Loading...
HomeMy WebLinkAbout2052 CIMA CT; ; CB022723; Permit09-12-2002 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Miscellaneous Permit Permit No Building Inspection Request Line (760) 602-2725 CB022723 Job Address Permit Type Parcel No Valuation Reference # Project Title Applicant BAYERS ROOFING 215213THST92024 8585184797 2052 CIMA CT CBAD MISC 2164910200 $6 744 00 Subtype Lot# REROOF 0 WOOLSEY RES 2400 SF STD WT CONCRETE Status ISSUED Applied 09/12/2002 Entered By RMA Plan Approved 09/12/2002 Issued 09/12/2002 Inspect Area 2052 CIMA CT CARLSBAD CA 92009 0002 01 CGP 02 128 00 Total Fees $12800 Total Payments To Date $000 Balance Due $12800 Miscelaneous Fee #1 Miscelaneous Fee #2 Additional Fees TOTAL PERMIT FEES PERMIT FEE $12800 $000 $000 $12800 Inspector FINAL APPROVAL Date / h~l/h.1 -Li Clearance NOTICE Please take NOWCEtlpt approval of your project includes the Imposition" of fees dedications reservations or other exactions hereafter collectively referred to as "fees/exactions TOU have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave Carlsbad CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By Date -/s Address (Include Bldg/Suite *)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units s Parcel #Existing Use Use of Work SO FT * of Bedrooms if of Bathrooms Name Address City State/Zip Telephone *Fax* Name Address City State/Zip Telephone 9 * ? -Address'*'Name City"State/Zip (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged Any violation oMectiiBa 7031 5 by any applicant for a permitsubjects thejumHcsnt to a civil penalty ghnotjnou than five hundred dojlajs [t5(X>L) Nah State License * Address «? License Class City City Business License f _ Designer Name State License # Address City State/Zip Telephone Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued Q I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker's compensation insurance earner and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS l»100] OR LESS) tf7J__ CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as Tobecome subject to the Workers Compensation Laws of California WARNING Falun Mjftcure worken compensation coverage Is unlawful and shaft subject an employer to criminal penalties and dvB fines up to one hundred thousand dotes (*UMOOO) JnAnon toi«j£cost of compensation damages as provided for hi Section 3706 of theJ«bor code Interest and attorney s fee* SIGNATURE V.JJfoZ'fsi^ Or?***—— DATE 7 fC I hereby affirm that I am eMntpt from the Contractor's License Law for the following reason O I «« owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden ofproving that he did not build or improve for the purpose of sale) D I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) ~~~~»». I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement O YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) _ _^__^___^_^_^^_^_______^_^_____^^^____ 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) _ _ PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? O YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES A RNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commanjed within 180 days torn the date of such permit or If the building or work authorized by such permit is suspended or abandoned at any time after the work is commenpffffor a M»>r of 180/Ws (Section 106 4 4 Uniform Building Code) /X^^C"*^ I/S4t* DATE YELLOW Applicant PINK Finance APPLICANT S SIGNATURE City Of Carlsbad SUPPLEMENTAL BUILDING PERMIT APPLICATION FOR REROOFING 1 JOB ADDRESS 205^ (*. '/* + tf£ f# I TYPE OF BUILDING RESIDENTIAL 0^ COMMERCIAL 3 ROOF SLOPE RISE y/^mches in 12 inches 4 NUMBER OF EXISTING ROOF COVERING,(circle one) @) 2 5 TYPE OF EXISTING ROOF,. COVERING^C^SHEATHING *6 NEW ROOF MATERIAL/agfrflr CLASS_£L WEIGHT PER SQUARE 7 -NUMBER OF SQUARES 8 TRADE NAME l-~Z0/e MANUFACTURER. 9 ROOF SYSTEM LISTING ULNo ICBO No 10 IS THE EXISTING STRUCTURAL DESIGN SUFFICIENT TO SUSTAIN THE WEIGHT OF THE PROPOSED ROOFT/^YES^ NO All roof coverings are required to be CLASS A Combustible roof coverings of any type or classification are prohibited I understand the following inspections are required 1 Tear Off/Pre-mspection prior to install new roof covering 2 Final Inspection I agree to provide a ladder extending at least 2 rungs above the roof for inspection Signature XJ_^tffo^rS*!}^ Date. Contractor Pv Owner Contractor Name_ *6 - Rolled Roofing, Standard/Lite Tile, Asphalt/Comp Fiberglass, Built up, Other City of Carlsbad Bldg Inspection Request For 09/24/2002 PermiW CB022723 Title WOOLSEY RES 2400 SF STD WT Description CONCRETE Type MISC Sub Type REROOF Job Address 2052 CIMA CT Suite Lot 0 Location APPLICANT BAYNES ROOFING Owner WOOLSEY JAMES D&CATHERINE A Remarks Inspector Assignment PY Phone 8585184797 Inspector Total Time CD Description 19 Final Structural Act Comments Requested By JEFF Entered By GIOVANNA Associated PCRs/CVs Inspection History Date Description Act Insp Comments 09/20/2002 15 Roof/Reroof AP PY SHEATHING INVOICE Myen Engineering 1290 Ridgeview Way Bonita, CA 91902 (619)421-4211 Date TO cr . cA- PROJECT DESCRIPTION a Reroofiny Prp>jp?t - Dingle Famflv Myen Engtneenng BurtonS Myers RCE# 24928 Total Amount Due S27S.OO Ill STRUCTURAL CALCULATIONS FOR A REROQFINCVPRQJECT LOCATION. 7 r or OWNER. CONTRACTOR. ST ENOINEER. Burton S Myers 1290RjdgcviewWay Bomta, CA 91902 (619)421-4211 RCE 24928 Exp 12-31-0$* The work will consist of removing the existing wood shake roof, down to the spaced sheeting Adding plywood sheeting (or equal), additional braces, rafters, and gusset aes, ifnedejcLand a new tile roof per the manufacturers recommendations , ti^ IT -4O |SS j- M t r 11 M \ t \ 1- ' I as?4- _ 7 -300 M ii 7EJU . IL i i ?-'!«. i i ;/ • Mini! (I i zii f h-Oti- ! .1 kl ~ Ci^lJIL ,,LJ i ' ) s *• t >» GENERAL CONDITIONS 1 THE SOLE PURPOSE OF THESE STRUCTURAL CALCULATIONS IS TO DETERMINE THE GENERAL CONDITIONS OF THE OVER ALL STRUCTURAL ROOF SYSTEM AND TO DETERMINE WHETHER THE ROOF SYSTEM CAN STRUCTURALLY SUPPORT THE INSTALLATION OF THE NEW PROPOSED ROOF MATERIALS ,* 2 THE INSPECTION PORTION OF THE CALCULATIONS WILL CONSIST OF DETERMINING THE SIZE MEMBERS THAT ARE NEEDED TO SUPPORT THE NEW ROOF SYSTEM. IN THOSE CASES WHERE THE-EXISTING ROOF SYSTEM DOES NOT MEET THE MINIMUM BUILDING CODE REQUIREMENTS, RECOMMENDATIONS WILL BE MADE TO ADD ADDITIONAL BRACES SUPPORTS OR OTHER STRUCTURAL MEMBERS TO INCREASE THE VALUES OF THE ROOF SYSTEM. 3 THE INSPECTION IS GENERAL IN SCOPE, AND DOES NOT INVOLVE INSPECTING EACH INDIVIDUAL MEMBER, 4 THE INSPECTION DOES NOT INVOLVE LOOKING FOR DAMAGE CAUSED BY TERMITES, DRYROT, OR OTHER SOURCES 5 DURING THE COURSE OF THIS INSPECTION, CERTAIN AREAS OF THE ROOF MAY NOT BE ACCESSIBLE THOSE AREAS SHOULD BE OBSERVED AFTER THE EXISTING ROOF IS REMOVED PRIOR TO INSTALLING THE NEW ROOF 6 PLOT PLAN - THE PURPOSE OF THIS SKETCH IS TO SHOW THE OUTLINE OF ALL THE STRUCTURES WHICH WERE EVALUATED, AND WHERE THE TYPI ROOF SECTIONS WERE OBSERVED IN THE STRUCTURE ALL DIMENSION! APPROXIMATE IF THE OUTLINE OF THE STRUCTURE IS NOT SHOWN ON THIS PLAN, THE STRUCTURE WAS NOT EVALUATED 7 ROOF SHEETING - UNLESS SPECIFIED IN THE CALCULATIONS, THE ROOF SHEETING WILL BE A MINIMUM 7/16" CDX PLYWOOD 7/16" OSB (NER - 124) OR EQUAL THE PURPOSE OF THE ROOF SHEETING IS TO PROVIDE A NAILING /* SURFACE FOR THE NEW TELE ROOF THE ROOF SHEETING MAY BE APPLIED DIRECTLY OVER THE EXISTING SPACED SHEETING THE ROOF SHEETING SHOULD BE ATTACHED WITH 8 D'S @ 6" O/C ALONG THE EDGES, AND @ 12" O/C IN THE FIELD THE CONTRACTOR SHOULD ATTEMPT TO NAIL THE ROOF SHEETING TO THE EXISTING SPACED SHEETING WHERE POSSIBLE INSTEAD OF NAILS, STAPLES MAY BE USED PER TABLE 25-Q FOOTNOTE #9 8 RAFTER JOISTS/GARAGE CEILING JOISTS - WHEN RAFTER JOISTS OR GARAGE CEILING JOISTS ARE USED, THEY SHALL BE PLACED ON ALL RAFTERS, NOT EVERY OTHER RAFTER. MAXIMUM SPACING FOR RAFTER JOISTS IS 24" O/C 9 PURLINS - IF PURLINS ARE USED AS PART OF THE SUPPORT SYSTEM TO REDUCE THE SPAN OF THE ROOF RAFTERS, THE FOLLOWING CONDITIONS MUST BE MET A. PURLINS MUST BE EQUAL OR LARGER IN SIZE THAN THE RAFTERS THEY SUPPORT B THE MAXIMUM SPAN FOR2x 4 PURLINS SHALL BE 4 FEET C THEMAXIMUM SPAN FORTHE 2x6 OR LARGER PURLINS SHALL BE 6 FEET THE STRUTS WfflCH SUPPORT THE PURLINS AND CARRY THE LOADS TO BEARING WALLS, SHALL BE A MINIMUM SIZE OF 2 x 4, AND THE UNBRACED LENGTH SHALL NOT EXCEED 8 FEET 10 THIS HOUSE WAS MEASURED AND INSPECTED UNDER MY DIRECTION TO DETERMINE THE TYPE AND SIZE OF THE STRUCTURAL MEMBERS (COUNTY OF /* SAN DIEGO) 11 TfflS ENGINEERING REPORT (INSPECTION AND CALCULATIONS) IS PRIMARILY CONCERNED WITH THE ROOF SYSTEM. IT HAS TO BE ASSUMED THAT THE VERTICAL STRUCTURAL SUPPORT MEMBERS AND THE FOUNDATION SYSTEM WAS ORIGINALLY DESIGNED AND CONSTRUCTED TO THE BUILDING CODES AND ARE SUFFICIENT TO SUPPORT THE ROOF SYSTEM. (REFERRED TO IN THE SECTION DRAWINGS), THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE SIZE AND SPACING OF THESE RAFTERS, AFTER THE ROOF IS REMOVED 13 THE CITY OF SAN DIEGO REQUIRES THAT CODE APPROVED SMOKE DETECTORS BE INSTALLED WHEN A REPAIR OR ALTERATION IS MADE TO A RESIDENTIAL UNIT WHICH EXCEED $1,000 00 A CODE APPROVED SMOKE DETECTOR IS REQUIRED TO BE INSTALLED IN EACH SLEEPING ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA (SECTION 1210 - UNIFORM BUILDING COD]