Loading...
HomeMy WebLinkAbout2039 CORDOBA PL; ; CB901756; PermitBUILDING PERMIT 12/27/91 14 13 Page 1 of 1 Job Address 2039 CORDOBA PL Sti Permit Type RESIDENTAL ADD/ALT (UNDR $10K) Parcel No 207-240-36-00 Valuation 2,000 Construction Type VN Occupancy Group Class Code Description 27 SF ADD PLUS REMODEL Fl Permit No CB901756 Project No A9001992 , Development No / \/ ^Sf^ff' Ste tJ^oio Status ISSUED lied Appl/Ownr WALKER, KARL 2039 CORDOBA PLACE CARLSBAD, CA 920-08 **•* Fees Required *** Validated 619 434-4792 Fees .'Collected & Credits 0 0 23-00 * * * Fees 1 Adjustments Total Fees 1 Fee description Building Permit ; o. Plan Check i Strong Motion Fee Other * BUILDING TOTAL Enter "Y" for Plumbing Each Plumbing Fixture * PLUMBING TOTAL Enter "Y" for Electric Other * ELECTRICAL TOTAL ($1 26.,. 00' ... , , -''-oo ..•-' ~v-:-. ,26 X>0 / "'•• -. "" •' «-. -- - ." / ' X^'"1^- "' • ' ' V """":- ..../.' ; X •••' • c'v/l "X i V. / ;// '. • ''••. ' ... > - "V-. Issue Fee > or Trap >'- Issue Fee > > 0 Minimum) • Total Credit s: '. -•';•;/; -Total Payment; s • \ " Balance Due • ; \ •;;;.:::^::;::=:.-:yn;3;-t;s!;>'' F<3Q'/,Ur; i t\ ••-•'•". . " " .-•-••"•':' _/_'' '• ~ s ,:'' •'''"'': :" 1 •-,•'••->> ,-/' ..:;;• ;'-..' 1 1 X'-- - ' I '''. !'i^ ^ I ? :-'\~ f : ^ •• i! ': 23''- tVfr,1' '/ '• -"'.•'.•, :'. f •'"'. •' .O--O-MK-; 2 •"-.. 2 50 '" ' .. ..•••. .-,'-. 10- 00 - 103 23 Ext f« 45 29 1 23 98 7 5 13 5 10 15 00 00 00 se Data 00 00 00 00 RENEWAL 00 50 Y 00 00 00 Y 00 REMODEL 00 CITY OF CARLSBAD 2075 Las Palmas Dr , Carlsbad, CA 92009 ^519) 438-1 BUILDING PERMIT 12/28/90 16 11 Page 1 of 1 Job Address 2039 CORDOBA PL Str Permit Type RESIDENTAL ADD/ALT (UNDR $10K) Parcel No 207-240-36-00 Valuation 2,000 Construction Type VN Occupancy Group Class Code Description 27 SF ADD PLUS REMODEL Permit. No CB901756 Project No A9001992 Development No Fl Ste 0090 12/28/90 0001 01 02 C-r>"T 74- C( Appl/Ownr WALKER, KARL 2039 CORDOBA PLACE CARLSBAD, CA 92008 Status ISSUED Applied 10/31/90 Api/Issue 12/28/90 Validated By DC 619 434-4792 *** Fees Required * Fees 10 Adjustments Total Fees 10 Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbing Each Plumbing Fixture o A PLUMBING TOTAL Enter "Y" for Electric Other •A ELECTRICAL TOTAL ($10 •* * * * A 3 00 00 3 00 Issue Fee > r Trap > Issue Fee > > Minimum) Fees Collected & C Total Credits Total Payments Balance Due Units. Fee/Unit 2 00 2 50 •• ', 10,0 0 r edits 29 74 Ext f« 45 29 1 75 7 5 13 5 10 15 00 00 00 ;e 00 00 00 00 50 00 00 00 00 00 * * A Data Y Y REMODEL FINAL APPRWAL INSP. CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr, Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr , Carlsbad, CA 92009 (ei9) 438-nei L PERMIT TYPE ~A Q COMMERCIAL DNEWQ TENANT IMPROVEMENT B O INDUSTRIAL DNEW QTENANT IMPROVEMENT c ^RESIDENTIAL DAPARTMENT QCONDO ^SINGLE FAMILY DWELLING J^ADDITIONQLTERATIO DDUPLEX QDEMOLITION DISLOCATION QMOBILE HOME QELECTRICAL Q]MECHANICAL QPOOL QSPA QRETAINING WALL Dst>i-AR D°THER_ EST VAL CTO G ^ ^ PLAN CIC DEPOSIT «=*<: / VALID BY /i^" DATE sSQ/*S//9& 9358 10/33/90 0001 0? 02 C-PRMT ?°.00fcUtt 2 PROJECT INFORMATION S^t/\ tit PLAN CHECK No TcY " ' " Address 20^ ^O^bbft Pb&t, Nearest Cross Streets Hlll&dtiL jDriYfc. •^ LEGAL DESCRIPTION Lot No CHECK BE LOU IF SUBMITTED Q2 Energy Calcs Q2 Structur ASSESSOR S PARCEL i/)*1 « J^\Q «-3 Subd i v j s i on I Calcs L Bui Idmg or Sui te No &CMIO 4fe**#. Name/NSiilbcrRfw;er<s A? ^r ^ FOR OFFICE USE ONLY Unit No Phase No d] 2 Soils Report D1 Addressed Envelope EXISTING USE 5)«L*X*,l&r> . PROPOSED USE< 1 CLe,M»^ BLOG SO FTG 37 &# OF STORIES l-te-\tK\\ CONTIACT PERSONi Ute lK<r TED/4 ADDRESS £03^ <W0i* f). ZIP CODE J%.OQ(>DAY TELEPHONE ™ ' '" * SIGNATURE APPLICANT NAME CITY QCONTRACTOR Q AGENT FOR CONTRACTOR ADDRESS ZIP CODE nAGENT FOR OWNER DAY TELEPHONE PROPERTY .OWNER CITY f CtfrlsbaA M DLESSEE QTENANT ZIP DAY TELEPHONE 6 CONTRACTOR NAME ADDRESS ZIP CODE DAY TELEPHONE STATE LIC #LICENSE CLASS CITY BUSINESS LIC # SIGNATURE DATE IRKERS' COMPENSATION Workers Compensation Declaration I hereby affirm that I have a certificate of consent to self insure issued by the Director of Industrial Relations or a certificate of Workers Compensation Insurance by an admitted insurer or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800 Lab C) INSURANCE COMPANY EXPIRATION DATE Certificate of Exemption I certify that in the performance of the work for which this permit is issued 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION Owner Builder Declaration I hereby affirm that I am exempt from the Contractor s License Law for tne following reason | | i as owner of the property or my employees with wages as their sole compensation will do the work and the structure ib not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale ) n I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who buttds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) I1 I am exempt under Section Business and Professions Code for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9 commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [S500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' DYES QNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 DYES DNO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' DYES QNO IF ANY OF THE ANSWERS ARE VES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097( i ) Civil Code) LENDER'S NAME LENDER S ADDRESS 10 APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct I agree to comply with all City ordinances and State laws relating to building construction I Hereby authorize reprcsentativcs of the City of Carlbbad to enter upon tne above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH HAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration everyjterni]t issued by the Building Official under the provisions of this Code shall expire by (imitntion and become null and void if the building or worJ^authon zedlt\ slch permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or_ ab/ipoVcd ft anj \in§ after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code) OWNER I CONTRACTOR PHONE APPROVED BY DATE E File YELLOW Applicant PINK Finance DATE 12/10/91 TO WALKER, KARL 2039 CORDOBA PLACE CARLSBAD, CA 92008 RE BUILDING PERMIT EXPIRATION PERMIT NUMBER CB901756 ISSUE DATE: 12/28/90 LAST INSPECTION PLEASE CALL FOR AN INSPECTION IF WORK IS COMPLETE ADDRESS 2039 CORDOBA PL Our records indicate that your building permit will expire by limitation of time on 12/28/91 The provisions of UBC, Section 303(d) state "EXPIRATION. Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within one calendar year from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of six consecutive calendar months or if the building or work authorized by such permit exceeds three calendar years from the issuance date of permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the building official within one year of the date of permit issuance Work shall be presumed to be stopped if the permittee has not ob- tained a required inspection approval of work by the building official within each six month period upon the initial commencement of work authorized by such permit Before such work can be recommenced, a new permit, or a renewal permit as specified below, shall be obtained 1 PERMITS WHERE WORK HAS NOT COMMENCED For permits where work has not ccnrenced jn the first calendar year from the date of issuance, a renewal permit may be obtained provided (A) No changes have been made or will be made in the original plans and specifications for such work (B) That the expiration has not exceeded three years from the original issuance date (C) That the same edition of the model codes is in effect as used in the initial plan check (D) That a fee equal to one-half the amount required for a new permit be paid. The renewal permit shall expire three calendar years from the date of initial permit issuance 2O~75 Las Palmas Drive Carlsbad California 92OO9 « (619) 438-1161 Page Two Where later editions of the model codes have been adopted than used in the initial plan check, such applications for renewal shall be considered as a new plan check submittal. Accordingly, plans shall reflect the requirements of the current codes in effect, a full new plan check is required, and a full new plan check fee shall be paid. Upon completion of a new plan check, the permit may be renewed upon payment of a permit fee equal to one-half the amount re- quired for a new permit. The renewal permit shall expire three calendar years from the date of initial permit issuance 2 PERMITS WHERE WORK HAS COMMENCED For permits where work has commenced and was subsequently stopped as defined herein, a renewal permit may be obtained provided: (A) No changes have been made or will be made in the original plans and specifications for such work I (B) That the expiration has not exceeded three years from the issuance date. (C) That a fee equal to one-half the amount required for a new permit be paid, except that where construction has progressed and has been approved to the point of requiring only a final inspection, a fee equal to one-quarter the amount required for a new permit shall be paid A renewal permit shall expire three calendar years from the date of initial permit issuance." Please check below indicating your intentions and return this letter to us Project abandoned. A new permit will be obtained prior to commencing work. z Extension requested for 180 days, (explanation letter attached) Renewal permit requested. If you have any questions, please contact the Building Inspection Department at 438-1161 extension 4208. PAT KELLEY "' Principal Building Inspector ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O1468 DATE JURISDICTION <LlTY PLAN CHECK NO: ty £) -SET- PROJECT ADDRESS; <$?Q3? O&GJfo&A j>L. PROJECT NAME U)ALt(e£. QAPPLICANT^JURISDICTIONQPLAN CHECKER QFILE COPY QUPS ("DESIGNER D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check he been completed. Person contacted- Date contacted: REMARKS: 7 Enclosures:By ESGIL CORPORATION/A -/#- 9z> UGA UAA URN QDM ESGIL CORPORATION 932O CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-I46S DATE A)D\/eiM6£-£. 3D. /9?D HAPPLICANT JURISDICTION (JiT V ftf- <*>?>&.«=. A fl£> [_jPLAN CHECKER QFILE COPY PLAN CHECK NO ^d'/ISio SET jTC. Dups f~. DESIGNER PROJECT ADDRESS $039 PROJECT NAME- i The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person The applicant's copy of the check list has been sent to. Esgil staff did not advise the applicant contact person that plan check has been completed. I I Esgil staff did advise applicant that the plan check has — been completed. Person contacted- _ Date contacted: Telephone # REMARKS By: /jJVj^^£S}WU#idtJL> Enclosures ESGIL CORPORATION DGA DAA DRN QDM JURISDICTION _Date plans received by plan checker 11 '^ *? - 7 D PLAN CHECK NO PROJECT ADDRESS TO Date plan recheck completed (I '3 0^0 By RECHECK PLAN CORRECTION SHEET FOREWORD PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access The plan check is based on regulations enforced by the Building Inspection Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The items shown below need clarification, modification or change All items have to be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A PLANSOPlease make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to QlL 3 )The following items have not been resolved V Jfrom previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the still outstanding corrections Please contact me if you have any questions regarding these items OTo facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made to 'the plans not resulting from this correction list7 Please check Yes Form No RPCS 41290 1 Sleeping rooms shall have a window or exterior door for emergency exit Sill height shall not exceed 44" above the floor The window roust have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" Section 120*4 Basements in duelling units shall comly v,ith the above (even if not designated as sleeping rooms) Section 1204 Walls and floors separating units in a duplex shall be of one-hour fire-resistive construction Section 1202(b) A mezzanine is an intermediate floor and nay not have a floor area exceeding 33 1/3 percent of the total floor area in the room below The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height Section 1716 The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story Section 1716 EXITS. STAIRWAYS. AND RAILINGS Floors above the second story shall have not less than 2 exits Exceptions 1 Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than innaediately above the second storv 2 When the third floor within a unit does not -exceed 500 sq ft , orly one exit need be provided Section 3303(a)" Required exit doorways shall be not less than 36" in v,idth and not less than 6'8" in height, and shall be capable of opening at least 90 degrees Section 3304 (f) Provide 36" high protective railing for porches, balconies, and open sides of stair landings Openings between railings shall be less than 6" Section 1711. Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail Table 23-B tone PtdLfiueu TO Provide stairway and landing details 3306 (b), (c) and (p)Sec Maximum rise is 7" and minimum ru 11" When the stairs serves less ths occupants, or serves an unoccupied i rise nay be 8" maximum and rur roinirnum Minimum headroom is 6 "-8" Minimum vidth is 36" All handrails per Section 3306 (j), satisfy the following a Proxide handrail for stairways vith more risers Handrail shall be nosing of treads to 38" abo\ c The handgrip portion of handrail sh.; not less than 1 1/2", nor more than cross-sectional dimension Every stairway landing shall have a dimer raeasured in the direction of tra\el, at equal to the stairway vidth Such die need not exceed 36 inches Section 330 3304 (]) An interior door may open invard at t. step of a stairway provided the top £ not more than 7 1/2" lover than the level Section 3304 (i) Provide details of vinding stairway con- vith Section 3306 (d) a Mininum tread is 6 inches at an and minimum 9 inches at a point 12 from where the treads are narrovesr b Maximum rise is 8 inches c Minimum width is 36 inches 5/10/90 Provide spiral stairway details, per Section 3306 (f) a Minimum run is 7 1/2 inches measured at a point 12 inches from v,here the treads are the narrowest b Maximum rise is 9 1/2 inches Maximum clear opening between risers is 6 inches c Minimum headroom is 6 feet 6 inches d The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail Spiral stairways may not be used for required exits vhen the area served is greater than 400 sq ft Section 3306 (f) Provide I C B 0 Research Peport and number for metal stairway, or submit plans and calculations and approved fabricator registered v,ith the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation Exterior stairways shall not project into the 3 foot setback from the property lines Section 3306 (n) The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction Section 3306 (m) Q: Within units, show that minimus width of 36 inches ROOFING corridors ha\e a Section 3305 (b) '6 Specify roof slope Roof slope is not adequate for roof type specified Table 32-B,C,D and E Specify roof material and application Chapter 32 Specify I C B 0 or U L approval number for roof materials not co%ered in U B C , e g , tile, etc Section 107 Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water Section 3207 (a) and Section 2305 (f) Show roof drains and overflows Section 3207 'Provide skylight details .to show complianc \^S with Sections 3A01 and 5207 or provn I C B 0 approval number /';J Plastic skylights must be separated from ea other by at least 4 feet Section 5207 (a) 6 Show attic ventilation Minimum vent area 1/150 of attic area or 1/300 of attic area at least 50% of the required vent is at lea 3 feet above eave vents or cornice vent Show required area and area provided Section 3205 (c) MASONRY f Provide fireplace construction details or nc construction to be per attached firepl- standard drawing Chapter 37 Show anchored veneer support and connecti. attached to wood in Seismic Zones 3 and comply with Section 3006 (d)l and Section 2 (a) Show ties and #9 wire in horizon joints Show height and construction details of masonry walls Chapter Ik Show floor and roof connections to masc v>alls Connection shall resist 200 pounds lineal foot or the actual design Ic whichever is greater Cross grain tensio- bending in wood ledgers is not permitted Section 2310 '9 Show a minimum 2" air space and f lasv betveen planter and building walls Section 2516 (c) 7 '/ X GARAGE AND CARPORTS Garage requires one-hour fire protectio' the garage side of vails and ceiling conmc the duelling. Table 5-B, Section 503 (d) All elements supporting floor above gar including walls supporting floor joists, have one-hour fire-resistive protection or garage side Section 503 (b) Show 1 3/8" solid core self-closing door openings between garage and dwelling Sec 503 (d) Garages are not permitted to open into a used for sleeping purposes Section 12/11/89 All structures require a Class B roof covering, Enclosures except room additions If a room addition covers all of the existing building (2nd story 1 _ addition), then the above exception doesn't apply 2 ___ City Ordinance 9792 requires two parking spaces/unit with clear area of 20'x20' i e no washing machines, etc Show compliance 3 _ _ LO H- UflSH££.* OWiSR, All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester Ihe net free area of the spark arrester shall be _ _ not less than four times the net free ara of the outlet of the chimney The spark arrester _ screen shall have heat and corrosion resistance equivalent to 12 gauge wire, 19 gauge _ _ galvanized wire or 2^ gauge stainless steel Openings shall not permit the passage of _ spheres having a diameter larger than 1/2-inch and shall not block the passage of spheres _ having a diameter of less than 3/8-inch Please see additional corrections, or remarks, on the following page To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list7 Please check _ Yes _ No The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number 619/560-1468, to perform the plan check for your project If you have any questions regarding these plan check items, please contact l L l at Esgil Corporation If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr , telephone 619/438-1161 Thank you 2/1W90 ~ " ' IT ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O14«8 DATE JURISDICTION CARLSBAD PLAN CHECK NO- <?Q SET PROJECT ADDRESS <2o.39 <*/)fe/3Ofe/> PROJECT NAME- 1/JPn.Kgfe. APPLTCANTJUR i s D i CT i ON CHECKED COPY QUPS P. DESIGNER D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction1 s -building codes when minor deficien- cies identified _ are resolved and checked oy building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resuomitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of t«.e cneck list is enclosed for the }urisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: . (LA Esgil staff did not advise the applicant contact person that plan check has been completed Esgil staff did advise applicant that the plan check has been completed. Person contacted Date contacted: REMARKS: Telephone By; ESGIL CORPORATION H-$"?aDGA DAA DRN QDM Enclosures: PLAN CHECK NO: ~10 r/15' Lf JURISDICTION; CITY OF CARLSBAD TO:k. Q.Q1Q Pi. > CA ENCLOSURES* PROJECT ADDRESS;3 9 (LhfWh&ft f>L. FLOOR AREA: _ g \ >i '6T ') /U V? STORIES: _ ^J> HEIGHT: REMARKS: PLAN CORRECTION SHEET CITY OF CARLSBAD SINGLE FAMILY AND DUPLEX DWELLINGS Date plans received by jurisdiction Date plans received by Esgil Corporation Date initial plan check completed Bv g. P ftKJOS, ulOILTH Applicant contact person l< Li) A U< rT^ Telephone FOREWORD; PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped The plan check is based on regulations enforced by the Building Inspection Department You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments Present California law mandates that residential construction comply with Title 2k and the following model codes 1988 UBC (eff 1/1/90) 1988 UPC (eff 1/1/90) 1987 NEC (eff 10/28/87) 1988 UMC (eff 1/1/90) The above regulations construction, regardless adopted by ordinance apply to residential of the code editions The circled items listed need clarification, modification or change All items have to be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, note on this list for a copy) where each correction item has been addressed i e . plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. List No 12, Carlsbad Single Family Dwelling and Duplex With All Supplements (1988 UBC) PLANS Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to I Oft- Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-11.68 Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to The jurisdiction's building department Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans Section 302(a)7 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation,for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony Section 302(d) Provide a statement on the Title Sheet of the plans that this project shall comply v»ith Title 2k and 1988 UBC, UMC and UPC and 1987 NEC Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot Identify property lines and show lot dimensions and all easements Show location of all cut or fill slopes Show finish floor elevations and show elevations of adjacent finish grade Show drainage patterns with minimnn slopes Section 302(d) 91 Indicate distance from property lines proposed building Section 302(d) to Show on the title sheet all structures, pools, walls, etc included under this application Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included " Clearly show if the lower level is a basement or a story, based on the definitions in Sections A03 and U20 Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination On the cover sheet of the plans, specify any items requiring special inspection, by way of the following REQUIRED SPECIAL INSTRUCTION'S In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 306 of the Uniform Building Code ITEM REQ IF CHECKED REMARKS SOILS COMPLIANCE PRIOR TO FOUNDATION INSP STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER FIRE PROTECTION Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings Table 5-A 12/11/89 i 1 Sleeping rooms shall have a window or exterior door for emergency exit Sill height shall not exceed 44" above the floor The window must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" Section 1204 Basements in dwelling units shall comly with the above (even if not designated as sleeping rooms) Section 1204 Walls and floors separating units in a duplex shall be of one-hour fire-resistive construction Section 1202(b) A mezzanine is an intermediate floor and nay not have a floor area exceeding 33 1/3 percent of the total floor area in the room below The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height Section 1716 The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story Section 1716 EXITS. STAIRWAYS. AND RAUJMGS V Floors above the second story shall have not less than 2 exits Exceptions 1 Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than immediately above the second storv 2 When the third floor within a unit does not •exceed 500 sq ft , orlv one exit need be provided Section 3303(a) Required exit doorways shall be not less than 36" in width and not less than 6"8" in height, and shall be capable of opening at least 90 degrees Section 3304 (f) Provide 36" high protective railing for porches, balconies, and open sides of stair landings Openings between railings shall be less than 6" Section 1711 Provide stairway and landing details 3306 (b), (c) and (p) Section / ©/ Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum Minimum headroom is 6'-8" Minimum width is 36" All handrails per Section 3306 (j), shall satisfy the following a ProMde handrail for stairways with 4 or more risers Handrail shall be 34" nosing of treads to 38" above the c The handgrip portion of handrail shall be not less than 1 1/2", nor more than 2" in cross-sectional dimension Every stairway landing shall have a dimension, measured in the direction of tra\el, at least equal to the stairway width Such dimension need not exceed 36 inches Section 3306 (g), 3304 (i) An interior door may open inward at the top step of a stairway provided the top step is not more than 7 1/2" lower than the floor level Section 3304 (i) Provide details of winding stairway complying with Section 3306 (d) a Minimum tread is 6 inches at any point and minimum 9 inches at: a point 12 inches from where the treads are narrowest b Maximum rise is 8 inches c Minimum width is 36 inches 44 JShow how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail Table 23-B 5/10/90 0 Provide spiral stairway details, per Section 3306 (f) a Minimum run is 7 1/2 inches measured at a point 12 inches from v«here the treads are the narrowest b Maximum rise is 9 1/2 inches Maximum clear opening between risers is 6 inches c Minimum headroom is 6 feet 6 inches d The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail si Spiral stairways may not be used for required exits vhen the area served is greater than 400 sq ft Section 3306 (f) 52 Provide I C B 0 Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation 5p Exterior stairvays shall not project into the 3 ' foot setback from the property lines Section 3306 (n) 5k The walls and soffits of the enclosed usable \ space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction Section 3306 (m) Within units, show that minimum width of 36 inches ROOFING corridors have a Section 3305 (b) 36 Specify roof slope f Roof slope is not adequate for roof type specified Table 32-B,C,D and E 56 Specify roof material and application Chapter 32 5(9. Specify I C B 0 or U L approval number for roof materials not covered in UBC,eg, tile, etc Section 107 60 Specify minimum 1/4 inch per foot roof slope I for drainage or design to support accumulated water Section 3207 (a) and Section 2305 (f) 61 Show roof drains and overflows Section 3207 f i X 'Provide skylight details ,to show compliance with Sections 3401 and 5207 or provide I C B 0. approval number Plastic skylights must be separated from each other by at least 4 feet Section 5207 (a) 6 Show attic ventilation Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents Show required area and area provided Section 3205 (c) MASONRY Provide fireplace construction details or note construction to be per attached fireplace standard drawing Chapter 37 Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a) Show ties and #9 wire in horizontal joints Show height and construction details of all masonry walls Chapter 24 Show floor and roof connections to masonry walls Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater Cross grain tension or bending in wood ledgers is not permitted Section 2310 Show a minimum 2" air space and flashing between planter and building walls Section 2516 (c) 7 GARAGE AND CARPORTS Garage requires one-hour fire protection on the garage side of vails and ceiling common to the duelling Table 5-B, Seqtion 503 (d) All elements supporting floor above garage, including walls supporting floor joists, mist have one-hour fire-resistive protection on the garage side Section 503 (b) Show 1 3/8" solid core self-closing door for openings between garage and dwelling Section 503 (d) Garages are not permitted to open into a room used for sleeping purposes Section 1104 12/11/89 138 Show the size, location and type of all heating and cooling appliances or systems 139 Show source of combustion air to furnace, per Chapter 6, UMC 140 Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms Show basis for compliance UBC, Sec 1212 141 Show minimum 30" deep unobstructed working ' space in front of furnace Section 505, UMC 142 Furnace shall not be installed in any bedroom, ' bathroom or in a closet or confined space vith access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance Section 704 UMC ELECTRICAL (NATIONAL ELECTRICAL CODE) All viring shall Electrical Code comply vith the National 1|51 Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub- panels If service is o\er 200 amps, submit single line diagram, panel schedule and load calculations 2 Show location of all electrical receptacles Electrical receptac is not adequate in_ 15^ Electrical receptacle locations and/or spacing 144 lip I Show I C B 0 approval number for prefab fireplace Show height of chimney above roof per I C B 0 approval or Table 37-B Show access to the attic containing equipment to be minimum 30 inches by 30 inches The opening may 1>e 22 inches by 30 inches if the equipment can be removed through such opening Section 708 UMC Where equipment is installed in the attic, the distance from the attic access to such equipment shall not exceed 20 feet Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide Section 708 UMC Show at least one convenience outlet other than outlets for laundry, etc , outdoors, in garages and basements NEC, Art 210-52 Note convenience outlets in bathrooms, kitchen counter top(s) vithin 6 feet of the kitchen sink, outdoors, and in garages and basements (other than for laundry and similar equipment) shall be GFI protected NEC, Art 210-8. 16 Note electrical system ground per NEC, Art 250-81 to be provided HJMBING (uTOTORM PUMBCTG CODE) Show vater heater size, type and plans UPC, Section 1301 location on (7 Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace Section 708 UMC 148 Show details to comply vith Section 709 for furnace under the floor, or Section 710 for roof or outside furnace it9 >ote on plan Gas vents and non-combustible piping, in vails, passing through three floors \ or less shall be effectively draft stopped at each floor or ceiling UBC, Section 1706 (a) 6 150j Provide dryer vent to outside UMC, Section ^—/ 1903 15J8 Show source for providing combustion air to ' fuel burning vater heater If wall openings in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one-half vithin the lower twelve inches UPC, Section 1307 Fuel combustion vater heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom UPC, Section 1309 Provide adequate barrier to protect vater heater from vehicle damage An 18" platform for the vater heater does not satisfy this requirement UPC, Section 1310 Show I and P valve on vater heater route of discharge line to exterior UPC, Section 1007 (e) and show 1/19/90 106 162 ) Show that water heater is adequately braced to \~J resist seismic forces, when not connected by rigid pipe UMC Section 504(d) 163 Show shower stall can accommodate a 30" circle and has a minimum floor area of 1,024 sq in UPC 909 (d) Provide clothes washer hook-up for each unit Title 24, Part 3 Show details of duplex common (party) walls and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibels and an Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibels Title 24 Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating Title 24 16:7 Provide insulation in walls and ceiling to 1 achieve STC of 50 between garage and living \ area if garage use is not controlled by resident Title 24 ENERGY CONSERVATION 168 Provide plans, calculations and worksheets to show compliance with current energy standards 1<J9 The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-1R 17iL Specify on the building plans all of the [ mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Energy Conservation Requirements" Show the make, model and efficiency of the space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr For room additions, show that the glazing area of the addition does not exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition provide fluorescent general lighting in kitchen(s) per CAC, Title 24, 2-5352(J) CARLSBAD S.F D. & DUPLEX SUPPLEMENT As 177 1805 183 Energy conservation 7 design should be for Zone Floor drains policy) must have auto-prime (city Note exhaust fans cannot be ductless type (city policy) New residential units must be pre-plumbed for future solar water heating Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No 8093) Note "two 3/4" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof (City Ordinance No 8093) All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy) Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s) Show on the Title Sheet on the plans, the information required by the attached Developmental Services Sheet 112383 All new residential buildings, including additions, require a soils report Please submit two copies Exception If a room addition is limited to one story and 1000 sq ft in area, then a soils report is not required Esgil Corporation will advise the City to place their soils notice stamp on the plans Heavy timber framing, minimum 6" x 10" begins and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans (city policy) 2/26/90 10 185 All structures require a Class B roof covering, Enclosures ' except room additions If a room addition covers all of the existing building (2nd story 1 addition), then the above exception doesn't apply I 186 Jcity Ordinance 9792 requires two parking x__x spaces/unit with clear area of 20'x20l i e no washing machines, etc Show complianceLo H, kJASHeje.*D«.Y<::£. 1&7 All chimneys attached to any appliance or ' fireplace that burns solid fuel shall be equipped with an approved spark arrester the net free area of the spark arrester shall be not less than four times the net free ara of the outlet of the chimney The spark arrester screen shall have heat and corrosion resistance equivalent to 12 gauge wire, 19 gauge galvanized wire or 24 gauge stainless steel Openings shall not permit the passage of spheres having a diameter larger than I/2-inch and shall not block the passage of spheres having a diameter of less than 3/8-inch KISCELLAKEOUS Please see additional corrections, or remarks, on the following page 189 \ To speed up the recheck process, note on this 'list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc [ 190 A Please indicate here if any changes have been V ^made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list' Please check Yes No The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number 619/560-1468, to perform the plan check for your project If you have any questions regarding these plan check items, please contact _ L t'j^ti P fHlrts u at Esgil Corporation If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr , telephone 619/438-1161 Thank you 2/14/90 Prepared "by i Jurisdiction CART.SRAD VALUATION AND PLAN CHECK *"££ Q Bldg. Dept. D Esgil PLAN CHECK NO.. BUILDING ADDRESS APPLICANT/CONTACT ft BUILDING OCCUPANCY __ TYPE OF CONSTRUCTION PHONE NO. DESIGNER PHONE CONTRACTOR PHONE BUILDING PORTION fltrwidDtn- Air Conditioning Commercial Residential Res. or Comm. Fire Sprinklers Total Value BUILDING ARE.^ Ptne. <LITV \J» — VALUATION l-'ULTIPLIER -LiJt^reoJ @ § § VALUE £oaa c^ooo Building Permit Fee $_ Plan Check Fee $ COMMENTS SHEET / OF /12/87 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER I/A A/DATE ENGINEER DATE Co NJW C \WP51\FILES\BLDG FRM Rev 10/31/90