HomeMy WebLinkAbout2042 CORTE DEL NOGAL; B; CB060077; Permit03-06-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB060077 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2042 CORTE DEL NOGAL CBAD St B Tl Sub Type 2130610500 Lot# $87,500 00 Construction Type INDUST 0 NEW QUALIGEN-NOW IN STE A-EXPAND IN TO STE B-2500 SF WHOUSE TO BATHROOMS, Applicant ICS PACIFIC BUILDERS SUITE A 7440 TRADE ST 92121 858-578-7500 Owner BOND RANCH Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* ISSUED 01/09/2006 RMA 03/06/2006 03/06/2006 8530 LA MESA BLVD #300 LA MESA CA 91941 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $500 36 Meter Size $0 00 Add'l Reel Water Con Fee $325 23 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1838 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $000 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $0 00 $000 $000 $000 $000 $000 $000 $000 $000 $000 $111 00 $3500 $2400 $000 $000 $000 $000 $1,01397 Total Fees $1,013 97 Total Payments To Date $1,01397 Balance Due $000 BUILDING PLANS -J/.IN STORAGE ATTACHED Inspector FINAL APPRpVAL Date J Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications reservations, or other exactions hereafter collectively referred to as "fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION V ' , CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1. PROJECT INFORMATION 0600901-2 0025 01/09/2006 001 11 . PLAN CHECK NO £$ f) () @O 7 J~ t r^j EST VAL Plan Ck Deposit Validated By Date / / 4 / f)L( (£.«-- S3 Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use Proposed Use CONTACf PERSON {if different'appiicarit)" Name !3 . APPLICANT Address City Contractor O Agent for Contractor ;O Owner [1] Agent for Owner State/ZiiP'. Telephone # Fax #ate/Zii. "' Name 4 '""" PROPERTY OWNER :: Address City State/Zip Telephone j Address City State/Zip Telephone #Name 5 ^CONTRACTOR - COMPANY NAME Jiff" jjff '•'" ,j:a=:h;i :"" : *\ " . .„.,»,: (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollais ($5001)' * Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # 6 WORKERS' COMPENSATION ddress City State/Zip Telephone Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued *S2|_ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is 'issued My worker's compensation insurance carrier and policy number are . ___ . £-L)<O (A _ Policy No I I 0 D *"\ \ *T>Insurance Company Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) 0 CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE _ DATE _ iiP OWNER-BUILDER; DECLARATION „ .. ' : : :, - ... -.;.v"" ^P?1-- ,..::..::...,. i:|:. •• 1 hereby affirm that I am exempt from the Contractor s License Law for the following reason [~1 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) 0 IF as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractors License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) [~l I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES I~]NO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) __ 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) _ __ __ ____ PROPERTY OWNER SIGNATURE DATE COMPLETEiTHlS SECTIONLFOR NON-RESIDENTIAL BUILDING PERMITS ONLYlt ^S:S Mis / T 't- is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management <md prevention program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' f~l YES Q<NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district oj,air quality management district7 L~3 ^ES X.r*1^^Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES ^Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEE TING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT i8vj:CONSTRUCTION LENDING AGENCY %jS . "' ' •%;;.- jy::.::; :iy;;:. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME LENDER'S ADDRESS 9. APPLICANT CERTIFICATIONr , .,^ ...,;,;:' ...«*•'''! • ' ";l.:,-:.,;- "-^^ '"'"; I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued byJj3e_buildinaJ3theta[ under thejprovisioj3&-of"this Code shalj^expire by limitation and become null and void if the building or work authorized by such permit is not cpfnfnencedkMm 180 da\s from thAjateof such permit or ifjhe^uildmg or work authorized by such permit is suspended or abandoned at any time after the work is cprfmienced fgjisyperiod of 1 fjp days-JEection 106 4 4 Uniffttm-Eiuilding Code) dt' n-bfrAPPLICANT'S SIGNATURE DATE VHITE File YELLOW Applicant PINK Finance cfnoicuitM final Building Inspection Dept Building Engineering Planning CMWD St Lite Plan Check # Permit* CB060077 Project Name QUALIGEN-NOW IN STE A-EXPAND IN TO STE B-2500 SF WHOUSE TO BATHROOMS, MAN 2042 CORTE DEL NOGAL #B Lot JUNIOR Phone 8585187990 CA ^ Water Dist CA Date Permit Type Sub Type 04/20/2006 Tl INDUST Address Contact Person Sewer Dist Inspected By Inspected By Inspected By Date Inspected Date Inspected Date Inspected 2-& , /0(cy Approved Approved Approved Disapproved Disapproved Disapproved Comments City of Carlsbad Bldg Inspection Request For 05/03/2006 Permit* CB060077 Title QUALIGEN-NOW IN STE A-EXPAND Inspector Assignment TP Description IN TO STE B-2500 SF WHOUSE TO BATHROOMS, MANUFACT.WORK/COPY ROOM & WAREHOUSE Sub Type INDUST 2042 CORTE DEL NOGAL B Lot 0 Type Tl Job Address Suite Location OWNER BOND RANCH Owner BOND RANCH Remarks FINAL PANEL INSPECTION Total Time Phone 8585 Inspector Requested By JIM Entered By JANEAN CD Description 39 Final Electrical Act Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# Date 04/20/2006 04/07/2006 04/07/2006 04/07/2006 04/07/2006 03/27/2006 03/21/2006 03/21/2006 03/21/2006 03/21/2006 03/08/2006 03/08/2006 03/08/2006 03/08/2006 Inspection History Description 89 14 24 34 44 17 14 24 34 44 14 21 24 34 Final Combo Frame/Steel/Boltmg/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Boltmg/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Boltmg/Welding Underground/Under Floor Rough/Topout Rough Electric Act CO PA we PA PA AP AP AP AP we NR AP AP NR Insp TP TP TP TP TP TP TP TP TP TP PD PD PD PD Comments SEE CARD SEE CARD OK TO PLACE BORDER TILE WALLS ONLY WALLS WALLS ' EsGii Corporation In Partnership with government for tBmftfing Safety DATE 3/3/06 a APPLICANT JURISDICTION City of Carlsbad a FILE PLAN CHECK NO 06-0077 SET III PROJECT ADDRESS 2042 Corte Del Nogal Suite B PROJECT NAME Qualigen - TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 2/24/06 tmsmtldot 9320 Chesapeake Drive, Suite 208 * San Djego, California 92123 + (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (Building Safety DATE 2/14/06 a APPLICANT JURISDICTION City of Carlsbad 3~PTATTREVIEWER G FILE PLAN CHECK NO 06-0077 SET II PROJECT ADDRESS 2042 Corte Del Nogal Suite B PROJECT NAME Qualigen - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X) The applicant's copy of the check list has been sent to ICS Builders / Edward Fernandes 4885 Ronson Court Suite E, San Diego, CA 92111 Esgil Corporation staff did not advise the applicant that the plan check has been completed X3 Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Edward Fernandes Telephones 858-518-8259 Date contacted 2)v>\l<!'ip(by ^ Fax # & - c9 ~/<g> - <^) | Mail Telephone / Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 2/6/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego California 92123 * (858)560-1468 * Fax (858) 560-1576 City of Carlsbad O6-OO77 2/14/O6 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO O6-0077 PROJECT ADDRESS 2O42 Corte Del Nogal Suite B SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 2/6/06 2/14/06 REVIEWED BY Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo City of Carlsbad O6-0077 2/14/06 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code The plans are still not signed. 3 A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 3-D arid 3-E possible The building official requires a technical report to identify and develop methods of protection from hazardous materials Section 307 1 6 No response 4 Provide a section view of the new hard-lid ceiling Show No response. a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" b) Method of attaching top to the structure and lateral bracing c) Wall sheathing material and details of attachment (size and spacing of fasteners) d) Show height of the hard-lid ceiling from floor, hard-lid ceiling to roof framing or floor framing 8 Please detail the on the plans lighting control panel circuiting No response. 10 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 700# rooftop air handler unit Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code No response City of Carlsbad O6-0077 2/14/06 11 Please have the principle designer check the appropriate box(s) in the Statement of Compliance System Acceptance section of the MECH-1and LTG-1-C documents Forms not provided or completed and imprinted. 15 Please clarify the water line plans it appears the urinal is connected to the hot water system9 No response 16 Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc No response To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGil Corporation In Partnership -with government for Quitting Safety DATE 1/19/O6 a JURISDICTION City of Carlsbad a PLAN REVIEWEER a FILE PLAN CHECK NO O6-OO77 SET I PROJECT ADDRESS 2042 Corte Del Nogal Suite B PROJECT NAME Qualigen - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X3 The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to ICS Builders / Edward Fernandes 4885 Ronson Court Suite E, San Diego, CA 92111 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Edward Fernandes Telephone # 858-518-8259 Date contacted || M|M (by £\) Fax # <&><& & "7 & ~ °/ Mail Telephone *^ Fax In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB E] EJ D PC 1/10/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560 1576 City of Carlsbad O6-OO77 1/19/O6 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O6-O077 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 1/9/06 DATE INITIAL PLAN REVIEW COMPLETED 1/19/06 JURISDICTION City of Carlsbad USE Warehouse/ Manufacturing ACTUAL AREA 1835sf STORIES 1 HEIGHT OCCUPANT LOAD 9 DATE PLANS RECEIVED BY ESGIL CORPORATION 1/10/06 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforwdo! City of Carlsbad O6-O077 1/19/06 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted irrone of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbing/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt 'the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC 3 A complete description of the activities and processes that will occur in this tenant space should be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification m Tables 3-D and 3-E possible The building official requires a technical report to identify and develop methods of protection from hazardous materials Section 307 1 6 4 Provide a section view of the new hard-lid ceiling Show a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" b) Method of attaching top to the structure and lateral bracing c) Wall sheathing material and details of attachment (size and spacing of fasteners) d) Show height of the hard-lid ceiling from floor, hard-lid ceiling to roof framing or floor framing 5 Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) Show in this analysis the occupant load of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths City of Carlsbad O6-OO77 1/19/06 6 Exits shall not pass through kitchens, store rooms, or spaces used for similar purposes Section 1004 2 2 7 Please provide a roof plan showing the new roof mounted equipment and a service receptacle located less than 25' from the new equipment and GFCI protected 8 Please detail the on the plans lighting control panel circuiting 9 Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 10 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 700# rooftop air handler unit Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code 11 Please have the principle designer check the appropriate box in the Statement of Compliance section of the PERF-1-C energy document and sign the appropriate portion 12 Please have the principle designer check the appropriate box(s) in the Stalement of Compliance System Acceptance section of the MECH-1and LTG-1-C documents 13 Please complete the ENV mandatory measures imprinted on the plans (sheet M- 2) 14 Please correct the energy design provided and revise the wall details to show compliance 1 Demising wall insulation The insulation installed at demising walls of non- residential buildings shall have an R-13 value (118(f)) 15 Please clarify the water line plans it appears the urinal is connected to the hot water system'? 16 When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features 17 Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space Please provide detailed plans of the path of travel, indicate slope and width, any City of Carlsbad O6-0077 1/19/06 pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes U No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad 06-OO77 1/19/06 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O6-OO77 PREPARED BY Doug Moody DATE 1/19/06 BUILDING ADDRESS 2042 Corte Del Nogal Suite B BUILDING OCCUPANCY B/S1/Fl TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 2500 cb RIHn Pprmif FPP hv OrHmanrp '" • V Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 87,500 87,500 $491 36 Plan Check Fee by Ordinance Type of Review l~l Repetitive Fee ~~^i Repeats Complete Review D Other ,—I Hourly D Structural Only Hour* Esgil Plan Review Fee $31938 $275 16 Comments Sheet 1 of 1 macvalue doc PLANNlNC/ENCINf ERING APPROVALS PERMIT NUMBER CB ADDRESS RESIDENTIAL RESIDENTIAL ADDITION^MINOR «$10,000.00) DATE TENANT IMPROVEMENT MOREAIC CARSBAD COMPANY VILLAGE FAIRE COMPLETE OFFICEBilllDIIMG' OTHER PLANNER DAT? ENGINEER DATE Plan Check No Planner Erin Endres PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Address Phone (760)602-4625 APN _ Type of Project & Use Zoning h-Al General Plan Net Project Density.DU/AC Facilities Management Zone _.5" CFD (m/«fut))#_Date of participation Remaining net dev acres. Circle One (For non-residential development Type of land used created by this permit ) Legend. ^ Item Complete I Environmental Review Required: DATE OF COMPLETION Item Incomplete - Needs your action YES Npx<_ TYPE Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval Discretionary Action Required* APPROVAL/PESO NO PROJECT NO YES NOX" TYPE DATE OTHER RELATED CASES Compliance with conditions or approval? If not, state conditions which require action Conditions of Approval NO Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES CA Coastal Commission Authority? YES If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) _ Coastal Permit Determination Form already completed? If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # _ YES NO fX Follow-Up Actions 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed Inclusionary Housing Fee required. YES NO^3c~ (Effective date of Inclusionary Housing Ordinance - May 21,1993) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 l3 Site Plan 1 Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) 2 Provide legal description of property and assessor's parcel number Policy 44- Neighborhood Architectural Design Guidelines 1 Applicability YES _ NO _ 2 Project complies YES _ NO _ Zoning: 1 Setbacks Front Interior Side Street Side Rear Top of slope Required Required. Required. Required. Required. 2 Accessory structure setbacks Front Required Interior Side Required Street Side Required. Rear Required. Structure separation Required. Shown. Shown Shown. Shown Shown Shown Shown Shown Shown Shown 3 Lot Coverage 4 Height Required Required. Spares Required Shown Shown Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Cor provided and, Correction #1 - Please show on sheet 1 the total number of parking spaces Copfeotion /f2n site for each use per Chapter 21 44 willi II us UUllQihg perrflll OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Carlsbad Fire Department Plan Review Requirements Category TI, ENDUST Date of Report 01-23-2006 Reviewed by Name Address i Permit # CB060077 Job Name QUALIGEN-NOW IN STE A-EXPAND Job Address 2042 CORTE DEL NOGAL CBAD St B INCOMPLETE Tho item-you have submitted for review is incomplete A- adequately conduet a re-view to dotormmo compliance with tho applicable? oodeo and/or ctandardo Pleaoe review carefully all comments attached. Please resubmit the necessaityplans an^/or specifications, with changes "clouded" to thio offioo for review and approval Conditions; Cond CON0001030 [MET] APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW Entry 01/23/2006 By gr Action AP ( , 02/A7/2006 12 21 FAX 7606039476 QUALIGEN EXEC 0001 Qualigen At tht Point of Carf February 16,2006 Edward Femandes President ICS Pacific Builders Inc 4885 Ronson Court, Suite E SanDicgo, CA92111 Dear Edward, Per the icquest of the City of Carlsbad Building Department, the following activities will be conducted in the new space you are developing on Qualigen's behalf at 2042 Corte del Nogal, Cailsbad, CA 92011 -General warehouse and storage of shipping and packaging supplier and non-hazardous manufacturing materials -Dry storage nf medical equipment for shipment to customers -Cold storage of non-hazardous reagent test kits for shipment to customers -Assembly of medical equipment products -Men's locker room and rcstroom facility -Women's locker loom and rcstroom facility -Janitors closet for storage of paper supplies and non-hazardous cleaning supplies Computers for manufacturing data entry In addition, we have reviewed the City of Carlsbad hazardous materials tables (Table 3- D 1 and Table 3-E) None of the materials listed will be stored in this new space Please contact me if you have any questions or require additional information Best icgards, Paul A Rostnack President and CEO 2042 Corte rlPlNoqal, Suite B Carlsbad, CA 92011 Tel 877 709 2169 Fa* 760 918 912/ www qualigenlnc com "f^tij 1 FAX NO. 760 602 8558 P, 02 TABLE 3-D TABLE 3-D-EXEMPT AMOUNTS OF HAZARDOUS MATERIALS PRESENTING A PHYSICAL HAZARDMAXIMUM QUANTITIES PER CONTROL AREA4 When two units are olven, values within parentheses are In cubic fast (cu. n) or pounds (Ibs.) 'cONDmOK MMtrlil 1 1 Combmnble 1 2 Combutubk Tiber (loou) (bilcd) ) 3 Cryogenic, Oammabta or oxidizing 2 1 Explosives J 1 Flammablo Joltd 3 2 Flammable gas(gaseous) (liquefied) 3 3 Mammabla Cbmbmanon 1-A, I 0. I Cls 4 1 Oigaaic Bcroxidt, unclueuied dttonatablc 4 2 Organic peroxide 4 3 Oxidizer (gaicouf)®*^ (ItQUCflsd)^® 5 1 Pyrophonc 6 1 Unstable (reacbvc) 7 1 Water wac*iv» CIIM 11 HI-A III-B M IB I-C I II HI IV V 4 316 2 1 4 3 2 1 3 2 1 ETOHAOE' (CttH) KftWJJfer NA. NA- NA (100)(»,ooo) NA 110.13 125' I"" NA NA NA NA. NA. NA ,*u 5*,iiT 50M<^ lZ5»,to 5006,10 NU ~ jIWI " • IdMo rio*,'" 4,000*.fl> NA NA. 4ku,li jto,Ii 54.10 id*'10 NU JS.10 jfl»'lB 125'Wl (Uaj »s TH fcr L •f 12010 330'° J3^6ol«,ft NANA. 45 (l)ft " NA MAo 30>^ 60"^ 90"* IM» /j\WV,ll /<fyS)d Jsof" (12S^1D (5QO)*'11* NU ^jjl^il (JO^-1^ (250)*,^ (4^)00)6^ NA15 (4)^0.1^ (l)To,ft (5)*,'° (SO)4-10 NU (Sf"> Qtif<w (12S)10'" Cy Pi x tfilttfrr i»r NA NA. NA NANA NA NA NA 7NA10 NA. NA NA. NA NA " NA. NA. NA NA. NA NX ^ NA NA. NA. 1,500 5(jlo,K I0lo-lf SO*'19 2JO«,i« VSO6'1"1 NA. NA. NA usEi-CLOtiED syrreio (cu.ru X BJ12J5 for NA NA. NA (« NA 1/4*7 14 NANA NA NA NA NA V V SO6 12S& 500^ NU '/411 2* 250*^ 4/100* NA NA \ti l/4« 1s 5# ^ NU 3s 50* 12S" UVffi*. xlTWBlcL k« 120 330 13.2IX)11 NA NA 45 P/312 NA. ^»30 n 60 90 120 ('/<)« (If (50? (125)^ (500)» NL (\«)iz (if (250)* f4,000)r NA 15 (ifi (^/4)*Z (I)* (so? NU ^ (S? (»)* (125)" c»Cu.fi. XMJUfbrnt* NA NA NA. NA NA NA. NA NA w NA NA NA ^ NA NA NA NA NA 1 N A NA NA NA NA NA 1,500 NA. l(flO,ll 2«>,n 10'.'0 2SQ6^° NU NA NA. NA US6»-OPEM SYSTEMS (0! FC| "*1»T1'" NA NA NA. (20)(200) NA. V1 14 NANA NA NA NA. NA i,,n l* 10* 25* 100* NU111 v;« 2* 50* 1,000* NA NA 0 Vi11 I6 10s NU 1" 10* fe« UOIlM Clllorw xtMSMfor 30 80 3,300" NA NA 10 (V*)" NA NA 10 IS 20 30 ,(S/4)U (I}4 1 I'lO? (25)* (itW)6 NU (V<)1J I?)6 (')O)4 (IjOOO)*1 NANA 0 (*/«)n (1)* (JO)4 NU (If (10)'' (2S)*r N A<—Not applicable N U—Not limited, •cooirol aroai shaJI be separated bom each otter by not leu Inaa a one-hour flre-nautlM occupancy separation The aumter of caniool areas wilhin a buildingi»ed /or retail or wboIftMje aalci aball pal exceed two Tb« qumber or conlrol Una in bufldlagi wild olher u«a ihaU not exceed foui Sec Section 204fThc aggregate quantity ID tua and aloraje ihall not axoced the quanllly luted for atorage 'The jg^reeito quantity of aonflatnmabfe to) Id and nooflinimablear aoncombu«nb(e liquid baunioiia ntateruU wiihm sairygle conliol aitt of Group M Ocotpiin ciea wed for reufl gales may ctoccd tt« ctemfl amounts when wch areas arc in compliance with Ihe Piw Code, *Tbe quanbnet of alcoholic beverages in retail ailM uses an unlimited provided the liquid* arc packaged u individual containers not exceeding 4 tilers.Toe quantifies of medJoocs, foodgtufb aad eounMia containing not more taui SO peraat of voluipe of w»let-muicibU Uqutda and wilk Ibe remainder of thesolutions not being Qammablc kj retail tales or storage oocupanclea are unlimtled when packaged In individual oonialaca not eiceedtej 4 ((ten'For aeiosob, tte the Fun Code. °Qu wu<(« may b« wcieued 100 percent inapriiUettd buildisga Wben Footnote 10 »!» appliei, the ucreate for botb footaolci may be apifad fForSFM] Tilt kltmi buiUuigj7For sion^c and ute of flunniablo and conbuslible dquKte lo Oroupt A. B, E, F, H, I, M. R, S and U Occupmcws, see Secbona 303 8,304.8,305 8,306 8,307 11innmgh 307 i 5,308 8,309 8,310 12, Jll 8 and 312 4*For wholesale and reud Mica gsc, alio KB ibe Puc Qxle. ay application of any quantity offlamnablt or combustible liquids shall be conducted « ut fortb in tbe Fire Code aiHii«» m»> be increaiid 100 peraeM whan stored in approved ttof»je abincls, gu cabtnels or cxhaosttd ewlN'o^ny Pootootc 6 also applitj, ifie increase for both foolaolu may be applied "The quanl>tie« permitted in a spnnklcred buildwg are not limited OCTOBER 1,2toJ ERRATA wlNures as speulied in ibe Fu» Code Wben t-4as CL »CL REB-ll-2006THU01:14Pt1CITYOFCARSLBAD TABLE 3^0,1 P. 03FAX NO. 760 602 8558 2001 CALIFORNIA BUILDING CODE FOOTNOTES TO TABLE 3-[V-(Con1lnu90) '^ernilned in ipnokleitd BaUdmgs only None u allowed m umpiuUeied tunldine* "One pound of black sporting powder and 20 pounds f9 kg) of imolrtless pooler «rt permitted in sprinklmd orunspluiklcttd buildingi "SetaefioitlOH of Divisions 2 *nd 3 in Section 307 t15Canl»u>in* not more thin (he <«m(H amount* of Gwi 1-A, Ctaa I-B or CtaM I-C fl»mm»blc liquidi E I "A muununi quiouiy of 200 pound* (90 7 kg) of toltd or 20 gallons (75 7 L) of liquid Class 3 oxidizcn may te permitted wfecn sucb miwhils we aecttsaiyf torn4bircntiicepurpo»»ora|Kralianof«qutpmcn<amtfbnliulh6Pv*U>d« AC ftACAC ft ACA ft 1C c ft c A §A ft ft ft ft A A TABL£ 3-O 1 /For SFftQ-eXQWr AMOUMT5 Of HAZARDOUS MATeflWLS, LIQUIDS AMD CHEMICALS PRESENTING A PHY&CAL HAZARD BASIC OUANTmES PER LABORATORY SUfTE' Wbm two on/to ar» piuwv value* ttffMflpww>t/i«Ms wo //> eubfc f**» (Cu. «.> expounds (Ltm) coHomoN MATTAMl V 7 Combustible liquid J 2 Combuitlklf due toi/f 000c«y> J 3 Comhutlbleflbtr (loose) 1 4 Cryogenic, flammable or otHHtlng 2I£xplottva 31 Flammable tokd 3 2 Flammable got (etutotu) (Juiutflea) 3 3 Flammable IqtiJ ConblnaUonf-A.l-B.l-C 4 i Ofgnntiperwadt, Hncl&Wifled dttonatablt 4 2 Organic ptraxide 430* Jilt, 4 4 OxUaer—Oai (fott&u) (llqutfied) 1 1 Pynpliortc 6.1 Unttabtc (mettvt) 71 Kterd*** CLAM 11 7/M HI-B l-A l-f l-C 1aIttIV V 43 2I 4321 3 21 STOHAOe (Cvft) — 1 — —, (100)(1,000) I1 12S* — — — — —fl 12S*SOOAU.4ISO* 1,000* — 4* J J ffif 120* 330* mad*_ — 45 (I)2 — IS1 30f 60* Jjfll 730* WZ 1M ;7' (V*MM' CM — — —__ ^ —~- 7SI? — — ——~** — — i#* SO2 to* SO1 216* 7SO* — U3E-&OSIP SYSTfUa ^«r — —— ; tfoo; (1,000) — lk 25 __m_ — — — —% I2S 500 2 2SO 1,000 ~ 1 IX 5 SO125 LWUW(town*(UU 120 330 13,200 — . — 45 i'M \ — 7s' 30 60 90 120 Cfi) (125) 8? (250) (1,000) if3 (i) (w00)(hs) & Ou — — — — -j. — — — 7SO* — — — —^ — - ,,500* IP 230* 750* — use—opeHsrsrEvs SoWUo- — — —, <$ — *<* 25 — — — — —'* 10 25100 3SO200 ^^ 0 110 25 102f (U»J 30 80 1 3300 __ — 10 (fM — - to IS 20 30r;/w ; fl — 0 ($ (10) 05) §) <SSi — — —_ — — — — _ — — — —-" — — — 0 000 0 ^™ 1JL. —Not latittd. 'AbbaratorrniKbaJfact*pvlO,OMtqwrefet(91Pai*)batw<tcdbyr&lcisfaria<>iie^rfar<^tK& amowito ofhtuardout matoriais may be tloreJ, duptiucJ, handled or ttwi Vp througk Ac third far tndtom through ihc first btutmtitt floor, At quantify inftistabk^UoprdpFcHir^ffiHBrttbAJbortoitflkettarterttrurdbwmfrit^rlMlyuaMW^HfciHraufh lOih floor and t>clo» Oielfiird batemefit floor level quantity ftiallbe reduced to SO percent aflha table *Qnanitlu* nay bt Increased 100 percent when Kartd in approved aJvtiulnl g<u tabimu, lsha(a[t<t tnclotuns or fume hoods OCTQOEB1 ^FEB-16-2008 THU 01:15 PM CITY OF CARSLBAD FAX NO, 760 602 8558 P, 04 J001 CALIFORNIA BUILDING CODE TABLE 3-E TABLE 3-E—EXEMPT AMOUNTS OF HAZARDOUS MATERIALS PRESENTING A HEALTH HAZARD MAXIMUM QUANTITIES PER CONTROL AREA' * Whan two units art glv*n, viluei within pertnthsafts are in pound* (lb») MATgfllAL 1 Corrosives.10 2 Highly toxii.k7 3 Iriiuntt4 4 So/mmer** S Other health ha»«li' 6 Tbxics' STORAGE1 Solid LM « • • x 0 44M far kg 5,000 10 NL NL NL 500 OJ&M (Lb*,) * me to.L X 0.4KM Mr kg 500 (10) NL NL NL L_ (»0) OMcu n» x DUB form9 810* 20" 8101111 810*." 810&.» 810* USE3— CLOSED SYSTEMS SellitLbi" K 0 M» (Of Kg 5,000 10 NL NL NL 500 Ut,uld0<ll0n*»(1.04.) x 3 785 for IX 045Mforkg 500 (10) NL NL NL (500) Go. CU «.» x a <a$ (or m3 BIO* 20« 810' J1 810*." 810'" 810" USe^-OPEN SYSTEMS »_J x 044Mtorka 1,000 j 3 5,000" 5,000" 5 000" 125 UquldOillon**'(lt») x J 7M fa» L x 0 <!6]« hu Kg 100 (3) iOO" 500" 500" (125) Ii i NL = Not limited | 'Control urea] shall be Mpimed from each other by noi less than * line-hour fire resistive occupancy separation The number of control area* within ,1 building used tor retail at wholesjje sales shall noi exceed two. The number of ccnirol areas in buildmgfc w|tri other useb ^hall not exceed four Set Section 204 *The quaniinet of medicine*, foodnuffi and cosmetics, containing not more Ihftn 50 percent by volume of water mincible liquids and with the remainder of Ine 'The aggregate quantity in use ind storage shall not exceed the quantity Hiud (or iloiage ''The aggtegaU Quantity of rwnflammnblt Solid and nonflimmablc or noncombuMiblcliquid health hnz»«l mat«nalj within > single control arts of Group M Occu- panciei uied (fit reiail sales may exceed th« exempt amounts *hen such afcus ire m compliance with th« Fire Code sQuunimc:> may be mcrcistd 100 percent in spnnklcred buildings When Footnote 6 alio applies, ihe mcreut for both footnotes may b« jppli«d ''QuaRliiiei muy be increased 100 pcrcinl when stored in approved storage ctbmeli, g«i cubinefi or cnh«i/sle<j cncloiurci U specified m the F\K Cade Wlicn footnoie 5 also applies, the mcreue for both fooinoies may be applied7For special provision!, ice ihe Fire Code ^Permitted only when stored in approved oxnuusied JJM cabmen, exhaubted tncloiurcs 01 fucro hood^t 'inilBnU, ^ensilizers *nd other health hazards do not include commonly gtcd building mntcnals and consumer produce ih»l .ire not otherwise regulated by ihn code10For italioiuiy lead acid baiitry systemi, see the Pne Code "The quintities ullowed m a ipnrtHercd building ate noi limiled when exhaust vcntllftuon is ptovidtd m acconlance wiih Ihe Fire Coda See T.ible 8001 15 U, Footnote 12 License Detail Page 1 of 2 License Detail Contractor License # 799325 CALIFORNIA CONTRACTORS STATE LICEN DISCLAIMER A license status check provides information taken from the CSLB license data base Before on this information, you should be aware of the following limitations • CSLB complaint disclosure is restricted by law (B&P 7124J3) If this entity is subject tc complaint disclosure, a link for complaint disclosure will appear below Click on the IIP button to obtain complaint and/or legal action information • Per B&P 7071 17, only construction related civil judgments reported to the CSLB are disclosed • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration • Due to workload, there may be relevant information that has not yet been enteied ont Board's license data base Extract Date 01/09/2006 * * * Business Information * * * I C S PACIFIC BUILDERS 4885 RONSON COURT STE E SAN DIEGO, CA 92111 Business Phone Number (858) 247-8540 Entity Sole Ownership Issue Date 09/14/2001 Expire Date 09/30/2007 * * * License Status * * * This license is current and active All information below should be reviewed. * * *Classifications * * * iCIass, Description i IB !GENERAL BUJLDING CONTRACTOR! * * *Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 1029775 in the arr $10,000 with the bonding company http //www2 cslb ca gov/CSLB_LIBRARY/License+Detail asp 01/09/2006 License Detail Page 2 of 2 * * * SURETVLCQMPANY_QF THJEPACIFLC. Effective Date 01/01/2004 Contractor's Bonding History Workers Compensation Information * * * This license has workers compensation insurance with the STATE COMPENSATION INSURANGE FUND Policy Number 1780415 Effective Date 04/13/2004 Expire Date 04/01/2006 Workers Compensation History Personnel listed on this license (current or disassociated) are listed on other licet Personnel List. Other Licenses License Number Request Contractor Name Request Personnel Name Request Salesperson Request I Salesperson Name Requestlest [ © 2005 State of California Conditions of Use Privacy Policy http //www2 cslb ca gov/CSLB_LIBRARY/License+Detail asp 01/09/2006 Feb 22 06 07:19p Mobaaed Consulting Group 858 586 7845 p. 2 JOB. MCG MOBAYED CONSULTING GROUP CONSULTING STRUCTURAL ENGINEERS 7940 SILVERTON AVENUE STE 208 SANDEGO CALIFORNIA 92126 TEL [858] 586-7855 FAX (858) 586-7845 SHEET NO . CALCULATED DY_ CHECKED BY SCALE OF DATE. DATE- Feb 22 06 07:20p Mobaaed Consulting Group 858 586 7845 MOBAYED CONSULTING GROUP p. 4 MCC SHEET NO. CONSULTING STRUCTURAL ENGINEERS 7940 SILVERTON AVENUE STE 208 SAN DIEGO CALIFORNIA 921 26 Ta (853) 586-7855 FAX 1858) 586 7845 CALCULATED BY. CHECKED BY SCALE OF DATE. DATE." = ;-w 5*3} :i -.. Feb 22 06 07: 19p Mobayed Consulting Group 858 586 7845 p. 3 MCQ MQBAYED CONSULTING GROUP CONSULTING STRUCTURAL ENGINEERS 794Q SILVEHTDN AVENUE STE 208 SAN DIEGO CALIFORNIA 92126 TEL (8581586-7855 FAX (858)5867645 SHEET NO . CALCULATED 6V_ CHECKED BV SCALE : OF. DATE DATE r ro M)8J(® (#"« c Febv22 06 07:20p Mobased Consulting Group 858 586 7845 r T P.S STRUCTURAL CALCULATIONS For QUALIGEN ROOF TOP MECH. UNIT Prepared For ICS PACIFIC BUILDERS, Inc. Prepared By. MOBAYED CONSULTING GROUP 7940 Silverton Avenue, Suite 208 San Diego, CA 92126 (858) 586-7855 * FAX(858) 586-7845 PROJECT NO.: 06010-1.10 DATE ISSUED. 02/22/2006 REVISION DATES. IVIC3G Feb .22 06 07:20p Mobaaed Consulting Group 858 586 7845t > MCG MOBAYED CONSULTING GROUP CONSULTING STRUCTURAL ENGINEERS 79-10 SILVERTON AVENUE. 5TE 208 SAN DIEGO CALIFORNIA 92126 TEL (B58J 536-7855 FAX (858) 586-7845 SHEET NO CALCULATED BY_ CHECKED BY _ SCALE _ OF DATE. __ DATE Q (\ ZI1H3' LL ^ ] I i -;../v v S: * » <=. <£ PDOOICIIM I |Sng» SHB) JIK.I IPMMI Feb 22 06 O7:21p Mobaaed Consulting Group 858 58B 7845 MOBAYED CONSULTING GROUPMCGCONSULTING STRUCTURAL ENGINEERS 7940 SILVERTON AVENUE STE 208 SAN DIEGO CALIFORNIA 92126 TEL (858) 586 7B55 FAX (858) 566-7645 SHEET NO 2 OF_ CALCULATED BY CHECKED BY SCALE DATE. DATE. 04, Uj ;( 4- A- >. "2. =• ,-Z '.. J 7-C, /*= / 3 /A/ o fv ' ^ )&* A - r? 71f vp 1 Feb 22 06 07:21p Mobaued Consulting Group 858 586 7845 p. 8 JOB. MCG MOBAYED CONSULTING GROUP CONSULTING STPUCTURAL ENGINEERS 734O SILVEFTTON AVENUE STE 200 SAN DIEGO, CALIFORNIA 92126 TEL (658)566-7655 FAX (B5B) 5G6-7045 SHEET NO .3 CALCULATED BY_ CHECKED BY SCALE P - (, i M 1 V Feb, 22 06 07:22p Mobayed Consulting Group 858 586 7845 p.J Mobayed Consulting Group Tide. Job* &^>&)\^3 7940 SUverton Avenue, Smte 208 °*9nr , Date' 12 ™PM- **• FEB °6 San Die3o.CA 92126 DCSC"ptf°n (T) 858-586-7855, (F) 8585-586-7845 Scope ESs^c61'2^'™"™3 Timber Beam & Joist Page 1 | Description QUALIGEN (N) MECHL EQUIPMENT Timber Member Information Calculations are designed to 1997 NOS and 1997 UBC Requirements ^ Timber Section Beam Width in Beam Depth in Le Unbraced Length ft Timber Grade Fb - Basic Allow psiFv - Basic Allow psi Elastic Modulus ksi Load Duration Factor Member Type Repetitive Status J-2 J-3 3-2x4 2-2x4 4 500 3 000 3 500 3 500 000 000 Douglas Fir- Larch Douglas Fir Larch 1.3000 8250 95 0 95 0 1,9000 1,6000 1 250 1 250 Sawn Sawn No No | Center Span Data fj Span ft Dead Load #ffi Live Load #/ft Dead Load #/ft Live Load ft/ft Start ft End ft Point #1 DL Ibs LL Ibs @X ft Point #2 DL Ibs LL Ibs @X ft Point #3 DL Ibs LL Ibs @X fl 8 00 8 00 13 00 26 00 2000 1300 40 00 20 00 4 000 4 000 124 00 26 DO 30300 10700 4 000 4 000 2000 5500 6500 4750 [Results Ratio = 06969 09043 J Mmax @ Center in-k @X= ft ft) Actual psi Fb Allowable psi fv Actual psi Fv Allowable psi 1561 857 4 00 4 00 16988 1,3989 2,437 5 1 546 9 Bending OK Bending OK 41 7 41 6 1188 1188Shear OK Shear OK Reactions jf @ Left End DL Ibs LL Ibs Max DL+LL Ibs ©Right End DL Ibs LL Ibs Max DL+LL Ibs Deflections Center DL Defl in UDefl Ratio Center LL Defl in L/Defl Ratio Center Total Defl in Location ft UDefl Ratio 18566 11700 27150 19350 45716 31050 17934 11700 19150 15350 370 B4 270 50 Ratio > 240 « Ratio > 240 ! bu -0181 -0168 531 0 572 6 -0 243 -0 276 394 6 347 5 4 424 -0 444 3 968 3 968 2264 2163 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 PROJECT NAME QUALIGAN DATE 12/19/2005 iPROJECT ADDRESS ; 2042 CORTE DEL NOGAL #13 CARLSBAD "PRINCIPAL DESIGNER - ENVELOPE i ICS PACIFIC BUILDERS IDOCUMENTATION AUTHOR ; TELEPHONE : (858) 578-7500 iTELEPHONE Building Peimit* Checked by/Date Enforcement Agency Use IGENERAL INFORMATION iDATE OF PLANS i JBUILDING CONDITIONED FLOOR AREA 12/1 8/2006 1 1,752SqFt CLIMATE ZONE 7 ;BUILDINGTYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION _J NEW CONSTRUCTION """] ADDITION Hj ALTERATION | | EXISTING + ADDITION [STATEMENT OF COMPLIANCE jThis Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations This certificate applies only to a Building using the performance compliance approach ^The documentation preparer hereby certifies that the documentation is accurate and complete DOCUMENTATION AUTHOR IJTCNAfURE \ ~~ DATE " ICS PACIFIC BUILDERS iThe Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is f^ consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this ipermit application The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, Wough 118, and 140,142,143 or 149 of Title 24, Part 6 LTG MECH_ 1 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation, and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect 2 I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537 2 or 6737 3 to sign this document as the person responsible for its preparation, and that I am a licensed contractor performing this work i I I I I I ; — ' • — • L-- | ; 3 I affirm that I am eligible under Division 3 of the Business0and Professions Code to sign this document1 ' because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737 1 (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual ) [ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms j ENV-1 PRINCIPAL ENVELOPE DESIGNER - NAME i ICS PACIFIC BUILDERS SIGNATURE LIC NO IDATE [LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms LTG-1 PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC NO DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures PRINCIPAL MECHANICAL DESIGNER - NAME i ICS PACIFIC BUILDERS Required Forms JMECH-1, MECH-2, MECH-3 !LIC NO Run Initiation Time 12/19/05 18 06 34 Run Code 1135044394 EnergyPro 4 0 by EnergySoft User Number 2984 Job Number Page 2 of 19 £t\_"^^--, oCi ^>^ 7*> -, -iu> H(/» < 1 ^ ^ p jy^ ^ 0c~ OR^r ,j cr d ^ oO *— (— O Tl O > o: m rn D m! 3 £'••v> O \ 8 S5 % fcJ ^t< ^ l>si ?1* tt V,\<5 2jm»'"m \ CD 1) IS^BS ^8 • o o 30 o|psg|!SSiiiiiS2 I- n T I" ft I35^3j»o'