HomeMy WebLinkAbout2055 CORTE DEL NOGAL; ; CB080879; Permit07-08-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB080879
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
2055 CORTE DEL NOGAL CBAD
Tl Sub Type
2130610800 Lot#
$93991600 Construction Type
Reference #
MC CONSULTANTS- 27,347 SF
OFFICE TO OFFICE
INDUST
0
5B
Applicant
S D C CORTE L L C
7065 EL CAJON BLVD
SAN DIEGO CA 92115
Status
Applied
Enterec1 By
Plan Approved
Issued
Inspect Area
Plan Check#
ISSUED
05/14/2008
RMA
07/08/2008
07/08/2008
Owner
S D C CORTE L L C
7065 EL CAJON BLVD
SAN DIEGO CA 92115
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$3,19425 Meter Size
$0 00 Add'l Reel Water Con Fee
$2 076 26 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$19738 PFF (3105540)
$0 00 PFF (4305540)
$000 License Tax (3104193)
$0 00 License Tax (4304193)
$000 Traffic Impact Fee (3105541)
$0 00 Traffic Impact Fee (4305541)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
HMP Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$433 00
$21000
$10650
$000
$000
$000
$000
77
$621739
Total Fees $6,21739 Total Payments To Date $6,21739 Balance Due $000
Ft IT ITT r>>T-\T/^ TUT A -V Tfl
IN STORAGE
ATTACHED
Inspector Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees 'exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other requireo information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will tw any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this propel NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations las previously otherwise expired
City of Carlsbad
1635 Faraday Ave Carlsbad CA 92008
760 602 2717 / 2718 / 2719
Fax 760-6028558
Building Permit Application
Plan Check No
Est Value
Plan Ck Dpos,t
SUITE#/SPACE#/UNIT#
CT/PROJECT#PHASE # # OF UNITS # BEDROOMS ((BATHROOMS TENANT BUSINESS NAME CONSTR TYPE I OCC GROUP
DESCRIPTION OF WORK Include Square Feet of Affected /Ueafs)
CITY STATE ZIP CITY STATE ZIP
PHONE FAX
EMAIL
03*..CONTRACTOR BUS NAME 3 C
ADDRESS ADDRESS
PITY STAT 71 P CITY STATE
CA
ZIP
PHONE FAX PHONE FAX
EMAIL EMAIL
ARCH/DESIGNER NAME & ADDRESS STATE LIC #STATE LIC #CLASS CITY BUS LIC #
(Sec 7031S Business and Professions Code Any City or County which requires a permit to construct, alter, improve demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he islicensed pursuant to the provisions of the Contractors License Law {Chapter 9 commending with Section 7000 of Division i of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation ofSection 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500})
Workers Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations
n I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued
I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers compensation, insurance carrier and policy
Policy No O&!.e'\3 AAO>^ G. _ Expirabon Date <T/ I^I f |fc- b / MO &MAJIT Ynumber are Insurance Co
This section need not be completed if the permit is for one hundred dollars ($100) or less
LTl Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of
California WARNING Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100 000) in
addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees
J&£ CONTRACTOR SIGNATURE <~'y(jU-~\}JL? --DATE
/ hereby affirm that I am exempt from Contractor s License Law for the following reason
O I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor's
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for
sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
D I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of
property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law)
D I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O Yes O No
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work)
ER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the
Presley Tanner Hazardous Substance Account Act' O Yes a No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' a Yes O No
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' a Yes O No
IF ANY OF THE ANSWERS ARE YES
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code)
Lender's Name Lender's Address
I hereby authorize representative of the City of Cartsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height '
EXPIRATION Every permit issued by the Building Official urafer the provisions ofthisCodeshallexpireby limitation and become null and void if the building or work authonzed by such pemnit is not commenced within
180 days from the date of such permit or if thebeildincjOr wdrk aulhonzed by suctvgarrnitjs suspended or abandoned at any tone after Ihe work is commenced for a penod of 180 days (Section 106 4 4 Unnpm Building Code)
^APPLICANT S SIGNATURE / ///^^^ yV/^V^^'-''^ DATE
City of Carlsbad
Final Building Inspection
Dept Building Engineering Planning CMWD
Plan Check #
Permit*
Project Name
Address
Contact Person
Sewer Dist
Inspected ,1
Bv Ul
Inspected
Bv
Inspected
Bv
Comments
CB080879
MC CONSULTANTS- 27 347 SF
OFFICE TO OFFICE
2055 CORTE DEL NOGAL
STEVE Phone 7605196801
CA Water Dist CA
-f~^ Date / /
"rT&iSl Inspected // /7^/^i
Date
Inspected
Date
Inspected
••
St Lite ^P""e,
Date
Permit Type
Sub Type
Lot 0
O Approved js^
Approved
Approved
* ii
12/01/2008
Tl
INDUST
Disapproved
Disapproved
Disapproved
Page 1 of 1
Christine Wauschek - MC Consultants Building
From "Michael Elliott" <mikeelhott2@cox net>
To "Pete Dreibelbis" <pdrei@ci carlsbad ca us>. "Michele Masterson"
<mmast@ci carlsbad ca us>, "Meghan Jacobson" <mjaco@ci carlsbad ca us>,
"Christine Wauschek" <cwaus@ci carlsbad ca us>, "Janean Hawney"
<Jhawn@ci carlsbad ca us>, <sean kabo@mcconsultants com>
Date 12/11/2008 1041 AM
Subject MC Consultants Building
Attachments 357 - MC Consulting Building - Insp2 doc
MC Consultants Building
Project Number PD 08-10
Drawing Number 461-3L
2055 Corte Del Nogal - CB080879
Landscape inspection comments are attached
Approved - Permit card was signed on December 11, 2008
file IIC \Documents and Settmgs\Cwaus\Local Settmgs\Temp\XPgrpwise\4940EE3FGW- 12/11 /2008
Inspection List
Permit# CB080879 Type Tl
Date Inspection Item
12/05/200889
12/05/200889
12/04/2008 89
12/04/2008 89
12/02/2008 89
12/02/2008 89
12/01/2008 89
12/01/200889
11/21/2008 19
11/21/2008 39
11/21/200839
11/20/200831
11/13/2008 11
11/13/200831
11/10/200834
10/31/2008 14
10/30/2008 14
10/28/2008 14
10/24/2008 14
10/16/200884
10/15/2008 84
09/23/2008 17
09/19/2008 14
09/17/2008 17
09/12/2008 14
09/12/2008 34
09/12/200844
09/11/200834
09/11/200844
09/10/200834
09/10/200844
09/08/2008 24
09/08/2008 34
09/03/2008 14
09/03/2008 17
09/02/2008 14
09/02/2008 17
08/29/2008 14
08/29/2008 34
08/27/2008 14
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Structural
Final Electrical
Final Electrical
Underground/Conduit-Wirm
Ftg/Foundation/Piers
Underground/Conduit-Wirm
Rough Electric
Frame/Steel/Bolting/Weldm
Frame/Steel/Boltmg/Weldin
Frame/Steel/Bolting/Weldm
Frame/Steel/Bolting/Weldm
Rough Combo
Rough Combo
Interior Lath/Drywall
Frame/Steel/Bolting/Weldm
Interior Lath/Drywall
Frame/Steel/Boltmg/Weldin
Rough Electric
Rough/Ducts/Dampers
Rough Electric
Rough/Ducts/Dampers
Rough Electric
Rough/Ducts/Dampers
Rough/Topout
Rough Electric
Frame/Steel/Bolting/Weldm
Interior Lath/Drywall
Frame/Steel/Bolting/Weldm
Interior Lath/Drywall
Frame/Steel/Bolting/Weldm
Rough Electric
Frame/Steel/Bolting/Weldm
INDUST
Inspector Act
JM
-
-
JM
-
JM
-
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
CO
Rl
Rl
CO
Rl
CA
Rl
CO
NR
NR
CO
AP
AP
PA
CO
AP
NR
AP
PA
PA
PA
AP
AP
AP
AP
AP
AP
CA
CA
CA
CA
AP
we
AP
AP
CA
CA
AP
AP
NR
MC CONSULTANTS- 27,347 SF
OFFICE TO OFFICE
Comments
NEED PLANNING OK TO OCCUPY BLDG
NEED PLANNING/LIST
SHAWN
p m please
NEED ALL DEPARTMENTS
LIGHT POLES
LIGHT POLE FTGS
1ST FLR T-BAR COMPLETE
1STFLRT-BAR
2ND FLR T-BAR COMPLETE 1ST FLR
HALLWAYS
2ND FLR T-BAR
1ST FLR GRID OK TO SET PERMITER
NEED FIRE AP
2ND FLR T-BAR PERIMETER AND
INTERIOR OFFICES ONLY OK TO SET
PERIMETER TILE
BATHROOMS & LOCKER ROOMS
WOOD STAIRS
1ST FLR HARD LIDS
1ST FLR HARD LIDS & STAIR FRAME
HARD LIDS & 1ST & 2ND FLR
BATHROOMS
STEVE
STEVEN
MENS & WOMENS 1ST & 2ND FLR
ENTRY / LOBBY
2ND FLR SOFFITS
STEVE
2ND FLR SOFFITS
2ND FLR SOFFITS
Friday December 05 2008 Page 1 of 2
08/27/2008 24 Rough/Topout JM AP
08/25/200817 Interior Lath/Drywall JM AP
08/21/2008 14 Frame/Steel/Bolting/Weldm JM CO
08/20/2008 14 Frame/Steel/Bolting/Weldm JM AP
08/20/2008 34 Rough Electric JM AP
08/14/200817 Interior Lath/Drywall JM AP
08/05/2008 14 Frame/Steel/Bolting/Weldm JM AP
08/05/2008 31 Underground/Conduit-Wirm JM AP
08/05/2008 34 Rough Electric JM AP
07/31/200811 Ftg/Foundation/Piers TP AP
07/31/200812 Steel/Bond Beam TP AP
07/28/2008 14 Frame/Steel/Bolting/Weldm PY PA
07/28/200821 Underground/Under Floor PC AP
07/28/200824 Rough/Topout PY AP
07/21/200811 Ftg/Foundation/Piers JM AP
07/18/200811 Ftg/Foundation/Piers JM CO
07/15/200811 Ftg/Foundation/Piers JM CO
07/11/200814 Frame/Steel/Bolting/Weldm JM CO
2ND FLR MENS & WOMENS LOCKER
ROOM & KITCHEN
1ST FLR OFFICES WALLS ONLY
COMPLETE HVAC @ HARD LIDS
1ST FLR WALLS OFFICES ONLY
1ST FLR WALLS OFFICES ONLY
2ND FLR OFFICES WALLS ONLY
2ND FLR WALLS ONLY
1ST FLR FLOOR BOXES
2ND FLR WALLS
2 STAIR LANDING FTGS
2 CLMN BASE FTGS
1ST FLR
(3) POST FTGS
SAME
INSTALL MAT PADS AND SET AB
TEMPLATE
plum undergr required
Friday December 05 2008 Page 2 of 2
City of Carlsbad Bldg Inspection Request
For 12/15/2008
Permit* CB080879
Title MC CONSULTANTS- 27,347 SF
Description OFFICE TO OFFICE
Inspector Assignment JM
2055 CORTE DEL NOGAL
Lot 0
Type Tl Sub Type INDUST
Job Address
Suite
Location
ONTRACTOR MC3 CONSTULTANTS, INC
Owner S D C CORTE L L C
Remarks
Phone 7605196801
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By SHAWN
Entered By CHRISTINE
Act Comments
£1
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
PCR08076 ISSUED MC CONSULTANTS STRUCTURAL CHANGES ROOF HATCH RELOCATED
PCR08119 ISSUED MC CONSULTANTS REVISIONS
PCR08126 ISSUED MC CONSULTANTS ELECTRICAL REVISIONS
Inspection History
Date Description Act Insp
12/05/2008 89 Final Combo CO JM
12/04/2008 89 Final Combo CO JM
12/02/2008 89 Final Combo CA JM
12/01/2008 89 Final Combo CO JM
11/21/2008 19 Final Structural NR JM
11/21/2008 39 Final Electrical CO JM
11/21/2008 39 Final Electrical NR JM
11/20/2008 31 Underground/Conduit Wiring AP JM
11/13/2008 11 Ftg/Foundation/Piers AP JM
11/13/2008 31 Underground/Conduit-Wiring PA JM
11/10/2008 34 Rough Electric CO JM
Comments
NEED PLANNING OK TO OCCUPY BLDG
NEED PLANNING/LIST
SHAWN
NEED ALL DEPARTMENTS
LIGHT POLES
LIGHT POLE FTGS
City of Carlsbad Bldg Inspection Request
For 12/05/2008
Permit* CB080879
Title MC CONSULTANTS- 27,347 SF
Description OFFICE TO OFFICE
Inspector Assignment JM
2055 CORTE DEL NOGAL
Lot 0
Type Tl
Job Address
Suite
Location
ONTRACTOR MC3 CONSTULTANTS, INC
Owner FILSINGER STEVE C
Remarks
Sub Type INDUST
Phone 7605196801
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By SHAWN
Entered By CHRISTINE
f i/
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
PCR0807y ISSUED MC CONSULTANTS STRUCTURAL CHANGES ROOF HATCH RELOCATED
PCR08119VHS8UED MC CONSULTANTS REVISIONS
PCR08126VfSSUED MC CONSULTANTS ELECTRICAL REVISIONS
Inspection History
Date Description Act Insp
12/04/2008 89 Final Combo CO JM
12/02/2008 89 Final Combo CA JM
12/01/2008 89 Final Combo CO JM
11/21/2008 19 Final Structural NR JM
11/21/2008 39 Final Electrical CO JM
11/21/2008 39 Final Electrical NR JM
11/20/2008 31 Underground/Conduit-Wiring AP JM
11/13/2008 11 Ftg/Foundation/Piers AP JM
11/13/2008 31 Underground/Conduit Wiring PA JM
11/10/2008 34 Rough Electric CO JM
10/31/2008 14 Frame/Steel/Bolting/Weldmg AP JM
Comments
NEED PLANNING/LIST
SHAWN
NEED ALL DEPARTMENTS
LIGHT POLES
LIGHT POLE FTGS
1ST FLR T BAR COMPLETE
City of Carlsbad Bldg Inspection Request
For 09/08/2008
Permit* CB080879
Title MC CONSULTANTS- 27,347 SF
Description OFFICE TO OFFICE
Inspector Assignment JM
2055 CORTE DEL NOGAL
Lot 0
Type Tl Sub Type INDUST
Job Address
Suite
Location
OWNER S D C CORTE L L C
Owner FILSINGER STEVE C
Remarks 1pm or so please
Phone 7605196801
Inspector
Total Time Requested By STEVE
Entered By KATHY
CD Description
24 Rough/Topout
34 Rough Electric
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs
PCR08076 ISSUED MC CONSULTANTS
Inspection History
Original PC#
STRUCTURAL CHANGES ROOF HATCH RELOCATED
Date
09/03/2008
09/03/2008
09/02/2008
09/02/2008
08/29/2008
08/29/2008
08/27/2008
08/27/2008
08/25/2008
08/21/2008
08/20/2008
08/20/2008
08/14/2008
08/05/2008
08/05/2008
08/05/2008
07/31/2008
Description
14 Frame/Steel/Bolting/Welding
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
34 Rough Electric
14 Frame/Steel/Bolting/Welding
24 Rough/Topout
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
14 Frame/Steel/Bolting/Weldmg
34 Rough Electric
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Weldmg
31 Underground/Conduit Wiring
34 Rough Electric
1 1 Ftg/Foundation/Piers
Act
AP
AP
CA
CA
AP
AP
NR
AP
AP
CO
AP
AP
AP
AP
AP
AP
AP
Insp
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
JM
TP
Comments
ENTRY / LOBBY
2ND FLR SOFFITS
STEVE
2ND FLR SOFFITS
2ND FLR MENS & WOMENS LOCKER ROOM & KITCHEN
1ST FLR OFFICES WALLS ONLY
COMPLETE HVAC @ HARD LIDS
1 ST FLR WALLS OFFICES ONLY
2ND FLR OFFICES WALLS ONLY
2ND FLR WALLS ONLY
1ST FLR FLOOR BOXES
2ND FLR WALLS
2 STAIR LANDING FTGS
HE CITY OF DIEGO
'IVi'vON OF J jILDIV^ j, A.-=~v
NJPECTIONSl-.Rv'lCLS
.el iBi'S) 1 J2 jO/"Fi'.in-,S)4t'2 iUJB
SPECIAL INSPECTOR ID CARD
........... ROGER.-.EHLE
tsod Decembers! 2010
:.r.E REVEflSE SIDE f:OK 1 1 PEIS} OF WORK AUTHORIZED fr-OK
Roger R Ehlers
n i'.ii. _ i i->!or Jihn;l
05101131 _
i i I .1 mil
October 1 2011
I X.IIMI I Oil,.
VU I i.)l\!i l\SPl-0''OR
Roger R. Ehlers
Hi o ii'ihu! > !lit .. i; ii r _l <it li-ii"!! ii I i I ihi ^ViS S; ii I i I »
0 C i ii
\
' VI. ll ,. ll |1. li I '.)( ! .»,
» 111 ._ 1 i HI! ... '* vi )|'K !l HI . I Ok f bllJlJ
t UM oi^ %! in;-, i
October 2008
ROGER EHLERS
STRUCTURAL WELDiNG SPECIAL INSPECTOR
written examination
Expiration date
No 5315980 S2 ___
x ^^ holder
,CC ce^caton attests fo compete,/ toowtedge of codes and standards
Warren W. Scott + Architecture
Project Clarifications and Substitutions
Clarification 2
August 15, 2008
Project MC2 Consultants Tl, 2055 Corte Del Nogal, Carlsbad
Contractor MC3 Consultants
Clarifications and Substitutions to plans:
The following clarifications and modifications shall be noted to the construction documents
1 The following partial framing plan, detail sketch and calculation are provided to indicate the
cutting of the top cord of an existing floor truss to accommodate the installation of a toilet
flange where required The extent of the cut in the top cord shall be limited to a max of 4-
1/2" Plywood shall be placed each side of truss and shall extend two bays of the truss
framing in the location of the notch In addition, a 6' long x 1 -3/4"x 5-1/2" L VL shall be
applied to one side of the truss, centered on notch with attachment as per detail
Warren W Scott, Architecture
Warren W Scott
C11211
763 2nd Street • Suite 200 • Encinitas • California • 92024 • 760 943 8180 • FAX 760 943 0119
CONG PAD FTG SCHEDULE
P1 -36"SQ x12"THK PAD
FTG W/ (4) #4 EA WAY
P2-48"SQ x12"THK PAD
sFTG W/ (5) #4 EA WAY
Truss notched for
toilet plumbing, See
attached detail
NEWS
SQ x 1/4"
STL COL;
Notch Existing
Floor Truss
NEW FLOOR
INFILL WITH 11 9"
EXIST DBL 2x4 TOP CHORD CUT
AS REQUIRED
EXIST STL TUBE DIA, CUT
AS REQ'D
EXIST UJEB VERTICAL
CUT AS REQUIRED
NEW
P-TRAP
2/B' PLYUJD EA. SIDE
W 8d « fe1 OjC EDGE
NAIL AND ed « 12'
OjC FIELD NAIL
6>'-0' LONG 1-3/41 X 5-1/2'
LVL UJ/ 1/4-X4-W
SIMPSON SDS SCREWS AT
4'oc. STAGGERED AT ONE
SIDE OF NOTCH
X X X X. X AX V X«l
v\\H\X\XV^CJi \ /1 /y\ / / i
NEW TOILET FLANGE
AND P-TRAP CUT INTO
TOP CORD OF TRUSS,
VERIFY LOCATION
NOTCH PLYWD ON ONE
SIDE TO CONNECT TRAP
TO UJASTE PIPING
v/vv yyTT"
X XAXX VXiX^X \ '
V
/ / / / \ /
NOTCH FOR P-TTRAP SHALL BE
LOCATED WITHIN THIS AREA
PLYWOOD FOR1 TUIO (2) BAYS
EXIST DBL'2x4 BOTTOM CHORD
fe'-0' LONG X 1-3/4' X 5-1/21 LVL
CENTERED ON NOTCH AT ONE SIDE
NOTCH IN EXISTING TRUSS Revlftsd &-I&-
WARREN W SCOTT
C-011211
Palos Verdes Engineering Corporation
Consulting Structural Engineers
6027-1 Paseo Delicias • P O Box 2211 « Rancho barvto Fe CA 92067
Telephone (858) 759-2434 • Tax (858) 759-S324
JOB
OF iSI1LCT NO jl
CALCULATED BY PS.
CHECKFD BY DATE
SOIbd 8b
20Q8-D£C-Q3 03 50PM FROM-
£& 7575 METROPOLITAN DRIVE SUITE 203
1 SAN DIEGO CA 92108
RETURN SERVICE REQUESTED
CONVEYANCE PERMIT
T-410 P 001/00! F-618I r\ t «- s-* ~ _
DEPARTMENT OF INDUSTRIAL RELATIONS
DIVISION OF OCCUPATIONAL SAFETY AND HEALTH
PERMIT TO OPERATE A CONVEYANCE
***""• "•***AinO<""^ D1GI1 921 40 7<1MADISON SQUARE PROP MGMT
ATfN LlSABOSS'lICK PROPMGR
5414 OBERLIN DR STC 140
SAN DIEGO, CA 92121-4744
Conveyance Number J 42669 Permit Expires 08/04/2009
Inspection Date
Issue Date
08/04/2008
11/25/2008
Location 2055 COR TE DEL NOGAL
CARLSBAD CA
92009
Owners ID P4SS1
California law requires that all conveyances shall have a valid permit posted conspicuously
on the conveyance (Labor Code Sections 7300-7324) Please detach your new permit at the
dotted line and post on the conveyance Retain this portion for your records
STATE OF CALIFORNIA
Department of Industrial Relations
Division of Occupational Safety & Health
INSPECTION 142669
Conveyance Number
LOCATION 5055 CORTE DEL NOGAL
Street Address
08/04/2008 08/04/2009
Date of Inspection Date Permit Expires
CARLSBAD
City or Town
LOAD PERMISSIBLE 002500
Pounds
076
Persons
H3636
Inspector
DESCRIPTION PASSENGER
Type af Conveyance
EV02
PASS 1
Owner s Id
HYDROELECTRIC
Power
HYDROELECTRIC
Type of Machina
THIS PERMIT SHALL BE POSTED ON THE CONVEYANCE
EsGii Corporation
In Partnership witfi. government for (BuiCding Safety
DATE June 30, 2OO8
JURISDICTION Carlsbad OPLAN REVIEWER
a FILE
PLAN CHECK NO O80879 SET HI
PROJECT ADDRESS 2055 Corte Del Nogal
PROJECT NAME Office T I for MC Consultants, Inc
AJ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Abe Dohente Enclosures
Esgil Corporation
D GA D MB D EJ D PC 6/27/08
9320 Chesapeake Drive, Suite 20S + San Diego, California 92123 * (858)560-1468 4 Fax (858) 560 1576
EsGil Corporation
In (Partnership with government for (Building Safety
DATE June 19, 2008
JURISDICTION Carlsbad
PLAN CHECK NO 080879 SET II
PROJECT ADDRESS 2055 Corte Del Nogal
PROJECT NAME Office T I for MC Consultants, Inc
APPLICANT
PLAN REVIEWER
a FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X3 The applicant's copy of the check list has been sent to
Warren W Scott
987 Hermes Ave , Encmitas, CA 92024
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Warren W Scott Telephone # 760/943-8180
Date contacted 6//?//i?/fby-^fej Fax # -0119
Mail * Telephone Fax^X In Person
REMARKS
By Abe Dohente Enclosures
Esgil Corporation
S GA D MB D EJ D PC 6/11/08
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 *• Fax (858) 560-1576
Carlsbad O8O879
June 19, 2OO8
RECHECK CORRECTION LIST
JURISDICTION Carlsbad PLAN CHECK NO O8O879
PROJECT ADDRESS 2055 Corte Del Nogal SET II
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED
ESGIL CORPORATION 6/11/08 June 19, 2O08
REVIEWED BY Abe Doliente
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Building Code,
Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy
conservation, noise attenuation and disabled access This plan review is based on regulations
enforced by the Building Department You may have other corrections based on laws and
ordinances enforced by the Planning Department, Engineering Department or other
departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations The approval of
the plans does not permit the violation of any state, county or city law
A Please make all corrections on the original tracings and submit three new complete sets of
prints to Esgil Corp ortothebldg dept of the juris
B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections Please contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
QYes UNo
Carlsbad O8O879
June 19, 2008
Please make all corrections, as requested in the correction list Submit three new
complete sets of plans for commercial/industrial projects For expeditious processing,
corrected sets can be submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
1 Plans and calculations shall be signed by the California state licensed engineer or
architect where there are structural changes to existing buildings or structural additions
Please include the California license number, seal, date of license expiration and date
plans are signed California Business and Professions Code
PLUMBING AND MECHANICAL CORRECTIONS
PLAN REVIEWER Glen Adamek
GENERAL AND ARCHITECTURAL PME ITEMS
1 The final set of corrected drawings to be reviewed for signing and sealing just
before the permits are to be issued Each sheet of the plans must be signed by the
person responsible for their preparation, even though there are no structural changes,
before the permits are issued Business and Professions Code
2 The response by Warren W Scott, the Architect "See Attached" and the response
by DEC Engineers "See Architectural responses for 1 through 4 comments " No
response provided Correct the new Storage Rooms over 100 square foot in area to
show the required separation As per IBC, table 508 2 the incidental use areas for
storage rooms over 100 sq ft of floor area, shall be separated from the remainder of the
building by a fire barrier or if provided with an automatic fire extinguishing system the
separation must comply with IBC, Section 508 2 2 "the incidental use area shall be
separated form the remainder of the building by construction capable of resisting the
passage of smoke The partitions shall extend from the floor to the underside of the fire-
resistance-rated floor/ceiling assembly or fire-resistance-rated roof/ceiling assembly
above or to the underside of the floor or roof sheathing, or sub deck above Doors shall
be self- or automatic closing upon detection of smoke in accordance with Section
715473 Doors shall not have air transfer openings and shall not be undercut in excess
of the clearance permitted in accordance with NFPA 80 "
Carlsbad 080879
June 19, 2008
3 The response by Warren W Scott, the Architect "See Attached" and the response
by DEC Engineers "See Architectural responses for 1 through 4 comments " No
response provided Include, on the mechanical plans, the locations of all required
smoke, fire, combination smoke and fire, or ceiling radiation dampers Be sure to include
a symbol on the symbol schedule for each damper type IBC 716
4 The response by Warren W Scott, the Architect "See Attached" and the response
by DEC Engineers "See Architectural responses for 1 through 4 comments " No
response provided Please correct the drawings to show the required "Guards" (guard
rails) as per IBC, Section 1013 5 "Where appliances, equipment, fans, roof hatch
openings or other components that require service are located within 10 feet of a roof
edge or open side of a walking surface "
PLUMBING (2006 UNIFORM PLUMBING CODE)
6 The sheet P1 0 does not show the mam water line from the water meter to the
building And sheet P2 1 still shows an existing 11/2 inch water main serving this
building Please correct The existing 11/2 inch water mam serving this building, as
shown on sheet P2 1, seems to be undersized for the total building water demand as per
the water line sizing calculations on sheet PO 2 Please correct the water line sizing from
the public water meter to the new fixtures
9 Please provide cut-sheets and installation instructions for the proposed
Thermostatic Mixing Valve, including instructions for installing on a hot water
recirculation system Without special controls the hot water pump can force the
water temperature above the set temperature limit Please address Hot water
supplied to a public use lavatory or any bathtub is limited to a maximum temperature
potential of 120 degrees Detail how this temperature limitation is achieved Note The
water heater thermostat may not be used for compliance with this Code section UPC
4131 & UPC 414
10 The response by Warren W Scott, the Architect "See Attached" and the response
by DEC Engineers "See Architectural responses for 1 through 4 comments " No
response provided Floors shall slope to the floor dram(s) location(s) Please detail on
the architectural floor plans UPC 411 4
MECHANICAL (2006 UNIFORM MECHANICAL CODE)
16 The plans show new exhaust fan from the elevator equipment room, with no make-
up air Also, the elevator equipment room must be one hour fire rated separated
from the rest of the building Detail make-up air and required smoke and fire
dampers Provide the exhaust and make-up air design for the occupancy type listed in
Table 4 4 UMC 403 7
Note If you have any questions regarding this Plumbing and Mechanical plan review list please
contact Glen Adamek at (858) 560-1468 To speed the review process, note on this list (or a
copy) where the corrected items have been addressed on the plans
EsGii Corporation
In (Partnership wild government for (BuiCding Safety
DATE May 23, 2O08 a APPLICANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 080879 SET I
PROJECT ADDRESS 2055 Corte Del Nogal
PROJECT NAME Office T. I for MC Consultants, Inc
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
2<] The applicant's copy of the check list has been sent to
Warren W Scott
987 Hermes Ave , Encmitas, CA 92024
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Warren W Scott Telephone # 760/943-8180
Date contacted S/2=>'c& (by ^ ) Fax # - 0119
Mail / Telephone Fax"/ In Person
REMARKS
By Abe Dohente Enclosures
Esgil Corporation
$3 GA ER] MB D EJ D PC 5/15/08
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576
Carlsbad O80879
May 23, 2OO8
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO O80879
OCCUPANCY B
TYPE OF CONSTRUCTION V-B
ALLOWABLE FLOOR AREA exist'g
SPRINKLERS'? Yes
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED May 23, 2008
JURISDICTION Carlsbad
USE Offices
ACTUAL AREA 27,347 SF
STORIES 2
HEIGHT
OCCUPANT LOAD 273
DATE PLANS RECEIVED BY
ESGIL CORPORATION 5/15/08
PLAN REVIEWER Abe Dohente
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled This plan
review is based on regulations enforced by the Building Department You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments Clearance from those departments may be
required prior to the issuance of a building permit
Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of
the 2006 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans
Carlsbad O80879
May 23, 2008
Please make all corrections, as requested in the correction list Submit three new
complete sets of plans for commercial/industrial projects For expeditious
processing, corrected sets can be submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
• PLANS
1 Plans and calculations shall be signed by the California state licensed engineer
or architect where there are structural changes to existing buildings or structural
additions Please include the California license number, seal, date of license
expiration and date plans are signed California Business and Professions
Code
2 Provide a Building Code Data Legend on the Title Sheet Include the following
code information for each building proposed
* Occupancy Classification(s) B
* For Mixed Occupancy Buildings, state whether the "nonseparated" or
"separated" option was chosen from Section 508 3
* Description of Use Offices
* Type of Construction V-B
* Sprinklers Yes
* Stories 2
* Height
* Floor Area 27,347 SF
* Occupant Load 273
• EXIT SIGNS
3 Exit signs are required whenever two exits are required Show all required exit
sign locations Section 1011 1
4 A tactile sign stating "EXIT" and complying with ICC A117 1 shall be provided
adjacent to each door to an egress stairway, an exit passageway and the exit
discharge Section 1011 3
Carlsbad O8O879
May 23, 2008
5 Show two sources of power for the lamps at exit signs Section 1011 53
6 Show that the means of egress path will be lighted with at least one foot candle
at floor level Section 1006
7 Show separate sources of power may be required for exit illumination Review
Section 1006 3
• ACCESSIBILITY
8 Compliance with the disabled access requirements are either shown on noted on
the plans These will have to be field verified
• ADDITIONAL
9 Recheck the call-outs and cross referencing of the details Refer to sheets A3 4,
A4 2 and S2 2 of the plans
10 Please see the following corrections for electrical, energy, plumbing and
mechanical
11 To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet, note or detail number,
calculation page, etc
12 Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly
describe them and where they are located in the plans
Have changes been made to the plans not resulting from this correction
list7 Please indicate
Q Yes a No
13 The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Abe Dohente at
Esgil Corporation Thank you
Carlsbad O80879
May 23, 2OO8
* ELECTRICAL & ENERGY PLAN REVIEW
* 2005 NEC
• PLAN REVIEWER Morteza Beheshti
1 All electrical sheets of the plans are required to be signed by the California
licensed engineer responsible for the plan preparation Please include the
California license number, seal, date of license expiration and the date the plans
are signed Business and Professions Code (final set)
2 Show on the plan the location of the service(s) NEC 110 26, 230 2
3 Some areas such as the training room on the second floor do not have
emergency illumination at the floor level Please specify a second source of
power for the emergency lights IBC 1006, NEC 700 16
4 If utilizing a series-rated system, note on plans "Overcurrent device enclosures
will be identified as series-rated and labeled in accordance with NEC 110-22"
and" The overcurrent devices shall be AIC rated per manufacturers labeling of
the electrical equipment"
• ENERGY CONSERVATION
5 The imprinted LTG-1-C, and MECH-1-C forms must be signed on the plans
Note If you have any questions regarding this Electrical or Energy plan review
list please contact Morteza Beheshti at (858) 560-1468 To speed the review
process, note on this list (or a copy) where the corrected items have been
addressed on the plans
PLUMBING AND MECHANICAL CORRECTIONS
PLAN REVIEWER Glen Adamek
GENERAL AND ARCHITECTURAL PME ITEMS
1 Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes, before the permits are
issued Business and Professions Code The final set of corrected drawings to
be reviewed for signing and sealing just before the permits are to be issued
2 Correct the new Storage Rooms over 100 square foot in area to show the
required separation As per IBC, table 508 2 the incidental use areas for storage
rooms over 100 sq ft of floor area, shall be separated from the remainder of the
building by a fire barrier or if provided with an automatic fire extinguishing system
the separation must comply with IBC, Section 508 2 2 "the incidental use area
Carlsbad 08O879
May 23, 2008
shall be separated form the remainder of the building by construction capable of
resisting the passage of smoke The partitions shall extend from the floor to the
underside of the fire-resistance-rated floor/ceiling assembly or fire-resistance-
rated roof/ceiling assembly above or to the underside of the floor or roof
sheathing, or sub deck above Doors shall be self- or automatic closing upon
detection of smoke in accordance with Section 715473 Doors shall not have
air transfer openings and shall not be undercut in excess of the clearance
permitted in accordance with NFPA 80 "
3 Include, on the mechanical plans, the locations of all required smoke, fire,
combination smoke and fire, or ceiling radiation dampers Be sure to include a
symbol on the symbol schedule for each damper type IBC 716
4 Please correct the drawings to show the required "Guards" (guard rails) as per
IBC, Section 1013 5 "Where appliances, equipment, fans, roof hatch openings or
other components that require service are located within 10 feet of a roof edge or
open side of a walking surface "
PLUMBING (2006 UNIFORM PLUMBING CODE)
5 Show the public water meter location and size on the plumbing site plan
6 The existing 11/2 inch water mam serving this building seems to be under sized
for the total building water demand as per the water line sizing calculations on
sheet PO 2 Please correct the water line sizing from the public water meter to
the new fixtures
7 Please show the upstream sewer manhole rim and finished floor elevations
Provide backwater valves for all fixtures installed on floor levels below the next
upstream manhole rim elevation (Only fixtures installed on floor levels below
the next upstream manhole rim elevation may flow through a backwater valve )
UPC 710 1
8 Show 1/4 inch per 12 inch slope on dram and waste lines UPC Section 708 0
9 Hot water supplied to a public use lavatory or any bathtub is limited to a
maximum temperature potential of 120 degrees Detail how this temperature
limitation is achieved Note The water heater thermostat may not be used for
compliance with this Code section UPC 413 1 & UPC 414
10 Floors shall slope to the floor dram(s) location(s) Please detail on the
architectural floor plans UPC 4114
11 Provide the following information concerning the water heater
a) Show water heater size, type and location on plans UPC 501 0
b) Show that water heater is adequately braced to resist seismic forces
Provide two straps One strap at top 1/3 of the tank and one strap at
bottom 1/3 of the tank UPC 508 2
Carlsbad O8O879
May 23, 2O08
c) Show P & T valve on water heater and detail the dram routing to the
exterior It may not be installed upwards from the valve UPC 506 2/608 3
d) An expansion tank or other approved device is required if system pressure
relief is not available due to the installation of backflow devices or certain
pressure regulators Please address UPC 608 3
MECHANICAL (2006 UNIFORM MECHANICAL CODE)
12 Show the size, location, and types of all heating and cooling appliances or
systems
13 The mechanical plans seem to be incomplete and incorrect The ducting
through the roof and through the floor systems do not seem the match at each
floor level and the roof and the exhaust systems seem to be incomplete
14 Buildings of more than 15' in height shall have an inside means of access that
meets the design requirements of UMC 904 1033 Please provide City
approval for use of an outside ladder is required
15 Detail the primary and secondary mechanical condensate waste design Pipe
sizing, routing, and termination areas UMC 310 0 & UPC 807 2
16 Provide the exhaust and make-up air design for the occupancy type listed in
Table 4 4 UMC 403 7
17 Provide the independent ventilation or the air conditioning system required for
the elevator equipment room to prevent the overheating of the electrical
equipment IBC 3006 2
Note If you have any questions regarding this Plumbing and Mechanical plan review
list please contact Glen Adamek at (858) 560-1468 To speed the review process, note
on this list (or a copy) where the corrected items have been addressed on the plans
Carlsbad 080879
May 23, 2008
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO 08O879
DATE May 23, 2O08
JURISDICTION Carlsbad
PREPARED BY Abe Dohente
BUILDING ADDRESS 2055 Corte Del Nogal
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION V-B
BUILDING
PORTION
Office T 1,
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
Rldn Pprmif FPP bv Ordma
AREA
(Sq Ft)
27347
cb
Valuation
Multiplier
3437
By Ordinance
nee ^ !
Reg
Mod
VALUE ($)
939,916
939,916
$3,19425
Plan Check Fee by Ordinance
Type of Review
I I Repetitive FeeRepeats
Complete Review
D Other
r- Hourly
Structural Only
Hour*
Esgil Plan Review Fee
Comments
$2,07626
$1,78878
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB.DATE
ADDRESS.OoJi
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
(<$10,000.00)
NANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
J
PLANNER
ENGINEER
\(
DATE
DATE
(/
-Si .SJ"co 75Q Q
PLA?JNING'DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No CB080879 Address 2055 Corte del Noqal
Planner Deborah Milarri Phone (760)602-4619
APN 213-061-08
Type of Project & Use Jj Net Project Density DU/AC
Zoning P-M General Plan PJ Facilities Management Zone
CFD (in/out) #_Date of participation Remaining net dev acres
Circle One (For non-residential development Type of land used created by this permit
Legend Item Complete
D
D D
D D
Environmental Review Required
DATE OF COMPLETION
Item Incomplete - Needs your action
YES D NO D TYPE
Compliance with conditions of approval? If not, state conditions which require action
Conditions of Approval
Discretionary Action Required YES D NO D TYPE
APPROVAL/RESO NO DATE
PROJECT NO
OTHER RELATED CASES
Compliance with conditions or approval? If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES Q NO Q
CA Coastal Commission Authority? YES Q NO Q
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego, CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Habitat Management Plan
Data Entry Completed? YES D NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE')
Inclusionary Housing Fee required YES D NO D
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
Data Entry Completed? YES D NO D
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE')
H \ADMIN\Template\Buildmg Plancheck Review Checklist doc Rev 4/08
Site Plan
Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes)
Provide legal description of property and assessor's parcel number
D
Policy 44- Neighborhood Architectural Design Guidelines
1 Applicability YES D NO D
2 Project complies YES D NOQ
Zoning
1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope
Required
Required
Required
Required
Required
2 Accessory structure setbacks
Front Required
Interior Side Required
Street Side Required
Rear Required
Structure separation Required
Shown
Shown
Shown
Shown
Shown
Shown.
Shown
Shown.
Shown.
Shown
D D 3 Lot Coverage Required Shown
D D 4 Height Required Shown
Spaces Required Shown5 Parking n
(breakdown by uses for commercial and industrial projects required)"
Residential Guest Spaces Required Shown
Additional Comments Correction #1 Please show how new and moved roof-mounted equipment will
be screened from ground level view A side elevation of the building with proposed equipment and
mechanism of screening to scale will be fine
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
H \ADMIN\Template\Buildmg Plancheck Review Checklist doc Rev 4/08
Carlsbad Fire Department
Plan Review Requirements Category TI , INDUST
Date of Report 07-03-2008
S D C CORTE L L C
Reviewed by
Name
Address
7065 EL CAJON BLVD
SAN DIEGO CA
92115
Permit # CB080879 8LDG DEPT COPY
Job Name MC CONSULTANTS- 27,347 SF
Job Address 2055 CORTE DEL NOGAL CBAD
The item you have submitted tor review is incomplete At this
adequately conductaT^q^afetculetermine cqmnripp W1'1 fl'm "1 ] ' ..... '****<> ™
carefully all coming || , iUm In l] ^1 I i i n i
In |iiii irTTTTT ior review and approval
Conditions
cannot
- standards Please
illi i h in i i I ..... I I
Cond CON0002803
[NOT MET]
1 Sheets A2 5 & A2 6 - Illuminated exit signs shall be shown on electrical plans
Entry 05/27/2008 By cwong Action CO
Cond CON0002902
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Entry 07/03/2008 By cwong Action AP
Carlsbad Fire Department
Plan Review Requirements Category TI , INDUST
Date of Report 05-27-2008 Reviewed by >d
Name S D C CORTE L L C
Address
7065 EL CAJON BLVD
SAND1EGOCA
92115 QT DG DFPT COPYOJU.IL'Vl. LJX-jL L V^VJ'jr I
Permit # CB080879
Job Name MC CONSULTANTS- 27,347 SF
Job Address 2055 CORTE DEL NOGAL CBAD
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards Please review
carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval
Conditions
Cond CON0002803
[NOT MET]
1 Sheets A2 5 & A2 6 - Illuminated exit signs shall be shown on electrical plans
Entry 05/27/2008 By cwong Action CO
IPALOS
VERDES
(Engineering
Civil and Structural Consulting
O Please Respond To
6027-1 Paseo Dehcias
PO Box 2211
Rancho Santa Fe
California 92067-2211
858 759 2434
858 759 8324 FAX
ranchosantafe@pvec com
O Please Respond To
27520 Hawthorne Blvd
Suite 250
Rolling Hills Estates
California 90274-3512
310541 5055
310541 0321 FAX
info@pvec com
Structural Calculations
Tenant Improvement
Prepared For
Warren W Scott Architecture
987 Hermes Avenue
Encimtas, CA 92024
Project
MC Consultants, Inc
2055 Corte del Nogal
Carlsbad, CA
RCE C57182, expl2/31/09
PROJECT ENGINEER
April 23,2008
PVECFiIeNo 24-08-261
PALOS VERDES ENGINEERING CORPORATION
6027-1 Paseo Dehcias * P 0 Box 2211 * Rancho Santa Fe, CA 92067
Telephone (858) 759-2434 - Fax (858) 759-8324
1 0 Design Criteria
Code
Timber
MC Consultants, Inc
24-08-261
2007 California Building Code - ASCE 7-05
Douglas Fir-Larch (DF-L), WWPA or WCLIB
2x Wall Framing DF-L #2 (unless noted otherwise)
2x Rafters & Joists DF-L #2 "
Posts & Beams DF-L#1 "
Glue-Lam Beams
Sheathing
Engineered Framing
Concrete
Concrete Block
Mortar
Grout
Reinforcing Steel
Structural Steel
Simple Span
Cantilevers
Grade 24F-V4 (DF/DF)
Grade 24F-V8 (DF/DF)
Mm APA-Rated Sheathing, Exposure 1, Plywood or OSB (UNO)
Wood I-Joists
LVL, PSL
TJI 110,210,230,360,560 ICCESR-1153
1 9E Microllam, 2 OE Parallam ICBO ER-4979
Compressive Strength @ 28 days per ASTM C39-96
Footings f c = 2500 psi
Grade Beams f c = 3000 psi
Grade N-I per ASTM C90-95, f m = 1500 psi per ASTM E447-92
Type S Mortar Cement per ASTM C270-95, Mm f m = 1800 psi @ 28 days
Coarse Grout w/ 3/8" Max Aggregate per ASTM C476-91,
Mm f m = 2000 psi @ 28 days
#4 & Larger
#3 & Smaller
ASTM A615-60 (Fy = 60 ksi)
ASTM A615-40 (Fy = 40 ksi)
'W' Shapes ASTM A992, Fy= 50-65 ksi
Plates, Angles, Channels ASTM A36, Fy = 36 ksi
Tube Shapes ASTM A500, Grade B, Fy= 46 ksi
Pipe Shapes ASTM A53, Grade B, Fy=35 ksi
Welding Electrodes
Bolts
Soils
References
Structural Steel
A615-60Rebar
E70-T6
E90 Series
Sill Plate Anchor Botls & Threaded Rods
Steel Moment & Braced Frames
1000 psf Bearing Pressure
A307 Quality Minimum
A325 (Bearing, UNO)
Palos Verdes Engineering Corporation
Consulting Structural Engineers
6027-1 Paseo Delicias * P O Box 2211 * Rancho Santa Fe, CA 92067
Telephone (858) 759-2434 - Fax (858) 759-8324
JOB 24-08-261
SHEET NO 2.
CALCULATED BY
CHECK BY
SCALE
OF
PSC DATE
DATE
4/23/08
2 Q LOAD LIST
21 Roof (Vaulted)
Roofing 5 5 psf
15/32" Sheathing 1 5 psf
Roof Framing 4 0 psf
5/8" Gyp Bd 28 psf
Insulation and Misc 1 2 psf
SDL= 15 Opsf
SLL = 20 0 psf
Total Load = 35 0 psf
2 2 Roof (w/ ceiling)
Roofing 5 5 psf
15/32" Sheathing 1 5 psf
Roof Framing 4 0 psf
Insulation and Misc 1 0 psf
SDL= 12 Opsf
SLL = 20 0 psf
Total Load = 32 0 psf
2 3 Ceiling
Ceiling Joists 1 0 psf
5/8" Gyp Bd 28 psf
Insulation and Misc 1 2 psf
SDL = 50 psf
SLL= 10 Opsf
Total Load = 15 Opsf
2 4 Walls
Exterior Wall
Cone Wall 90 0 psf
Opsf
0 psf
0 psf
Opsf
SDL = 90 0 psf
Interior Wall
1/2" Gyp Bd (2 Sides)
2x4 Studs @ 16" o c
Misc
46 psf
1 1 psf
23 psf
2DL = 80 psf
Palos Verdes Engineering Corporation
Consulting Structural Engineers
6027-1 Paseo Delicias * P O Box 2211 * Rancho Santa Fe, CA 92067
Telephone (858) 759-2434 - Fax (858) 759-8324
JOB 24-08-261
SHEET NO
CALCULATED BY
CHECK BY
SCALE
OF
PSC DATE 4/23/08
DATE
2 0 LOAD LIST (CONTIN)
2 5 Floor
Floor Cover 5 5 psf
Sheathing 2 3 psf
2x F J 3 1 psf
5/8" Gyp Bd 28 psf
Insulation and Misc 1 3 psf
SDL= 150 psf
SLL = 50 0 psf
Total Load = 65 0 psf
(ASCE 7-Equation6-1)
WIND PARAMETERS
Basic Wind Speed = 85 mph Exposure Cat = C
A=135 (fig 6-3) Ps30= 11 5 psf (fig 6-3)
Kzt=100 (fig 6-4) 1= 10 (table 11 5-1)
(114-3)
USGS APPLICATION
Ss= 1 168 S,= 0442
Fa= 1 03 Fv= 1 56
R = 3 5 I = 1 00
hn= 2500
Occupancy Category 2
Site Class D
SEISMIC DESIGN CATEGORY
Cs = 0 23
USE
V= CSWDL
V= 0 230 WDL
ASP BASE SHEAR
v = CSWDLVASD 14
VASD= 0164WDL
] <075
] >004
(11 6 ASCE 7-05)
(1141 ASCE 7-05)
Equation 12 8-1 Applies = C,*(hn)u"= 0224
= SDI/SDS= 0459
k= 10
Seismic Design Category
Ta < (0 8)Ts, OK
Ta<05
D
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude = 33 12
Longitude = -117 278
Spectral Response Accelerations Ss and S1
Ss and S1 = Mapped Spectral Acceleration Values
Site Class B - Fa = 1 0 ,Fv = 1 0
Data are based on a 0 01 deg grid spacing
Period Sa
(sec) (g)
02 1 168 (Ss, Site Class B)
10 0 442 (S1, Site Class B)
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude = 33 12
Longitude = -117 278
Spectral Response Accelerations SMs and SM1
SMs = FaSs and SM1 = FvS1
Site Class D - Fa = 1 033 ,Fv = 1 558
Period Sa
(sec) (g)
02 1 207 (SMs, Site Class D)
10 0 688 (SM1, Site Class D)
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude = 33 12
Longitude = -117 278
SDs = 2/3 x SMs and SD1 = 2/3 x SM1
Site Class D - Fa = 1 033 ,Fv = 1 558
Period Sa
(sec) (g)
02 0 805 (SDs, Site Class D)
10 0 459 (SD1, Site Class D)
Palos Verdes Engineering Corporation JOB 24-08-261
| Lfln^^M Consulting Structural Engineers SHEET NO
^H.^^_ 6027-1 Paseo Delicias * P O Box 22 1 1 * Rancho Santa Fe, CA 92067 CHECK BY
l^^l Telephone (858) 759-2434 - Fax (858) 759-8324 SCALE
.......
•=.
—
—
_
L.I LJ_L_L_l_L_
4 0 FLOOR FRAMING
I
4 1
"'
4
_
...'.\
—
•~™~~^
(FB-l)
.~. ..
I "1
\ "
ii
[_
\42
! _;
':m^ ^
:
__
-
— r "'..._....i —
1•• \~ "-i-
••..... ..:\
, —
iI
1
j
t
\
-
i
__,
-|-
i_^ J
i ._!
3
!
..-.-
..._
„._.
-H
—
—
(FB-2)
!
...^...™~
—
(FB
j
I
|-
i
E
i
I
. j. ™,
~"h
~3)
"I
- - - i
~"Hr~j!~~f
i
!
^I1-
i
"""1?i
J*
_
I
Ii
h
^
—
_
BH
—
, ^. _
nhtr
je
-
14:
i-ii~h
—„,_
1 !
ri ._
IS
I
fii
—
f —
^
TA
—
__.,
—
i
i
j
1
r^fc
i
t jT"P«;
... ..}„ . *L_^L-
1
Tii —1
1
__J_
<? *
— •-•
a
i
^
i
iI
J
1 ~ T
! !
._
iJ
— :
r
_
""
_.
-^
IAJ&.
-—
--
....
— -
z
p
—
—
i
k
p
__.
—
*-L
—
—
—
i
j i
—§
-i
_u
uT~
_i_
1
'— »
—
->,2.
—
—
i
.— -
— i
f—
—
^
P
— ~
-?
i_
—
"^S
/
=
1
-
—
&
.......
»«
H
_....
—
G
" !
/
—
j
i
—
1 j
__|
qjH
— ,j
C£
zj
|
!-
"1 ! 1
—
-- — '
--
E
--
—
—
—
—
1«
....
i
I
—-7
-
_
^j...
i
—
i
i
—
......1™ -
i
—
d
_
f—
I i!r —
!
l_
,, —
1
!i
hl:^
r '"i- - - 1 -
ii:r~rr
.....
•/i
—
<c
rff™.,.
L»
J
——
t<~T~
IS'! j.*.......
•- to\t J
..-.^HK
i
_._.
i
t~ "™"
{
I
i
[ j[T_
PSC
OF
DATE 4/23/08
DATE
"~
—
rr«-
?
—
E
i$'—
IT»!)•
!.. _T _
!
1i
_
^jN
M
ISII
/
r
Tf]
F-I
[
i4
1 "~"ii_L
^
—
-
I• t
F
-
»
_.
T""
1-
1
f-
SUL*.
|-
i
_
—
lew4t
i
!
i
j
!
i
!
1 J-
Ut.^Sr
.f' ?
i^i^i
i
|_
iir!t— t—j i" "i "
"
'"""""
.......
14
! 1
T i[ !j
i^
-H i
i,. 1 .- „_..!
7"; —
»#
^
y
.1<£•
... -j
_J
^ ?
_
.«rl|>v 1ff 1
! i
to.j
- —
_ i
1~r ~
-Sojp
: olwl™ r —
|
i
j
-
—
1
a:
H
?T
_,
1
-flM
i
!
i
TO.I"T
SSXX& Ey~
M.
.^*J]
_J_
1
1
~~l
.. —
i1
-W?—
y S
L%*<
i
n-|;,.__f
z.:1
~ t i••--•f •• i
1I
>0
""""
_.
..v- ^^
"
I
-h
s
r
.. |
._...
—
I Verdes Engineering Corporation
Consulting Structural Engineers
6027-1 Paseo Dehcias * P O Box 2211 * Rancho Santa Fe, CA 92067
Telephone (858) 759-2434 - Fax (858) 759-8324
JOB 24-08-261
SHEET NO <
CALCULATED BY
CHECK BY
SCALE
OF
PSC DATE 4/23/08
DATE
Palos Verdes Engineering Corpation
6027 J Paseo Delicias
PO Box 2211
(858)7592434
(858) 759-8324 (Fax)
paul(5)pvec com Printed 29 APR 2008
Description (FBI)FlrBm
Material Properties Calculations per IBC 2006, CBC 2007, 2005 NDS
Analysis Method Allowable Stress Design
Load Combination 2006 IBC & ASCE 7-05
Wood Species Truss Joist
Wood Grade Parallam 2 OE
Fb Compr
Fb Tension
Fc Prll
Fc - Perp
Fv
Fti ._ i i i .
2900 psi
2900 psi
1600psi
650 psi
290 psi
1000 psi
£ Modulus of Elasticity
Ebend-xx 2000 ksi
Emmbend-xx Oksi
Density 34 15pcf
Beam Bracing Beam is Fully Braced against lateral-torsion buckling
D(0 385) L(0 635)
2~"25 25x16 0
180ft
Applied Lbjicis Service loads entered Load Factors will be applied for calculations
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load D = 0 3850, L = 0 6350 k/ft Tributary Width = 1 0 ft'
Maximum Bending Stress Ratio =
Section used for this span
fb Actual =
FB Allowable
i Load Combination
i Location of maximum on span =
, Span # where maximum occurs =
I Maximum Deflection
i Max Downward Live Load Deflection
Max Upward Live Load Deflection
i Live Load Deflection Ratio
Max Downward Total Deflection
Max Upward Total Deflection
' Total Deflection Ratio
0778 1
5 25x16 0
2 256 16 psi
2 900 00 psi
-t-D+L+H
8 940ft
Span # 1
0 423 in
0 000 in
510
0 693 in
0 000 in
311
Maximum Shear Stress Ratio
Section used for this span
fv Actual
Fv Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Support Reactions ( kips )
D L+Lr S W
Support #1
Support #2
364
364
572
572
0491 1
525x160
142 45 psi
290 00 psi
+D+L+H
16671ft
Span # 1
H
iiOverall Maximum Deflections - Unfactored Loads
Load Combination Span Max " Defl Location in Span Load Combination Max "+ Defl Location in Span
^ ..... „. ..........
Maximum Deflections^foRLoadiCombinations
.m „ 9060. ^
Unfactbfed^MdsW'^"
00000 0000
Load Combination Span Max Downward Defl Location in Span Max Upward Defl Location in Span
DOnly
Lr+L Only
Maximum Reactions-'Unfactored
0 2697
0 4230
0 6927
9 060
9 060
9 060
00000
00000
00000
0000
0000
0000
Load Combination Support Vertical Reaction
Overall MAXimum Support 1 (D+Lr + L)9359
Palos Verdes Engineering Corpation
6027fPaseoDelicias
PO Box2211
(858) 759 2434
(858) 759-8324 (Fax)
paul@pvec com
Title
Dsgnr
Project Desc
Project Notes
Job#
Printed 29 APR 2008
Rte.ttaf bKkuptaetfold^
': ''' '':" N27083';-
Description (FB 2) Fir Bm
Material Properties Calculations per IBC 2006, CBC 2007, 2005 NDS
Analysis Method Allowable Stress Design
Load Combination 2006 IBC & ASCE 7-05
Wood Species Truss Joist
Wood Grade Parallam 2 OE
Fb - Compr
Fb Tension
Fc-Prll
Fc - Perp
Fv
Ft
2,900 0 psi
2 900 0 psi
1 ,600 0 psi
650 0 psi
290 0 psi
1 ,000 0 psi
£ Modulus of Elasticity
Ebend xx
Emmbend - xx
Density
2 000 Oksi
ksi
34 150pcf
Beam Bracing Beam is Fully Braced against lateral-torsion buckling
D(3525).L(5875)
D(0 058) L(0 062)
5 25x16 0
190ft
fAppliel'Loads;:'Wijt ,-. ,i -*9fi:--",v,--1 Service loads entered Load Factors will be applied for calculations
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load D = 0 0580, L = 0 0620 k/ft, Tributary Width = 1 0 ft
Point Load D = 3 5250, L = 5 8750 k (5) 6 260 ft
083Q 1
525x160
2 408 41 psi
2 900 00 psi
+0+L+fl
6248ft
Span # 1
0 400 in
0 000 in
569
0 674 m
0 000 m
338
Maximum Bending Stress Ratio =
Section used for this span
fb Actual =
FB Allowable
Load Combination
Location of maximum on span =
Span # where maximum occurs =
Maximum Deflection
Max Downward Live Load Deflection ;
Max Upward Live Load Deflection :
Live Load Deflection Ratio ••i
Max Downward Total Deflection ;
Max Upward Total Deflection ;
Total Deflection Ratio
Maximum Shear Stress Ratio
Section used for this span
fv Actual
Fv Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Support Reactions ( kips)
D _ L+Lr i
Support #1 " ~310"~ 453"
Support#2 190 252
W
0459 1
525x160
133 10 psi
290 00 psi
+0+L-I-H
0000ft
Span#1
H
.Overall Maximum peflMtiohs^UrifadQretfLpafs
Load Combination Span Max "" Defl Location in Span Load Combination Max +"Defl Location in Span
D+Lr 1 06742 8799 00000 0000
Maximum Deflections for Load Combinations Unfactored Loads
Load Combination
DOnly
Lr+i Only
D + Lr + L
Span
1
1
1
Max Downward Defl
02737
04005
06742
Location in Span
8926
8799
8799
Max Upward Defl
00000
00000
00000
Location in Span
0000
0000
0000
Palos Verdes Engineering Corpation
6027 I'Paseo Dehcias
PO Box2211
(858)7592434
(858) 759-8324 (Fax)
paul(5)pvec com
Wood Beam Design
Title
Dsgnr
Project Desc
Project Notes
Job#
V
Printed 30 APR 2
Re \\rsf backupUietfoldertJobs on CApp\PC\2p08\08-261-MCScoffiCalc\mccon ec6
Description (FB3)RrBm
Material Properties Calculations per IBC 2006, CBC 2007 2005 NDS
Analysis Method Allowable Stress Design
Load Combination 2006 IBC & ASCE 7-05
Wood Species Truss Joist
Wood Grade Parallam 2 OE
Fb Compr
Fb Tension
Fc-Prll
Fc Perp
Fv
Ft
Beam Bracing Beam is Fully Braced against lateral-torsion buckling
D(024
D(0 33) L(0 5£j
T V V V '
L(0 4) D(0 36)
) D(0117)L(0163)
' V t * T '/ Tr-1'r "i
2S
^
L(1 65)
5 25x18 0
2,900 0 psi
2,900 0 psi
1 ,600 0 psi
650 0 psi
290 0 psi
1 0000 psi
D(036)L(1
D(0 238) L(0
Y
E Modulus of Elasticity
Ebend-xx 2,000 Oksi
Emmbend - xx ksi
Density 34150pcf
65)
363)
V T
^^M'^^?* /^i^gm^^r:^.r> *•'-.;
22 250 ft
Applied Loads Service loads entered Load Factors will be applied for calculations
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load D = 0 330, L = 0 550 k/ft, Extent = 0 0 -» 2 330 ft, Tributary Width = 1 0 ft
Uniform Load D = 01170, L = 01630 k/ft, Extent = 2330-»9080 ft Tributary Width = 1 0 ft
Uniform Load D = 0 2380, L = 0 3630 k/ft Extent = 9 080 -» 22 250 ft Tributary Width = 1 0 ft
PomtLoad D = 0240 L = 040k(g)2330ft
Point Load D = 0 360, L = 1 650 k @ 9 670 ft
PomtLoad D = 0360 L= 1 650k(5) 15670ft
DESIGN SUMMARY ' ? iLj
Maximum Bending Stress Ratio = 0 728 1
Section used for this span 5 25x18 0
fb Actual = 2,111 19psi
FB Allowable = 2,900 OOpsi
Load Combination +D+L+H
Location of maximum on span = 11349ft
Span # where maximum occurs = Span # 1
Maximum Deflection
Max Downward Live Load Deflection = 0 568 in
Max Upward Live Load Deflection = 0 000 in
Live Load Deflection Ratio = 470
Max Downward Total Deflection = 0 867 m
Max Upward Total Deflection = 0 000 in
Total Deflection Ratio = 308
Maximum Shear Stress Ratio
Section used for this span
fv Actual
Fv Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Support Reactions ( kips)
D L+Lr £
Support #1 " ~ 302 523""
Support #2 313 564
0429 1
525x180
124 43 psi
290 00 psi
+D+L+H
20757ft
Span # 1
W H !
jOyerall Maximum Deflections • Unfactored Loads ;,
Load Combination Span Max "" Defl Location in Span Load Combination Max "+ Defl Location in Span
Lr + L 1 08668 11349 00000 0000
Maximum Deflections for Load Combinations - Unfactored Loads
Load Combination Span Max Downward Defl Location in Span Max Upward Defl Location in Span
DOnly
Lr-H. Only
02991
05676
11349
11349
00000
00000
0000
0000
Palos Verdes Engineering Corporation
Consulting Structural Engineers
6027-1 Paseo Delicias * P O Box 2211 * Rancho Santa Fe, CA 92067
Telephone (858) 759-2434 - Fax (858) 759-8324
JOB 24-08-261
SHEET NO
CALCULATED BY
CHECK BY
SCALE
OF
PSC DATE 4/23/08
DATE
6 0 FOUNDATION DESIGN
6 1 CONTINUOUS FOOTING
w= 1125 plf
width = 1125 plf = 1125 ft (MIN) => 14 INCHES (MIN )
1000 psf
( E ) 15 " WIDE CONTIN FTG W/
1 - # 4 TOP AND BOTTOM & EMBED
18 " INTO UNDISTURBED SOIL (MIN )
ASBP= 1000 psf
6 2 MAX POINT LOAD ON FOOTING
i
\
\
Pall = 1000 * 15 * 48
12 12
Pall= 5000 Ibs
6 3 PAD DESIGN
PAD
PI
P2
SIZE
36 "SQUAREx 12 " THK
W/ 4 -# 4 EACH WAY
48 "SQUAREx 12 "THK
W/ 5 -# 4 EACH WAY
LOAD
Pmax= 1000 *
Pmax= 9000 Ibs
Pmax= 1000 *
Pma,= 16000 Ibs
MasterguardT Series
CASH ACME
DESCRIPTION
The Masterguard3 Series is a range of six high flow rate Temperature Actuated Mixing Valves
from 3/4" to 2" that mix hot water with cold to deliver tempered water at a controlled
temperature, typically 120 F (49 C), 150 F (65 C) maximum
The Masterguards® are central mixers intended for installation in the plant room of commercial
and industrial facilities to distribute controlled temperature water to the domestic hot water
system of a whole building or a whole section of a building
The Masterguard® valves are state of the art incorporating the latest in Thermostatic Technology for
superior performance The Masterguard51 thermostatic mechanism is based on proven expanding
wax technology that provides greater accuracy, faster response to temperature changes and greater
resistance to corrosion and failure than earlier technology The Masterguard8 Series incorporates
fast acting high quality thermostatic elements that sense the outlet water temperature and react to
maintain a stable delivery temperature even under varying and extremely low flows The valves also
greatly reduce the outlet flow in the event of a cold water supply failure
The Masterguard0 valves feature a robust design based on the expertise gained from years of
experience in the design and manufacture of safety valves Every valve is tested for performance
on an automated testing station dunng the assembly process The valves are ASSE 1017 listed
The Masterguard® valves feature an adjusting handle that can be locked at a desired temperature
Alternatively it can function in an adjusting mode, with the handle clearly marked to indicate the
direction to turn to achieve hotter or colder water temperatures
Each Masterguard® valve has integral mounting feet to allow it to be securely fixed to a wall or frame
The Masterguards® are complete with 4m1 Service Fittings on each inlet The 4m1 Service
Fittings provide
1 Integral ball valve isolator
2 Large area cylindrical strainer
3 Gauge/flushing port to measure pressure or as flushing point
4 Check valves to prevent cross connection of hot to cold
The Service Fittings have a female inlet thread and connect to the base valve via union connections
The valve outlets are female NPT threaded The Masterguard8 valves range in size from 3/4" to 2"
FEATURES AND BENEFITS
Accurate temperature control even at very low flows
Faster to commission, greater user comfort and safety
Integral mounting feet on valve body
No extra brackets to buy, lower cost and more secure installation
Fast reaction to changes in flow rate or supply temperature
Constant outlet temperature for greater comfort
Robust, low complexity construction based on proven Thermostatic Technology
Superior reliability, improved user safety
Listed by IAPMO and ASSE
Inspector friendly peace of mind'
SPECBFICATION
A Temperature Actuated Mixing Valve shall be installed at the hot water source to distribute
tempered water throughout the domestic hot water system at a maximum of 150 F (65 C)
The valve shall have a thermostatic control mechanism based on the expanding wax principle
and shall have integral mounting feet Each valve shall have integral poppet style check valves
on both inlets with a positive seal of the poppet onto an elastomer seat to prevent cross
connection from hot to cold The valve shall be complete with integral ball valve isolators,
strainers check valves and gauge/flushing ports on each inlet The valve shall be a Cash
Acme Masterguard9
MASTERGUARD
THERMOSTATIC MIXING VALVES
A Division of the Reliance Worldwide Corporation
CASH ACME
Masterguard Series
TYPICAL INSTALLATION
The Masterguards8 are central mixers intended for installation in
the plant room of commercial and industrial facilities to distribute
controlled temperature water to the domestic hot water system of
a whole building or a whole section of a building
r
-._....
Recifculation Piping Diagram
SPECIFICATION DATA
Measurement in inches
Product
810
820
830
840
850
860
Inlet
1/2
3/4
3/4
1
1 1/4
1 1/2
Outlet
3/4
3/4'
1
1 1/4
1 1/2"
2
Flow at
45 psi
19 gpm
30 gpm
51 gpm
75 gpm
105 gpm
149 gpm
Mm flow
rate*
1 gpm
2 5 gpm
4 gpm
8 gpm
13 gpm
1 8 5 gpm
A
55
67
9 2
102
1275
130
B
22
24
24
28
25
2 5
C
7 1
8 1
100
102
137
137
D
98
11 3
13 1
136
163
163
E
1 2
1 3
1 7
1 7
1 9
1 9
F
39
49
67
65
9 3
9 3
G
20
24
35
35
51
5 1
H
1 1
1 3
1 9
1 9
1 9
1 9
"Valve can regulate temperature of lower flow rates with a properly designed recirculatmg system
Performance
Outlet temperature range 95 -150 F (35 - 65 C)
195 F (90 C) maximum
40 - 80 F (4 - 27 C)
+/- 5 F (3 C)
145psi(1,OOOkPa)
Temperature hot supply
Temperature cold supply
Temperature stability
Working pressure Maximum
Materials
Body
Seals
Springs
Fitting
Internal
Piston
CERTIFBCATIONS*
Bronze, nickel plated
Nitrile elastomer
Stainless steel
Brass
Brass
Engineered polymer (810 820), PTFE Coated Brass (830 860)
80
Flow Rate (gpm)
120
The Cash Acme Masterguard* Series is certified to ASSE 1017 and CSA B125 3
The Cash Acme Masterguard3 Series is listed by ASSE and IAPMO
160
A Division of the Reliance Worldwide Corporation 07 CAC-03- 1? 13 07 Printed in USA
Masferguard Installation & Minimum Flows
RECIRCULATION PIPING DIAGRAM
CASH ACME
TEMPERED WATER
SUPPLY TO SYSTEM
TEMPERED WATER
RETURN FROM SYSTEM
V ISOLATING BALL VALVE
A (OPTIONAL)
ADJUSTMENT
BALL VALVE*
CIRCULATING
PUMP
* Ball Valve provides
regulation of recirculation
This ensures correct
recirculation temperature
COLD WATER
SUPPLY
The Minimum flow rate for all Cash Acme Masterguard mixers is 5 GPM
Note This minimum flow rate is only applicable when the valve is installed as per
the above diagram and in accordance with the instructions provided on the valve
A Division of the Reliance Worldwide Corporation 07 CAC i?8 4 17 03 Prnlocl in USA
X to0) Z
10-17-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR08119
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Reference #
PC#
Project Title
2055 CORTE DEL NOGAL CBAD
PCR
2130610800 Lot# 0
$0 00 Construction Type 5B
MC CONSULTANTS REVISIONS
Status ISSUED
Applied 10/07/2008
JMA
10/17/2008
10/17/2008
Entered By
Plan Approved
issued
Inspect Area
Applicant
SEAN KABO
760-930-9966
Owner
S D C CORTE L L C
7065 EL CAJON BLVD
SAN DIEGO CA 92115
Plan Check Revision Fee
Additional Fees
$12000
$000
Total Fees $12000 Total Payments To Date $12000 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review, set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
EsGii Corporation
In (Partnership -with government for (Building Safety
DATE October 15, 2008 Q APPLICANT
JURISDICTION Carlsbad dTpTATTREVIEWER
a FILE
PLAN CHECK NO 080879 Rev 2 (PCR08-119) SET I
PROJECT ADDRESS 2055 Corte del Nogal
PROJECT NAME Office T I for MC Consultants
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
X3 Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
XI REMARKS Revision 2 includes minor changes per memo dated 10/6/08
By Abe Dohente Enclosures
Esgil Corporation
D GA D MB D EJ Cj PC 10/9/08
9320 Chesapeake Drive, Suite 208 ^ San Diego, California 92123 ^ (858)560-1468 ^ Fax (858) 560-1576
City of Carlsbad
Plan Check Revision No
Project Address
Contact
Building Department
\ °[ Original Plan Check No C&O8"OSri°J
i Date /o/ t[
Address S2J5-
Ph/76Q) <7 3 D -IS 6<^ Fax
f/fl . ^.A£LiSCA/\ £Ar *
~ 9? "7
General Scope
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised
0 Plans D Calculations D Soils D Energy Q Other
2
Describe revisions in detail
Sx?.^. A-rrA^rn
3
List page(s) where
each revision is
shown
4
List revised sheets
that replace
existing sheets
ij
5 Does this revision, in any way, alter the exterior of the project?
O Does this revision add ANY new floor area(s)? Q Yes
T Does this revision affect any fire related issues? |~~| Yes
8 Is this a complete set? fj Yes
^Signature >^^IL@/~
1635 Faraday Avenue Carlsbad CA 92008
Yes No
Phone 760-602-2717/2718/2719/2721 Fax 760-602-8558
City of Carlsbad
Plan Check Revision No
Project Address
Contact
Address
Building Department
Original Pfan Check No c^gg frc? y- 7 ?
Q<Z-<- A/og-A( _ Date _ /0//7/Q?
Ph 0 ~ ? ?7
/ 1 , ci\-
General Scope of Work
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised/
Plans
2
Describe revisions m detail
" dWA/U^fe 1 f^rurt.fS
' /VO/} Jp\_<2C^\f~ /£O^t£> - 1/JII2-IAJ4JU6- TO pxi $TUJ(r
t4VJk£. (JtJ\,T2> £.£i/lS£LA Ou^TL-CJT L^AmfV-5 S
Qvjfe, T"«> LOAL(_ % f^o/A^^^^-3 ^rt"X^A>Cr-CS
- A/)0)fclO £>U T"l_2LT 3> 3 F"V_ciCb^. H3^^-£_S
^ Stto,^ El^^. TO A.L.U t^C^= T^^P
3
List page(s) where
each revision is
shown
&- z-,\
<£- 2-.-2-
V 2. t/
E. 2..S-
4
List revised sheets
that replace
existing sheets
^ i, )
£~ 2 . 2_
tz: z,y
C- -2 '^
5 Does this rev/sion, in any way, alter the exterior of the project? Q Yes
6 ^^^^^^Does this revision add ANY new floor area(s)? LJ Yes 0 No
/ Does this revision affect any fire related issues? Q] Yes
8 Is this a complete set? D Yes
^Signature "v^^.^
1635 Faraday Avenue Carlsbad CA 92008
No
Phone 760-602-2717/2718/2719/2721 Fax 760-602-8558
Warren W Scott + Architecture
Protect As-built Changes and Field Modifications
October 06, 2008
Project MC2 Consultants Tl, 2055 Corte Del Nogal, Carlsbad
Contractor MC3 Consultants
Drawings submitted with the following changes
1 Sheet A2 1 First Floor Plan
a Remove wall and enlarge storage area (Room 1-103)
b Remove wall between two offices to make one room and remove one door (Room 1-
125)
c Add windows to offices (1-115, 1-118, 1-145, 1-152)
d Relocate opening to Copy-1 (Room 1-110)
2 Sheet A2 2 Second Floor Plan
a Remove wall between two offices to make one room and remove one door(Room 236)
b Add window to office (Room 241)
c Add angled wall in Room 205
3 Sheet A4 2 Stair Details
a Revised post support detail at existing footing (Detail 16/A4 5)
b Provided referenced details for guardrail attachment (Details, 4,8,12/A4 5)
4 Sheet A4 5 Details (new sheet)
a Provided plan and detail for relocation of existing roof hatch (Detail 2/A4 5)
b Provided details for guardrail attachment (Details, 4,8,12/A4 5)
c Provided detail for stair support post/plate (Detail 16/A4 5)
5 Sheet S2 2 Second Floor Framing
a New detail (Post Detail 2) for field installed header
b
6 Sheet S2 3 Second Floor Framing
a New detail (Post to Beam Dtl 1) for connection not detailed
763 2* Street • Suite 200 • Encinitas • California • 92024 • 760 943 8180 • FAX 760 943 0119
££s
ApprovedBuildingCOc
_raa.Engineeringaj
iZ
"*-
aoU-
,£
1
>,| H<i7.Mat/Air Qual1
1
ou
DOc
15
3
MC
cc
HI
1 Engineering JK[£
£•1Q•o1a
I
£
z
J
V)
z
Qu.U
Z
a.
Z
PE&Mz
CL.
C
"2
V)
Z
XcZ
z
I Fees Completefu"QIMaaTe
4]c1
§8W (f)
S 21•2 o:
8^2 =>
18
2^
Oo
0mu
1"
0
@)
^J
o
r
"o"
11-06-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR08126
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Reference #
PC#
Project Title
2055 CORTE DEL NOGAL CBAD
PCR
2130610800 Lot*
$0 00 Construction Type
CB080879
MC CONSULTANTS- ELECTRICAL
REVISIONS
0
NEW
Status
Applied
Entered By
Plan Approved
issued
Inspect Area
Applicant
SEAN KABO
STE110
5315AVENIDAENCINAS 92008
760 930 9966
Owner
S D C CORTE L L C
7065 EL CAJON BLVD
SAN DIEGO CA 92115
ISSUED
10/17/2008
LSM
11/06/2008
11/06/2008
Plan Check Revision Fee
Additional Fees
$12000
$000
Total Fees $120 00 Total Payments To Date $12000 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will ba any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
EsGii Corporation
In Partnership with government for (Building Safety
DATE 10/24/08
JURIS>,
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO PCR08-126 (08-0879 original) SET I
PROJECT ADDRESS 2055 Corte Del Nogal
PROJECT NAME Misc revisions
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted" Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Morteza Beheshti Enclosures
EsGil Corporation
D GA D MB D EJ D PC 10/20
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560 1576
\
Carlsbad PCR08-126 (08-0879 original)
10/24/08
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
0879 original)
PREPARED BY Morteza Beheshti
BUILDING ADDRESS 2055 Corte Del Nogal
BUILDING OCCUPANCY TYPE OF CONSTRUCTION
PLAN CHECK NO PCR08-126 (08-
DATE 10/24/08
TOTAL VALUE
Jurisdiction Code cb
Bldg Permit Fee by Ordinance ^
Plan Check Fee by Ordinance ^
By Ordinance
$12000
Type of Review Q Complete Review D Structural Only
[^Repetitive Fee
~~~~< Repeats^ ;
Based on hourly rate
D Other
r-i Hourly Hour*
Esgil Plan Review Fee $9600
Comments ELECTRICAL PLAN REVIEW ONLY
Sheet 1 of 1
macvalue doc
Carlsbad Fire Department
Plan Review Requirements Category PCR ,
Date of Report 11-05-2008
SEAN KABO
Reviewed by
Name
Address
STE110
5315 AVENIDA ENCINAS
CARLSBAD 92008
FILE COPY
Permit # PCR08126
Job Name MC CONSULTANTS- ELECTRICAL
Job Address 2055 CORTE DEL NOGAL CBAD
__^^^MHM
is incomplete At this time, this office cannot
adequately conduct a review tod&kerffTme compliance wnn TJ-.P a| I'lin ihi« JP^ ^nri/r..- standards Please review
carefully all commeiits^tttfCned Please resubmit the necessary plans and/or speulicaiiolis^with changes "clouded",
to this officeJpjH^iew and approval
Conditions
Cond CON0003140
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Entry 11/05/2008 By cwong Action AP
City of Carlsbad
Plan Check Revision No
Project Address Z-£><£*$~ C£>a--r£.
Contact _
Address.
Building Department
.Original Plan Check No
Ph
a o
General Scope of Work
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
I Elements revised
Plans D Calculations D Soils D Energy D Other _
2
Describe revisions in detain
" dtt-A/LUWi i f^T^fS
A"00 f-^tXuf. (^O>«.C> . UM Q- i/O 4JUG- TO Flxi 3 7~/.A^£r-
tH/A£ L^A-'L^r^ ^-Ei/iS^A OL^TL-^LT L<X. Aerify-* S
(k/fero LOAtc ^ Lo/A/tf6U> ^1+XUX.C^
- A^O^rO ^>ut~u.£r5> Sj F~u.CiC>/2. )3^x-£.^>
^ SHt^,^ IcX^d TO A.UW. t-oc*= E^.^iP
5 Does this revision, in any way, alter the exterior of the project?
6 Does this revision add ANY new floor area(s)? Q Yes
7 Does this revision affect any fire related issues? Q Yes
8 Is this a complete set? Q Yes 0No
3
List page(s) where
each revision is
shown
&- z-,\
G- 2.. -2.
¥- *• H
1Z- 2..S-
D Yes E^TNO
4
List revised sheets
that replace
existing sheets
-£ Z| ,
^L '2.. Z.
&. 2..*]
^ -2.S-
fNo
1635 Faraday Avenue Carlsbad CA 92008 Phone 760-602-2717/2718/2719/2721 Fax 760-602-8558
*•s «
a
e•eni'
3o
| i
® 2
07-30-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR08076
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Reference #
PC#
Project Title
2055 CORTE DEL NOGAL CBAD
PCR
2130610800 Lot#
$0 00 Construction Type
CB080879
MC CONSULTANTS STRUCTURAL
CHANGES ROOF HATCH RELOCATED
0
NEW
Applicant
MC3 CONSTULTANTS INC
STEE
5245 AVENIDA ENCINAS 92008
760 930 9966
Status
Applied
Entered By
Plan Approved
issued
Inspect Area
Owner
S D C CORTE L L C
7065 EL CAJON BLVD
SAN DIEGO CA 92115
ISSUED
07/21/2008
JMA
07/30/2008
07/30/2008
Plan Check Revision Fee
Additional Fees
$18000
$000
Total Fees $180 00 Total Payments To Date $18000 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required 'nformation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water md sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise exoired
EsGil Corporation
In (Partnership rtntfi government for Quitting Safety
DATE 7/29/08 O^AEEUCANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO CB080879 REV 1 (PCR 08-76) SET I
PROJECT ADDRESS 2055 Corte Del Nogal
PROJECT NAME Revisions to Office TI for MC Consultants, INC
| The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
- Person contacted Telephone #
Date contacted (by ) (f Fax #
Mail Telephone Fax In Person
X] REMARKS 1) The red-bubbled change onlfevjeecl sheet S2 2 needs to be made on the
revised sheet S2 2 held at the City 2) Theapproved revised sheets need to be slipped
into the originally approved plans (both/sets) Thank you
By Tamara Fischer for Abe Dolierite Enclosures
Esgil Corporation
D GA D MB D EJ D PC 7/22/08
9320 Chesapeake Drive Suite 20S 4 San Diego California 92123 4 (858)560-1468 4 Fax (858) 560-1576
Carlsbad CB080879 REV 1
7/29/08
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO CB080879 REV 1
PREPARED BY Tamara Fischer for Abe Dohente DATE 7/29/08
BUILDING ADDRESS 2055 Corte Del Nogal
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VB
BUILDING
PORTION
Revisions
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
cb
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE ($)
Bldg Permit fee by Ordinance '
Plan Check Fee by Ordinance '
Type of Review D Complete Review
$18000
D Structural Only
Repetitive FeeRepeats
Based on hourly rate
Comments
D Other
m Hourly 1 5 Hours
Esgil Plan Review Fee $14400
Sheet 1 of 1
macvalue doc
City of Carlsbad
Plan Check Revision No \CJ(L QJ"
Project Address
Contact S^W £A&Q _ Ph
Address
Building Department
Original Plan Check No
Date
1 5" Av£A//flA HO /C&
FaxT7frO) *t ?Q -
APN
Business at this address
General Scope of Work-
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised
Plans Calculations Soils Energy n Other
2
Describe revisions in detail
STAipC-T'-'i^-A1^ Ctt^^^-fc ^> G^.^y\\ ^ l(*,\^\ "2.<3
Sv-fl^uvvLfte. ctt/w^i MK<L^^f^ti £ewiid,o
Sut^iM^c ru**/^'* SriCuiJLb i l^fAL^r Sjfftr
IVCOf- HATf 1+ ^•fco^A'TCL^
3
List page(s) where
each revision is
shown
. , J <;
^* \}f — * — ' \ v
S2_. z.
§Z ^
A- 3,3
4
List revised sheets
that replace
existing sheets
Sl.Z_
S2.,-2_
52.^
A: a?
5 Does this revision, in any way, alter the exterior of the project? Q Yes 0 No
O Does this revision add ANY new floor area(s)? Q Yes 0^ No
7 Does this revision affect any fire related issues? Q Yes 0 No
8 Is this a complete set that replaces the original permitted set? (§ff Yes ^j^No
1635 Faraday Avenue Carlsbad CA 92008 Phone 760-602-2717/2718/2719/7541 Fax 760-602-8558
City of Carlsbad
Plan Check Revision No \C*%L QJ"
Project Address 1O^ dd^-TIc, &£l
Contact StpW ViA&o _ Ph
Address r^ilT /\V£A/;/lA
Building Department
Original Plan Check No
Date
?<3 -
HO APN
Business at this address
General Scope
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised
Plans Calculations Soils Q Energy Q Other
Describe revisions m detail List page(s) where
each revision is
shown
List revised sheets
that replace
existing sheets
3 3 /v a
5 Does this revision, in any way, alter the exterior of the project?
6 Does this revision add ANY new floor area(s)?
7 Does this revision affect any fire related issues?
8 Is this a complete set that replaces the original permitted set?
LL&J -
Yes
Yes
Yes
Yes
No
No
No
1635 Faraday Avenue Carlsbad CA 92008 Phone 760-602-2717/2718/2719/7541 Fax 760-602-8558
Warren W Scott + Architecture
Structural Calculations
July 18, 2008
Project MC2 Consultants Tl, 2055 Corte Del Nogal, Carlsbad
Contractor MC3 Consultants
Additional Calculations
The attached are structural calculations for the supporting beam for the movable wall
system at the second floor See sheet S2 3 for plan and S12for details
Warren
Warren J/P Scott + Architecture
WSA,
C0£> <F-<D
Palos Verdes Engineering Corporation
Consulting Structural Engineers
6027-1 Paseo Dehcias • P O Box 2211 • Rancho Santa Fe, CA 92067
Telephone (858) 759-2434 • Fax (858) 759-8324
JOB 2.V OF,
SHEET NO \OF
CALCULATED BY
CHECKED BY
SCALE
DATE
DATE
MCZ.
; Lh
WAIL
(JT-o
6^*
6.10
^erdes Engineering Corpation
I Paseo Dehcias
0 Box 2211
^058) 759 2434
(858) 759-8324 (Fax)
paul@pvec com
Title
Dsgnr
Project Desc
Project Notes
Job#
2/2
Printed 16JUN2008
s.v <;• S« * file. msf-badiup\nettolteMobs on CADD1PC12008B8-261, MCScofftCatelmccon «;6, •
-^^i •• ^MLv- A •
Description Movable Partition Wall Beam
Material Properties
ENERCAICC
IticenMQwneifSfAllQSiVEBDESIENGINEERINGIEqRBi
Calculations per IBC 2006, CBC 2007,13th AISC
Analysis Method Allowable Stress Design
Beam Bracing Beam is Fully Braced against lateral torsion buckling
Bending Axis Major Axis Bending
Load Combination 2006 IBC & ASCE 7-05
Fy Steel Yield
E Modulus
50 0 ksi
29 000 0 ksi
D(0 076)
'
¥@s«xs;t:?si;
i
* V V
W10X22
i
v^^^^;^; '•^^^p^-^fe'-"'^
^
* 31 son
loads Service loads entered Load Factors will be applied for calculations
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load D = 00760 k/ft Tributary Width =
: Maximum Bending Stress Ratio =
Section used for this span
Mu Applied
Mn/ Omega Allowable
Load Combination
Location of maximum on span
1 Span # where maximum occurs
, Maximum Deflection
Max Downward Live Load Deflection
Max Upward Live Load Deflection
Live Load Deflection Ratio
Max Downward Total Deflection
Max Upward Total Deflection
Total Deflection Ratio
1 0 ft
0188 1
W10X22
12166k-ft
64870k-ft
+0
1 5 644ft
Span # 1
0 000 in
0 000 m
0 <360
0 642 in
0 000 in
588
Maximum Shear Stress Ratio =
Section used for this span
Vu Applied
Vn/Omega Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Support Reactions ( kips )
D L+Lr S
Support #1 ' 154
Support #2 1 54
0032
W10X22
1 5450 k
48960 k
+D
0000 ft
Span # 1
1
W
Overall MaximurrTDeflections' Unfactored Loads.
Load Combination Span Max Defl Location in Span Load Combination Location in Span
^ ^ 1 06419_ 15856
^Maximum Reflections fonLoaSjCombinatiohs Unfactored Loads-;0000
Load Combination Span Max Downward Defl Location in Span Max Upward Defl Location in Span
DOnly
Maximum'Reactions - Unfactored
06419 15856 0 0000 0 000
Note Only non zero reactions are listed
Load Combination Support Vertical Reaction
Overall MAXimum
Overall MAXimum
DOnly
DOnly
Support 1 (DOnly)
Support2 (DOnly)
Support 1
Support 2
1545
1545
1545
1545
0(0u
o
8
Q111_iS
l§
CM WI
~
D5) en
:
3
v5= A
o/
\
tQL