HomeMy WebLinkAbout2042 CORTE DEL NOGAL; C; CB021089; Permit07-01-2002
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB021089
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
Applicant
TONY MANSOUR
SUITE 111
5897 OBERLIN DR
SD 92121
858-558-1509
2042 CORTE DEL NOGAL CBAD
Tl Sub Type
2130610500 Lot#
$119,700 00 Construction Type
Reference #
EPIGEN X/ 3990 SF OFFICE TO
OFFICE, INSTALL SHOWERS, ELEC & MECH
COMM
0
NEW
Status APPROVED
Applied 04/09/2002
Entered By CB
Plan Approved 07/01/2002
Issued
Inspect Area
Owner
QUINCE ASSOCIATES LTD
C/0 SPECTRUM PROPERTY MANAGEMENT
8799 BALBOA AVE #260
SAN DIEGO CA 92123
Total Fees $1,24760 Total Payments To Date $395 30 Balance Due $852 30
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$60816 Meter Size
$0 00 Add'l Reel Water Con Fee
$395 30 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$2514 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$10400
$6000
$5500
$000
$000
$000
$000
$1,24760
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise exoired
Plan Ck Deposit
Validated B
Date
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr, Carlsbad CA 92009
(760)438-1161
FOR OFFICE USE ONLY
PLAN CHECK
Address (includeBlflg/Suite #)
Ml- ^ 0F GAptSMG
Legal Description ' '
/Business Name (at this address)*o*eo-'*>f- *Jy> /0e£
jbdivision Name/Number' / unit NoLot Kl Phase No Total # of units
Asse'ss"or's Parcel # /
Description of Work
2 CONTACT PERSON (if differen/frbm applicant)
PVofrosed Use
#of Stories # of Bedrooms # of Bathrooms
4644 04/09/02 0002 01 02
Namef /7 Address City
3 APPLICANT " D^bntractor.::|!EliSAgent for Contractori:HjD Owner Regent for;Owner
State/Zip Telephone # Fax #
Nam'e ' f If
4 PROPERTY OWNER
Address City State/Zip Telephone #Name
:5 CONTRACTOR- COMPANY NAME -'" ' W .J3 ' ^ - ••—• "" "f*• . .";»•'
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exerpption _ /^n^ violation of Section 7031,5 by any applicant for a permit subjects the applicant taa civil penalty of not more than five hundred dollarsj $ 5001]
if- £[ e_ n-gJy^ j^ytgci/'f'Je j/f\ Jxwi yf'gr;^
Name
State License #
Address
License Class
City ' ~ State/Zip
City Business License #
Telephone
^7 ^
Designer Name Address City State/Zip Telephone
State License #
"6""" WORKERS' COMPENSATION "'" , '™:i' ::"": :-;tr 4ii:" ' """"">' -. •-„. "><s IP" "Vf- """"™
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
l~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
H"""! have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance earner and policy number are
Insurance Company rrf^\ ^-f^l CO'-vs (y&^M^O-^J^ ££ Policy No LAJl- *"iJ -^-^ /~O "C Expiration Date /O~ Q f " C) -<>.
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
F~) CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensaty»f^-aws of California
WARNING Failure to secure--^>rkers com<y(isatign_-CPVoragG is-unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars (&JOOQ0<y^»nadditionitKjme cojful oumuuilUUlioni damages as provided for in Section, 3706 of the Labor code, interest and attorney s fees
SIGNATURED" ~^X^C--^_ 3*^^ •y ^ DATE Q " 8 O S,
;7:-::.:- OWI^ER^WltDER DECLARATJ6N J „ ' • r'.*:.i: " "« - - -:;""' -1? vtl^..
I hereby affirm that I am exempt from the Contractor's License Law for the following reason
l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
l~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
0 ' am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement f~l YES C]NO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY^ ; i:N flh.s>
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? C3 YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' Q YES l~l NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? d YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8 CONSTRUCTION LENDING AGENCY I i
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER S NAME LENDER S ADDRESS
9'; ""APPLICANtVCERTIFICATION ,,, "„;:;::::":::"™::;2;1S;W'r:vr-; ":" "^^,-•• :-=; ... ._ . •;?•• .„...___•
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINSJ^SAHJ CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations'oveT 5'0" deep and demohjjenor construction of structures over 3 stories in height
EXPIRATION Every permit issued by the Buildup Offjbial under the provisions of this Code shall expire by limitation and become null and/coid if the building or
work authorized by such permit is not commented wimin 365 days>tfom the date of such permit or if the building or work authorize/I by su/h permit is suspended
or abandoned at any time after the work is cc/imenceofor a petrtSd of 180 days (Section 106 4 4 Uniform Building Code)/ G ^
APPLICANT'S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
fip*<
02/04/2003
TONY MANSOUR
SUITE 111
5897 OBERLIN DR
SD92121
Re
Application Date 04/09/2002 0 00 00
Plan Check # CB021089
Address 2042 CORTE DEL NOGAL
Expiration Date 04/09/2003 0 00 00
Permit Type Tl
Description EPIGEN X/ 3990 SF OFFICE TO
OFFICE, INSTALL SHOWERS, ELEC & MECH
You applied to have your plans checked on the date noted above To date, the related building
permit has not been obtained The original plan review application will expire as no building permit
has been issued
Plans submitted and not retrieved from the building department prior to the plan check expiration
date noted above will be destroyed
The provisions of sections 304 (d) of the Uniform Building Code state
"Section 304 9d) Expiration of Plan Review
Applications for which no permit is issued within one year following the date of
application shall, expire by limitation, and plans and other data submitted for review
may thereafter be returned to the applicant or destroyed by the Building Official
In order to renew action on an application after expiration, the applicant shall
resubmit plans and pay a new plan review fee "
In order to provide better service, please indicate your handling choice for the plans originally
submitted and return this letter to the Building Department
Project Abandoned - I will pick up plans within 10 days
Project Abandoned - Plans may be destroyed
If you have any questions, please contact the Building Department at (760) 602-2718
Raenette Abbey
Building Department
EsGil Corporation
In Partnership with Government for Building Safety
DATE 6/27/O2 Q APPUpANT
JURISDICTION City of Carlsbad U PLAN REVIEWER
a FILE
PLAN CHECK NO 02-1089 SET III
PROJECT ADDRESS 2042 Corte Del Nogal Suite C
PROJECT NAME Epigenx - TI
X] The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
X] Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 6/18/02 trnsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 •* (858)560-1468 •* Fax (858) 560-1576
v V.r- -»
EsGil Corporation
In Partnership with Government for Building Safety
DATE 5/28/02
JURISDICTION City of Carlsbad
PLAN CHECK NO 02-1089 SET II
PROJECT ADDRESS 2042 Corte Del Nogal Suite C
PROJECT NAME Epigenx - TI
ELICANT
JURIJ
CTPLAN REVIEWER
a FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
!X] The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Tony Mansour
5897Oberlm Drive Suite 111, San Diego CA 921 21
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Tony Mansour Telephones 858-558-1509
Date contacted S'/2^/o2 (by f/vc) Fax # (fSff) S5S
Mail -^ Telephone Fax ^-" In Person
REMARKS
By Doug Moody
Esgil Corporation
[D GA D MB D EJ D PC
Enclosures
5/16/02 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858) 560-1468 •* Fax (858) 560-1576
City of Carlsbad 02-1O89
5/28/02
RECHECK PLAN CORRECTION LIST
JURISDICTION City of Carlsbad PLAN CHECK NO O2-1O89
PROJECT ADDRESS 2042 Corte Del Nogal Suite C SET II
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED
ESGIL CORPORATION 5/16/02 5/28/O2
REVIEWED BY Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
A Please make all corrections on the original tracings and submit three new sets of prints to
ESGIL CORPORATION
B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections Please contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
QYes QNo
City of Carlsbad O2-1089
5/28/02
Please make all corrections on the original tracings, as requested in the correction list
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted in one of
two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
These corrections are in response to items not fully addressed or as the result of
information provided, the text in bold print indicates the unresolved issue
5 Exits should have a minimum separation of one-half the maximum overall diagonal
dimension of the building or area served Section 1004 2 4 Please revise the plans to
comply.
6 Exits shall not pass through kitchens, storerooms, or spaces used for similar purposes
Section 1004 2 2 Two of the exits pass through either the break room or the
warehouse, please revise the plans to show complying exits.
I EsGil Corporation
i In Partnership with Government for Building Safety
DATE 4/22/02 a APELJCANT
JURISDICTION City of Carlsbad a PTAN REVIEWER
a FILE
PLAN CHECK NO O2-1089 SET I
PROJECT ADDRESS 2042 Corte Del Nogal Suite C
PROJECT NAME Epigenx - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Tony Mansour
5897 Oberlm Drive Suite 111, San Diego CA 92121
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Tony Mansour (N.H) Telephone # 858-558-1509
Date contacted q) id 02. (by ^ ) Fax #
Mail i/Telephone ^ Fax In Person
D REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 4/11/02 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
City of Carlsbad O2-1089
4/22/02
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 02-1089
OCCUPANCY B
TYPE OF CONSTRUCTION VN
ALLOWABLE FLOOR AREA
SPRINKLERS'? YES
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 4/9/02
DATE INITIAL PLAN REVIEW
COMPLETED 4/22/02
JURISDICTION City of Carlsbad
USE Office
ACTUAL AREA 3990
STORIES 1
HEIGHT
OCCUPANT LOAD 46
DATE PLANS RECEIVED BY
ESGIL CORPORATION 4/11/02
PLAN REVIEWER Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
City of Carlsbad O2-1O89
4/22/02
Please make all corrections on the original tracings, as requested in the correction
list Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
1 Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes Business and
Professions Code
2 Provide a note on the site plan indicating the previous use of the tenant space or
building being remodeled Section 106 3 3
3 Indicate the use of all spaces adjacent to the area being remodeled or improved
4 Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) Show
in this analysis the occupant load of each area, the general exit flow patterns (by
using arrows), accumulated occupant loads and required exit widths
5 Exits should have a minimum separation of one-half the maximum overall
diagonal dimension of the building or area served Section 1004 2 4
6 Exits shall not pass through kitchens, store rooms, or spaces used for similar
purposes Section 1004 2 2
7 If exit signs are required, provide the following notes on the plans, per Section
1003282
a) Exit signs shall be located as necessary to clearly indicate the direction of
egress travel No point shall be more than 100 feet from the nearest
visible sign
b) Exit signs shall be readily visible from any direction of approach
8 Glazing in the following locations should be of safety glazing material in
accordance with Section 2406 4 for the glazing adjacent the new exit door and the
glass wall at the boardroom
City of Carlsbad 02-1O89
4/22/02
a) Fixed and sliding panels of sliding door assemblies and panels in swinging
doors other than wardrobe doors
b) Fixed or operable panels adjacent to a door where the nearest exposed
edge of the glazing is within a 24-inch arc of either vertical edge of the door
in a closed position And where the bottom exposed edge of the glazing is
less than 60 inches above the walking surface
9 Please provide complete plans for the attachment of the steel support beam,
lateral bracing and post attachment for the folding partition Specify manufacturer
and approval ICBO number
10 Please provide a section view of the glass wall partition Show
a) Specify manufacturer and approval ICBO number
b) Method of attaching top plates to structure (NOTE Top of partition must
be secured to roof or floor framing, unless suspended ceiling has been
designed for partition lateral load)
11 Please provide construction details for the new gypsum ceiling for the new
showers
12 Please provide evidence the controlled access hardware on door #15 is an
approved component of the egress system
13 Please revise the panel schedule to show the new HVAC loads
14 Please revise the electrical plans to show a roof mounted receptacle GFCI
protected within 25' of the new HVAC equipment
15 Please note or show a disabled accessible transaction counter that is at least 36"
long and no more than 28" to 34" high Section 1122B 4
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet, note or detail number,
calculation page, etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly
describe them and where they are located in the plans
Have changes been made to the plans not resulting from this correction list?
Please indicate
Yes a No a
City of Carlsbad O2-1O89
4/22/02
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation Thank you
City of Carlsbad O2-1089
4/22/O2
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad PLAN CHECK NO O2-1089
PREPARED BY Doug Moody DATE 4/22/02
BUILDING ADDRESS 2042 Corte Del Nogal Suite C
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN
BUILDING I! AREA II Valuation
PORTION (Sq Ft) Multiplier
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
3990
cb
City Valuation
By Ordinance
Reg
Mod
VALUE ($)
119,700
119,700
1994 UBC Building Permit Fee
1994 UBC Plan Check Fee
Type of Review
CH Repetitive Fee
Repeats
Complete Review
D Other
,—I Hourly
Structural Only
Hour*
Esgil Plan Review Fee
$60816
$395 30
$340 57
Comments
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB DATE
ADDRESS
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
(< $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENCINEER DATE
Docs/Misforms/Piannlng Engineering Approvals
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB 0
ADDRESS
DATE
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENGINEER DATE
Docs/Misforms/Plannmg Engineering Approvals
Carlsbad Fire Department 021089
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report 08/06/2002
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by
Name
Address
MANSOUR ARCH
5897 OBERLIN DR
City, State SAN DIEGO CA 92121
Plan Checker
Job Name Epigen X
Job# 021089
Job Address 2042 Corte Del Nogal
Bldg# CB021089
Ste orBldg No
1-71 Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
LJ Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st 2nd 3rd
021089 FDFile#
Other Agenny ID
Carfebad Fire Department 021089
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report Q4/16/2002
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by C
Name
Address
MANSOURARCH
5897 OBERLIN DR
City, State SAN DIEGO CA92121
Plan Checker
Job Name Epigen X
Job# 021089
Job Address 2042 Corte Del Nogal
Bldg# CB021089
Ste orBldg No
I I Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
\Z\ Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st 2nd 3rd
021089 FDFile#
Othftr Agenny ID
Requirements Category: Building Plan
Requirement Pending 0514 Provide Technical Report
To determine the acceptability of technologies, processes, products, facilities, materials and uses
attending the design, operation or use of a building or premises subject to the inspection of the
department, the Chief is authorized to require the owner or the person in possession or control of the
building or premises to provide, without charge to the jurisdiction, a technical opinion and report The
opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety
specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety
properties of the design, operation or use of the building or premises and the facilities and
appurtances situated thereon, to recommend necessary changes
Page 1 04/16/02
I LOVELACE
ENGINEERING
Structural Engineering Services
I
1
1n
I••
1
1
1
1
1
1
1
I••
1
1
STRUCTURAL CALCULATIONS
DATE: MAY 13, 2002
PROJECT: EPIGENX T I
2042 CORTE DEL NOGALSTE C
CARLSBAD, CA 92130
DESIGNER: MANSOUR ARCHITECTURAL CORP
5897 OBERLIN DR STE 1 1 1
S AN DIEGO, C A 62121
JOB: J02147
NOTE THESE CALCULATIONS ARE INVALID UNLESS BEARING A WET STAMP & SIGNATURE
JfP^w\//&/£? y\G>\\W w 1^ No 39734 ^ \Z\1
llS I Exp 12/31/05 Jrnlfi
6496 Weathers Place • Suite 200 • San Diego, California 92121-2958
i www lovelaceeng com • phone 858 535 9U1 fax 858535
JOB I T.X
LOVELACE
ENGINEERING, INC
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone (858) 535 9111 Fax (858) 535-1989
SHEET NO .OF.
CALCULATED BY
CHECKED BY .
SCALE _
Tl rVf DATE.
DATE.
i *•» 6-
I
GOVERNING CODE-.
CONCRETE:
MASONRY:
MORTAR:
GROUT:
REINFORCING STEEL:
STRUCTURAL STEEL:
WELDING:
SAWN LUMBER:
GLULAMS:
SOIL:
DESiGN CRDTERBA
UBC 1931
F'c = 2500 psi, NO SPECIAL INSPECTION REQ'D (U N O ;
ASTM C30, F'm= I&00 psf, NO SPECIAL INSPECTION REQ'D rU N O ;
ASTM C210, F'c = l800 psi, TYPE S
ASTM C416, F'c = 2000 psi
ASTM A6I5, Fy= 40ksi FOR *3 AND SMALLER
ASTM Afel5, Fy= 60ksi FOR *4 AND LARGER CU N O.)
ASTM A36, Fy= 36ksi CSTRUCTURAL SHAPES 4 PLATES;
ASTM A500, GRADE B, Fy= 4fcksi ^STRUCTURAL TUBING;
ASTM A53, GRADE B, Fy= 3&ksi ^STRUCTURAL PIPE;
E10 SERlES-TYP , E90 SERIES FOR A&I5 GRADE 60 REINFORCING BARS
SHOP WELDING TO BE DONE IN AN APPROVED FABRICATOR'S SHOP
FIELD WELDING TO HAVE CONTINUOUS SPECIAL INSPECT
DOUGLAS FIR LARCH, ALLOWABLE UNiT STRESSES AS PER UBC, CHAPTER 23
DOUGLAS FIR OR DOUGLAS FIR/HEM
24F-V4 FOR SIMPLE SPAN CONDITIONS
24F-VS FOR CANTILEVER CONDITION
ALLOWABLE BEARING PRESSURE
ACTIVE SOIL PRESSURE
ACTIVE SOIL PRESSUREfRESTRAlNED; =.
PASSIVE SOIL PRESSURE
SOIL DENSITY
COEFFICIENT OF FRICTION
pcf
pcf
^.EXISTING NATURAL SOIL PER UBC TABLE 18-l-A
SOILS REPORT BY
PROJECT NUMBER
DATED
SOIL CLASSIFICATION
LOVELACE
ENGINEERING SHEET NO
Structural Design and Title 24 Energy Analysis
6496 Weathers Place • Suite 200
San Diego California 92121
6195359111 Phone 619 535 1989 Fa*
CALCULATED BY .
CHECKED BY
SCALE
OF .(Co
T.rr DATE .
DATE .
f\o I OT-
D £>£.S<r<e..p-r/
F
- SV-e"
^ -2/3*1?,
- 2x4
?-o»f L,L
Roof P.i
E-fc AS
S/'OttO fi.. 8 ' o f.
/'-'f/ 3> a- 2-' * r 9'
D
BHJ
ira—IIL
UVA4
:a i
If-*—.k
P To
of
r-t fTi t r*i
vwoc
2 ^
82.
i 163 l£S
LOVELACE
ENGINEERING, INC
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego California 92121
Phone (858) 535-9111 Fax (619) 535-1989
JOB.
SHEET NO .
CALCULATED BY_
CHECKED BY
SCALE
OF
DATE,
DATE.
I
a ENGINEERING PESIGN
IAT*
(St » S<»N v
Fp =
i <
i
w
1 /»
(
Co. - 0. 44- Ma - o .4 4 > I i
r« -- i.o
-SO ( TAfrLt. U-o)
, O, L k~
J)
•*A-
LfeS
x /
1/NlT
: - f> I'M
D PRODUCT 207
JOB .
LOVELACE
ENGINEERING
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
SHEET NO
CALCULATED BY
CHECKED BY
I OF \^
DATE
DATE
SCALE
unit dimensions (50TJQ004-007)
*-» •. !srnSS««sx,—,—"—-<
9), ^Ea%^E^t,^^
f . »a ac * ^ C'86 '* 3 " c
^ cenrarca -mouiibi. lloorfrft (tern wood c( ens *«
^ —r f HEO 0 HOLE
THREADED. WIRE USE SIZES |MAX_1COMOUIT SIZE | . JS|2J2r
Sfllaci e«thgi V* 01 1'^ lor power depending on Y«(? t.tt
.-.V3L
LOVELACE
ENGINEERING
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
JOB
SHEET NO .
CALCULATED BY_
CHECKED BY
SCALE
DATE _
DATE.
LOVELACE
ENGINEERING, INC
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego California 92121
Phone (858) 535-9111 Fax (619) 535-1989
JOB_JQ-Z.TT7
SHEET NO .OF_
CALCULATED BY_
CHECKED BY
SCALE
DATE.
DATE.
AT
t
-T
676,
IX
OC- 7— 7/4').^t^'-o"
T*7'' I
-516
D PRODUCT 207
I
LOVELACE ENGINEERING INC
6496 WEATHERS PLACE STE 200
SAN DIEGO, CA 92121
Title EPIGENXTI
Dsgnr TPT
Description
Job* J02147
Date 11 HAM, 13 MAY 02
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Ph (858)535-9111
Fax (858)535-1989
Rev 510300
User KW 0601024 Vcr 5 1 3 22 Jun 1999 Win32(c) 1083 99 ENERCALC
Description (B-1) Calculation
Timber Member Information
Timber Section
Beam Width
Beam Depth
Le Unbraced Length
Timber Grade
Fb - Basic Allow
Fv - Basic Allow
Elastic Modulus
Load Duration Factor
Member Type
Repetitive Status
;' B-1 (door exten
6x12
in 5 500
in 11500
ft 800
Douglas Fir Larch
psi 1,3500
psi 85 0
ksi 1,6000
1 000
Sawn
No
Scope
Timber Beam & Joist
Calculations are designed
B-1 (door close
6x12
5500
11 500
800
Douglas Fir Larch
1,3500
850
1,6000
1 000
Sawn
No
7/K,
Page 1 I
s \data\enercalc\enercalc\02\i02147 ecw Calcu I
to 1997 NDS and 1997 UBC Requirements |
Center Span Data |
Span
Dead Load
Live Load
Point #1 DL
LL@x
Results
Mmax @ Center@x =
fb Actual
Fb Allowable
fv Actual
Fv Allowable
ft| 1600
#/ft 72 00
#/ft
Ibs
Ibs
ft
Ratio = 01703
m-k 27 65
ft 800
psi 228 1
psi 1,3393
Bending OK
psi 121
psi 85 0Shear OK
1600
57600
1 000
01507
647
1 02
534
1,3393
Bending OK
128
850Shear OK
._____™_™— —™_J
Reactions |(
@ Left End DL
LL
Max DL+LL
@ Right End DL
LL
Max DL+LL
Deflections
Center DL Defl
L/Defl Ratio
Center LL Defl
L/Defl Ratio
Center Total Defl
Location
L/Defl Ratio
Ibs: 57600
Ibs 0 00
Ibs 576 00
Ibs 576 00
Ibs 0 00
Ibs 576 00
in -0 095
2,0170
in 0 000
00
in -0 095
ft 8000
2,0170
54000
000
54000
3600
000
3600
-0015
13,1782
0000
00
-0015
6784
13,1782
_____ J
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
JOB .
LOVELACE
ENGINEERING SHEET NO .
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
CALCULATED BY _
CHECKED BY
SCALE
OF
DATE.
DATE.
'03 02 03 39p Mansour flrchitectural (858) 558-9231 P 2
iModernfolcT
PANEL DETAILS
PANEL DETAILS ARE NOT TO SCALE
Expandable Closure *:
90'Side Stack;
. Remote Expandable Closure -
'•'-,' •"'• Sir Side Stack " .
Remote Expandable Closure -
! ' Parallel Stack r i /
10-HOLD
SBERSIDEL
Remote Expandable Closure -
Offset Stack ' ;.
c
531
1 STACK DEPTHNO OF PANELS X 2 7t» * 2'
: Btfold Hinged Panel Closure .
. : ' • (Flat Slack) •''• ': "
V SIDEB
SiOEL
•ilold Expanoaple Closure
; (Fiat Stack) • ' •'•'''
[
-:""---^--w-*"?-*^;-.
^ SMK DEPTH ^NO OFPA«ELSX!W<7
V-.,,.
Remote Expandable Closine -
90* Side Stack (Flat Stack}
.. STACK DEPTH
uilold Expandable Closure
:"/ .' (Angle Stick) '
.Remote Expandable Closure •
Parallel Stack (Angle Stack)
E^Sj'S/SSj,
aJRj ( SgNO OF PANELS X 3 75* 2 ( ^
LOVELACEENGINEERING, INC
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone (858) 535 9111 Fax (858) 535-1989
SHEET NO .
CALCULATED BY _
CHECKED BY
SCALE
OF
DATE.
DATE.
NOTE TO FLANCHECKER; THIS SECTION CONTAINS THE FOLLOWING INFORMATION
CIF APPLICABLE TO THIS PROJECT; FOR YOUR USE IN CHECKING. THE PLANS
FOUNDATION AND FRAMING STRUCTURAL NOTES
NAILING SCHEDULE (TABLE 23-ll-B-U
SHEARNALL SCHEDULE
FOUNDATION PLAN PAD FOOTING SCHEDULES
FOUNDATION PLAN HOLDOHN SCHEDULES
SPECIAL INSPECTION SUMMARY LIST
STRUCTURAL DETAIL DRAWINGS
FOUNDATION PLAN FOOTING 4 HOLDOWN CALLOUTS
FRAMING PLANS RAFTER, HEADER, BEAM, POST 4
HARDWARE CALLOUTS
SHEARWALL LINE LOCATIONS
SHEARWALL CALLOUTS
JOB .
LOVELACE
ENGINEERING SHEET NO .
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
CALCULATED BY_
CHECKED BY
SCALE
OF_
DATE.
DATE.
EQUIPMENT PLATFORM
CN; 2x10 *2 JOIST (.& SPAN;
EA END OF PLATFORM,
ALIGN W/ EDGE OF PLATFORM •
\
(E)2X4 SUBPURLINS «
24" O C CREMOVE AS
r -(W U2I0 HANGER FROM
NEW JOIST TO CE; 4X12
PURLIN
-(E) 4X PURLIN BEYOND
ROOF FRAMING
TFS0I10
JOB .
LOVELACE
ENGINEERING SHEET NO n
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
CALCULATED BY _
CHECKED BY
SCALE
OF
DATE.
DATE.
-CM; EQUIPMENT PLATFORM
-CE;2X4 SUBPURLINS «
24" O C (REMOVE AS
REO.'D FOR DUCTING;
(E) 4X12 *l PURLIN—^
CDIRECTLY BELOWED6E OF PLATFORM;
ROOF FRAMING UPGRADE
TFS0II1
JOB
LOVELACE
ENGINEERING SHEET NO _OF.\(p
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
CALCULATED BY_
CHECKED BY
SCALE
DATE.
DATE.
EQUIPMENT PLATFORM
re; 2x4 SUBPURLINS « 24"
OC (CUT FOR (W2X\<Z»-
(W 2XI0 *] DIRECTLY UNDER
EDGE OF PLATFORM N/ (W
U2I0 HANGER TO (E) GLULAM
BM < CN; 2XI(Z> BEYOND
-REMOVE CEJ2X4
SUBPURLINS AS
REQUIRED FOR
DUCTING
ROOF FRAMING UPGRADE
TFS0II2
LOVELACE
ENGINEERING
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego California 92121
Phone 858 535 9111 Fax 858 5351989
JOB _
SHEET NO
CALCULATED BY _
CHECKED BY
SCALE
OF
DATE.
DATE.
*4 DOWELS « 12 "OC
AROUND PERIMETER
OF NEW FOOTING
CEPOXY 6" INTO EXIST'G
SLAB, 12" INTO FTG
ICBO *4345
FOOTING DETAIL
FF0I55
I LOVELACE
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
SHEET NO
CALCULATED BY .
CHECKED BY
SCALE
OF
DATE
DATE
' *
I
I
I
I
1
1
EXISTING 4x
"ROOF PURLIN
,_,,_ __ailfmp _..,-._!,,,,! L_,
ROOF
I
I
NEW UNISTRUT P2815
ADJUSTABLE BRACE
CONNECTOR W/ (2) 1/2" x
35" WD LAG BOLTS INTO
BEAM (TYP FOR ALL)
[SEE ARCH FOLDING
PARTITION
I DOOR ^ l(=:AM
I
I
1
I
I
I
JOB.
LOVELACE
ENGINEERING SHEET NO
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
CALCULATED BY_
CHECKED BY
SCALE
OF
DATE.
DATE.
10
I
I
I
I
I
I
1
1
I
I
1
LOVELACE
ENGINEERING SHEETNO ,,|(p
Structural Engineering Services
6496 Weathers Place • Suite 200
San Diego, California 92121
Phone 858 535 9111 Fax 858 5351989
CALCULATED BY_
CHECKED BY
SCALE _
OF
DATE.
DATE.
<
O
O
OO2 LL
2 5
or
-i^t^^y
< $ D
-- LU <H- C/3 CC<cr«
"^ LU (.9*?a
crcc cr
ccO
LU
£ cj
O w> LU
i£
liSS^p
Q- LU C/3 O Q. m
— ^.d AH ^^. ••** ^^> I _^
mO-LUU-XXOCQ
t-
rr-
/M
J
-T|I^ V
fXr
Ao
^
^4-
A6>^^i
'\•c
cr
t
Oo.cr Q.u. <
O
ofcI- <
c
-^m
^
l"
^
^f-P
hID
-5
^X
3
/^Q
<s-
S A)
g ?Q <ri^r
X
oU-
% Q
vj
^^\ ^<J f\)r*
) ^
T ^
^^
'^M:
^,.V
t^
o \ =*
^v^
-^
r%<^