Loading...
HomeMy WebLinkAbout2072 Mar Azul Way; ; CBR2017-1557; Permit(City of Carlsbad Print Date: 11/20/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2072 Mar Azul Way BLDG-Residential 2151304800 $236,517.40 Residential Permit Work Class: Addition Lot#: Reference#: Construction Type: Bathrooms: Orig, Plan Check#: P\an Check #: Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Description: PINPOKINTR: 267 SF AODITION AT 1ST & 2ND FLOOR// 3,637 SF REMODEL// 201 SF 2ND FLOOR DECK// 690 SF DETACHED PATIO COVER Applicant: JEFF PARSHALLE ARCHITECT JEFF PARSHALLE Po Box 230132 ENCINITAS 92023 619-985-4099 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) BUILDING PLAN CHECK FEE (BLDG) Owner: PAISAN PINPOKINTR PAISAN PINPOKlNTR 7143 Sitio Bahia CARLSBAD, CA 92009-2043 760-207-3556 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $2,724.74 Total Payments To Date: $2,724.74 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction.'' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactlons DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2017-1557 Closed -Finaled 07/12/2017 11/09/2017 TFraz 11/20/2018 9:20:44AM $0.00 $1,112.35 $340.02 $438.62 $66.00 $166.00 $92.00 $182.DO $10.00 $30.75 $232.00 $55.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 \ 760-602-8560 f I www.carlsbadca.gov . { City of Building Permit Application Plan Check No.C&<2.D17-I~ / _ 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 2. '3u~ 5 I 7 Carlsbad Ph: 780-8024719 Fax: 760-602-8558 email: buildlng@carlsbadca.gov Plan Ck. Deposit www.cgrlsbgdca.gQv tl-q Date -17-- J0B%~2.. MAfL kZJ\...y~ SUITE#/SPACE#/UNIT# IAPN --- "cf/PROJECT 11 I LOT# I PHASE# ! # OF UNITS I# BEDROOMS # BATHROOMS I TENANT BUSINESS NAME ·rsTR TYPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) l t,..\--r~ oc__ ~1Y1.~ ~ \\k\ \(.Q.O ~ ,4 Dy{ -{i l) ~ 253 if OecK. 3,(jo7 .l::>F ~ EXISTING USE I PROPOSED USE rARAGE (SF) PATIOS (SF) I DECKS (SF) ,_FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS YES □# __ NO □ YES □ NO □ YES □ NOD APPLICANT NAME (Prlma,y Contact) PRO'r.:-7 .:'.'WNER NAMEf} IN . 'TY' ~ . /trJ POK, ADDRESS ADDRESS ' ~ A-1-t!P't -i-1 '-f, ' $ 1r,C) CITY STATE ZIP CITY X'A ZIP l-A-ftl~t',Aj) 9').00~ PHONE IFAX PHONE !FAX ::f-//J -.f OJ-:!, !,'S\, EMAIL EMAIL \ I~ 1 / Pt'-1-Sc::Ln or,,e{Q c.. mP-.., U'),V,. , DESIGN PROFESSIONAL NAME CON, n:ACTOR BUS. NAME ADDRESS ADDRESS ----------CITY STATE ZIP CITY STATE ZIP PHONE __ =t: PHONE IFAX ~ ·---·-------EMAIL EMAIL l STATE LIC. # -STATE LIC.# T~---rus. LIC_# _____ - (Sec: 7031.5 Business and P_rofess1ons Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a s1~ned statementttiat he 1s licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, commending with Section 7000 of D1v1s1on 3 of the B_usmess and Professions Code} or that he is exem_P.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subJects the applicant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers' Compensation Declaration: / hereby affirm under penalty of petjury one of the following declarations D 1 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued, 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. ______________________ Policy No. _______________ Expiration Date _________ _ This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall sut:iject an employer to criminal pen allies and civil fines up lo one hundred thousand dollars (& 100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the labor code, interest and attorney's fees. ,,6$ CONTRACTOR SIGNATURE □AGENT DATE ---0 W N E R -B U I L D E R D E C L A R A T I O N ~ , ,, , I hereby afflrm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply lo an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). ~ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). D I am exempt under Section____ Business and Professions Code for this reason: 1. I personally plan to provide the major lat:ior and materials for construction of the proposed property improvement. D Yes D No 2, \ (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction {include name address I phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the fol lo coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): k, but I have co o owing persons to provide the work indicated (include name I address I phone type o rk : □AGENT DATE " --z ' , OMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or ft.tu re building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-T f)nner Hazardous Substance Account Act? 0 Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility lo be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING/AG.ENCY I hereby affinn that there 1s a construction lending agency for the perfonnance of the work this permit 1s issued (Sec 3097 (1) C1v1l Code) Lender's Name Lender's Address APPLICANT CERTIFICATION I certify that I have read the application and state that the above infonnation Is correct and that the infonnation on the plans ls accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the atove mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA perm~ is required for excavations CJ,Jer 5'0' deep and demo!ition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under_lhe provisions of this Code shall expire by limitation alld become null and void W lhe l:xJildilg orworK authorized by such permit is not commenced within 180 days from the date of such permit or W the b · r1< authorized by such pennlt is s or abandoned at any time after the woo; is commenced for a period of 180 days (section 106.4.4 Uniform Building Code). r , DATE II ' , PERMIT INSPECTION HISTORY REPORT (CBR2017•1557) ~, '" { ~ Permit Typt> BLDG-Residential Application Date: 0711212017 Owner: Work Cl;::iss: Addition Issue Date: 11109/2017 Subdivision: Status Closed -Finaled Expiration Date: 0512012019 Address: IVR Number: 4950 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 11/19/2018 11/19/2018 BLDG-Fina! Inspection 11/20/2018 11/20/2018 BLDG-Final Inspection November 20, 2018 076478-2018 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 076604-2018 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Failed Tim Frazee COMMENTS GFCI on deck doesn't work and light, no stoop out bedroom Passed Tim Frazee COMMENTS GFCI on deck doesn't work and light, no stoop out bedroom PAISAN PINPOKINTR LA COSTA VALLEY UNIT# 1 2072 Mar Azul Way Carlsbad, CA 92009-6722 Re inspection Complete Reinspection Complete Passed No No No No No Complete Passed Yes Yes Yes Yes Yes Page 3 of 3 ' ,, '• q" PERMIT INSPECTION HISTORY REPORT (CBR2017-1557) I \ ' ' Pcrrnit Type· BLDG-Residential Application Date: 07/12/2017 Owner: PAISAN PINPOKINTR Work Class: Addition Issue Date: 11/09/2017 Subdivision: LA COSTA VALLEY UNIT# 1 Status: Closed -Finaled Expiration Date: 05/20/2019 Address: 2072 Mar Azul Way Carlsbad, CA 92009-6722 IVR Number: 4950 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 06/22/2018 06/22/2018 BLDG-13 Shear 068790-2018 Passed Tim Frazee Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-31 068791-2018 Passed Tim Frazee Complete Underground/Condu It-Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/02/2018 07/02/2018 BLOG-84 Rough 062866-2018 Paased Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07/11/2018 07/11/2018 BLDG-16 Insulation 063623-2018 Passed Paul Burnette Compk!te Checklist ltem COMMENTS Passed BLDG-Building Deficiency Yes 07/26/2018 07/26/2018 BLDG-17 Interior 064641-2018 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-18 Exterior 064642-2018 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 09/27/2018 09/27/2018 BLDG-12 Steel/Bond 071272-2018 Passed Paul Burnette Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency No 10/10/2018 10/10/2018 BLDG-66 Grout 072434-2018 Passed Andy Krogh Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Retaining wall Yes November 20, 2018 Page 2 of 3 . . . ·. . PERMIT INSPECTION HISTORY REPORT (CBR2017-1557) PrJrrnit Type: BLDG-Residential Application Dato: 07/12/2017 Owner: Work Class; Addition Issue Date: 11/09/2017 Subdivision: Status; Closed -Finaled Expiration Date: 05/20/2019 Address: Scheduled Actual Date Start Date -~------~~-"--- 11/13/2017 11/13/2017 12/18/2017 12/18/2017 12/27/2017 12/27/2017 01/18/2018 01/18/2018 01/30/2018 01130/2018 04/06/2018 0410612018 November 20, 2018 IVR Number: 4950 Inspection Type Inspection No. BLDG-SW-Pre-Con 040240-2017 Checklist Item BLDG-Building Deficiency BLDG-21 043663-2017 Underground/Underf loor Plumbing Checklist ltem BLDG-Building Deficiency BLDG-11 044398-2017 Foundatlon/Ftg/Pier s (Rebar) Checklist Item BLDG-Building Deficiency BLDG-12 Steel/Bond 044399-2017 Beam Checklist Item BLDG-Building Deficiency BLDG-24 048228-2018 Rough/Topout Checklist Item BLDG-Building Deficiency BLDG-11 047097-2018 Foundatlon/Ftg/Pier s (Rebar) Checklist Item BLDG-Building Deficiency BLDG-12 Steel/Bond 047098-2018 Beam Checklist Item BLDG-Building Deficiency BLDG-11 054130-2018 Foundatlon/Ftg/Pier s (Rebar) Checklist Item BLDG-Building Deficiency Inspection Status Primary Inspector Passed Paul Burnette COMMENTS Passed Tim Frazee COMMENTS Partial Pass Paul Burnette COMMENTS Partial Pass Paul Burnette COMMENTS Passed Tim Frazee COMMENTS Underground waste OK, put cap on main line no 4" weenie system full of water. Partial Pass Michael Collins COMMENTS Exterior footings, see card Paased Michael Colllns COMMENTS Exterior/interior spread footings, see revised drawing by EOR Passed Chris Renfro COMMENTS See card. Inspected grade beam footing for deck column supports, and footing for living room with (2) HDU8's. OK to pour. Still need special inspection report for Epoxy HD bolts. PAISAN PINPOKINTR LA COSTA VALLEY UNIT# 1 2072 Mar Azul Way Carlsbad, CA 92009-6722 Re inspection Complete Complete Passed Yes Complete Passed Yes Relnspection Incomplete Passed No Reinspection Incomplete Passed No Complete Passed Yes Reinspectlon Incomplete Passed No Complete Passed Yes Complete Passed Yes Paga 1 of 3 · {cicyof Carlsbad CIAL SPECT ON Development Services SPE IN I REci::rur-o Building Division AGREEMENT -,.c,:," '-• 1635 Faraday Avenue B-45 NOV O 9 2017 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following mi&Ubl:,lilHit/pltile!l'~etwork being performed requires special inspection, structural observation and construction material testing. Project/Permit R2D 17-I S-6 7 Project Address· 207 2. t--1or Aw I A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print,_) -~LL~-'-=· S=A,_,_N_c_ _______________ _,_]"-') N._,_.f_o_K'-"'-'/,v-'--'-{1C. __ (First) 1 (M.I.) (Last) ]14J 5t'rt f:l r,AthA-, e,.412 Lg 'BAX) cA 9'} ooq lam: roperty Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record State of California Registration Numbec.· _____________ Expiration Date: ________ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. ~2::":=-==~~-~~=-----Date I{/ '°I(//, 8. ATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder/ owner-builder. Contractor's Company Name: ___________________ Please check if you are Owner-Builder □ Name: (Please printl------,,-------------------------------(First) (M.I.) {Last) Mailing Address: ___________________________________ _ Email: _________________________ Phone: ___________ _ State of California Contractor's License Number: __________ Expiration Date: _______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final insoection. s~~ ~•_u«_;,_/_5.J,_/....L/lf_+---~ B-45 Page 1 of 1 Rev. 08/11 EsGil Corporation In (Partnersfiip witfi qovemment for (}Juilain9 Safety DATE: November 3, 2017 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-1557 PROJECT ADDRESS: 2072 Mar Azul Way SET: II □ APPLICANT IJ...d1'.J RI S. -/4 PLAN REVIEWER □ FILE PROJECT NAME: SFD Remodel & Gazebo for Paisan Pinpokintr & Miko Chiem [8l The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [8l EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contactee<!d,1..· __ _ Date contacted:---~(~~t1 ) Mail Telephone Fax In Person Telephone#: Email: [8l REMARKS: Special Inspection notes are found on sheet S-2 of the plans. By: Abe Doliente EsGil Corporation □ GA □ EJ □ MB □ PC Enclosures: 10/30/17 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 EsGil Corporation In <Partnersfiip witfi qovernment for <Buifaing Safety DATE: July 20, 2017 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-1557 PROJECT ADDRESS: 2072 Mar Azul Way SETi □ APPLICANT ~ JURIS. □ PLAN REVIEWER □ FILE PROJECT NAME: SFD Remodel & Gazebo for Paisan Pinpokintr & Miko Chiem D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Jeff Parshalle Architect D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Jeff Parshalle Telephone#: 619-985-9099 ~•a, een~e~~~7/'20/17 (by~) Email: jeff@jparch.net <...___J:::: ail Tele ho~ ax In Person 0 REMARKS:I 0-:fiF" By: Abe Doliente EsGil Corporation 0 GA O EJ O MB O PC Enclosures: 7/13/17 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2017-1557 July 20, 2017 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: CBR2017-1557 JURISDICTION: Carlsbad PROJECT ADDRESS: 2072 Mar Azul Way FLOOR AREA: Addition -267 SF Remodel -3637 SF Deck-201 SF Gazebo -690 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: July 20, 2017 FOREWORD (PLEASE READ): STORIES: 2 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/13/17 PLAN REVIEWER: Abe Doliente This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2017-1557 July 20, 2017 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Abe Doliente BUILDING ADDRESS: 2072 Mar Azul Way BUILDING OCCUPANCY: R3/U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Addition 267 169.50 Deck 201 20.03 Gazebo 690 26.20 Remodel 3637 46.51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance Bldg. Permit Fee by Ordinance • I Plan Chee~ Fee by ~~~~~CE:__ -~ Type of Review: 0 Complete Review D Repetitive Fee ~ Repeats D Other D Hourly EsGil Fee PLAN CHECK NO.: CBR2017-1557 DATE: July 20, 2017 Reg. VALUE ($) Mod. 45,257 4,026 18,078 169,157 236,517 $1,112.411 $723.071 D Structural Only $634.071 Comments: $90 In addition to the above fee, an additional fee of $45 is due ( 1 / 2 hour @ /hr.) for the CalGreen review. Sheet 1 of 1 macvalue.doc + Carlsbad CBR2017-1557 July 20, 2017 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring Tif.!.Q corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 2. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). • GENERAL RESIDENTIAL REQUIREMENTS 3. Sleeping rooms shall have a window or exterior door for emergency escape. Section R310. Windows D and G of bedrooms 1 & 2 do not qualify. Please revise plans to provide at least one emergency escape window or exterior door for bedrooms 1 & 2. a) Windows must have an open able area of at least 5. 7 square feet, with the minimum openable width 20" and the minimum openable height 24". b) The bottom of the clear opening shall not exceed 44" above the floor. Do not measure to the window sill. This generally applies to windows that have a height of 3' or less. See the figure below to see the correct method of measurement. 4. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in doors. Show or note this on the plans. Carlsbad CBR2017-1557 July 20, 2017 b) Glazing adjacent to a door where the nearest vertical edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" above the walking surface. Window b must comply. • EXITS, STAIRWAYS, AND RAILINGS 5. Guards (Section R312): This applies to the area between the family room and the stairway. a) Shall be installed along open-sided walking surfaces that are located more than 30" above the floor or grade below. b) Shall have a height of 42" (may be 34" along the sides of stairs). c) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". d) Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. 6. Open risers are only permitted if the opening between treads does not permit the passage of a 4" diameter sphere. Section R311. 7.5.1. 7. The walls and soffits of the enclosed usable space under stairs shall be protected on the enclosed side with ½-inch gypsum board. Section R302.7. 8. 9. • ROOFS/DECKS/BALCONIES Enclosed framing in wood exterior balconies and decks shall be provided with openings that provide a net free cross ventilation area not less than 1 /150 of the area of each separate space. CBC Section 2304.12.2.6, as amended by emergency building standards. Wood balconies and decks that support moisture-permeable floors shall be provided with an impervious moisture barrier system under the moisture- permeable floor, with positive drainage. CBC Section 2304.12.2.5, as amended by emergency building standards. • STRUCTURAL 10. Balconies and decks shall be designed for 150% of the live load required by Table 1607.1. CBC Table 1607.1, as amended by emergency building standards. Recheck beams FB-4 and FB-6. The deck live loads contribute to the loads applied to these beams. 11. Show FB-1 (W10X33) as called out on sheets 10-12 of the structural calculations. Refer to sheet S-4 of the plans. Carlsbad CBR2017-1557 July 20, 2017 12. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2). Use the attached Special Inspection form from the city. Also, delete the note below the Special Inspection on the cover sheet. See Structural Engineer's note on sheet S-2. a) Expansion anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. • ELECTRICAL 13. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If the service is over 200 amperes, submit a single line diagram, panel schedules, and provide service load calculations. 14. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.B(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 15. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.70(A). • PLUMBING 16. An instantaneous water heater is shown on the plans. Please include a gas pipe sizing design (isometric or pipe layout) for all gas loads. a) The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). • RESIDENTIAL GREEN BUILDING STANDARDS In addition to the notes already shown on the plans, include the following: 17. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1. Carlsbad CBR2017-1557 July 20, 2017 18. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. • ENERGY CONSERVATION 19. Electric Vehicle Charging: Note on the plans that electrical vehicle supply equipment (EVSE) rough-in only is required in one and two family dwellings and townhomes with attached garages. The EVSE rough-in consists of a minimum 1" conduit extending from the main panel to a junction box where the EVSE receptacle box will be provided. The main service panel must be sized to accommodate a future 208/240 Volt 40 ampere dedicated branch circuit. California Green Code 4.106.4. 20. Note or provide the following design requirements for gas water heaters installed to serve individual dwelling units: ES 150.0(n) a) Gas piping sizing based upon a minimum input of 200,000 btu/hr. b) A condensate drain installed no higher than 2" above the base of the heater that also allows for gravity drainage. c) The "B" vent installed in a straight position from the room containing the water heater to the roof termination. (For future possible sleeving for high efficiency heater venting.) d) A 120 volt receptacle accessible to the heater installed within 3'. 21. Instantaneous water heaters shall have isolation valves on both the cold and the hot water piping leaving the water heater complete with hose bibs or other fittings on each valve for flushing the water heater when the valves are closed. ES 110.3 22. All hot water piping sized ¾" or larger is required to be insulated as follows: 1" pipe size or less: 1" thick insulation, larger pipe sizes require 1 ½" thick insulation. Additionally, the ½" hot water pipe to the kitchen sink and the cold water pipe within 5' of the water heater are both required to be insulated. ES 150.00)2 23. When replacing or modifying the mechanical system: if applicable. o If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. o Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, it is not required at initial plan submittal. Carlsbad CBR2017-1557 July 20, 2017 • MISCELLANEOUS 24. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 25. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 26. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation. Thank you. Print Date: 04/19/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2072 Mar Azul Way BLDG-Permit Revision 2151304800 $0.00 Revision Permit Work Class: Residential Permit Revision Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: CBR2017-1557 Plan Check#: Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Ccityof Carlsbad Permit No: PREV2018-0044 Closed -Finaled 02/21/2018 03/15/2018 11/21/2018 PBurn Description: PINPOKINTR: STRCUTURALAND ARTICETURAL CHANGES TO WINDOWS, FRAMING, ROOF & FOUNDATION Applicant: JEFF PARSHALLE ARCHITECT JEFF PARSHALLE Po Box 230132 ENCINITAS 92023 619-985-4099 FEE Owner: PAISAN PINPOKINTR PAISAN PlNPOKINTR 7143 Sitio Bahia CARLSBAD, CA 92009-2043 760-207-3556 MANUAL BUILDING PLAN CHECK FEE Total Fees: $262.50 Total Payments To Date: $262.50 Balance Due: Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov AMOUNT $262.50 $0.00 · (cityof Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number C/3/4. 2-ot 7 . /s>7 Plan Revision Number PR[Jf;){)/ 7-oot/4 Project Address --=~_7_Z-_~/1t.~',1Tl~--'--if~7-_v.~t-~~f,,/_H __ .,_1 ________________ _ General Scope c/(Revision)!Deferred Submittal: _._/11,-'-"-I/V-='CLC~'--"/t-=.::-=lrV'--Lµ-=--=v/.'-"~'--'/_o-'--rJ__,_, _,tP<lc__c_/,.✓._'P...co_c_v'./ ___ _ kv1 ~/()/'/ '-. T?-i #v/ S /0/V, Foo/\J 1241'1 cW fe ///S/dN, ~c::.:: fe (J/ s /oAS. F > > CONTACT INFORMATION: Name_J.~e.=-'--''ff'---.,f-,P,~'/l~,1!,~J"r;~l/?#_UL ___ Phone vlt· "/8,· .fof? Fax~-------- Address ,P. ~ · e";( 7 'SO /~ ::Z I Email Address J'e f e j/A red. 11e/ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: ~ Plans [}f" Calculations D Soils D Energy D Other 2. Describe revisions in detail l'("fN C1171'N(J:e 01/N(Jd.., C If/IN <,p$ W tAI (J<) i,J 771/e µvi J'i,/11 T j,f µ111,s-,-o,-.Jf:° n ur! P />-11 6,..; $,~I/lb/UV f't-,1/L r /A /J'1 I ,U c; #-v' (.JI 11,11 > ~/>1/IUu:, ,t}.pfftC-e,f:-r/ I J" ~ fb v/\1' /J lr'n • ,J ~~l-µv1s-1,JJf 4. 7o~:~his'reirlfion:· i; any way, alter the exterior of the project? 5. Does this revision add ANY new floor area(s)? D Yes 6. Does this revision affect any fire related issues? D Yes 7. es D No ffi"Yes G?°'No [i6' No Date 3. List page(s) where each revision is shown ,?•'J.,O ,?--i..( 11 -{"." TH 5g S-Ff S"fi '.l, S/J I ;>.?Jd1 No ,€$'Signature 1635 Faraday Av Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov CBR2017-1557 2072 Mor Azul Way Construction Change (Delta 1 21 The scope of the change includes modifications to the following drawings: A2.0 -Living Room plan change A2.1 -Window changes A5.0 -Window type revisions T24 -Window revisions S3 -Foundation revisions S4 -Floor framing revisions S5 -Roof framing & header revisions SD-2 -Framing detail revisions SD-4 -Foundation detail revisions Jeff Parshalle Architect C 11757 iell porshalle architect po box 230132 encinilas ca 92023 ,• ✓• EsG1I A SAFEbullt Company DATE: March 2, 2018 JURISDICTION: Carlsbad □ Af"'PLICANT Gl/1URIS. PLAN CHECK#.: CBR2017-1557 Rev (Prev2018-0044) ___ SETI PROJECT ADDRESS: 2072 Mar Azul Way PROJECT NAME: SFD Remodel for Paisan Pinpokintr & Miko Chiem □ □ □ □ □ ~ □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ~ Date contacted: ~ Telephone#: (by@; ) Email: Mail Telephone Fax In Person REMARKS: Revision includes addition of fireplace, framing changes and window changes. By: Abe Doliente EsGil 2/23/18 Enclosures: Original set of approved plans. 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 '• •' Carlsbad CBR2017-1557 Rev (Prev2018-0044) March 2, 2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad (Prev2018-0044) PLAN CHECK#.: CBR2017-1557 Rev PREPARED BY: Abe Doliente BUILDING ADDRESS: 2072 Mar Azul Way BUILDING OCCUPANCY: R3/U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ------... 1997 UBC Building Permit Fee _ __I 1997 UBC Plan Check Fee ----~ Type of Review: □ Complete Review D Repetitive Fee -,..1 Repeats ... .I * Based on hourly rate Comments: D Other [J Hourly EsGil Fee DATE: March 2, 2018 Reg. VALUE ($) Mod. $262.501 D Structural Only 21 Hrs.@* ~=====$=1 o=s=. o~o $210.001 Sheet 1 of 1