HomeMy WebLinkAbout2045 CORTE DEL NOGAL; ; CB081877; Permit12-31-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB081877
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
2045 CORTE DEL NOGAL CBAD
Tl Sub Type
2130610900 Lot#
$45,450 00 Construction Type
Reference #
996 SF CMU ENCLOSURE W/ROOF
FOR MECHANICAL EQUIPMENT-NO TENNANT
INDUST
0
5B
Applicant
MARK SWENSON
STE 200
6125 CORNERSTONE CT 92121
858 866-0889
Status ISSUED
Applied 10/02/2008
Entered By RMA
Plan Approved 12/31/2008
Issued 12/31/2008
Inspect Area
Plan Check*
Owner
TEYSSIER L&M FAMILY TRUST 10-14-92
C/0 ATOMIC INVESTMENTS
3200 B4-2 HIGHLAND AVE
NATIONAL CITY CA 91950
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
Green Bldg Stands (SB1473) Fee
$392 28 Meter Size
$0 00 Add'l Reel Water Con Fee
$254 98 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$954 PFF (3105540)
$398 40 PFF (4305540)
$000 License Tax (3104193)
$132 00 License Tax (4304193)
$000 Traffic Impact Fee (3105541)
$0 00 Traffic Impact Fee (4305541)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
7? HMP Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$249 60
$230 40
$000
$000
$000
$000
$244 60
$000
$000
79
$1,911 80
Total Fees $1,911 80 Total Payments To Date
n.i
$1,911 80 Balance Due
PI A "MS,
$000
IN STORAGE
ATTACHED
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations or other exactions hereafter collectively
referred to as lees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required 'nformation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to watei and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which von have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
1635 Faraday Ave , Carlsbad, CA 92008
760-602-2717 / 2718 / 2719
Fax 760-602-8558
www carlsbadca gov
Building Permit Application
JOB ADDRESS SUITE#/SPACE#/UNIT#
CT/PROJECT*LOT*PHASE tf tt OF UNITS # BEDROOMS # BATHROOMS
DESCRIPTION OF WORK Include Square Feet of Affected Area(s)
Room
tftf/
EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE
YES D #NO D
AIR CONDITIONING
YES D NO D
FIRE SPRINKLERS
YES D NO D
CONTACT NAME (If Different Font Applicant)APPLICANT NAME
ADDRESS ADDRESS
CITY STATE ZIP ZIP
PHONE FAX -ojy?
EMAIL EMAIL
PROPERTY OWN^R NAMEf /MONICA CONTRACTOR BUS NAME
ADDRESS
CITY 3d ZIP
1I1SV CITY STATE ZIP
PHONE FAX
EMAIL EMAIL
ARCH/DESIGNER NAME & ADDRESS CLASS CITY BUS LIC #
[Sec. 70315 Business andlicensed oursuant to th
Section 70315 by any
less and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is
to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that lie is exempt therefrom, ind cite basis For the alleged exemption Any violation of1 any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500})
S^S^S^S^^E^
Workers' Compensation Declaration / hereby affirm under penally ol perjury one of the following declarations
L~J I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued
G I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers' compensation insurance earner and policy
number are Insurance Co ___ Policy No _ Expiration Date _
section need not be completed if the permit is for one hundred dollars ($100) or less
Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&1 00,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees
JS$ CONTRACTOR SIGNATURE DATE
/ hereby affirm that I am exempt from Contractor's License Law lor the following reason
fS(j I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's
bcense Law does not apply to an owner of property who builds or improves thereon, and who does such work himsell or through his own employees, provided that such improvements are not intended or offered for
sale If however the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law)
D I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O Yes D No
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have_C2ntracted with the following person (firm) lo provide the proposed construction (include name address / phone / contractors' license number)
4 kjfan to providS portions oMne work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors license number)
«I v ill prowis-soine ol the^voijj^it I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work)
/I I /1,
Is the applicant or future building occupant required to submit a business plan^acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley Tanner Hazardous Substance Account Act9 D Yes Sfno
Is the applicant or future building occupant required to obtain a permit Irom the air pollution control district or air quality management district7 CJ Yes 3-NiT
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site7 D Yes
IF ANY OF THE ANSWERS ARE YES, /
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code)
Lender's Name ^ | 1 Lender's Address ill
I certify that I have read the application and slate that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CfTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit B required for excavations over 5'0' deep and demolition or construction of structures over 3 stones m height
EXPIRATION Every permit issued by the Building Official under the provisions of the Code shall expire by limitation and become null and void if the building or work authorized by such permit B not commenced within
1 80 days from the date of such permit or if the buJHlhg or work authorized by such perml B suspended or abandoned at any time after the work s commenced for a period of J80 days (Section 1 06 4 4 Uniform Building Code)
^APPLICANT'S SIGNATURE /^ Ij DATE
UNSCHEDULED BUILDING INSPECTION
DATE <//?/o4 INSPECTOR
PERMIT # C6&0/877 PLAN CHECK #
JOB ADDRESS -Zc*s<T /gacre fftt
DESCRIPTION
CODE DESCRIPTION ACT COMMENTS
Inspection List
Permit* CB081877
Date Inspection [tern
04/07/2009 89 Final Combo
03/04/200919 Final Structural
Type Tl INDUST
03/04/2009 92
03/02/2009 19
03/02/2009 19
Compliance Investigation
Final Structural
Final Structural
Inspector
TP
TP
TP
Act
AP
CO
Rl
Rl
CO
996 SF CMU ENCLOSURE W/ROOF
FOR MECHANICAL EQUIPMENT-NO TENN
Comments
BLDG ACCESSABLE PARKING & ROUTE
TO BLDG
ADA COMPLIANCE - LATE MORNING
PM 12-1
Wednesday, April 08, 2009 Page 1 of 1
City of Carlsbad Bldg Inspection Request
For 03/04/2009
Permit* CB081 877 Inspector Assignment TP
Title 996 SF CMU ENCLOSURE W/ROOF
Description FOR MECHANICAL EQUIPMENT-NO TENNANT
Type Tl Sub Type INDUS!
Phone 3109956176
Job Address 2045 CORTE DEL NOGAL
Suite Lot 0
Location Inspector
OWNER TEYSSIERL&M FAMILY TRUST 10-14-92
Owner TEYSSIER L&M FAMILY MARITAL TRUST 10-14-92
Remarks ADA COMPLIANCE - LATE MORNING
Total Time _ Requested By CONTRACTOR
Entered By CHRISTINE
CD Description Act Comments
9? Compliance Investigation fa
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
CV030273 CLOSED H- CONSTRUCTION W/OUTPERMIT,
CV080321 CLOSED Z- BUSINESS LICENSE DENIED,
CV080374 OPEN II- ILLEGAL CONSTRUCTION,
PCR03094 EXPIRED SEASII.VER REVELECSCII.
PCR03100 EXPIRED SEASILVER-Dni-' SUBMIT-REV A. TANKS-SESMIC & CONNECTIONS
Inspection History
Date Description Act Insp Comments
EsGil Corporation
In (Partnership with government for (Buihfing Safety
DATE 12/10/08
JURISDICTION Carlsbad
PLAN CHECK NO 08-1877 SET II
PROJECT ADDRESS 2045 Corte Del Nogal
PROJECT NAME New Mechanical Equipment Room
Q PLAN REVIEWER
Q FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
[X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department
staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
X] Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted
Date contacted
Mail Telephone
(by )
Fax In Person
REMARKS City staff to verify fi
without automatic fire sprinklers
By Chuck Mendenhall
Esgil Corporation
D GA D MB D EJ PC
Telephone #
Fax #
approval of the mechanical equipment enclosure
Enclosures
12/3/08
EsGil Corporation
In (Partnership with government for (Buifcfing Safety
DATE 10/13/08
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 08-1877 SET I
PROJECT ADDRESS 2045 Corte Del Nogal
PROJECT NAME New Mechanical Equipment Room
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
X] The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Mark Swenson, Studio 'C'
6125 Cornerstone Ct, #200, San Diego, CA 92121
Esgil Corporation staff did not advise the applicant that the plan check has been completed
X] Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Mark Swenson Telephone # (858) 866-0889
Date contacted ,c('2/c$-(by ,-A-) Fax # (858)866-0868
Mail - Telephone Fax./ In Person
REMARKS
By Chuck Mendenhall Enclosures
Esgil Corporationn GA n MB n EJ n PC 10/6/08
9320 Chesapeake Drive, Suite 208 ^ San Diego, California 92123 0 (858)560-1468 ^ Fa\ (858) 560-1576
Carlsbad 08-1877
10/13/08
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK NO 08-1877
OCCUPANCY Fl
TYPE OF CONSTRUCTION III B
JURISDICTION Carlsbad
USE Machinery Room
ACTUAL AREA 996
ALLOWABLE FLOOR AREA Unknown STORIES one
SPRINKLERS'? No
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED 10/13/O8
HEIGHT 12'-6" approx per IBC
OCCUPANT LOAD 5
DATE PLANS RECEIVED BY
ESGIL CORPORATION 10/6/08
PLAN REVIEWER Chuck Mendenhall
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled This plan
review is based on regulations enforced by the Building Department You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments Clearance from those departments may be
required prior to the issuance of a building permit
Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of
the 2006 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans
Carlsbad O8-1877
10/13/O8
Please make all corrections, as requested in the correction list Submit three new complete sets
of plans for commercial/industrial projects (two sets of plans for residential projects) For
expeditious processing, corrected sets can be submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will
route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire
Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining
sets of plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete
1 The occupancy classification listed on the cover sheet is 'U' occupancy The proposed is an
equipment machinery room and must be classified as an F-1 occupancy per CBC 306 1
2 The cover sheet lists the building construction as type VB and not sprmklered Provide an area
analysis of the existing building as type VB construction and no sprinklers to show the existing
plus added area is allowed per CBC Table 503
3 Automatic sprinklers are required for buildings having an aggregate floor area of 5,000 sq ft or
more Existing buildings in which the aggregate floor area is expanded and exceeds 5,000
square feet shall be provided with fire sprinklers City ordinance
4 What type of mechanical machinery will be installed within this machine room Will there be
refrigeration equipment? Will there be boilers9 Note that boilers may not be located within a
refrigeration (chiller) room
5 The machinery room for boilers and /or refrigeration equipment must be separated from the
remainder of the building per Table 508 2 It appears that the existing tilt up concrete wall is
sufficient However, openings for doors and or ducts passing through the wall must compOly with
CBC Section 706 7
6 Provide a Building Code Data Legend on the Title Sheet Include the following code
information for each building proposed
° Occupancy Classification(s)
« Description of Use
o Justification to exceed allowable area in Table 503 (if applicable)
7 Note on the plans "All egress doors shall be readily openable from the egress side without the
use of a key or special knowledge or effort" Section 1008 1 8 In lieu of the above, in a
Group B, F, M or S occupancies (or Group A having an occupant load of 300 or less), you may
note on the plans "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN
UNLOCKED WHEN BUILDING IS OCCUPIED " This signage is only allowed at the mam exit
Carlsbad OS-1877
10/13/O8
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
U • REMODELS. ADDITIONS AND REPAIRS7
I
• When alterations, structural repairs or modifications or additions are made to an existing
building, that building, or portion of the building affected, is required to comply with all of the
requirements for new buildings, per Section 1134B 2 These requirements apply as follows
a The area of specific alteration, repair or addition must comply as "new" construction
b A primary entrance to the building and the primary path of travel to the altered area.
must be shown to comply with all accessibility features
c Existing sanitary facilities that serve the remodeled area must be shown to comply with all
accessibility features
8 Provide notes and dimensional details on the plans to show that the existing sanitary facilities,
access from the parking to the proposed addition and from the addition to the existing sanitary
facilities complies with the disabled access standards
FOUNDATION
9 All new additions, require a soils report An update letter is required if the report is more than 3
years old
10 Provide a copy of the project soil report prepared by a licensed civil engineer The report shall
include foundation design recommendations based on the engineer's findings
11 In Seismic Design Categories D, E or F, the soils investigation must address liquefaction, and,
if retaining walls are proposed, the soils investigation must address increased loading on the
walls due to earthquake motions Section 1802 2 7
STRUCTURAL
12 Provide minimum structural specifications on the plans to show that all structural materials will
comply with the design calculations and building code requirements Section A106 1 1
13 Provide vertical load calculations for framing members and footings Section A106 1 1
14 Provide lateral load calculations for shear panels, shear transfer and related Section
A106 1 1
15 In the seismic calculations, the Site Class must be assumed to be 'D' unless shown otherwise
in a geotechnical report Section 1613 5 2
® Construction documents
Carlsbad O8-1877
1O/13/O8
16 The following design loads shall be clearly indicated on the plan construction documents
(Section 1603 1)
» Wind load The following information should be provided, (Section 1603 1 4)
a Basic Wind speed (3-second gust), mph
b Wind importance factor, I, and building category
c Wind exposure
d Applicable internal pressure coefficient
• Seismic design data The following information should be provided (Section 1603 1 5)
e Seismic importance factor, IE and occupancy category v
f Mapped spectral response accelerations Ss and Si
g Site class
h Spectral response coefficients SDs and SDi
i Seismic design category
j Basic seismic-force-resisting system(s)
k Design base shear
I Seismic response coefficient(s), Cs
m Response modification factor(s), R
n Analysis procedure used
• Special Inspection of Materials and Construction
17 The plans shall indicate that special inspection will be provided for the following work (Section
A106 1)
a Masonry construction Special inspection should be provided for all masonry
construction in accordance with Section 1704 5 2 and Table 1704 5 1 (Section 1704 5 2
and Table 1704 5 3)
b Steel construction Special inspections for steel elements should be provided in
accordance with Section 1704 3 and Table 1704 3
18 Note on the plans that a Statement of Special Inspections, prepared by the registered design
professional in responsible charge, shall be submitted This statement shall include a
complete list of materials and work requiring special inspection, the inspections to be
Carlsbad O8-1877
1O/13/08
performed and an indication whether the special inspection will be continuous or periodic
Section 17052
19 Concrete and Masonry Wall Anchorage Anchorage between concrete and masonry walls
and floors, roofs, and other structural elements should provide a positive direct connection
capable of resisting the horizontal forces specified in Section 1211 1, but not less than a
minimum horizontal force of 280 pounds per linear foot of wall Walls should be designed to
resist bending between anchors where the anchor spacing exceeds 4 feet (Section 12112)
a For SDC C through F, the following additional anchorage provisions apply, per Section
12 11 2
i The out-of-plane force shall satisfy Equation 12 11-1 in Section 121121
i
ii Diaphragms shall be provided with continuous ties or struts between diaphragm
chords to distribute the anchorage forces into the diaphragms
END OF REVIEW
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contact Chuck Mendenhall at Esgil Corporation Thank you
Carlsbad 08-1877
10/13/08
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Chuck Mendenhall
PLAN CHECK NO 08-1877
DATE 10/13/08
BUILDING ADDRESS 2045 Corte Del Nogal
BUILDING OCCUPANCY F 1 TYPE OF CONSTRUCTION III B
BUILDING
PORTION
machine Rm
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
1000
cb
Valuation
Multiplier
4545
By Ordinance
Reg
Mod
VALUE (S)
45,450
45,450
$362 01
Plan Check Fee by Ordinance
Type of Review
] Repetitive Feer~i Repeats
GD Complete Review
D Other
r—| Hourly
Structural Only
Hour*
$235 31
Esgil Plan Review Fee $202 73
Comments
Sheet 1 of 1
macvalue doc
City of Carlsbad
Public Works — Engineering
BUILDING PLANCHECK CHECKLIST
DATE
BUILDING AD'DR'ESS
PROJECT DESCRIPTION
PLANCHECK NO CB flff/B'?'?
ASSESSOR'S PARCEL NUMBER
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal, therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached as failure to comply
with instructions in this report can result in
suspension of permit to build
D A Right-of-Way permit is required prior to
construction of the following improvements
ENGINEERING DEPARTMENT
Please see the attached report of deficiencies
marked with D Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
By
By
By
Date
Date
Date
By
FOR OFFICIAL USE ONLY
EERING AUTHORIZATION TO ISSUE BUILDING PERMIT
D Dedication Application
D Dedication Checklist
U Improvement Application
D Improvement Checklist
D Neighborhood Improvement Agreement
D Grading Permit Application
D Grading Submittal Checklist
D Right-of-Way Permit Application
[] Right-of-Way Permit Submittal Checklist
and Information Sheet
Q Storm water Applicability Checklist
Name
ENGINEERING DEPT CONTACT PERSON
JOANNE JUCHNIEWICZ
City of Carlsbad
Address 1635 Faraday Avenue Carlsbad, CA 92008
Phone (760) 602-2775
CFD INFORMATION
Parcel Map No
Lots
Recordation
Carlsbad Tract
• Carlsbad CA 92OO£-7314 • (76O) 6O2-272O • FAX (760) 602^36*2
}RD
D D
7
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
A North Arrow
B Existing & Proposed Structures
C Existing Street Improvements
D Property Lines
E Easements
D 2 Show on site plan
F Right-of-Way Width & Adjacent Streets
G Driveway widths
H Existing or proposed sewer lateral
I Existing or proposed water service
J Existing or proposed irrigation service
A Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
B Existing & Proposed Slopes and Topography
C Size, type, location, alignment of existing or proposed sewer and water service (s)
that serves the project Each unit requires a separate service, however, second
dwelling units and apartment complexes are an exception
D Sewer and water laterals should not be located within proposed driveways, per
standards
3 Include on title sheet
A Site address
B Assessor's Parcel Number
C Legal Description
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
F \BUILDING PLANCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLIST
,RD DISCRETIONARY APPROVAL COMPLIANCE
4a Project does not comply with the following Engineering Conditions of approval for
Project No
D 4b All conditions are in compliance Date
DEDICATION REQUIREMENTS
5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
dram or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 7-i x 11" plat map and
submit with a title report All easement documents must be approved and signed
by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist for the dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
n D
IMPROVEMENT REQUIREMENTS
6a All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section
1840040
Public improvements required as follows
Attached please find an application form and submittal checklist for the public
improvement requirements A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process The completed application form and the requirements on the
F \BUILDING PLANCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLIST
iST -.ND -,RD
ODD
checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by Date
6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $430 so we may
prepare the necessary Neighborhood Improvement Agreement This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit
Future public improvements required as follows
ODD
D D
6c Enclosed please find your Neighborhood Improvement Agreement Please return
agreement signed and notarized to the Engineering Department
Neighborhood Improvement
Agreement completed by
Date
6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
D D D
D
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for
15 16 010 of the Municipal Code
a grading permit are found in Section
7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities in cubic yards (cut, fill, import,
export and remedial) This information must be included on the plans
7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
D
Grading Inspector sign off by Date
D 7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required )
F (BUILDING PLANCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLIST
, ST RD3
D
D
7d No Grading Permit required
7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tying
into public storm dram, sewer and water utilities
Right-of-Way permit required for
D D
D D
D
INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 7138,
for assistance
Industrial Waste permit accepted by
Date
10 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
10 a STORM WATER COMPLIANCE FORM
Q Requires PSWP (project storm water permit) #
ier I/Tier II (Requires SWPPP) - Please complete attached forms
'Exempt - Please complete attached exemption form
FEES
Required fees are attached
No fees required
F \BUILOINQ PLANCHECK CKLST FORM doc
,ST •>RD
D
BUILDING PLANCHECK CHECKLIST
WATER METER REVIEW
12a Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized
Oversized meters are inaccurate during low-flow conditions If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used
• All single family dwelling units received "standard" 1" service with 5/8" service
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations, which
include total fixture counts and maximum water demand in gallons per minute
(gpm) A typical fixture count and water demand worksheet is attached Once
the gpm is provided, check against the "meter sizing schedule" to verify the
anticipated meter size for the unit
• Maximum service and meter size is a 2" service with a 2" meter
• If a developer is proposing a meter greater than 2", suggest the installation of
multiple 2" services as needed to provide the anticipated demand (manifolds
are considered on case by case basis to limit multiple trenching into the
street)
12b Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior to
approval The developer must provide these calculations Please follow these
guidelines
1 If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets If so, at the water meter station, the demand in
gpm may be listed there Irrigation services are listed with a circled "I",
and potable water is typically a circled "W" The irrigation service should
look like
STA 1+00 Install 2" service and
5 meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach) Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use Once
you have received a good example of irrigation calculations, keep a set for
your reference In general the calculations will include
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
F \BUILDING PLANCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLISTST ND RD
3 In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA) As long as the project is located within the City recycled water
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future
D D 12c Irrigation Use (where recycled water is available)
1 Recycled water meters are sized the same as the irrigation meter above
2 If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development For
subdivisions, this should have been identified, and implemented on the
improvement plans Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this
D D D 13 Additional Comments
F BUILDING PLANCHECK CKLST FORM doc
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
[mate based on unconfirmed information from applicant
Calculation based on building plancheck plan submittal
Address
Prepared by
Blda Perm.t No
Checked by Date
EDU CALCULATIONS List types and square footages for all uses
Types of Use (AdiwJLtKX^/ Sq Ft /Units
Types of Use t^^^^^&Sg Ft /Units
APT CALCULATIONS List types and square footages for all uses
Types of Use t/t4/frȣ/vAjfcy Sq Ft/Units
Types of Use /Wv/^~rz«V /^Sq Ft/Units
f cflyo
EDU's
EDU's
ADT's .
ADT's
.3LO
5
FEES REQUIRED
WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee)NO
PARK-IN-LIEU FEE
FEE/UNIT
PARK AREA & #
X NO UNITS/
2 TRAFFIC IMPACT FEE
ADT'S/UNITS 3/
3 BRIDGE AND THOROUGHFARE FEI
^ ADT's/UNITS (0/
4 FACILITIES MANAGEMENT FEE
X^ UNIT/SO FT f ft
5 SEWER FEE
EDU'S i jL&
BENEFIT AREA 6^
EDU'S * %0
reSEWER LATERAL ($2,500)
^7 DRAINAGE FEES PLDA
ACRES
^8 POTABLE WATER FEES
UNITS CODE CONNECTION
X FEE/ADT 7 in =$ TU'O
E (DIST #1 *S DIST #2 DIST #3 )
X FEE/ADT (3.^ =$ [£I£L/'
ZONE 5
X FEE/SO FT /UNIT / ?O =$ 3^6,^
X FEE/EDU /Ol(? =$ &- \5\ . 9-
X FEE/EDU /(/'/ =$ <7~^ - ^
=$ 0
/
HIGH /LOW
X FEE/AC =$ 0
f
FEE METER FEE SDCWA FEE SDCWA FEE
F \FEE CALCULATION WORKSHEET doc
1 Of 2
Rev 7/14/00
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB081877 DATE 10/2/08
ADDRESS 2045 CORTE DEL NOGAL
RESIDENTIAL ADDITION-
MINOR (< 17,000.00)
RETAINING WALL
VILLAGE FAIRE
POOL/SPA
TENANT IMPROVEMENT
COMPLETE OFFICE BUILDING
OTHER EQUIPMENT ENCLOSURE OK BY SCOTT DONNELL
PLANNER GINA RUIZ
ENGINEER
DATE 10/2/08
DATE
II \AI]«l\\nil!\TE|l/PL\SMNr,/F.\TI\FI:RIM' APPROVALS
Carlsbad Fire Department
Plan Review Demerits Category TI, INDUST
DateofR4>o/f 12-30-2008
Name
Address
Reviewed by
Permit # CB081877
Job Name 996 SF CMU ENCLOSURE W/ROOF
Job Address 2045 CORTE DEL NOGAL CBAD
BLDG. DEFT COPY
Tnri iFiTF. The itrm ynn hnyn "nbmittrrl fnr rnvmv n inmnirlrtr At this time, this office cannot
adequately conduct a review to determine compliance with the apphcabIe^bTre^a!*d4iL§tandards Please review
carefully all comments attac
ror review and approval
Conditions
ns~ana/or specmcatior "clouded",
Cond CON0003118
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Deferred submittals for all fire protection systems shall be submitted and approved prior to
installation Proof of rated separation that justifies exemption of sprinklers shall be submitted (
cite code section) to Fire Prevention and approved by the Fire Marshal
Entry 12/17/2008 By cwong Action AP
Cond CON0003223
[MET]
Sprinkler omission in mechanical enclosure approved Reference archived plans showing 4HR party
wall along with CBC sections 705 1 1, 705 4 705 1 2 Exception and Table 780 1(2) Item #4
Entry 12/30/2008 By cwong Action AP
Carlsbad Fire Department
IT CO^
Plan Review Requirements Category TI, INDUST
Date of Report 12-17-2008 Reviewed by
Name MARK SWENSON
Address
STE 200
6125 CORNERSTONE CT
SAN DIEGO CA92121
Permit # CB081877
Job Name 996 SF CMU ENCLOSURE W/ROOF
Job Address 2045 CORTE DEL NOGAL CBAD
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards Please review
carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval
Conditions
Cond CON0003118
[MET]
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
g3e"fOTed-submittals-forall-fire protectioj^
L__installation ProofLof rated separation_ihat-justifies-exemption.of-sprinkltrs~sHairbe~submitted-(>
-cite code"section~)'to~FirF'PfeventioTi^ndapproved"By^rje"Fire"Marshal ~^
Entry 12/17/2008 By cwong
Carlsbad Fire Department
Plan Review Requirements Category TI , INDUST
Date of Report 12-15-2008 Reviewed by
Name
Address
MARK SWENSON
STE 200
6125 CORNERSTONE CT
SAN DIEGO CA92121 1X5 DEFT COPY
Permit # CB081877
Job Name 996 SF CMU ENCLOSURE W/ROOF
Job Address 2045 CORTE DEL NOGAL CBAD
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards Please review
carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval
Conditions
Cond CON0003118
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Deferred submittals for all fire protection systems shall be submitted and approved prior to
installation
Entry 12/15/2008 By cwong Action AP
Carlsbad Fire Department
Plan Review Requirements Category TI, INDUST
Date of Report 10-23-2008
MARK SWENSON
Reviewed by ( [jj_A>>fM? /
Name
Address
STE 200
6125 CORNERSTONE CT
SAN DIEGO CA92121 •J.DEPT
Permit # CB081877
Job Name 996 SF CMU ENCLOSURE W/ROOF
Job Address 2045 CORTE DEL NOGAL CBAD
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a revieiV lU'daigrnHH^eampUgnrfl with the annlirabJe-&ode.s and/or standards Please review
carefully all comments attactejiBJBie«seui'KBr5mit the"necessaryupraBs^«d4l^E£?1ficatlons' with cnan§8S-'clouded",
to this office forjce««C^>andapproval
Conditions
Cond CON0003118
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Entry 10/23/2008 By cwong Action AP
FAX (619) 263 2995
PHONE (619)234 7966
LICENSE 169 983
omic Investments, Inc.
FOUNDED 1956 3200 HIGHLAND AVENUE
NATIONAL CITY CAIFORNIA 91950
www atom ic me com
3 April 2009
Will Foss, Building Official
City of Carlsbad, Building Department
1635 Faraday Avenue
Carlsbad, CA 92008-7314
Re Application for Unreasonable Hardship Exception - Exterior Path of Travel to Entry
Permit # CB081877, Existing Exterior CMU Mechanical Enclosure Code Upgrade
2045 Corte del Nogal, Carlsbad, CA
Dear Mr Foss
Please find enclosed the revised original "Application for Unreasonable Hardship Exception "
As a follow up to your most recent email, we are re-submitting this form (with the wet signed
signatures of the architect and building owner) to include the upgraded ADA parking (re-striping
and ADA signs) With the inclusion of this ADA parking upgrade, the complete ADA work
performed in conjunction with the subject permit now represents 53% of the construction costs
The required back-up documentation is also enclosed
Thank you for your attention to this matter Please let me know if you may anything further to
the material you office has received to date in order to complete the hardship application
Sincerely,
Atomic Investments, Inc
Ralph Teyssier
Vice President
enc
F ALLDATA\PROPERTY\P35 2045 Corte del Nogal\\P35 - Cover Ltr to Will Foss - revised ADA Hardship form doc
^rfzajv"' '• City of San Diego
/^TSiJ^ Development Services
^— ISffill— ^! 1222 First Ave , MS-302
ygjj&P San Diego CA 92101
^^^ (61 9) 446-5000THE CITY OF SAN DIEGO
Application for
Unreasonable Hardship Exception
to Disabled Access Requirements
FORM
DS-21 23
FEBRUARY 2009
Please print legibly or type
Project Address2045 Corte del Nogal Carlsbad CA Plan File NumberCB081877
OwnerLeonard & Monica Teyssier Family Trust Telephone Include Area Code
(619) 234-7966 (contact Philip Teyssier)
ApplicantRafph Teyssier Telephone Include Area Code
(310)995-6176
It is requested that the above named project be granted an exception from the accessibility requirements of the 2001 California
Buildmg Code, as specifically noted below
A Section 1134B General Exception Applicable to existing buildings where the con-
struction cost at this tenant space over the last three years does not exceed the valua-
tion threshold amount The specific accessibility features that create a hardship may be
exempted but not all the accessibility features The area of alteration itself may not be
exempted
Access Features Does this feature meet the lat- If not, is this feature going If so, cost of making
Item. Provide description est edition of Title 249 to be made accessible as feature accessible9
below part of this permit' Attach documentation
Valuation threshold Amount
$126,764 66Valid until January 2010
no partial (see below)
yes
N/A
N/A
Yes (work appr'd 3/05/2009)
N/A
1 Path of travel to entrance
2 Entrance
3 Path of travel within
building/facility to
area of remodel
4 Elevator
5 Sanitary facilities
6 Public Telephones If provided
7 Drinking fountains If provided Nlf\
8 Other (Parking signage, etc ) Specify Yes Accessible parking
Total cost of access features provided (A)
Total cost of construction of this project and all other work performed
over the last 3 years in this tenant space (B)
*Percentage of total cost of project (20% minimum) (A-B) x 100%
$ 31 OOP 00
56875
156000
212875
401400
530
Description of access features to be provided
Adding accessible items to existing restroom for full accessibility (noted in #5 above) and providing accessible parking signage
and rest ripe accessible parking spaces (noted in #8 above)
Alterations performed over the last three years in this tenant space Include in total valuation B above unless 20% of valuation
of individual remodel has already been expended on access feature (provide documentation)
Permit Number Date Description Valuation
CB081877 3/05/2009 mech enclosure for code compliance $4010 Odj (see back updoes)
Printed on recycled paper Visit our web site at www sandiego gov/development services
Upon request this information is available in alternative formats for persons with disabilities
032123(0209)
Page 2 of 2 City of San Diego • Development Services Department Disabled Access Unreasonable
B Specific Exceptions Do not use this portion if part A has been completed
This part is generally used for remodels exceeding the threshold amount and where Title 24 provides an exemption from
specific accessibility features
Exceptions Requested Code Section/Exception Cost of Making Features
Accessible Attach Documentation
Total $
Description
The cost of all construction contemplated is $
The access feature increases the cost of construction by Percentage of construction cost
The impact on financial feasibility of the project, if the requested exception is not approved is
The facility is used by the general public for the purpose of
The following individuals provided information listed above
For City Use Only
Date Received Received by
Findings and decisions of the Enforcing Official
Request Granted
General Unreasonable Hardship Exception request is approved based on Section 1134B 2 1 of the California Building Code
Access features listed in part A of this form shall be provided as part of this permit
LJ Specific Exception(s) request is approval based on Section(s)_
shall be provided as specified in the California Building Code
All other access features
*-—! Ratification required This decision must be ratified by the Board of Building Appeals and Advisors An application must
be completed and a filing fee paid before the board can hear the request
LJ Request denied If you disagree with this determination, you may seek an appeal through the Board of Building Appeals
and Advisors
^_J An application must be completed and a filing fee paid before the board can hear the request
Name of enforcing official Please print Signature of enforcing official Date
niurn.iLij) j* /jtui in N j ii urn
omlc Investments* Inc.
SHEET NO 1 of 1
J 1W HlttHLJWU AVLNL'L
NAIIUNAI UIV UUIUifMA Jt JiU
PROJECT NO
DATE
P35 200901
2009-04 01
PROJECT 2045 Corte del Nogal, Carlsbad
SUBJECT Construction Costs for ADA Parking Upgrade
BY RJT
CHECKED BY.PLT
Construction Costs for ADA Parking Upgrade - WORK COMPLETED 2009-04-01
Item
No
Description Quan
Sub-contract - American Asphalt and Concrete Inc
Black-out existing markings, power clean & apply sealer, stripe
Install 2 handicap signs with posts
I
I
i
Unit Unit
cost
Lump
Sum Subtotal
1
$1 260 00
$300 00
I
j
Subtotal
j
II
'! $1,56000
03/31/2009 04 08 FAX 16195898113 AMERICAN A/C
AMERICAN ASPHALT AND CONCRETE, INC.
9011 MEMORY LANE
SPRING VALLEY, CA 91977-2152
Ph (619)589-8112 * Fax (619)589-8113
CA License No 688323
PROPOSAL / CONTRACT
NAME/ADDRESS
ATOMIC iNVCSTMEN-iS, INC
3200 B4-2 HIGHLAND AVtMUE
NATIONAL CITY CA 91950
TERMS
NET UPON COMPLETION
REP
or
AMERICAN
Asphalt & Concrete, inc.
DATE
3/26/2009
ESTIMATE
No
8708
PROJECT
2045 COR f£ DE NOGAL
PHONE NUMBERS
OFF/619-23^-7966
FAX/619-263-2995
DESCRIPTION TOTAL
1 BLACK OUT EXISTING UXiO
2 POWER CLEAN AND APPLY ONE COAT OF FMULSION StAL TO
ASPHALT TOTALING APPR.OX 4500 S F
3 STRIVE AS PCR PLAN
(ITEMS 1 3 ONLY)
4 INSTALL (2) HANDICAP SIGNS WITH POSTS
(ITEM 4 ONLY)
1,26000
30000
I'HANK YOU FOR THIS OPPORTUNITY TO BID YOUR PROJECT TOTAL $1,560 oo
D TO BE MEASURED ON COMPLETION AND INVOICED AT UNIT PRICES
D Mot responsible for reflective cracking thru overlays & skin patching
D Not responsible for weed growth from adjacent property
D Crack filling does not imply crack repair
D Not responsible for pre-existing subgrade
AMERICAN ASPHALT AND CONCRETE, INC.
Q Not responsible for pre-existing engineering with respect to drainage
D Not responsible for beck-fill and compaction or back nil installed by others
D Engineering testing, inspection and permit fees not included
Q Not responsible for underground utilities in areas to be removed
By
CUSTOMER ACCEPTANCE CREQTYNER
I/We accept the within proposal and agree to pay the said amount In accordance with the terms set forth All of the terms and
definitions on the reverse aide are Incorporated herein and made a part hereof.
Company
Customer Signature
_Date
Customer
#_
White Contractor's Copy * Yellow Customer's Copy * Pink Office Copy * Blue Log Copy
RALPH TEVSSIER
162 NORTH SYCAMORE AVENLE
Los ANGELES, CALIFORNIA 90036
1 December 2008
Mr Will Foss, Chief Building Official
CITY OF CARLSBAD, Building Department
1635 Faraday Avenue
Carlsbad, CA 92008
Re Letter of Certification of Existing Mechanical Enclosure at
2045 Corte del Nogal, Carlsbad, CA
Dear Mr Foss
As requested by the City of Carlsbad, architectural and structural drawings have been prepared
and submitted to the Building Department for the existing mechanical enclosure located at the
above referenced address
I serve as the Structural Engineer of Record and have prepared calculations with the drawing
submittal package Further, as a requirement to waive special inspection of the enclosure's
CMU wall screen, I have performed a review of the subject walls I find that the enclosure walls,
in addition to all the other structural framing components, substantially meets the general
structural intent of the building code
Sincerely,
Ralph Teyssier, S E
CALic S3727
S3727
EXP 12/31/2009
cc Mr Mark Swenson, AIA, Architect, Studio C Architects