HomeMy WebLinkAbout2055 CORTE DEL NOGAL; ; CB081983; Permit11-07-2008 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No CB081983 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Reference # PC# Project Title 2055 CORTE DEL NOGAL CBAD ELEC 2130610800 Lot# INSTALL 6 LIGHT POLES & BASES Status Applied Entered By Plan Approved Issued Inspec* Area ISSUED 10/24/2008 JMA 11/07/2008 11/07/2008 Applicant MC3 CONSTULTANTS, INC STEE 5245 AVENIDA ENCINAS 92008 760 930 9966 Owner S D C CORTE L L C 7065 EL CAJON BLVD SAN DIEGO CA 92115 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees 0 0 0 0 $1000 $000 $000 $000 $000 $1000 $000 $000 $18000 $000 TOTAL PERMIT FEES $200 00 Total Fees $200 00 Total Payments To Date $200 00 Balance Due $000 BUJLDING PLAN5 Jl_INSTORAGF. ATTACHED Inspector Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" W fees, dedications, reservations or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired City of Carlsbad 1—1635 Faraday Ave , Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www carlsbadca gov Building Permit Application Plan Check No CJ&O? Est. Value Plan Ck. Deposit Date JOB ADDRESS CT/PROJECT LOTS # OF UNITS DESCRIPTION OF WORK Include Square Feet of Affected Area(s) ± (£") If^T # BEDROOMS SUITE#/SPACE#/UNIT# # BATHROOMS TENANT BUSINESS NAME /A6 CONSTR TYPE OCC GROUP i \l~ FT EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YESD # _NOD AIR CONDITIONING YES D NOD FIRE SPRINKLERS YES D NOD CONTACT NAME (If Different Font Applicant)APPLICANT NAME ADDRESS ADDRESS PROPERTY OWNER NAME •CONTRACTOR BUS NAMEA MC, ADDRESS ADDRESS CITY STATE ZIP CITY STATE CA ZIP PHONE FAX PHONE -1 2&-1 FAX -FT ?v EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC #cuss CITY BUS LIC# (Sec. 70315 Business and Professions Code An/ City or County which requires a permit to construct alter, improve, demolish or repair any structure prior to us issuance also requires the applicant for such permit to Tile a signed statement that he is licensed pursuant to the provisions of the Contractor s license Law {Chapter 9 commending with Section 7000 of Division ! of the Business and Professions Codi>} or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 70! 15 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {1500}) V Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations CU I have and will maintain a certificate of consent to self Insure for workers compensation as provided by Section 3700 of the Laboi Code, for the performance of the work for which this permit is issued 01 J have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers compensation ijisurajice camerjndj •Xnumberare Insurance Co f/Mr^EwE^-S /A^fctA-4/tf Jr" Policy No U> g'3Ol? M,Q»W6» Exp.ration Date 7 ^ This section need not be completed if the permit is for one hundred dollars ($100) or less L7J Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (& 100,000), in Addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees £$ CONTRACTOR SIGNATURE *>&>^[L£_J-DATE 10 civil Tines up 10 one n 1&/&1/6 / hereby affirm that I am exempt from Contractors License Law for the following reason n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner builder will have the burden of proving lhat he did not build or improve for the purpose of sale) D I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Prolessions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) O I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D Yes D No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work ''include name / address / phone / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) ^PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan/acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley Tanner Hazardous Substance Account Act7 d Yes a No / Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' a Yes HNo Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' d Yes H No EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stones in height 180 days from the date of such permit or if the building or work authonzed by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT'S SIGNATURE \/'£-£x — (j-~*LS DATE City of Carlsbad Bldg Inspection Request For 05/06/2009 Permit* CB081983 Title INSTALL 6 LIGHT POLES & BASES Description Inspector Assignment JM 2055 CORTE DEL NOGAL Lot 0 Type ELEC Sub Type Job Address Suite Location OWNER S D C CORTE L L C Owner FILSINGER STEVE C Remarks SHAWN SAID YOU SIGNED OFF THIS PERMIT Phone 7609309966 Inspector Total Time Requested By SHAWN Entered By CHRISTINE CD Description 39 Final Electrical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments 12/03/2008 39 Final Electrical CO JM WORK NOT COMPLETE City of Carlsbad Building Department 1635 Faraday Avenue, Carlsbad, CA 92008 Phone 760-602-7541 / Fax 760-602-8558 sboro@ci.carlsbad.ca.us Plan Check Comments, too7 To From Steve Borossay PE Fax Pages \ Phone Date Re Address.Cor-l- For Review Please Reply P/ease make corrections on the originals and run TWO new prints Red marks on plans are part of this comment list Please return red marked set also 0 w- J OUT~<<7 P City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST DATE - BUILDING ADDRESS PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER PLANCHECK NO CB *? -6> f r ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements EST VALUE DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date By FOR OFFICIAL USE ONLY /ENGIhTEERING-f UTHORIZATION TO ISSUE BUILDING PERMIT ->T7A ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Neighborhood Improvement Agreement D Grading Permit Application D 'Grading Submittal Checklist D Right-of-Way Permit Application £] Right-of-Way Permit Submittal Checklist and Information Sheet Q Storm water Applicability Checklist Name ENGINEERING DEPT CONTACT PERSON JOANNE JUCHNIEWICZ City of Carlsbad Address 1635 Faraday Avenue, Carlsbad, CA 92008 Phone (760) 602-2775 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract Carlsbad, CA 92OO£-7314 • (76O) 6O2-2720 • FAX (76O) 602*05102 BUILDING PLANCHECK CHECKLIST SITE PLAN DXA/(\ .-si 2ND 3RD O CD CD 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow F Right-of-Way Width & Adjacent Streets B Existing & Proposed Structures G Driveway widths C Existing Street Improvements H Existing or proposed sewer lateral D Property Lines I Existing or proposed water service E Easements J Existing or proposed irrigation service D Q D 2 Show on site plan A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service <s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards D D D 3 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION F BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE D O D 4a Project does not comply with the following Engineering Conditions of approval for Project No CU d CH 4b All conditions are in compliance Date DEDICATION REQUIREMENTS D D D 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Yz" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist foi the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS EH L~H 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F BUILDING PLANCHECK CKLST FORM doc 3RD BUILDING PLANCHECK CHECKLIST checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date CH CH CD 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $430 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows C] CD 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date D d D 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15 16010 of the Municipal Code CD CD CD 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial) This information must be included on the plans. CD CD CD 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date CD CD CD 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F BUILDING PLANCHECK CKIST FORM doc BUILDING PLANCHECK CHECKLIST .. ST 2ND 3RD CU d CD 7d No Grading Permit required D D D 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D D D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for D D D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7138, for assistance Industrial Waste permit accepted by Date n D D 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first D D D 10 a STORM WATER COMPLIANCE FORM Q Requires PSWP (project storm water permit) # Q Tier I/Tier II ^Requires SWPPP) - Please complete attached forms Q Exempt - Please complete attached exemption form D D D 11 FEES Q Required fees are attached Q No fees required F \BUILDING PLANCHECK CKLST FORM doc ,ST NO2 D 5RD D D BUILDING PLANCHECK CHECKLIST WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) 12b Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA1+00 Install 2" service and O;5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection F BUILDING PLANCHECK CKLCT FORM doc BUILDING PLANCHECK CHECKLIST ..ST 2ND 3RD 3 In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future 12c Irrigation Use (where recycled water Is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this D 13 Additional Comments: C dr o uP7tL- F BUILDING PLANCHECK CKLST FORM doc y From: Glen Van Peski To: Joanne Juchniewicz CC: Mike Peterson Date: 11/05/2008 6 28 AM Subject: Corte de Nogal parking Joanne - I don't know if you heard, but Pete went out there, and all that parking lot is in So, it seems like we need a stormwater questionnaire, and they will need to do a SWMP since they will be a priority project It would be interesting to go back to the TI and find out what they showed for the parking Let me know if you want to chat on this --Glen •3 CIS Map Listing - Microsoft Internet Explorer provided by City of Carlsbad Refresh Map ounaary HMP Preserve Areas Openspace LCPA Boundary C LCPA Zoning C Zoning C Vegetation Air Photo 03/08 Air Photo 03/07 Air Photo 04/05 Air Photo 01/03 Air Photo 08/01 Encinitas 08/01 Oceanside 08/01 Refresh MapM jp cnutod by CaridMcMaSC I-I File Edit View Image Go To Favorites Helpi -; ' * *_ Carlsbad^DOCMAN - Microsoft Internet Explorer provided by City ... HE! E3 .H..'r.} Search '•'•"','FavoritesV-.j \ Address ;gj http //docweb/idmws/DocView asp?id=003830435&Library=Carlsbad^DOCMAN ^ISA-C^V (11/07/2008) Joanne Juchniewicz - 2055 Corte Del Nogal '"' Page 1 From: Joanne Juchniewicz To: Peter Dreibelbis CC: Glen Van Peski, Mike Peterson Date: 11/07/2008 8 22 AM Subject: 2055 Corte Del Nogal Hey, Hey Pete, Per our conversation this morning, could you please hold the certificate of occupancy on the above address until they comply with Engineering's request for a BMP/LID plan for the expansion of the parking lot Glen is willing to release the current building permit for the parking lot lighting (CB081983) so they can continue with work Glen or I will let you know when they have compiled with engineering's request If you have any questions, you know where I am1 Thank you so very much, Jo PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 08-1983 DATE10/30/8 ADDRESS 2055 Cortte Del Nogal RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER PLANNER CS ENGINEER DATE 10/30/8 DATE II \AIIMIX\rni:vrER/PLA\MXII/hM;i\HERIM; APPROVALS Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Paseo Delicias • P O Box 2211 • Rancho Santa Fe, CA 92067 Telephone (858) 759-2434 • Fax (858) 759-8324 2- JOB_ SHEET NO^ CALCULATED BY_ CHECKED BY SCALE OF _DATE_ DATE LI6HTPOLE DETAIL Oct30081107a Diane Maple 760-930-9941 P2 Veri'y Bolt Ci'zle D/o Ana Anchor Bait Project/or Use Anchor Boll Tsmp/a'e Drill Holes In Pi/wood Use As A Locator For Anchor Bolts 081 ' Die Bait Circle \ For Use With HAPCO 4" Square Steel Catalog Poles. For Special Applications, Consult Your Representative. \jI (4) 3/4"-lONC Anchor Baits' 3o't WARNING 00 NOT INSTALL LIGHTING POLE5 WlTHCUT LUMIN«1RES grapco rm£ g j/2' Dig BC Template SCM.E FULL JUW 2/4/03 B36664 Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Paseo Dehcias • PO Box 2211 • Rancho Santa Fe, CA 92067 Telephone (858) 759-2434 • Fax (858) 759-8324 E-mail ranchosantafe@pvec coin PROJECT JOB # SHEET NO I OF CALCULATED BY CHECKED BY SCALE DATE .DATE CtffcTT QfiL 0 OK GLUH>4M B-CX7F DISK^J Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Paseo Delicias • P O Box 2211 • Rancho Santa Fe, CA 92067 Telephone (858) 759-2434 • Fax (858) 759-8324 SHEET NO L. CALCULATED BY_ CHECKED BY. SCALE OF _DATE_ DATE ff 3 2-»3 TIES C IN TOP 5" ' / / ^s / / / 'x1 * / / ', / / / V«^a A 3" — 1 . M ^ATI!iiMnHn —.. t-~ i-- L , L4MP POST t .sy BA&E PER PL.4N / . 3/4" dla. 4NCHOR / .X x11"LON&x3" '! 1II ' "jj-f "~t -4 J - — 24° dta / PER PLAN/ / ' ' // / / / '•///<< m; 24" dla PIER •3 TIES • B" e»jc ^3" LIGMTPOLE DETAIL L_ Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Pasco Delicias • P 0 Box 2211 • Rancho Santa Fe, CA 92067 Telephone (858) 759-2434 • Fax (858) 759-8324 JOB O.M.QM SHEET NO 1) OF CALCULATED BY fee. DATE b-l > CHECKED BY DATE SCALE L\&wr feMB-MVJ USE. ZV" ft Palos Verdes Engineering PO Box2211 Rancho Santa Fe, CA 92067 (858) 759-3434 (858) 759-8324 (Fax) Title Dsgnr. Description Scope. Job* Date 704AM, 13 MAR 07 Rev SSWtaKW0606946 VsrSSO 1 Dac-2003 Win32 (c)1963-2009 ENERCALC Enfltnorlng Software Pole Embedment in Soil Page 1 Description LightPole Footing General Information Allow Passive Max Passive Load duration factor Pole Is Circular Diameter Restrained @ Surface 1 Summary | Moments @ Surface Point load Distributed load With Surface Restraint Req'd Depth Orpcefira ffa RAQf*r (C33UIO \^f P&9& Actual Allowable Surface Restraint Force 200 00 pcf 3,000 00 psf 1 330 24 000 In ooo n-# 6,760 00 3 B7s ft"> y 1,005 44 psf 1,005 44 psf 3,461 83 Ibs Code Ref 1 997 UBC 1806 8 2 1 , Applied Loads Point Load distance from base Distributed Load distance to top distance to bottom Total Moment Total Lateral HsV 2003 IBC 1 805 7 2. 2003 NFPA 5000 36 4 3 jj 0 00 Ibs 0000ft BO 00 #/ft 13 000 ft 0000ft 6.760 00 ft-# 1,040 00 Ibs °9 1 1 Z: 0 ISTAO 05 to o w m 5*1(f) til e° m C3 pj bO \N§ NJo