Loading...
HomeMy WebLinkAbout2051 Palomar Airport Rd; 110; CBC2018-0277; Permit{'city of Carlsbad Commercial Permit Print Date: 11/29/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2051 Palomar Airport Rd, 110 BLOG-Commercial 2130503900 $511,610.00 Work Class: Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Description: IDEX HEALTH & SCIENCE: 11,000 SF T.I. OFFICE TO OFFICE Owner: Tenant Improvement PALOMAR ACQUISITIONS PARTNERS LLC BUILDING PERMIT FEE ($2000+) BUI LOI NG PlAN CHECK FEE (BLDG) 4747 Executive Dr, Ste 410 San Diego, CA 92121-3091 858-435-4000 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL GREEN BUILDING STANOARDS PlAN CHECK & INSPECTION MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMOOEL PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $4,328.35 Total Payments To Date: $4,328.35 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBC2018-0277 Closed -Finaled 05/22/2018 09/05/2018 PBurn 11/29/2018 10:07:24AM $0.00 $2,073.00 $1,451.10 $242.00 $170.00 $104.00 $124.00 $21.00 $143.25 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov / / / / / THE FOLOOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: l2[PLANNING o;J!;NGINEERING DJilUILDING IEFIRE •HEALTH []i'l'HAZMATIAPCD · C_cityof Building Permit Application Plan Check No. CP ".,;io I 9 -0 2. 7 -, 1635 Faraday Ave., Ca~sbad, CA 92008 Est. Value < ~ ll,1Dl0.()( ' Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov . www.carlsbadca.gov Date ,c:;, I:). J.. II n JOB ADDRESS SUITEt/SPACEI/UNIT# • IAPN 213 2051 Palomar Airport Road 110 -050 -39 - CT/PROJECT# I LOT# I PHASE# I# OF UNITS I# BEDROOMS #BATHROOMS l""j;~;-~;~;H & SCIENCE I coNsr; lYPE I occ. ;ouP 0 DESCRIPTION OF WORK: Include Square Feet of Affitcted Area(s) NEW OFFICE/LAB SPACE WITHIN AN EXISTING BUILDING. NEW PARTITIONS , MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT. NEW ROOF TOP MECHANICAL UNITS. EXISTING ACCESIBL~ESTROOMS TO REMAIN . NO CHANGE IN USE EGRESS OR OCCUPANCY. II. oao s Q. -Ff. EXISTING USE I PROPOSED USB I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE IAIR CONDITIONING I FIRE SPRINKLERS B YES[), No!:!] YEs0NoO YES0NoO APPLICANT NAME ALEKSEY SHAFIRO PROPERTY OWNER NAME Pete Shearer Prlma,v Contact ADDRESS ADDRESS 6363 Greenwich Drive Suite 175 525 BSTREET CITY STATE ZIP CITY STATE ZIP San Diego CA 92122 SAN DIEGO CA 92101 PHONE IFAX PHONE IFAX 619.564.5126 602.412.8330 EMAIL EMAIL ASHAFIRO@WAREMALCOMB.COM Pete.Shearer@hines.com DESIGN PROFESSIONAL copTRACTOR • · · -;;,-i-_ ~ v 1 '-O i rJ '1 L' C,,.:.b\l"P - ADDRESS ADDRESS 505 Lomas Santa Fe Dr #200 CITY STATE ZIP CITY STATE ZIP Solana Beach CA 92075 PHONE IFAX PHONE IFAX 858.967.2387 EMAIL EMAIL ieff!@c2sd.com A 15TATE UC.# STATE LIC.# ICLASS I CITY BU'lJ.C() /)/,;, pf/ 996486 B (Sec: 7031.5 Business ~nd Profe~ions Code: Any City or ~un~which requires a permit to,C9nstruct alter, impro~e. ~emolish or re air an structure, _rior t9 its iss\Jance,Jls(re~\Jifes the applicant for such permit to file a signed statement tfiat he 1s hcensed pursuant to the prov1s1ons of the Contractors License Law (C~a'fter ;, commen£nl! with Section 7000 of D1v1s1on 3 of the Business and Professions Code} or [hat he is exem.11t therefrom, and the basis for the alleged exemption. Any violation of Section 703 .5 by any applicantfor a permit subjects the applicant to a civil penalty of not more than five hundred dollars ti500)). WORKERS' COMPENSATION Workers' Compensation Declaratlon: I hereby affirm under penalty of petjury one of the following declarations: D I have and will maintain a certillcate of consent to stlf-lnsure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ')c' I have and wlll maintain workers' compensation, as required by Section 3700 of the La r Code, for the performance of the work for which this permit is issued. My workers' compensation ·nsura carrier and policy o,mbe,are:lasura,oeCo. ~~ ~ t wesr IC.W p~;cyNo.1.NPL 'Sf2'{J]'/io6 Exp;,at;oeoate (, / S Z-ol Jl!,i§.section need not be completed if the permit is for one hundred dollars ($100) or lass. LJ Certificate of Exemption: I certify that Jn the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure lo secure workers' compensation coverage 11 unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, dama s provided for in Section 3706 of the Labor coda, interest and attorney's fen. ~ CONTRACTOR SIGNATURE _,._3!',-,.-.,._.._ I hereby affirm that I am exempt from Contractor's License Law for the following reason: • • • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors lo construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant lo the Contractor's License Law). I am exempt under Section ____ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Oves 0No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. 1 have contracted with the foilowing person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I p1an to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work Onclude name I address I phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons lo provide the work indicated (include name I address I phone/ type of work): ~ PROPERTY OWNER SIGNATURE •AGENT DATE • COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acn • Yes • No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management disbicl? • Yes • No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there 1s a construction lending agency for the performance of the work. this permit is issued (Sec 3097 {i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certify that I have read the applicatioo and state that the above Information Is correct and that the lnfonnatlon on the plans is accurate. I agree to comply with all City ordinances and State laws relating to bull ding construction. I hereby aulrorize represenlalive oflhe Cily of Carlsbad ID enter upon lhe abow mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH WW IN AINWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA AA OSHA pem,t Is required for excavations °"'' 5'0' deep and demolnion or cons1JUction of slrucllles over 3 slories In heighL EXPIRATION: Every pem,lt issued by the BuHclng Official under provisions of this shall expire by limitation and become null and void if the building or WOJk authorized by such pem,it is not commenced 'Mthin 180 days from the date of such permit orif lhe building or~it'Jlho~ by su mil: is suspended or abandoned at anytirre after the work is oommenced for a period of 180 days (Section 106.4.4 Uniform BuMding Code). ~ APPLICANT'S SIGNATURE DATE &.J""-Z1-/, PERMIT INSPECTION HISTORY REPORT (CBC2018-0277) Permit Type: BLDG-Commercial Application Date: 05/22/2018 Owner: PALOMAR ACQUISITIONS PARTNERS LLC Work Class: Tenant Improvement Issue Date: 09/05/2018 Subdivision: PARCEL MAP NO 09959 Status: Closed -Finaled Expiration Date: 05/27/2019 Address: 2051 Palomar Airport Rd, 110 Carlsbad, CA 92011-1462 IVR Number: 11505 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re Inspection Complete 11/16/2018 11/16/2018 BLDG-91 076187-2018 Failed Paul Burnette Reinapection Complete Complaints Inspection Checklist Item COMMENTS Passed BLOG-Building Deficiency No 11/16/2018 11/16/2018 BLDG--34 Rough 076315-2018 Cancelled System Administrator Reinspection Complete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/2812018 11(2812018 BLDG-84 Rough 077076-2018 Partial Pass Andy Krogh Relnspectlon Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding {Decks) BLDG-24 Rough-Topout Yes BLOG-34 Rough Electrical No BLDG-44 Yes Rough-Ducts-Dampers BLDG-Flnal 077344-2018 Failed Andy Krogh Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Ok to occupy Yes BLOG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Two circuits show bad ground paths No 11/29/2018 11129/2018 BLDG-Final 077461-2018 Paseed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLOG-Building Deficiency Ok to occupy Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes November 29, 2018 Page 3 of 3 PERMIT INSPECTION HISTORY REPORT (CBC2018-0277) Permit Type: BLOG-Commercial Application Date: 05/22/2018 Owner: PALOMAR ACQUISITIONS PARTNERS LLC Work Class: Tenant Improvement Issue Date: 09/05/2018 Subdivision: PARCEL MAP NO 09959 Status: Closed -Finaled Expiration Date: 05/27/2019 Address: 2051 Palomar Airport Rd, 110 Carlsbad, CA 92011-1462 IVR Number: 11505 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re Inspection Complete 10111/2018 10/11/2018 BLDG-23 072538-2018 Partial Pass Mlchael Collins Reinapectlon Incomplete GasfTeatJRepalrs Checklist Item COMMENTS Passed BLDG-Building Deficiency Start 24 hr clock, 9:55 AM Yes 10/12/2018 10/12/2018 BLDG-23 072853-2018 Passed Michael Collins Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Completion of 24 hour gas test. Yes BLDG-Building Deficiency Start 24 hr clock, 9:55 AM Yes BLDG-86 T-Bar, 072862·2018 Partial Pass Michael Collins Reinspectlon Incomplete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-14 Hard lid soffit at Rm 105, pending Fire Yes Frame-Steel-Bolting-Welding Dept. approval (Decks) BLDG-34 Rough Electrical Yes 10/16/2018 10/16/2018 BLDG-17 Interior 072977-2018 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 10/2612018 10(26/2018 BLOG-86 T•Bar, 074315-2018 Partial Pasa Andy Krogh Reinspection Incomplete Celling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency As noted on card and mini set of plans in Yes green highlighted BLDG-14 Hard lid soffit at Rm 105, pending Fire Yes Frame-Steel-Bolting-Welding Dept. approval {Decks) BLDG-34 Rough Electrical Yes 11/06/2018 11/06/2018 BLDG-86 T-Bar, 076281-2018 Passed Paul Burnette Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency As noted on card and mini set of plans in Yes green highlighted BLDG-14 Hard lid soffit at Rm 105, pending Fire Yes Frame-Steel-Bolting-Welding Dept. approval (Decks) BLDG-34 Rough Electrical Yes November 29, 2018 Page2of3 PERMIT INSPECTION HISTORY REPORT (CBC2018-0277) Permit Type: BLOG-Commercial Application Date: 05/22/201 B Owner: PALOMAR ACQUISITIONS PARTNERS LLC Work Class: Tenant Improvement Issue Date: 09/05/2018 Subdivision: PARCEL MAP NO 09959 Status: Closed -Finaled Expiration Date: 05/27/2019 Address: 2051 Palomar Airport Rd, 11 O Carlsbad, CA 92011-1462 IVR Number: 11505 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 09/07/2018 09/07/2018 BLDG-21 069381-2018 PaHed Paul Burnette Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLOG-Building Deficiency No 09/10/2018 09110/2018 BLDG-84 Rough 069600-2018 Partial Pass Paul Burnette Reinspectlon Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLOG-44 No Rough-Ducts-Dampers 09/17/2018 09/17/2018 BLDG-34 Rough 070180-2018 Failed Paul Burnette Relnspection Complete Electrical Checklist Item COMMENTS Passed BLOG-Building Deficiency No 09126/2018 09/26/2018 BLDG-84 Rough 071036-2018 Passed Paul Burnette Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-VVelding (Decks) BLDG-24 Rough-Topout No BLOG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 10/0412018 10/0412018 BLDG-86 T-Bar, 072012-2018 Failed Paul Burnette Reinspection Complete Ceiling Grlda, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLOG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLOG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers November 29, 2018 Page 1 of3 DATE: Aug.30,2018 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2018-0277 ✓• EsG1I A SAFEbuilf Company SET: III PROJECT ADDRESS: 2051 PALOMAR AIRPORT ROAD PROJECT NAME: T.I. FOR IDEX HEALTH & SCEINCE • APPLICANT • JURIS. 1:8] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: 1:8] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Aleksey Shafiro c/o WM AIA Telephone#: 619-564-5126 Date contacted: /~/ (b¼{.i ) Email: ashafiro@waremalcomb.com Mail Telephone Fax In Person 0 REMARKS: By: Connor Reuss EsGil 8/23 Enclosures: 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 DATE: AUG. 16,2018 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2018-0277 ✓• EsG1I A SAFEbuilt Company SET II PROJECT ADDRESS: 2051 PALOMAR AIRPORT ROAD PROJECT NAME: T.I. FOR IDEX HEALTH & SCEINCE • APPLICANT J' JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Aleksey Shafiro c/o WM AIA Telephone#: 619-564-5126 Date co d: V{i6/18' (b~ Email: ashafiro@waremalcomb.com Telephone Fax In Person By: ALI SADRE, S.E. Enclosures: EsGil 8/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 CARLSBAD CBC2018-0277 AUG. 16, 2018 PLUMBING AND MECHANICAL CORRECTIONS • JURISDICTION: Carlsbad • PLAN REVIEW NUMBER: CBC2018-0277 PLAN REVIEWER: Glen Adamek/Connor Reuss NOTE: Updated responses below are in bold font. DATE: 8/16/2018 SET: II GENERAL AND ARCHITECTURAL PME ITEMS 1. Please address all the actives proposed in the new Lab Rooms. Please provide cut sheets for the proposed overhead flow hoods located in the labs on sheetA.3. PLUMBING (2016 CALIFORNIA PLUMBING CODE) 2. Provide calculations to show compliance with CPC Table 422.1 "Minimum Plumbing Facilities" and occupant load CPC Chapter 4 Table "A". Please include the occupancy classification and the number of occupants. For the fixture calculations, include all the areas within the building impacting the restroom (not just the area within the tenant improvement). MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 3. Detail the primary and secondary mechanical condensate waste design: Pipe sizing, routing, and termination areas. CMC 310.0 & CPC 814.0. Please address the following items: • Please show the secondary condensate waste design for all mechanical units per CMC 310.2 • Primary condensate waste cannot connect to sink tailpieces (only lavatories). Please correct. CMC 310.6 • Please correct statement on sheet P1 .0 regarding the connection to the floor sink. An air gap is required (not a connection to the tailpiece). CMC 310.5 Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek/Connor Reuss at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DATE: JUNE 05, 2018 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2018-0277 ✓• EsG1I SET: I PROJECT ADDRESS: 2051 PALOMAR AIRPORT ROAD PROJECT NAME: T.I. FOR IDEX HEALTH & SCEINCE • APPLICANT • JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZ] The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZ] The applicant's copy of the check list has been sent to: D EsGil staff did not advise the applicant that the plan check has been completed. IZ] EsGil staff did advise the applicant that the plan check has been completed. Person contacted: 'leksey Shafiro c/o WM AIA Telephone#: 619-564-5126 Date contacted: ~/'-e (b4' ) Email: ashafiro@waremalcomb.com Mail Telephone Fax In Person 0 REMARKS: By: ALI SADRE, S.E. Enclosures: EsGil 5/24 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 CARLSBAD CBC2018-0277 JUNE 05, 2018 GENERAL PLAN CORRECTION LIST JURISDICTION: CARLSBAD 0277 PLAN CHECK#.: CBC2018- PROJECT ADDRESS: 2051 PALOMAR AIRPORT ROAD SCOPE OF WORK: T.I. FOR OFFICE; STORIES= ONE; HEIGHT= 24'; OCCUPANCY= B; CONSTRUCTION= V-B; SPRINKLERS= YES; TOTAL BUILDING AREA= NOT SPECIFIED; TOTAL T.I. AREAS= 11,000; DATE PLAN RECEIVED BY ESGIL: 5/24 REVIEWED BY: ALI SADRE, S.E. FOREWORD (PLEASE READ): DATE REVIEW COMPLETED: JUNE 05, 2018 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. CARLSBAD CBC2018-0277 JUNE 05, 2018 3. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? • Yes • No PLANS 4. Please specify the total floor area of the building on the cover sheet of the plans. 5. Please justify the total building areas versus allowable areas for this building for Type V-8 Construction. 6. Please show ceiling connection details and references on the plans for the suspended curtains from the ceiling, as per note #209, on Sheet A2..1. Also, indicate their maximum weight per lineal foot on the plans. 7. A portion of the counter, as per elevation 4/A6.1, should also be at least 36" in length with a maximum height of 34", for HC accessibility. Section 11 B-904.4.1. 8. Specify on the window schedule the glass type and thickness to show compliance with Section 2404. 9. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4: I.e .• see elevation 7/A6.1. etc. a) Fixed and openable panels of door assemblies. b) Fixed or operable panels adjacent to a door where the nearest vertical edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. c) Individual fixed or operable panels that meet all of the following conditions: i) Exposed area of an individual pane is greater than 9 square feet, and: ii) Exposed bottom edge is less than 18 inches above the floor, and: iii) Exposed top edge is greater than 36 inches above the floor, and: iv) One or more walking surfaces are within 36" horizontally of the plane of the glazing. 10. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in IBC Tables 307.1(1) and 307.1(2). 11. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 307.1 (1) and 307 .1 (2) possible. 12. Please provide a technical report to clearly classify the building as "B", "F", or "H" occupancy, due to presence of all the equipment, as identified on Sheet A3.0. Section 414.1.3. CARLSBAD CBC2018-0277 JUNE 05, 2018 13. Please label all the new versus existing HVAC equipment on the mechanical plans, or on the HVAC schedule. I.e., see Sheet M0.2. 14. Please complete all the blank bubbles on the door type elevations, Sheet A7 .1. 15. Please note on the plans that the occupants of this office renovation will have access to existing HC accessible sanitary facilities, subject to field verification. 16. On detail F/A8.1, please cross reference a connection detail for the bottom of the partition to the floor, UNO. STRUCTURAL 17. Please specify the maximum weight of all the new HVAC equipment on the roof & ceiling framing plans to be provided. 18. Please provide structural calculations for all the proposed new HVAC equipment over400-lbs. ASCE 7-10, Sec. 13.1.4.6(c)i. This applies to both the new equipment on the roof and ceiling framing plans, to be provided. ADDITIONAL 19. Please remove the stamp stating: "ISSUED FOR PLAN CHECK". 20. A reminder that all the revised plans & calculations need to be stamped and signed by the project engineer and/ or architect at back-check. MISCELLANEOUS 21. Please see attached for P/M/E corrections. 22. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil. Thank you. The Electrical and Energy designs are OKAY CARLSBAD CBC2018-0277 JUNE 05, 2018 PLUMBING AND MECHANICAL CORRECTIONS • JURISDICTION: Carlsbad • PLAN REVIEW NUMBER: CBC2018-0277 PLAN REVIEWER: Glen Adamek DA TE: 6/6/2018 SET: I GENERAL AND ARCHITECTURAL PME ITEMS 23. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. 24. Provide data on the proposed hazardous materials to be stored and used. Present the description of the hazardous materials in a format that coincides with the material classifications found in CBC Tables 307.1 (1) and 307.1 (2). • Clearly show the types of hazardous materials being stored or used. Provide a list of the proposed hazardous materials; include the material safety data sheets (MSDS), if applicable. • Clearly show the amounts for each type of hazardous material to be stored and in use. • Clearly show the locations in the building where each type of hazardous material is being stored or used. • Note: If hazardous materials are present in any amount, forward this information to the mechanical designer for design compliance with CMC Chapter 5. 25. Please address the types of materials to be machined in the Tooling Room. 26. Please address all the actives proposed in the new Lab Rooms. 27. Please provide the cut-sheets, listing data, and installation instructions for the machines to be installed in the Tooling Room. 28. Detail the location of the required roof access ladder and hatch (in the Tooling Room?) to provide the required access to new roof mounted mechanical equipment, as per CMC, Section 304.3 PLUMBING (2016 CALIFORNIA PLUMBING CODE) 29. Provide calculations to show compliance with CPC Table 422.1 "Minimum Plumbing Facilities" and occupant load CPC Chapter 4 Table "A". Please include the occupancy classification and the number of occupants. CARLSBAD CBC2018-0277 JUNE 05, 2018 30. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping, the drain, waste, and vent piping, gas piping, and the roof drains. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) 31. Clearly address if dust collection systems are needed for the machines to be installed in the Tooling Room. 32. Specify the make, model, type, and efficiency of the space heating and cooling systems in agreement with the energy design. 33. Detail the primary and secondary mechanical condensate waste design: Pipe sizing, routing, and termination areas. CMG 310.0 & CPC 814.0 34. Provide the exhaust and make-up air design for the occupancy type listed in Table 403.7. 35. Specify compliance with CMG 603.4.1 for length limitations for factory made flexible air ducts (5') and use (not to be used for rigid elbows or fittings). (Residential is exempt from this item) Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. CARLSBAD CBC2018-0277 JUNE 05, 2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: ALI SADRE, S.E. PLAN CHECK#.: CBC2018-0277 DATE: JUNE 05, 2018 BUILDING ADDRESS: 2051 PALOMAR AIRPORT ROAD BUILDING OCCUPANCY: B/V-B/SPR. BUILDING AREA Valuation Reg. PORTION ( Sq. Ft.) Multiplier Mod. T.I. 11000 46.51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance - 1997 UBC Buildin Permit Fee ... ' g __ _J 1997 UBC Plan Check Fee _""'_I VALUE Type of Review: Complete Review • Structural Only D Repetitive Fee , Repeats ..,., D Other 0 Hourly EsGII Fee ,__ __ ___,I Hr. @ * Comments: ($) 511,610 511,610 $1,181.761 Sheet 1 of 1 '-.. : .. l I D • D I 0 • 0