HomeMy WebLinkAbout2052 CORTE DEL NOGAL; A; CB033042; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No CB033042
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Ti*le
2052 CORTE DEL NOGAL CBAD St A
Tl Sub Type
2130610600 Lot#
$20,000 00 Construction Type
RED DOT NET-INSTALL RACKS IN
WAREHOUSE
INDUST
0
NEW
Applicant
DEI LLC
C/O LAW OFFICES OF JON LADD
11440 WEST BERNARDO CT #214
SAN DIEGO CA 92127
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Plan Check#
Owner
DEI LLC
C/O LAW OFFICES OF JON LADD
11440 WEST BERNARDO CT #214
SAN DIEGO CA 92127
ISSUED
11/05/2003
RMA
12/16/2003
12/19/2003
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$17669 Meter Size
$0 00 Add'l Reel Water Con Fee
$11485 Meter Fee
$50 00 SDCWA Fee
$0 00 CFD Payoff Fee
$4 20 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$000 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$345 74
Total Fees $345 74 Total Payments To Date $5000 Balance Due $295 74
1483 1.2/19/03 0002 0.1
CGP
02
74
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
f PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK
EST VAL
Plan Ck Deposit
Validated
Date
Pin Oor /f/cr
at this address!) A 11//V;//V7 rtnmAddress (include Bldg/Suite tt)Business Name (at this addgjjSj) A JJ./Q'S/OS 0002 OJ OP
Unit No Phase NJpGiHtotal # ofLegal Description Lot No Subdivision Name/Number
Assessor's Parcel #Existing Use Proposed Use
Name Address
CONTRACTOR - COMPANY NAME
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter, improve, demolish or repair any structure prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged
exemption Anyjujolation of_SectionJJ031 5 by any applicant for.a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500])
^OQfXL&tb. J»o<^. &Z^2-/ VW^0K> !>£.•**fe Carkka^ OA
Name
State License #
Address
License Class
City State/Zip
City Business License #
Teephone #
Designer Name Address City State/Zip Telephone
State License #
6'": WORKERSiCOMPENSAfibN'- '"^"" v-:: ',. ""ms" '••' ^*- *"'*svss* ""!:'"!"" ' vrfv* ./a,', .1 . "I,
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
C] I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
d I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 000), in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees
SIGNATURE DATE
OWNER-BUILDER DECLARATION ?=PN
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
f~l I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES I~|NO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION f OH NON-RESIDENTIAL BUILDING1PERMITS ONLY; sdisuM£?'T .„:** if :
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? l~l YES l~l NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? l~l YES l~| NO
Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? l~l YES l~l NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8. CONSTRUCTION LENDING AGENCY .:;*.••' '**;• •• •. ':'|t: ''SP^ <& ' '' *' •,»=•" :;",.:•••;•.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER'S NAME _ LENDER S ADDRESS _ _
"9 APPLICANT:CERTIFICATl6N ..... 'r:'"'" ..... ":"':' '" " ...' -.'••: ,, ...... i, .. Mf«~, ": ' i:!*
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is notfb/nmenced witim 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is corriinced/Jpr a perjod^onf^djay^ (Section 10644 Uniform Building Code)
} LMAPPLICANT'S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad Bldg Inspection Request
For 02/03/2004
Permit* CB033042
Title RED DOT NET-INSTALL RACKS IN
Description WAREHOUSE
Inspector Assignment TP
Type Tl
Job Address
Suite
Location
APPLICANT DEI LLC
Owner DEI LLC
Remarks
Sub Type INDUST
2052 CORTE DEL NOGAL
A Lot 0
Phone 6197334007
Inspector ^
T
Total Time
CD Description
19 Final Structural
Act Comment
Associated PCRs/CVs
Requested By ROB
Entered By ROBIN
Inspection History
Date Description Act Insp Comments
01/26/2004 19 Final Structural NR TP DOOR LOCKED, NO RECP
12/23/2003 14 Frame/Steel/Boltmg/Weldmg CO TP BASE PLATE BOLTS
12/23/2003 19 Final Structural CO TP
EsGil Corporation
In (Partnership with government for (RuiUing Safety
DATE 12/15/03 a APPLICANT
JURISDICTION City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 03-3042 SET II
PROJECT ADDRESS 2052 Corte Del Nogal Ave.
PROJECT NAME Storage Racks for RedDotNet
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) , / Fax #
Mail Telephone Fax In Person
A] REMARKS City to field verify that the paro'of travel from the handicapped parking space to the
rack area and the bathroom serving thairack area comply with all the current disabled access
requirements '
By David Yao Enclosures
Esgil Corporation
D GA D MB D EJ D PC 12/8 tmsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
EsGil Corporation
In Partnership with government for <BuiC<£ing Safety
DATE 11/18/03 a APPLICANT
JURISDICTION City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 03-3042 SET I
PROJECT ADDRESS 2052 Corte Del Nogal Ave.
PROJECT NAME Storage Racks for RedDotNet
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Lori Simpson 5993 Avenida Encmitas Carlsbad CA 92008
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Lori Simpson Telephone # (760)931-8026 (
Date contacted f<ltflo'i>(by (^ ) Fax #
Mail "Telephone Fax^ In Person
REMARKS
By David Yao Enclosures
Esgil Corporation
D GA D MB D EJ D PC 11/12 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
City of Carlsbad 03-3042
11/18/O3
, ... GENERAL PLAN CORRECTION LIST
JURISDICTION City of Carlsbad PLAN CHECK NO O3-3O42
PROJECT ADDRESS 2052 Corte Del Nogal Ave.
DATE PLAN RECEIVED BY DATE REVIEW COMPLETED
ESGIL CORPORATION 11/12 11/18/03
REVIEWED BY David Yao
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform .Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
« Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will
route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire
Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining
sets of plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
Q Yes Q No
City of Carlsbad O3-3042
11/18/03
1 Provide a rack layout plan showing the location of all racks ...
2 Only the storage racks are included in this plan review
3 Provide a statement on the Title Sheet of the plans that this project shall comply with
Title 24
4 UBC Section 107 2 requires the Building Official to determine the total value of all
construction work proposed under this permit Please provide a signed copy of the
designer's or contractor's construction cost estimate of all work proposed
5 City to field verify that the path of travel from the handicapped parking space to the rack
area and the bathrooms serving the rack area comply with the current disabled access
requirements Title 24, Part 2
6 Obtain Fire Department approval for groups F, M and S occupancy storage per UBC
Sections 306 8, 309 8 and 311 8
7 Indicate the clearance from the new racks to the existing building walls and building
columns
8 Note on the plans that the rack design loads will be posted per Section 2222 5
9 Provide forklift protection per Section 2222 5 (or check the exception)
Recheck the "pallet" racks as follows
10 Recheck all connections on sheet 03-1476A as follows
a) The rivet bearing capacity is only dtFu = 0 406(0 0747)65 = 2 kips
b) Provide calculations for all beam to bracket weld capacities per Section 2330
(allowable weld stress is the member thickness times 26 ksi times 1 33, or the
weld stress, whichever is lower)
c) Check the bracket maximum weak axis moment
11 Provide calculations for the column weak axis bending plus axial for transverse seismic
loading The axial load is the maximum compression load at the base from vertical plus
seismic overturning The column moment will probably be maximum for the lateral load
from the base plate to the first diagonal brace (not only to the first horizontal member)
12 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform
the plan review for your project If you have any questions regarding these plan review
items, please contact David Yao at Esgil Corporation Thank you
City of Carlsbad 03-3042
11/18/O3
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad
PREPARED BY David Yao
PLAN CHECK NO O3-3042
DATE 11/18/03
BUILDING ADDRESS 2052 Corte Del Nogal Ave.
BUILDING OCCUPANCY TYPE OF CONSTRUCTION
BUILDING
PORTION
storagae racks
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
cb
Valuation
Multiplier
By Ordinance
Reg
Mod
estimate
VALUE ($)
«
20,000
20,000
Bldg Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review 0 Complete Review
Q Repetitive Fee^ j Repeats
D Other
r—| Hourly
Structural Only
Hour
Esgil Plan Review Fee
$17669
$11485
$9895
Comments
Sheet 1 of 1
macvalue doc
Carlsbad Fire Department 033042
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report 11/19/2003
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by
Name
Address
City, State
MANSOUR ARCH
5897 OBERLIN DR
SAN DIEGO CA 92121
Plan Checker
Job Name
Job Address
Job # 033042
Red Dot Net
2052 Corte el Nogal
Bldg # CB033042
Ste or Bldg No A_
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
D Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
D Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1st 2n<1 3rd
033042 FD File #
Other Agency ID
SEIZMIC
MATERIAL HANDLING ENGINEERING
EST 1985
STORAGE RACKS
DRIVE IN RACKS
CANTILEVER RACKS
MEZZ/WES
CONVEYORS
CAROUSELS
STEEL SHELVING
MOVABLE SHELVING
STORAGE TANKS
MODULAR OFRCES
GONDOLAS
BOOKSTACKS
CITY APPROVALS
STATE APPROVALS
PERMITTING SERVICES
PRODUCT TESTING
FIELD INSPECTION
SPECIAL FABRICATION
ALASKA
ARIZONA
CAUFORNIA
COLORADO
IDAHO
MISSOURI
NEVADA
NEW MEXICO
CREGCN
PENNSYLVANIA
UTAH
WASHINGTON
SEISMIC ANALYSIS
OF STORAGE RACKS FOR
RED DOT
2052 CORTE DEL NOGAL
CARLSBAD CA
#03-1476
161 ATLANTIC STREET POMONA CA 91768 TEL (909)869-0989 FAX (909)869-0981
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
TABLE OF CONTENTS
DESCRIPTION PAGE #
COVER SHEET 1
TABLE OF CONTENTS 2
SCOPE 2
PARAMETERS 3
CONFIGURATIONS 4
COMPONENTS & SPECS 5
LOADS AND DISTRIBUTION 6
LONGITUDINAL ANALYSIS 7
COLUMN 8
BEAM 9
BEAM TO COLUMN 10
BRACING 11
OVERTURNING 12
BASEPLATE 13
SLAB & SOIL 14
SCOPE
THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH
THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES
THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY,
WITHOUT ANY FIELD WELDING
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO,OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_RF DATE.10-28-2003
PARAMETERS
STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH
DIRECTIONS WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN
ANY ADJACENT BAYS
THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYZED IN BOTH
LONGITUDINAL AND TRANSVERSE DIRECTION
STABILITY LONGITUDINALLY IS DEPENDANT ON BEAM TO COLUMN MOMENT,
WHILE THE BRACING ACT TRANSVERSELY
1 COLUMN
2 BEAM
3 BEAM TO COLUMN
4 BASEPLATE
5 HORIZONTAL BRACING
6 DIAGONAL BRACING
7 BACK CONNECTOR
TRIBUTARY AREA
I
TRANSVERSE
I I
LONGITUDINAL
TOP VIEW
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO,OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
CONFIGURATIONS
39"
144"52"
53"
TYPE1
1,200 Ib
1,200 !b
1,200 Ib
96"
44"
42"'42"-7
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
TYPE1
SPECIFICATION
- MAIN STEEL 50000 PSI
- BASE PLATE STEEL 36000 PSI
- ANCHOR - WEDGE TYPE 1/2 x 2-1/4 MIN EMfeED
-FLOOR SLAB 4" X 2000 PSI REINFORCED 144" 52"
- SOIL BEARING PRESSURE 1000 PSF
-SEISMIC ZONE 4
- TYPE = INTERCONNECTED UNITS
1,200 Ib 134#
SECTION AXIAL FORCE MOMENT
lu = 96"
BEAM MOMENT
171#
hMI
1
1
3
JED
44" E
-)
£
9"
C
2"
V
3"
3
1,200 Ib
2
1.200 Ib
1
^ /-\ /-i ii
'»
/
98#
/
^
49#
/
]
e
4"
'
4"
/
'
,
12
62
1 1,905 Ib 3,596 in Ib . cnn ., . ,
2 1270 Ib 3:023 mlb ^,509 in b <-s d conn
3 635 Ib 1.311 mlb ?,367 ,n b <-s d conn
1 ;856 in Ib <-std conn
TYPE 1 DESIGN LOAD = 1200#
BASE PLATE
V
8 X 5 X 375
Mbase = 3595 in Ib
OVERTURNING
V
ANCHOR STRESS = 0 01
# OF ANCHORS = 2
V
COLUMN
COLUMN
3X3X12GA(LM30)
STRESS =0 20 4
MAX
BRACING
HORIZONTAL -
1 1/2X1 1/4 X 14 G
STRESS = 0 07
v! DIAGONAL
A 11/2X11/4X1
STRESS = 0 1 '
BEAM
V
-1/2X2-3/4X1 4GA(LBF454)
LOAD/LEVEL = 5,071 Ib
BEAM IS O.K.
SLAB & SOIL
V V
4 GA PUNCT STRESS = 0 38
1 BENDING STRESS =0 31
SEIZMIC
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 - FAX (909)869-0981
161 ATLANTIC AVENUE • POMONA • CA 91768
I CALCULATED BY.RF DATE.10-28-2003
LOADS & DISTRIBUTION: TYPE 1
LIVE LOAD PER SHELF (BASED ON CLIENT SUPPLIED DATA) = wLL
DEAD LOAD PER SHELF > = wDL
SEISMIC BASE SHEAR DETERMINED IN ACCORDANCE WITH SECTION 1630 2 1 OF THE 2001 CBC = V
WHERE V = (( 2 5 x Ca x I) / R) x Wtotal
Wtotal = (wLU2 + wDL)
SEISMIC ZONE = 4 :
Ca = 0 44Na WHERE Ca = 6 44Na AND Na = 1
l= 100
SOIL COEF = Sd
R (LONGITUDINAL) = 56
R (TRANSVERSE) = 44
wDL = 70 LB
n = 2
DEPTH= 42 in
LONGITUDINAL DIRECTION
Vlong = [2 5*0 44*1'(3600/2+210)/5 6]/1 4
= 282 Ib
Fi = V Whi/IWh
TRANSVERSE DIRECTION:
Vtrans = [2 5*0 44*1*(3600/2+210)/4 4]/1 4
= 359 Ib
Fi = V Whi/ZWh
(SECTION 2228 5 2 )
(SECTION 2228 5 2 )
INTERCONNECTED UNITS
SEISMIC DISTRIBUTION
LEVEL h
IN
WEIGHT
LB
HEIGHT
IN
WXH
LB-IN
Fi (long)
LB
Fi (trans)
LB
Mot
IN-LB
1
2
3
530
520
390
1,200
1,200
1,200
530
1050
1440
63,600
126,000
172,800
495
981
1345
630
1248
171 1
3,338 5
13,1033
24,644 8
144 IN 362,400 282 LB 359 LB 41,087 IN-LB
TOTAL FRAME LOAD = 3810 LB
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
LONGITUDINAL ANALYSIS TYPE 1 ;
THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE
COLUMNS ASSUMED AT MID-HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE
THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR
CLOSER TO THE BASE (OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT
CARRY MOMENT)
Vlong = 2 * Vcol
Vcol
F 1 = 25 Ib
F2= 49 Ib
F3= 67 Ib
282 Ib
141 Ib
53 in
Beam 10
Col Conn
Col to slab
BASE PROVIDE PARTIAL FIXITY SEE BASE PLATE SHT
Mbase = 3595 in Ib j
i
Mupper + Mlower = Mconn'R' + iMconn'L'
Mconn'R' = Mconn'L' !
Mconn * 2 = Mupper + Mldwer
Mconn = [Mupper + Mlower]/2
RESULTING FORCES ON COLUMN
SECTION AXIAL LOAD MOMENT ' Mconn
35951
2
3
1905
1270
635
3022
1311
4509
3366
Mupper
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 « FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.8
CALCULATED BY.RF
OF 1 4
DATE 10-28-2003
COLUMN ANALYSIS TYPE 1
COLUMN IS ANALYZED PER AISI COLD-FORMED STEEL DESIGN MANUAL
Pmax = 1,905 Ib Mmax = 3,596 in Ib
Kxlx/rx = 12*51/13= 471 <-GOVERNS
Kyly/ry = 8 * 44 / 1 079 = 32 6
Cc = (2jiA2E/Fy)A 5
= 1070
SINCE Kl/r <= Cc,
Fa = 522Fy - [(kl/r*Fy)/1494]A2
= 23,618 psi
fa = Pmax/Area
= 2,087 psi
fb = Mmax/Sx
= 3,491 psi
fa/Fa =009 <= 15
fa/Fa+fb/Fb <= 1 33
Fb = 6*Fy = 30,000 psi
fb/Fb = 0 12
COMBINED STRESS = 0 20
B
C
SECTION PROPERTIES
A = 3"
C = 75"
E = 0"
t1 = 1046"
B = 3"
D = 0"
Wt = 0#
t2 = 0"
Area = 913"A2
|X = 1 544"A4 ly = 1 064"A4
Sx = 1 03"A3 Sy = 68"A3
rx = 13" ry = 1 079"
52"
51"
44"
44"
Front View Side View
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_RF DATE.10-28-2003
BEAM ANALYSIS :TYPE 1
BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACITY TO STABLIZE THE SYSTEM,
ALTHOUGH IT DOES NOT PROVIDE 100% FIXITY THUS, THE BEAMS WILL BE ANALYSED ASSUMING
THEY HAVE PINNED ENDS FOR THE COMPUTATION OF BEAM TO COL MOMENT CAPACITY, THE
PARTIAL FIXITY OF THE BEAM,(ASSUMED AT AN ARBITRARY 25% OF THE FIXED END MOMENT OR
2,000 in Ib WHICH EVER IS SMALLER) WILL BE ADDED
lact = 96 0 in
Imax = [1950 + 1200(M1/M2)]b/Fy
SINCE M1/M2 = 1 0
Imax = 3150*b/Fy = 173 in
SINCE Imax > lact Fb = 60Fy = 30,000 psi
MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON
1) BENDING CAPACITY
M = Sx* Fb = wlA2/8
= 34230m Ib
CAPACITY = 2(8*M/I) - 5071 Ib
2) MAXIMUM ALLOWABLE DEFLECTION (L/180)
A = 5wlA4/384EI
CAPACITY = 2[(384EI)/(5*180*IA2)] = 7518lb
MAXIMUM STATIC LOAD PER LEVEL IS 5,071 Ib.
ALLOWABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL
Mstatic = wlA2/8 = LIVE LOAD*L/(2*8) Mallow(static) = Sx
Mimpact = 1 125*Mstatic Mallow(seismic) = 1 33 '
Mseismic = Mconn (SEE LONG ANALYSIS)
LEVEL Mstatic Mimpact Mallow Mseismic Mallow
1 125 Mstatic (Static) (seiSITIIC)
1 7200 8100 34229 4509 45639
2 7200 8100 34229 3366 45639
3 7200 8100 34229 1855 45639
Sx = 1 141 in A3
Ix = 2 753 in A4
' Fb
Sx •
1 5"
Fb
RESULT
GOOD
GCCD
GOOD
SEIZMIC
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.10 OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA91768
CALCULATED BY.RF DATE.10-28-2003
BEAM TO COLUMN ANALYSIS:
Mupper
CONNECTION CAPACITY DEPENDS ON THE FOLLOWING PARAMETERS
1) SHEAR CAPACITY OF STUDS
Mconn
STUD DIAMETER= 7/1 6 IN
Fy= 55,000 PSI
Pmax-shear= 0 4 * Fy * Area
= 04* 55000 PS! * (0 4375 IN)A2 * TT/4
= 3,307 3 LB
2) BEARING CAPACITY ON COLUMN
Fu= 65,000 PSI
Pmax-brg= Bearing Area * Fbeanng
= (tmm * thickness) * (1 0 * Fu)
= (0 4375 IN * 0 12 IN) * (1 0 *65000 PSI)
= 3,41 2 5 LB >33073LB
3) MOMENT CAPACITY OF BRACKET
Mconn
Mlower
Mcap= Sbracket * Fbendmg
= 011 IN*3 * 0 66 * Fy
= 3,993 IN-LB
C= Mcap/0 75 = 1 67 * PI
THUS, P1=0798*Mcap
= 3,186 IN-LB < 33073 LB
THUS, GOVERNING VALUE IS THE MIN VALUE OF PI,
P1-eff= 3.186LB
Mconn-allow= P1*4 5 IN + P2*2 5 IN + P3*0 5 IN
= 594*P1-eff* 1 33
= 25,236 IN-LB > Mconn max, OK
3-1/4"
\
C= PI + P2 + P3
= P1+P1*(2 5/4 5)+P1*(0 5/4 5)
= 1 67*P1
t-7 go Sbracket= 0110
1-5/8"
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.11 OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
TRANSVERSE ANALYSIS BRACING TYPE 1
IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND
COMPRESSION IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE
ON THE DIAGONAL MEMBER AS IT WILL GOVERN
DIAGONAL BRACING COMPRESSION MEMBER
Ldiag = [(L-6)A2+(D-2*Bcol)A2]A 5
= 523
Vdiag =Vtrans * Ldiag / D
= 447#
kl/rmm = [ 1 * 52 3 ] / 404
= 1295
Fa =[12jrA2E]/[23(kl/r)A2]
= 8895 psi
fa/Fa =Vdiag/(Area*Fa)
= 017
Dl= 523"
D= 42"
L= 44"
DIAGONAL AND
HORIZONTAL BRACING
W
-T- Area= 288 "A2
t rmin= 404 "
H t= 0747 "
W= 1 5 "
T H= 1 25 "
PROJECT.
FOR
RED DOT
CSGOODALE
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE • POMONA • CA 91768
NO,14
CALCULATED BY_
DC
""DATE 10-28-2003
OVERTURNING ANALYSIS: TYPE 1
ANALYSIS OF OVERTURNING WILL BE BASED ON SECTION 2228 7 1 OF THE 2001 CBC
DEPTH = 42 in
TOP LEVEL HEIGHT = 144 in
FULLY LOADED
Total Shear= 359 Ib
Mot= Z(Fi*hi)*1 15
= 47,250 m-lb
Mst = !(Wp+wDL)*D/2
= (3600lb + 210lb)*42m/2
= 80,010 m-lb
Puplift= 1(Mot-Mst)/Depth
= (47250-80010)/42
= 0 Ib <= NO UPLIFT
TOP SHELF LOADED
SHEAR = 120lb
Mot = Vtop * ht
= 120 Ib* 144in
= 17,229 m-lb
Mst = (Wp+wDL)*D/2
= (1200lb + 210lb)*42/2
= 29,610 m-lb
ELn
ELS
EL 4
ELS
Puplift = 1 (Mot - Mst)/Depth
= Olb
ANCHORS
QUANTITY= 2
PULLOUT = 773 LB
SHEAR= 1586LB
<= NO UPLIFT
<=== 33 1/3% INCREASE FOR SHORT TERM LOADING DUE TO SEISMIC FORCES
<=== 33 1/3% INCREASE FOR SHORT TERM LOADING DUE TO SEISMIC FORCES
Eq = (Ps/Pt)A5/3 + (Vs/Vt)A5/3 <; 1 0
INTERACTION EQUATION
FULLY LOADED = (0 LB/1546 LB)A5/3 + (179 LB/3172 LB)A5/3
= 0 01 < 1 0 OK
TOP SHELF LOADED = (0 LB/1546 LB)A5/3 + (60 LB/3172 LB)A5/3
= 0 00 < 1 0 OK
USE (2) 1/2"0x2-1/4"MIN EMBED RAMSET/REDHEAD (I C B O #1372) OR APPROVED EQUAL
PULL OUT CAPACITY IS THAT OF WITHOUT SPECIAL INSPECTION
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO,13 OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 « FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY RF DATE.10-28-2003
BASE PLATE :TYPE 1
BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL
LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY)
THERE ARE 3 CRITERIA IN DETERMINING Mb THEY ARE 1) MOMENT CAPACITY OF THE BASE PLATE,
2) MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3) Vh/2 (FULL FIXITY) Mb IS THE SMALLEST
VALUE OBTAINED FROM THE 3 CRITERIA ABOVE
Pcol = 1905 Ib
Mb = 3595 in Ib
B = 8 in D = 5 in
b = 3 in
t = 375 in
b1 = 25 in
P/A = Pcol/(D*B) = 47 62 psi
M/S = Mb/((D*BA2)/6) = 6741 psi
fb2 = 2b/B*fb = 42 13 psi
fb1 = fb-fb2 = 25 28 psi
Mbase = wb1A2/2 = b1A2/2[ fa + fb1 + 67fb2]
Mbase = 315 6 in Ib
Sbase = 1T2/6 = 0 0234 in A3
Fbase = 75Fy * 1 33 = 36000 psi
fb/Fb = Mbase/(Sbase*Fbase) = 37
ANCHOR TENSION
IMo = 0
T*d2=[Mbase- Pcol*b/2]
T - Mbase/d2 - Pcol*b/2d2
T = 164 Ib
Pcol
fbl
Mh
d
1
^
T
asef
*A, ,.Co,7
Pcolr
* Mbase
' b
V x jOL'5
d2
dl
| Mbasi
t~~3T
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.14 OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
SLAB AND SOIL TYPE 1
THE SLAB IS CHECKED FOR PUNCTURE STRESS IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED TO
DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND HENCE, WILL ACT AS A FOOTING
(a) PUNCTURE
Pmax = 1 4 DEAD LOAD + 1 7 LIVE LOAD
Pmax = 14* Pool + 17* (Mot/d)
= 4,579 Ib
894 psi
1360 in A2
0 38
Fpunct = 2*sqrt(f'c)
Apunct = [(w+t/2)+(d+t/2)]*2*t
fv/Fv = Pmax/(Apunct*Fpunct)
(b) SLAB TENSION
Asoil = Pmax/(1 33 * fsoil) = 3 43 ft A2
= 495 in A2
L = sqrt(Asoil) = 22 2 in
B = sqrt(w*d) + t = 103 m
b = (L-B)/2 = 6 0 m
Mconc = wbA2/2 = (1 33*fsoil*bA2)/(144*2)
= 1643 m Ib
Scone = 1*tA2/6 - 2 67 m A3
Fconc-= 50 *sqrt(fc) = 201 25 psi
fb/Fb = Mconc/(Sconc*Fconc) = 0 31
L
BASE PLATE
w = 8 in
d = 5 in
CONCRETE
t = 4 in
f'c = 2000 psi
SOIL
fs = 1000 psf
' h ,' B
t
^
/
INC.
MATERIAL HANDLING ENGINEERING
EST 1985
TEL (909)869-0989 FAX (909)869-0981
STRUCTURAL CORRECTION
FOR
RED DOT
2052 CORTE DEL NOG AL
CARLSBAD, CA
PLAN CHECK #03-3042
SEIZMIC, INC PROJECT* 03-1476
DATE • 12/04/03
BELOW ARE THE RESPONSES TO THE PLAN CORRECTION SHEET
(QUESTIONS 1-9 TO BE ADDRESSED BY OTHERS)
10 QUESTION Recheck all connections on sheet 03-1476A as follows a) The rivet bearing capacity is only dtFu = 406(0 747)65 =
2 kips b) Provide calculations for all beam to bracket weld capacities per section 2330 (allowable weld stress is the member thickness
times 26 ksi times 1 33, or the weld stress Whichever is lower) c) Check the bracket maximum weak axis moment
RESPONSE a) calculations for the rivet bearing capacity can be found on page 10 of the revised structural calculations the
column is 12 ga in thickness therefore the bearing capacity is dtFu = (4375 in) ( 105 in) (65 ksi) = 2 99 k b) calculations for the
beam bracket weld capacity is found on page 10A of revised structural calculations c) The maximum weak axis moment which the
bracket is subjected to is 49 Ib x 53 IN = 2597 IN-LB Which is less than moment capacity shown on page 10 for the bracket Please
see page 10 of revised calculations
11 QUESTION Provide calculations for the column weak axis bending plus axial for transverse seismic loading The axial load is
the maximum compression load at the base from vertical plus seismic overturning The column moment will probably be maximum
for the lateral load from the base plate to the first diagonal brace (not only to the first horizontal member)
RESPONSE Calculations for weak axis bending on the column can be found on page 8A of revised structural calculations
If there are any questions regarding this project please call me Thank you for your time and consideration
Sincerely ,
Roy J Farrow, Seizmic Inc
SEIZMIC
MATERIAL HANDLING ENGINEERING
EST 1985
STORAGE RACKS
DRIVE IN RACKS
CANTILEVER RACKS
MEZZANINES
CONVEYORS
CAROUSELS
STEEL SHELVING
MOVABLE SHELVING
STORAGE TANKS
MODULAR OFRCES
GONDOLAS
BOOKSTACKS
CITY APPROVALS
STATE APPROVALS
PERMITTING SERVICES
PRODUCT TESTING
FIELD INSPECTION
SPECIAL FABRICATION
ALASKA
ARIZONA
CALIFORNIA
COLORADO
IDAHO
MISSOURI
NEVADA
NEW MEXICO
CR33ON
PENNSYLVANIA
UTAH
WASHINGTON
SEISMIC ANALYSIS
OF STORAGE RACKS FOR
RED DOT
2052 CORTE DEL NOGAL
CARLSBAD CA
#03-1476
APPROVED BY
SAL E. FATEEN
1 2-04-2003
161 ATLANTIC STREET POMONA CA 91768 TEL (909)869-0989 FAX (909)869-0981
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO,OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_RF DATE.10-28-2003
TABLE OF CONTENTS
DESCRIPTION PAGE #
COVER SHEET 1
TABLE OF CONTENTS 2
SCOPE 2
PARAMETERS 3
CONFIGURATIONS 4
COMPONENTS & SPECS 5
LOADS AND DISTRIBUTION 6
LONGITUDINAL ANALYSIS 7
COLUMN 8
BEAM 9
BEAM TO COLUMN 10
BRACING 11
OVERTURNING 12
BASEPLATE 13
SLAB & SOIL 14
SCOPE
THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH
THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES
THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY,
WITHOUT ANY FIELD WELDING
SE1ZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO,OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_RF DATE.10-28-2003
MAHAMbIbHS
STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH
DIRECTIONS WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN
ANY ADJACENT BAYS
THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYZED IN BOTH
LONGITUDINAL AND TRANSVERSE DIRECTION
STABILITY LONGITUDINALLY IS DEPENDANT ON BEAM TO COLUMN MOMENT,
WHILE THE BRACING ACT TRANSVERSELY
1 COLUMN
2 BEAM
3 BEAM TO COLUMN
4 BASE PLATE
5 HORIZONTAL BRACING
6 DIAGONAL BRACING
7 BACK CONNECTOR
TRIBUTARY AREA
I
TRANSVERSE
I I
LONGITUDINAL
TOP VIEW
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF
OF_1 4
DATE.10-28-2003
CONFIGURATIONS
T39"
TYPE1
1,200 Ib
1,200 Ib
144"52"
1,200 Ib
44"
53"4"
96"t 42"-t. 42"-
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE.10-28-2003
TYPE1
SPECIFICATION
- MAIN STEEL 50000 PSI
- BASE PLATE STEEL 36000 PSI
- ANCHOR - WEDGE TYPE 1/2 x 2-1/4 IV
- FLOOR SLAB 4" X 2000 PSI REINFORCED 1 44" 52"
- SOIL BEARING PRESSURE 1000 PSF
-SEISMIC ZONE 4
- TYPE = INTERCONNECTED UNITS
1,200 Ib 134#171#
EMI
1
I2
t
!ED
44" £
•3
J
9"
2"
£
3"
3
1.200 Ib
2
1.200 Ib
1
p
>
98#
>
/
49#
4
C
4"
«
4"
4"
i
/
\
' A on
12——I
62
,
SECTION AXIAL FORCE MOMENT
lu = 96"
BEAM MOMENT
1 1,905 Ib 3,596 in Ib
2 1.270 Ib 3,023 in Ib
3 635 Ib 1,311 in Ib
4,509 in
3,367 in
1,856 in
Ib <-std conn
Ib <-std conn
Ib <-std conn
TYPE 1 DESIGN LOAD = 1200#
BASE PLATE
V
8 X 5 X 375
Mbase = 3595 in Ib
OVERTURNING
V
ANCHOR STRESS = 0 01
# OF ANCHORS = 2
V
COLUMN
COLUMN
3X3X12GA(LM30)
STRESS =0 20
BEAM
V
4-1/2X2-3/4X14GA(LBF454)
MAX LOAD/LEVEL = 5,071 Ib
BEAM IS O.K.
BRACING
HORIZONTAL V
11/2X1 1/4 X 14 GA
STRESS = 0 07
DIAGONAL V
11/2X1 1/4 X 14 GA
STRESS =017
SLAB & SOIL
V
PUNCT STRESS = 0 38
BENDING STRESS =0 31
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA91768
CALCULATED BY RF DATE 10-28-2003
LOADS & DISTRIBUTION: TYPE 1
LIVE LOAD PER SHELF (BASED ON CLIENT SUPPLIED DATA) =wLL
DEAD LOAD PER SHELF = wDL
SEISMIC BASE SHEAR DETERMINED IN ACCORDANCE WITH SECTION 1630 2 1 OF THE 2001 CBC = V
WHERE V = ((2 5 x Ca x I) / R) x Wtotal
Wtotal = (wLL/2 + wDL)
SEISMIC ZONE = 4
Ca = 0 44Na WHERE Ca = 0 44Na AND Na = 1
l= 1 00
SOILCOEF =Sd
R (LONGITUDINAL) = 56
R (TRANSVERSE) = 44
wDL = 70 LB
n=2
DEPTH= 42 in
LONGITUDINAL DIRECTION:
Vlong = [2 5*0 44*1*(3600/2+210)/5 6]/1 4
= 282 Ib
Fi = V Whi/IWh
TRANSVERSE DIRECTION
Vtrans = [2 5*0 44*1'(3600/2+210)/4 4J/1 4
= 359 Ib
Fi = V Whi/IWh
(SECTION 2228 5 2 )
(SECTION 2228 5 2 )
INTERCONNECTED UNITS
SEISMIC DISTRIBUTION
LEVEL h
IN
WEIGHT
LB
HEIGHT
IN
WXH
LB-IN
Fi (long)
LB
Fi (trans)
LB
Mot
IN-LB
1
2
3
530
520
390
1,200
1,200
1,200
530
1050
1440
63,600
126,000
172,800
495
981
1345
630
1248
171 1
3,338 5
13,1033
24,6448
144 IN 2= 362,400 282 LB 359 LB 41,087 IN-LB
TOTAL FRAME LOAD = 3810 LB
SEIZMIC PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO,7 OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE 10-28-2003
LONGITUDINAL ANALYSIS TYPE 1
THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE
COLUMNS ASSUMED AT MID-HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE
THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR
CLOSER TO THE BASE (OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT
CARRY MOMENT)
Vlong = 2 * Vcol
Vcol
F 1 = 25 Ib
F2= 49 Ib
F3= 67 Ib
282 Ib
141 Ib
Bc-am lo
Col Conn
Col in .sl
BASE PROVIDE PARTIAL FIXITY SEE BASE PLATE SHT
Mbase = 3595 in Ib
Mupper + Mlower = Mconn'R' + Mconn'L'
Mconn'R' = Mconn'L'
Mconn * 2 = Mupper + Mlower
Mconn = [Mupper + Mlower]/2
RESULTING FORCES ON COLUMN
SECTION AXIAL LOAD MOMENT Mconn
1 1905 3595 45092 1270 3022 33663 635 1311
Muppt,r
>-B—JlT SLAB
SEIZMIC
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.8
CALCULATED BY_RF
OF 1 4
DATE.10-28-2003
COLUMN ANALYSIS TYPE 1
COLUMN IS ANALYZED PER AISI COLD-FORMED STEEL DESIGN MANUAL
Pmax = 1,905 Ib Mmax = 3,596 in Ib
Kxlx/rx =12*51/13= 471 <-GOVERNS
Kyiy/ry = 8 * 44 / 1 079 = 326
Cc = (2;iA2E/Fy)A 5
= 1070
SINCE Kl/r <= Cc,
Fa = 522Fy - [(kl/r*Fy)/1494]A2
= 23,618 psi
fa = Pmax/Area
= 2,087 psi
fb = Mmax/Sx
= 3,491 psi
fa/Fa =009 <= 15
fa/Fa+fb/Fb <= 1 33
Fb = 6*Fy = 30,000 psi
fb/Fb = 0 12
COMBINED STRESS = 0 20
B
-I k-C
SECTION PROPERTIES
A = 3"
C = 75"
E = 0"
t1 = 1046"
B = 3"
D = 0"
Wt = 0#
t2 = 0"
Area = 913"A2
|X = 1 544"M ly = 1 064"A4
Sx = 1 03"A3 Sy = 68"A3
rx = 13" ry = 1 079"
52"
51"
44"
44"
4-
Front View
PROJECT
FOR
SHEET NO
RED DOT
CS GOODALE
8A OF 14
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE • POMONA, CA 91768
CALCULATED BY RF DATE 12-4-03
COLUMN ANALYSIS (3X3X1 2 GA) CROSS AISLE LOADS
ANALYZED PER DIV X, CHAP 22 OF THE 2001 CBC SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION
Pstatic- 1.905LB
Pseismic= 3596IN-LB/42 IN
= 86 LB
Ptotal= 1,991 LB
My= V*h
= 63 LB * 10 5 IN
= 662 IN-LB
KxLx/rx= 1 2*51 IN/1 3 IN
= 47 1 <=== (Kl/r)max
KyLy/ry = 0 8*44 IN/1 079 IN
= 32 6
AXIAL
Fe= TiA2E/(KL/r)maxA2
= 131 4KSI
Fy/2= 25 0 KSI
SINCE, Fe > Fy/2
THEN, Fn= Fy(1-Fy/4Fe)
= 50 KSI*[1-50 KSI/(4*131 4 KSI)]
= 45 2 KSI
Pn= Aeff*Fn
= 34,475 LB
Oc= 5/3 + (3/8)*R - (1/8)*RA3
= 1 82
Pa= Pn/Oc
= 34475 LB/1 81987678784367
= 1 8,943 LB
P/Pa= 011 < 0 15
FLEXURE
CHECK P/Pa + Mx/Max < 1 33
Pno= Ae*Fy
= 0 762 INA2 *50000 PSI
= 38,100 LB
Pao= Pno/Oc
= 38100 LB/1 81987678784367
= 20,935 LB
Myield=My= Sy*Fy
= 0 68 INA3 * 50000 PSI
= 51,500 IN-LB
Max= My/Df
= 51500 IN-LB/1 67
= 30,838 IN-LB
Pcr= nA2EI/(KL)maxA2
= nA2*29500 KSI/(1 2*51 IN)A2
= 120,023 LB
A—Pcol
SIDE ELEVATION
V= 63 LB
Mseismic= 3,596 Ih
h= 10 5 IN
DEPTH= 42 IN
I-LB
(EQ C4-3) SECTION PROPERTIES
A= 3 0 IN
B= 3 0 IN
(EQ C4-2) C= 0 75 IN
t= 0 105 IN
Aeff = 0 762 INA2
Ix = 1 544 INA4
(EQC4-1) Sx= 1 030INA3
rx = 1 300 IN
ly = 1 064 INA4
Sy = 0 680 INA3
ry = 1 079 IN
(EQ C5-3) Kx = 1 2
Lx= 51 OIN
Ky = 0 80
Ly = 44 0 IN
Fy= 50 KSI
E= 29,500 KSI
fif= 1 67
Cmx= 0 85
Cb= 1 0
/vx= {1/[1-(Oc*P/Pcr)]}A-i
= {1/[1-(1 81987678784367*1991 LB/1 20023 L
= 097
THUS,
(1991 LB/18943 LB) + (662 IN-LB/30838 IN-LB)012 < 1 33, OK (EQC5-3)
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.RF DATE 10-28-2003
BEAM ANALYSIS TYPE 1
BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACITY TO STABLIZE THE SYSTEM,
ALTHOUGH IT DOES NOT PROVIDE 100% FIXITY THUS, THE BEAMS WILL BE ANALYSED ASSUMING
THEY HAVE PINNED ENDS FOR THE COMPUTATION OF BEAM TO COL MOMENT CAPACITY, THE
PARTIAL FIXITY OF THE BEAM,(ASSUMED AT AN ARBITRARY 25% OF THE FIXED END MOMENT OR
2,000 in Ib WHICH EVER IS SMALLER) WILL BE ADDED
lact = 96 0 in
Imax = [1950 + 1200(M1/M2)]b/Fy
SINCE M1/M2 = 1 0
Imax = 3150*b/Fy = 173 in
SINCE Imax > lact Fb = 60Fy = 30,000 psi
MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON 4 5"
1) BENDING CAPACITY
M = Sx* Fb = wlA2/8
= 34230m Ib
CAPACITY = 2(8*M/I) = 5071lb
2) MAXIMUM ALLOWABLE DEFLECTION (L/180)
A = 5wlA4/384EI
CAPACITY = 2[(384EI)/(5*180*IA2)] = 7518lb
MAXIMUM STATIC LOAD PER LEVEL IS 5,071 Ib.
ALLOWABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL
Mstatic = wlA2/8 = LIVE LOAD*L/(2*8) Mallow(static) = Sx
Mimpact = 1 125*Mstatic Mallow(seismic) = 1 33 '
Mseismic = Mconn (SEE LONG ANALYSIS)
LEVEL Mstatic Mimpact Mallow Mseismic Mallow
1 125 Mstatic (Static) (seiSITlIC)
1 7200 8100 34229 4509 45639
2 7200 8100 34229 3366 45639
3 7200 8100 34229 1855 45639
Sx = 1 141 in "3
Ix = 2753 in A4
' Fb
Sx * Fb
1 5"
RESULT
GOOD
GOOD
GOOD
PROJECT.RED DOT
CSGOODALE
10 OF 1 4
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA91768
CALCULATED BY.DATF
BEAM TO COLUMN ANALYSIS:
CONNECTION CAPACITY DEPENDS ON THE FOLLOWING PARAMETERS
1) SHEAR CAPACITY OF STUDS
STUD DIAMETER= 7/16 IN
Fy= 55,000 PSI
Pmax-shear= 0 4 * Fy * Area
= 04* 55000 PSI * (0 4375 IN)*2 * rr/4
= 3,307 3 LB
2) BEARING CAPACITY ON COLUMN
Fu= 65,000 PSI
Pmax-brg= Bearing Area * Fbeanng
= (tmm * thickness) * (1 0 * Fu)
= (0 4375 IN * 0 105 IN) * (1 0 *65000 PSI)
= 2,985 9 LB < 3307 3 LB
3) MOMENT CAPACITY OF BRACKET
Mcap= Sbracket * Fbendmg
= 011 INA3 * 0 66 * Fy
= 3,993 IN-LB
C= Mcap/0 75 = 1 67 * P1
THUS, P1=0798*Mcap
= 3,186 IN-LB < 3307.3 LB
THUS, GOVERNING VALUE IS THE MIN VALUE OF PI ,
PI -eft- 2,986 LB
Mconn-allow= PI *4 5 IN + P2*2 5 IN + P3*0 5 IN
= 594*P1-eff * 1 33
= 23,649 IN-LB > Mconn max, OK
3-1 /4"
Mconn
S3
C
7
Mupper
rn
Is
Mlower
P2
Mconn
i"--V
2"
-1/2"
"l/2 "
C= PI + P2 + P3
= P1+P1*(2 5/4.5)+P1*(0 5/4 5)
= 1 67*P1
t=7 Sbracket= 0 110 IN A 3
JOvVN
1-5/8"
PROJECT
FOR
SHEET NO
RED DOT
CS GOODALE
10A 0F 14
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE • POMONA, CA 91 768
CALCULATED BY DATE 12-4-03
STEP BEAM WELD SECTION PROPERTIES & CAPACITIES
SCOPE:
DETERMINE THE EFFECTIVE SECTION PROPERTIES OF THE MEMBER WELD SHOWN
BELOW. THE EFFECT OF THE ROUNDED CORNERS ARE TAKEN INTO ACCOUNT
TYPE "A" WELD TYPE "B" WELD TYPE "C" WELD TYPE "D" WELD
BEAM & WELD INFO
A= 4 375 IN
B= 2 75 IN
C= 1 875 IN
D= 1 5 IN
t-weld* = 0 1 25 IN
Fu-weld= 70,000 PSI
Fy-base metal= 55,000 PSI
WELD TYPE
TYPE "A" WELD
WELD SECTION PROPERTIES
0.125 INCH THICK, TYPE "A" WELD
AREA=
Sx=
0 906 INA2
0 50 INA3
MOMENT CAPACITY=13,958 IN-LB
EFFECTIVE SECTION PROPERTY FOR WELD*
* TAKES INTO ACCOUNT 0 7071 REDUCTION FACTOR
— C —
1: ^
• B
— E —
y s s / .
:G
Ln^
D
F 1
1 Y-BJ
|
ELEMENT WIDTH HEIGHT Y-BAR ELEM AREA Y-BAR 1
1
2
3
4
5
6
0.0000 IN
01 250 IN
0.0000 IN
0 0000 IN
0.0000 IN
01 250 IN
0.0000 IN
4 3750 IN
0 0000 IN
0 0000 IN
0 0000 IN
2 8750 IN
0 0000 IN
2 1875 IN
0 0000 IN
0 0000 IN
0 0000 IN
1 4375 IN
ZAREA=
0 0000 INA2
0 5469 INA2
0 0000 INA2
0 0000 INA2
0 0000 INA2
0.3594 INA2 t
0.9063 INA2 "
y bar=
0 0000 INA4
0 9207 INA4
0 0000 INA4
0 0000 INA4
0 0000 INA4
0 321 2 INA4
WELD MOMENT CAPACITY UNDER SEISMIC LOADING
Fbase-metal= 0 6*Fy-base metal
= 33,000 PSI
Fweld= 0 3*Fu
= 21,000 PSI
Feffective= 21,000 PSI
CAPACITY= Feff * Sx-weld * 1.33
= 21000PSI*05INA3*1 33
=113.958 IN-LB I
1 890 IN
lx=1 .241 8 INA4
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO 11 OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY RF DATE.10-28-2003
TRANSVERSE ANALYSIS BRACING TYPE 1
IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND
COMPRESSION IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE
ON THE DIAGONAL MEMBER AS IT WILL GOVERN
DIAGONAL BRACING COMPRESSION MEMBER
Ldiag = [(L-6)A2+(D-2*Bcol)A2]A 5
= 523
Vdiag =Vtrans * Ldiag / D
= 447#
kl/rmm = [ 1 * 52 3 ] / 404
= 1295
Fa =[12;rA2E]/[23(kl/r)A2]
= 8895 psi
fa/Fa =Vdiag/(Area*Fa)
= 017
Dl= 52 3"
D= 42"
* 44"
DIAGONAL AND
HORIZONTAL BRACING
H
Area= 288 ""2
rmin= 404 "
t= 0747 "
W= 1 5 "
H= 1 25 "
f StIZMIC ^
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA91768
DqmFr.T RED DOT
mB CSGOODALE
12SHFFT NO '*•
pc
rAICIILATED BY ru
14
DATE 10-28-2003
OVERTURNING ANALYSIS: TYPE 1
ELn
ANALYSIS OF OVERTURNING WILL BE BASED ON SECTION
DEPTH = 42 in
TOP LEVEL HEIGHT = 144 in
FULLY LOADED
Total Shear= 359 Ib
Mot= I(Fi*hi)*1 15
= 47,250 m-lb
Mst = I(Wp+wDL)*D/2
= (3600lb + 210lb)*42in/2
= 80,01 Om-lb
Puplift = 1 (Mot - Mst)/Depth
= (47250-80010)742
= 0 Ib <= NO UPLIFT
TOP SHELF LOADED
SHEAR = 120 Ib EL 2
Mot = Vtop * ht
= 120 Ib* 144 in
= 17,229 m-lb
Mst = (Wp+wDL)*D/2
= (1200lb + 210lb)*42/2
= 29,610 in-lb
2228 7 1 OF THE 2001 CBC
EL 5 l_
EL 4
ELS
Puplrft= 1(Mot-Mst)/Depth
= 0lb
ANCHORS
QUANTITY= 2
PULLOUT = 773 LB
SHEAR= 1586LB
<= NO UPLIFT
<=== 33 1/3% INCREASE FOR SHORT TERM LOADING DUE TO SEISMIC FORCES
<=== 33 1/3% INCREASE FOR SHORT TERM LOADING DUE TO SEISMIC FORCES
Eq = (Ps/Pt)A5/3 + (Vs/Vt)A5/3 s 1 0
INTERACTION EQUATION
FULLY LOADED = (0 LB/1546 LB)A5/3 + (179 LB/3172 LB)A5/3
= 0 01 < 1 0 OK
TOP SHELF LOADED = (0 LB/1546 LB)A5/3 + (60 LB/3172 LB)A5/3
= 0 00 < 1 0 OK
USE (2) 1/2"0x2-1/4"MIN EMBED RAMSET/REDHEAD (I C B O #1372) OR APPROVED EQUAL
PULL OUT CAPACITY IS THAT OF WITHOUT SPECIAL INSPECTION
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.13 OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_RF DATE.10-28-2003
BASE PLATE TYPE 1
BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL
LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY)
THERE ARE 3 CRITERIA IN DETERMINING Mb THEY ARE 1) MOMENT CAPACITY OF THE BASE PLATE,
2) MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3) Vh/2 (FULL FIXITY) Mb IS THE SMALLEST
VALUE OBTAINED FROM THE 3 CRITERIA ABOVE
Pool = 1905 Ib
Mb= 3595 mlb
B = 8 in D = 5 in
b = 3 in
t = 375 in
b1 = 25 in
P/A = Pcol/(D*B) = 47 62 psi
M/S = Mb/((D*BA2)/6) = 6741 psi
fb2 = 2b/B*fb = 42 13 psi
fb1 = fb-fb2 - 25 28 psi
Mbase = wb1A2/2 = b1A2/2[ fa + fb1 + 67fb2]
Mbase = 315 6 in Ib
Sbase = 1*tA2/6 = 00234 in A3
Fbase = 75Fy * 1 33 = 36000 psi
fb/Fb = Mbase/(Sbase*Fbase) = 37
ANCHOR TENSION
T*d2=[Mbase- Pcol*b/2]
T = Mbase/d2 - Pcol*b/2d2
T = 164 Ib
Pcol
b
B
i i i t ' t •rm
fb I
fbl
Pcol
-*
d2
dl
dl
PROJECT.
FOR
RED DOT
CSGOODALE
SHEET NO.14 OF_1 4
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_RF DATE.10-28-2003
SLAB AND SOIL TYPE 1
THE SLAB IS CHECKED FOR PUNCTURE STRESS IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED TO
DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND HENCE, WILL ACT AS A FOOTING
(a) PUNCTURE
Pmax
Pmax
Fpunct = 2*sqrt(f'c)
Apunct = [(w+t/2)+(d+t/2)]*2*t
fv/Fv = Pmax/(Apunct*Fpunct)
1 4 DEAD LOAD + 1 7 LIVE LOAD
1 4 * Pool + 17* (Mot/d)
4,579 Ib
89 4 psi
1360 in A2 —
0 38
(b) SLAB TENSION
Asoil = Pmax/(1 33 * fsoil) = 3 43 ft A2
= 495 in A2
L = sqrt(Asoil) = 22 2 m
B = sqrt(w*d) + t = 10 3 in
b = (L-B)/2 = 6 0 in
Mconc = wbA2/2 = (1 33*fsoil*bA2)/(144*2)
= 1643 in Ib
Scone = 1*tA2/6 = 2 67 in A3
Fconc = 50 *sqrt(f'c) = 201 25 psi
fb/Fb = Mconc/(Sconc*Fconc) =031
BASE PLATE
w = 8 in
d = 5 in
CONCRETE
t = 4 in
fc = 2000 psi
SOIL
fs = 1000 psf
12/19/2803 08 59 7609315466 GOODALE PAGE 01/02
*ACORDr CE RTIFICATE OF LIABILITY INSURANCE
PRODUCER
Beacon Insurance Services, Inc.
442O Hot«l Ciz-ol* Ct., #3.70
Po Box 881188
San Diego CA 92168-1188
INSURED
C.S, Ooodale Company Inc.
6221 Yarrow Driva #B
Carlsbad CA 92009-
COVERAGES
DATE
03/10/2003
THIS CERTIFICATE 1$ ISSUED AS A MATTER OF INFORMATION
ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE
HOLDER THIS CERTIFICATE DOES NOT AMEND, EXTEND OR
. ALTE* THE COVERAGE AFFORDED BY THE POLICIES BELOW
INSURERS AFFORDING COVERAGE
INSURER A Unigard Insurance Company
INSURERS Harbor Specialty Insurance Company
INSURER C
INSURER D, _
INSURER E
THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWrTHSTANOINGAN f '
REQUIREMENT TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN
THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES
AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS
INSR
UB.
A
A
B
TYPE OF INSURANCE
Q5N6RAL LIABILITY
"" COVM5RCIAL OeNeRALLIABILITY
__J CLAIMS MADE H OCCUR
GEM. AOGREGATE LIMIT APPLIES PER
Tl POLICY! IJECT 1 lux
AUTOMOBILE LIABILITY
X ANY AUTO
ALL OWNED AUTOS
SCHEDULED AUTOS
X HIRED AUTOS
X NON-0WNEP AUTOS
GARAGE LIABILITY
ANY AUTO
excesa LIABILITY
~l OCCUR [ ^ CLAIMS MADE
____ DEDUCTIBLE
RETENTION *
WORKERS COMPENSATION ANDEMPLOYERS' LIABILITY
OTHER
POLICY NUMBER
CMOOS269
CM005269
HN30S734-01
POLICY EFFECTIVE
DATE(MWDOWY)
01/01/2003
01/01/2003
' /
, /
03/01/2003
POLICY EXPIRATION
01/01/2004
01/01/2004
/ /
1 '
1 1
1 I
01/01/2004
/ /
LIMITS
EACH OCCURRENCE
FIRE DAMAGE (Any wi« «re}
MED EXPfAny one person)
PERSONAL « AOV INJURY
GENERAL AGGREGATE
PRODUCTS - COMP/OP AOG
COMBINED SINGLE LIMIT
BOOILY INJURY
BODILY INJURY
(Psr ecciaenl)
PROPERTY DAMAGE
AUTO ONLY EA ACCIDENT
OTHER THAN EA ACC
AUTO ONLY . „„
EACH OCCURRENCE
A6GREOATE
X iTQ^YLJMrfsl I^R*
EL EACH ACCIDENT
61- OtSEASE - EA EMPLOYEE
E.L DISEASE. POLICY LIMIT
I 1,000,000
I 30,000
5,000
1,000,000
2,000,000
2,000,000
S 1,000,000
s
a
s
j
$
s
s
(
i
i
$
j 1,000,000
S 1,000,000
$ 1,000,000
DESCRIPTION OF OPERATIONS/LOCATIONS/V6HICLE6/EXCLUSION3 ADDED BY ENDORSEMENT/SPECIAL PROVISIONS
CERTIFICATE HOLDER >
-
ACORD 25-S (7/97)
t ADDITIONAL INSURED, INSURER LETTER _.. CANCELLATION
^ ~_ -
SHOULD ANY Qf THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE
EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL BNDSAVOR TO MAIL
3 0 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LSFT, BUT
FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY WHO UPON THE
INSURER. ITS AOENT3 OR REPRESENTATIVES
AUTHORIZE Q REPRM«S3-ATIVe J\
{' J/uf[/(/^f~ l]\ \j/)\Jis^-
® ACORD CORPORATION 1968
ELECTRONIC LASER FORMS INC (800)3270545
5 VOe So
- _• r-, °-:g._ D it-
>*• f i U- ^ - 'fa w o Q. 03
t
1
_L
3
4.
Srt J
^^V
i
T)
-4
^
t
o
-J
A Lbi
b
*M~> ^C*5.1 _^~
A
D
•o