764 sf Fw= 241 Ibs UseF =255 Ibs Number of anchor Points MAX ANCHOR LOADS (AT TOP OF ROOF PLATFORM / CURB) VEQ= Fp/N PEQ= FPx(HCG+H2)/(NLxB) PD+EQ= PEQ + WP/N Long Side NL = Short Side Ns = Total N = 2 2 4 = (FPx(HCG-fH2)- 9WpxB/2)/(NLxB) = VEQ = PEQ = PD+EQ = PSO-EQ = SHORT DIR 64 Ibs 78 Ibs 180 Ibs -13 Ibs LONG DIR 64 Ibs 52 Ibs 153 Ibs -40 Ibs Horizontal Vertical Down No Uplift NOTE 1 Weight of Manufacturer's curb is included in total weight, Wp 2 When Wind governs, the 1 25 factor is not used in calculating the uplift force