HomeMy WebLinkAbout2051 PALOMAR AIRPORT RD; A; CB980788; Permitv(O3 B U I L D I N G P ERM I T Permit No: CB980788 6/12/98.1136 , . Project No: A9801038 Page1 of .1 • . Development No: Job Address: 2051 PALOMAR..AIRPORT RD Suite: A PerrritType: COMMERCIAL TENANT IMPROVEMENT .. Parcel No: 213-050-39-00 .', Lot#: Valuation: 187824 Construction Type: VN * Occupancy Group: B/A-3 f Reference#: Status: I SSUED Description: CTI 4816 SF-CAFETERIA . Applied: 03/17/98 FROM OFFICE TO CAFETERIA : - Ajar/Issue: 06/12/98 Enteied By: JM Appl/Ownr : WHARTON LARRY 619 203-1773 . • 639 BISON COURT . . 801306/121% 0001.01 02 0 EL CAJON CA . 92019 . . . C-PRMT 1586.0 * Fees Required . ** ** Fee Colleted & Credits, -----Fee-----1,8350 (2 N Adjustments: ..00f'( 00 Total Fees:. 1,8 . . Total, S.. • 249.00 1,586.00 Fee description Ext fee -Data Building Permit.. Plan Check 604.00 Strong Motion.Fee Pleu Gas Piping. System I H Y. : Remodel/Alter per AMP . r4OOP9ATED 2 ( 50.00 1952 Enter 'Y' for èclanic \9e.F'e : . . 1.5.00y Install Furn/Ducts/Het WI/ Each Hood 6.50 26.00 OVAL * - - . • . .. ,. . •*• -,.._ . - • . . - . -. . INS DATE CLEARANCE . - .,•• .- CITY OF CARLSBAD . • 2075 Las Patinas Dr., Carlsbad, CA 92009 (619)438-1161 .1 - V FOR OFFICE USE ONLY 4t 06 PERMIT APPLICATION PLAN CHECK NO.. CITY OF CARLSBAD BUILDING DEPARTMENT ' EST.VAL. ?2075 Las PáI Dr., Carlsbad CA 9009' -- Plan Ck Deposit V61id~tid B* (760) 438-1161 1 ROL!OTI çi Address (include Bldg/Suite #) . Business Name (atthis address) ' 'AlF'iiv'P Legal Description Lot NoC' Subdivision Name/Number Unit Nb. 'Phase No. Total # of units Assessor's Parcel # . Existing Us e1 "' 'Description of Work - - 'SQ. FT. #of S ones # of Bedrooms '• C"PtIW of Bathroom'+" 00 v11.th 446 Name . -.- Address . / -' City Stat Zip Tlephono Fax # gr rQ orE Agent for Owner ---, Name 44#V tW/d4174f Address 54/ Ci S$Zi _,Telep)oq # %PROP1'jOWNER - Name Address , ' City State/Zip Telephone # (Sec. 7031.5 Business and Professions Code: Any City, or, County which requires a permit to construct, alter,.improve, demolish or repair any Structure, prior to its issuance,' also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License' Law IChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant fo a pa mit ubjects the applicant to a civil penalty of not mor than five hundred dollars l$50011. , r i4/ /' 1 44/i4 1' 34 V' 3S -07/ O Name (' )" iJ 1# C ,. Address ' City ' State/Zip Telephone # State License4 " License Class' City Business License ..................... :. Designer Name , Address . . . ',. " City 'State/Zi Telephone' State License # ' , . ' ..'' - -- -. - Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: - 0. I have and will maintain a certificate of Con sent'to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. . I have and will maintain-workers'compensation; as required by Section '3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company S Policy No._____________________________ Expiration Date ______ (THIS SECTION NEED NOT BE-COMPLETED IF THE PERMIT IS-FOR ONE HUNDRED DOLLARS ($1001 OR LESS) 04 CERTIFICATE OF EXEMPTION: I certify that,in the performance of the ,work for which this 'permit is issued, I shall not employ any. person in any rnanner'so as - to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful,' and shall' subject an employer to criminal penalties and civil fines up to brii hundred thousand dollars ($100,000), in addition to the cost of bornpensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE ' ". . ' ' . ' - DATE ' 07 773 - " I hereby affirm that I am exempt from the Contractor's License Law for the following reason: . .. i, aW'owrer of,the property or my employees with wages as their sole compensation, will do the work and the 'structure is not into or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Licercse Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is old within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the Property, am exclusively, contracting with licensed contractors to construct the project (Sec. 7044,-Business and Professions Code: Th 'Contractor's LicenseLaw does notapply to an 'Owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this 'reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO I (have / have not) signed an applicàtioh for a building per for the proposed work. have contracted. with the following person (firm) to provide the proposed construction (include name / address / phone number /'contractors license number): ' I plan' to provide portio'ns of ihe work,' but I have hired the following person to coordinate': supervise and provide the major work (include name / address / phone number / contractors license number): , ' . • ' ' " ..... I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name /,address / phone numbei/ type of work): PROPERTY OWNER SIGNATURE ' . ' ' DATE RESIDA1 Th'NGPERMffSOtV - , Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or. risk management and prevention program under Sections 25505, 25533' or 25534 of the Presley-Tanner Hazardous-Substance Account Act? 0 YES 0 N0 Is the applicant or future building occupant required to obtaina pet frdm the air pollution control istrict or air quality management district? .0 YES 0 NO Is the facility to be, constructed withih 1,000 feet of the outer boundary, of ,,a school site? 0 YES 0 'NO IF ANY OF THE ANSWERS ARE YES, 'A FINAL-CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS, MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. , C I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER'S NAME . , ' ' 'LENDER'S ADDRESS JIcANTCRIlJIcTloN _T_- - T' Icertify that I have read the applicatiOn and state that the above informationis correct and that the information on the plans, is accurate. 'agree to comply with all City r,ordiñances and 'State laws-relating to building'construction: I hereby authorize representatives of the Cit, of Carlsbad to enter upon the above mentioned property for inspection purposes. I 'ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS,'COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY'IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is requur'ed for excavations over 5 0 deep anddemolituon or construction of structures over 3 torues in.height EXPIRATION: Every permit'i'aued byth'e Building Official under the provisions of'this'Code shall expire bylimitation and become null 'and if the b6i1din'g'or work authorized bysuch, permit is not commenced within 3,65 days from the e uch ermitor if the building or' work authorized by such permii is suspended or. abandoned at any time after the work is commenced for a period of 18 y tio 6.4.4 UhifOrm Building Code). APLIC'ANT'S SIGNATURE __' _' - DATE' 'WHITE I e -' YELLOW: Applicant PINK: Fiane -- rx'o CITY. OF CARLSBAD INSPECTION REQUEST PERMIT# CB980788 FOR 11/23/98 DESCRIPTION: CTI 4816 SF-CAFETERIA FROM OFFICE TO CAFETERIA TYPE: CTI JOB ADDRESS: 2051 APPLICANT: WHARTON CONTRACTOR: OWNER: REMARKS: C/DALE/918-0971 SPECIAL INSTRUCT: PALOMAR AIRPORT RD LARRY PHONE: PHONE: INSPECTOR AREA TP PLANCK# CB980788 0CC GRP B/A-3 CONSTR. TYPE VN STE: A LOT: 619 203-1773 PHONE: INSPECTOR TOTAL TIME: --RELATED PERMITS-- CD LVL DESCRIPTION PERMIT# TYPE STATUS AS980049 ASTI ISSUED FS980037 FIXSYS ISSUED AS980081 ASTI ISSUED FAD98039 FADD ISSUED CB980894 MISC ISSUED ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP 100998 Final Combo NS TP 100898 Final Combo NR TP 100598 Final Combo CO TP 100198 Rough/Ducts/Dampers AP TP 100198 Rough Electric AP TP 100198 Frame/Steel/Bolting/Welding AP TP 092598 Rough/Ducts/Dampers CO TP 092598 Rough Electric CO TP 092598 Frame/Steel/Bolting/Welding CO TP 090298 Interior Lath/Drywall AP TP 090298 Frame/Steel/Bolting/Welding AP TP 082798 Interior Lath/Drywall AP DH 082798 Rough/Ducts/Dampers AP DH 081498 Interior Lath/Drywall AP DH 081298 Rough/Ducts/Dampers AP TP 081298 Rough Electric AP TP 081298 Rough/Topout AP TP 081298 Frame/Steel/Bolting/Welding AP TP 081298 Interior Lath/Drywall AP TP COMMENTS NOT READY QUES REQ T-24 ISSUES DUCTS CElL LITES T-BAR CElL DUCTS @ KIT CElL LITES @ KIT T-BAR CElL @ KIT INT GREASE SHAFT D.W. INT GREASE SHAFT FRM OK TO EXT DUCT W/COMP SHAFT GREASE DUCT GREASE SHAFT WALLS, SOFFIT FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE' PLANNING CMWD ST LITE PLAN CHECK#: CB980788 DATE: 10/05/98 PERNIT#: CB980788 PERMIT TYPE: CTI PROJECT NAME: CTI 4816 SF-CAFETERIA FROM OFFICE TO CAFETERIA ADDRESS: 2051 PALOMAR AIRPORT RD SUITE# A 11'n i 0 1998 CONTACT PERSON/PHONE#: C/918-0971 SEWER DIST: CA WATER DIST: CA INSPECTED BY: INSPECTED BY: INSPECTED BY: DATE INSPECTED: (I1 DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS: EsGil Corporation In. Partnership with Government for Building Safety DATE: 6/11/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-788 SET: IV CJURI CANT EVIEWER O FILE PROJECT ADDRESS: 2051 Palomar Airport Rd. Ste A PROJECT NAME: Pinnfund Employee's Cafeteria TI El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. IN The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in Remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LII The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Don Pittman In person plan recheck Date contacted: (by:: ) Fax #: Mail Telephone Fax In Person • REMARKS: Don Pittman will carry the perforated Owner and City Set IV to the City of Carlsbad Building Department today. He will deliver the completed and signed special inspection program for the field welding and a third identical plan set to the Building Department at another time per telephone approval from Mike Peterson. He was advised A permit may not be issued at this time. By: Mike Puckett Enclosures: Esgil Corporation LI GA LI CM [:J EJ LI PC log trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax(619)560-1576 EsGil Corporation In Partnership with government for Building Safety DATE: 6/5/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-788 O APPLICANT JURIS. O PLAN REVIEWER 0 FILE SET: III PROJECT ADDRESS: 2051 Palomar Airport Rd. Ste A PROJECT NAME: Pinnfund Employee's Cafeteria TI II The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. U The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. U The applicant's copy of the check list has been sent to: Larry Wharton Fax to: Donald Pittman 619-273-4141 639 Bison Ct. El Cajon, Ca. 92019 Lisa Snyder 760-918-0973 U Esgil Corporation staff did not advise the applicant, except by mail and Fax, that the plan check has been completed. - Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LI REMARKS: By: Mike Puckett Enclosures: Esgil Corporation E GA EJ CM El EJ El Pc 5/27/98 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576 Carlsbad 98-788 6/5/98 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO: 98-788 OCCUPANCY: A-3 TYPE OF CONSTRUCTION:.VN ALLOWABLE FLOOR AREA: SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 6/5/98 JURISDICTION: Carlsbad USE: Cafeteria/ Kitchen ACTUAL AREA: 4,816sf TI STORIES: HEIGHT: OCCUPANT LOAD: 182 Revised DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/27/98 PLAN REVIEWER: Mike Puckett FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1994 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation .of any state, county or city law, To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot Carlsbad 98-788 6/5/98 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438- 1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The following are items not completely addressed from the previous plan review and corrections generated by the new information shown on the plans. 3. Item # 5 At detail E/3.1 show maximum height for proposed 25ga. 2 1/2" studs at 24"o.c.(1l'-1") from ICBO report #2274 and show size spacing and gage of studs to be used that exceed those for the 2 1/2" studs. The height shown on the detail of 13'-0" still exceeds the size and spacing of the studes per the manufacturer listing. Note, the suspended ceiling does not offer any lateral bracing unless specifically designed for that purpose. 4. Item # 6 When additional doors are provided for egress purposes, they shall conform to the width, swing and hardware provisions in Chapter 10. Sections 1004.3 and 1004.6. See Sec. 1004.12.Show an open passageway from the walled patio to the adjacent yard for exiting or if a gate is installed at the passageway show panic hardware at the gate leading to the adjacent yard. It is necessary to show the path of egress to the public way or yard on the plans. 5. Item # 11 Provide mechanical ventilation in all rooms capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1 Show amount of outside air provided for the occupant load of the area on the M-1 sheet. Please use the occupant load determined by Table IOA UBC. 6. Item # 12 Show the vent for the pizza oven to extend separately to the outside from beneath the hood above or show the manufacturer's listed interlocking device required between the hood and the pizza oven per Section 818.2 UMC. No Response. 7. Item # 16 Provide construction details of required fire rated grease duct enclosure and hood enclosure. UMC, Sections 507.6, and 508.4.1 Please detail the rated shaft assembly. No Resonse. Carlsbad 98-788 6/5/98 Item # 18 The fire-rated grease duct and/or hood enclosures must extend from the point of penetration of the ceiling up to the roofing. The ceiling or hood enclosure must be over the hood. UMC, Sections 5076, 508.4, and 508.4.1 Please detail on the plans. No response. Item # 21 Show required cleanouts for grease duct on hood. UMC, Section 507.5 Show the required protected openihg at the shaft penetration to access the cleanout. Please show the cleanouts at the horizontal type I hood ducting at the east kitchen area. Item # 28 Show the grease trap on the plumbing isometric to serve all grease producing plumbing fixtures. It may be necessary to add grease traps to accommodate all the fixtures served by the grease traps. All pot sinks, mop sink and floor drains must be served by a grease trap. Show the associated flow control and vent for the flow control in conjunction with the size and type of grease trap provided and note that the flow control must be readily accessible at all times. Please provide the necessary sizing calculations per Appendix H for the proposed grease interceptor. Please remove the grease trap detail from the plans. Item # 29 Please detail the duct enclosure shaft and show on the floor plan of the 2nd floor and roof where the penetrations will occur. No response. Item # 30 Provide calculations for the design of the penetrations through the structural floor and roof by the Engineer. No Response. Item # 31 Complete the Special Inspection Program document attached and return with the plan review corrections for recheck. No Response. To speed up the review process; note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list?. Please indicate: Yes LJ No L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Puckett at Esgil Corporation. Thank you. A. 51FCIAL IN5PEGTION PROGRAM APpRS$ OR LEGAL DE8CRiPTlON 22S( Jii/1 2 50i7 '/'QO PLAN CKCK NUMBER: OWNERS NAME: 50A)j Load- . I, as the owner, or agent of the owner (contractors may W epioy the speCial inspector), oertlfy that I, or the aroNteaVengineer of record,will be responsible for employing the special Inspectors) as required by Uniform Building Code (U3C) Section 17D1.1 for the construction project located at the site liste sbov5. UC5ecton 105.35 Slaned I is the engineer/arohltact of record, certify that I have prepared the foHowng special inspection program as required Oy U8C Section 106.3.5 for Me construction project located at the site listed above, - ---.--- - - - Dn,lamArS I a iiups ?qss 81;nid -. 1, List of work requiring epsolal Inspection: Soils Compliance Prior to Foundation inspection R R StrMatural Concrete Over 200 PSI Preetrunad Concrete $tructurl Masonry Deslri.r SpecIfied Field Welding HIP1 Strength Bolting El pirI5t*nlpOXy Anchors SpfaysdOn Fireproofing Other -- 2 Name(s) of Individual (a) or firm(s) responsible for the speCial lneaetions listed above i JeL 7 3, Dulges of the speotal Inspactors for the work Hid above: ----u-I---- - -&__ --- - -" 86. 9t-0-6t9:XP. NOtidOdQ 11S EsGiI Corporation In Partnership with government for Building Safety DATE: 5/12/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-788 SET: II D APPLICANT JURIS. Ua-EAN REVIEWER ILE PROJECT ADDRESS: 2051 Palomar Airport Rd. Ste A PROJECT NAME: Pinnfund Employee's Cafeteria TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Larry Wharton Fax to: Donald Pitman 619-273-4141 639 Bison Ct. El Cajon, Ca. 92019 Lisa Snyder 619-350-3748 Esgil Corporation staff did not advise the applicant, except by Fax, that the plan check has been completed. - LI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LI REMARKS: By: Mike Puckett Enclosures: Esgil Corporation 0 GA fl CM J EJ D PC 4/30/98 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax(619)560-1576 Carlsbad 98-788. 5/12/98 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 98-788 OCCUPANCY: A-3 ITYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 5/12/98 JURISDICTION: Carlsbad USE: Cafeteria / Kitchen ACTUAL AREA: 4,816sf TI STORIES: 1 HEIGHT: OCCUPANT LOAD: 201 DATE PLANS RECEIVED BY. ESGIL CORPORATION: 4/30/98 PLAN REVIEWER: Mike Puckett FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the1994 UBC. The following items listed needtclarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot Carlsbad 98-788 5/12/98 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bringone corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. The following are items not completely addressed from the previous plan review and corrections generated by the new information shown on the plans. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code as per the previous plan review corrections. Not all the sheets are signed. Please obtain Health Department Approval. No response. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Note, a licensed Architect may be required to stamp seal and sign the plans if exiting is complex or structural changes will be made as a result of code requirements. Please have a licensed Architect or Engineer stamp seal and sign all sheets of the plans except the Mechanical, Kitchen, Plumbing, and Electrical which may be signed by the design and build Contractor or a licensed Engineer within the discipline designed. On the first sheet of the plans indicate: The floor area of the existing building. The floor area of the remodeled area, All occupancy groups within the building. The occupant load of the remodel area(s). The floor where the tenant improvement is located, Please present this project data information on the Title Sheet as described. Note, the occupant load factor for the serving area is 1:15. 5. At detail E/3.1 show maximum height for proposed 25ga. 2 1/2" studs at 24"o.c.(ll'-l") from ICBO report #2274 and show size spacing and gage of studs to be used that exceed those for the 2 1/2" studs. There is no change in this detail to reflect the correction the maximum height still exceeds the size, spacing, and gage of the studs shown. Carlsbad 98-788 5/12/98 When additional doors are provided for egress purposes, they shall conform to the width, swing and hardware provisions in Chapter 10. Sections 1004.3 and 1004.6. See Sec. 1004.12. Show doors leading into cafeteria from the interior of the building to be panic hardware equipped. Show an open passageway from the walled patio to the adjacent yard for exiting or if a gate is installed at the passageway show panic hardware at the gate leading to the adjacent yard. ELECTRICAL Please note on the plans that the electrical conduits will be sealed on the inside as per NEC Art. 300-7 at the penetration of the freezer box. Per the City of Carlsbad request please make a note that "No AC cable or Romex wiring methods are allowed". Show exit signs on the electrical lighting plan(s). Asper Sections 1012 and 1013 of the 1994 UBC, provide two sources of power to exit signs and exit illumination. MECHANICAL Show the size, location and type of all heating and cooling appliances or systems. Please provide the cfm of the units and show smoke detectors in the main air supply if they are in excess of 2,000cfm. Please identify the smoke detectors in a legend on the M-1 sheet. Provide mechanical ventilation in all rooms capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1 Show amount of outside air provided for the occupant load of the area on the M-1 sheet. Show the vent for the pizza oven to extend separately to the outside from beneath the hood above or show the manufacturer's listed interlocking device required between the hood and the pizza oven per Section 818.2 UMC. Please provide the listing information and installation instructions for the proposed Type 1 Hoods. Please show the materials and gage of the exhaust and make up air ducts. Please provide the calculations for the sizing of the ducts on M-1 for the values given on sheet K-5 for the exhaust velocities as required in Section 507.8 UMC. Show the size of all the existing ducts on the plans, materials and gage of materials. Provide construction details of required fire rated grease duct enclosure and hood enclosure. UMC, Sections 507.6, and 508.4.1 Please detail the rated shaft assembly. Detail grease duct discharge clearances as per UMC, Section 507.11, (Minimum of 10 feet from parapet wall and air intake of HVAC unit.) Carlsbad 98-788 5/12/98 The fire-rated grease duct and/or hood enclosures must extend from the point of penetration of the ceiling up to the roofing. The ceiling or hood enclosure must be over the hood. UMC, Sections 507.6, 508.4, and 508.4.1 Detail grease duct discharge clearances as per UMC, Section 507.11, (Minimum of 10 feet from parapet wall and air intake of HVAC unit.) The fire-rated grease duct enclosures must be sealed around the duct at the point of penetration of the ceiling. UMC, Section 507.6 Show required cleanouts for grease duct on hood. UMC, Section 507.5 Show the required protected opening at the shaft penetration to access the cleanout. Detail 1/4 inch per foot slope on grease duct back to hood. UMC, Section 507.4 Each room provided with a kitchen exhaust system shall have air supplied to the room equal to the amount of air to be exhausted. Please show that the two systems equal one another on the M sheet. The exhaust and make-up air systems shall be connected by an electrical interlocking switch. UMC, Section 402.4 PLUMBING Detail the condensate drain routing and termination for the walk in freezer/cooler. Please show the location of the water heater. Are there other demands on the existing 1 1/4" water supply? If so, show those on the calculations for the pipe sizing. Show the location of the RPP backflow preventer at the water supply to the carbonator. Show on the water isometric that the carbonator protects only water serving the carbonator and that it supplies no other appliances. Show the routing of the drain for the RPP device to an approved receptor. Show the grease trap on the plumbing isometric to serve all grease producing plumbing fixtures. It may be necessary to add grease traps to accommodate all the fixtures served by the grease traps. All pot sinks, mop sink and floor drains must be served by a grease trap. Show the associated flow control and vent for the flow control in conjunction with the size and type of grease trap provided and note that the flow control must be readily accessible at all times. STRUCTURAL Please detail the duct enclosure shaft and show on the floor plan of the 2nd floor and roof where the penetrations will occur. Provide calculations for the design of the penetrations through the structural floor and roof by the Engineer. Carlsbad 98-788 5/12/98 Complete the Special Inspection Program document attached and return with the plan review corrections for recheck. DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL TITLE 24 DISABLED ACCESS REQUIREMENTS Please show on the plans that checkstands shall provide: . A 36" aisle on the customer side of the checkstand. Accessible checkstands shall provide a clear check-out aisle width of 36" with an adjoining counter :Q8" above finished floor. Note that they will always be open and be identified by a sign clearly visible to those in wheelchairs. 33'. On the site plan show the accessible path of travel from the complying disabled accessible parking space(s) to the entrance of the building. 34. Please show that the existing restrooms are disable accessible complying. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. - Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Puckett at Esgil Corporation. Thank you. EsGil Corporation In Partnership with Government-for Building Safety DATE: 3/30/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-788 SET:I O ANT JURIS. C3 PLAN REVIEWER U FILE PROJECT ADDRESS: 2051 Palomar Airport R. Ste. A PROJECT NAME: Pinnfund Employee's Cafeteria TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. E The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. S The applicant's copy of the check list has been sent to: Larry Wharton 639 Bison Ct. El Cajon, Ca. 92019 S Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has been completed. El Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: : Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LI REMARKS: By: Mike Puckett . Enclosures: Esgil Corporation El GA El CM [-1 EJ 171 PC 3/19/98 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576 Carlsbad 98-788 3/30/98 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 98-788 JURISDICTION: Carlsbad OCCUPANCY: A-3 USE: Cafeteria/ Kitchen TYPE OF CONSTRUCTION: VN ACTUAL AREA: 4816sf TI ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 2/17/98 DATE INITIAL PLAN REVIEW COMPLETED: 3/30/98 OCCUPANT LOAD: 201 DATE PLANS RECEIVED BY ESGILCORPORATION: 3/19/98 PLAN REVIEWER: Mike Puckett FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments-may be required prior to the issuance of a building permit. Cdde sections cited are based on the 1994 UBC. The following items Jisted need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot Carlsbad 98-788, 3/30/98 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Please obtain Health Department approval. 3. Each sheet of the plans must be signed by the person responsible for their. preparation, even though there are no structural changes. Business and Professions Code. Note, a licensed Architect may be required to stamp seal and sign the plans if exiting is complex or structural changes will be made as a result of code requirements. 4. Provide a statement on the Title Sheet of the plans-that this project shall comply with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC. 5. Show on sheet 0.2 of the plans where within the building the tenant improvement is located. 6. The proposed tenant improvement is a change of occupancy from the existing use; a B to an A-3 occupancy. The area of the tenant improvement is that for the A-3 and accessory kitchen and storage area use. On the first sheet of the plans indicate: . The floor area of the existing building. The floor area of the remodeled area, All occupancy groups within the building. The occupant load of the remodel area(s). The floor where the tenant improvement is located, 7. Please show that the area of the A-3 is allowed per Section 504.3 UBC for a mixed occupancy. Please show the computation. 8. Please show use of adjacent existing rooms to the tenant improvement. r Carlsbad -98-788 3/30/98 Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 106.3.3. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. At detail E/3.1 show maximum height for proposed 25ga. 2 1/2' studs at 24"o.c.(1l'-1") from ICBO report #2274 and show size spacing and gage of studs to be used that exceed those for the 2 1/2" studs. Note on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-0 and 16-B. In areas where the occupant load exceeds 49 two exits are required. See Item #4 Table 10-A. Provide an exit analysis plan. Show the exit path of travel for both required exits. Show all fire rated corridors if applicable that lead to the public way, or yard. Exit doors from Group A, E, H-I, H-2, H-3 and I occupancies shall not be provided with a latch or lock unless it is panic hardware. Chapter 10. Please note on the plans the type of hardware required. When additional doors are provided for egress purposes, they shall conform to. the width, swing and hardware provisions in Chapter 10. Sections 1004.3 and 1004.6. See Sec. 1004.12. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1013.1. If fire rated corridors are to be created for exiting please provide a complete architectural section of the corridor, or exterior exit balcony, showing all' fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 1005.7. Show on the plans that the freezer box complies with Section 2602.4 UBC Carlsbad 98-788 3/30/98 ELECTRICAL S Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations. Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. S Please note on the plans that the electrical conduits will be sealed on the inside as per NEC Art. 300-7 at the penetration Of the freezer box. Per the City of Carlsbad request please make a note that "No AC cable or' . S Romex wiring methods are allowed". Show exit signs on the electrical lighting plan(s).. As per Sections 1012 and 1013 of the 1994 UBC, provide two sources of power to exit signs and exit illumination. Provide multiple switch lighting controls per Title 24, Part 6. MECHANICAL Show the size, location and type of all heating and cooling appliances or systems. Please provide the cfm of the units and show smoke detectors in the main air supply if they are in excess of 2,000cfm. 31. Provide mechanical ventilation in all rooms capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1 32. Show the point of disposal for the condensate drain at the freezer box. 33. Show the location of the compressor for the fan coils at the freezer box. 34. Please show all Kitchen appliances and identify each on the plans. Carlsbad 98-788 3/30/98 35. Provide complete kitchen hood plans, details, and calculations to show compliance with UMC, Chapter5, Part 11 as per the following: Provide the UL listing card showing the exhaust sizing requirements used for this hood. Provide roof framing around new openings in the roof for the exhaust and make- up air ducts for kitchen hoods. Provide exhaust sizing calculations for kitchen hoods. UMC, Section 508.7 Provide grease duct air velocity calculations. Minimum 1,500 fpm and maximum 2,500 fpm. UMC, Section 507.8 Provide construction details of required fire rated grease duct enclosure and hood enclosure. UMC, Sections 507.6, and 508.4.1 Detail grease duct discharge clearances as per UMC, Section 507.11, (Minimum of 10 feet from parapet wall and air intake of HVAC unit.) The fire-rated grease duct and/or hood enclosures must extend from the point of penetration of the ceiling up to the roofing. The ceiling or hood enclosure must be over the hood. UMC, Sections 507.6, 508.4, and 508.4.1 The fire-rated grease duct enclosures must be sealed around the duct at the point of penetration of the ceiling. UMC, Section 507.6 Show required cleanouts for grease duct on hood. UMC, Section 507.5 Detail 1/4 inch per foot slope on grease duct back to hood. UMC, Section 507.4 Each room provided with a kitchen exhaust system shall have air supplied to the room equal to the amount of air to be exhausted. The exhaust and make-up air systems shall be connected by an electrical interlocking switch. UMC, Section 402.4 Clearly show the material used to construct the hood and exhaust duct. UMC, Sections 508.2 & 507.3 An exhaust outlet within the hood shall be so located as to optimize the capture of particulate mater. Each outlet shall serve not more than 12 foot section of hood. UMC, Section 508.9. A complete kitchen hood system plan review will be done when complete hood system plans, details, and calculations are provided. L p Carlsbad 98-788 3/30/98 PLUMBING 36. Provide complete plumbing plans, including: Complete drain, waste and vent plans. Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1217.0 Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 Show water heater size, type and location on plans. UPC, Section 501.0 ENERGY Provide plans, calculations and worksheets to show compliance with current energy standards. The calculations submitted were for the wrong job and they were returned to the city. Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems. Provide the completed LTG- forms showing energy compliance. The completed and signed LTG-1 forms must be imprinted on the plans. DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL TITLE 24 DISABLED ACCESS REQUIREMENTS The following disabled access items are taken from the 1995 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities as follows: (1) Any building, structure, facility, complex, or improved area, or portions thereof, which are used by the general public. (2) Any sanitary facilities which are made available for the public, clients, or employees in such accommodations or. facilities. Any curb or sidewalk intended for public use that is constructed with private funds. S All existing accommodations when alterations, structural repairs or additions are made to such accommodations. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. Carlsbad 98-788 3/30/98 REMODELS, ADDITIONS AND REPAIRS When alterations, structural repairs or modifications or additions are made to an existing building, that building,, or portion of the building affected is required to comply with all of the requirements for new buildings, per Section 113413.2. These requirements apply only to the area of specific alteration, repair or addition and shall include: A primary entrance to the building and the primary path of travel to the area in question, and include the following items which serve the area in question: Sanitary facilities. Drinking fountains Public telephones. If an unreasonable hardship finding is granted, priority should be given to those elements that will provide the greatest access, per Section 113413.2.1 Exception #1. The order of priority shown below should be followed: . An accessible entrance. An accessible route of travel. At least one accessible restroom for each sex. Accessible telephones. Accessible drinking fountains. . When possible, additional accessible elements such as parking, storage and alarms. On the site plan show the accessible path of travel from the complying disabled accessible parking space(s) to the entrance of the building. Please show that the existing restrooms are disable accessible complying. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Carlsbad 98-788 3/30/98 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes E3 No The jurisdiction has contracted with Esgil Corporation located at 9320 - Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Puckett at Esgil Corporation. Thank you. Carlsbad 98-788 3/30/98 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 98-788 PREPARED BY: Mike Puckett . DATE: 3/30/98 BUILDING ADDRESS: 2051 Palomar Airport R. Ste. A BUILDING OCCUPANCY: B/A-3 TYPE OF CONSTRUCTION: VN BUILDING PORTION BUILDING AREA (ft.2) VALUATION MULTIPLIER VALUE ($) Cafeteria TI 4,816 39.00 187,824.00 Air Conditioning Fire Sprinklers TOTAL VALUE 187,824.00 1991 UBC Building Permit Fee El Bldg. Permit Fee by ordinance: $ 947.50 01991 UBC Plan Check Fee El Plan Check Fee by ordinance: $ 615.87 Type of Review: El Complete Review El Structural Only El Hourly El Repetitive Fee ApplIcable El Other: Esgil Plan Review Fee: . $ 492.70 Comments: Sheet I of I macvalue.doc 5196 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ' DATE ADDRESS ;~757 ~ /V RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ___________ _______________ ENGINEER DATE DoJMIsformsiPIanrnng Engineering Approvals 11, City of Carlsbad 98016.1 Fire Department Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report:Thursday, May 14, 1998 Reviewed by: i e.) L~jc, Contact Name LarryWharton Address 639 Bison Ct City, State ElCajonCA92019 Bldg. Dept. No. CB980788 Planning No. Job Name Pinnfund Job Address 2051Palomar Airport Ste. or Bldg. No. A jpprove.- The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. E Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFD Job#98016-1 File#__________ 2560 Orion Way 0 Carlsbad, California 92008 0 (619) 931-2121 JUN-10-98 WED 10:40 P02 Firouzi Consulting Engineers, Inc. a structural analysis and design company STRUCTURAL CALCULATIONS' PROJECT NAME: DATE: ENGINEER OF RECORD ..•••• ••• :• S S S S. • P I1'NFIJIN]D S S • S •• • ••SSS. • S... JUNE 4, 1998 :.. :...: • S..... FIROUZI CONSULTING : .. ENGINEERS, INC. S ':'. rIj S•S•• • S JN—$0-98 WED 10:41 flROUZI CONSULTING ENGINEERS, INC. 16959 Bernardo Center Drive, Suite 201 San Diego, California 92125 Phone (619) 485-6227, Fax (619) 48.6201 P 03 Project: Pinnfund Job #: By: Date: June '98 Page 1 DESIGN LOADS Roof Members 'p Floor Members Dead Load Roofing 6.0 psf Framing 3.5 Plywood 1.5 Insulation 0.5 Ceiling 2.0 Misc 1.5 TOTAL 15.0 psf Dead Load Roofing 6.0 ..S .is1. Framing 1.5 Plywood 1.5 Insulation 0.5 Misc 1.5 TOTAL 11.0 : 'S.. .. . S • Live Load 0 - 200 sq. ft 20 S. S psf 201-600 sq. ft 16 psf Over 600 sq. ft. 12 psf Office Dead Load 25 psf Partition Load 20 psf Live Load 80 psf Concentrated Load per usage Roof Beams & Purlins Roof Sub-purlins Firouzi Consulting Engineers, Inc. Title: PinnIuiid Job # .46951 Bernardo Center Dr., Ste. 216 Dsgnr: Date: San Diego, California 92128 Description: 1=1.00 -A- 400r. Obeculacrs Scope : Building Improvements Steel Beam Design '. LGeneral Description New Beams Steel Section W8X1O Fy 36.00ks1 Pinned-Pinned Load Duration Factor 1.00 Center Span 10.00 ft Bm Wt. Added to Loads Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu 0.00 ft [Distributed iLoads #1 #2 #3 #4 #5 #6 #7 DL 0.203 k/ft LL 0.360 . k/ft ST k/ft Start Location . ft End Location ft wmmary . Beam OK Using: W8X10 section, Span = 10.00ft, Fy = 36.0ksiEnd Fixity = Pinned-PinnedFy = 38.00ksi, Lu = 0.00It, LDF = 1.000 .....: Actual Allowable Moment 7.163 k-ft 15.459 k-ft Max. Deflection • -0.44 In fb : Bending Stress 11.010 ksi 23.760 ksi Length/DL Defi Y.hlf :1 fb I Eb 0.463: 1 Length/(DL+LL Defi) • 834.3 : 1 .SS.• • S... S S S S • . S S . S Shear fv: Shear Stress fv/Fv Force & Stress Summary 2.865 k 19.315 k 2.136 ksi 14.400 ksi 0A48 : 1 S S S. • <<-- These columns are Dead + Live Load placed as noted .->> DL LL LL+ST LL LL+ST Only P Center Center (1 Cants (@ Cants 2.66 7.16 k-ft k-ft k-ft k-ft 1.07 2.87 k 1.07 2.87 k Max. M + Max. M - Max. M @ Left Max. M @ Right Shear © Left Shear @ Right Maximum 7.16 k-ft 2.87k 2.87k / •5 S S • S... ii .1 Center Deft. -0.144in -0.054 -0.144 -0.144 0.000 0.000 in Left Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in Right Cant Def .0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Deft @ 0.000 in 0.000 0.000 0,000 0.000 0.000 in Reaction © Left 2.87 1.07 2.87 2.87 k Reaction © Rt 2.87 1.07 2.87 2.87 k Lsection Properties Steel Section W8XIO Weight 10.05 #/ft r-xx 3.226 in Depth 7.89 in lxx 30.80 in4 t-yy 0.840 in Web Thick 0.170 in lyy 2.09 in4 Misc 0.990 in Width .3940 in Sxx 7.807 in3 Flange Thick 0.205 in Syy 1.061 in3 Area . 2.96 1n2 (C) 1983-97 ENERCALC -. c:\enercalc\pinnIund.ecw KW-0602755, V5.0.2, 1-Jun-1997