Loading...
HomeMy WebLinkAbout2035 CORTE DEL NOGAL; 150; CB910567; PermitStr *f BUILDING PERMIT 04/22/91 11 Page 1 ot Job Address Permit Type Parcel No Valuation Construction Type VN Occupancy Group B2 Class Code Description 1247 SF OFFICE SPACE IN SHELL 18 1 2035 CORTE DEL NOGAL COMMERCIAL TENANT IMPROVEMENT 25,564 Permit No Project No Development No L JL r A r f* OO S CB910567 A9100667 150 1994 04/22/91 0001 01 Appl/Ownr PLANT AND COOK 2385 CAMINO VIDA ROBLE CARLSBAD, CA 92009 Status Applied Apr/Issue Validated By 619-438-5191 326^.00 ISSUED 03/29/91 04/22/91 KZH OWNER CONTRACTOR MISSION WEST PROP WHITE CONSTRUCTION 7220 EL CAMINO REAL CARLSBAD, CA 92009 Fees Required *** Lie OWNER Lie C 452513 619-753-9272 Fees Collected & Credits A A- * Fees 1,432 00 Adjustments 00 Total Fees 1,432 00 Total Credi ts- Total Payments -Balance Due Fee description Building Permit Plan Check Strong Motion. Fee Enter 'Y' to Autocalc License Tax > f BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Building Sewer > Each Water Heater and/or Vent > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Three Phase Per AMP > * ELECTRICAL TOTAL ($10 Minimum) Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts > Each In^tall/Reloc Appliance Vent > * MECHANICAL TOTAL Units . Fe 2 00 -1 00 1 QC 100 00 1 00 1 00 e/Unit 2 50 6 50 2 50 50 9 00 4 50 168 1,264 00 00 00 Ext fee 259 168 4 895 1326 7 5 6 2 22 5 50 55 15 9 4 29 00 00 00 00 00 50 00 50 50 00 00 00 00 00 00 50 00 Data Y Y Y Y CITY OF CARLSBAD 2075 Las Palmas Dr, Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-iiRi PERMIT TYPE I 0TOMMERCIALfjNEW 0TENANT IMPROVEMENT D INDUSTRIAL DNEU QTENANT IMPROVEMENT D RESIDENTIAL QAPARTMENT DCONDO ^SINGLE FAMILY DUELLING Q ADDITION/ALTERAT ION DDUPLEX DEMOLITION DREL°CATION DMOBILE HOME DELE<;TI"CA|- DPLUMB!NG DMECHANICAL QPOOL DSPA QRETAINING WALL QSOLAR DOTHEB., PROJECT INFORMATION PLAN CHECK No 77 EST VAL_ PLAN CK DEPOSIT_ VALID BY DATE i 00C-FRKT FOR OFFICE USE ONLY ^ /&? 4JfAddress Nearest Cross Streets ling or Sui te No $" ItArt-) LEGAL DESCRIPTION CHECK BELOW IF SUBMITTED M2 Energy Calcs ASSESSOR'S PARCEL DESCRIPTION OF UORk , Lot No /<£> n? •7 A- Subdlvision -TYW* Structural Calcs 1 ^- J3Kf S~> Name/ Number D 2 Soi Is Report 1 &-jZ~l/» f* i U I Unit No 01 Addressed Envelope EXISTING USE Phase PROPOSED USE No BLDG SO FTG # OF STORIES CONTACT PERSON NAME CITY SIGNATURE STATE «><"<ESS ZIP CODE V I \^> f^ DAY TELEPHONE APPLICANT [J CONTRACTOR ] AGENT FOR CONTRACTOR ADDRESS STATE nOWNER DAGENT FOR OWNER DAY TELEPHONE 5 PROPERTY OWNER NAME iQ ADDRESS ZIP CODE*7"Z/' H~lCi 0TESSEE QTENANT /Z-<i> DAY TELEPHONE 6 CONTRACTOR NAME ADDRESS "" ^^ L0»&, ™ . , STATE LIC 0 Y^^S^ SIGNATURE ZIP CODE LICENSE CLASS TITLE DAY TELEPHONE CITY BUSINESS LIC DATE # DESIGNER NAME DAY TELEPHONE STATE LIC # WORKERS' COMPENSATION Workers' Compensation Declaration I hereby affirm that I have a certificate of consent to self insure issued by the Director of Industrial Relations or a certificate of Workers Compensation Insurance by an admitted insurer or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800 Lab C) INSURANCE COMPANY POLICY NO EXPIRATION DATE Certificate of Exemption 1 certify that in the performance of the work for which this permit is issued 1 shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION Owner Builder Declaration I hereby affirm that 1 aoi exempt from the Contractor s License Law for the following reason [~1 I as owner of the property or- my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law docs not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of complet on the owner builder will have the burden of proving that he did not build or improve for the purpose of sale ) \~] I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) Licensed pursuant to the Contractor s License Law) [~] I am exempt under Section Business and Professions Code for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9 commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substnnce Account Act? GYES DNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 Is the facility to be constructed within 1 000 feet of the outer boundary of a schoot site7 DYES CINO If ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS MET OR IS HEETIWG THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097( i ) Civil Code) LENDER'S NAME LENDER S ADDRESS 10 APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct I agree to comply with all City ordinances and State laws relating to building construction ! hereby authorize representatives of the City of Carlsbad to enter upon the above mornionsi-d property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINS1 ALL LIABILITIES JUDGMENTS COSTS AND EXPENSHS WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration Every permit issued by the Building Official under the provisions of this Code shall ex.nire by limitation anri become null and void if the building or work authorized by such permit is not commenced within 180 days trom the date of such Demit or it the build'ng o!~ work authorized by such permit is suspended or abandoned at any time after tne work is commenced for a period of 180 days (Section 303(d) uniform Building Code) PHONEQ OWNER [^CONTRACTOR _ /fr 2-7 f/ _ WHfFE File YELLOW Applicant PINK Finance APPROVED BY DATE PERMIT! CB910567 DESCRIPTION: 1247 CITY OF CARLSBAD INSPECTION REQUEST FOR 05/10/91 SF OFFICE SPACE IN SHELL TYPE CTI JOB ADDRESS: 2035 CORTE DEL NOGAL APPLICANT- PLANT AND COOK CONTRACTOR. WHITE CONSTRUCTION OWNER MISSION WEST PROP. REMARKS MH/TRAVIS/931-1130 SPECIAL INSTRUCT: PHONE: PHONE: PHONE: INSPECTOR AREA MC PLANCKf CB910567 OCC GRP CONSTR. TYPE VN STR:** FL:**** STE: 150 619-438-5191 619-753-9^72 INSPECTOR TOTAL TIME1 CD LVL DESCRIPTION 19 29 39 49 ACT COMMENTS ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical n/le LAS ***** INSPECTION HISTORY ***** DATE DESCRIPTION 050791 Frame/Steel/Bolting/Welding 050791 Rough Electric 050791 Rough/Ducts/Dampers 042691 Interior Lath/Drywall 042591 Interior Lath/Drywall 042391 Frame/Steel/Bolting/Welding 042391 Rough Electric ACT INSP COMMENTS AP MPC CEILING GRID SYSTEM AP MPC LIGHT FIXTURE CO MPC SEE INSP. COMMENTS AP MPC CO MPC SEE COMMENTS 4/25/91 PA MPC WALLS PA MPC WALLS CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB910567 FOR 05/07/91 DESCRIPTION. 1247 SF OFFICE SPACE IN SHELL TYPE- CTI JOB ADDRESS: 2035 CORTE DEL NOGAL APPLICANT: PLANT AND COOK CONTRACTOR: WHITE CONSTRUCTION OWNER: MISSION WEST PROP. REMARKS: MH/TRAVIS/753-9272 SPECIAL INSTRUCT. GRID PHONE: PHONE: PHONE: INSPECTOR AREA MC PLANCK* CB910567 OCC GRP CONSTR. TYPE VN STR:** FL:**** STE: 150 619-438-5191 619-753-9272 INSPECTOR / " TOTAL TIME: CD LVL DESCRIPTION 14 24 34 44 ACT COMMENTS ST Frame/Steel/Bolting/Welding PL Rough/Topout EL Rough Electric ME Rough/Ducts/Dampers ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP 042691 Interior Lath/Drywall AP MPC 042591 Interior Lath/Drywall CO MPC 042391 Frame/Steel/Bolting/Welding PA MPC 042391 Rough Electric PA MPC COMMENTS SEE COMMENTS 4/25/91 WALLS WALLS CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB910567 FOR 04/25/91 DESCRIPTION: 1247 SF OFFICE SPACE IN SHELL TYPE. CTI JOB ADDRESS: 2035 CORTE DEL NOGAL APPLICANT: PLANT AND COOK CONTRACTOR: WHITE CONSTRUCTION OWNER: MISSION WEST PROP. REMARKS: MH/TRAVIS/753-9272 SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION 17 ST Interior Lath/Drywall PHONE: PHONE: PHONE: INSPECTOR AREA MC PLANCKfl CB910567 OCC GRP CONSTR. TYPE VN STR:** FL:**** STE: 150 619-438-5191 619-753-9272 INSPECTOR ACT COMMENTS DATE DESCRIPTION ***** INSPECTION HISTORY ***** ACT INSP COMMENTS ESGIL, CORPORATION 9320 CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-I468 DATE 4/IS/91 / HT b t y^ i ; u <Jl\ J.QIJIU J. ±utN G C\ ["PLAN CHECKER T^FILE COPY PLAN CHECK NO *9 I ~ -5 (o~l SET J. PROJECT ADDRESS 2-Q^.S OcHre* "DeA O T T-PROJECT NAME O,QgC. 1. -L UPS 'DESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the 3urisdiction' s building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _ are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and snould be corrected and resubmitted for a complete recheck D The check list transmitted herewith is for your information The plans are being held at Esgil Corp. until corrected plans are submitted for recheck D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person The applicant's copy of the check list has been sent to- HI Esgil staff did not advise the applicant contact person that plan check has been completed [~1 Esgil staff did advise applicant that the plan check has been completed Person contacted Date contacted Telephone -_ REMARKS By UJUir f /vT. .- s ( Enclosures ESGIL CORPORATION GA AA LJRN "~JDM ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 56O-1468 DATE AM/9\» i JURISDICTION PLAN CHECK NO SET X PROJECT ADDRESS Q_C nPROJECT NAME OO£j i^^ (2,Q\ — \ C. T^)S,\ tOo^iCL c.. TI. _,PLAN QFILE COPYFjups ~DESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I—| The plans transmitted herewith will substantially comply I I with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ms The check list transmitted herewith is for your information. Es The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of tne check list is enclosed for the jurisdiction to return to the applicant contact person The applicant's copy of the check list has been sent to Cow-. RoHe^lQT (LoAitcA | Esgil staff did not advise the applicant contact person that plan check has been completed.-, 6.xcept by friavl II Esgil staff did advise applicant that the plan check has — been completed. Person contacted- 9 Date contacted: []] REMARKS: Telephone By; ESGIL CORPORATION 4.A; DGA DAA D RN QDM PLAN CORRECTION SHEET TENANT IMPROVEMENT PLAN CHECK NO •_ JURISDICTION- ID; :?:1009 PROJECT DATA OCCUPANCY BUILDING USE: TYPE OF CONSTRUCTION: ACTUAL AREA; \Q_A- / \ T. ALLOWABLE AREA: STORIES:_ HEIGHT: Q. SPRINKLERS: OCCUPANT LOAD: REMARKS: Date plans received by jurisdiction Date plans received by Esgil Corporation 4-A / 91 Date initial plan check completed 4/4/91 BVi i Applicant contact person FOREWORD. PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped The plan check is based on regulations enforced by the Building Inspection Department You may have other corrections based on la^s and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Code sections cited are based on the 1988 UBC The circled items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e . plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED LIST NO 58 TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC '^5-" I £X* / Submit plan showing location of all panels Submit panels schedules Submit electrical load calculations Indicate existing main service size Indicate existing total main service load Indicate new additional loads Indicate wiring method, i e EMT, metal flex Show exit signs on the electrical lighting plan(s) As per Section 3313 and 3314 of the 1988 UBC, provide two sources of pover to exit signs and exit illumination Provide receptacle(s) within 25' of the roof mounted A/C units UMC Section 509 Provide multiple switch lighting controls per Title 24, 2-5319 Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54 MECHANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of ^ 5 cubic feet jier minute of outsade air with a •fcotol e*r-culefeton-o£ — not-4ess— than 15 oMbac-feefc-per- •»inufee-pe*-oe«jeaftt- . Section 605 and 705, UBC X Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment Detail access equipment and working clearances to HVAC Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged Section 1205, UMC One-hour corridors shall not be used as an integral part of a duct system This includes the space above a dropped ceiling within the one-hour corridor UMC Section 706(b) PLOMBPiG Provide gas line plans and calculations, showing pipe lengths and gas demands UPC Section 1219 Provide drain, waste and vent plans Provide water line sizing calculations UPC Section 1009 Detail how floor drain trap seal is to be maintained UPC Section 707 (floor drain trap priming) Show P & T valve on water heater and 3etail drain line route from P & T valve to the exterior UPC Section 1007(e) Show 1/4" per 12" slope on drain lines UPC Section 407 and waste Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments) UBC Section 605 ENERGY Provide complete energy design calculations, including all existing design and new energy design for this building See attached non- residential energy design checklist For remodels in an existing conditioned space, show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards MISCELLANEOUS Please see additional that follow corrections or remarks To speed up the recheck process, note on this list (or a copy) whee each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list9 Please check Yes No CF-S 4/5/90 NOTE:The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall They are provided here as a courtesy to assist designers in developing the project documents All applicable provisions may not necessarily be included Please direct any questions regarding interpretations of these provisions to the local Fire Department Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction Section 3305(g)l Where exit signs are required by Section 3314(a), approved and listed internally, externally or self-illuminated low-level exit signs complying with Section 3314 shall be required The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door Such signs shall be of a type which is perceptible to the sense of touch Section 3314(e) Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level Sui_h marking shall be of a type which is perceptible to the sense of touch Section 3314(f) Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38 Section 505(e)6 EXCEPTION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection In educational occupancies, storage and janitor closets shall be of one-hour fire-resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating Section 802(c) -6 Section 1807 should be reviewed for all high- rise buildings The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than JOO If emergency warning systems are required, they shall activate a means of warning the hearing impaired Flashing visual warnings shall have a frequency of not more than 60 flashes per minute The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468, to perform the plan check for your project If you have any questions regarding these plan check items, please contact at Esgil Corporation Thank you Enclosures 1 1/8/90 Date ,4/4/91 Jurisdiction Gar U bad Prepared by«rm PLAN CHECK NO. VALUATION AND PLAN CHECK FEE Q Bldg. Dept. D Esgil BUILDING ADDRESS 5 Co\I VjQ.g '• == \£6 "^ VAAPPLICANT/CONTACT BUILDING OCCUPANCY £?"2x TYPE OF CONSTRUCTION V/'lO PHONE^O. DESIGNER PHONE CONTRACTOR PHONE BUILDING PORTION TX Air Conditionine Commercial Residential Res. or Comm. Fire Sprinklers Total Value BUILDING AREA \a4~7 VALUATION MULTIPLIER 2^),SO § @ § VALUE ^5S(^3 2.5Sk3> Building Permit Fee $ Plan Check Fee $ COMMENTS. SHEET OF 12/87 OPFiCE, BUILDING PLANCHECK ENGINEERING CHECKLIST ri S DATE:_8APRS PLANCHECK NO. 91- O5Ca"7 <ris T C H E K 2 N D C H E K 3 R D C H E K ZO35 CGRTF DF\ PROJECT ID: LEGAL REQUIREMENTS Site Plan MQSfli ^ ISO ITEM COMPLETE ITEM INCOMPLETE NEEDS YOUR ACTION ITEM SELECTED D 1. Provide a fully dimensioned site plan drawn to scale. Show north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimension setbacks. 2. Show on site plan. Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. 3 . Provide legal description and Assessors Parcel Number Discretionary Approval Compliance 4. No Discretionary approvals were required. 5 Project complies with all Engineering Conditions of Approval for Project No. _ Project does not comply with the following Engineering Conditions of Approval for Project No. _ N/Aan Date:Conditions complied with by: Field Review 7 Field review completed. No issues raised. 8 Field review completed. The following issues or discrepancies with the site plan were found' nnn A. nan B. ana Site lacks adequate public improvements Existing drainage improvements not shown or in conflict with site plan. C. Site is served by overhead power lines. P \DOCS\MISFORHS\FRM0010 DH REV 02/27/91 '—' '—' '—' D. Grading is required to access site, create pad or provide for ultimate street improvement. nan nan E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. F. Other: Dedication Requirements No dedication required. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8V x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: Dedication completed, Date By:. Improvement Requirements '—' '—' 11. No public improvements required. SPECIAL NOTE' Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy. I—II—1|—\i2. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: Improvement plans signed, Date: by.. P \DOCS\MISFORHS\FRM0010 DH REV 02/27/91 '—''—''—' 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date: By: DDE 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). 14. No grading required as determined by the information provided on the site plan. —' '—' 15 Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: by: Miscellaneous Permits 16. Right-of-Way Permit not required. 17. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: 18. Sewer Permit is not required. '—' '—' '—' 19. Sewer Permit is required. A sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. '—' '—' 20. Industrial Waste Permit is not required. P \DOCS\MISFORMS\FRM0010 DH REV 02/27/91 t nn 21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Building Permits. Permits must be issued prior to occupancy. Industrial Waster Permit accepted - Date . _ By : _ Fees Required 27. Park-in-Lieu Fee Quadrant: _ Fee per Unit: _ Total Fees: _ D Nl/ft 23. Traffic Impact Fee Fee Per Unit _ Total Fee: _ D M/$ 24. Bridqe and Thorough fare Fee Fee Per Unit: _ Total Fee: D ^/A 25. Public Facilities Fee required. D ^/^ 26 Facilities Management Fee Zone. Fee D N/$ 27. Sewer Fees Permit No. EDU's Benefit Area: Fee: D tyfy 28. Sewer Lateral Required: Fee: D 29. REMARKS: ENGINEERING AUTHORIZATION TO ISSUE PERMIT : SBY : _ DATE : P \DOCS\MISFORHS\FRM0010 DH REV 02/27/91 PLANNING CHECKLIST Plan Check No n ' 3&"7 Address x Planner t> &-> <* $ Phone 438-1161 ext (Name) APN 4) OJ <Uw w *-»Type of Project and Use r— » Zone Tr/1 _ Facilities Management Zone S -o -° Legend-° Sv * . . - T\ « <-> u ." W <U <U I /IL/J Item Complete (3 (Q fl] Q. Q. O. Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified D Environmental Review Required YES NO j/_ TYPE DATE OF COMPLETION % Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval D Discretionary Action Required YES NO APPROVAL/RESO NO DATE PROJECT NO OTHER RELATED CASES Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval D California Coastal Commission Permit Required YES NO DATE OF APPROVAL San Diego Coast Distnct, 1333 Camino Del Rio South, Suite 125, San Diego, CA 92108-3520 (619) 297-9740 Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval D D Landscape Plan Required YES NO See attached submittal requirements for landscape plans Site Plan Zoning 3 4 Provide a fully dimensioned site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, nght-of-way width and dimensioned setbacks Show on Site Plan Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and dnveway Provide legal descnption of property Provide assessor's parcel number Setbacks ODD i ana Front Int Side Street Side Rear /\/\ 2 Lot coverage l\f(\- 3 Height 4 Parking Additional Comments Required Required Required Required Required Required Spaces Required Guest Spaces Required Shown Shown Shown Shown Shown Shown ^ Shown Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER / Sdtfd /'^DATEz.^<?/ PLNCK FRM 2560 ORION WAY Citp of r OP i CARLSBAD, CA 92008 F/fl£ DEpARTM£NT PAGE °F TELEPHONE (619) 931 2121 DISAPPRQVEDcvPLAN CHECK REPORT APPROVED PLAN CHECK* PROJECT ^ Vb<- ARCHITECT ^° 6 OWNER t«'V->t.>t» OCCUPANCY ^- S SPRINKLERED '• J <•" ' & ' i€d.~ pi^f-v-M" W^VT paoPfJ/rrifS " x- CONST V-l° ^TENANT IMP ADDRESS >-"•»> ^«-'° ' ADDRESS 3-^S CAM,.O*> y,OA ADDRESS <"<s HlftK 8«. OIL < TOTAL SO FT \ ^l^ j^, fj o Vj- p» • — • aoewr PHONE lt 11 11'* PHONE V STORIES "*• / ^^ 'S*-^/?/ So-ll?5 ^ APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS PLANS, SPECIFICATIONS, AND PERMITS 1 Provide one copy of floor plan(s), site plan, sheets 2 Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project 3 Provide specifications for the following 4 Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, COs, alarms, hydrants) Plan must be approved by the fire department prior to installation 5 The business owner shall complete a building information letter and return it to the fire department FIRE PROTECTION SYSTEMS AND EQUIPMENT 6 The following fire protection systems are required . -fe , 0 Automatic fire sprinklers (Design Criteria &5 P61 M . f .r. Q, <_) ) D Dry Chemical, Halon, COz (Location ) D Stand Pipes (Type ) D Fire Alarm (Type/Location ) 7 Fi/e Extinguisher Requirements , \ B One 2A rated ABC extinguisher for each oQ^" sq ft or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel r fV1^1 An extinguisher with a minimum rating of *2-R 10 "£- to be located ^ " ' n Other 8 Additional fire hydrant(s) shall be provided EXITS _ 9 Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort .10 A sign stating, " This door to remain unlocked during business hours" shall be placed above the mam exit and doors G fti«-\CJ.11 EXIT signs (6" x 3A" letters) shall be placed over all required exilts and directional signs located as necessary to clearly indicate the location of exit doors GENERAL .12 Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code .13 Buildmg(s) not approved for high piled combustible stock Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids If high stock pil mg is to be done, comply with Uniform Fire Code, Article 81 .14 Additional Requirements 3-3?$" Ctmiv^o v/,Dft ,( CM .15 Comply with regulations on attached sheet(s) Plan Examiner | \ '-.xV^v^ I—s,/t.A^-^v-— Date- Report mailed to architect Metwith Attach to Plans 2560 ORION WAY CARLSBAD, CA 92008 TELEPHONE (619) 931 2121 PROJECT SP£C Smr& ISO ARCHITECT OWNER Cttp of ^ DEPARTMENT PAGE1 OF. PLAN CHECK REPORT APPROVED DISAPPROVED PLAN CHECK* ? (to F £ d-ll ADDRESS ADDRESS AnnRFSS 2-03S" Con-re D&C- -OCCUPANCY 1JL CONST TOTAL SO FT IV"0 STORIES Js , E SPRINKLERED 0 TENANT IMP APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS 9 10 11 12 13 PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of floor plan(s), site plan, sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project Provide specifications for the following _ Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, CO2, alarms, hydrants) Plan must be approved by the fire department prior to installation The business owner shall complete a building information letter and return it to the fire department FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required &. B Automatic fire sprinklers (Design Criteria ftS P£ C- P*? Pfo >6 ) D Dry Chemical, Halon, CO2 (Location ) D Stand Pipes (Type ) D Fire Alarm (Type/Location ) Fire Extinguisher Requirements B One 2A rated ABC extinguisher for each extinguisher not to exceed 75 feet of travel An extinguisher with a minimum rating of sq ft or portion thereof with a travel distance to the nearest iQ&Mo be located 0£flCg D Other 8 Additional fire hydrant(s) shall be provided EXITS Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort A sign stating, " This door to remain unlocked during business hours" shall be placed above the mam exit^md doors EXIT signs (6" x 3/4" letters) shall be placed over all required exilts and directional signs located as necessary to clearly indicate the location of exit doors GENERAL Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code Buildmg(s) not approved for high piled combustible stock Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids If high stock pil ing is to be done, comply with Uniform Fire Code, Article 81 .14 Additional Requirements .15 Comply with regulations on attached sheet(s) & 9i**SAW* ---Plan Examiner Date In Iill Report mailed to architect Met with Attach to Plans COMMERCIAL/INDUSTRIAL APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT CITY OF CARLSBAD APPLICATION: NEW ^ BUILDING P.C. NO. (CHECK ONE) REVISED APPLICATION NO.: INDUSTRIAL CLASS: BY. C^tA^-ftv^ L //JC-Oo-o-'v. DATE: 2 Signature of City Representative APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT A. GENERAL: SITE APPLICANT; ^f/^^^t/ U/ft/t^T~ P&&P ADDRESS:_ TYPE OF BUSINESS; ^F^U^. ^ APPLICANT'S ADDRESS; 12*r*?<r Hid H &<-vFF 1P&. *I1<3 <5J5crrO /v) B. WASTES AND PROCESSING: (Check where applicable) \2\ Domestic Waste Only |~| Industrial Waste |~| Industrial Waste NOT ^f Discharged to Sewer Discharged to Sewer ^ GENERAL DESCRIPTION OF WASTE (Chemical and Physical Characteristics of proposed waste): GENERAL DESCRIPTION OF PROCESS (If Applicable): C. WASTES TO BE DISCHARGED TO SEWER: WASTE: TREATED: QUANTITY: AVERAGE GPD (Check One) UNTREATED;(Daily) MAXIMUM " GPD (Gallons Per Day) APPLICANT OR REPRESENTATIVE OF FIRM; /^^xf^\^Q _ __ (Print) TITLE: SIGNATURE: x^W^W /M/UT*/ ^ DATE: •* * .' Lighting Summary'and Worksheet (paiti of 2)CF-5 Mnt Agency U» Cn*y Proposed Adju ,ted LPO BuJckoj W«n».CF-5) 2 CortralC.-aettWBttnWS.S8) 3 Acfu**»dW«n*<Lin« I -Un»2) •1 Condborwd Boar Ar» « S 12 - / V6 Tajlored LPD Approsdl (when-applicable) Z ToxKWsoitorlC 3 NovTxrii W«tt» har 1C £ * P (W3-5O) x _Ta«x W«ta har 1C: G. H * l'(WS-5E) . S Ncr>-TaiX W«tt» for 1C G, H * I (W3-Sc) T Toot AOoMWd Worn (In** 1-5) 3 Cooanoo»d Poof Ar»«r{" *' ~* 9 W«nmuni UPOfUv* 7/Ca>»B1 i"1* *"\- Whole Building LPD Luminaire Schedule W«a ^"'' "»' W«a W«H» 11 W«c» ' 1: 'I'Wam Woox <Vooz 12 WnamZ ., •• is-- l-W Lunrtmra Pa^9f9nst„ Cod*joourrvtnts Wcospor Totai Wars' 'I HAZARDOUS MATERIALS QUESTIONNAIRE Business Name Contact Person Telephone Mailing Address Plan File * Plan File #Mailing Address City State PART I. FIRE DEPARTMENT • HAZARDOUS MATERIALS MANAGEMENT DIVISION. OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use process or store any of the following hazardous materials If any of the items are checked off applicant must con;act the Fire Department-Hazardous Matenals Management Division 525 B Street Suite 705 San Diego CA 92101 Telephone (619) 533-4400 prior to plan subrnlttal 5 Organic Peroxides 10 Cryogenics 6 Oxidizers 11 7 Pyrophoncs 8 Unstable (Reactive) Matenals 9 Water-Reacbves 1 Explosive or Blasting Agents 2 Compressed Gases 3 Flammable or Combustible Liquids 4 Flammable Solids Highly Toxic or Toxic Matenals 12 Radioacoves 13 Corrosives 14 Other Health Hazards HAZARDOUS MATERIALS MANAGEMENT DIVISION.PART II. COUNTY OF SAN DIEGO HEALTH DEPARTMENT CONTINGENCY PLAN REVIEW If the answer to any of the questions is yes applicant must contact the County of San Diego Hazardous Matenals Management Division 1255 Imperial Avenue 3rd floor San Diego CA 92138 Telephone (619) 338-2222 prior to the Issuance of a building permit YES NO (FEE MAY BE REQUIRED) Is your business iype listed on the reverse side of this form'' Will your business dispose of Hazardous Substances or Medical Wastes in any amount'' Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons 500 pounds or 200 cubic feet of compressed gas? Will your business use an existing or install an underground storage tank? Will your business store, use or handle carcinogens reproductive toxins or Acutely Hazardous Matenals? Will your business be located within 1 000 feet from the outer boundary of a school and handle Acutely Hazardous Matenals? PART III. SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes applicant must contact the Air Pollution Control District 9150 Chesapeake Dnve San Diego CA 92123 Telephone (619) 694-3307 prior to the Issuance of a building permit YES NO 1 I I I >^l Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution Control Distnct Permit Categones on the reverse siiJe of this form'' 2 dl C2j (ANSWER ONL> IF THE ANSWER TO QUESTION 11S YES ) Will the subject facility be located within 1 000 feet of the outer boundary of a school (K thru 12) as listed in the current Directory of School and Community College Districts published by the San Diego County Office of Education and the current California Pnvate School Directory compiled in accordance with provisions of Education Code Section 33190' Briefly describe nature of the intended business activity Name of Owner or Authorized Agent estolSignature of Owner or Authorized Agent I declare under penalty of perjury that to the best of my knowledge and belief the responses made herein are true and correct ^7 " ,/ /t ^1' /f' Sy /> *~/eZ^i^ts'L^/ \ s//t/l/t>^/ *•- — Oate ^_ DO NOT WRITE BELOW THIS LINE FIRE DEPARTMENT OCCUPANCY CLASSIFICATION. BY Date EXEMPT FROM PERMIT REQUIREMENTS COUNTY HMMD APCD APPROVED FOR BUILDING PERMT BUT NOT FOR OCCUPANCY COUNTY HMMD APCD APPROVED FOR OCCUPANCY COUNTY HMMD APCD APCO (10-90) Certificate of Compliance (Pan 10(2)Performance Requirements Ot -1 B -SLI 'TtliL> ___ A73 iiiocl/IT rKjm Dam brCmtificjim LOC.HIOII City/Town COX MCCIiANICAU,_INC (G19) 27.1-7100.oLuniunlition Aiiilini/firm Tolcnltono for fnlwcomont Arjoncy Ur.o Cvily O'uiUGriiJ PorrinrWurnoTr PF.ui CliockodHy Approved Fly DilZ Prlnrlpnl D«iiln,nnr Tho propound hilildim) will tvi in 'iili'Innlnl nwnpli uf<\ wilii Hid C ililnnn i llmldinn, 1 nnnjy 1 llmonry I mcl net provKtiKl it r liuili irrtmliruj ID llio (il mr nnd -sou. ilir >tioi\'> uncl prnvidiMl Kilum impfovommif urn cromploiod 'ArrorcUcuj lo tlm rtKyuriummt in<lv.ntncl on (Ins Coiulicnio nl Complnnco llio plnns -iivl pu< ilintmn h ivt> IMMHI pcnn-Miiil in mrluito \|| --i<ifiilinnl <munjy ron'iiivxlmn In Hiiro-' lOffiiMid tni rnniphnnr«> with tho tnndTffl Uotldm() mori* \\\'\\ nrn i)ncoo(litx>n(v<l nniVt^r not .*t>l>]i>rl lo Ihf) st'inrUinlr i\rn tniliriitfxt nn thn 1 norny Annlynl Iho onfrrjy portnrnnnro inilyi' mnnnnriNl i« low w is porlomiod ti inr] nn tpprnvi rl Cl O nlmliiion 1111 tluvl with ( 1 i^ i[>r>ri>v<Kt hxod nnd mr.lnni <l ( IKJIIWIMIIIVJ input' Inr Dm ipplir il 1. rlim in 7 OMO nod <x-<-upinc> lyivi -in<l tinruj in ipprnpn in n pri i MI inon nl huildini) roniny nnd piw-inl ronli'jorilion All 'ifjnilir.Tnl i noiQy conr.oryTfVon lo ilun i nio lisli-<l hnlow or on in nil irlii n iipplmnrnt plnns ^ ^.7 ^'ftcrrbfrfu.,,,>Jrifu Comply Adci^i "£/<? ^: tf } t Cpiic (LituJ f^ ^ Z-7 -^/ £T tt PtAtytfT '*" Ptr^T'OOOICINi v&fraad, GH 920C9 5£ &ftl C]^^ TulupKoou Gtil Liudiiio No Owner Tho onorny rnn^nrvntion loitures nnd porforrmnro spocilinniions mdicnii cl on thr doriimnnl nnd on tho pl'ins nnd spociliciinons slnll npply lo luturo nllorilions unit's conipliinno r rtenionslrntod nnow md n m w CoMilicito of Cornpli moo 11 MjhmilK d A copy ol this Or rtilicjiln will Ix rr-lninf d ind Irirnmiilrd in IIIIUKI tomnl' suli'eqiii "i ownni or oilu r with lO'pnnMhilily lor in ikinrj unprovi monf or moililicntinns lo tho Imililimj II llu r< itilir \to I' lo t T new C( idlicito imy no K.qiiKdd luiloio a f* Mini ir. I'.siuid lor -\lior >tioi« UncomlmoniM) TH 'ii am iiMliCTHsl on llio pHni ind it Iho-o Trin' ntn condilinnod in Ihn luuiio thny niusl ho undo 10 comply wilh Iho npplirahlo onorgy snndirds Dicn in ollccl Ntjitio/Titlu Company Al!dlUS!> 1 Dun 1 £L- OL/fe-^f .^t/ Hs&fiyT P&tff* T (S?<2-H r^UJPF }2rt. *• 11-0 r?/c^£? SM «?2/-2.i r.nlnrrcTnrnl Aprnry Tho propo'od liuildmr) nnd lultirn illnntion' will comply wilh iho Cnlilnrnin nuddinq 1 nnrfjy 1 Itinonry . 1 indnrd*1 [irovulorl liiiuHi nlh ntino* nusjl itio ri qinrornoril indi^Tldfl on this UnMihc ltd -iotl nil npplic ihld mnrul iiory mrriMirus '!•"» long is tho building occuji'inry Iyp« icrmuns unclnngfKi oiijn iluru N ,nio/r,i]t A(jLi\cy Aiiiio^i Dalo City/Sl.it(i/7ip r'#x$-'d^ / fp^sip&S'f 'li'AYtl'fix MECHANICAL, INC Cl°oS2by SCRIP PS RANCH Rl VD , SUTTf C AdcIroiS SAN DICGO, CA 92131City/Guio/Zip(619) 271-7100 Tulopliono feLpU ^.Hlgl-U C?/XT^. GofiefBl ' ftolcrcnco 1 Uncondilionod or Muln lonnnt shell'' | 1 CfC Occtipnncy Typo ^ - 1 L-PC? 3 UnC Occ Group/Division 1 1^-2. A Clinmto 7ono 7 r» Conditionod floor Arm 'Z&L?^' '' r, Unconditioned floor Arcn "^/ 0_ „ 1 7 nurlget Tnhln (Ir Clnndnrd') JffJ^l. 7.'^*P" (1 All fnnrrjy Oudgol (V;" 1A) I^^'JA ^ ° k(Mu/ 1 yi 0 CnlcMnlhodCrCCodo/Dntf TP^fc C^O-t- 10 Wiiltiptmr 4^ _ & °\t> 1 1 Cnlculitntl Tnntgy Use ?UtfyT ^ ^ l»ni\i/sl yr Cnvolopo riorjiilromonta 1** Avornrjo nool/Cpiliryj fli ^U1PU)T" 11 '1 h f sl/Dlu 13 Avorngo Hxtotior floor R| I WA1 l» f 'l/Otu 1 1 Avornrjn Opiqno Wilt D| ^ 4"] h f M/niu 15 Glnunn Aroa In Will (fi^'T' 1 1C Avornno SC (Wnll nln?ino) ^^7 17 Claiing Aron in ffool ^ 'I ^ 10 Avnrnno SC (Roof nliTinol ~*f M^* ,^. Llohllnn noqiilromonts \ ^ 11 Allowod Whnlo niiildinn. \ PD gt/Tp\4T jjT w-w/t N^ ?f> Allowod Common Arcis LPD H^ WTIC^ 1 ^v 21 Allowod Tomnt flpnro LPO 1 wntl'/ 1 ^ ?0 Packngo Lighting floduction 1 wniiVsl V^l ?n Lighting Control'; norjuired'' ^ f_ _ v^ (V/N) Moolmnlcn! neqiilromont* ">4 Syitom Typo U^fH5fz-idf'P*& trT rU^Jf* 25 Unit fan Power !?£Ll4L_ !!!_ wnus/clnv- "0 Hnlrxt Cooling CdtciRnry _ |o ^ ^f2- (unitr) 07 ftalwl Coolinr) Capncily . ^ (unil'J 00 flnlixl 1 lonling fllicienry __ _ l1~ C0^ (umtr) 00 flnlnd Homing Cnpncity ^ _^f_ _ (units) HO Cconomlror cooling "> M ta_ (Y/N) 01 Cf IXAttnchrxt' . V (Y/N) fCM form nevi-erf Coplr-mhnr 1000 ^A G?L&/f- f fige nl