HomeMy WebLinkAbout2045 CORTE DEL NOGAL; ; CB081877; Permit12-31-2008 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB081877 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2045 CORTE DEL NOGAL CBAD Tl Sub Type 2130610900 Lot# $45,450 00 Construction Type Reference # 996 SF CMU ENCLOSURE W/ROOF FOR MECHANICAL EQUIPMENT-NO TENNANT INDUST 0 5B Applicant MARK SWENSON STE 200 6125 CORNERSTONE CT 92121 858 866-0889 Status ISSUED Applied 10/02/2008 Entered By RMA Plan Approved 12/31/2008 Issued 12/31/2008 Inspect Area Plan Check* Owner TEYSSIER L&M FAMILY TRUST 10-14-92 C/0 ATOMIC INVESTMENTS 3200 B4-2 HIGHLAND AVE NATIONAL CITY CA 91950 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee Green Bldg Stands (SB1473) Fee $392 28 Meter Size $0 00 Add'l Reel Water Con Fee $254 98 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $954 PFF (3105540) $398 40 PFF (4305540) $000 License Tax (3104193) $132 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees 7? HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $249 60 $230 40 $000 $000 $000 $000 $244 60 $000 $000 79 $1,911 80 Total Fees $1,911 80 Total Payments To Date n.i $1,911 80 Balance Due PI A "MS, $000 IN STORAGE ATTACHED Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations or other exactions hereafter collectively referred to as lees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required 'nformation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to watei and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which von have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired City of Carlsbad 1635 Faraday Ave , Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www carlsbadca gov Building Permit Application JOB ADDRESS SUITE#/SPACE#/UNIT# CT/PROJECT*LOT*PHASE tf tt OF UNITS # BEDROOMS # BATHROOMS DESCRIPTION OF WORK Include Square Feet of Affected Area(s) Room tftf/ EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YES D #NO D AIR CONDITIONING YES D NO D FIRE SPRINKLERS YES D NO D CONTACT NAME (If Different Font Applicant)APPLICANT NAME ADDRESS ADDRESS CITY STATE ZIP ZIP PHONE FAX -ojy? EMAIL EMAIL PROPERTY OWN^R NAMEf /MONICA CONTRACTOR BUS NAME ADDRESS CITY 3d ZIP 1I1SV CITY STATE ZIP PHONE FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS CLASS CITY BUS LIC # [Sec. 70315 Business andlicensed oursuant to th Section 70315 by any less and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that lie is exempt therefrom, ind cite basis For the alleged exemption Any violation of1 any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}) S^S^S^S^^E^ Workers' Compensation Declaration / hereby affirm under penally ol perjury one of the following declarations L~J I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued G I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers' compensation insurance earner and policy number are Insurance Co ___ Policy No _ Expiration Date _ section need not be completed if the permit is for one hundred dollars ($100) or less Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&1 00,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees JS$ CONTRACTOR SIGNATURE DATE / hereby affirm that I am exempt from Contractor's License Law lor the following reason fS(j I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's bcense Law does not apply to an owner of property who builds or improves thereon, and who does such work himsell or through his own employees, provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O Yes D No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have_C2ntracted with the following person (firm) lo provide the proposed construction (include name address / phone / contractors' license number) 4 kjfan to providS portions oMne work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors license number) «I v ill prowis-soine ol the^voijj^it I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) /I I /1, Is the applicant or future building occupant required to submit a business plan^acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley Tanner Hazardous Substance Account Act9 D Yes Sfno Is the applicant or future building occupant required to obtain a permit Irom the air pollution control district or air quality management district7 CJ Yes 3-NiT Is the facility to be constructed within 1,000 feet of the outer boundary of a school site7 D Yes IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name ^ | 1 Lender's Address ill I certify that I have read the application and slate that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CfTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit B required for excavations over 5'0' deep and demolition or construction of structures over 3 stones m height EXPIRATION Every permit issued by the Building Official under the provisions of the Code shall expire by limitation and become null and void if the building or work authorized by such permit B not commenced within 1 80 days from the date of such permit or if the buJHlhg or work authorized by such perml B suspended or abandoned at any time after the work s commenced for a period of J80 days (Section 1 06 4 4 Uniform Building Code) ^APPLICANT'S SIGNATURE /^ Ij DATE UNSCHEDULED BUILDING INSPECTION DATE <//?/o4 INSPECTOR PERMIT # C6&0/877 PLAN CHECK # JOB ADDRESS -Zc*s<T /gacre fftt DESCRIPTION CODE DESCRIPTION ACT COMMENTS Inspection List Permit* CB081877 Date Inspection [tern 04/07/2009 89 Final Combo 03/04/200919 Final Structural Type Tl INDUST 03/04/2009 92 03/02/2009 19 03/02/2009 19 Compliance Investigation Final Structural Final Structural Inspector TP TP TP Act AP CO Rl Rl CO 996 SF CMU ENCLOSURE W/ROOF FOR MECHANICAL EQUIPMENT-NO TENN Comments BLDG ACCESSABLE PARKING & ROUTE TO BLDG ADA COMPLIANCE - LATE MORNING PM 12-1 Wednesday, April 08, 2009 Page 1 of 1 City of Carlsbad Bldg Inspection Request For 03/04/2009 Permit* CB081 877 Inspector Assignment TP Title 996 SF CMU ENCLOSURE W/ROOF Description FOR MECHANICAL EQUIPMENT-NO TENNANT Type Tl Sub Type INDUS! Phone 3109956176 Job Address 2045 CORTE DEL NOGAL Suite Lot 0 Location Inspector OWNER TEYSSIERL&M FAMILY TRUST 10-14-92 Owner TEYSSIER L&M FAMILY MARITAL TRUST 10-14-92 Remarks ADA COMPLIANCE - LATE MORNING Total Time _ Requested By CONTRACTOR Entered By CHRISTINE CD Description Act Comments 9? Compliance Investigation fa Comments/Notices/Holds Associated PCRs/CVs Original PC# CV030273 CLOSED H- CONSTRUCTION W/OUTPERMIT, CV080321 CLOSED Z- BUSINESS LICENSE DENIED, CV080374 OPEN II- ILLEGAL CONSTRUCTION, PCR03094 EXPIRED SEASII.VER REVELECSCII. PCR03100 EXPIRED SEASILVER-Dni-' SUBMIT-REV A. TANKS-SESMIC & CONNECTIONS Inspection History Date Description Act Insp Comments EsGil Corporation In (Partnership with government for (Buihfing Safety DATE 12/10/08 JURISDICTION Carlsbad PLAN CHECK NO 08-1877 SET II PROJECT ADDRESS 2045 Corte Del Nogal PROJECT NAME New Mechanical Equipment Room Q PLAN REVIEWER Q FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes [X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to X] Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Date contacted Mail Telephone (by ) Fax In Person REMARKS City staff to verify fi without automatic fire sprinklers By Chuck Mendenhall Esgil Corporation D GA D MB D EJ PC Telephone # Fax # approval of the mechanical equipment enclosure Enclosures 12/3/08 EsGil Corporation In (Partnership with government for (Buifcfing Safety DATE 10/13/08 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 08-1877 SET I PROJECT ADDRESS 2045 Corte Del Nogal PROJECT NAME New Mechanical Equipment Room The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Mark Swenson, Studio 'C' 6125 Cornerstone Ct, #200, San Diego, CA 92121 Esgil Corporation staff did not advise the applicant that the plan check has been completed X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mark Swenson Telephone # (858) 866-0889 Date contacted ,c('2/c$-(by ,-A-) Fax # (858)866-0868 Mail - Telephone Fax./ In Person REMARKS By Chuck Mendenhall Enclosures Esgil Corporationn GA n MB n EJ n PC 10/6/08 9320 Chesapeake Drive, Suite 208 ^ San Diego, California 92123 0 (858)560-1468 ^ Fa\ (858) 560-1576 Carlsbad 08-1877 10/13/08 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO 08-1877 OCCUPANCY Fl TYPE OF CONSTRUCTION III B JURISDICTION Carlsbad USE Machinery Room ACTUAL AREA 996 ALLOWABLE FLOOR AREA Unknown STORIES one SPRINKLERS'? No REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED 10/13/O8 HEIGHT 12'-6" approx per IBC OCCUPANT LOAD 5 DATE PLANS RECEIVED BY ESGIL CORPORATION 10/6/08 PLAN REVIEWER Chuck Mendenhall FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e , plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Carlsbad O8-1877 10/13/O8 Please make all corrections, as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 The occupancy classification listed on the cover sheet is 'U' occupancy The proposed is an equipment machinery room and must be classified as an F-1 occupancy per CBC 306 1 2 The cover sheet lists the building construction as type VB and not sprmklered Provide an area analysis of the existing building as type VB construction and no sprinklers to show the existing plus added area is allowed per CBC Table 503 3 Automatic sprinklers are required for buildings having an aggregate floor area of 5,000 sq ft or more Existing buildings in which the aggregate floor area is expanded and exceeds 5,000 square feet shall be provided with fire sprinklers City ordinance 4 What type of mechanical machinery will be installed within this machine room Will there be refrigeration equipment? Will there be boilers9 Note that boilers may not be located within a refrigeration (chiller) room 5 The machinery room for boilers and /or refrigeration equipment must be separated from the remainder of the building per Table 508 2 It appears that the existing tilt up concrete wall is sufficient However, openings for doors and or ducts passing through the wall must compOly with CBC Section 706 7 6 Provide a Building Code Data Legend on the Title Sheet Include the following code information for each building proposed ° Occupancy Classification(s) « Description of Use o Justification to exceed allowable area in Table 503 (if applicable) 7 Note on the plans "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort" Section 1008 1 8 In lieu of the above, in a Group B, F, M or S occupancies (or Group A having an occupant load of 300 or less), you may note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED " This signage is only allowed at the mam exit Carlsbad OS-1877 10/13/O8 DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 U • REMODELS. ADDITIONS AND REPAIRS7 I • When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a The area of specific alteration, repair or addition must comply as "new" construction b A primary entrance to the building and the primary path of travel to the altered area. must be shown to comply with all accessibility features c Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features 8 Provide notes and dimensional details on the plans to show that the existing sanitary facilities, access from the parking to the proposed addition and from the addition to the existing sanitary facilities complies with the disabled access standards FOUNDATION 9 All new additions, require a soils report An update letter is required if the report is more than 3 years old 10 Provide a copy of the project soil report prepared by a licensed civil engineer The report shall include foundation design recommendations based on the engineer's findings 11 In Seismic Design Categories D, E or F, the soils investigation must address liquefaction, and, if retaining walls are proposed, the soils investigation must address increased loading on the walls due to earthquake motions Section 1802 2 7 STRUCTURAL 12 Provide minimum structural specifications on the plans to show that all structural materials will comply with the design calculations and building code requirements Section A106 1 1 13 Provide vertical load calculations for framing members and footings Section A106 1 1 14 Provide lateral load calculations for shear panels, shear transfer and related Section A106 1 1 15 In the seismic calculations, the Site Class must be assumed to be 'D' unless shown otherwise in a geotechnical report Section 1613 5 2 ® Construction documents Carlsbad O8-1877 1O/13/O8 16 The following design loads shall be clearly indicated on the plan construction documents (Section 1603 1) » Wind load The following information should be provided, (Section 1603 1 4) a Basic Wind speed (3-second gust), mph b Wind importance factor, I, and building category c Wind exposure d Applicable internal pressure coefficient • Seismic design data The following information should be provided (Section 1603 1 5) e Seismic importance factor, IE and occupancy category v f Mapped spectral response accelerations Ss and Si g Site class h Spectral response coefficients SDs and SDi i Seismic design category j Basic seismic-force-resisting system(s) k Design base shear I Seismic response coefficient(s), Cs m Response modification factor(s), R n Analysis procedure used • Special Inspection of Materials and Construction 17 The plans shall indicate that special inspection will be provided for the following work (Section A106 1) a Masonry construction Special inspection should be provided for all masonry construction in accordance with Section 1704 5 2 and Table 1704 5 1 (Section 1704 5 2 and Table 1704 5 3) b Steel construction Special inspections for steel elements should be provided in accordance with Section 1704 3 and Table 1704 3 18 Note on the plans that a Statement of Special Inspections, prepared by the registered design professional in responsible charge, shall be submitted This statement shall include a complete list of materials and work requiring special inspection, the inspections to be Carlsbad O8-1877 1O/13/08 performed and an indication whether the special inspection will be continuous or periodic Section 17052 19 Concrete and Masonry Wall Anchorage Anchorage between concrete and masonry walls and floors, roofs, and other structural elements should provide a positive direct connection capable of resisting the horizontal forces specified in Section 1211 1, but not less than a minimum horizontal force of 280 pounds per linear foot of wall Walls should be designed to resist bending between anchors where the anchor spacing exceeds 4 feet (Section 12112) a For SDC C through F, the following additional anchorage provisions apply, per Section 12 11 2 i The out-of-plane force shall satisfy Equation 12 11-1 in Section 121121 i ii Diaphragms shall be provided with continuous ties or struts between diaphragm chords to distribute the anchorage forces into the diaphragms END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you Carlsbad 08-1877 10/13/08 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Chuck Mendenhall PLAN CHECK NO 08-1877 DATE 10/13/08 BUILDING ADDRESS 2045 Corte Del Nogal BUILDING OCCUPANCY F 1 TYPE OF CONSTRUCTION III B BUILDING PORTION machine Rm Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 1000 cb Valuation Multiplier 4545 By Ordinance Reg Mod VALUE (S) 45,450 45,450 $362 01 Plan Check Fee by Ordinance Type of Review ] Repetitive Feer~i Repeats GD Complete Review D Other r—| Hourly Structural Only Hour* $235 31 Esgil Plan Review Fee $202 73 Comments Sheet 1 of 1 macvalue doc City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST DATE BUILDING AD'DR'ESS PROJECT DESCRIPTION PLANCHECK NO CB flff/B'?'? ASSESSOR'S PARCEL NUMBER APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements ENGINEERING DEPARTMENT Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date By FOR OFFICIAL USE ONLY EERING AUTHORIZATION TO ISSUE BUILDING PERMIT D Dedication Application D Dedication Checklist U Improvement Application D Improvement Checklist D Neighborhood Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist and Information Sheet Q Storm water Applicability Checklist Name ENGINEERING DEPT CONTACT PERSON JOANNE JUCHNIEWICZ City of Carlsbad Address 1635 Faraday Avenue Carlsbad, CA 92008 Phone (760) 602-2775 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract • Carlsbad CA 92OO£-7314 • (76O) 6O2-272O • FAX (760) 602^36*2 }RD D D 7 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow B Existing & Proposed Structures C Existing Street Improvements D Property Lines E Easements D 2 Show on site plan F Right-of-Way Width & Adjacent Streets G Driveway widths H Existing or proposed sewer lateral I Existing or proposed water service J Existing or proposed irrigation service A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION F \BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST ,RD DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No D 4b All conditions are in compliance Date DEDICATION REQUIREMENTS 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 7-i x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date n D IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST iST -.ND -,RD ODD checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $430 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows ODD D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy D D D D GRADING PERMIT REQUIREMENTS The conditions that invoke the need for 15 16 010 of the Municipal Code a grading permit are found in Section 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial) This information must be included on the plans 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit D Grading Inspector sign off by Date D 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F (BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST , ST RD3 D D 7d No Grading Permit required 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for D D D D D INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7138, for assistance Industrial Waste permit accepted by Date 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first 10 a STORM WATER COMPLIANCE FORM Q Requires PSWP (project storm water permit) # ier I/Tier II (Requires SWPPP) - Please complete attached forms 'Exempt - Please complete attached exemption form FEES Required fees are attached No fees required F \BUILOINQ PLANCHECK CKLST FORM doc ,ST •>RD D BUILDING PLANCHECK CHECKLIST WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) 12b Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection F \BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLISTST ND RD 3 In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future D D 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this D D D 13 Additional Comments F BUILDING PLANCHECK CKLST FORM doc ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET [mate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal Address Prepared by Blda Perm.t No Checked by Date EDU CALCULATIONS List types and square footages for all uses Types of Use (AdiwJLtKX^/ Sq Ft /Units Types of Use t^^^^^&Sg Ft /Units APT CALCULATIONS List types and square footages for all uses Types of Use t/t4/fr»£/vAjfcy Sq Ft/Units Types of Use /Wv/^~rz«V /^Sq Ft/Units f cflyo EDU's EDU's ADT's . ADT's .3LO 5 FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee)NO PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS/ 2 TRAFFIC IMPACT FEE ADT'S/UNITS 3/ 3 BRIDGE AND THOROUGHFARE FEI ^ ADT's/UNITS (0/ 4 FACILITIES MANAGEMENT FEE X^ UNIT/SO FT f ft 5 SEWER FEE EDU'S i jL& BENEFIT AREA 6^ EDU'S * %0 reSEWER LATERAL ($2,500) ^7 DRAINAGE FEES PLDA ACRES ^8 POTABLE WATER FEES UNITS CODE CONNECTION X FEE/ADT 7 in =$ TU'O E (DIST #1 *S DIST #2 DIST #3 ) X FEE/ADT (3.^ =$ [£I£L/' ZONE 5 X FEE/SO FT /UNIT / ?O =$ 3^6,^ X FEE/EDU /Ol(? =$ &- \5\ . 9- X FEE/EDU /(/'/ =$ <7~^ - ^ =$ 0 / HIGH /LOW X FEE/AC =$ 0 f FEE METER FEE SDCWA FEE SDCWA FEE F \FEE CALCULATION WORKSHEET doc 1 Of 2 Rev 7/14/00 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB081877 DATE 10/2/08 ADDRESS 2045 CORTE DEL NOGAL RESIDENTIAL ADDITION- MINOR (< 17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER EQUIPMENT ENCLOSURE OK BY SCOTT DONNELL PLANNER GINA RUIZ ENGINEER DATE 10/2/08 DATE II \AI]«l\\nil!\TE|l/PL\SMNr,/F.\TI\FI:RIM' APPROVALS Carlsbad Fire Department Plan Review Demerits Category TI, INDUST DateofR4>o/f 12-30-2008 Name Address Reviewed by Permit # CB081877 Job Name 996 SF CMU ENCLOSURE W/ROOF Job Address 2045 CORTE DEL NOGAL CBAD BLDG. DEFT COPY Tnri iFiTF. The itrm ynn hnyn "nbmittrrl fnr rnvmv n inmnirlrtr At this time, this office cannot adequately conduct a review to determine compliance with the apphcabIe^bTre^a!*d4iL§tandards Please review carefully all comments attac ror review and approval Conditions ns~ana/or specmcatior "clouded", Cond CON0003118 [MET] ** APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Deferred submittals for all fire protection systems shall be submitted and approved prior to installation Proof of rated separation that justifies exemption of sprinklers shall be submitted ( cite code section) to Fire Prevention and approved by the Fire Marshal Entry 12/17/2008 By cwong Action AP Cond CON0003223 [MET] Sprinkler omission in mechanical enclosure approved Reference archived plans showing 4HR party wall along with CBC sections 705 1 1, 705 4 705 1 2 Exception and Table 780 1(2) Item #4 Entry 12/30/2008 By cwong Action AP Carlsbad Fire Department IT CO^ Plan Review Requirements Category TI, INDUST Date of Report 12-17-2008 Reviewed by Name MARK SWENSON Address STE 200 6125 CORNERSTONE CT SAN DIEGO CA92121 Permit # CB081877 Job Name 996 SF CMU ENCLOSURE W/ROOF Job Address 2045 CORTE DEL NOGAL CBAD INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions Cond CON0003118 [MET] THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW g3e"fOTed-submittals-forall-fire protectioj^ L__installation ProofLof rated separation_ihat-justifies-exemption.of-sprinkltrs~sHairbe~submitted-(> -cite code"section~)'to~FirF'PfeventioTi^ndapproved"By^rje"Fire"Marshal ~^ Entry 12/17/2008 By cwong Carlsbad Fire Department Plan Review Requirements Category TI , INDUST Date of Report 12-15-2008 Reviewed by Name Address MARK SWENSON STE 200 6125 CORNERSTONE CT SAN DIEGO CA92121 1X5 DEFT COPY Permit # CB081877 Job Name 996 SF CMU ENCLOSURE W/ROOF Job Address 2045 CORTE DEL NOGAL CBAD INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions Cond CON0003118 [MET] ** APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Deferred submittals for all fire protection systems shall be submitted and approved prior to installation Entry 12/15/2008 By cwong Action AP Carlsbad Fire Department Plan Review Requirements Category TI, INDUST Date of Report 10-23-2008 MARK SWENSON Reviewed by ( [jj_A>>fM? / Name Address STE 200 6125 CORNERSTONE CT SAN DIEGO CA92121 •J.DEPT Permit # CB081877 Job Name 996 SF CMU ENCLOSURE W/ROOF Job Address 2045 CORTE DEL NOGAL CBAD INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a revieiV lU'daigrnHH^eampUgnrfl with the annlirabJe-&ode.s and/or standards Please review carefully all comments attactejiBJBie«seui'KBr5mit the"necessaryupraBs^«d4l^E£?1ficatlons' with cnan§8S-'clouded", to this office forjce««C^>andapproval Conditions Cond CON0003118 [MET] ** APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 10/23/2008 By cwong Action AP FAX (619) 263 2995 PHONE (619)234 7966 LICENSE 169 983 omic Investments, Inc. FOUNDED 1956 3200 HIGHLAND AVENUE NATIONAL CITY CAIFORNIA 91950 www atom ic me com 3 April 2009 Will Foss, Building Official City of Carlsbad, Building Department 1635 Faraday Avenue Carlsbad, CA 92008-7314 Re Application for Unreasonable Hardship Exception - Exterior Path of Travel to Entry Permit # CB081877, Existing Exterior CMU Mechanical Enclosure Code Upgrade 2045 Corte del Nogal, Carlsbad, CA Dear Mr Foss Please find enclosed the revised original "Application for Unreasonable Hardship Exception " As a follow up to your most recent email, we are re-submitting this form (with the wet signed signatures of the architect and building owner) to include the upgraded ADA parking (re-striping and ADA signs) With the inclusion of this ADA parking upgrade, the complete ADA work performed in conjunction with the subject permit now represents 53% of the construction costs The required back-up documentation is also enclosed Thank you for your attention to this matter Please let me know if you may anything further to the material you office has received to date in order to complete the hardship application Sincerely, Atomic Investments, Inc Ralph Teyssier Vice President enc F ALLDATA\PROPERTY\P35 2045 Corte del Nogal\\P35 - Cover Ltr to Will Foss - revised ADA Hardship form doc ^rfzajv"' '• City of San Diego /^TSiJ^ Development Services ^— ISffill— ^! 1222 First Ave , MS-302 ygjj&P San Diego CA 92101 ^^^ (61 9) 446-5000THE CITY OF SAN DIEGO Application for Unreasonable Hardship Exception to Disabled Access Requirements FORM DS-21 23 FEBRUARY 2009 Please print legibly or type Project Address2045 Corte del Nogal Carlsbad CA Plan File NumberCB081877 OwnerLeonard & Monica Teyssier Family Trust Telephone Include Area Code (619) 234-7966 (contact Philip Teyssier) ApplicantRafph Teyssier Telephone Include Area Code (310)995-6176 It is requested that the above named project be granted an exception from the accessibility requirements of the 2001 California Buildmg Code, as specifically noted below A Section 1134B General Exception Applicable to existing buildings where the con- struction cost at this tenant space over the last three years does not exceed the valua- tion threshold amount The specific accessibility features that create a hardship may be exempted but not all the accessibility features The area of alteration itself may not be exempted Access Features Does this feature meet the lat- If not, is this feature going If so, cost of making Item. Provide description est edition of Title 249 to be made accessible as feature accessible9 below part of this permit' Attach documentation Valuation threshold Amount $126,764 66Valid until January 2010 no partial (see below) yes N/A N/A Yes (work appr'd 3/05/2009) N/A 1 Path of travel to entrance 2 Entrance 3 Path of travel within building/facility to area of remodel 4 Elevator 5 Sanitary facilities 6 Public Telephones If provided 7 Drinking fountains If provided Nlf\ 8 Other (Parking signage, etc ) Specify Yes Accessible parking Total cost of access features provided (A) Total cost of construction of this project and all other work performed over the last 3 years in this tenant space (B) *Percentage of total cost of project (20% minimum) (A-B) x 100% $ 31 OOP 00 56875 156000 212875 401400 530 Description of access features to be provided Adding accessible items to existing restroom for full accessibility (noted in #5 above) and providing accessible parking signage and rest ripe accessible parking spaces (noted in #8 above) Alterations performed over the last three years in this tenant space Include in total valuation B above unless 20% of valuation of individual remodel has already been expended on access feature (provide documentation) Permit Number Date Description Valuation CB081877 3/05/2009 mech enclosure for code compliance $4010 Odj (see back updoes) Printed on recycled paper Visit our web site at www sandiego gov/development services Upon request this information is available in alternative formats for persons with disabilities 032123(0209) Page 2 of 2 City of San Diego • Development Services Department Disabled Access Unreasonable B Specific Exceptions Do not use this portion if part A has been completed This part is generally used for remodels exceeding the threshold amount and where Title 24 provides an exemption from specific accessibility features Exceptions Requested Code Section/Exception Cost of Making Features Accessible Attach Documentation Total $ Description The cost of all construction contemplated is $ The access feature increases the cost of construction by Percentage of construction cost The impact on financial feasibility of the project, if the requested exception is not approved is The facility is used by the general public for the purpose of The following individuals provided information listed above For City Use Only Date Received Received by Findings and decisions of the Enforcing Official Request Granted General Unreasonable Hardship Exception request is approved based on Section 1134B 2 1 of the California Building Code Access features listed in part A of this form shall be provided as part of this permit LJ Specific Exception(s) request is approval based on Section(s)_ shall be provided as specified in the California Building Code All other access features *-—! Ratification required This decision must be ratified by the Board of Building Appeals and Advisors An application must be completed and a filing fee paid before the board can hear the request LJ Request denied If you disagree with this determination, you may seek an appeal through the Board of Building Appeals and Advisors ^_J An application must be completed and a filing fee paid before the board can hear the request Name of enforcing official Please print Signature of enforcing official Date niurn.iLij) j* /jtui in N j ii urn omlc Investments* Inc. SHEET NO 1 of 1 J 1W HlttHLJWU AVLNL'L NAIIUNAI UIV UUIUifMA Jt JiU PROJECT NO DATE P35 200901 2009-04 01 PROJECT 2045 Corte del Nogal, Carlsbad SUBJECT Construction Costs for ADA Parking Upgrade BY RJT CHECKED BY.PLT Construction Costs for ADA Parking Upgrade - WORK COMPLETED 2009-04-01 Item No Description Quan Sub-contract - American Asphalt and Concrete Inc Black-out existing markings, power clean & apply sealer, stripe Install 2 handicap signs with posts I I i Unit Unit cost Lump Sum Subtotal 1 $1 260 00 $300 00 I j Subtotal j II '! $1,56000 03/31/2009 04 08 FAX 16195898113 AMERICAN A/C AMERICAN ASPHALT AND CONCRETE, INC. 9011 MEMORY LANE SPRING VALLEY, CA 91977-2152 Ph (619)589-8112 * Fax (619)589-8113 CA License No 688323 PROPOSAL / CONTRACT NAME/ADDRESS ATOMIC iNVCSTMEN-iS, INC 3200 B4-2 HIGHLAND AVtMUE NATIONAL CITY CA 91950 TERMS NET UPON COMPLETION REP or AMERICAN Asphalt & Concrete, inc. DATE 3/26/2009 ESTIMATE No 8708 PROJECT 2045 COR f£ DE NOGAL PHONE NUMBERS OFF/619-23^-7966 FAX/619-263-2995 DESCRIPTION TOTAL 1 BLACK OUT EXISTING UXiO 2 POWER CLEAN AND APPLY ONE COAT OF FMULSION StAL TO ASPHALT TOTALING APPR.OX 4500 S F 3 STRIVE AS PCR PLAN (ITEMS 1 3 ONLY) 4 INSTALL (2) HANDICAP SIGNS WITH POSTS (ITEM 4 ONLY) 1,26000 30000 I'HANK YOU FOR THIS OPPORTUNITY TO BID YOUR PROJECT TOTAL $1,560 oo D TO BE MEASURED ON COMPLETION AND INVOICED AT UNIT PRICES D Mot responsible for reflective cracking thru overlays & skin patching D Not responsible for weed growth from adjacent property D Crack filling does not imply crack repair D Not responsible for pre-existing subgrade AMERICAN ASPHALT AND CONCRETE, INC. Q Not responsible for pre-existing engineering with respect to drainage D Not responsible for beck-fill and compaction or back nil installed by others D Engineering testing, inspection and permit fees not included Q Not responsible for underground utilities in areas to be removed By CUSTOMER ACCEPTANCE CREQTYNER I/We accept the within proposal and agree to pay the said amount In accordance with the terms set forth All of the terms and definitions on the reverse aide are Incorporated herein and made a part hereof. Company Customer Signature _Date Customer #_ White Contractor's Copy * Yellow Customer's Copy * Pink Office Copy * Blue Log Copy RALPH TEVSSIER 162 NORTH SYCAMORE AVENLE Los ANGELES, CALIFORNIA 90036 1 December 2008 Mr Will Foss, Chief Building Official CITY OF CARLSBAD, Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Re Letter of Certification of Existing Mechanical Enclosure at 2045 Corte del Nogal, Carlsbad, CA Dear Mr Foss As requested by the City of Carlsbad, architectural and structural drawings have been prepared and submitted to the Building Department for the existing mechanical enclosure located at the above referenced address I serve as the Structural Engineer of Record and have prepared calculations with the drawing submittal package Further, as a requirement to waive special inspection of the enclosure's CMU wall screen, I have performed a review of the subject walls I find that the enclosure walls, in addition to all the other structural framing components, substantially meets the general structural intent of the building code Sincerely, Ralph Teyssier, S E CALic S3727 S3727 EXP 12/31/2009 cc Mr Mark Swenson, AIA, Architect, Studio C Architects