HomeMy WebLinkAbout2038 CORTE DEL NOGAL; 100; CB044651; Permit1-2005 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No CB044651 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title ilicant 2038 CORTE DEL NOGAL CBAD St 100 Tl Sub Type 2130613000 Lot# $178,59100 Construction Type Reference # 5761 SF TENANT IMPROVEMENT .SJHELL TO OFFICE \ COMM 0 NEW PMPETETIVE EDGE CONSTRUCTJPN^ 30 CENTENNIAL WY Status ISSUED Applied 12/23/2004 Entered By KG Plan Approved 02/25/2005 Issued 02/25/2005 Inspect Area RB Plan Check* Owner CARLSBAD CORPORATE CENTER L P C/O RICHARD BOURSTON 5500 TRABUCORD #100 IRVINE CA 92620 760 480-2675 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $789 88 Meter Size $0 00 Add'l Reel Water Con Fee $51342 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $37 50 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $6000 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $3,250 36 $000 $000 $000 $2,236 00 $000 $209 00 $11000 $7050 $000 $2,11560 $000 $000 $9,392 26 Total Fees $9,392 26 Total Payments To Date $9,332 26 Balance Due.$60.00 BUILDING PLANS IN STORAGE ATTACHED 3573 03/11/05 0002 01 02 CGP 60 »00 Jnspector FINAL APROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees tn connection with this protect NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave, Carlsbad CA 92008 FOR OFFICE USE ONL PLAN CHECK NO EST VAL PlanCk Deposit Validated By Assessor's Parcel #Existing Use Proposed Use Addrefe4indude BkJg/Suite #) Legal Description , - r ~ <7_J 4-, £>tf L - C-b " O1 . ' Business Name (at this address) ~-v Lot No Subdivision Name/Number Unit No Phase No Total # of units Description of Work SO" FT # of Stones # of Bedrooms # of Bsthrooms (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name A^ State License # \\fl" \f Designer Name State License # Address -^ U0V License Class B7 Address City City State/Zip City Business License # \L? State/Zip Telepl 051.0 ioni# >l Telephone # Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is Issued D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance earner and policy number are -l/slD .x, . i Insurance Company <flfa UWWtoUfH Vl& f^'p^cvNo 0*fl/ 008^7 g>4- Exo.ratk.n Date J AT^ . 0*5 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and cMI fines up to one hundred thousand dollars($100,000), In addition to tff\°* of condensation,damagajjn-provlded for In Section 3706 of the Labor Code, Interest and attorney's fees. SIGNATURE /J^^-f^^ DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason Q I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure Is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement D YES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) S /} / 4. PROPERTY OWNER SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave, Carlsbad CA 92008 Page 2 of 2 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or nsk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES j< NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code) LENDER'S NAME LENDER'S ADDRESS. I certify that I have read the application and state that the above information Is connect and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA. An OSHA permit is required for excavations rtC'O" deep and demolition or construction of structures over 3 stories in height. EXPIRATION Every permit issued by the by such permit is not commenced within 180 the work is commenced for a period of 180 APPLICANT'S SIGNATURE under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after 106 4 4 Uniform Building Code) DATE WHITE File YELLOW Applicant PINK Finance CltyifGirtsbad Final Building Inspection Dept: Building Engineering Plan Check # Permit # Project Name Address Contact Person Sewer Dist. Inspected/^" Bv (x£ Inspected By Inspected By Planning CMWD St CB044651 5761 SF TENANT IMPROVEMENT SHELL TO OFFICE 2038 CORTE DEL NOGAL #100 KELLEY CA 7 / Phone 7604970781 or 87 Water Dist CA Date ) I Inspected T/Z-£w9l5— Date Inspected Date Inspected Lite %re Date Permit Type Sub Type Lot 0 Approved V^ Approved Approved 04/25/2005 Tl COMM Disapproved Disapproved Disapproved Comments Inspection List Permit* CB044651 Type Date Inspection Item 05/20/2005 89 04/27/2005 89 04/26/2005 34 04/26/2005 39 04/25/2005 19 04/25/2005 29 04/25/2005 34 04/25/2005 39 04/25/2005 49 04/22/2005 34 Final Combo Final Combo Rough Electric Final Electrical Final Structural Final Plumbing Rough Electric Final Electrical Final Mechanical Rough Electric Tl COMM Inspector Act TP RB RB RB RB RB TP RB RB TP AP PA AP AP NR NR PA CO CO PA 5761 SF TENANT IMPROVEMENT SHELL TO OFFICE Comments TEMP C OF O - SEE NOTICE ATTCH EMR NEW PULL & MTR SECT - RE- CONNECT H P - NEED TO ATTCH UFFER TO EXT OF PULL SECT AND ATTCH TOGRN BUSSING FOR METER RELEASE - SEE NOTICE NEW MSB & MTR SECT REL FLR 04/08/2005 84 Rough Combo 04/07/2005 14 Frame/Steel/Bolting/Weldm RB 04/07/2005 24 04/07/2005 34 04/07/2005 44 04/05/2005 14 04/05/2005 34 04/05/2005 44 03/16/2005 17 03/11/2005 14 03/11/2005 24 03/11/2005 34 03/07/2005 14 03/07/2005 24 03/07/2005 34 02/28/2005 14 02/28/2005 21 02/28/2005 34 Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Weldm Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Frame/Steel/Bolting/Weldm Underground/Under Floor Rough Electric RB RB TP PY RB RB RB RB RB RB RB PC PC PC PC RB RB RB RB RB RB CO CO PA AP PA PA PA PA CO AP CO AP PA AP CA CO NR AP NR AP NR POWER RE-SET COMPRESSION STRUTS PER RON B ON 4/7 OK ON T-BAR EXCEPT RM 103 - SEE NOTICE ATTCH ON T-BAR SEE NOTICE ATTACHED WALLS OK TO SUPPLY INSUL CERT ALREADY SIGNED OFF & NR - SEE NOTICE ATTACHED see notice attch Monday, May 23, 2005 Page 1 of 1 DATE PERMIT # JOB ADDRESS DESCRIPTION. CODE DESCRIPTION ^^ INSPECTOR PLAN CHECK,# ACT Af> COMMENTS City of Carlsbad Bldg Inspection Request For 04/27/2005 Permit* CB044651 Title 5761 SF TENANT IMPROVEMENT Description SHELL TO OFFICE Inspector Assignment RB 2038 CORTE DEL NOGAL 100 Lot 0 Type Tl Sub Type COMM Job Address Suite Location OWNER CARLSBAD CORPORATE CENTER L P Owner CT CAPITAL VENTURE PARTNERS I LTD Remarks Phone 7604970781 or 87 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By DAVID Entered By CHRISTINE Act Comment Associated PCRs/CVs Inspection History Date Description 04/25/2005 19 Final Structural 04/25/2005 29 Final Plumbing 04/25/2005 34 Rough Electric 04/25/2005 39 Final Electrical 04/25/2005 49 Final Mechanical 04/22/2005 34 Rough Electric 04/08/2005 84 Rough Combo 04/07/2005 14 Frame/Steel/Bolting/Welding 04/07/2005 24 Rough/Topout 04/07/2005 34 Rough Electric 04/07/2005 44 Rough/Ducts/Dampers 04/05/2005 14 Frame/Steel/Boltmg/Welding 04/05/2005 34 Rough Electric 04/05/2005 44 Rough/Ducts/Dampers 03/16/2005 17 Interior Lath/Drywall Act NR NR PA CO CO PA AP PA PA PA PA CO AP CO AP Insp RB RB TP RB RB TP PY RB RB RB RB RB RB RB PC Comments NEW PULL & MTR SECT - RE-CONNECT H P - NEED TO ATTCH UFFER TO EXT OF PULL SECT AND ATTCH TO GRN BUSSING FOR METER RELEASE - SEE NOTICE NEW MSB & MTR SECT REL FLR POWER RE-SET COMPRESSION STRUTS PER RON B ON 4/7 OK ON T-BAR EXCEPT RM 103 - SEE NOTICE ATTCH ON T-BAR SEE NOTICE ATTACHED CITY OF CARLSBAD BUILDING DEPARTMENT NOTICE (760) 602-2700 1635 FARADAY AVENUE DATE **' *- 7 'TIME LOCATION PERMIT NO FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? i , YES FOR FURTHER INFORMATION, CONTACT PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 04/25/2005 Permit* CB044651 Title 5761 SF TENANT IMPROVEMENT Description SHELL TO OFFICE Inspector Assignment RB Type Tl Sub Type COMM Job Address 2038 CORTE DEL NOGAL Suite 100 Lot 0 Location OWNER CARLSBAD CORPORATE CENTER L P Owner CT CAPITAL VENTURE PARTNERS I LTD Remarks Phone 7604970781or 87 Inspector Total Time Requested By KELLEY Entered By JANEAN CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Associated PCRs/CVs Date 04/08/2005 04/07/2005 04/07/2005 04/07/2005 04/07/2005 04/05/2005 04/05/2005 04/05/2005 03/16/2005 03/11/2005 03/11/2005 03/11/2005 03/07/2005 03/07/2005 03/07/2005 02/28/2005 Inspection History Description 84 14 24 34 44 14 34 44 17 14 24 34 14 24 34 14 Rough Combo Frame/Steel/Boitmg/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Frame/Steel/Bolting/Welding Act AP PA PA PA PA CO AP CO AP PA AP CA CO NR AP NR Insp PY RB RB RB RB RB RB RB PC PC PC PC RB RB RB RB Comments COMPRESSION STRUTS PER RON B ON 4/7 OK ON T-BAR EXCEPT RM 103 - SEE NOTICE ATTCH ON T-BAR SEE NOTICE ATTACHED WALLS OK TO SUPPLY INSUL CERT ALREADY SIGNED OFF & NR - SEE NOTICE ATTACHED see notice attch CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME. LOCATION ~ 3?^r PERMIT NO / /t FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? ! : YES FOR FURTHER INFORMATION, CONTACT ft PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 04/26/2005 Permit* CB044651 Title 5761 SF TENANT IMPROVEMENT Description SHELL TO OFFICE Inspector Assignment RB 2038 CORTE DEL NOGAL 100 Lot 0 Type Tl Sub Type COMM Job Address Suite Location OWNER CARLSBAD CORPORATE CENTER L P Owner CT CAPITAL VENTURE PARTNERS I LTD Remarks Phone 7604970787 Inspector Total Time CD Description 34 Rough Electric Requested By KELLY Entered By CHRISTINE Act Comment Associated PCRs/CVs Inspection History Date 04/22/2005 04/08/2005 04/07/2005 04/07/2005 04/07/2005 04/07/2005 04/05/2005 04/05/2005 04/05/2005 03/16/2005 03/11/2005 03/11/2005 03/11/2005 03/07/2005 03/07/2005 03/07/2005 02/28/2005 02/28/2005 02/28/2005 Description 34 84 14 24 34 44 14 34 44 17 14 24 34 14 24 34 14 21 34 Rough Electric Rough Combo Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Boltmg/Welding Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Frame/Steel/Bolting/Welding Underground/Under Floor Rough Electric Act PA AP PA PA PA PA CO AP CO AP PA AP CA CO NR AP NR AP NR Insp TP PY RB RB RB RB RB RB RB PC PC PC PC RB RB RB RB RB RB Comments NEW MSB & MTR SECT REL FLR POWER RE-SET COMPRESSION STRUTS PER RON B ON 4/7 OK ON T-BAR EXCEPT RM 103 - SEE NOTICE ATTCH ON T-BAR SEE NOTICE ATTACHED WALLS OK TO SUPPLY INSUL CERT ALREADY SIGNED OFF & NR - SEE NOTICE ATTACHED see notice attch sa^= i- — — . ^= EsGil Corporation /n Partners Kip vntH government for <Butftfmg Safety DATE 2/23/O5 Q APPLICANTa ^ORls^ JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO. 04-4651 SET III PROJECT ADDRESS 2038 Corte Del Nogal Suite 100 PROJECT NAME Hunter Chase - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes [X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to EXl Esgil Corporation staff did not advise the applicant that the plan check has been completed I I Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax #. Mail Telephone Fax In Person [X] REMARKS- Applicant to revise note on sheet E-5 to city held sets By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 2/15/05 tmsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 EsGii Corporation In (Partnership wttK government for QuiCding Safety DATE- 2/2/05 Q APPLICANT JURISDICTION City of Carlsbad Q FTOTREVIEWER Q FILE PLAN CHECK NO 04-4651 SET II PROJECT ADDRESS 2O38 Corte Del Nogal Suite 1OO PROJECT NAME Hunter Chase - TI [~1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck [~1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person C*y The applicant's copy of the check list has been sent to McArdle Associates 5838 Edison Place Suite 100, Carlsbad, CA 92008 LJ Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted Autumn Ferrante Telephone # 760-431-7775x109 Date contacted <l/2./o5 (by f^ay) Fax # 760-431-7585 Mail —Telephone Fax ^ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 1/25/05 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O4-4651 2/2/05 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO 04-4651 PROJECT ADDRESS 2038 Corte Del Nogal Suite 100 SET. II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 1/25/05 2/2/05 REVIEWED BY. Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plen review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec. 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to ESGIL CORPORATION. B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes aNo City of Carlsbad O4-4651 2/2/05 Please make all corrections on the ongmal tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engmeenng and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code The electrical sheets must be signed. 2 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 752# rooftop air handler units Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code The copy of the shell design show the roof to be designed for 700# and the new equipment is shown as 752# please provide calculations to show the roof adequate to support the new equipment. 4 Please have the document author and the pnnciple designer of the LTG-1 form sign the imprinted document Documents are not signed. 5 Please clarify the electrical single line diagram Show the AIC rating of sub- service equipment and the transformer grounding conductor and grounding location Please revise the single line to show the grounding conductor an location for the new 150 KVA transformer. 9 Show that at least one water closet fixture, located in a compartment, shall provide the following, per Section 1115B 7 1 3 Please dimension the enlarged restroom detail to show the disabled stall to be 60" wide. a) The stall shall be a minimum of 60" wide City of Carlsbad O4-4651 2/2/O5 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGil Corporation In Partnership with government for <Suifding Safety DATE 1/1O/O5 D APPLICANT g^"TT JURIS. ^> JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO • O4-4651 SET I PROJECT ADDRESS- 2038 Corte Del Nogal Suite 1OO PROJECT NAME Hunter Chase - XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to McArdle Associates 5838 Edison Place Suite 100, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Autumn Ferrante Telephone # 760-431-7775 Date contacted ill(/0$ (by ^) Fax #•/ I ^ J Mail --^Telephone -^'Fax-'^ln Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 12/28/04 tmsmUdot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576 City of Carlsbad O4-4651 1/10/05 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O4-4651 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 12/23/04 DATE INITIAL PLAN REVIEW COMPLETED 1/10/05 JURISDICTION City of Carlsbad USE Office ACTUAL AREA 576 Isf STORIES 1 HEIGHT OCCUPANT LOAD 43 DATE PLANS RECEIVED BY ESGIL CORPORATION 12/28/04 PLAN REVIEWER" Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O4-4651 1/10/O5 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 752# rooftop air handler units Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code 3 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 4. Please have the document author and the principle designer of the LTG-1 form sign the imprinted document 5 Please clarify the electrical single line diagram Show the AIC rating of sub- service equipment and the transformer grounding conductor and grounding location 6 Please clarify the notes for the single line diagram in the printing process they were printed unreadable 7 Please provide the complete MECH documentation Provide all MECH-4 documents and explain why on the only MECH-4 provided the installed equipment exceeds the allowable? City of Carlsbad O4-4651 1/10/05 8 Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 9 Show that at least one water closet fixture, located in a compartment, shall provide the following, per Section 1115B 7.1 3' a) The stall shall be a minimum of 60" wide 10 If showers are proposed, show or note compliance with the following requirements, per Section 1115B62. a) Compartments are either. i) 42" in width between wall surfaces, and 48" minimum in depth (having an entrance opening > 42"), or, n) >60" in width between wall surfaces, and 30" minimum in depth (having a full opening width on the long side). As an alternate, showers 60" minimum in width may be 36" minimum in depth as long as the entrance opening width is a minimum of 36 inches. b) Grab bars comply with Section 1115B 8 located i) On walls adjacent to and opposite the seat u) Mounted >33" but =36" above the shower floor c) If a threshold or recessed drop is used, it shall be i) 4F in height ii) Be beveled or sloped ^5° from the horizontal. d) Indicate a folding seat, located on the wall adiacent to the controls, 18" above the floor e) The soapdish shall be located on the control wall ^0" above the shower floor f) If a separate shower compartment is not provided, the shower is be: i) Located in a corner, with L-shaped grab bars extending along two adjacent walls n) A folding seat adjacent to the shower controls is to be provided. g) A flexible hand-held shower unit is required with' i) A hose >60" long n) Head mounted 48" above finished floor NOTE- Two wall-mounted heads may be installed in lieu of the hand-held unit in areas subject to excessive vandalism 11 Please revise the plans to show restroom 104 and 114 to be fully accessible or clearly note on the plans restroom 104 and 114 are for the personal and private City of Carlsbad O4-4651 1/10/O5 use of the business owners only and not to be used by employee's or customers and indicate office 104 and 114 to be the private offices of the business owners To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction Please indicate Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you CITY OF CARLSBAD POLICIES AND PROCEDURE 'JUMBER: 80-6 SUBJECT: ROOF MOUNTED EQUIPMENT EFFECTIVE: 5/1/92 SECTION BUILDING DEPARTMENT SUPERSEDES:SQ.6I9/10/SO) 80-6(5/01/81) PURPOSE: INTENT: POLICY: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT PENETRATIONS ON1 COMMERCIAL AND INDUSTRIAL BUILDINGS. A B. C. 1 . 2. 3. Maintain roof Integrity. Prevent hazardous condition to firemen who must figh; fira on the roof. Provide an installation that is eesthstically sensitive to the building end adjoining properties/ - * » All equipment shall ba concealed from view end the design * shall meet approval of the Planning Department. AH equipmsn; shall be specifically designed and approved for exterior usa end shall ba approved by tha City of Carlsbad Building Departmsnt. All roof mounted equipmen; shall be on E platform vyhich shall be sn integrel pan of the rooMlashad ana waterproofed. Whsn a screen Is spproveo, ir shall have as few roof connections zs possible and be structurally adequate. All electrical, plumbing, mechanical ouct Work ana related piping shall ba inside ihe building and not on the roof. AH connections related to equipmant shall be ' made In ths sama roof opening on Tha platform or have the prior Epproval from the building official. Sewer verus shall be brought to one main vent below the roof ana' hsve ons penetration where restrooms or other plumbing fixtures are back to bsck or in the general proximity Air exhaust fans and other equipment shall be within the building end uss the same roof opening where restrooms and other equipment are back to back or In general proximity. Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from The building official. Where new equipment is Installed, unused'or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, ^r\d other Delated ' appurtenances shall be removed from roof and Unused ripenings p.roperly seaiea -to maintain roof Integrity. " . •The architect should, through design, conceal tha heating/AC unit end other, equipment whether they are pn the roof or elsewhere. 5. 8. 7. initiated By:Approved TT C »./•«• T », i iff TOTflL P. City of Carlsbad O4-4651 1/1O/O5 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 04-4651 PREPARED BY Doug Moody DATE 1/10/05 BUILDING ADDRESS 2038 Corte Del Nogal Suite 100 BUILDING OCCUPANCY B TYPE OF CONSTRUCTION' VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 5761 cb Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 178,591 178,591 1994 UBC Building Permit Fee $789. 1994 UBC Plan Check Fee $513.42 Type of Review CD Repetitive Fee~^~| Repeats Complete Review D Other i- Hourly Structural Only Hour* Esgll Plan Review Fee $442.33 Comments Sheet 1 of 1 macvalue doc • * PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE Docs/Mlsforms/Plannlng Engineering Approvals ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant Ah Calculation based on building plancheck plan submittal Address ##2< (jZT-^Qd AJa$*,l -&I<>O Bldg Permit No Prepared by ~tp Date Checked by Date EDU CALCULATIONS: List types and square footages for all uses Types of Use dftlU *> O&C, Sq Ft /Units Types of Use _ Sq Ft /Units APT CALCULATIONS: List types and square footages for all uses Types of Use 6/^M, ** &&- Sq Ft/Units . Types of Use Sq Ft/Units _ EDU's EDU's ADT's ADT's FEES REQUIRED: WITHIN CFD $TES (no bridge & thoroughfare fee in Distnct #1 , reduced Traffic Impact Fee) D 1 PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS =$ {(f"2 TRAFFIC IMPACT FEE ADTs/UNITS FEE/ADT =$ D NO D D * D D 3 BRIDGE AND THOROUGHFARE FEE ADTs/UNITS 4 FACILITIES MANAGEMENT FEE UNIT/SQ FT . 5 SEWER FEE EDU's atiO^) BENEFIT AREA ^) EDU's 2. tf*> 6 SEWER LATERAL ($2,500) 7 DRAINAGE FEES PLDA ACRES (DIST #1 DIST #2 X FEE/ADT ZONE X FEE/SQFT/UNIT X FEE/EDU ^^ X FEE/EDU \O^ HIGH /LOW X FEE/AC DIST #3 _ =$ =$ =$ =$ , =$ =$ ) I 400.35* &KS.J5- 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION F \FEE CALCULATION WORKSHEET doc 1 Of 2 Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $ *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. $ooo -_ 115: 2 of 2F \FEE CALCULATION WORKSHEET doc Rev 7/14/00 DDD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner APN. O"*Address Phone (760) 602- Type of Project & Use Zoning* Vi\l\ General Plan CFD (in/out) #_Date of participation*. Net Project Density: A//A DU/AC Facilities Management Zone:. Remaining net dev acres*. Circle One (For non-residential development Type of land used created by this permit: ) Legend: 03 Item Complete Q Item Incomplete - Needs your action Environmental Review Required: YES NO TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval* Discretionary Action Required: APPROVAL/RESO NO. PROJECT NO. YES NO. DATE .TYPE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval* ODD Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES NO If California Coastal Commission Authority* Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log #, Follow-Up Actions: 1) Stamp Building Plans as "Exempf or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. D D D Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: H VADMINVeOUNTEf-ftBldgPlnchkRevChklst Rev 9/01 [] [U n 1 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). D EH Q 2. Provide legal description of property and assessor's parcel number. ODD nan nan ODD Policy 44 - Neighborhood Architectural Design Guidelines NO 2. Project complies YES Zoning: 1. Setbacks: Front: Interior Side: Street Side- Rear: Top of slope: 2. Accessory structure setba Front: Interior Side: Street Side. Rear: Structure separation: 3. Lot Coverage 4. Height- 5. Parking. Spaces NO Required Required Required Required Required cks: Required Required Required Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments A 'fput 'bar sit OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H-\ADMIN\COUNTER\BldgPlnchkRevChklst DATE. Rev 9/01 Carlsbad Fire Department 044651 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 01/04/2005 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address Me Ardle Assoc 5838 Edison Place Suite 201 City, State Carlsbad CA 92009 Plan Checker Job Name Hunter Chase Job # 044651 Job Address 2038 Corte Del Nogal Bldg # CB044651 Ste or Bldg No 100 Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards D Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1 st 2n<1 3rd 044651 FD File # Other Agenny ID 7607370931 04/26/2005 08 14 7607370931 05- 4-26, 7 42AMiBadlands Engineering COMPETITIVE EDGE CON REPLANPS ENGINEERING COMPANY, INC ELECTRICAL CONSULTING ENGINEERS 525 NEW JERSEY STREET. STE A, REDLANDS. CA 92375 (909) 792-0611 fax- (9(79) 792*0596 *mail- tlnB6«6ebcg1olMO nst FACSIMILE TRANSMITTAL PAGE 01 #1/3 Date & Time 0426/5 7:43 am Number of pages Including this sheet* 3 total To: Company: Attention: Phone, pax- CG£ Chris Sass $19-521-2022 From: Name: Sue Hutse Project Hunter Chase Project* 04268 CC: Kfflly, Competitive Ed0e Construction McArdle Architects Associates Remarks: Attached is the revision that was requested be made to the single line drawing due to field conditions encountered. Please contact us if you need additional Information. (H*rd copy ID MeAnto Architects Associates) if any portion of this transmission is illegible or incomplete, please notify our office immediately. Thank you. - 04/-26/200S 08 14 7607370931 06- 4-26; 7.42AM,Red lands Engineering COMPETITIVE EDGE CON PAGE 02 ,8097926696 * 2/ 3 Kroarw LIME niAQRAM HUNTER CHASE REDLAND8 COMPANY, INC, SCALE DATE NOSCME 0+-2S-D6 DftAWINC NUMBERE-5a 04/26/2005 08 14 7607370931 05- 4-28; 7 42AM,Rsdlands Engineering COMPETITIVE EDGE CON PAGE 03 ,9097926598 * 3/ 3 SCHEDULE. - 4* C.O. (CONDUCTORS BY UTWlf) - ft} f to. (CONDUCTORS BY mm) - URR GROUND Vf OF P/Q CU, W BOUW A 2 S fF - a'e.4 /?/n / /B eat - /-?/?' C.O STUBBED INTO FUTURE LEASE SPACE - EXBVNe CONDUIT AND CONQUCTMS - J/4" C., 1 jff WOUND TO 5/5' x 10' &MOND MO NOTES: /. AU. ELK1KCAL SIUPUEHT 1NOKAJ& ON MS &MMW SHALL K NEW, tWISS NOTED OTHERHSZ. AS SERtS-RATEQ2 OWCW&r K^ ^CLOSURES WJ. AND LABELED IN ACCORDANCE mi NEC 110-22. &AU.RAW P£R 4 ALL COWCrOtt SHAU. K &PP& TW '7HW' OR & AU CffKUir BREAKERS SHALL 8£ SEKES RATE). KEYNOTES. 1) ALL ORCW BRM^ LOCATSD IN 1HK PAN^ SHAtl OF 42,000 AUPS SmKUKAL AT 208 VOL1S USMJU ALL OKCtUT BRAKE® LOCATED M THIS PANEL SHALL HA\f A HNNUIt INTERRUPTING CAPACITY OF 30.000 AUPS SnUETOCAL AT 208 W.JS HUNTER CHASE HSDLANDS £NaJJM££EJNQ COMPANY, INC. *•tan (HI) 792-4111 Fit (Mft) ItMfiW PROJECT NUMBER 04268 SCAl£HQStME OATC DRAWING NUMBERE-5b HUNTER CHASE REVISION 4-25-05 McMk APPROVAL. DATE. HUNTER CHASE REVISION 4-25-05 APPROVAL. DATE.