Loading...
HomeMy WebLinkAbout2066 MAR AZUL WAY; ; CB030405; Permit-10-29-2003 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB030405 Building Inspection Request Line (760) 602-2725 2066 MAR A2UL WY CBAD RESDNTL Sub Type 2151302700 Lot# $64,066 00 Construction Type Reference # 0 Structure Type 0 Bathrooms DIMITROFF RES 622 SF SUNRCOM RAD 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Ong PC# Plan Check# ISSUED 02/10/2003 SB 10/29/2003 10/29/2003 Applicant SUN BOSS CORPORATION Owner DIMITROFF FAMILY TRUST 03-24-99 2313 HALL AVENUE 92509 909 782-2360 2066 MAR AZUL WAY CARLSBAD CA 92009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $41181 Meter Size $0 00 Add'l Reel Water Con Fee $267 68 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $641 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee Housing Credit Fee $0 00 Master Drainage Fee $0 00 Sewer Fee Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $000 $000 $000 $000 $000 $000 $000 $705 90 Total Fees $705 90 Total Payments To Date $267 68 Balance Due $438 22 7585 10/29/03 0002 Inspector BUILDING PLA^SPP -J- IN STORAGE ATTACHED 438-22 FINAL APPROVAL Date 'Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1ii PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK EST VAL O Qfofe Plan Ck Deposit Validated By Date Address (include Bldg/Suite ft)Business Name (at this address) Lot No Subdivision Name/Numbei ^ Exis/in ^SQ FT Legal Description Descri / 2 CONTACT PER'SON (if different from applicant] Name . f Address / 3 APPLICANT \SA Contractor D'Agent for Contractor T 0 Owner 1[|D Agent forbwner State/Zip // /Telephone # Fax # Name 5 CONTRACTOR - COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption^_Any violation of Sectioq 7031 5 by anyjapplicarH for a permit subjects the applicant to a c^|l penalty of notjnore than five hundred dollars [$500]) 5Z/.AJ Name ' - State License # yf'OLp}^ Designer Name State License # 1 Address ji ./"7 License Class (_f' Address -f~\/fo-V City c7 f State/Zip Telephone"f > City Business License # I <_ / D 77 cI ' ' \ City State/Zip Telephone /\)e ^j/vo ; X Workers' WORKERS' COMPENSATION1"^ :: T" :'*' ' fs!;m i ••'-,, ' *"" "^* ****':•• ^V :*:%,.„,... Z'"" Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance e work for which this permit is issued n I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compgnsation insurance carrier and policy number are Insurance Company I^V/ifC^- /^U~^ Policy No^^-^/2y f£ "* &&^ 7 Expiration Date <_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [*100] OR LESS) / n CERTIFICATE OF EXEMPTION I certifcothat in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to thsAvorkers' Comperisation Laws of California WARNING Failure tofseoure worlferX^BOmpeimtion coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred Least of compensation damages as provided for in Section 3706 of the Labojf code jrterest and attorney s fees I ) &//£>// / thousand dollars ( \/SIGNATURE_ ^ ____ ^ _ ' 7 OWNER-Btm-DER DE^ARAf ION W DATE ' *"- 4 ,„„. / / ^, .-- , ,: I hereby affirm that I am exempt from the Contractor's License Law for the following reason Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) Q I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement CD YES ONO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person tq coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE^HISjSECTION FORWpW-ff«/Of/Vr/>!lli BUILDING PERMITS ONLY; ^ •• • i;NbH j :%; «; Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? d YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' f~l YES 1~1 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' d YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8%,: CONSTRUCTION LENDING AGENCY ;i '"S!T:S.: ' " "•'.!.„-,< "'- •• '•* '•' ™ '•*";T ' %: I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS 9 APPLICANT CERTIFICATION ••'•ie%:- .,;h •;•••• -.... •, w-w - •••• ^ • ,. I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required f o/^*cavation4 oy^r 5d" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued byfhfe buildinoyfju31^' under the provisions of this Code shall expire by limitation and become null and void if the building or work Authorized by such permit is not cowmei/ced withjfejreo dayaTrom the date of such permit or if the building or work authorized by such perjnit is suspended or abandoned kt any time after the work is cormfence^^>f^MpffW-4^Ldays (Section 106 4 4 Uniform Building Code) .^APPLICANT'S SIGNATURE /'^^fl/^/XnLy DATE i/ i WHITE File YELLOW Applicant PINK Finance ^ * Inspection List Permit* CB030405 Type RESDNTL RAD Date Inspection Item 01/25/2005 89 01/25/2005 89 12/16/2004 89 11/16/2004 89 07/01/2004 17 07/01/2004 18 06/30/2004 17 06/30/2004 18 06/11/2004 17 06/09/2004 17 06/07/2004 17 05/18/2004 18 04/05/2004 14 04/05/2004 34 Final Combo Final Combo Final Combo Final Combo Interior Lath/Drywall Exterior Lath/Drywall Interior Lath/Drywall Exterior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Exterior Lath/Drywall Frame/Steel/Bolting/Weldm Rough Electric Inspector Act - PY PY PY PS PS PS PS PS PY PY PY PY PY Rl AP CO NR AP AP CA CA CO NR NR NR AP AP DIMITROFF RES 622 SF SUNROOM Comments NO ONE HOME 9AM RESET OR THURS AM SRR ATTACHED NOTICE-CHECK STAIRWAY NO ONE HOME NOONEHOME-1 10PM SEE NOTICE ATTACHED Wednesday, January 26, 2005 Page 1 of 1 City of Carlsbad Bldg Inspection Request For 01/25/2005 Permit* CB030405 Title DIMITROFF RES 622 SF SUNROOM Description Inspector Assignment PY 2066 MAR AZUL WY Lot 0 Type RESDNTL Sub Type RAD Job Address Suite Location APPLICANT SUN BOSS CORPORATION Owner DIMITROFF FAMILY TRUST 03-24-99 Remarks Phone 8004395557 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs/CVs Date 12/16/2004 11/16/2004 07/01/2004 07/01/2004 06/30/2004 06/30/2004 06/11/2004 06/09/2004 06/07/2004 05/18/2004 04/05/2004 04/05/2004 Inspection Historv Description 89 Final Combo 89 Final Combo 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 14 Frame/Steel/Bolting/Welding 34 Rough Electric Act CO NR AP AP CA CA CO NR NR NR AP AP Insp PY PY PS PS PS PS PS PY PY PY PY PY Requested By MIKE Entered By CHRISTINE Comments NO ONE HOME 9AM RESET OR THURS AM SRR ATTACHED NOTICE-CHECK STAIRWAY NO ONE HOME NOONEHOME-1 10PM SEE NOTICE ATTACHED City of Carlsbad Bldg Inspection Request For 12/16/2004 Permit* CB030405 Title DIMITROFF RES 622 SF SUNROOM Description Inspector Assignment PY Type RESDNTL Sub Type RAD 2066 MARAZULWY Lot 0 Job Address Suite Location APPLICANT SUN BOSS CORPORATION Owner DIMITROFF FAMILY TRUST 03-24-99 Remarks Phone 8004395557 Inspector Total Time Requested By MIKE Entered By CW CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Associated PCRs/CVs Date 11/16/2004 07/01/2004 07/01/2004 06/30/2004 06/30/2004 06/11/2004 06/09/2004 06/07/2004 05/18/2004 04/05/2004 04/05/2004 Inspection History Description 89 17 18 17 18 17 17 17 18 14 34 Final Combo Interior Lath/Drywall Exterior Lath/Drywall Interior Lath/Drywall Exterior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Exterior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Act NR AP AP CA CA CO NR NR NR AP AP Insp PY PS PS PS PS PS PY PY PY PY PY Comments NO ONE HOME 9AM RESET OR THURS AM SRR ATTACHED NOTICE-CHECK STAIRWAY NO ONE HOME NOONEHOME-1 10PM SEE NOTICE ATTACHED CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME i •^s- flk-JH JL*&(^1^> J/rO *' FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION/CONTACT. -TV. YES PHONE BUILDING INSPF|CTOF^CODE ENFORCEMENT OFFICER ® City of Carlsbad Bldg Inspection Request For 06/11/2004 Permit# CB030405 Title DIMITROFF RES 622 SF SUNROOM Description Inspector Assignment PY Type RESDNTL Sub Type RAD Job Address 2066 MAR AZUL WY Suite Lot 0 Location APPLICANT SUN BOSS CORPORATION Owner DIMITROFF FAMILY TRUST 03-24-99 Remarks Phone 00000000000 Inspector Total Time CD Description 17 Interior Lath/Dry wall Act Comment Requested By ALAN Entered By ROBIN Associated PCRs/CVs Inspection History Date Description 06/09/2004 17 Interior Lath/Drywall 06/07/2004 17 Interior Lath/Drywall 05/18/2004 18 Exterior Lath/Drywall 04/05/2004 14 Frame/Steel/Bolting/Welding 04/05/2004 34 Rough Electric Act Insp Comments NR PY NO ONE HOME NR NR AP AP PY PY PY PY NOONEHOME-1 10PM SEE NOTICE ATTACHED CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? , CONTACT _ n YES PHONE CODE ENFORCEMENT OFFICER ® Jun-17-04 02 23pm Frcm-Four Saasons Solar 6312189076 T-982 P 001/D02 F-213 i53E3;S u N R o o|M s SUNROOMS CONSERVATORIES PATIO ROOMS CJ.A93 « SCREEN ENCLOSUKZS SKYLIGHTS Otttdvor Living.,.Indooir$™ ENGINEERING DEPARTMENT 5005 Veterans Memorial Highway, HotarooK, New York 11741 Tel (631) 563^000 • Fax (631) 216-9076 1 -800-FOUR-SEASONS (1-800-368-7732) Internet http /Awww four-seasons-sunrooms com E-Mail infb@four-seas3rs-sunrooms com June 17,2004 Subject Dinutroff Project Donn Stanley As per the conversation with Lawrence Duffy, adding the sheetrock to the roof of the project won't affect the structural integrity- of the room The sheetrock will add 2 psf to the dsad load, which will drop the allowable load from 20 psf to 18 psf The original analysis used a conservative design load of 20psf, however the required live load is only 14 psf due to the tributary area and the slope 4/12 Therefore the addition of the sheetrock will have no affect on the structural integrity of the room If there are any questions, feel free to contact rne Smceiely, d^ZZw-t*-"-^' \~*<^*^4s*~—J Lawrence Fischer, PE Four Seasons Consulting Engineer LAWRENCE FISCHER CONSULTING ENGINEER PHONE # 1(407) 482-6841 FAX #1(407)482-6841 City of Carlsbad Bldg Inspection Request For 06/09/2004 Permit# CB030405 Title DIMITROFF RES 622 SF SUNROOM Description Type RESDNTL Sub Type RAD Job Address 2066 MAR AZUL WY Suite Lot 0 Location APPLICANT SUN BOSS CORPORATION Owner DIMITROFF FAMILY TRUST 03-24-99 Remarks DOOR WILL BE OPEN Inspector Assignment PY Phone 0000000000 Inspector L,. Total Time CD Description 17 Interior Lath/Drywall Requested By N/A Entered By ROBIN Act Comment ^Lft Associated PCRs/CVs Inspection History Date Description Act Insp Comments 06/07/2004 17 Interior Lath/Drywall NR PY NO ONE HOME-1 10PM 05/18/2004 18 Exterior Lath/Drywall NR PY SEE NOTICE ATTACHED 04/05/2004 14 Frame/Steel/Bolting/Weldmg AP PY 04/05/2004 34 Rough Electric AP PY CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION Zofcc PERMIT NO (760) 602-27,00 1635 FARADAY AVENUE TIME. I -t 1 FOR INSPECTIONCALL (760) 602-2725 I RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT YES PHONE CODE ENFORCEMENT OFFICER ® City of Carlsbad Bldg Inspection Request For 05/18/2004 Permit* CB030405 Title Description DIMITR I40 OFF RES 622 SF SUNROOM Inspector Assignment PY Sub Type RAD 2066 MAR AZUL WY Lot 0 Type RESDNTL Job Address Suite Location APPLICANT SUN BOSS CORPORATION Owner DIMITROFF FAMILY TRUST 03-24-99 Remarks Phone 8587175435 Inspector Total Time CD Description 18 Exterior Lath/Drywall Act Comment Requested By ALAN Entered By ROBIN Associated PCRs/CVs Inspection History Date Description Act Insp Comments 04/05/2004 14 Frame/Steel/Boltmg/Welding AP PY 04/05/2004 34 Rough Electric AP PY CITY OF CARLSBAD BUILDING DEPARTMENT NOTIC (760) 602-2700 1635 FARADAY AVENUE DATE •f TIME LOCATION PERMIT NO IJ(j FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? L .1 YES FOR FURTHER INFORMATION, CONTACT t"iTHER INFORMATION, C( -YftMA 4 $»-— I 'BUILDING INSPECTOR PHONE 'BUILDING INSPECTOR F v CODE ENFORCEMENT OFFICER CHRISTIAN Wl IEELEK E N <:; i N r. r. R i N c; DAILY R I-PORT Pro|ect Name Proiect # Proiect Address Permit #Plan File # Contractor Architect Subcontractor Engineer l~l Reinforced Concrete D Shop Welding l~l Pre-Stressed Concrete D Field Welding l~1 Reinforced Masonry l~l Fireproofing 0"Epoxy Anchorsa Material/Equipment We°'her -70° Date Time Arrived Time Departed f £ / ^—Hours Charged 3T-Z"/ y v A To Unless noted otherwise, the work observed is, to the best of my knowledge, in compliance with the dtoprWed plans,and specifications Inspector/Technician's Signafure Reg # Superintendent's Signature Date Inspector/Technician (Print or Type) 4925 Mercury Street 4- San Diego, CA 92111 -f 858-496-9760 + I-1 AX 858-496-9758 EsGil Corporation In fartnersdip with government for (RuiUtng Safety DATE October 21, 2OO3 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-405 SET VIII PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room For Dimitroff Residence 1X1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Bill Elizarraras Enclosures Struct & Title 24 calc's Esgil Corporation D GA D MB D EJ D PC LOG trnsmtldot 9320 Chesapeake Drive, Suite 208 *• San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (RuiCtfing Safety DATE October 3, 2003 a APPLICANT a (JURJSJ) JURISDICTION Carlsbad a PDtfTREViEWER a FILE PLAN CHECK NO O3-405 SET VIII PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to James Olson 1919 San Diego Ave San Diego, CA 92110 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted James Olson Telephone # 619-299-8439 Date contacted /o/w/03 (by fay-) Fax # 619-298-8439 ** Mail ---Telephone Fax <--' In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC LOG trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad O3-405 October 3, 2OO3 * THESE CORRECTIONS ARE IN RESPONSE TO THE LEAD ENGINEER (MR LAWRENCE DUFFY) RESPONSES DATED 9/18/03. • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Final Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) 3 Provide lateral analyses for the existing Dwelling, the submitted lateral analyses are only for the proposed addition and do not include the load transfer from the addition to the existing structure 4 What is the MWFRS stand for in the Engineers response and where is this referenced in the UBC 5 Provide an approved listing for the allowable core shear for the 13' panels. (ICBO Listing). 6 Provide a positive connection for the ridge to post and post to support (The screws into the end gram of the Micro-Lam beam is not adequate. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras / Chuck Mendenhall at Esgil Corporation Thank you EsGil Corporation In Partners flip with government for (BuiGfing Safety DATE September 12, 2O03 a APPLICANT JURISDICTION Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO 03-405 SET VII PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person Xj The applicant's copy of the check list has been sent to Donn Stanley 1919 San Diego Ave San Diego, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Donn Stanley Telephone # 619-299-8439 Date contacted ita/^ (by £*v) Fax # 619-298-8439 Mail Telephone Fax"'' In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC LOG tmsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 Carlsbad O3-4O5 September 12, 2O03 •> The following corrections are from the original deficiency list, and were either not addressed or a result of new changes * THESE CORRECTIONS ARE IN RESPONSE TO THE LEAD ENGINEER (MR LAWRENCE DUFFY) RESPONSES DATED 9/5/03 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Final Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) The following corrections apply to the Four Seasons Engineered Designs. 5 Clarify the computer lateral loads per previous correction E HOW DOES THE SUN ROOM RESIST LATERAL LOADS ALONG THE TWO OPEN SIDES SHOWN IN THE ELEVATIONS ON SHEET A1? IT IS NOT CLEAR FROM THE COMPUTER DESIGN WHA T YOU ARE PROPOSING OR HOW THE ENGINEER HAS PROPOSED IN THE 'DESIGN TO RESIST THE LATERAL LOADS show hand calculations to clanfy loads Plans show 4 1/V aluminum clac? roof panels not OS3 In Accordance with the response from Lawrence Duffy, Show plywood roof diaphragms, roof rafters and nailing on the plans and adjust calculations to reflect plywood diaphragm Carlsbad O3-405 September 12, 2O03 6 Provide a design calculation for the micro-lam ridge beam at the Sunroom Expand the design to show loadmci design Moment. Sheai & Section required based on allowable stress Tms has not been addressed The complex computer design can not be deciphered There is no way to determine whether the loads, design stresses or lateral support comply with the code. Further there is a hand calculations for a 3x16 wood beam that is designed as fixed at one end and pinned on the other opposite end? Clarify where this beam applies on the plans and how it is fixed at one end *> THE COMPUTER DESIGN AS PRESENTED CAN NOT BE DECIPHERED"? • The computer generated design stii! can not be deciphered • It is not acceptabjejo show code compliance • ThjS _does not assist in sh_Qvv_jrifl-h_Qw the design relates to the * proposed computer design. • Provide hand cajcujations to demonstrate code co;r)joij_anc_e •^ its not clear how this design relates to the structure shown on the plans or whether fie design even applies to the proposed structure N> } can not determine loading, member stresses or connections. Th--- design engineer Lauren Duffy incise, cited that hand calculations on Excel forr'int are provided m i.he 7 ''''' half of !;IP oa'Cutetions i did find the Excel format but those do not help with the review What is tho loading'? What members are you analyzing7 There is no assign for lateral or connections The design still cannot be deciphered. £ Prc'Vidc- calculations t:-at con bo deciphered and th,-?: show you have applied al: code relaled loads (Born vertical o< Lale^ai) an,.i dysiyn ali members and connections No further review will be made until calculations that can be deciphered are provided. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras / Chuck Mendenhall at Esgil Corporation Thank you EsGil Corporation In Partnership with government for <BuiC£ing Safety DATE September 2, 2003 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-405 SET VI PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Donn Stanley 1919 San Diego Ave San Diego, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Donn Stanley Telephone # 619-299-8439 Date contacted ^/Z/fcj, (by fry) Fax # 619-298-8439 Mail./ Telephone FaxiX In Person D REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC LOG trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 Carlsbad 03-405 September 2, 2003 •^ The following corrections are from the original deficiency list, and were either not addressed or a result of new changes. * THESE CORRECTIONS ARE IN RESPONSE TO THE LEAD ENGINEER (MR. LAWRENCE DUFFY) RESPONSES DATED 8/15/03. • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Final Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) The following corrections apply to the Four Seasons Engineered Designs. 5 Clarify the computer lateral loads per previous correction E HOW DOES THE SUN ROOM RESIST LATERAL LOADS ALONG THE TWO OPEN SIDES SHOWN IN THE ELEVATIONS ON SHEET A1? IT IS NOT CLEAR FROM THE COMPUTER DESIGN WHAT YOU ARE PROPOSING OR HOW THE ENGINEER HAS PROPOSED IN THE DESIGN TO RESIST THE LATERAL LOADS Show hand calculations to clarify loads Plans show 4 V" aluminum clad roof panels not OSB. 6 Provide a design calculation for the rnicro-lam ridge beam at the Sunroom Expand the design to show loading, design Moment, Shear & Section required based on allowable stress This has not been addressed. Carlsbad 03-405 September 2, 2O03 ^ THE COMPUTER DESIGN AS PRESENTED CAN NOT BE DECIPHERED'? 9 The computer generated design still can not be deciphered. » It is not acceptable to show code compliance. o This does not assist in showing how the design relates to the proposed computer design. o Provide hand calculations to demonstrate code compliance. «$> Its not clear how this design relates to the structure shown on the plans or whether the design even applies to the proposed structure ^ I can not determine loading, member stresses or connections. •^ The design engineer Lauren Duffy indicated that hand calculations on Excel format are provided in the 2nd half of the calculations, I did find the Excel format but these do not help with the review What is the loading? What members are you analyzing? There is no design for lateral or connections • The design still cannot be deciphered. •^ Provide calculations that can be deciphered and that show you have applied all code related loads (Both vertical & Lateral) and design all members and connections. No further review will be made until calculations that can be deciphered are provided. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras / Chuck Mendenhall at Esgil Corporation Thank you EsGil Corporation In Partnership witfi government f or QSuibfing Safety DATE August 8, 2003 a APPLICANT JURISDICTION Carlsbad OPtATTREVlEWER Q FILE PLAN CHECK NO 03-405 SET V PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck IX] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Donn Stanley 1919 San Diego Ave San Diego, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Donn Stanley Telephone* 619-299-8439 Date contacted Z-Z-e*, (by Jzu/) Fax # 619-298-8439 Mail Telephone Fax i^ln Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ n PC 7/31/03 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad 03-405 August 8, 2OO3 •>• The following corrections are from the original deficiency list, and were either not addressed or a result of new changes • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGi! Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Final Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) The following corrections apply to the Four Seasons Engineered Designs. 5 Clarify the computer lateral loads per previous correction E HOW DOES THE SUN ROOM RESIST LATERAL LOADS ALONG THE TWO OPEN SIDES SHOWN IN THE ELEVATIONS ON SHEET A1? IT IS NOT CLEAR FROM THE COMPUTER DESIGN WHAT YOU ARE PROPOSING OR HOW THE ENGINEER HAS PROPOSED IN THE DESIGN TO RESIST THE LATERAL LOADS Show hand calculations to clarify loads 6 Provide a design calculation for the micro-lam ridge beam at the Sunroom Expand the des/qn to show loading, design Moment, Shear & Section required based on allowable stress Carlsbad O3-4O5 August 8, 2003 ^ THE COMPUTER DESIGN AS PRESENTED CAN NOT BE DECIPHERED-? •> Its not clear how this design relates to the structure shown on the plans or whether the design even applies to the proposed structure. •> I can not determine loading, member stresses or connections. *fr The design engineer Lauren Stufy indicated that hand calculations on Excel format are provided in the 2nd half of the calculations, I did find the Excel format but these do not help with the review. What is the loading? What members are you analyzing? There is no design for lateral or connections. *£• Provide calculations that can be deciphered and that show you have applied all code related loads (Both vertical & Lateral) and design ail members and connections. No further review will be made until calculations that can be deciphered are provided. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras / Chuck Mendenhall at Esgil Corporation Thank you EsGil Corporation In (Partners/zip wit A (government for (Ruihhng Safety DATE June 13, 2003 a APPLICANT JURISDICTION Carlsbad Q FILE PLAN CHECK NO 03-405 SET III PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person [X] The applicant's copy of the check list has been sent to Donn Stanley 1919 San Diego Ave San Diego, CA 92110 Esgil Corporation staff did not advise the applicant that the plan check has been completed X| Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Donn Stanley Telephone # 909-782-2360 Date contacted 6-/3-*3 (by^x) Fax # 909-684-8217 Mailf Telephone Fax^ In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 6/6/03 tmsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 * Fax (S58) 560-1576 Carlsbad O3-4O5 June 13, 2003 • The following corrections are from the original deficiency list, and were either not addressed or a result of new changes . PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil . Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete Final Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS EPOXY ANCHORS When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form Carlsbad O3-4O5 June 13,2OO3 5 Clarify the computer lateral loads per previous correction E HOW DOES THE SUN ROOM RESIST LATERAL LOADS ALONG THE TWO OPEN SIDES SHOWN IN THE ELEVATIONS ON SHEET A1? IT IS NOT CLEAR FROM THE COMPUTER DESIGN WHAT YOU ARE PROPOSING OR HOW THE ENGINEER HAS PROPOSED IN THE DESIGN TO RESIST THE LATERAL LOADS. 6 Provide a design calculation for the micro-lam ridge beam at the Sunroom To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you OB/13/2003 03 27 FAX 30B68«8217 SUN BOSS FOUR SEASONS ESGIL CORP Fax, 18585601576 Jun 13 SUN BOSS ; SO 0005/005 o 1015 P Ob Carlsbad 03.4O5 June 13, 2003 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No, O3-4OS Job Address or Legal Description 2066 Mar Axul Way Owner M ^ You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector arc in addition 10 the inspections normally required by the County Building Code The Special inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given unbl all Special Inspection reports have been received and approved by the City of Carlsbad building department <2A- Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet Carlsbad 03-405 June 13, 3O03 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION; ^^L M PLAN CHECK NUMBER: °3 -4o5 OWNER'S NAME:hr?- 1> 1 I, es the owner, or agent of the owner (contractors may coj employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special Inspector(s) aa required by Uniform Building Code (UBC) Section 1701 1 for the/constructlorKb/oJect located at the site listed above UBC Section 106 3 5 i / M Signed I, as the engineer/architect of record, certify thtt I have prepared the following special m program as required by UBC Section 106.3 5 for the construction project located at above, Signed 1. List of wortffequlrlng special Ins 8 Soils Compliance Prior to Foundation Inspection D Field Weld? Structural Concrete Over 2500 PSI Q High 8tre Presiressed Concrete Sf Expansi Anchor* ^ D Structural Masonry Fireproof ing D Designer Specified D Sorayed-On D Other 2. Name(*) of IndJvidual(s) or firm(8) responsible for the spsclal inspections listed A. B C. 3. Duties of the special irupeetorefgr the work listed above. A "ro B. C. Spec«l ln«pertors snail chtck In with lh» City and present (h«ir erodtntiali for approval beginning want en trw Jot> EsGil Corporation In Partnership with government for 'SmCding Safety DATE 4/4/O5 a APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 03-405 SET II PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck [XJ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Donn Stanley 1919 San Diego Ave San Diego, CA r>r>r>r>r> I I Esgil Corporation staff did not advise the applicant that the plan check has been completed X Esgil Corporation staff did advise the applicant that the plan check has-been completed &0ty-7<f;i- Person contacted Donn Stanley Telephone # 0-40 200 0430 Date contacted 4-</-63 (by £»-) Fax # 610208 8130 Mail Telephone -^ Fax ^ In Person fiofyCffV ] REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 3/27/03 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 Carlsbad 03-405 4/4/05 • Generally these plans are structurally incomplete and a through plan check can not be done. The following list is just a guide. Additional corrections may follow after resubmittal. THIS COMMENT STILL APPLIES. SEE THE CORRECTIONS BELOW AND THE NOTES IN BOLD AT THE END OF THE ITEMS. • PLANS Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) THIS APPLIES TO THE SUNROOM PLANS AS WELL AS THE PLANS FOR THE EXISTING HOUSE. Provide a complete set of plans drawn to a viewable scale, detailed showing and referencing all structural connections (wall, roof, floor systems and shear walls), member sizes (new and existing) complete cross sections, show existing window sizes (Light and ventilation) and electrical layouts THERE WERE NO STRUCTURAL PLANS FOR THE SUNROOM STRUCTURE. THE SKETCHY STRUCTURAL DETAILS AND INFORMATION ON SHEET A1 ONLY RAISE MORE QUESTIONS. A HOW IS THE NEW STRONG WALL ANCHORED TO THE EXISTING FOUNDATION? Carlsbad O3-405 4/4/05 B HOW IS THE NEW STRONG WALL CONNECTED TO THE EXISTING DECK/FLOOR SYSTEM ABOVE? C WHAT IS THE PURPOSE OF THE NEW 4X10 BEAMS BETWEEN THE LIVING ROOM AND FOYER ? WHAT WAS THERE PRIOR TO THE PROPOSED REMODEL'? WAS THE AREA WHERE THE NEW 4X10's ARE TO BE INSTALLED AN EXISTING BEARING WALL? D WHERE ARE THE CONSTRUCTION PLANS AND DETAILS FOR THE SUNROOM? WHAT TYPE OF ROOF FRAMING IS PROPOSED FOR THE SUN ROOM? E HOW DOES THE SUN ROOM RESIST LATERAL LOADS ALONG THE TWO OPEN SIDES SHOWN IN THE ELEVATIONS ON SHEET A1? IT IS NOT CLEAR FROM THE COMPUTER DESIGN WHAT YOU ARE PROPOSING OR HOW THE ENGINEER HAS PROPOSED IN THE DESIGN TO RESIST THE LATERAL LOADS. F IT APPEARS THAT THE ROOF OF THE SUN ROOM WILL BE ENCLOSED WOOD FRAME. SEE THE REAR ELEVATION ON SHEET A1. WHAT IS THE SIZE AND SPACING OF THE ROOF JOISTS? WHAT IS THE SIZE OF THE RIDGE BEAM? HOW IS THE RIDGE BEAM SUPPORTED? WHAT IS THE THICKNESS AND TYPE OF ROOF SHEATHING? 8 Sleeping rooms shall have a window or exterior door for emergency escape Sill height shall not exceed 44" above the floor Windows must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools Section 3104 THIS APPLIES TO THE SLEEPING LOFT. THE EXISTING BED ROM ADJACENT TO THE NEW SUN ROOM SHOWS AN EXTERIOR 5040 WINDOW BUT THERE IS NOTHING ON THE PLANS SHOWING EMERGENCY ESCAPE WINDOW SIZE FOR THE SLEEPING LOFT. 9 Window area must be at least 1/10 of the floor area Section 1203 3 WHAT IS THE WINDOW SIZE FOR THE EXISTING SLEEPING LOFT? 10 Openable window area in habitable rooms must be 1/20 of the floor area Section 1203 3 THIS APPLIES TO THE SLEEPING LOFT 11 Specify roof slope SPECIFY THE SUN ROOM ROOF PITCH ON THE PLANS. WHAT IS THE EXISTING ROOF COVERING THAT WILL BE USED OVER THE SUN ROOM. IS THE SUN ROOM ROOF PITCH ADEQUATE FOR THE NEW ROOFING? Carlsbad 03-405 4/4/05 15 Show on the plans all structural requirements developed in the structural calculations Section 106 3 3 THIS APPLIES TO THE SUN ROOM. THERE ARE NO CONSTRUCTION DETAILS FOR THIS PART OF THE PROPOSED STRUCTURE. • NEW ENERGY CORRECTION ITEMS A. WHAT IS THE PURPOSE OF THE NEW ENERGY DESIGN DOCUMENTS? IS THE SUN ROOM NOW PROPOSED TO BE CONDITIONED HABITABLE SPACE? B THE ENERGY DESIGN REQUIRES THAT THE NEW SUN ROOM HAVE R-19 INSULATION. SHOW THIS ON THE PLANS. C PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE NEW SUN ROOM WINDOWS WHCH ARE SHOWN TO HAVE A U VALUE = 0.25 AND A SHGC=0.35. THESE ARE EXTREMELY LOW VALUES AND NOT LISTED AS A STANDARD PRODUCT IN THE ENERGY DESIGN MANUAL. D THE ENERGY FORM CF-1R MUST BE SIGNED AND IMPRINTED ON THE PLANS. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you EsGil Corporation In Partnership with government for <Bu.iC(fing Safety DATE February 21, 2O03 a APPLICANT JURISDICTION Carlsbad OPTAN REVIEWER a FILE PLAN CHECK NO 03-405 SET I PROJECT ADDRESS 2066 Mar Azul Way PROJECT NAME Sun Room for Dimitroff Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person IXl The applicant's copy of the check list has been sent to Donn Stanley 1919 San Diego Ave San Diego, CA Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Donn Stanley (3+nn'J*f\ Telephone # 619-299-8439 Date contacted -2-Z/-*3 (by«*. ) Fax # 619-298-8439 Mail Telephone J Fax In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 2/13/03 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576 Carlsbad O3-405 February 21, 2003 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO 03-4O5 JURISDICTION Carlsbad PROJECT ADDRESS 2066 Mar Azul Way FLOOR AREA 622 sq ft Sunroom Add'nSTORIES 2 HEIGHT 24' REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED February 21, 2003 DATE PLANS RECEIVED BY ESGIL CORPORATION 2/13/03 PLAN REVIEWER Bill Elizarraras FOREWORD (PLEASE READ)- This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad O3-4O5 February 21, 2O03 • Generally these plans are structurally incomplete and a through plan check can not be done. The following list is just a guide. Additional corrections may follow after resubmittal. • PLANS 1 Please make all corrections on the original tracings and submit two new complete sets of prints, to Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (858) 560-1468 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) 3 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC 4 Provide a complete set of plans drawn to a viewable scale, detailed showing and referencing all structural connections (wall, roof, floor systems and shear walls), member sizes (new and existing) complete cross sections, show existing window sizes (Light and ventilation) and electrical layouts 5 The existing spiral stairway may not be used for required exit when the area served is greater than 400 sq ft Section 1003 3383 Show a second conforming exit from second story 6 Show locations of permanently wired smoke detectors with battery backup a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) On each story • NOTE Detectors shall sound an alarm audible in all sleeping areas of the unit Section 3109 1 7 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered Section 310 9 1 2 8 Sleeping rooms shall have a window or exterior door for emergency escape Sill height shall not exceed 44" above the floor Windows must have an openable area of at least 5 7 square feet with the minimum openable width 20" and the minimum openable height 24" The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools Section 310 4 Carlsbad O3-405 February 21, 2O03 9 Window area must be at least 1 /10 of the floor area Section 1203 3 10 Openable window area in habitable rooms must be 1/20 of the floor area Section 12033 11 Specify roof material and application Chapter 15 12 Specify on the plans the following information for the roof materials, per Section 10633 a) Manufacturer's name b) Product name/number c) ICBO approval number, or equal 13 Specify roof slope 14 Specify minimum % inch per foot roof slope for drainage or design to support accumulated water Section 1506 1 15 Show on the plans all structural requirements developed in the structural calculations Section 106 3 3 16 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments • MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you Carlsbad O3-4O5 February 21, 2003 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO O3-405 PREPARED BY Bill Elizarraras DATE February 21, 20O3 BUILDING ADDRESS 2066 Mar Azul Way BUILDING OCCUPANCY R3/U1 TYPE OF CONSTRUCTION VN BUILDING PORTION Sun Room Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA II Valuation (Sq Ft) Multiplier 622 cb Per City Value By Ordinance Reg Mod VALUE ($) 64,066 64,066 Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review Repetitive Fee Complete Review D Other D Hourly Structural Only Hour* Esgil Plan Review Fee Comments $40281 $261 83 $225 57 Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER DATE ADDRESS Hour LOu~ij SIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFRCE BUILDING OTHER PLANNER -/;> O ENGINEER j DATE Docs/Mlsf ormsmanning EngtnHnng ApproMais 01/23/2083 15:22 I I I I I 1 I I I I I I I I I I I 6312189076 * ENGINEERING PAGE 81/81 FOUR SFASONS SUNKOOMS SUNROOUS CONMMVATQIUCK PATIO ROOMS OW>»» * SCHU* ENCLOSURES SXVUGHT*Outdoor Living...In4oorsiving. *oLAft WW V«Mr«ns Memorial Highwiy, Holfcroek, N«w York ITW Tei (631) 563-4000 • Fax (831; 215-9078 1-800 FOUR-SEASONS (1-800 36a-7732) Internal http MAIWW four-s»ason$-sunnpoms com E-Mail mfcxgfour-seasons-sunrooms com ENGINEERING CALCULATIONS STANDARD SYSTEM 8 MODULAR GREAT ROOM 21'-8" PROJECTION BY 33'-2" FRONT WALL WITH 4" OSB PANEL ROOF WITH H-BEAMS AND 3X16" WOOD RIDGE BEAM WITH 3 X 5-1/2" BEAM POST AND 36" ON CENTER BAYS FOR THE DIMITROFF RESIDENCE LOCATED AT 2066 MAR AZUL WAY CARLBAD, CA 92009 DATE: January 24, 2003 THE ABOVE INDICATED PROJECT HAS BEEN EXAMINED FOR 20 psf ROOF LOAD 70 mph EXPOSURE C WIND LOAD SEISMIC ZONE 4 AS PER THE 1997 UNIFORM NATIONAL BUILDING CODE ALL CONNECTIONS MUST BE ANALYZED BY OTHERS - THIS SUMMARY PERTAINS ONLY TO 7 HE MEMBER STRESSES, DEFLECTION, AND PLATE STRESSES NOTES- 1. THIS SUMMARY PERTAINS TO THE STRUCTURAL INTEGRITY OF OUR UNIT UP TO, BUT NOT INCLUDING, THE CONNECTIONS OF THE ROOM ADDITION AND TO THE EXISTING STRUCTURE AND/OR ANY NEW CONSTRUCTION. ALL CONNECTIONS BOTH TO THE ROOM ADDITION ITSELF AND TO THE EXISTING STRUCTURE AND/OR ANY NEW CONSTRUCTION MUST BE ANALYZED ACCORDING TO CONDITIONS SPECIFIC TO EACH JOB BY OTHERS, 2. A LOCAL PROFESSIONAL ENGINEER SHOULD DETERMINE THE SITE SPECIFIC LOADING AND PERFORM ANY ADDITIONAL NECESSARY CALCULATIONS, WHICH MAY INCLUDE: MINIMUM DESIGN LOADS REQUIRED BY LOCAL MUNICIPALITIES, OR ANY DRIFTING UNBALANCED SNOW LOADS PRODUCED BY ADJACENT STRUCTURES