HomeMy WebLinkAbout2055 BASSWOOD AVE; ; CBR2019-3126; PermitBuilding Permit Finaled Residential Permit Print Date: 10/30/2020 Job Address: 2055 BASSWOOD AVE, CARLSBAD, CA 92008-1111 Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: BLDG-Residential 2051603100 $7,441.60 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: O'MEARA: 160 SF REMODEL (KITCHEN) Applicant: ELENA OANTA 13786 PINE NEEDLES DR DEL MAR, CA 92014-3328 (858) 356-8398 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: OMEARA FRANCES 2055 BASSWOOD AVE CARLSBAD, CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Alteration Total Fees: $244.83 Total Payments To Date: $244.83 Ccityof Carlsbad Permit No: CBR2019-3126 Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Balance Due: Closed • Finaled 11/05/2019 01/03/2020 TAlva 10/30/2020 AMOUNT $97.22 $55.64 $41.00 $49.00 $1.00 $0.97 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760·602-8560 f I www.carlsbadca.gov (ci~of Carlsoad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Chec..Ctf<dD f{j • 3J,;1.{,, Est. Value Ji.Jf /lk, I() PC Deposit -------- Date I I-;i -19 • Job Address _'2_0_S_5_e,A..;;.__s_s-_w_o_oP_...;..t-:._v_e ___ ,Sulte: ___ APN: 205 -I 0o-3 \ . 00, CT/Project#:. _______________ lot#:. __ _ Fire Sprinklers: yes I@ Air Conditioning: yes {jjji> BRIEF DESCRIPTION OF WORK: \.G\"TC\-lcN R6)"\QD§..-- Electrical Panel Upgrade: yes @:> 0 Addition/New: _____ Uvlng SF, ___ Deck SF, ___ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ ;JiZI Remodel: Ji Q SF ofaffected area Is the area a conversion or change of use ? Yes@ 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? __________ _ O Solar: ___ KW, __ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: _______________________________ _ 0 Plumblna/Mechanical/Electrlcal Only: ______________________ _ lJ Other: ________________________________ _ APPLICANT (PRIMARY CONTACT) PROPERTY OWNER Name: !:cl.ENA OAN"IA Name: MP\P-1'.\.L..ElS 0 1 tv\~;b,RA Address: \37'p6 PINI> N1%-V&? ~-Address: 2055 J:<fl?SWGQ\:;, ~~ · City: !>£1-t:1AIZ. State:J;h_z1p: 0!2o\"r City: CAC VZ!2!'12 State: C/'<. Zip: C, '2.00 6 Phone: f2% 35h g;BB Phone:--'9'-"O"-''1..:..•...;4:....:4-'-'-I.:..• .::.5...;'l-:....:"i1'-'---~---- Emall:bomev\e~noo,l1£>rnq@ @rnoril.c.on, Email: A\,:".oWAtJ,._ ~ hotl')'\C\i I • C0/'11 DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: ~A OAN"iA Name: -----------------Address: \318& \"\~E N~l)\..!5, W., Address: _____________ _ City: P§..: Ml'<~ State:Q_z1p: GJZ.01-'t Cty: ______ State: __ Zlp: ____ _ Phone: 6® • ':)!Jf, -B'~~ Phone: ______________ _ Emall:bm,ede::ii_'}tl(Cdi.furni"-~9Q'.lc.\\lf.:0MEmall: _______________ _ Architect State License: C f ~ 9 23 State Ucense.: ______ Bus. License:. _____ _ (Sec. 7031.S Business c11nd Ptofessions Code. Any City or County which requires a permit to construct alter, Improve, demolish or repair 1ny structure, prior to Its Issuance, also requires the :.,pp,ieant for such permit to fiie a sisned statement that he/she ls licensed pul'$uant to the provisions of the Conttactor's License Law {Chapter 9, commending with Section 7000 of Olv,SiOn 3 of the Business and Professions Coda~ or that he/she Is exempt thMe'rom, and the basis for the alltged e)lemption. Any violation of Section 7031.S by any 111ppllcant for a permit subiects the ~kant to a ctvlt penalty of not m0te than flve hundred doHars ISSOO}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Buildlng@carlsbadca.gov B-1 Page 1 of2 Rev 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty a/ perjury l1£lt of the following declorotlons: □ I have and wll fflalntaln a certificate of consent to self-Insure for wo,kers' compe'IS8tlon provided bv Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will maintain wotket's compensateon, as required by Stctkln 3700 of the Labor Code, for the performance of the work fOI' whkh this permit Is ls.sued. My workers' compensation Insurance ca,f'it, atld policy mimberare: Insurance Company Name: __________________ _ Pollq,No. ____________ Explr■don 0-: ________ _ □ Certificate of Exemption. I certify that In thv performance of the WOrk for which this permit is issued, I shal not employ any person In any manner .so as to be come subject to the workers' compenHtiOn laws of California. WARNING: Falhltt to serure worktn compensation coverqe 11 unlawful, and 1h11 subject an employer to crlmlnll pen11tlts Ind clvlf flnH up to $100,000.00, In addition tfM to tht cost of compensation, d1ma1as as ptOVlded for In Setlion 3706 of the Labor Code, lnttrlst Ind attornev'• fees. CONTRACTOR SIGNATURE: ________________ □AGENT OAT£: ____ _ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's Lk:ense Law for the following reason: t1s owner oft~ propetty or my employees with wages es their sole compensation, will do the WOfk and the structure 1$ not Intended or offered for sale (Sec. 7044, Business and Profeulons Code: The Contractor's Ucense law does not apply to en owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provlded that such ·,.,..p,ovements a~ not intended or offered for sale. tf, however, the bulldin1 or Improvement ls sold within one year of completion, the owner-builder wlll have the burden of provlng that he d'd not bt1Ud or lmprove for the purpose of sale}. 'pJ. itS owner of the-property, am eicc.luslvely contracting with licemed contracto,s to construct the project (5ec. 7044, Businen artd ProfesslOns Code: The Contractor's License-Law does not apply to an owner of i:,roperty who bullds or Improves thereon, and contracts for such projects with contract.o,(s) licensed pursuant to the Contractor's License Law). 0 I am eJCempt under Section _______ Business ind Prof@sstons Code for this reason: 1.1 personally plan lo provide the major labor end materials for constructtOn of the proposed property improvement. r, Yes n No 2.1 {htnte / have not) signed an 1pp1icatlon for a bulldlng permit for the proposed work, 3, I have contracted wlth the followlng person (firm) to provide the proposed construction ltneiude name address/ phone/ contracto,s' license num~r): 4. I plan to prOYlde portions of the work. but I have hired the followlng person to cootd1nate, supervise and providit! the majOr wort (include name/ address/ phone/ contractors' :1cense number); 5. I wll provide some of the work, but I have contracted (hired) the following personJ to provide the work Indicated (include name/ address/ phone/ type or work): OWNER SIGNATURE: ?1'(a.,,A R«_ t?-~ □AGENT DATE: 11-'-1-1-, CONSTRUCTION LENDING AGENCY. IF ANY: I heteby affirm that there Is a construction lend Ins as ency for the i:,erformance of the work this.-permit Is issued {Sec. 3097 (i) Civil Code), Lender's Name:__________ _ _____ lander'sAddres1: _________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is tilt applicant or future bultdlns occupant required to submit a business plan, acutely h;uardous materlals feB!stration form or rtsk mana1ement and preventkm program under Sections 2550S, 2S533 or 25534 of I~ Presley, Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or fi.dUR! builldlns occupant required to obtain a permit from the air pollution control district or air quality management dlstrltt? 0 Yes □ No Is thefadflty to be constructed withki 1,000feet of the outer boundary of a school Site? n Yes □ No IF ANVOF THEANSWIASARE'V!S, A FtNAl CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APflllCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AJR POLLUTION CONTROL DISTRICT, APPLICANT CERTIFICATION: I certify that I have read the appicatlon and state thait the above Information IS correct and that the Information on the plans ls accurate. I asree to c.omply with all City ordinances and State laws relatlng to buHdlng construction, I her1by author!Je rep,esentattve of the Qty of Carlsbad to enter upon the abovementlOntd property for ,nspection purposes. I ALSO AGREE TOSAVE', INDEMNIFY ANO KEEP HARMI.E5S THE 0TY OFCARt.S8ADAGA1NST ALLLIABIUTIES, JUDGMENTS, COSTSANDEXPEN5E5 WHICH MAY IN ANY WAY ACCRUE AGAINST SAID OlY IN CONSEQUENCE Of THE GRANTING Of THISPERMIT.05Hk Ari OSHA permit Is required for excavattons om s•r, dnp and demolition or construction of structures cw, 3 stones In heisht EXf»tftATION· Every permit Issued bvthe Wld.ngOffldal under tht proYISionsof this Code shalle)(l)lre by Nmltatlon and become null and void If the bulldlng or work authorized by 5UCh permit Is not commencedwlthtn 180da\'5 from the date of such perml or If the building or work authorlmi by such permit 1S suspended or abandoned at ~time after the work ls commenc.d for a pe,tod d 180 dla"A~:tioo1,106A.4 Unlfoan BuffdinB; Code). APPLICANT SIGNATURE: __ 4-1,..,g,.::,t,4._,,..;;;_ _______ DATE:_....U ..... /f;__._}20 __ 11....._· - 1635 Faraday Ave Carlsbad, CA 92 S-1 h: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Emall: 8uilding@carlsbadca.gov Rev.06/18 Permit Type: Work Class: Status: Scheduled Date 10/30/2020 PERMIT INSPECTION HISTORY for (CBR2019-3126) BLDG-Residential Application Date: 11/05/2019 Owner: TRUST OMEARA FRANCES Alteration Issue Date: 01/03/2020 Subdivision: BELLEDONNA HEIGHTS UNIT# 1 Closed -Finaled Expiration Date: 01/25/2021 Address: 2055 BASSWOOD AVE IVR Number: 22887 CARLSBAD, CA 92008-1111 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency July 29, 2020: Yes 10/30/2020 BLDG-Final Inspection Checklist Item BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 1. Interior drywall nailing scope of work-approved. 142574-2020 COMMENTS Passed October 30, 2020: Tony Alvarado 1. Mechanical, electrical, plumbing, and structural final inspection-approved per plans and detail specifications. October 30, 2020: 1. Mechanical, electrical, plumbing, and structural final inspection-approved per plans and detail specifications. October 30, 2020: 1. Mechanical, electrical, plumbing, and structural final inspection-approved per plans and detail specifications. October 30, 2020: 1. Mechanical, electrical, plumbing, and structural final inspection-approved per plans and detail specifications. Complete Passed Yes Yes Yes Yes Friday, October 30, 2020 Pago 2 of 2 Building Permit Inspection History Finaled ('cityof Carlsbad Permit Type: Work Class: Status: Scheduled Date 07/14/2020 PERMIT INSPECTION HISTORY for (CBR2019-3126) BLDG-Residential Alteration Closed -Finaled Actual Inspection Type Start Date 07/14/2020 BLDG-11 Foundation/Fig/Piers (Rebar) Checklist Item Application Date: 11/05/2019 Issue Date: 01/03/2020 Expiration Date: 01/25/2021 IVR Number: 22887 Inspection No. Inspection Status 132930-2020 Partial Pass COMMENTS Owner: TRUST OMEARA FRANCES Subdivision: BELLEDONNA HEIGHTS UNIT# 1 Address: 2055 BASSWOOD AVE CARLSBAD, CA 92008-1111 Primary Inspector Reinspectlon Inspection Tony Alvarado Relnspectlon Incomplete Passed BLDG-Building Deficiency July 14, 2020: Yes 1. Foundation footing slab and 2' x 2' x 12" deep concrete pad -partial approval pending photo of 2' x 2' x 12" deep concrete pad contractor installed #3 rebar and engineer/architect requires to have #4 rebar's.-Per plan. 2. Contractor Sunny will provide picture of 2' x 2' x 12" deep.inches deep-concrete pad with #4 rebar's each way. 3. Rest of foundation/concrete slab reinforcement steel rebar scope of work-approved. 07/27/2020 07/27/2020 BLDG-84 Rough 133842-2020 Passed Tony Alvarado Incomplete Combo(14,24,34,44) Checklist Item BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers COMMENTS July 27, 2020: 1. Kitchen expansion/altered within existing dwelling footprint; framing, plumbing, electrical and mechanical rough inspection scope of work approved. July 27, 2020: 1. Kitchen expansion/altered within existing dwelling footpnnt; framing, plumbing, electrical and mechanical rough inspection scope of work approved. July 27, 2020: 1. Kitchen expansion/altered within existing dwelling footprint; framing, plumbing, electrical and mechanical rough inspection scope of work approved. July 27, 2020: 1. Kitchen expansion/altered within existing dwelling footprint framing, plumbing, electrical and mechanical rough inspection scope of work approved. 07/29/2020 07/29/2020 BLDG-17 Interior 134068-2020 Passed Tony Alvarado Leth/Drywall Friday, October 30, 2020 Passed Yes Yes Yes Yes Complete Page 1 of 2 DATE: 12-19-2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBR-2019-3126 ✓• EsG1I A SAFEbuilt Company SET: II PROJECT ADDRESS: 2055 Basswood Avenue PROJECT NAME: O'Meara Kitchen Remodel ~PLICANT / JURIS. C8] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: IJ.-/u?/tCi(byf;rVi\ Email: Mail Telephone Fax In Person 0 REMARKS: By: David Kniff, AIA EsGil 12-5-2019 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: 11-27-2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBR-2019-3126 ✓• EsG1I A SAFEbuitfCompany SET: I PROJECT ADDRESS: 2055 Basswood Avenue PROJECT NAME: O'Meara Kitchen Remodel □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gj The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gj The applicant's copy of the check list has been sent to: Elena Onata 0 EsGil staff did not advise the applicant that the plan check has been completed. [gj EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Elena Onata Telephone#: 858-356-8398 11e.-.coieltaete4;{.· .t:_· Z 11 L-{by:r-Q Email: homedesigncalifornia@gmail.com Telephone Fax In Person By: David Kniff AIA EsGil 11-7-2019 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (85 8) 560-1576 Carlsbad CBR-2019-3126 11-27-2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR-2019-3126 JURISDICTION: Carlsbad PROJECT ADDRESS: 2055 Basswood Avenue FLOOR AREA: 160 s.f. remodel REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 11-5-2019 DATE INITIAL PLAN REVIEW COMPLETED: 11-27-2019 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 11-7-2019 PLAN REVIEWER: David Kniff AIA This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list {or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR-2019-3126 11-27-2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: David Kniff AIA PLAN CHECK#.: CBR-2019-3126 DATE: 11-27-2019 BUILDING ADDRESS: 2055 Basswood Avenue BUILDING OCCUPANCY: R3 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Kitchen remodel 160 46.51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 uec Buildin Permit Fee g 1 .. ] t 997 UBC Plan Check Fee Type of Review: r Repetitive Fee I tfJ Repeats Comments: I" Complete Review r Other r Hourly EsGil Fee ,. Reg. Mod. VALUE ($) 7,442 7,442 r Structural Only $62.95) Sheet 1 of 1 Carlsbad CBR-2019-3126 11-27-2019 PLANS 1. Please make all corrections and submit two new complete sets of prints, to: The jurisdiction's building department. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). FIRE PROTECTION 3. Show locations of permanently wired smoke alarms with battery backup, per Section R314: a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story, including basements. d) Such smoke alarm locations shall comply with the following: i) They shall be not less than 3' from the door opening of a bathroom. ii) They shall be at least 20' from a cooking appliance. iii) They shall be at least 3' from supply registers of heating/cooling systems. iv) They shall be at least 3' from the tip of the blade of a ceiling- mounted fan. • NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 4. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.8.1. 5. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. b) On each story, including basements. Carlsbad CBR-2019-3126 11-27-2019 • NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 6. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. ELECTRICAL 7. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 8. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. 9. Per CEC Article 210.11 (C)1, note on the plans that there will be a minimum of 2 small appliance branch circuits within the locations specified in Article 210.52(6), i.e., kitchen and dining areas. PLUMBING 10. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411, 412. ENERGY CONSERVATION 11. All domestic hot water piping to have the following minimum insulation installed: ½" pipe (1/2" insulation);¾" pipe (1" insulation); 1" to 1-½" pipe (1-½" insulation). CPC 609.11 & ES 150.0(j) Carlsbad CBR-2019-3126 11-27-2019 Additionally, the ½" hot water pipe to the kitchen sink, and the cold water pipe within 5' of the water heater both require 1" minimum insulation. ES 150.O(j) Residential Energy Lighting Requirements: ES 150.0(k) · 12. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JAS-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 13. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Kniff AIA at EsGil. Thank you. C_ City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool ,. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ,. Details on CAP ordinance requirements are available on the city's website. ,. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: _\.::'._1_TC_I-\_E_:N_R_t:_M_O_p_E:-_l-______ BP No.: Cf>f2.'[l..6 (i', j (,2 "' PropertyAddress/APN: 2.0'5":5 t?f'07WOOJ) t,Vrc, ,CA\c-.L,5'~, CA Cfz.ooB/ 205 · \60-~\-oo Applicant Name/Co.: 8-c:N A OANTh Applicant Address: Contact Phone: Contact Email: Contact information of person completing this checklist (if different than above): Name: Company name/address: Contact Phone: Contact Email: Applicant Signature: --+-'_flV-<", ..,t,.. _1 _______ Date: __ \\~/_6_··_1_z_oi_oi_,_ c ~L/ / 8-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet:$ ,$, / JiD ./ {) I □ New construction □ Additions and alterations· )ff BPV < $60,000 ( □ BPV"' $60,000 □ Electrical service panel upgrade only □ BPV;, $200,000 □ New construction □ Alterations: □ BPV;, $200,000 or additions" 1,000 square feet □ BPV" $1,000,000 □ ;, 2,000 sq. ft. new roof addition Low-rise - N/A '\ -1A,4A 1A, 4A' Hlgh•rise 1 18, 28, : 38,4A - ,NIA j 4A 18, 4A' 1 B, 28, 38, 48 and 5 18, 5 18, 28, 5 28,5 . I( lllglklst residenflal buildlng is 4 or mMt stories, including a mlxed-\JSEI building in whiCh at least 20% of Its condilloned floor area is residential U68 All residential additions and alterations 1-2 family dwellings and townhouses with attached garages only 'Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed Building alterations of;, 75% existing gross floor area 1 B also applies if BPV;, $200,000 Please refer to Cansbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CAL Green) for more infomiation when completing this section. A. 0 Residential addition or alteration ~ $60,000 building permit valuation. □ NIA _________ _ See CMC section 18.30.190. D Exception: Home energy score ~ 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements D Before 1978 Select one: D Duct sealinQ D Attic insulation D Cool roof D Attic insulation D 1978 and later Select one: D Lighting package D Water heating Package D Between 1978 and 1991 Seect one: o Duct sealing D Attic insulation D Cool roof D 1992 and later Select one: D Lighting package D Water heating package B, 0 Nonresidential' new construction or alterations~ $200,000 building permit valuation, or additions~ 1,000 square feel D N/A Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency. AS.203.1.1 Choose one: □ .1 Outdoor lighting □ .2 Warehouse dock seal doors □ .3 Restaurant service water heating (comply ..;th California Energy Code section 140.5, as amended) □ N/A _________ _ □ .4 Daylight design PAFs □ .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: □ . 95 Energy budget □ .90 Energy budget □ N/A A5.211.1" D On-site renewable energy □ NIA A5.211.3" □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ N/A AS.212.1 □ Elevators and escalators □ N/A A5.213.1 □ Steel framing □ N/A 'lnciudes hotels/motels and hgh-rise residential buildings "For alterations" $1,000,000 BPV and affecting> 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltalc Systems A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) W projectincludes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise rasidential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc' sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1.15 x#d.u.) 'Fonmula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ D □ □ kWdc 8. D Nonresidential new construction or alterations ~$1,000,000 8PV and affecting ~75% existing floor area, or addition tihat increases roof area by ~2,000 square feet Please refer to CMC section 18.30.130 when completing tihis section. Note: This section also applies to high-rise residential and hoteUmotel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: □ If< 10,000s.f. Enter: 5 kWdc Min. System Size: □ If .e 10,000s.f. calculate: 15 kWdc x (GFN10,000) .. kWdc .. Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:~ ______ x .80= Min. system size: ____ _ kWdc mAttach calculation documentation using modeling software approved by the California Energy Commission. A. D Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. □ For systems serving individual dwelling units choose one: □ Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) □ Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) □ Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher □ Solar water heating system that is either .60 solar savings fraction or 40 s. f. solar collectors □ Exception: □ For systems serving multiple dwelling units, install a central water-heating system with all of the following: □ Gas or propane water heating system □ Recirculation system per CMC 18.30. 150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) □ Solar water heating system that is either: □ .20 solar savings fraction □ . 15 solar savings fraction, plus drain water heat recovery □ Exception: B. D Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. □ Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal □ Photovoltaics □ Recovered energy □ Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction □ Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electrlc Vehicle Charging A. D Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when completing this section. D One and two-family residential dwelling or townhouse with attached garage: D One EVSE Ready parking space required D Exception : D Multi-family residential· D Exception · Total Parking Spaces EVSE Spaces Proposed Can:able I Rearlv I I I Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearesl whole number) EVSE Installed= Total EVSE Spaces x .50 (rounded upto nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Installed I Total I 'Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation~ $200,000, intenor finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Readv I Installed I Total I I I Calculation· Refer to the table below· Total Number of Parking Soaces provided Number of recuired EV Spaces Number of recuired EVSE Installed Spaces D 0-9 1 1 D 10-25 2 1 D 26-50 4 2 D 51-75 6 3 D 76-100 9 5 D 101-150 12 6 D 151-200 17 9 D 201 and over 1 O oercent of total 50 oeroent of Required EV Soaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist .4,f':i~Deti'lalldMilnag4!fflent(TDM):Nonrell~IOIILY An approved Transportation Demand Management (TDM) Plan is required for all nonresidential projects that meet a threshold of employee-9enerated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your permit, staff will contact the applicant to develop a sire-specie TDM plan based on the permit details. Acknowledgment: Employee ADT Estimation for Various Commercial Uses Office (a/1)2 20 Restaurant 11 Retail, 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10th Edition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT , Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TDM plan and understand that an approved TDM plan is a condition of permit issuance. Applicant Signature: _________________ _ Date: ------ Pe/son other than Applicant to be contacted for TDM compliance (if applicable): Name(Pnnted): __________________ _ Phone Number: ____ _ Email Address: __________________ _ Updated 8/15/2019 6