Loading...
HomeMy WebLinkAbout2065 CALETA CT; ; CB072452; Permit04-24-2008 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB072452 Building Inspection Request Line (760) 602-2725 2065 CALETA CT CBAD RESDNTL 2151100900 $14869400 0 0 Sub Type RAD Lot# 0 Construction Type VN Reference # Structure Type Bathrooms 0 HACK RES- 818 SF ADDITION & 389 SF REMODL 55 SF TRELLIS 63 SF DECK EXTEND Status Aoplied Entered By Plan Approved issued Inspec* Area Ong PC# Plan Gneck# ISSUED 09/21/2007 LSM 04/24/2008 04/24/2008 Applicant JERRY SELAH STE 300 8706 LAKE ASHMERE DR SAN DIEGO 92119 6198571488 Owner HACK FAMILY TRUST 03-11 38 2065 CALETA CT CARLSBAD CA 92009 Building Permit Add I Building Permit Fee Plan Check Add I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $760 89 Meter Size $0 00 Add'l Reel Water Con Fee $494 58 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1487 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic Impact Fee (43055il) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TO1AL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee $0 00 Housing Credit Fee Master Drainage Fee $0 00 Sewer Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $1 270 34 Total Fees $1,270 34 Total Payments To Date $1,27034 Balance Due $000 MG PLANS STORAGE ATTACHFn Inspector FINAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations o other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/axactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required •< formation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will ba< any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water dnd sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this projf J NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations his previously otherwise expired City of Carlsbad 1635 Faraday Ave Carlsbad CA 92008 760 602 2717 / 2718 / 2719 Fax 7606028558 Building Permit Application Plan Check No (L& 6 "7«2W gs&tfl /Z&nod&l'Ws, 63$ded;eK-l?h sin AIR CONDITIONING I FIRE SPRINKLERSEXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE ' YESV# _ NOD FIRE SPRINKLERS YES D NCrQ(,' CONTACTNAMt (If Different Fom Applicant) <\DDRESS CITY \&K f&M\ i STATE ZIP FAX APPLICANT NAME ADDRESS CITY PHONE EMAIL STATE ZIP 1 JFAX PROPERTY OWNER NAME ADDRESS CITY PHONE i%u HA^-CONTRACTOR BUS NAME ADDRESS STATI FAX ZIP CITY STATE ZIP PHONE FAX ! ARCH/DESIGNER NAME ft ADDRESS STATE LIC # EMAIL STATETTC"*™CITY BUS LIC # Kef 70315 Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he islicensed pursuant to the provisions of the Contractor s License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}) Workers Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued LT! I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers compensation insurance carrier and policy number are Insurance Co Policy No Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less O Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Lavs of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees J£*> CONTRACTOR SIGNATURE DATE i-^• I harohttI hereby affirm that I am exempt from Contractors License Law for the following reason I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) ^f I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such piojects with conlractor(s) licensed pursuant to the Contractors License Law) Cl I am exempt under Section ... Business and Professions Code for this reason / 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O Yes TSvto 2 Hfiavp/ have not) signed an application for a building permit for the proposed work i 3 I nave contracted with the following person (firm) to provide the proposed construction (include name address / phone / contra( tors license number) "iff *?£ * 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major wort (include name / address / phone / contractors license number) 5 I wi'l provide some of the work but I have contracted (hired) the following persons to provide the work md'cated (include name / address /phone / type of work) fr L~~^^i2*- ^PROPERTY OWNER SIGNATURE V DATE Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' O Yes Cl No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 d Yes D No Is the facility to be constructed within 1 000 feet of the outer boundary of a school site7 D Yes D No IF ANY OF THE ANSWERS ARE YES EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) , Lenders Name Lenders Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agrre to comply with all City ordinances and State laws relating to building construction I hereby authonze representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permrt is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height 180 days from re date of such permit onf the building or work authorize^) by such jfornit is suspended or abandoned at any time after the work is commenced for a penod of 180 days (Section 106 4 4 Uniform Building Code) ^ APPLICANTS SIGNATURE DATE Inspection List Permit* CB072452 Type RESDNTL RAD Date Inspection Item 08/27/2009 89 08/27/2009 89 03/24/2009 17 03/24/2009 18 03/11/2009 14 03/11/2009 16 03/05/2009 34 03/05/2009 39 03/04/2009 17 02/24/2009 13 02/24/2009 14 02/24/2009 34 02/24/2009 44 02/17/200924 02/17/200927 02/04/2009 15 12/12/2008 11 12/12/2008 14 11/12/2008 11 10/31/2008 11 Final Combo Final Combo Interior Lath/Drywall Exterior Lath/Drywall Frame/Steel/Bolting/Weldm Insulation Rough Electric Final Electrical Interior Lath/Drywall Shear Panels/HD's Frame/Steel/Bolting/Weldm Rough Electric Rough/Ducts/Dampers Rough/Topout Shower Pan/Roman Tubs Roof/Reroof Ftg/Foundation/Piers Frame/Steel/Bolting/Weldm Ftg/Foundation/Piers Ftg/Foundation/Piers Inspector Act PC - PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC PC AP Rl AP AP AP AP CO PA AP AP CO AP AP AP AP AP we PA AP PA HACK RES- 818 SF ADDITION & 389 SF REMODL,55 SF TRELLIS.63 SF DE Comments AM PLEASE 10-12 SMOKE DET @ HIGH PT CEILING EMR SHOWERS OK TO WRAP DRAFT STOPS CHECK AT INSUL OK TO DRY IN SUBFLOORSO SIDE INT FTG REAR COL PADS LIVING RM 10/30/2008 11 Ftg/Foundation/Piers PC CO FTG STEEL NOT PER PLAN Thursday August 27 2009 Page 1 of 1 City of Carlsbad Bldg Inspection Request For 08/27/2009 Permit* CB072452 Title HACK RES-818 SF ADDITIONS Description 389 SF REMODL,55 SF TRELLIS.63 SF DECK EXTEND Sub Type RAD Inspector Assignment PC 2065 CALETA CT Lot Type RESDNTL Job Address Suite Location OWNER HACK FAMILY TRUST 03-11-98 Owner HACK FAMILY TRUST 03-11-98 Remarks AM PLEASE 10-12 Phone 6195239883 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By ED Entered By JANEAN omments Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date 03/24/2009 03/24/2009 03/11/2009 03/11/2009 03/05/2009 03/05/2009 03/04/2009 02/24/2009 02/24/2009 02/24/2009 02/24/2009 02/17/2009 02/17/2009 Description 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 14 Frame/Steel/Bolting/Weldmg 16 Insulation 34 Rough Electric 39 Final Electrical 17 Interior Lath/Drywall 13 Shear Panels/HDs 14 Frame/Steel/Boltmg/Welding 34 Rough Electric 44 Rough/Ducts/Dampers 24 Rough/Topout 27 Shower Pan/Roman Tubs Act AP AP AP AP CO PA AP AP CO AP AP AP AP Insp PC PC PC PC PC PC PC PC PC PC PC PC PC Comments SMOKE DET @ HIGH PT CEILING EMR SHOWERS OK TO WRAP DRAFT STOPS CHECK AT INSUL "A Quality Assurance Firm" TESTING SERVICES & INSPECTION INC. 3030 Main Street San Diego CA 92113 (619) 234-99O4 (619) 234-4931 Fax VISUAL INSPECTION REPORT Project Name HACK RESIDENCE Proicct Address 2U6S CALKTA COURT Permit Number CB07 2452 Architect SELAH AMCHITKCTURE Engineer MIKE SURPRENANT File Number N/A General Contraetor BRASSEUR CONSTRUC PION Job Nurrber N/A Contractor Doing Reported BRASSEUR CONSTRUCTION Other N/A Lab Receiving & Testing Conslr Mai I Samples N/A Other N/A INSPECTION MATL SAMPLING QIV MAT'L DESCRIPTION INSPECTION CHECK LIST Field Shop Concrete Cylinders RcinlbrciiiL Steel Plan/Specs S3 SD4 Concrete Mortar Samples Cone Mix/PSl Clearances SlrucliiKil Steel Grout Samples Cone Mix/PSl Positions Masonry Masonry Prisms All 1 lire-id Bolts S/8 7/8'Sizes FircproolMij,Masonry Block F.xp iiision Anchors Laps Pile Dnvinj,Rciiilorciiij, Steel Mon-irT)pe/PSI Consolidation Roofing..Fiicproofiiij,H S Rolls Torque Applied Specialty Asphalt Conuelc Illectiode Tension Applied Soils EiiLjucer RoofiiiL Steel Epoxy SIMPSON 1772 Boll Pull Out Steel Firepioot Drilled Holes PER PLAN Pie stress Concrete Hil.li Strength Bolls Units Block Corrective Action Epoxy Boll & DoweM_Other Unit Buck OSI-ll'D Other Met il Deck OSA Other Rcmf Tendons Corrections Complete Mechanical Other Other Electrical Other F.poxy Batch Plant Other Othei Inspection Date 11-18-08 EPOXY BOLT INSTALLATION VERIFIED HOLE SIZE AND DEPTH OBSERVED HOLE CLEAN OUT WITH COMPRESSED AIR AND BRUSH MONITORED EPOXY BOLT INSTALLAT ION PROCEDURES IN THE FOLLOWING LOCATIONS • 4- 7/8" ALL THREAD BOLTS FOR HARDY FRAMES AT GARAGE FRONT • 2- 7/8" ALL THREAD BOLTS FOR HD'S • 65- ALL THREAD BOLTS INTO EXISTING FOOTING EXTERIOR WALLS AND BACK INTERIOR WALL AT GARAGE EPOXY-SIMPSON STRONG TIE SET 22 ICC 1772 EXPIRES 06-30-2010 EMBED AS PER APPROVED PLAN SHEETS S3 AND SD 4 CERTIFICATION OF COMPLIANCE All of the reported woik unless otherwise noted complies with approved plans specifications and applicable sections ofthe building codes This report only covers the locations ol the uoik inspected -ind does not constitute uinjiiccniij, opinion or project control INSPECTOR NAME STANLEY I. SCHLACLR CER III ICAI E NUMBER 4S5 NOTE Inspections based on a 4-hour ininiimim, actual tune 'iftci 4 houis. 2 hour show up minimum for job cancel!:! double 11mo on Sunday SUBMITTED TO CITY OP CARLSBAD/ BRASSEUR CONSTRUCTION Overtime effective on Saturdays EsGil Corporation In Partnership with government for Quitting Safety DATE 4/14/08 JURISDICTION Carlsbad PLAN CHECK NO 072452 SET III PROJECT ADDRESS 2065 Caleta Ct PROJECT NAME Hack SFD Addition and Remodel APPLICANT a PLAN REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed 2<] REMARKS (T)) Applicant states that Will Foss has waived the soil report requirement for this project •& The red-bubbled changes on sheet A6 need to be made on the III set held at the City wj^be III set received by Esgil had a duplicate of sheet A9 I have rolled it in the plans incasejt is missing from the set held at the City /^f Please place City soils stamp on the\plan\^ Thank you ^ ^\ By Tamara Fischer v \WWL' Enclosures Esgil Corporation * n GA n MB n EJ n PC 4/7/08 9320 Chesapeake Drive, Suite 208 4 San Diego California 92123 + (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In Partnership with government for Viuifding Safety DATE 2/7/08 a APPLICANT a JURIS JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 072452 SET II PROJECT ADDRESS 2O65 Caleta Ct PROJECT NAME Hack SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ]X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Jerry Selah 8706 Lake Ashmere Dr, Suite 300, San Diego, CA 92119 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Jerry Selah Telephone # 619 857-1488 Date contacted Z{1 /Of(by/£$) Fax # 619460-9226 Mail v Telephone Fax \/\r\ Person REMARKS By Tamara Fischer Enclosures Esgil Corporation D GA D MB D EJ D PC 1/31/08 9120 Chesapeake Drive Suite 208 ^ San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 Carlsbad 072452 2/7/08i Please make all corrections, as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete NOTE The items listed below are from the previous correction list These items have not been adequately addressed The numbers of the items are from the previous check list and may not necessarily be in sequence The notes in bold are current 2 Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations (California Business and Professions Code) Engineer's stamp and signature are needed on structural sheets Please note The SD sheets were missing from this submittal and H1 and H2 were missing from one of the sets I have only one set of the original plans, so I can't slip sheet them 5 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per below Please show locations on the plans Smoke detectors added at existing construction need only be battery powered Section 310 9 1 2 b) Centrally located in corridor or area giving access to sleeping rooms (Hallways or rooms outside all bedrooms and study) Hallway outside study 8 Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1 5 sq ft Section 1203 Master bath (4 5 sq ft required, 2 5 sq ft provided) Window A Height and width shown on window schedule does not match the 3' x3' size shown on the notes as required for the 45 sq ft of openable area m Master Bath Window B and C also conflict between notes and height and width shown Window A still called out at bath 4 still shows the old window A size and type Please clarify Carlsbad O72452 2/7/O8 1-0 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors New door 25 b) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers and in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and drain inlet Note on A-13 references window A at bath 2, it should be window B 12 Specify on the plans the following information for the roof materials, per Section 10633 a) ICC approval number, or equal This information was not found 14 Provide overflow dram or scupper for family room deck An overflow dram or scupper is now needed for new "light well" deck off bedroom 3 19 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 The City of Carlsbad requires a soil report for all 2 story additions If the soil report is more than 3 years old, an update letter must be provided All recommendations in the soil report need to be incorporated into the structural design and plans Soil report should include the following City to verify that soil report requirement has been waived a) In Seismic Zone 4, each site shall be assigned a near-source factor Identify this value in the soils report and on the plans Section 1629 4 2 b) Investigate the potential for seismically induced soil liquefaction and soil instability in Seismic Zones 3 and 4 This does not apply to detached, single-story dwellings Section 1804 5 c) Note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value Section 106 3 3 d) If the soils engineer recommends that he/she review the foundation excavations Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that i) The building pad was prepared in accordance with the soils report, ii) The utility trenches have been properly backfilled and compacted, and in) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report " e) Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (if required by the soil report) Carlsbad 072452 2/7/08 28 Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms Show basis for compliance UBC, Sec 31011 Per energy calculations existing unit is to be used to heat addition Please justify that it's size is large enough to heat the existing plus addition and specify the size of the unit in BTUs on the plans No sizing calculations found The 125,000 BTU unit seems small for this size house 29 Please provide a power and lighting plan for the addition and alterations to existing Further corrections may follow once this is received a) Show on the plans that countertop receptacle outlets comply with NEC Art 210-52(c), which reads as follows In kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces b) Show on the plans a wall receptacle adjacent to each lavatory in the bathroom NEC Art 210-52(d) Bath 4 and Master Bath. • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list? Please indicate • Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Tamara Fischer at Esgil Corporation Thank you EsGii Corporation In Partnership with government for fBu.itding Safety DATE 10/1/07 JURISDICTION Carlsbad PLAN CHECK NO 072452 SET I PROJECT ADDRESS 2065 Caleta Ct PROJECT NAME Hack SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes % The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Jerry Selah 8706 Lake Ashmere Dr, Suite 300, San Diego, CA 92119 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Jerry Selah Telephone # 619857-1488 Date contacted /^/^(by^f) Fax # 619460-9226 Mail Telephone,]/ FaxyXln Person REMARKS By Tamara Fischer Enclosures Esgil Corporation D GA D MB D EJ D PC 9/24/07 9320 Chesapeake Drive Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad 072452 10/1/07 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO 072452 JURISDICTION Carlsbad PROJECT ADDRESS 2065 Caleta Ct FLOOR AREA 818 sq ft SFD addition STORIES 2 389 sq ft mt remodel 55 sq ft new trellis 63 sq ft master deck extension HEIGHT 26 7' approx per UBC REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED 10/1/O7 DATE PLANS RECEIVED BY ESGIL CORPORATION 9/24/07 PLAN REVIEWER Tamara Fischer FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e, plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Carlsbad O72452 10/1/07 Important Notice Regarding the 2007 CBC If you are an architect, engineer, designer or contractor that performs work within the State of California, please be advised that a new building code will take effect on January 1, 2008 The new building code is based on the 2006 International Building Code (IBC) and it is significantly different than the Uniform Building Code (UBC) All plan review applications submitted after December 31. 2007 will be required to comply with the new code The 2007 CBC is currently available for purchase directly from the International Code Council, at www iccsafe org Please make all corrections, as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 2 Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations (California Business and Professions Code) 3 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbmg/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC Some of the code editions listed on sheet T-1 Project Data are incorrect 4 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section Carlsbad 072452 10/1/07 106 3 5 Please complete the attached form for epoxy anchors 5 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per below Please show locations on the plans Smoke detectors added at existing construction need only be battery powered Section 310 9 1 2 a) Inside each bedroom Study (which is considered a bedroom due to closet), bedroom"! b) Centrally located in corridor or area giving access to sleeping rooms (Hallways or rooms outside all bedrooms and study) c) When sleeping rooms are upstairs, at the upper level in close proximity to the stair 6 Sleeping rooms shall have a window, or exterior door for emergency escape Sill height shall not exceed 44" above the floor Windows must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools Section 3104 Bedrooms 7 Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203 3 Bedroom 3 (14 sq ft required) 8 Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1 5 sq ft Section 1203 Master bath (4 5 sq ft required, 2 5 sq ft provided) 9 Provide mechanical ventilation capable of providing five air changes per hour in bathrooms and water closet compartments if required openable windows are not provided Section 1203 3 Master bath water closet compartment 10 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors Doors 6 and 8 b) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers and in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and dram inlet Window B at master bath and bath 2 c) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface Existing window at living Carlsbad 072452 10/1/07 is now within 24" of new door 11 11 It appears deck off kitchen is less than 30" above grade Please specify this as guardrail detail does not comply with the requirements for decks more than 30" above grade (6" space at bottom of guardrail would need to be reduced to 4" in order to comply) Section 509 1 12 Specify on the plans the following information for the roof materials, per Section 10633 a) ICC approval number, or equal 13 Balconies and decks exposed to the weather and sealed underneath shall be sloped a minimum of 1/4 inch per foot for drainage Section 1402 3 14 Provide overflow drain or scupper for family room deck 15 Overflow drains shall terminate in an area where they will be readily visible and will not cause damage to the building If the roof dram terminates through a wall, the overflow dram shall terminate 12" minimum above the roof dram City Policy 84- 35 Please note on the plans 16 Garage requires one-hour fire protection (i e , 5/8" Type X drywall) on the garage side of walls and ceiling common to the dwelling Table 3-B, Section 302 4 17 All elements supporting floor above garage, including walls/beams/columns supporting floor joists, must have one-hour fire-resistive protection on the garage side Section 302 2 One hour protection at column requires protection from vehicle damage 18 Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling Section 302 4 Door 4 19 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 The City of Carlsbad requires a soil report for all 2 story additions If the soil report is more than 3 years old, an update letter must be provided All recommendations in the soil report need to be incorporated into the structural design and plans Soil report should include the following a) In Seismic Zone 4, each site shall be assigned a near-source factor Identify this value in the soils report and on the plans Section 1629 4 2 b) Investigate the potential for seismically induced soil liquefaction and soil instability in Seismic Zones 3 and 4 This does not apply to detached, single-story dwellings Section 1804 5 c) Note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value Section 106 3 3 d) If the soils engineer recommends that he/she review the foundation excavations Note on the foundation plan that "Prior to the contractor Carlsbad 072452 10/1/07 requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that i) The building pad was prepared in accordance with the soils report, n) The utility trenches have been properly backfilled and compacted, and in) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report" e) Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (if required by the soil report) 20 Detail 12/SD4 (new footing detail) is jeferenced at what appears to be an existing footing below wall between kitchen and foyer 21 Please specify size of new header over north living room window 22 Please specify size and spacing of new floor joists over dining area 23 There is a beam shown above the garage which is not identified on sheet S-4 24 Please clarify roof framing over Master Bath Please specify rafter size and spacing, ridge size and show how ridge is supported at west end 25 Please specify size and spacing of rafters ovei bedroom 2 26 Shear wall is not called out at line G upper per calculations 27 If trellis at entry is new, please provide member size and spacing, otherwise please identify on the plans as existing 28 Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms Show basis for compliance UBC, Sec 31011 Per energy calculations existing unit is to be used to heat addition Please justify that it's size is large enough to heat the existing plus addition and specify the size of the unit m BTUs on the plans 29 Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels If service is over 200 amps, submit single line diagram, panel schedule and load calculations 30 Please provide a power and lighting plan for the addition and alterations to existing Further corrections may follow once this is received 31 All bedroom branch circuits now require arc fault protection Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected " NEC Art Carlsbad 072452 10/1/07 210-12(b) 32 Package D used for energy compliance requires R-30 in ceilings Please show that all new rafters are minimum 10" deep to accommodate the R-30 33 The regulations require a properly completed and properly signed Form CF-1R (4 pages) to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design The signature of the designer or owner is missing from the CF-1R on the plans 34 Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement) a) In the kitchen at least one-half of the wattage rating of the fixtures must be high efficacy with non-high efficacy fixtures switched separately Note Approximately % of the fixtures will be required to be of the high efficacy variety b) In bathrooms, garages, laundry rooms, and utility rooms all fixtures must be high efficacy style or be controlled by a manually-on occupancy sensor c) All other rooms require any installed fixtures to be high efficacy or be controlled by a manually-on occupancy sensor or dimmer (Closets under 70 square feet are exempt) d) Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor Note Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts Regular incandescent, quartz halogen and halogen MR lamps do not comply 35 The replacement windows in an alternation must meet the U-factor and Solar Heat Gam Coefficient (SHGC) of Package "D" (Prescriptive requirement) Please specify this on the plans To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Carlsbad 072452 10/1/O7 • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list9 Please indicate • Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Tamara Fischer at Esgil Corporation Thank you HIKE SURPREIWIT & flSSO Fax,619-5:1-0CbH jan n m* iu. am Caoiabad O72452 10/1/07 of Carlsbad Department BmWNG DEPARTMENT NQTM3S QFJBTCOTimEMENT FOR BPBCIA1. INSPECTION Do Not RerjNJYE From Plans Flan awe*; NO. OT34S2 Jot A«W*«s or U&U D«criptjon 2O65 CaJeta Ct. i . g Owner fTliC- H£6f** _Add«sc * " You ate hereby notified that in addition to the taspedion of constcnction provided 19 (he Budding Department an approved Registoccd Special Inspector is tequiied to provide continuous inspection durm* tha performance of the phases of coflsrraction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the buildfag pennix. Special Joqpeccocs tovm^ a cuneni cemficaiitrn from die Ciry of San Diego, Los Angdes. or ICJBO ara approved as bpecjal Inspectors for tfte rype of ujusiructkm for which they arc certified TfeDWopferiblM^ ' " 'personnel of the Q'ty of Cttrlsh^ building department. Th« inspections by a Special Inspector are in addition to the inspections normally required by the Camay BuMijg Code. i he Special Inspector is not authuiml LO Suspect and approve any work other than that for which he/she is specifically as^gped to inspect, Tbe Special Inspector is not authonzed iD accept alternate matctula, structural changes, or any requests for plan changes, Tho Special TJOSpector is required to submit wnttcn repozts 10 the City of Carlsbad building department of aU wodc that he/she inspected ana approved. The ilaai rnspeaicm spprsvsJ will not be given urtul aJj special XpspectioB reports h^/ft been received and Approval by Ibe City of Carlsbad building department. Please auboni ihe narncs of the inspectors, who wiU pccfoiw the spccizJ inspoctSons on eaeh of the izenos jndioated on tha reverse side of this sheet. 099 698 dSOO 1I5S3 50«0t HIKE SURPRENRN1 & nbbU ha< t»3-5Ji-urjo Q TO d TViOi CadSbad 072452 1O/1/OT SPECIAL INSPECTION PROGRAM ADDRBSS OR UEQAL DESCRIPTION; PLAN CHECK NUMElEFh &S3z. OWNER'S NAME: I, as the owner, or agsrrt of the owner (contractors may /jpj: employ the special inspector), fisantty uini!, or the arctirted/engmeer o* record, will be responsible for anploying the special inspectors) as requirad by UrfttntrliijWng Code (UBC) Sieetion 1701.1 for the construction project located attfis^te li5te^atjo-^e/UBC Section 106.3 5, I, as the eogupccryarchitaet of record, certify that I b&VQ r^cparcd (he following special inspection UBC S«itioo 106.2J? for The constmetian project located at thft ititn listed 1. Lie* of work unqtiMng npecial inspaction: Soils Complian(»^norto Foundation Inspection Structure? Concrete Over 2500 Pel PrastresscO concrete Structural Masonry Designer Specified . High Stranflth Bolting on/EpoExy Anchors Sprayed-Dn G Other a, Nfime(s) or indtvitdual(s(> or tfrmfe) responalblo for tilie spscial inspections fistedabove; B. C. 3, Oldies of me special inspectors far the worK ffetod above: A. SVfr 5^ Das ase SO 01 iOO?;-30-K)0 Carlsbad 072452 10/1/07 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Tamara Fischer BUILDING ADDRESS 2065 Caleta Ct PLAN CHECK NO 072452 DATE 10/1/07 BUILDING OCCUPANCY R3 TYPE OF CONSTRUCTION Ul BUILDING PORTION SFD Addition Interior Remodel New trellis master deck ext Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 818 389 55 63 cb Valuation Multiplier 121 94 121 94 887 1441 By Ordinance Reg Mod - VALUE ($) 99,747 47,435 488 908 148,577 $760 89 Plan Check Fee by Ordinance Type of Review _l I Repetitive Fee Repeats Complete Review D Other ,—| Hourly Structural Only Hour* Esgil Plan Review Fee $494 58 $42610 Comments Sheet 1 of 1 macvalue doc DATE BUILDING ADDRESS PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST PLANCHECK NO CB 67 - //6 -EST VALUE ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review Only the applicable sheets have been sent By By By Date Date Date By ^X ^X FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Neighborhood Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist1-1 and Information Sheet ENGINEERING DEPT CONTACT PERSON Name KATHLEEN M FARMER City of Carlsbad Address 1635 Faraday Avenue Carlsbad CA 92008 Phone (760) 602-2741 NOTE If there are retaining walls associated with your project, please check with the Building Department if these walls need to be pulled by separate RETAINING WALL PERMIT A-4 , CA 92OO|8-7314 • (760) 6O2-2720 • FAX (76O) BUILDING PLANCHECK CHECKLIST ,RD SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A'"' North Arrow ' B/Existmg & Proposed Structures /6 Existing Street Improvements D-^Property Lines (show all dimensions) E Easements FXRight-of-Way Width & Adjacent Streets G/- Driveway widths Existing or proposed sewer lateral Existing or proposed water service Existing or proposed irrigation service D D D 2 Show on site plan A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF Example Tenant Improvement for 3500 SF of warehouse to 3500 SF of office F \Fflrnief\K.jitiy\MASTLRS\Building Plancheck Cklst Form (Generic) doc BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE CH CH O 4a Project does not comply with the following Engineering Conditions of approval for Project No 4b All conditions are in compliance Date DEDICATION REQUIREMENTS 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Vz x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS EH d 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \Farmer\KATHY\MASTERS\BuiMing Planctieck Cklst Form (Generic) doc .. ST BUILDING PLANCHECK CHECKLIST checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $ 430 00 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows D D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date CH EH d 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code d CD d 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill import, export and remedial) This information must be included on the plans [U CH CH 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date D 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F \FARMER\KATHY\MASTERS\Building Plancheck Cklsl Forni (Generic) doc BUILDING PLANCHECK CHECKLIST .. ST 2ND 3RD G G G 7d No Grading Permit required G D D 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D D D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for D D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date NPDES PERMIT G 10a Storm Water Requirements Applicability Checklist Completed G 10b Priority Determination and compliance D Priority Project D Subject to Standard Permanent Storm Water BMP's D Exempt -^ G D 11 D ^Required fees are attached No fees required WATER METER REVIEW G 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service F \FamiertKATHY\MASTERS\Building Plancheck CkSt Fom (Generic) doc , ST -.NO •>RD n n BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" service and 5 meter (estimated 100 gpm) 2 If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection 3 In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water '- \Farrntr\Kyshy\MAS1 EHS\Buiiding Plaricrieck Cklsi Form (Generic) doc 1ST 2ND 3RD BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this ODD 13 Additional Comments F>FaniiertKalhy\MASTERS\auiuiiisPI«nclMdiCkJaI Form (Generic) doc D D ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal Address Bldg Permit No Prepared by Date Checked by Date EDU CALCULATIONS List types and square footages for all uses Types of Use Sq Ft /Units Types of Use Sq Ft /Units APT CALCULATIONS List types and square footages for all uses Types of Use Sq Ft /Units Types of Use Sq Ft /Units EDU's EDU's ADT's ADT's FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1 PARK IN LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS = $ D 2 TRAFFIC IMPACT FEE ADT s/UNITS D 3 BRIDGE AND THOROl ADT's/UNITS D 4 FACILITIES MANAGED UNIT/SO FT D 5 SEWER FEE EDU s FEE/ADT = $ JGHFARE FEE yiENT FEE (DIST X ZONE X #1 DIST #2 FEE/ADT FEE/SO FT /UNIT DIST #3 ) = $ = $ BENEFIT AREA EDU's FEE/EDU FEE/EDU D 6 SEWER LATERAL ($2 500) D 7 DRAINAGE FEES PLDA_ ACRES = $_ = $_ = $ HIGH /LOW FEE/AC = $ D 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION Word\Docs\Mlsforms\Fee Calculation Worksheet 1 Of 2 3 d 5 a s DD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CBO~1~\ Planner Address hns Sexton Phone (760) 602-4624 Type of Project & Use Zoning f< / General Plan CFD (In/out) #_Date of participation Net Project Density DU/AC Facilities Management Zone _ Remaining net dev acres. Circle One Legend , Environmental Review Required* DATE OF COMPLETION (For non-residential development Type of land used created by this permit ) m Incomplete - Needs your action YES NO I/ TYPE Item Complete (Q Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO V TYPE DATE OTHER RELATED CASES Compliance with conditions or approval? If not, state conditions which require action Conditions of Approval n Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO i/_ CA Coastal Commission Authority? YES NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Dnve, Suite 103, San Diego CA 92108-4402, (619)767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed? YES NO. If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Incluslonary Housing Fee required YES NO v (Effective date of Inclusionary Housing Ordinance - May 21, 1993) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan Q O Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number Ira n HDD E/D D ETJD BTID Policy 44 - Neighborhood Architectural^Oesign Guidelines 1 Applicability YES NO ^ 2 Project complies YES NO_ Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope 2 Accessory structure Front Interior Side Street Side Rear Structure separation 3 Lot Coverage 4 Height 5 Parking Sf Required $O ' Reauired fi ' fe Required Reauired / 1 ' Required setbacks Reauired Reauired S' Reauired S Reauired /^ Reauired/ Reauired "^ 7 0 /o _ . •*£ "^2.f^\ iReauired iD( ) )aces Reauired f?~- Shown SO ' Shown €> ' Q? Shown Shown / ~> ' Shown Shown Shown / Shown / Shown y Shown^^ Shown ^ rO ?• Shown 0^2) ' ft Shown ^ — (breakdown by uses for commercial and industnal projects required) Residential Guest Spaces Required Shown Additional Comments PJ 9QA.9 dJ^JTUJ 1/1 £VLJ~ I JiQtA u &]L^ •f1 &PIUIJ&9. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \AOMIN\COUNTER\BldgPlnchkRevChklat Rev 3/06 GS> SELAH ARCHITECTURE & ASSOCIATES March 12, 2008 (Revision, Apnl 17, 2008 per City request) Mr Will Foss, Planning City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, Ca 92008 Re Soils Report for Hack Residence, 2065 Caleta Ct Plan Check # 072452 Dear Mr Foss, This correspondence is in reference to plan check item # 19, by EsGill Corporation, dated 2/7/08, regarding the need for a Soils Report for the above referenced project As discussed with you on 2/26/08 in a phone conversation, you would consider waiving the need for a Soils Report because the new area of construction for the new foundation is only 280 s f The residence is to be constructed utilizing primarily wood-frame construction Roof framing to consist of conventional stick-frame, and the foundation system to consist of a combtnatron of raised wood floor and concrete slab-on-grade with deepened perimeter footings The same foundation system is to be employed as the existing foundation system The soils, from my visual observation do not appear to be expansive in the area of the new construction Therefore, the foundation design in concurrence with the structural engineer, Mike Suprenant, will be based on the minimum soil bearing capacity as specified in the current version of the Uniform Building Code (UBC) when submitted for plan review Thank you for your consideration and cooperation in this matter Respectfully submitted, Gerald A Selah, Architect, AIA 8706 LAKE ASHMERE DRIVE, SUITE 300 - SAN DIEGO, CALIFORNIA 92119 TELEPHONE 6198571466 • FAX 6194609226 • E-MAIL SELAHQrCh<S!OOl com MEMBER AMERICAN INSTITUTE OF ARCHITECTS Feb-14-2008 1] 20am From-farmer case fedor T-961 P 002/003 F-658 City of Ca r Isba Building Department CERTIFICATE OF COMPLIANCE SCHOOL FEES OR OTHEft MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to Issuing a building permit The City will not Issue any building permit witnoui a oomplaied school fee form. Project Name Building Permit Plan Check Number: Project Address APN.. Project Applicant (Owner Name) Project Description Building Type Residential: Second Dwelling Unit Residential Additions Commercial/Industrial City Certification of Applicant Information: HACK RESIDENCE CB072452 2065 CALETA CT 215-110-09-00 PHIL HACK RESIDENTIAL ADDITION V-N New Dwelling Units Square Feet of Living Area in New Dwelling Square Feet of Living Area In SDU 818 Net Square Feet New Area Square Feet Floor Area HQOL TS WITHIN THE CITY OF CARLSBAD Carlsbad Unified School District 6225 El Camino Red Carlsbad CA 92009 (331-5000) Vlstn Unified School District 1234 Arcadia Drive Vista CA 92083 (726-2170) Ran Marciu Unified School District 215 Mate Way Son Marcos, CA 92069 (290*2649) Contact' Nancy rink? (By Ann*. Only) EncSnltan Union School District 101 South Raiioho Santa To Rd EnclnitzB, CA 92024 (944-4300 art 166) Sun Diegulto Union High School District TlOBncinitnaBlvd Cncinltas, CA 92024 (753-6491) Certification of Applicant/Owners. The person axeuullug into cledaratlun ("Owner1) certifies under penalty of peijury that (1) the Information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended cartffication of payment and pay the additional feaJf Owner requests en Increase In the number of dwelling units or square fbLridiju aflei (he building permit le Issued o/if th^lnliJa! determination of units or square rootage \* found to be Incorrect, and that (2) the Owner is the owner/cteveloperfcf thl above described projeot(s), or that the person executing this declaration Is authorized to sign on bejjalfof jKrOwner Ml/ Stgnanire; Revised 3/30/20D6 Date -I Feb-14-2008 1120am From-farmer cass fsdor T-9G1 P 003/003 F-65B SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school districts}) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. SCHOOL DISTRICT- The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This Es to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER WALTER FREEMAN ASSISTANT SUPERINTENDENT — CARLSBAD UNIFIED SCHOOL DISTRICT 6225 EL C\MINO REAL <-AKL5HAD,CA 82009 Revised 3/30/2006 I [ CARLSBAD UNIFIED SCHOOL DISTRICT \ \ JEFFERSON ELEMENTARY \ | AVIARA OAKS ELEMENTARY I | CARLSBAD HIGH SCHOOL j | CARLSBAD VILLAGE ACADEMY \ | VALLEY MIDDLE SCHOOL | | BUENA VISTA SCHOOL RECEIVED FROM frit (If Applicable) PARENT OF PAYMENT FOR | | MAGNOLIA ELEMENTARY \ \ AVIARA OAKS MIDDLE SCHOOL | | CALAVERA HILLS SCHOOL \ \ PACIFIC RIM | | KELLEY SCHOOL [ | CALAVERA HILLS MIDDLE SCHOOL | | HOPE SCHOOL | | OTHER L. 0 O 0 U -& ACCOUNT NUMBER DATE AMOUNT •s RECEIVED BY TOTAL