Loading...
HomeMy WebLinkAbout2061 ARENAL RD; MP; CB102556; Permit12-28-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No: CB102556 Building Inspection Request Line (760) 602-2725 Job Address: 2061 ARENAL RD CBAD St: MP Permit Type: ELEC Status: ISSUED Parcel No: 0000000000 Lot#: 0 Applied: 12/28/2010 Entered By: KG Reference #: Plan Approved: 12/28/2010 PC#; Issued: 12/28/2010 Project Title: LA COSTA RESORT/REMOVE AND Inspect Area: REPLACE METER PED. 100 AMP/LOCATED ON GOLF COURSE Applicant: DRINKWARD ELECTRIC INC P.O. BOX 461535 ESCONDIDO CA 92046 760-400-6120 Owner: Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees 100 0 0 0 $10.00 $25.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 TOTAL PERMIT FEES $35.00 Total Fees:$35.00 Total Payments To Date:$35.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date: / ' 5~' fl Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions, If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. t * X^S CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717/2718/2719 Fax 760-602-8558 www.carlsbadca.g6v Plan Check No. Est. Value Plan Ck. Deposit SWPPP JOF -"\—B CT/PROJECTT PHASES #OFUNITS |# BEDROOMS SUITE#/SPACE#/UNIT# # BATHROOMS TENANT BUSINESS NAME •CONSTR.TVPE OCC.fiROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YES|~K AIR CONDITIONING YES | | NO FIRE SPRINKLERS YESI I NC CONT E (If APPLICANT NAME ADDRESS ADDRESS CITY ZIP CITY STATE ZIP PROPERTY OWN CONTRACTOR BUS. NAME ADDRESS ADDRESS ?6 STATI ZIP CITY STATECA* PHONE FAX FAX EMAIL ARCH/DESIGNER NAME/ ADDRESS EMAIL STATE LIC. # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: / hereby affirm under penalty of perjury ore of the following declarations: LJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. J^fl have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensationJnsuranpe carrier and policy number are: Insurance Co ^J/@4T£& Y A/tpJJfffvaL .^rtH^- C-lJ, Policy No. tfpQfiOG&Z&fffflA f ^^ Expiration Date Y///*7/ // This section need not be completed if the permit is for one hundred dollars ($100) or less. I I Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' -Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as proyMed for in Section 3706 of the Labor code, interest and attorney's fees. , >£$" CONTRACTOR SIGNATURE /^L I/ /.//-„_ ^/ QAGENT DATE /^/2^~7/Z^l Q I hereby affirm that I am exempt from Contractor's License Law for the following reason: | | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I | I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). I I I am exempt under Section : Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I JYes I [NO 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone /contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): .^PROPERTY OWNER SIGNATURE AGENT DATE Is the applicant or future building occupant required to submit a business clan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I I Yes I iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air Quality management district? L|Yes [~1 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I JYes I JNo EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby auttiorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAIDCITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if tie building or wortouthorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ^APPLICANT'S SIGNATURE / ' ff.. V L. ~ L, J DATE City of Carlsbad Bldg Inspection Request For: 01/04/2011 Permit# CB102556 Title: LA COSTA RESORT/REMOVE AND Inspector Assignment: Description: REPLACE METER RED. 100 AMP/LOCATED ON GOLF COURSE WITH ARENAL RD ACCESS Sub Type:Type: ELEC Job Address: 2061 ARENAL RD Suite: MP Lot: 0 Location: APPLICANT DRINKWARD ELECTRIC INC Owner: Remarks: Phone: 951323365 Inspector: < Total Time: CD Description 33 Service Change/Upgrade Act Comments Requested By: MIKE Entered By: JANEAN Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments Check a License - Contractors State License Board Page 1 of2 Department of Consumer *"*>£&* Contractors License BoardjSEr Contractor's License Detail - License # 858629 earn DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. ••» CSLB complaint disclosure is restricted by law (B&P 7124.6) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. * Per B&P 7071.17 , only construction related civil judgments reported to the CSLB are disclosed. ••» Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. •* Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number Business Information 858629 Extract Date: 12/28/2010 DRINKWARD ELECTRIC INC PO BOX 461 535 ESCONDIDO, CA 92046-1535 __ Corporation^ JsjtueJDate Reissue Date Expire Date License Status Additional Status: Classifications: Bonding: Workers' Compensation: Miscellaneous Information: _05/27/2008_ ^05/31/2012^ This license is current and active. All information below should be reviewed. CLASS DESCRIPTION J SEMEBAL...BUILDING CONTRACTOR C10 ELECTRICAL CONTRACTOR'S BOND This license filed Contractor's Bond number SC6081503 in the amount of $12,500 with the bonding company AMER|CAN£QNTR&CTORmNDEMNITXCQMPANY. Effective Date: 03/02/2009 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) DRINKWARD CHRISTOPHER SCOTT certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 05/27/2008 This license has workers compensation insurance with the EVEREST NATIONAL INSURANCE COMPANY Policy Number: 76000062861 01 Effective Date: 11/17/2010 Expire Date: 11/17/2011 DATE 05/27/2008 DESCRIPTION LICENSE REISSUED TO ANOTHER ENTITY Personnel listed'on this license (current or disassociated) are listed on other licenses. https://www2.cslb.ca.gov/OnlineServices/CheckLicenseII/LicenseDetail.aspx?LicNum=8... 12/28/2010 sr* If« l! < D. A a,. it Ifa -** Si ft *? r.K* ^ If I -•*• 1_T3 CD COMMERCIAL METER PEDESTALS SERVICE 0-200 AMPS (FOR ALTERNATE TO PEDESTALS, SEE NOTE 11)11" MIN. 12" MAX. Hinge Demand Reset Cover with Polycarbonate Viewing Window NOTE; The pull section for utility service may be located on the front, back or side of a meter pedestal, depending on the manufacturer. 36" MIN 75" MAX FRONT VIEW (SINGLE) 24" MIN 110-1/2" 48" MIN 44" MIN m fc> Customer Section |Single-Phase is'> |acceptable forgf' Idual pedestals! ' NN % ^ FIG. 3 u FRONT VIEW (DUAL) Enclosing Cover See Note 4 Meter Section Barrier To Extend To Edge Of Test Block Barrier Protective Metallic Barrier See Note 6 Working space from face of panel req'd. „ Meter Socket Test Bypass ""Support 6" MAX Landing Lugs And Factory Installed Conductors See Note 2 Pull section and cover See Notes and 2 36" MIN. working space req d 17" MIN. SIDE VIEW (TYPICAL) Hinged Cover with Attached Sides. See Note 4 for fixed top and sides Hinged Demand Reset Cover Handle — 3/4"MIN 17"MIN — W FIG. 4 UTILITY TERMINATION SECTION TABLE 1 - MIN. DIMENSIONS SERVICE 1 PHASE 3PHASE W 10-1/2" 12-1/2" See page 692.1 for Notes and See page 692.2 Foundation Details j © 1998-2007 San Diego Gas & Electric Company. AB rights reserved. Removal of thta copyright notice wlthoul permission Is not permitted under law. | Indicates Latest Revision | | Completely Revised | | New Page |Information Removed REVISION DATE r2-13-06 BRB SDG&E SERVICE STANDARDS 8e GUIDE ELECTRIC SERVICE AND METERING EQUIPMENT COMMERCIAL METER PEDESTALS 692