HomeMy WebLinkAbout2042 CORTE DEL NOGAL; C; CB993822; Permit06/16/2000
City of Carlsbad
Commercial/Industrial Permit Permit No CB993822
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
2042 CORTE DEL NOGAL CBAD St C
Tl Sub Type INDUST
2130610500 Lot# 0
$100,00000
SPEC SUITES
Construction Type
Reference #
Applicant
COPPER ROBERTS
STE C203
1010 UNIVERSITY AVE
SAN DIEGO CA 92103
619297-1011
Status ISSUED
NEW Applied 10/18/1999
Entered By MDP
Plan Approved 01/17/2000
Issued 01/17/2000
Inspect Area DM
Owner
QUINCE ASSOCIATES LTD
C/O SPECTRUM PROPERTY MANAGEMENT
8799 BALBOA AVE #260
SAN DIEGO CA 92123
Total Fees $10,71059 Total Payments To Date $10,710 59 Balance Due $000
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$621 33 Meter Size
$0 00 Add'l Reel Water Con Fee
$403 86 Meter Fee
$0 00 SDCWA Fee
$000 CFD Payoff Fee
$21 00 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 LFMZ Transportation Fee
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$000 MECHANICAL TOTAL
Master Drainage Fee
$0 00 Sewer Fee
$0 00 Redev Parking Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
. $000
$000
$1,94688
$1,797 12
$1,04000
$000
$000
$000
$000
$4,880 40
$000
$1071059
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr, Carlsbad CA 92009
(760)438-1161
FOR OFFICE USE ONLY
PLAN CHECK NO l\ "
EST VAL KDO.OOO
Plan Ck Deposit
Validated By
Date
Business Name (at this address)
Description of
2 CONTACT PERSON (if different/from Applicant)
Agent%r Contractor D Owner .JgAgent for Owner\0\0
Name
5 JXibNTRACTOR^CQMPA^iYNAME
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its
issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
er 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged
lion Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollarsj$500l)
City State/Zip
City Business License #
me
State License # ^7 ^ (fis'£> ^ooficw Pvfe<rh
ner Name
Address
License Class
Telephone it
011*ll00
Designer Name Address City State/Zip Telephone
State License #
6 ""WORKERS'COMPENSATION ^n ...-:— *"" ^ " ; _,.;= ij^- sjj, ••••- ; •*"•- ™:::"--
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
0 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance
of the^work for which this permit is issued
J^l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is
issued My worker s cornpensajion insurance carrier and policy number are
Insurance Company ($A Fy^lAACL { fa A#7>1 /iFift Policy No N'4'O^'l™ \ Co S\ Expiration Date_
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR 6jil4 HUNDRED DOLLARS [$100] OR LESS)
|~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING/ Fflilurejo-secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand *jHars"T§10Q QOOk in Addition tf the cost of compensation damages as provided for in Section 3706 of the Labor code i interest and attorney s fees
SIGNATURE / IMj$s |/UV~Y^-^Z>V--^n DATE ^' '" *~
T"!' OWNER .BUH.DER DECLARATION "' ~~~' f' 7j? J^"" " """ -;P~" ":-
1 hereby affirm that I am exempt from the Contractor s License Law for the following reason
l~l I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is
sold within one year of completion the owner builder will have the burden of proving that he did nol build or improve for the purpose of sale)
r~l I as owner of the property am exclusively contracting with licensed^etJntractors to construct the project (Sec 7044 Business and Professions Code The
Contractor s License Law does not apply to an owner of property^wno builds or improves thereon and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
l~l I am exempt under Section Businsss^and Professions Code for this reason
1 I personally plan to provide the major lahor'and materials for construction of the proposed property improvement l~| YES l~lNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the^following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to providejKTftions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone
number / contracjprs license number) _^
5 I wilLprovide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of wq
PROPERTY OWNER SIGNATURE DATE
COMPLETE,THIS SECTION I'FbR NON RESIDENTIAL BUILDING PERMITS ONLY • : f J
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? fj YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' O YES O NO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? O YES l~l NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8 JCONSTRUCTION LENDING AGENCY "" ' - [•- :.:^'" ^T : -gSp- ,:± t '"
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER S NAME _ LENDER S ADDRESS
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time a(ter th^jj«J{fjs ccrnime^cpd for a per||bd of 1 SO^daysJSeCljpn 106 4 4 Uniform Building Code)
APPLICANT S SIGNATURE
i commaBced for a perpd of 180 daysJSeCljp
DATE IP I It
WHITE File YELLOW Applicant PINK Finance
Inspection List
Permit* CB993822 Type Tl
Date Inspection Item
2/24/2000 84
2/23/2000 84
2/22/2000 14
2/22/2000 34
2/9/2000 17
2/8/2000 17
2/4/2000 14
2/2/2000 14
1/31/2000 14
1/31/2000 29
1/31/2000 39
1/19/2000 21
Rough Combo
Rough Combo
Frame/Steel/Bolting/Weldm
Rough Electric
Interior Lath/Drywall
Interior Lath/Drywall
Frame/Steel/Bolting/Weldm
Frame/Steel/Boltmg/Weldin
Frame/Steel/Bolting/Weldm
Final Plumbing
Final Electrical
Underground/Under Floor
INDUST
Inspector Act
DM
DM
DM
DM
DM
DM
DM
DM
DM
DM
DM
DM
AP
NR
NR
NR
AP
CA
AP
NR
CO
NR
NR
AP
SPEC SUITES
Comments
NO ONE AT SITE DOOR LOCKED
BY JOE
DRYWALL NAILING TO 9FT
Sunday July 16 2000 Page 1 of 1
City of Carlsbad Bldg Inspection Request
For 2/23/2000
Permit# CB993822
Title SPEC SUITES
Description
Inspector Assignment DM
Sub Type INDUST
2042 CORTE DEL NOGAL
C Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks PAGER 293-9900 CEILING INSP
Phone 7607546700
Inspector
Total Time
CD Description
14 Frame/Steel/Boltmg/Weldmg
24 Rough/Topout
34 Rough Electric
44 Rough/Ducts/Dampers
Requested By JOE JEFFERIES
Entered By CHRISTINE
Comments
#4-Aar\e
Associated PCRs
Date
2/9/2000
2/8/2000
2/4/2000
2/2/2000
1/31/2000
1/31/2000
1/31/2000
1/19/2000
Inspection Historv
Description
17 Interior Lath/Drywall
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
14 Frame/Steel/Bolting/Welding
14 Frame/Steel/Boltmg/Weldmg
29 Final Plumbing
39 Final Electrical
21 Underground/Under Floor
Act
AP
CA
AP
NR
CO
NR
NR
AP
Insp
DM
DM
DM
DM
DM
DM
DM
DM
Comments
BY JOE
DRYWALL NAILING TO 9FT
City of Carlsbad Bldg Inspection Request
For 2/22/2000
Permit* CB993822
Title SPEC SUITES
Description
Inspector Assignment DM
2042 CORTE DEL NOGAL
C Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks
Total Time
Sub Type INDUST
CD Description Act
14 Frame/Steel/Boltmg/Weldmg
34 Rough Electric
Phone 7607546700
Inspector
Requested By JOE
Entered By CHRISTINE
Comments
Associated PCRs
Date
2/9/2000
2/8/2000
2/4/2000
2/2/2000
1/31/2000
1/31/2000
1/31/2000
1/19/2000
Inspection History
Description
17 Interior Lath/Drywall
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
14 Frame/Steel/Bolting/Welding
14 Frame/Steel/Bolting/Welding
29 Final Plumbing
39 Final Electrical
21 Underground/Under Floor
Act
AP
CA
AP
NR
CO
NR
NR
AP
Insp
DM
DM
DM
DM
DM
DM
DM
DM
Comments
BY JOE
DRYWALL NAILING TO 9FT
City of Carlsbad Bldg Inspection Request
For 2/9/2000
Permits CB993822 Inspector Assignment DM
Title SPEC SUITES
Description
Type Tl Sub Type INDUST
Phone 7607546700
Job Address 2042 CORTE DEL NOGAL
Suite C Lot 0
Location Inspector
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks
Total Time Requested By JOE
Entered By ROBIN
CD Description Act Comments
17 Interior Lath/Drywall "A*
Associated PCRs
Inspection History
Date Description Act Insp Comments
2/4/2000 14Frame/Steel/Bolting/Welding AP DM DRYWALL NAILING TO 9FT
2/2/2000 14 Frame/Steel/Bolting/Welding NR DM
1/31/2000 14Frame/Steel/Bolting/Welding CO DM
1/31/2000 29 Final Plumbing NR DM
1/31/2000 39 Final Electrical NR DM
1/19/2000 21 Underground/Under Floor AP DM
City of Carlsbad Bldg Inspection Request
For 2/8/2000
Permit# CB993822 Inspector Assignment DM
Title SPEC SUITES
Description
Type Tl Sub Type INDUST
Phone 7607546700
Job Address 2042 CORTE DEL NOGAL
Suite C Lot 0
Location Inspector
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks 293-9900
Total Time Requested By JOE
Entered By ROBIN
CD Description Act Comments
17 Interior Lath/Drywall L.-/T 9&\ - \6^-
Associated PCRs
Inspection History
Date Description Act Insp Comments
2/4/2000 14 Frame/Steel/Boltmg/Weldmg AP DM DRYWALL NAILING TO 9FT
2/2/2000 UFrame/Steel/Bolting/Weldmg NR DM
1/31/2000 14Frame/Steel/Bolting/Weldmg CO DM
1/31/2000 29 Final Plumbing NR DM
1/31/2000 39 Final Electrical NR DM
1/19/2000 21 Underground/Under Floor AP DM
City of Carlsbad Bldg Inspection Request
For 2/4/2000
Permit# CB993822 Inspector Assignment DM
Title SPEC SUITES
Description
Type Tl Sub Type INDUST
Phone 7607546700
Job Address 2042 CORTE DEL NOGAL
Suite C Lot 0
Location Inspector
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks WALL FRM/293-9900
Total Time Requested By JOE
Entered By ROBIN
CD Description Act Comments
14 Frame/Steel/Boltmg/Weldmg /TT
Associated PCRs
Inspection History
Date Description Act Insp Comments
2/2/2000 HFrame/Steel/Bolting/Weldmg NR DM
1/31/2000 14Frame/Steel/Bolting/Weldmg CO DM
1/31/2000 29 Final Plumbing NR DM
1/31/2000 39 Final Electrical NR DM
1/19/2000 21 Underground/Under Floor AP DM
i-DS-OO O2 :r Rober"t,& Ben net. t GJL9 £97 3 fell'2 P
Ui
'wofm,nftan
./
/
./-.
18.
;:• ^;.--, .. ^, ? .. r io O £ "53s> co a D er fVobe r t s Benn^1
*
f- O
tfl'HOVVO bYJffi
J AJEUjflBIKS-4 S- '/• 'tjnt
,f-«. ^^T^O''" ...- -.iffi ftcts^i "f «M4S •». i!? S:V,H!,"^ suS***1***;*** Wi'«iii«!Kifcfflv«ifc«»|K ^» ^bi.',u:^~ ^T ^ „,;-,„.:: =.*#, fiU/ra- ^a!^fi«) fa ^j",«L' X e;J&At" ®A iv«ta sPytSl &2 *^<S£*^; E,««eft s,*f.^ ^ Mj-Jf'^0 J'^>twiAJf^-Sfr-"* s '" ^ ^IWSP«*«&<a«*P*»M!g«ifttfl^i
^iQ&S^tfis'
1 "1*446 "
Pff flWj'BS* - m • • • - a- i *-t w -- ^.- - - r -— -a - U--.--..o>rS9 *iff*7B*• ^f'fe^r^I-f' "s^;- i^s H^v-t',*-,^ f'" o^ ^vtrfT^
4i' r; i0.i>' on
City of Carlsbad Bldg Inspection Request
For 2/2/2000
Permit# CB993822
Title SPEC SUITES
Description
Inspector Assignment DM
2042 CORTE DEL NOGAL
C Lot 0
Type Tl Sub Type INDUST
Job Address
Suite
Location
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks PGR 293-9900
Phone 7607546700
Inspector
Total Time Requested By JOE
Entered By ROBIN
CD Description Act Comments
14 Frame/Steel/Boltmg/Weldmg
Associated PCRs
Inspection History
Date Description Act Insp Comments
1/31/2000 14 Frame/Steel/Boltmg/Weldmg CO DM
1/31/2000 29 Final Plumbing NR DM
1/31/2000 39 Final Electrical NR DM
1/19/2000 21 Underground/Under Floor AP DM
City of Carlsbad Bldg Inspection Request
For 1/31/2000
Permit# CB993822
Title SPEC SUITES
Description
Inspector Assignment DM
2042 CORTE DEL NOGAL
C Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks PAGER 760/293-9900
Sub Type INDUST
Total Time
CD Description
Phone 7607546700
Inspector
Act Comments
14 Frame/Steel/Boltmg/Weldmg ^-^j / ./I
29 Final Plumbing
39 Final Electrical
Requested By JOE
Entered By ROBIN
Associated PCRs
Inspection History
Date Description Act Insp Comments
1/19/2000 21 Underground/Under Floor AP DM
City of Carlsbad Bldg Inspection Request
For 1/19/2000
Permit# CB993822
Title SPEC SUITES
Description
Inspector Assignment
2042 CORTE DEL NOGAL
C Lot 0
Type Tl Sub Type INDUST
Job Address
Suite
Location
APPLICANT COPPER ROBERTS
Owner QUINCE ASSOCIATES LTD
Remarks
Phone 7607546700
Inspector
Total Time
CD Description Act Comments
AP21 Underground/Under Floor
Requested By JOE
Entered By CHRISTINE
Associated PCRs
Inspection History
Date Description Act Insp Comments
EsGil Corporation
In Partners/lip Witfi. government for
DATE 11/2/99 a ^APPLICANT
JURIS
JURISDICTION Carlsbad
a FILE
PLAN CHECK NO 99-3822 SET I
PROJECT ADDRESS 2042 Corte del Nogal Ste. C
PROJECT NAME Speculative Suite Tenant Improvement
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Cooper Roberts Bennett
1010 University Ave Ste C203 San Diego, Ca 92103
Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has
been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Mike Puckett Enclosures
Esgil Corporation
D GA D MB D EJ D PC 10/21/99 trnsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576
Carlsbad 99-3822
11/2/99
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 99-3822
OCCUPANCY B/S1
TYPE OF CONSTRUCTION VN
ALLOWABLE FLOOR AREA
SPRINKLERS'? Yes
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 10/18/99
DATE INITIAL PLAN REVIEW
COMPLETED 11/2/99
JURISDICTION Carlsbad
USE Office/Warehouse
ACTUAL AREA 6,885sfTI
STORIES
HEIGHT
OCCUPANT LOAD 68 TI
DATE PLANS RECEIVED BY
ESGIL CORPORATION 10/21/99
PLAN REVIEWER Mike Puckett
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i e . plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
/ \
Carlsbad 99-3822
11/2/99
1 Please make all corrections on the original tracings, as requested in the correction list
Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be submitted
in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760)
438-1161 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver
all remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
2 Please show the occupant load for the proposed tenant improvement on the plans
3 Please show on the site plan the complying disabled accessible path of travel from
the disabled accessible parking spaces to the tenant space entrance
4 Please dimension the length of the room 100 on the plans
5 Please show the use of the room that will have the door removed as per item #8 on
sheet TI-3
6 Please show the inscribed 60" maneuvering circle in the restrooms on the floor plan
for the restrooms dimensioned on the plans Show that the doors cannot encroach
more than 12" into the required circle Note, the detail on sheet Tl -7 shows all this,
however, the restroom shown in the detail has no dimensions
7 Show on the plans ventilation requirements of UBC Section 1202 2 1 for t he tenant
space If no HVAC is provided, other means of ventilation must be provided Show
the location of the ventilating fans on the plans, the cfm of the units installed and
provide the calculations to show compliance with the above UBC Section If the
HVAC will be added to provide the required ventilation, then provide the required
energy calculations for Envelope, Mechanical and Electrical and imprint the ENV-1,
MECH-1 and LTG-1 forms on the plans
8 Please show an exit light at the opening between the tenant spaces
9 Please revise the general notes on sheet E-2 as per the City of Carlsbad and note
that "No AC cable or Romex wiring methods are allowed"
Carlsbad 99-3822
11/2/99
10 Per the City of Carlsbad request, please note the following on the plans
a) Roof mounted equipment must be screened and roof penetrations should
be minimized (City Policy 80-6)
b) No wiring is permitted on the roof of a building and wiring on the exterior of
a building requires approval by the Building Official (City Policy)
c) All roof-mounted equipment shall be concealed from view Provide
structural detailing for the screening
11 Please attach the accompanying City of Carlsbad Roof Mounted Equipment policy to
the plans
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i e , plan sheet, note or detail number, calculation page,
etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly describe
them and where they are located in the plans
Have changes been made to the plans not resulting from this correction list? Please
indicate
Yes G No Q
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468,
to perform the plan review for your project If you have any questions regarding
these plan review items, please contact Mike Puckett at Esgil Corporation Thank
you
CITY OF CARLSBAD
POLICIES AND PROCEDURE
NUMBER 80-6 SUBJECT ROOF MOUNTED EQUIPMENT
EFFECTIVE 5/1/92 SECTION BUILDING DEPARTMENT
SUPERSEDES^80-6(9/10/80)
80-6(5/01/81}
PURPOSE
INTENT
PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND
PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS
A Maintain roof integrity
B Prevent hazardous condition to firemen who must fight fire on the roof
C Provide an installation that is aesthetically sensitive to the building and the
adjoining properties
POLICY 1 All equipment shall be concealed from view and the design* shall meet the
approval of the Planning Department
2 All equipment shall be specifically designed and approved for exterior use and
shall be approved by the City of Carlsbad Building Department
3 All roof mounted equipment shall be on a platform which shall be an integral
part of the roof-flashed and waterproofed When a screen is approved, it shall
have as few roof connections as possible and be structurally adequate
4 All electrical, plumbing, mechanical duct work and related piping shall be inside
the building and not on the roof All connections related to equipment shall be
made in the same roof opening on the platform or have the prior approval from
the building official
5 Sewer vents shall be brought to one mam vent below the roof and have one
penetration where restrooms or other plumbing fixtures are back to back or in
the general proximity
Air exhaust fans and other equipment shall be within the building and use the
same roof opening where restrooms and other equipment are back to back or in
general proximity
6 Existing buildings and equipment, remodel or replacement, shall meet the above
regulations or shall have the prior approval from the building official
7 Where new equipment is installed, unused or abandoned equipment, including
all roof mounted piping, electrical, mechanical, duct, and other related
appurtenances shall be removed from roof and unused openings properly sealed
to maintain roof integrity
*The architect should, through design, conceal the heatmg/AC unit and other equipment whether
they are on the roof or elsewhere
jated By Approved B
Carlsbad 99-3822
11/2/99
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Mike Puckett
PLAN CHECK NO 99-3822
DATE 11/2/99
BUILDING ADDRESS 2042 Corte del Nogal Ste C
BUILDING OCCUPANCY B/S1 TYPE OF CONSTRUCTION VN
BUILDING PORTION
Tenant Improvement
Air Conditioning
Fire Sprinklers
TOTAL VALUE
BUILDING AREA
(ft2)
6,885
VALUATION
MULTIPLIER
City Value
VALUE
($)
100,00000
100,00000
n 1994 UBC Building Permit Fee H Bldg Permit Fee by ordinance $62108
D 1994 UBC Plan Check Fee O Plan Check Fee by ordinance $ 403 70
Type of Review [~l Complete Review Q Structural Only Q Hourly
Q] Repetitive Fee Applicable Q Other
Esgil Plan Review Fee $ 322 96
Comments
Sheet 1 of 1
macvalue doc 5196
City of Carlsbad
Engineering Department
DATE
BUILDING ADDRESS _
PROJECT DESCRIPTION
ASSESSOR'S PARCEL NUMBER
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO CB
£
-OS
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans
information and/or specifications provided in your
submittal therefore any changes to these items after
this date including field modifications must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached as failure to comply
with instructions in this report can result in
suspension of permit to build
LA Right-of-Way permit is required prior to
construction of the following improvements
EST VALUE
DENIAL
Please seeVthg, attached report of deficiencies
marked witJ>BTivlake necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
Date
Date
//*/*
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT
Date
Dedication Application
-J Dedication Checklist
—1 Improvement Application
Li Improvement Checklist
_i Future Improvement Agreement
r. Grading Permit Application
•...I Grading Submittal Checklist
_, Right-of-Way Permit Application
H Right-of-Way Permit Submittal Checklist
and Information Sheet
ENGINEERING DEPT CONTACT PERSON
Name JOANNE JUCHNIEWICZ
City of Carlsbad
Address 2075 Las Palmas Dr Carlsbad CA 92009
Phone (619)438-1161 ext 4510
CFD INFORMATION
Parcel Map No
Lots
Recordation
Carlsbad Tract
• 1 Sewer Fee Information Sheet A-4
CA 92OO9-^576 • (760) 438-1161 • FAX (76O)
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
A North Arrow
B Existing & Proposed Structures
C Existing Street Improvements
2 Show on site plan
B
D Property Lines
E Easements
F Right-of-Way Width & Adjacent Streets
G Driveway widths
Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
Existing & Proposed Slopes and Topography
3 Include on title sheet
Site address
Assessor's Parcel Number
Legal Description
commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc ) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
Q 4a Project does not comply with the following Engineering Conditions of approval for
Project No
4b All conditions are in compliance Date
H \WORD\DOCS\CHKLSTiBuildmg Plancheck Cklst BP0001 form JJ doc Rev 12/26/96
oND/
BUILDING PLANCHECK CHECKLIST
DEDICATION REQUIREMENTS
5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
dram or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ , pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 1/2" x 11" plat map
and submit with a title report All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist for the dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
IMPROVEMENT REQUIREMENTS
Q Q 6a All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ , pursuant to Carlsbad Municipal Code
Section 1840040
Public improvements required as follows
Attached please find an application form and submittal checklist for the public
improvement requirements A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process The completed application form and the requirements on the
checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by Date
6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $ so
we may prepare the necessary Future Improvement Agreement This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit
Future public improvements required as follows
H \WORD\DOCS'CHKLST\Buil(Jing Plancheck Cklst BP0001 Farm JJ doc
BUILDING PLANCHECK CHECKLIST
I st/ ond/ ord/
Q Q Q 6c Enclosed please find your Future Improvement Agreement Please return
agreement signed and notarized to the Engineering Department
Future Improvement Agreement completed by
Date
Q Q Q 6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11 06 030 of the Municipal Code
Q Q Q 7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities (cut, fill import, export)
Q Q rj 7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
Grading Inspector sign off by Date
Q Q 7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required )
Q Q 7d No Grading Permit required
Q Q 7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
Q Q 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tiemg
into public storm dram, sewer and water utilities
Right-of-Way permit required for
BUILDING PLANCHECK CHECKLIST
H \WORD\DOCS\CHKLST\Building Plancheck Cklst BP0001 Form JJ doc A Rev 12/28/96
HSt
Q
pnd-/
Q Q A SEWER PERMIT is required concurrent with the building permit issuance
fee is noted in the fees section on the following page
The
10 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 153, for
assistance
Industrial Waste permit accepted by
Date
11 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
Required fees are attached
No fees required
13 Additional Comments
H \WOROVDOCS\CHKLS'P.BuMina Planctiecu Cklst BPOOm Form JJ doc
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
a .Estimate based on unconfirmed information from applicant
&T Calculation based on building plancheck plan submittal.
Address /&)/,feD U ClBldg. Permit No.
Prepared by: ,~VS
EDU CALCULATIONS:
Types of Use:
Types of Use:
APT CALCULATIONS:
(j-Gi- U*-o-fe-'
Types ofUse:
Types of Use:
Date. //3 /C& Checked by:L i
List types and square footages for all uses.
" ^ Sq. Ft /Units:
Sq Ft/Units-
List types and square footages for all uses.
**^ Sq. Ft./Units:
Sq. Ft /Units:
Date-
EDU's
EDU's
ADT's-
ADT's-
3.H5
M
FEES REQUIRED:
WITHIN CFD: DYES (no bridge & thoroughfare fee m District t\. reduced Traffic Impact Fee)
H PARK-IN-UEU FEE PARK AREA & #.
FEE/UNIT.X NO UNITS.
2 TRAFFIC IMPACT FEE
ADT's/UNITS.X FEE/ADT-
ZONE TRANSPORTATION AOT'S /O/ X $70
BRIDGE AND THOROUGHFARE FEE IDIST #1 DIST. #2 DIST. #3
ADT's/UNITS:X FEE/ADT.
FACILITIES MANAGEMENT FEE
UNIT/SQ.FT :
5 SEWER FEE
PERMIT No
EDU's. d-H
ZONE
X FEE/SO FT /UNIT
BENEFIT AREA.
EDU's cP L/5
6 SEWER LATERAL ($2,500)
"7 DRAINAGE FEES PLDA_
ACRES
X FEE/EDU
DRAINAGE BASIN
X FEE/EDU
_ HIGH /LOW
X FEE/AC
TOTAL OF ABOVE FEES* $
*NOTE. This calculation sheet is NJDT a complete list of aB fees which may be due
Dedications and Improvements may also be required with Building Permits
3-83
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
o d
o
o Plan Check No CB
Planner yau I
APN '213-
Address Bus
Phone (619) 438-1161, extension
Ic
Type of Project & Use _
Zoning PH General Plan Pi
Net Project Density
Facilities Management Zone
DU/AC
CFD Im/niit) #_
Circle One
.Date of participation Remaining net dev acres
5creE
15<u.c(J
(For non-residential development Type of land used created by
this permit )
Legend Item Complete
I I |~| Environmental Review Required
DATE OF COMPLETION
YES
Item Incomplete - Needs your action
NO TYPE
Compliance with conditions of approval7 If not, state conditions which require action
Conditions of Approval
[_J Discretionary Action Required
APPROVAL/RESO NO
PROJECT NO
YES NO \ TYPE
DATE
OTHER RELATED CASES
Compliance with conditions or approval7 If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone7 YES
CA Coastal Commission Authority7 YES NO
If California Coastal Commission Authority Contact them at - 3111 Camino Del Rio North, Suite
200 San Diego CA 92108-1725 (619)521-8036
Determine status (Coastal Permit Required or Exempt)
Coastal Permit Determination Form already completed7 YES NO
If NO complete Coastal Permit Determination Form now
Coastal Permit Determination Log #
Follow-Up Actions
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans)
2) Complete Coastal Permit Determination Log as needed
Inclusionary Housing Fee required YES NO
(Effective date of Inclusionary Housing Ordinance - May 21 1993 )
Data Entry Completed? YES NO
(A/P/Ds Activity Maintenance enter CB# toolbar Screens Housing Fees Construct Housing Y/N Enter Fee UPDATE1)
Site Plan
| | | | 1 Provide a fully dimensional site plan drawn to scale Show North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines
[ j | | 2 Provide legal description of property and assessor's parcel number
Zoning
| | O 1 Setbacks
Front
Interior Side
Street Side
Rear
2 Accessory structure
Front
Interior Side
Street Side
Rear
Structure separation
3 Lot Coverage
Required
Required
Required
Required
setbacks
Required
Required
Required
Required
Required
Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
D 4 Height Required
5 Parking Spaces Required
Guest Spaces Required
Additional Comments
Shown _
Shown
Shown
DK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE \
PARKING REQUIRED PARKING PROVIDED
OFFICE 18,373 S F @ 4/1000 = 74
MANUFAC 22 937 S F @ 3/1000 = 69
WAREHOUSE 21.250SF 01/1000 = 22
TOTAL 165
REGULAR
COMPACT
HC
148
37
8
TOTAL 193
EsGil Corporation
In Tartnership with government for
DATE 12/21/99 CLABEUQANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 99-3822 SET II
PROJECT ADDRESS 2402 Corte del Nogal Ste C
PROJECT NAME Speculative Suite Tenant Improvement
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified in Remarks below are resolved and checked by building
department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
(i A*REMARKS Please make the notes as in red on sheets/T-T and E1 of the Owner Set II
plans to the City held Set II plans The applicant wilLefarry one perforated Owner Set II
plan to the City of Carlsbad Building Department, tdday She was advised that a permit
may or may not be issued at the time of delivery/
By Mike Puckett Enclosures
Esgil Corporation
D GA n MB D EJ D PC log trnsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576
Carlsbad Fire Department 990401
2560 Orion Way
Carlsbad CA 92008
Plan Review Requirements Category
Date of Report 01/11/2000
Fire Prevention
(760)931-2176
Building Plan
Reviewed by
Name
Address
COOPER ROBERTS & CO
1010 UNIVERSITY AV C203
City, State SAN DIEGO CA 921 os
Plan Checker
Job Name Spec Suite
Job # 990401
Job Address 2042 Corte Del Nogal
Bldg # CB993822
Ste or Bldg No
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st 2nd 3rd
990401 FDFile#
Other Agency ID
Carlsbad Fire Department 990401
2560 Orion Way
Carlsbad, CA 92008
Plan Review Requirements Category
Date of Report 11/12/1999
Fire Prevention
(760)931-2121
Building Plan
Reviewed by
Name
Address
COOPER ROBERTS & CO
1010 UNIVERSITY AV C203
City, State SAN DIEGO CA 92103
Plan Checker
Job Name Spec Suite
job # 990401
Job Address 2042 Corte Del Nogal
Bldg # CB993822
Ste or Bldg No C
D Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in ,
suspension of permit to construct or install improvements
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FDJob#
1st 2nd 3rd
990401 FDFiletf
Other Agency ID
Requirements Category Building Plan
Requirement Pending 0514 Provide Technical Report
To determine the acceptability of technologies, processes products facilities, materials and uses
attending the design, operation or use of a building or premises subject to the inspection of the
department, the Chief is authorized to require the owner or the person in possession or control of the
building or premises to provide, without charge to the jurisdiction, a technical opinion and report The
opinion and report shall be prepared by a qualified engineer specialist, laboratory or fire-safety
specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety
properties of the design, operation or use of the building or premises and the facilities and
appurtances situated thereon, to recommend necessary changes
Pagel 11/12/99
TrtH-10-00 MOM 05 42 PM JJ C O H S T R U C T I OH '" 0 * I NG 619 754 1206 P 04
S.'c'e cf Co.ifo'niO
CONTRACTORS STATE ifCENSE BOARD
ACTIVE LICENSE
tdiir CORP
.. BREEZE CONSTB2&TION DBA JJ
CONSTRUCTION
ll /30/20 00
JHN-IW-QM MUM ws 40 PM TT CONSTRUCTION >.0*iNG e. i 9 754 1206 F O.I
JJ CONSTRUCTION
License No 356305
2741 Vista Way, Ste 201
Oceanside, CA 92054
Telephone (760) 754-6700 Fax (760) 754-6702
January 10,2000
RE Tenant Improvement Project
2042 Corte Del Nogal
Carlsbad, CA 92008
To Whom it May Concern.
This letter will serve as authorization for Cooper, Robeits. Bennett to pull permit on behalf of
JJ Constiuction, the General Contiactoi on the project refeienced above
ffrey
JJ CONSTRUCTION
C \CiNRI.PROr.CORTEDEL-.PERMIT ATM
MUM 05 41 PM J..T COH
ACORD, CERTIFICATE OF LIABILITY INSURANCEjjgjfo ™v"^_
FHOC-JCER
Watendge Insurance Services
10525 Vista Sorrento Pkwy #300
San Dieg-o CA 92121
Beth Billstein
=--'.. N= 858-452-2200 FIX NO 858-452-6004
J J Construction
Seabreeze Construction D3A
2741 Vista Way #201
Oceanside CA 92054
THIS CERTiFICATE 'S ISSUED AS A MATTER OF INFORMATION
ON'LY AND CONFERS NO RIGHTS UPON TH= CERT FiCATE
HOLDER THIS CERTiFICATE DOES NOT AMEND EXTEND OR
ALTER THE COVERAGE AFFORDED BY THE POLiCiGS BELOW
COMPANIES AFFORDING COVERAGE
COMPANY
A California Indemnity Ins Co
COMPANY
I B
' COMPANYi c
i COMPANY
D
COVERAGES
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE JSTED BELOW HAVE SEEM ISSUED TO THE INSURED NAMED ABOVE FOR THE POL'CV PERIOD
INDICATED NOTWITHSTANDING ANY REQUIREMENT TERM Or? CONDITION OF ANY CONTRACT OR OTHER DOCUMENT V\TH RESPECT ~O WHICH THIS
CERTIFICATE VAV BE ISSUED OR MAY PERTAiN THE INSURANCE AFFORDED BY THE POLiClES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS
EXCLUSIONS AND CONDIT ONS OF SUCH POLICIES LlMI'S SHOWN MAV HAVE BEEN REDUCED BY PA^D CLAIMS
i
,-Lp i TYPE DP IN SURA*;
i GE -ERA1. '.lABILIT'
CC-'-WERCIA. GENERA
! \ | C.AiMSMACE
OWNER S1CON7RAC'
I I
?E POLICY NUMBSR
/
LLiASILCY
J OCCUR
"OR S PROT
; 1 '
ALTOMCB!i.E LIABILITY
ANY AUTO
| A.1.. CVVNEC A'JTOS
J SCHEDULED AUTOS
^ | HIRED AIJTOS
NON OWNED A.'JTCS
! i
GARASEUABXT'
j ANV AU'O
j
POLICY EFFECTIVE PC-.'CY EXPIRATION
DATE (MMJOOfTf) DATE (MM/DO/YY; - Y s
I GENERAL AGGREGATE
I PRODUCTS COMf/0? AGO
PERSONA. & A.DV INJURY
j EACH OCCURRENCE
j F iftE DAMAGE (Any ore I.,-.)
j MED EXP !Ar.y one pe.-sor.)
CCMBINEC SINGLE LIMiT
i BODILY INJURY(3er person;
BODILY INJURY(Per »:::cer.\
PROPERTY DAMAGE
i ALTC ONLY EA ACCiOENT
| OTHER THAN AUTO ON..Y
S
5
$
%
S
S
S
»
S
r, " "
'
EACH ACCIDENT [ $
' AGGREGATE ! $
; EXCESS L'ASILiTY
JMBRELLA FORM
r ; OTHER THAN UMBRELLA FORM
; WORKERS CCMPENSAT.ON ANC \
A . w|TPr?E°P&E«CJ-ve r~]llS'c'- N3059916A
OFFICERS ARE EXC1. i
OTHER
.'
EACH OCCvRRt'JCE
j AGGREGATE
I
X IWCS'A'U i :OT'..'TORY LIMITS i ER
' EL EACH ACCDENT
07/02/99 07/02/00 EL CISEASS POLICY LIMIT
EL DISEASE EA EMPLOYEE
S
$
s 1,000,000
s 1,000,000
s 1,000,000
:E5CP.IP"ICN OF OPEWIONS/LOCATIGNS-VEHICLES/SPECIA. ITEMS
aerftfuixa'-
CERT! = ;CATE HOLDER
ess
^^^^^^^^^^^^^
ACORD 25-8(1/95)
MWCONS3
•MM^r^M*
' *fc- ^^^^^ t^-
CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED PCJCIES bE CANCELLE
EXPIRATION BATE Tt-EREOF THE ISSUING COMPANY Wit;. ENOEA
3 0 * DAYS WRITTEN NOTICE TO T-E CERTIFICATE HOLDER NA
BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE SO OSLIOAT'C
OF ANY KIND UPON "THE COMPANY Ts AGENTS OR REFRESEN7A1
^
J BEFORE 'HE
/OR "O MA...
•iEOTOT-iSLEF'
N OR LIAS Li~i'
•"VES
AUTHORIZED REPRESENTAT;VE ,'} . _ } ,.
Beth Billstein ,^rV.iLV^ S \~^U<-£^''(£' <_,y'~(__,
ACORD CORPORATION1 19?c
Catlstfad Fire Department 990401
2560 Orion Way
Carlsbad CA 92008
Plan Review Requirements Category
Date of Report 11/12/1999
Fire Prevention
(760)931-2121
Building Plan
Reviewed by
Name
Address
COOPER ROBERTS & CO
1010 UNIVERSITY AV C203
City, State SAN DIEGO CA 92103
Plan Checker
Job Name Spec Suite
job # 990401
Job Address 2042 Corte Del Nogal
Bldg # CB993822
Ste or Bldg No C
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FDJob#
1st 2nd 3rd
990401 FDFile#
Other Agency ID
Reqfjiref.Tents Category Building Plan
Requirement Pending 0514 Provide Technical Report
To determine the acceptability of technologies processes products, facilities, materials and uses
attending the design, operation or use of a building or premises subject to the inspection of the
department, the Chief is authorized to require the owner or the person in possession or control of the
building or premises to provide, without charge to the jurisdiction, a technical opinion and report The
opinion and report shall be prepared by a qualified engineer specialist, laboratory or fire-safety
specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety
properties of the design, operation or use of the building or premises and the facilities and
appurtances situated thereon, to recommend necessary changes