HomeMy WebLinkAbout2035 ALGA RD; ; CB020155; Permit03-1 8-2002
City of Carlsbad
1635 Faraday Av Carlobad, CA 92008
Building Inspection Request Line (760) 602-2725
Residential Permit Permit No: CB020155
Job Address: 2035 ALGA RD CBAD
Permit Type: RESDNTL Parcel No: Sub Type:
Valuation:
2151103200 Lot #:
$33,990.00 Construction Type:
Occupancy Group:
# Dwelling Units: Reference #:
Bedrooms: 0 Structure Type:
Project Title: 0 Bathrooms:
VALENTI RES-330 SF OFFICE ADD
CONSOLIDATED CONSTRUCTION STE 6-1
VISTA CA 92084
1020 SOUTH SANTA FE
760 630-51 54
RAD
0 VN
Status: ISSUED
Applied: 01/14/2002
Plan Approved: 0311 8/2002
Issued: 03/18/2002
Entered By: RMA
0 Inspect Area:
Plan Check#: Orig PC#:
Owner:
VALENTI LAWRENCE DBANITA Y
2035 ALGA RD
CARLSBAD CA 92009
3144 03/18/02 0002 01. 02 CGP 380 * 13
Total Fees: $552.53 Total Payments To Date: $172.40 Balance Due: $380.13
Add'l Building Permit Fee
Building Permit
Plan Check
Addl Plan Check Fee
Plan Check Discount
' Park in Lieu Fee
: Strong Motion Fee
.' Park Fee
" LFMFee
Bridae Fee Othgr Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Addl Renewal Fee Other Building Fee
Pot. Water Con. Fee
Meter Size
Addl Pot. Water Con. Fee Recl. Water Con. Fee
$265.23
$0.00
$172.40
$0.00 $0.00 $3.40
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00 $0.00 $0.00
$0.00
$0.00
$0.00
Meter Size
Addl Recl. Water Con. Fee
Meter Fee SDCWA Fee CFD Payoff Fee PFF
PFF (CFD Fund)
License Tax
Traffic Impact Fee License Tax (CFD Fund)
Traffic Impact (CFD Fund)
Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing InLieu Fee
Sewer Fee
Master Drainage Fee
Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00 $0.00
$0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
$63.00
$0.00
$20.00
$28.50
$0.00
$0.00 $0.00 $0.00
$552.53
$0.00
City of Carlsbad Bldg Inspection Request
For: 09/11/2002
Permit# CB020155 Inspector Assignment: PY
Title: VALENTI RES-330 SF OFFICE ADD
Description:
Type: RESDNTL Sub Type: RAD
Job Address: 2035 ALGA RD
Suite: Lot 0
Location:
APPLICANT CONSOLIDATED CONSTRUCTION
Owner: VALENTI LAWRENCE D&ANITA Y
Remarks:
Phone: 7607577844
Inspector:
Total Time: Requested By: NICOLE
Entered By: GIOVANNA
CD Description Act Comments
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical 1 .-
Associated PCRslCVs
Date Description
08/16/2002 89 Final Combo
05/17/2002 15 RwWReroof WC RC
05/17/2002 17 Interior Lath/Drywali AP RC
05/16/2002 14 Frame/Steel/BoitingMelding WC RC
05/16/2002 17 Interior LaWDrywall CO RC NAIL SPACING TOO WiDE -MANY MISSED AREAS
05/07/2002 16 insulation
05/07/2002 84 Rough Combo
05/03/2002 13 Shear PanelslHD's
05/03/2002 14 Frame/Steel/BoltingNlding AP PY
04/11/2002 13 Shear PaneldHD's WC RC
0411 1/2002 15 RooWRermf
03/29/2002 11 FtglFoundatiorVPiers
AP RC OK TO COVER - TRUSSES OK
AP RC OKTO POUR
03/27/2002 24 Roughfropout AP RC OKTOCOVER
InsDection History
Act lnsp Comments
CO PY NEED SMOKE ALARMS UPGRADE
AP RC OKTO DRYWALL
AP RC
AP PY NAIL STRAPS AT DOOR
7 EsGil Corporation
In partncrsfiip witfi ~ouernmnt for i5’uil;iingSafety
DATE: 03/14/02
JURISDICTION: Carlsbad
PLAN CHECK NO.: 02-155
PROJECT ADDRESS: 2035 Alga Road
SET 111
w a PLAN REVIEWER
a FILE
PROJECT NAME: Room Addition for Valente Residence
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
[XI The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant‘s copy of the check list has been sent to:
[XI Esgil Corporation staff did not advise the applicant that the plan check has been completed
ff did advise the applicant that the plan check has been completed.
Telephone #:
Fax #:
Fax In Person
lete special inspection form with name of inspector for retro fit bolts.
Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 03/07/02 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576
EsGil Corporation - -
Zn Tartnersfiip witfi Fovernment for 5ui(ding Safety
DATE: 02/22/02
JURISDICTION: Carlsbad
PLAN CHECK NO.: 02-155
PROJECT ADDRESS: 2035 Alga Road
SET: I1
0 PLAN REVIEWER
0 FILE
PROJECT NAME: Room Addition for Valente Residence
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[XI The applicant's copy of the check list has been sent to:
Robert Kurbis
3801 Buena Creek Vista, Ca. 92084
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
[XI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Robert Kurbis [kr. w) Telephone #: (760) 801-7167
Date contacted: 2 1 Ui0L(by: p- ) Fax #:
Mail "'Telephone J Fax In Person 0 REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 0211 4/02 lmsrnll.do1
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 02-155
02/22 f 02
RECHECK PLAN CORRECTION LIST
PROJECT ADDRESS: 2035 Alga Road SET: I1
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 02/14/02
DATE RECHECK COMPLETED:
02/22/02
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the'Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
6. The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
C. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
OYes QNo
Carlsbad 02-155
16. Line B is noted as existing. This wall still needs to be reviewed as additional 2 kips will be
02/22/02
added to this line and with room addition the existing stucco shear will be removed at
both lower floor and partial removal at upper floor to allow for roof framing. Additional 5
ft of shear was added with hold downs. These will need to be retrofitted and detail
81S3 which was crossed out previously now appears to apply and needs to be
referenced to foundation plan . Is 2nd floor level still ok with removal of stucco for
addition due to added roof framing.
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, Le., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate: Yes 0 No t3
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review items,
please contact Ray Fuller at Esgil Corporation. Thank you.
Carlsbad 02-155
02/22/02
I BUILDING DEPARTMENT
NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION
Do Not Remove From Plans
Plan Check No. 02-155
Job Address or Legal Description 2035 Alga Road
Owner Address
You are hereby notified that in addition to the inspection of construction provided by the Building
Department, an approved Registered Special Inspector is required to provide continuous inspection
during the performance of the phases of construction indicated on the reverse side of this sheet.
The Registered Special Inspector shall be approved by the City of Carlsbad Building
Department prior to the issuance of the building permit. Special Inspectors having a
current certification from the City of San Diego, Los Angeles, or ICBO are approved as
Special Inspectors for the type of construction for which they are certified.
The inspections by a Special Inspector do not change the requirements for inspections by
personnel of the City of Carlsbad building department. The inspections by a Special
Inspector are in addition to the inspections normally required by the County Building
Code.
The Special Inspector is not authorized to inspect and approve any work other than that for which he/she
is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate
materials, structural changes, or any requests for plan changes. The Special Inspector is required to
submit written reports to the City of Carlsbad building department of all work that he/she
inspected and approved. The final inspection approval will not be given until all Special Inspection
reports have been received and approved by the City of Carlsbad building department.
Please submit the names of the inspectors who will perform the special inspections on each of the items
indicated on the reverse side of this sheet.
(over)
Carlsbad 02-155
02/22/02
SPECIAL INSPECTION PROGRAM
ADDRESS OR LEGAL DESCRIPTION:
PLAN CHECK NUMBER: OWNER'S NAME:
I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I,
or the architectlengineer of record, will be responsible for employing the special inspector(s) as
required by Uniform Building Code (UBC) Section 1701 .I for the construction project located at
the site listed above. UBC Section 106.3.5.
Signed
I, as the engineedarchitect of record, certify that I have prepared the following special inspection program as
required by UBC Section 106.3.5 for the construction project located at the site listed above.
en#nurYIIChw.&.I 8 SllMvn IYn
Signed
I. List of work requiring special inspection:
0 Soils Compliance Prior to Foundation Inspection 0 Field Welding 0 Structural Concrete Over 2500 PSI 0 High Strength Bolting 0 Prestressed Concrete ExpansionlEpoxy Anchors 0 Structural Masonry 0 Sprayed-On Fireproofing 0 Designer Specified 0 Other
2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above:
A.
0.
C.
3. Duties of the special inspectors for the work listed above:
A.
C.
Special inspectors shall check in with the City and present their credentials For approval -0 beginning work on the job Site.
:.
X
* *
n c
EsGil Corporation - -
ln Tartnrrship with ~ovcrnmcnt for !BuiGtingSafcty
DATE: 01/23/02
JURISDICTION: Carlsbad
PLAN CHECK NO.: 02-155
PROJECT ADDRESS: 2035 Alga Road
SET: I
0 APPLICANT
0 PLAN REVIEWER
0 FILE
PROJECT NAME: Room Addition for Valente Residence
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Robert Kurbis
3801 Buena Creek Vista, Ca. 92084
0 Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Robert Kurbis Telephone #: (760) 801-7167
Date contacted: I 123 10;. (by: ) Fax #:(7c00).7S..l 7SG6
Mail -Telephone J Fav In Person
REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 01/15/02 trnsrnH.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
.
Carlsbad 02-155
01 123102
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PROJECT ADDRESS: 2035 Alga Road
FLOOR AREA: STORIES: 1
Addition 330
HEIGHT: 1 lft per UBC
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION: 01/14/02 ESGlL CORPORATION: 01/15/02
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Ray Fuller
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 1998 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed UD the recheck Drocess. please note on this list (or a CODY) where each
correction item has been addressed. i.e., plan sheet number. specification section. etc.
Be sure to enclose the marked UP list when you submit the revised plans.
Carlsbad 02-155
01 123102
1.
2.
3.
PLANS
Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for commerciallindustrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculationsheports directly to the
City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009,
(760) 602-2700. The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)
560-1468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete.
Plans, specifications and calculations shall be signed and sealed by the
California state licensed engineer or architect responsible for their preparation.
Final sets.
On the cover sheet of the plans, specify any items requiring special inspection, in
a format similar to that shown below. Section 106.3.2.
REQUIRED SPECIAL INSPECTIONS
In addition to the regular inspections, the following checked items will also require
Special Inspection in accordance with Sec. 1701 of the Uniform Building Code.
ITEM REMARKS
CONCRETE FOUNDATION Per notes on S-I. . STEEL REBAR . ANCHOR BOLTS
4. When special inspection is required, the architect or engineer of record shall
prepare an inspection program which shall be submitted to the building official for
approval prior to issuance of the building permit. Please review Section
106.3.5. Please complete the attached form.
5. Provide pages numbers to architectural sheets.
6. Specify use of room addition. This room as designed is a potential bedroom due
to closets and bathroom. Section 106.3.3.
7. Specify if there any existing windows where addition is to take place.
Carlsbad 02-155
01/23/02
8.
9.
IO.
11.
12.
13.
14.
15.
16.
17.
Expand smoke detector note on sheet 2 to state "hallways leading to bedrooms
and on each floor."
Specify minimum 30" clear width for water closet on sheet 2.
Are new footings to be doweled into existing footings and if so note number, size
of rebar and depth of embedment. If special inspection is required then note this
on the plans and add to requirements above and on S-I.
Line 2 is to have HD5As and 2As are noted instead on sheet 2.
Truss numbers to be on the plans or sticky back layout.
Could not locate where detail 2/S-3 applies as not crossed out on plans.
Show edge nailing of roof diaphragm to blocks on section on sheet 2.
Note on plans which walls are to be ballooned framed. Detail or note all shear to
extend to roof sheathing.
Line B is noted as existing. This wall still needs to be reviewed as additional 2
kips will be added to this line and with room addition the existing stucco shear
will be removed at both lower floor and partial removal at upper floor to allow for
roof framing.
FAU cannot be located inside a potential bedroom or closet off a bedroom or in a
bathroom. Attic space is not deep enough to allow for minimum 30" head
clearance required.
To speed up the review process, note on this list (or a copy) where each correction
tern has been addressed, i.e.. plan sheet, note or detail number, calculation page,
?tC.
=lease indicate here if any changes have been made to the plans that are not a
-esult of corrections from this list. If there are other changes, please briefly describe
:hem and where they are located in the plans.
-lave changes been made to the plans not resulting from this correction list? Please
ndicate: Yes 0 No R
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
3rive. Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
:o perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
IOU.
Carlsbad 02-155
01/23/02
- City of Carlsbad
BUILDING DEPARTMENT
NOTICE OF REOUIREMENT FOR SPECIAL INSPECTION
Do Not Remove From Plans
Plan Check No. 02-155
Job Address or Legal Description 2035 Alga Road
Owner Address
You are hereby notified that in addition to the inspection of construction provided by the
Building Department, an approved Registered Special Inspector is required to provide continuous
inspection during the performance of the phases of construction indicated on the reverse side of
this sheet.
The Registered Special Inspector shall be approved by the City of Carlsbad Building
Department prior to the issuance of the building permit. Special Inspectors having a
current certification from the City of San Diego, Los Angeles, or ICBO are approved as
Special Inspectors for the type of construction for which they are certified.
The inspections by a Special Inspector do not change the requirements for inspections by
personnel of the City of Carlsbad building department. The inspections by a Special
Inspector are in addition to the inspections normally required by the County Building
Code.
The Special Inspector is not authorized to inspect and approve any work other than that for which
he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept
alternate materials, structural changes, or any requests for plan changes. The Special Inspector is
required to submit written reports to the City of Carlsbad building department of all work that
he/she inspected and approved. The final inspection approval will not be given until all Special
Inspection reports have been received and approved by the City of Carlsbad building department.
Please submit the names of the inspectors who will perform the special inspections on each of the
items indicated on the reverse side of this sheet.
(over)
L .' - -,
fl
i
Carlsbad 02-155
01/23/02
SPECIAL INSPECTION PROGRAM
ADDRESS OR LEGAL DESCRIPTION: Jo 3 < AL~A &9. CFI&SRAap
PLAN CHECK NUMBER 02- OWNERS NAME: A.AR/Lf r/A L mrc- 9- 9..
I, as the owner, or agent of the owner (contractors may employ the special inspector),
certify that I, or the architectlengineer of record, will be responsible for employing the special
inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction
BC Section 106.3.5.
at I have prepared the following special inspection
program as required by UBC Section 106.3.5 for the construction project located at the site listed above.
in#r*.WAmM.a'lSmI L (ilg".tun wu.
1. List of work requiring special inspection:
0 Soils Compliance Prior to Foundation Inspection 0 Field Welding 0 Structural Concrete Over 2500 PSI 0 High Strength Bolting 0 Prestressed Concrete ExpansionlEpoxy Anchors 0 Structural Masonry 0 Sprayed-On Fireproofing 0 Designer Specified Other ?e.-+ +beef 5-1
2. Name(s) of individual@) or firm@) responsible for the special inspections listed
above:
A. B*S .cd/y,d~/dk ' /B// -A 57. #fl&Sb: &$A,"
B. 0- -?ish -
C.
3. Duties of the special inspectors for the work listed above:
- Y..i"422/
A. ?ec bk-5 on S-I
B.
C.
Special inspectors shall check in with the City and present their credentials for approval e&& beginning Work On the job
site.
Carlsbad 02-155
01/23/02
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 02-155
PREPARED BY: Ray Fuller DATE: 01/23/02
BUILDING ADDRESS: 2035 Alga Road
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
lir Conditioning
Fire Sprinklers
TOTAL VALUE
$265.231
33,990
Jurisdiction Code By Ordinance CB
Bldg. Permit Fee by Ordinance v
Plan Check Fee by Ordinance
Type of Review: Qmplete Review 0 Structural Only
v
I I
0 Other
0 Hourly 71 Hour
Esgil Plan Review Fee
Comments:
Sheet 1 of 1
macvalue.doc
~ City of Carlsbad
PROJECT DESCRIPTION: 12k mo
ASSESSORS PARCEL NUMBER: 21 71 I 10.5 2 EST.VALUE: 33 4% I
ENGINEERING DEPARTMENT
APPROVAL DENIAL
The item you have submitted for review has been
approved. The approval is based on plans, Please see the attached report of deficiencies
marked with 0. Make necessary corrections to plans information andlor specifications provided in your or specifications for compliance with applicable
this date, including field modifications. must be submittal: therefore any changes to these items after codes and standards. Submit corrected plans andlor
reviewed by this office to insure continued specifications to this office for review.
conformance with applicable codes. Please review
with instructions in this report can result in carefully all comments attached, as failure to comply
suspension of permit to build.
w Right-of-way permit is required prior to
construction of the following improvements: By: Date:
By: Date:
By: Date:
AlTACHMENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
ENGINEERING DEPT. CONTACT PERSON
Name: KATHLEEN M. FARMER
Cily of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: (760) 602-2741
CFD INFORMATION
Parcel Map No:
Lots:
Right-of-way Permit Application Recordation:
Right-of-way Permit Submittal Checklist Carlsbad Tract: and Information Sheet
Sewer Fee Information Sheet A4
n\woR~~ecdcl@arlsbad, CA 920047314 (760) 602-2720 0 FAX (760) 602Ps3fM @
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. Cd> - , Address
Planner >kP_ Phone (760) 602- t;PF
APN: - 2/y+/o $A 1
reject & Use: /e Net Project Density:
Gedai pian: I[ fl Facilities
CFD (in/out) #-Date of participation: Remaining net dev acres:-
Circle One (For non-residential development: Type of land used created by this permit: )
Legend: Item Complete 0 Item Incomplete - Needs your action
Environmental Review Required: YES - NO - TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES - NO - TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone AssessmentlCompliance
Project site located in Coastal Zone? YES-
CA Coastal Commission Authority? YES
ontact them at - 7575 Metropolitan Drive, Suite
NO-
" (at minimum Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
lnclusionary Housing Fee required: YES- NO8
(Effective date of lnclusionary Housing Ordinance - Ma 21, 1993.)
Data Entry Completed? YES -
(AIPIDs, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing
Y/N, Enter Fee, UPDATE!)
NO -
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01
Fun
P"
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-
of-way width, dimensional setbacks and existing topographical lines (including all side and
rear yard slopes).
2. Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
1. Applicability: YES
2. Project complies YES- NO
Zoning:
No&
1.
2.
3.
4.
5.
Setbacks: -1 "
Front: Required 0 Shown - CY I
Interior Side: Required 10 Shown r3 .6
Street Side: Required Shown - /
Rear:
Top of slope: Required -21 Shown 3 f
Required - Shown -
Accessory structure setbacks:
Front: Shown
Interior Side: Required Shown
Required Shown
Rear: Required Shown
Str-separation: Required Shown v
Lot Coverage:
Height:
Required kz.'c) Shown %g
Required Shown 630 '
Parking: Spaces Required 9 Shown -5
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01
I STRUCTURAL CALCULATIONS I
REVISION DATES:
THIS SET OF CALCULATIONS HAS A TOTAL OF 13 PAGES.
GLUE-LAMJNATEDBEAMS:
(G- .. 24F-V8, DF/DF)
BASIS FOR DESIGN: CConr9.nea)
MATERAm (conthapcd)
0 &aow,sM.arcn,AndHadm: MgI8SWLmb
4~6andamSlles: Dougla5FirLarchN0.2 Fb=mp& Fv-9Spai E=I.6xlO psi
6x6aad Wider: Dougtaa Fin WNo. 1
Fb= 13Mpai Fv- 85 psi, E=1.6x10 psi
woodPortrnIldTimberE DongbF&LarchNal
Fc-lOOOpsi, Fv=85psi, Es1.6~10 psi
stmctmmlst.dl: Stod Grade
Fb-700& Fc==850& Fv-95& E=lAxlO psi
Dougla~FirLarebConrt.Grde
4X6alUiwider: PC- lOOOpsi, Fvp95Spsi E~1.5~10 psi
FRAMING CONNECFORS? Use approved hmbg cmwtom, SIMPSON, or equal.
NAIIJNGGULFh
USO TABLENO. 23-II-&I, 1997, peSe 2-282
2182 El Camho Real. Suite 103, Oceanside, CA 92054 Phone (760) S9-8566 Fex (780) 508-8838
5 OF 13
Dosign Check Calculation Sheet
.om. (s*p.r.orPrrl
I Start End
,Load
176 Full UDL 209 Live 2 Full UDL Dead 1
Pattern Location [ftl Magnitude Distribution Type Start End Load? No
No
MAXIMUM REACTIONS (I&) urd BEARING LENGTHS (in) : I I?. 6 - -
Dead 627 Live 528 627 528
1155 i Total 1 1155 ibearinq:
Bendinqf+l
0.40 - 11180 0.08 = L1953 Total Defl'n
0.20 = L1360 0.03 = <L/999 Live Defl'n fb1Fb. - 0.52 Fb* - 1300 fb ,. 678 0.14
0.19
u)UTlONAL DATA:
?ACTORS: F CD cw ct CL CF cv CfU Cr LC#
Fb'+= 1000 1.00 1.00 1.00 1.000 1.30 1.000 1.00 1.00 Fv' - 95 1.00 1.00 1.00
2
F-y'- 625 1.00 1.00 2
E - 1.7 million 1.00 1.00 2
Bending(+): LC# 2 - WL, M - 1732 lbs-ft Shear Deflection: LC# 2 - DtL EI- 188.95e06 lb-in2 : LC# 2 = WL, V = 1155, VBd - 922 lbs
Total Deflection - 1.50(Defln dead) + Defln Live. (Itdead L-live S-snow w&nd I-impact- C3constructionl (All LC's are listed in the Analysis output1
(CH - 1.0001 -
HSIGN NOTE&
!.~nvn~mbrbamgmanbrsrh.~be*hraly~.cmdrrptompov*br*of~~~~4.4.1. .Pbemwifytwthud.ca*ackdimnqpPpY.fayawg.
&a. 24, aDM 11:3%10 Bml
win check Cakulatbn sheet
.om. (b*P&~Pw
bad Type Distribution Magnitude Location fftl Pattern Start End 1 Dead Start End bad?
Full UDL
2 Live
209 No
fill UDL 176 No
UAWMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : m
n n
Dead 418
Live 352 , Total 770 Bearina:
"
41f
35; 77(
~~ ~~
SECTION VI. DESIGN CODE -1- ( .mrrrp~ h )
Criterion Analysis Value Desi n Value Analysis/Design Shear fv @d = 46 Fv? = 95 fVfFv' = 0.49
Bending(+) fb = 524 Fb' = 1300 Live Defl'n 0.01 = <L/999 0.13 = L/360
wm* = 0.40
Total Defl'n 0.03 - <L/999 0.27 - L/lBO 0.09 0.13
WDITIONAL DATA
WZCMS: F
Fb'+= 1000 1.00 1.00 1.00 1.000 1.30 1.000 1.00 1.00 CD CN Ct CL CF CV Cfu cr LC#
hl' = 95 1.00 1.00 1.00 2
F?'- 625 1.00 1.00 (CH = 1.000) 2
E = 1.7 million 1.00 1.00 2
-
Bending(+): LC# 2 - LHL, H - 770 Ibs-ft
Shear : LC# 2 = IYL, V - 770, V@d - 594 lba
Total *flection - 1.50(Defln-deadl + Defln-Live.
Deflection: LC# 2 - IYL EI- 82.49e06 lb-in2
(Wead L=live *snow W-wind I-impact 0-construction)
(All LC's are listed in the Analysis output)
3
2182ucamin0, Suite 103, Oceanside, CA 92054 Phone (7!30) 599-8568 Fax (780) 596-8838
9 4 /3
5
2182 El Camho Real, Suite 103, Oceanside, CA 92054 Phone (760) a@-8566 Fax (760) 598-8838
6
2182 fl Cemino Real, Suite 103,0ceanslde, CA 92
..
.
T-
,
0-+$-01
=j i
_. .. ii
m
I I
x x
* L
I
I
1 i
i
I
c. TITLE 24 REPORT
I
I
I
1 I
1
~ !
I
The Energpro computer program has authorized by the Califomis Energy Co
Title 24 Report for:
Valente Residence 2035 Alga Rd.
Carlsbad, Ca 92009
Project Designer:
Consolidated Construction Consultants
1020 S. Santa Fe Road
Vista. Ca
Report Prepared By:
Michael Dell
DELL CO.
1629 York Drive
Vista, CA 92084 (760) 940-0064
Job Number:
r12-13e
Date:
1 211 3/0 1
been used to perform the Calculations summarized in this compliance report. This program has approval and is 1 I
lmmission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards,
This program developed by Gabel DoddlEnergySofl, LLC (415) 883-5900.
~. EneWPrn ~~ 31B~EEe?x?oft"- ~~~ ~~~~ ~~~~ ~~~____~ ~ ~~~ ~~~~~~ ~ ~ ~~, Job Number: r12-13e -
UserNumber 1712 !
\ \ 0
$\ r
CJ
" I.