HomeMy WebLinkAbout2042 CORTE DEL NOGAL; C; CB021089; Permit07-01-2002 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB021089 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title Applicant TONY MANSOUR SUITE 111 5897 OBERLIN DR SD 92121 858-558-1509 2042 CORTE DEL NOGAL CBAD Tl Sub Type 2130610500 Lot# $119,700 00 Construction Type Reference # EPIGEN X/ 3990 SF OFFICE TO OFFICE, INSTALL SHOWERS, ELEC & MECH COMM 0 NEW Status APPROVED Applied 04/09/2002 Entered By CB Plan Approved 07/01/2002 Issued Inspect Area Owner QUINCE ASSOCIATES LTD C/0 SPECTRUM PROPERTY MANAGEMENT 8799 BALBOA AVE #260 SAN DIEGO CA 92123 Total Fees $1,24760 Total Payments To Date $395 30 Balance Due $852 30 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $60816 Meter Size $0 00 Add'l Reel Water Con Fee $395 30 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $2514 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $10400 $6000 $5500 $000 $000 $000 $000 $1,24760 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise exoired Plan Ck Deposit Validated B Date PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr, Carlsbad CA 92009 (760)438-1161 FOR OFFICE USE ONLY PLAN CHECK Address (includeBlflg/Suite #) Ml- ^ 0F GAptSMG Legal Description ' ' /Business Name (at this address)*o*eo-'*>f- *Jy> /0e£ jbdivision Name/Number' / unit NoLot Kl Phase No Total # of units Asse'ss"or's Parcel # / Description of Work 2 CONTACT PERSON (if differen/frbm applicant) PVofrosed Use #of Stories # of Bedrooms # of Bathrooms 4644 04/09/02 0002 01 02 Namef /7 Address City 3 APPLICANT " D^bntractor.::|!EliSAgent for Contractori:HjD Owner Regent for;Owner State/Zip Telephone # Fax # Nam'e ' f If 4 PROPERTY OWNER Address City State/Zip Telephone #Name :5 CONTRACTOR- COMPANY NAME -'" ' W .J3 ' ^ - ••—• "" "f*• . .";»•' (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exerpption _ /^n^ violation of Section 7031,5 by any applicant for a permit subjects the applicant taa civil penalty of not more than five hundred dollarsj $ 5001] if- £[ e_ n-gJy^ j^ytgci/'f'Je j/f\ Jxwi yf'gr;^ Name State License # Address License Class City ' ~ State/Zip City Business License # Telephone ^7 ^ Designer Name Address City State/Zip Telephone State License # "6""" WORKERS' COMPENSATION "'" , '™:i' ::"": :-;tr 4ii:" ' """"">' -. •-„. "><s IP" "Vf- """"™ Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued H"""! have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance earner and policy number are Insurance Company rrf^\ ^-f^l CO'-vs (y&^M^O-^J^ ££ Policy No LAJl- *"iJ -^-^ /~O "C Expiration Date /O~ Q f " C) -<>. (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) F~) CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensaty»f^-aws of California WARNING Failure to secure--^>rkers com<y(isatign_-CPVoragG is-unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&JOOQ0<y^»nadditionitKjme cojful oumuuilUUlioni damages as provided for in Section, 3706 of the Labor code, interest and attorney s fees SIGNATURED" ~^X^C--^_ 3*^^ •y ^ DATE Q " 8 O S, ;7:-::.:- OWI^ER^WltDER DECLARATJ6N J „ ' • r'.*:.i: " "« - - -:;""' -1? vtl^.. I hereby affirm that I am exempt from the Contractor's License Law for the following reason l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) 0 ' am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement f~l YES C]NO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY^ ; i:N flh.s> Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? C3 YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' Q YES l~l NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? d YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 CONSTRUCTION LENDING AGENCY I i I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER S NAME LENDER S ADDRESS 9'; ""APPLICANtVCERTIFICATION ,,, "„;:;::::":::"™::;2;1S;W'r:vr-; ":" "^^,-•• :-=; ... ._ . •;?•• .„...___• I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINSJ^SAHJ CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations'oveT 5'0" deep and demohjjenor construction of structures over 3 stories in height EXPIRATION Every permit issued by the Buildup Offjbial under the provisions of this Code shall expire by limitation and become null and/coid if the building or work authorized by such permit is not commented wimin 365 days>tfom the date of such permit or if the building or work authorize/I by su/h permit is suspended or abandoned at any time after the work is cc/imenceofor a petrtSd of 180 days (Section 106 4 4 Uniform Building Code)/ G ^ APPLICANT'S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance fip*< 02/04/2003 TONY MANSOUR SUITE 111 5897 OBERLIN DR SD92121 Re Application Date 04/09/2002 0 00 00 Plan Check # CB021089 Address 2042 CORTE DEL NOGAL Expiration Date 04/09/2003 0 00 00 Permit Type Tl Description EPIGEN X/ 3990 SF OFFICE TO OFFICE, INSTALL SHOWERS, ELEC & MECH You applied to have your plans checked on the date noted above To date, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall, expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee " In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department Project Abandoned - I will pick up plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2718 Raenette Abbey Building Department EsGil Corporation In Partnership with Government for Building Safety DATE 6/27/O2 Q APPUpANT JURISDICTION City of Carlsbad U PLAN REVIEWER a FILE PLAN CHECK NO 02-1089 SET III PROJECT ADDRESS 2042 Corte Del Nogal Suite C PROJECT NAME Epigenx - TI X] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to X] Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 6/18/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 •* (858)560-1468 •* Fax (858) 560-1576 v V.r- -» EsGil Corporation In Partnership with Government for Building Safety DATE 5/28/02 JURISDICTION City of Carlsbad PLAN CHECK NO 02-1089 SET II PROJECT ADDRESS 2042 Corte Del Nogal Suite C PROJECT NAME Epigenx - TI ELICANT JURIJ CTPLAN REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck !X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Tony Mansour 5897Oberlm Drive Suite 111, San Diego CA 921 21 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Tony Mansour Telephones 858-558-1509 Date contacted S'/2^/o2 (by f/vc) Fax # (fSff) S5S Mail -^ Telephone Fax ^-" In Person REMARKS By Doug Moody Esgil Corporation [D GA D MB D EJ D PC Enclosures 5/16/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858) 560-1468 •* Fax (858) 560-1576 City of Carlsbad 02-1O89 5/28/02 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO O2-1O89 PROJECT ADDRESS 2042 Corte Del Nogal Suite C SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 5/16/02 5/28/O2 REVIEWED BY Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit three new sets of prints to ESGIL CORPORATION B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo City of Carlsbad O2-1089 5/28/02 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue 5 Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served Section 1004 2 4 Please revise the plans to comply. 6 Exits shall not pass through kitchens, storerooms, or spaces used for similar purposes Section 1004 2 2 Two of the exits pass through either the break room or the warehouse, please revise the plans to show complying exits. I EsGil Corporation i In Partnership with Government for Building Safety DATE 4/22/02 a APELJCANT JURISDICTION City of Carlsbad a PTAN REVIEWER a FILE PLAN CHECK NO O2-1089 SET I PROJECT ADDRESS 2042 Corte Del Nogal Suite C PROJECT NAME Epigenx - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Tony Mansour 5897 Oberlm Drive Suite 111, San Diego CA 92121 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Tony Mansour (N.H) Telephone # 858-558-1509 Date contacted q) id 02. (by ^ ) Fax # Mail i/Telephone ^ Fax In Person D REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 4/11/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O2-1089 4/22/02 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 02-1089 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 4/9/02 DATE INITIAL PLAN REVIEW COMPLETED 4/22/02 JURISDICTION City of Carlsbad USE Office ACTUAL AREA 3990 STORIES 1 HEIGHT OCCUPANT LOAD 46 DATE PLANS RECEIVED BY ESGIL CORPORATION 4/11/02 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O2-1O89 4/22/02 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled Section 106 3 3 3 Indicate the use of all spaces adjacent to the area being remodeled or improved 4 Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) Show in this analysis the occupant load of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths 5 Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served Section 1004 2 4 6 Exits shall not pass through kitchens, store rooms, or spaces used for similar purposes Section 1004 2 2 7 If exit signs are required, provide the following notes on the plans, per Section 1003282 a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign b) Exit signs shall be readily visible from any direction of approach 8 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 for the glazing adjacent the new exit door and the glass wall at the boardroom City of Carlsbad 02-1O89 4/22/02 a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position And where the bottom exposed edge of the glazing is less than 60 inches above the walking surface 9 Please provide complete plans for the attachment of the steel support beam, lateral bracing and post attachment for the folding partition Specify manufacturer and approval ICBO number 10 Please provide a section view of the glass wall partition Show a) Specify manufacturer and approval ICBO number b) Method of attaching top plates to structure (NOTE Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load) 11 Please provide construction details for the new gypsum ceiling for the new showers 12 Please provide evidence the controlled access hardware on door #15 is an approved component of the egress system 13 Please revise the panel schedule to show the new HVAC loads 14 Please revise the electrical plans to show a roof mounted receptacle GFCI protected within 25' of the new HVAC equipment 15 Please note or show a disabled accessible transaction counter that is at least 36" long and no more than 28" to 34" high Section 1122B 4 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a City of Carlsbad O2-1O89 4/22/02 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad O2-1089 4/22/O2 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O2-1089 PREPARED BY Doug Moody DATE 4/22/02 BUILDING ADDRESS 2042 Corte Del Nogal Suite C BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING I! AREA II Valuation PORTION (Sq Ft) Multiplier Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 3990 cb City Valuation By Ordinance Reg Mod VALUE ($) 119,700 119,700 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review CH Repetitive Fee Repeats Complete Review D Other ,—I Hourly Structural Only Hour* Esgil Plan Review Fee $60816 $395 30 $340 57 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR (< $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENCINEER DATE Docs/Misforms/Piannlng Engineering Approvals PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 0 ADDRESS DATE RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE Docs/Misforms/Plannmg Engineering Approvals Carlsbad Fire Department 021089 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report 08/06/2002 Fire Prevention (760) 602-4660 Building Plan Reviewed by Name Address MANSOUR ARCH 5897 OBERLIN DR City, State SAN DIEGO CA 92121 Plan Checker Job Name Epigen X Job# 021089 Job Address 2042 Corte Del Nogal Bldg# CB021089 Ste orBldg No 1-71 Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards LJ Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2nd 3rd 021089 FDFile# Other Agenny ID Carfebad Fire Department 021089 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report Q4/16/2002 Fire Prevention (760) 602-4660 Building Plan Reviewed by C Name Address MANSOURARCH 5897 OBERLIN DR City, State SAN DIEGO CA92121 Plan Checker Job Name Epigen X Job# 021089 Job Address 2042 Corte Del Nogal Bldg# CB021089 Ste orBldg No I I Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements LJ Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards \Z\ Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2nd 3rd 021089 FDFile# Othftr Agenny ID Requirements Category: Building Plan Requirement Pending 0514 Provide Technical Report To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to the inspection of the department, the Chief is authorized to require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and the facilities and appurtances situated thereon, to recommend necessary changes Page 1 04/16/02 I LOVELACE ENGINEERING Structural Engineering Services I 1 1n I•• 1 1 1 1 1 1 1 I•• 1 1 STRUCTURAL CALCULATIONS DATE: MAY 13, 2002 PROJECT: EPIGENX T I 2042 CORTE DEL NOGALSTE C CARLSBAD, CA 92130 DESIGNER: MANSOUR ARCHITECTURAL CORP 5897 OBERLIN DR STE 1 1 1 S AN DIEGO, C A 62121 JOB: J02147 NOTE THESE CALCULATIONS ARE INVALID UNLESS BEARING A WET STAMP & SIGNATURE JfP^w\//&/£? y\G>\\W w 1^ No 39734 ^ \Z\1 llS I Exp 12/31/05 Jrnlfi 6496 Weathers Place • Suite 200 • San Diego, California 92121-2958 i www lovelaceeng com • phone 858 535 9U1 fax 858535 JOB I T.X LOVELACE ENGINEERING, INC Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone (858) 535 9111 Fax (858) 535-1989 SHEET NO .OF. CALCULATED BY CHECKED BY . SCALE _ Tl rVf DATE. DATE. i *•» 6- I GOVERNING CODE-. CONCRETE: MASONRY: MORTAR: GROUT: REINFORCING STEEL: STRUCTURAL STEEL: WELDING: SAWN LUMBER: GLULAMS: SOIL: DESiGN CRDTERBA UBC 1931 F'c = 2500 psi, NO SPECIAL INSPECTION REQ'D (U N O ; ASTM C30, F'm= I&00 psf, NO SPECIAL INSPECTION REQ'D rU N O ; ASTM C210, F'c = l800 psi, TYPE S ASTM C416, F'c = 2000 psi ASTM A6I5, Fy= 40ksi FOR *3 AND SMALLER ASTM Afel5, Fy= 60ksi FOR *4 AND LARGER CU N O.) ASTM A36, Fy= 36ksi CSTRUCTURAL SHAPES 4 PLATES; ASTM A500, GRADE B, Fy= 4fcksi ^STRUCTURAL TUBING; ASTM A53, GRADE B, Fy= 3&ksi ^STRUCTURAL PIPE; E10 SERlES-TYP , E90 SERIES FOR A&I5 GRADE 60 REINFORCING BARS SHOP WELDING TO BE DONE IN AN APPROVED FABRICATOR'S SHOP FIELD WELDING TO HAVE CONTINUOUS SPECIAL INSPECT DOUGLAS FIR LARCH, ALLOWABLE UNiT STRESSES AS PER UBC, CHAPTER 23 DOUGLAS FIR OR DOUGLAS FIR/HEM 24F-V4 FOR SIMPLE SPAN CONDITIONS 24F-VS FOR CANTILEVER CONDITION ALLOWABLE BEARING PRESSURE ACTIVE SOIL PRESSURE ACTIVE SOIL PRESSUREfRESTRAlNED; =. PASSIVE SOIL PRESSURE SOIL DENSITY COEFFICIENT OF FRICTION pcf pcf ^.EXISTING NATURAL SOIL PER UBC TABLE 18-l-A SOILS REPORT BY PROJECT NUMBER DATED SOIL CLASSIFICATION LOVELACE ENGINEERING SHEET NO Structural Design and Title 24 Energy Analysis 6496 Weathers Place • Suite 200 San Diego California 92121 6195359111 Phone 619 535 1989 Fa* CALCULATED BY . CHECKED BY SCALE OF .(Co T.rr DATE . DATE . f\o I OT- D £>£.S<r<e..p-r/ F - SV-e" ^ -2/3*1?, - 2x4 ?-o»f L,L Roof P.i E-fc AS S/'OttO fi.. 8 ' o f. /'-'f/ 3> a- 2-' * r 9' D BHJ ira—IIL UVA4 :a i If-*—.k P To of r-t fTi t r*i vwoc 2 ^ 82. i 163 l£S LOVELACE ENGINEERING, INC Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego California 92121 Phone (858) 535-9111 Fax (619) 535-1989 JOB. SHEET NO . CALCULATED BY_ CHECKED BY SCALE OF DATE, DATE. I a ENGINEERING PESIGN IAT* (St » S<»N v Fp = i < i w 1 /» ( Co. - 0. 44- Ma - o .4 4 > I i r« -- i.o -SO ( TAfrLt. U-o) , O, L k~ J) •*A- LfeS x / 1/NlT : - f> I'M D PRODUCT 207 JOB . LOVELACE ENGINEERING Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 SHEET NO CALCULATED BY CHECKED BY I OF \^ DATE DATE SCALE unit dimensions (50TJQ004-007) *-» •. !srnSS««sx,—,—"—-< 9), ^Ea%^E^t,^^ f . »a ac * ^ C'86 '* 3 " c ^ cenrarca -mouiibi. lloorfrft (tern wood c( ens *« ^ —r f HEO 0 HOLE THREADED. WIRE USE SIZES |MAX_1COMOUIT SIZE | . JS|2J2r Sfllaci e«thgi V* 01 1'^ lor power depending on Y«(? t.tt .-.V3L LOVELACE ENGINEERING Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 JOB SHEET NO . CALCULATED BY_ CHECKED BY SCALE DATE _ DATE. LOVELACE ENGINEERING, INC Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego California 92121 Phone (858) 535-9111 Fax (619) 535-1989 JOB_JQ-Z.TT7 SHEET NO .OF_ CALCULATED BY_ CHECKED BY SCALE DATE. DATE. AT t -T 676, IX OC- 7— 7/4').^t^'-o" T*7'' I -516 D PRODUCT 207 I LOVELACE ENGINEERING INC 6496 WEATHERS PLACE STE 200 SAN DIEGO, CA 92121 Title EPIGENXTI Dsgnr TPT Description Job* J02147 Date 11 HAM, 13 MAY 02 I I I I I I I I I I I I I I I Ph (858)535-9111 Fax (858)535-1989 Rev 510300 User KW 0601024 Vcr 5 1 3 22 Jun 1999 Win32(c) 1083 99 ENERCALC Description (B-1) Calculation Timber Member Information Timber Section Beam Width Beam Depth Le Unbraced Length Timber Grade Fb - Basic Allow Fv - Basic Allow Elastic Modulus Load Duration Factor Member Type Repetitive Status ;' B-1 (door exten 6x12 in 5 500 in 11500 ft 800 Douglas Fir Larch psi 1,3500 psi 85 0 ksi 1,6000 1 000 Sawn No Scope Timber Beam & Joist Calculations are designed B-1 (door close 6x12 5500 11 500 800 Douglas Fir Larch 1,3500 850 1,6000 1 000 Sawn No 7/K, Page 1 I s \data\enercalc\enercalc\02\i02147 ecw Calcu I to 1997 NDS and 1997 UBC Requirements | Center Span Data | Span Dead Load Live Load Point #1 DL LL@x Results Mmax @ Center@x = fb Actual Fb Allowable fv Actual Fv Allowable ft| 1600 #/ft 72 00 #/ft Ibs Ibs ft Ratio = 01703 m-k 27 65 ft 800 psi 228 1 psi 1,3393 Bending OK psi 121 psi 85 0Shear OK 1600 57600 1 000 01507 647 1 02 534 1,3393 Bending OK 128 850Shear OK ._____™_™— —™_J Reactions |( @ Left End DL LL Max DL+LL @ Right End DL LL Max DL+LL Deflections Center DL Defl L/Defl Ratio Center LL Defl L/Defl Ratio Center Total Defl Location L/Defl Ratio Ibs: 57600 Ibs 0 00 Ibs 576 00 Ibs 576 00 Ibs 0 00 Ibs 576 00 in -0 095 2,0170 in 0 000 00 in -0 095 ft 8000 2,0170 54000 000 54000 3600 000 3600 -0015 13,1782 0000 00 -0015 6784 13,1782 _____ J I I I I I I I I I I I I I I I I I JOB . LOVELACE ENGINEERING SHEET NO . Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 CALCULATED BY _ CHECKED BY SCALE OF DATE. DATE. '03 02 03 39p Mansour flrchitectural (858) 558-9231 P 2 iModernfolcT PANEL DETAILS PANEL DETAILS ARE NOT TO SCALE Expandable Closure *: 90'Side Stack; . Remote Expandable Closure - '•'-,' •"'• Sir Side Stack " . Remote Expandable Closure - ! ' Parallel Stack r i / 10-HOLD SBERSIDEL Remote Expandable Closure - Offset Stack ' ;. c 531 1 STACK DEPTHNO OF PANELS X 2 7t» * 2' : Btfold Hinged Panel Closure . . : ' • (Flat Slack) •''• ': " V SIDEB SiOEL •ilold Expanoaple Closure ; (Fiat Stack) • ' •'•''' [ -:""---^--w-*"?-*^;-. ^ SMK DEPTH ^NO OFPA«ELSX!W<7 V-.,,. Remote Expandable Closine - 90* Side Stack (Flat Stack} .. STACK DEPTH uilold Expandable Closure :"/ .' (Angle Stick) ' .Remote Expandable Closure • Parallel Stack (Angle Stack) E^Sj'S/SSj, aJRj ( SgNO OF PANELS X 3 75* 2 ( ^ LOVELACEENGINEERING, INC Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone (858) 535 9111 Fax (858) 535-1989 SHEET NO . CALCULATED BY _ CHECKED BY SCALE OF DATE. DATE. NOTE TO FLANCHECKER; THIS SECTION CONTAINS THE FOLLOWING INFORMATION CIF APPLICABLE TO THIS PROJECT; FOR YOUR USE IN CHECKING. THE PLANS FOUNDATION AND FRAMING STRUCTURAL NOTES NAILING SCHEDULE (TABLE 23-ll-B-U SHEARNALL SCHEDULE FOUNDATION PLAN PAD FOOTING SCHEDULES FOUNDATION PLAN HOLDOHN SCHEDULES SPECIAL INSPECTION SUMMARY LIST STRUCTURAL DETAIL DRAWINGS FOUNDATION PLAN FOOTING 4 HOLDOWN CALLOUTS FRAMING PLANS RAFTER, HEADER, BEAM, POST 4 HARDWARE CALLOUTS SHEARWALL LINE LOCATIONS SHEARWALL CALLOUTS JOB . LOVELACE ENGINEERING SHEET NO . Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 CALCULATED BY_ CHECKED BY SCALE OF_ DATE. DATE. EQUIPMENT PLATFORM CN; 2x10 *2 JOIST (.& SPAN; EA END OF PLATFORM, ALIGN W/ EDGE OF PLATFORM • \ (E)2X4 SUBPURLINS « 24" O C CREMOVE AS r -(W U2I0 HANGER FROM NEW JOIST TO CE; 4X12 PURLIN -(E) 4X PURLIN BEYOND ROOF FRAMING TFS0I10 JOB . LOVELACE ENGINEERING SHEET NO n Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 CALCULATED BY _ CHECKED BY SCALE OF DATE. DATE. -CM; EQUIPMENT PLATFORM -CE;2X4 SUBPURLINS « 24" O C (REMOVE AS REO.'D FOR DUCTING; (E) 4X12 *l PURLIN—^ CDIRECTLY BELOWED6E OF PLATFORM; ROOF FRAMING UPGRADE TFS0II1 JOB LOVELACE ENGINEERING SHEET NO _OF.\(p Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 CALCULATED BY_ CHECKED BY SCALE DATE. DATE. EQUIPMENT PLATFORM re; 2x4 SUBPURLINS « 24" OC (CUT FOR (W2X\<Z»- (W 2XI0 *] DIRECTLY UNDER EDGE OF PLATFORM N/ (W U2I0 HANGER TO (E) GLULAM BM < CN; 2XI(Z> BEYOND -REMOVE CEJ2X4 SUBPURLINS AS REQUIRED FOR DUCTING ROOF FRAMING UPGRADE TFS0II2 LOVELACE ENGINEERING Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego California 92121 Phone 858 535 9111 Fax 858 5351989 JOB _ SHEET NO CALCULATED BY _ CHECKED BY SCALE OF DATE. DATE. *4 DOWELS « 12 "OC AROUND PERIMETER OF NEW FOOTING CEPOXY 6" INTO EXIST'G SLAB, 12" INTO FTG ICBO *4345 FOOTING DETAIL FF0I55 I LOVELACE Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 SHEET NO CALCULATED BY . CHECKED BY SCALE OF DATE DATE ' * I I I I 1 1 EXISTING 4x "ROOF PURLIN ,_,,_ __ailfmp _..,-._!,,,,! L_, ROOF I I NEW UNISTRUT P2815 ADJUSTABLE BRACE CONNECTOR W/ (2) 1/2" x 35" WD LAG BOLTS INTO BEAM (TYP FOR ALL) [SEE ARCH FOLDING PARTITION I DOOR ^ l(=:AM I I 1 I I I JOB. LOVELACE ENGINEERING SHEET NO Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 CALCULATED BY_ CHECKED BY SCALE OF DATE. DATE. 10 I I I I I I 1 1 I I 1 LOVELACE ENGINEERING SHEETNO ,,|(p Structural Engineering Services 6496 Weathers Place • Suite 200 San Diego, California 92121 Phone 858 535 9111 Fax 858 5351989 CALCULATED BY_ CHECKED BY SCALE _ OF DATE. DATE. < O O OO2 LL 2 5 or -i^t^^y < $ D -- LU <H- C/3 CC<cr« "^ LU (.9*?a crcc cr ccO LU £ cj O w> LU i£ liSS^p Q- LU C/3 O Q. m — ^.d AH ^^. ••** ^^> I _^ mO-LUU-XXOCQ t- rr- /M J -T|I^ V fXr Ao ^ ^4- A6>^^i '\•c cr t Oo.cr Q.u. < O ofcI- < c -^m ^ l" ^ ^f-P hID -5 ^X 3 /^Q <s- S A) g ?Q <ri^r X oU- % Q vj ^^\ ^<J f\)r* ) ^ T ^ ^^ '^M: ^,.V t^ o \ =* ^v^ -^ r%<^