Loading...
HomeMy WebLinkAbout2075 CORTE DEL NOGAL; P; CB040214; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB040214 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2075 CORTE DEL NOGAL CBAD St P Tl Sub Type 2130610700 Lot# $169 290 00 Construction Type Reference # CALSENSE-5643 SF-COMBINE SUITE OP&Q TO ONLY SUITE P COMM 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# ISSUED 01/20/2004 MEL 05/20/2004 05/20/2004 Applicant MARK MCKINNEY STEP 6564 CONEFLOWER 92009 760804-1383 Owner SAN-GAL TRUST 550 WCST #1820 SAN DIEGO CA 92101 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $76216 Meter Size $0 00 Add'l Reel Water Con Fee $495 40 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $35 55 PFF $0 00 PFF (CFD Fund) $0 00 License Tax $0 00 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $41 00 $2000 $4200 $000 $000 $000 $000 $1,39611 Total Fees $1,396 11 Total Payments To Date $495 40 Balance Due $900 71 2o28 05 '20' l* D0'"2 01 12 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1 PROJECT INFORMATION ,: l-oO'S £Qn-V& O^L. Address (include Bldg/Suite #) FOR OFFICE USE ONLY PLAN CHECK NO EST VAL PlanCk Deposit Validated By ' Date Business Name (at this address) Legal Description Lot No Subdivision Name/Number UnTf'No 31 ."J.fihase N»/\A1 riTotal # of'umts-*•-» w i/i •»_>_'/ w-t _i/\.'«_ _r_ •„ a. /Q«r Description of Work # of BathTooims 2 CONTACT PERSON (if different from applicant) I \JlT <^^~^ * *"*^ __!„!__ t * / Address City | Contractor d Agent for Contractor, Q Owner md Agent for Owner Name :3 ;NI APPLICANT State/Zip Telephone #. Fax Name 4 PROPERTY OWNER Address City State/Zip Telephone Name 5 CONTRACTOR Address City State/Zip Telephone # COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001) Name State License #451 &1 Address License Class _ City State/Zip City Business License ft /' Telephone # ,2-^3 gn Address City State/ZipDesigner State License 6 WORKERS Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~l I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued ^l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company ,—^"farbfc. |)-<»«*/>dt^ Policy No £)C'{~*^'' C*&~ J*^*^' Expiration Date l~l~~&£> (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) n CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to thjXvorkeryCompensation Laws of California WARNING Failur&Jjrsefllire vfnVers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($9QpVuO) inlaodltion yxthe cost of compensation damages as provided for in Section 3706 of the LaJ>6> code interest and attorney s fees SIGNATURE M,1^^^I^JU>t9)' ~'" DATE 7 OWNER B^ILDE^TDECLAR I hereby affirm that I ar^exemgjarom the Contractor s License Law for the following reason d I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) d I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES flNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY f- S " *!• 1 ... ™; "'. Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? d YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? l~l YES l~1 NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? f~1 YES l~| NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 CONSTRUCTION LENDING AGENCY ; _ > Pi ih if I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER S NAME _ LENDER S ADDRESS _ 9 'ii APPLICANT CERTIFICATION ' ...... ":' .............. «:| ""H , 'U^f^ ...... • ..... ""J. ,:«:••• ,::.. ................. I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180\jays (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE \A/W^ l^ /X^OwL^ DATE [ ?~& <* 4" _ WHITE FilK \YELLOW Applicant PINK Finance City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Plan Check # Permit* CB040214 Project Name CALSENSE-5643 O.P&Q TO ONLY SF COMBINE SUITE SUITE P Address 2075 CORTE DEL NOGAL #P Contact Person DAVE Sewer Dist CA Inspected ^ ,./? Bv rT y^-^f^- — -, f Inspected Bv Inspected Bv Comments Phone 760497841 1 Water Dist CA Date / / Inspected '/tf/0 / Date Inspected Date Inspected • • • . ...•• Lite <^Fl?e Date 06/29/2004 Permit Type Tl Sub Type COMM Lot 0 Approved Disapproved Approved Disapproved Approved Disapproved • • • Inspection List Permit* CB040214 Type Tl Date Inspection Item 12/01/2004 89 12/01/2004 89 11/23/2004 89 11/23/2004 89 11/22/2004 89 11/22/2004 89 10/13/2004 89 09/20/2004 14 09/20/2004 24 09/20/2004 34 09/20/2004 44 08/30/2004 17 08/25/2004 14 08/25/2004 34 08/24/2004 14 08/24/2004 34 07/30/2004 14 07/30/2004 34 07/30/2004 44 07/14/2004 17 07/13/2004 17 07/09/2004 14 07/09/2004 34 06/29/2004 89 06/14/2004 84 06/11/2004 84 06/01/2004 17 06/01/2004 24 05/26/2004 14 05/26/2004 24 05/26/2004 34 05/24/2004 84 Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Boltmg/Weldin Rough Electric Frame/Steel/Boltmg/Weldin Rough Electric Frame/Steel/Bolting/Weldm Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Weldm Rough Electric Final Combo Rough Combo Rough Combo Interior Lath/Drywall Rough/Topout Frame/Steel/Boltmg/Weldin Rough/Topout Rough Electric Rough Combo COMM Inspector Act RB TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP RB PY RB RB TP TP TP TP TP TP TP TP PS AP Rl Rl NR Rl CA CO AP AP AP AP AP AP AP CO CO AP AP AP AP CA AP AP CA CO CA AP AP AP NR AP CO CALSENSE-5643 SF-COMBINE SUITE O.P&Q TO ONLY SUITE P Comments no plans/card PER OFFICE NOTICE ATTACHED T-CEIL (SEE CARD) CEILLITES DUCTS PHS III WALLS LOBBY SOFFIT PHS III WALLS, LOBBY SOFFIT NPP, WOOD STUDS SPEC T CEIL PHS II CEIL LITES PHS II DUCTS PHS II PHASE 2 WALLS WALLS PHS 2 WALLS PHS 2 PER CONT NPP GRIDSUPP RESET FOR MONDAY 1ST PHS 1ST PHS PHS 1 WALLS PHS 1 WALLS NOT PER PLANS PLANS SHOW WOOD WALL INSTALLED METAL Thursday, December 02 2004 Page 1 of 1 City of Carlsbad Bldg Inspection Request For 12/01/2004 Permit* CB040214 Title CALSENSE-5643 SF-COMBINE SUITE Description 0,P&Q TO ONLY SUITE P Inspector Assignment TP Type Tl Job Address Suite Location OWNER SAN-GAL TRUST Owner SAN-GAL TRUST Remarks Sub Type COMM 2075 CORTE DEL NOGAL P Lot 0 Phone 7604978411 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By DAVE Entered By CHRISTINE omment Associated PCRs/CVs Inspection History Date 11/23/2004 11/22/2004 10/13/2004 09/20/2004 09/20/2004 09/20/2004 09/20/2004 08/30/2004 08/25/2004 08/25/2004 08/24/2004 08/24/2004 07/30/2004 07/30/2004 07/30/2004 07/14/2004 Description 89 89 89 14 24 34 44 17 14 34 14 34 14 34 44 17 Final Combo Final Combo Final Combo Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Frame/Steel/Bolting/Welding Rough Electric Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Act NR CA CO AP AP AP AP AP AP AP CO CO AP AP AP AP Insp TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP RB Comments no plans/card PER OFFICE NOTICE ATTACHED T CEIL (SEE CARD) CEIL LITES DUCTS PHS III WALLS LOBBY SOFFIT PHS III WALLS LOBBY SOFFIT NPP WOOD STUDS SPEC T CEIL PHS II CEIL LITES PHS II DUCTS PHS II PHASE 2 WALLS City of Carlsbad Bldg Inspection Request For 10/Pfi72004 Permit* CB040214 Title CALSENSE-5643 SF-COMBINE SUITE Description 0,P&Q TO ONLY SUITE P Inspector Assignment TP 2075 CORTE DEL NOGAL P Lot 0 Type Tl Job Address Suite Location APPLICANT MARKMCKINNEY Owner SAN-GAL TRUST Remarks Total Time Sub Type COMM Phone 7604978411 Inspector Requested By DAVE Entered By CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Associated PCRs/CVs Date 09/20/2004 09/20/2004 09/20/2004 09/20/2004 08/30/2004 08/25/2004 08/25/2004 08/24/2004 08/24/2004 07/30/2004 07/30/2004 07/30/2004 07/14/2004 07/13/2004 07/09/2004 07/09/2004 Inspection History Description 14 24 34 44 17 14 34 14 34 14 34 44 17 17 14 34 Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Frame/Steel/Bolting/Welding Rough Electric Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Act AP AP AP AP AP AP AP CO CO AP AP AP AP CA AP AP Insp TP TP TP TP TP TP TP TP TP TP TP TP RB PY RB RB Comments T CEIL (SEE CARD) CEIL LITES DUCTS PHS III WALLS LOBBY PHS III WALLS LOBBY SOFFIT SOFFIT NPP WOOD STUDS SPEC T CEIL PHS II CEIL LITES PHS II DUCTS PHS II PHASE 2 WALLS WALLS PHS 2 NOTICECITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE '<?//£/£•¥ TIME LOCATION PERMIT NO / ~\\ -ZZs^s ^sCSAStrtt /2/r£& tz-e-d A^ch* J^l FOR INSPECTION CALL (760) 602 2725 RE INSPECTION FEE DUE? i > YES FOR FURTHER INFORMATION CONTACT ~~? PHONE / ~"^^^ BUILDING INSPECTOR CODE ENFORCEMENT OFFICER © EsGil Corporation In Partnership -with government for (BmUing Safety DATE 5/17/04 a APPLICANT O-^ttJRTS^ JURISDICTION City of Carlsbad b~FtAN REVIEWER a FILE PLAN CHECK NO O4-O214 SET IV PROJECT ADDRESS 2075 Corte Del Nogal PROJECT NAME Calsense - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person A] REMARKS Applicant to slip sheet the revise sheets 1 and 2 to City held sets By Doug Moody •• Enclosures Esgil Corporation ' D GA D MB D EJ D PC 5/10/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858) 560-146?1 * Fax (858) 560-1576 EsGil Corporation In (Partners Rip with government for Quitting Safety DATE 5/3/04 a APPUCANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-214 SET III PROJECT ADDRESS 2075 Corte Del Nogal PROJECT NAME Calsense - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck |/<] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person [XI The applicant's copy of the check list has been sent to Mark McKinney 6564 Coneflower Dr, Carlsbad, CA 92009 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mark McKinney Telephone # 760-804-1383 Date contacted <S/3/OH (by f-A>c) Fax # 760-804-2758 Mail -"Telephone Fax */ In Person ] REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 4/20/04 tmsmUdot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O4-214 5/3/04 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO 04-214 PROJECT ADDRESS 2075 Corte Del Nogal SET III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 4/20/04 5/3/04 REVIEWED BY Doug Moody FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes LlNo City of Carlsbad 04-214 5/3/O4 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue 1 Each sheet of the plans must be signed by the person responsible for their preparation even though there are no structural changes Business and Professions Code THE FINAL PLANS WILL BE CHECKED FOR THIS REQUIREMENT No Response 4 Identify existing walls to be removed existing walls to remain and proposed new walls Identify bearing walls non-bearing waiis and shear waiis THERE ARE VARIOUS WALLS THAT ARE SHOWN TO HAVE NEW OPENINGS IN THEM (OF PARTICULAR INTEREST, THE PREVIOUS DEMISING WALLS) IT MUST BE SHOWN ON THE PLANS WHETHER THOSE WALLS ARE BEARING/SHEAR WALLS IF THEY ARE, THEN PROVIDE COMPLETE STRUCTURAL DETAILING A DESIGN FOR THE NEW OPENINGS IN THEM Please provide the calculations, plans and details 15 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the rooftop air handler units Include all calculations and finding on the plans Please include the California license number seal date of license expiration and date plans are signed Business and Professions Code YOU STATED THAT THE EQUIPMENT WILL BE IN THE SAME LOCATIONS AS THE EXISTING EQUIPMENT PLEASE SPECIFY THIS ON THE PLANS Please provide evidence the roof was designed to support the weight of the new equipment The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGil Corporation In Partnership vntfi. government for 'Bw.lding Safety DATE 4/19/04 'JURJj JURISDICTION City of Carlsbad DfPLAN REVIEWER Q FILE PLAN CHECK NO 04-214 SET II PROJECT ADDRESS 2075 Corte Del Nogal PROJECT NAME Calsense - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes [~1 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck [ | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person 1X1 The applicant's copy of the check list has been sent to Mark McKmney 6564 Coneflower Dr, Carlsbad, CA 92009 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed [X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mark McKmney Telephone # 760-804-1383 Date contacted ^l/^/oH (byf*^) Fax # 760-804-2758 Mail«—'Telephone Fax^ In Person REMARKS By Doug Moody (by KC) Enclosures Esgil Corporation D GA D MB D EJ D PC 4/12/04 tmsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego California 92123 * (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 04-214 4/19/04 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO 04-214 PROJECT ADDRESS 2075 Corte Del Nogal SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 4/12/04 4/19/04 REVIEWED BY Doug Moody (by KC) FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list7 QYes QNo City of Carlsbad O4-214 4/19/O4 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation even though there are no structural changes Business and Professions Code THE FINAL PLANS WILL BE CHECKED FOR THIS REQUIREMENT 2 Please indicate on the plans the area of the mezzanine and the scope of work for demolition PLEASE SPECIFY THE ACTUAL FLOOR AREA OF THE MEZZANINE THAT WILL BE DEMOLISHED 4 Identify existing walls to be removed existing walls to remain and proposed new walls Identify bearing walls non bearing walls and shear waiis THERE ARE VARIOUS WALLS THAT ARE SHOWN TO HAVE NEW OPENINGS IN THEM (OF PARTICULAR INTEREST, THE PREVIOUS DEMISING WALLS) IT MUST BE SHOWN ON THE PLANS WHETHER THOSE WALLS ARE BEARING/SHEAR WALLS IF THEY ARE, THEN PROVIDE COMPLETE STRUCTURAL DETAILING A DESIGN FOR THE NEW OPENINGS IN THEM 8 If exit signs are required provide the following notes on the plans per Section 1003 2 8 2 Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign Exit signs shall be readily visible from any direction of approach THESE NOTES COULD NOT BE FOUND ON THE PLANS 11 Please have the document author and the principle designer of the LTG 1 form sign the imprinted document NOT DONE 12 Please revise the LTG 2 to show the correct floor area NOT DONE 13 Please revise the LTG forms to show area category method of compliance the entire buildings lighting must be shown if complete building method is to be used NOT DONE City of Carlsbad 04-214 4/19/04 1 5 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the rooftop air handler units Include all calculations and finding on the plans Please include the California license number seal date of license expiration and date plans are signed Business and Professions Code YOU STATED THAT THE EQUIPMENT WILL BE IN THE SAME LOCATIONS AS THE EXISTING EQUIPMENT PLEASE SPECIFY THIS ON THE PLANS 21 Please imprint on the plans the ENV mandatory measures NOT DONE 22 When alterations structural repairs or modifications or additions are made to an existing building that building or portion of the building affected is required to comply with all of the requirements for new buildings per Section 1134B 2 These requirements apply as follows a) The area of specific alteration repair or addition must comply as "new" construction DOOR 9 IS NOW SHOWN ON THE FLOOR PLAN, BUT ITS NOT IN THE DOOR SCHEDULE 23 It is unclear from the plans if the restrooms servicing the tenant improvement are disabled accessible please provide a dimensioned restroom plans showing the restroom to be accessible compliant THERE IS A RESTROOM PLAN ON SHEET 7, BUT IT SEEMS TO CONFLICT WITH SHEET 2 FIRST, THE RESTROOM DOORS DON'T SWING OUTWARD (WHICH IS NEEDED IN ORDER TO PROVIDE THE REQUIRED CLEARANCE OF 60" IN THE DIRECTION OF DOOR SWING) ALSO, SHEET 2 SHOWS THAT THE SINKS ARE VERY CLOSE TO THE WATER CLOSETS, SO THE CLEARANCE FROM SHEET 7 ISN'T PROVIDED 25 Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36 long and no more than 28 to34"high Section 1122B 4 WHETHER IT'S CALLED A DESK OR COUNTER, THE REQUIRED HEIGHT MUST BE PROVIDED IF IT'S A BUILT-IN UNIT To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list9 Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody (by KC) at Esgil Corporation Thank you EsGii Corporation In (Partnership with government for tBmfding Safety DATE 1/30/O4 Q APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-214 SET I PROJECT ADDRESS 2075 Corte Del Nogal PROJECT NAME Calsense - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Mark McKmney 6564 Coneflower Dr, Carlsbad, CA 92009 Esgil Corporation staff did not advise the applicant that the plan check has been completed 1X1 Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mark McKmney Telephone # 760-804-1383 Date contacted 1/35/04 (by ^) Fax # 760-804-2758 Mail Telephone-^ Fax ^In Person 1 REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 1/23/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 04-214 1/30/O4 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O4-214 OCCUPANCY B TYPE OF CONSTRUCTION VN ALLOWABLE FLOOR AREA SPRINKLERS'? Unknown REMARKS DATE PLANS RECEIVED BY JURISDICTION 11/21/04 DATE INITIAL PLAN REVIEW COMPLETED 1/30/04 JURISDICTION City of Carlsbad USE Office ACTUAL AREA 5643sf STORIES 1 HEIGHT OCCUPANT LOAD 73 DATE PLANS RECEIVED BY ESGIL CORPORATION 1/23/04 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list for a copy) where each correction item has been addressed, i e, plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad O4-214 1/30/04 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGi! Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Please indicate on the plans the area of the mezzanine and the scope of work for demolition 3 Please clarify the use of the classroom and indicate the occupancy and occupant load1? 4 Identify existing walls to be removed, existing walls to remain and proposed new walls Identify bearing walls, non-bearing walls, and shear walls 5 Please clarify the section view of all new interior partitions Show a) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing 6 Specify lever-type hardware for passage doors on floors accessible to the disabled Title 24 7 Exit signs are required whenever two exits are required Show all required exit sign locations Section 1003 282 8 If exit signs are required, provide the following notes on the plans, per Section 1003282 a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign b) Exit signs shall be readily visible from any direction of approach 9 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two City of Carlsbad O4-214 1/30/O4 family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 10 Show exit signs on the electrical lighting plan(s) As per Section 1003 2 8, provide two sources of power to exit signs and exit illumination 11 Please have the document author and the principle designer of the LTG-1 form sign the imprinted document 12 Please revise the LTG-2 to show the correct floor area 13 Please revise the LTG forms to show area category method of compliance the entire buildings lighting must be shown if complete building method is to be used 14 Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 15 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the rooftop air handler units Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code 16 Please indicate the location of the ladder access to roof mounted HVAC equipment 17 Provide complete plumbing plans, including a) Complete dram, waste and vent plans b) Provide water line sizing and developed pipe lengths UPC Section 610 0 c) Show water heater size, type and location on plans UPC, Section 501 0 18 Provide Separate Facilities for each sex as per UPC, Section 4133 19 Show 1/4" per 12" slope on dram and waste lines UPC Section 708 0 20 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design 21 Please imprint on the plans the ENV mandatory measures 22 When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) The area of specific alteration, repair or addition must comply as "new" construction City of Carlsbad O4-214 1/30/04 b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features 23 It is unclear from the plans if the restrooms servicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant 24 Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc 25 Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36" long and no more than 28" to 34" high Section 1122B 4 26 Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings, per Section 1133B 243 a) >24" at exterior conditions b) >18" at interior conditions c) >12" on the push side, if the door has both a latch and a closer Figure 11B-26A d) Where a door is located in a recess or alcove where the distance from the face of the wall to the face of the door is greater than 8 inches, the above clearances shall apply Section 1133B 245 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you CITY OF CARLSBAD POLICIES AND PROCEDURE 1UMBER 80-6 EFFECTIVE 5/1/92 SUPERSEDES 80-6(9/10/80) 80-6(5/01/81) SUBJECT ROOF MOUNTED EQUIPMENT SECTION BUILDING DEPARTMENT PURPOSE INTENT PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS A Maintain roof integrity B Prevent hazardous condition to Tirernen who must fight fire on the roof C Provide an installation that is aesthetically sensitive to the building and the adjoining properties POLICY 1 All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department 2 All equipment shall be specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department 3 All roof mounted equipment shall be on a platform which shall be an integral part or the roof-flashed and waterproofed Wnen a screen is approved, it shall have as few roof connections ss possible and be structurally adequate 4 All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official 5 Sewer vents shall be brought to one mam vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in genera! proximity 6 Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official 7. Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused openings properly sealed -to maintain roof integrity. *The architect should, through design, conceal the heatmg/AC unit and other equipment whether they are on the roof or elsewhere. initiated By:Approved B J- City of Carlsbad O4-214 1/3O/04 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 04-214 PREPARED BY Doug Moody DATE 1/30/04 BUILDING ADDRESS 2075 Corte Del Nogal BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 1004 HRr Riiilrlinrt Permit 1 AREA (Sq Ft) 5643 cb =PP W Valuation Multiplier City Valuation By Ordinance Reg Mod VALUE ($) 169,290 169,290 C7CO -1 C$/oz 1b 1994 UBC Plan Check Fee Type of Review I I Repetitive Fee—;-^-j Repeats GD Complete Review D Other •—I Hourly Structural Only Hour Esgil Plan Review Fee $495 40 $426 81 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS 1*1 ^ / RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000 00) DATE ii Co r ENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE ( Docs/Misforms/'Plannmg Engineering Approvals D D ban PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner _ APN Address Greg Fisher Phone (760) 602-4629- Qbf-cn Type of R/oject & Use _ Zoning y rA General Plan CFD (m/out) #_Date of participation Net Project Density T _1>"' Facilities Management Zone DU/AC Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit ) Legend Item Complete Environmental Review Required DATE OF COMPLETION Item Incomplete - Needs your action YES NO TYPE Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES_ CA Coastal Commission Authority7 YES_ N0_ NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 YES_ If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # NO Follow-Up Actions 1} Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed Inclusionary Housing Fee required YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Comp'eted7 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Site Plan d d d 1 Provide a fully dimensional site plan drawn to scale Show North S*TOW property lines easements, existing and proposed structures, streets, existing street improvements right of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Odd 2 Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines d d d 1 Applicability YES NO d d d 2 Project complies YES N0_ d d d Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope Required Required Required Required Required d d d 2 Accessory structure setbacks Front Required Interior Side Required Street Side Required Rear Required Structure separation Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown 3 Lot Coverage 4 Height 5 Parking Space Required Required Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments Correction #1 - Please show on Sheet 1 the total number of parking spaces provided and required on site for each use per Chapter 21 44 Correction #2 - Is there any proposed roof mounted equipment associated with this building permit7 If so, will the equipment be screened by an existing parapet wall or is new screening material required7 Please see the attached handouts for examples OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER ATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner Greg Fisher Address Phone (760) 602-4629 Type of project & Use U'VviU^ Net Project Density DU/AC Mil P-T""Zoning y SM General Plan f \^ Facilities Management Zone (S^ CFD (in/out) #_Date of participation Circle One Remaining net dev acres (For non-residential development Type of land used created by this permit _ ) Legend [>3 Item Complete l~l Item Incomplete - Needs your action Environmental Review Required YES _ NO _ TYPE _ DATE OF COMPLETION ___ Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO DATE TYPE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES_ CA Coastal Commission Authority7 YES N0_ NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402,1619)767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 YES_ If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # NO L% D D\i Follow-Up Actions 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed Inclusionary Housing Fee required YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed7 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Site Plan [3] d d 1 Provide a fully dimensional site plan drawn to scale Show North arrow property lines easements, existing and proposed structures, streets, existing street improvements riant of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) d d d 2 Provide legal description of property and assessor s parcel number Policy 44 - Neighborhood Architectural Design Guidelines D D D 1 Applicability YES NO D D D 2 Project complies YES NO D D d d D d d d ^djd d Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope Required Required Required Required Required 2 Accessory structure setbacks Front Interior Side Street Side Rear Structure separation 3 Lot Coverage 4 Height Required Required Required Required Required Required Required 5 Parking Space Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required _ Shown ____ Additional Comments Correction #1 - Please show on Sheet 1 the total number of parking spaces provided and required on site for each use per Chapter 21 44 Correction #2 - Is there any proposed roof mounted equipment associated with this building permit7 If so. will the equipment be screened by an existing parapet wall or is new screening material required7 Please see the attached handouts for examples fcgfe-Ag^fe- e^otprvuau.r C»-4.u^/ u3\,rtj_ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Carlsbad Fire Department 040214 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Date of Report Fire Prevention (760) 602-4660 Requirements Category 04/20/2004 Building Plan Reviewed by Plan Checker Job Name Job Address Name Address City, State Calsense Mark McKmney 6564 Cornflower Dr Carlsbad CA 92009 I Job # 040214 Bldg # CB040214 2075 Corte Del Nogal Ste orBldg No Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2M 3rd 040214 FDFile# Other Ag<=nr.y in Carlsbad Fire Department 040214 1635 Faraday Ave Carlsbad, CA 92008 Plan Review Requirements Category Date of Report Fire Prevention (760) 602-4660 Building Plan ,rt 01/28/200 Name Address City, State '4 Kevie) Mark McKmney 6564 Cornflower Dr Carlsbad CA 92009 wed by (ywti^ \ Plan Checker Job Name Job Address Job # 040214 Calsense 2075 Corte Del Nogal .Bldg # CB040214 Ste or Bldg No D Approved The item you have submitted for review has been approved The approval is based on plans, information and / or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Approved The item you have submitted for review has been approved subject to the Subject to attached conditions The approval is based on plans, information and/or specifications provided in your submittal Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards Incomplete The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards Please review carefully all comments attached Please resubmit the necessary plans and / or specifications to this office for review and approval Review FD Job # 1st 2nd 3rd 040214 FDFile# Other Agenr.y ID t Requirements Category Building Plan Requirement Pending 0501 Project Data Provide complete address and suite designation Provide building construction information indicating occupancy classification, type of construction, number of stories, aggregate square footage, occupant load, and description of intended uses Project data incomplete General notes should include notes for Fire Protection (Dept) Ensure that this building Non-sprinkled, or revise Requirement Pending 0516 A/S Design Sprinkler system design shall be in accordance with standards set forth by the National Fire Protection Association and UBC Standards 38-1 and 38-2 Permits are required prior to installation Plans, specifications and calculations shall be certified by a licensed fire protection engineer or other person deemed competent by the Chief, and submitted in the name of a licensed sprinkler contractor Warehouse buildings for which no specific use, occupant, product, activity or storage array has been identified, shall be protected by sprinkler system designed to deliver water at the rate of 45 gallons per square foot, throughout a 3000 square foot design area Automatic fire sprinkler system cahnges shall be required to be submitted as seperate submittal Requirement Pending 0518 Fire Extinguishers Required Provide one 2A10BC fire extinguisher for each 6000 square feet or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel Provide notes on the plans that the extinguisher will be provided Fire extinguishers shall be required to be installed at time of inspection Page 1 01/28/04 TITLE 24 REPORT Title 24 Report for: CALSENSE 2075 CORTE DEL NOGAL,SUITE O,P,Q CARLSBAD, CA 92009 Project Designer: Report Prepared By: HADI MAHZARI ENERGY CONSULTING GROUP 8015 BALBOA AVENUE SAN DIEGO, CA 92111 (858) 268-0660 Job Number: Date: 12/4/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards This program developed by EnergySoft LLC (415)883-5900 EnergyPro 3 1 By EnergySoft Job Number User Number 2984 sfr^^-' C^&&46*^0- V£ _ ((-go A 108 =>oa nark & Shirley McKinnea 760 804-2758 P-I TO Fax#. Re Date. Pages FACSIMILE «Den>«iic,s From the desK of NlarK McKINNEY Architect 6564 Coneflower Or Carlsoad CA 92009 Phone (760) 804-1383 Toll Free (877) 738-2893 Fax (760) 804-2758 Play 25 04 03 56a MflY-95-2004 13 23 Mark & Shirley McKinnea WHITE CONSTRUCTION 760 804-2758 p.2 760 931 1171 P 03x03 t CEILNS PACE OF EXISTING 6HEU. 0» 5/&1 GYPSUM FLOOR ) FURR-OUT PARTITION 3'=r-2>' Mark I Mc&nney. Archttect 6564 Coneflower Drive Carlsbad, CA 92009 TOTAL P 03 „ May 25 04 03 56a MflY-95-2004 13 22 Mark & Shirley McKinney WHITE CONSTRUCTION 760 804-2758 p 3 760 931 1171 P 02/03 ' 24' OC.' ' • STRUCTURE ABOVE 3-5/8' 25 QA. METAL STUD BRACING • B'H0' OC. 13 INSULATION OVER CEILING SUSPENDED CEILING SYSTEM NOTE SUSPENDED ACOUSTIC OR HARDLID CEILINGS EXCEEDING 144 8a FT NET AREA SMALL HAVE COMPRESSION STRUTS. STRUTS SMALL CONSIST OF 25 GA. METAL STUDS ATTACHED TO UNDERSIDE OF ROCF STRUCTURE TO CEILING GRID/CWARRWG CHANNEL SPACE STRUT • Q'-G* OC. JN BOTW DIRECTIONS AND 4'~0* FROM UUVLLS. 3-5/S' 25 <3A. METAL STUD& « 2'-0' */&' GTFSUM BD EACW SIDE. ATTACM1ENT PER I9ST tLBC TABLE 25A-<3 ICBO NO 3403P NOTE: ALL STUD UMLL FRAMING TO BE DOME PER CEMCO SPECIFICATIONS OR EOUAL PER ICBO REPORT NO 3403P METAL LINE OF FLOOR SLAB INTERIOR PARTITION w/ INSULATION y*r-0- Marie L Mcfonncy, Architect 6564 Coneflowcr Drive Carlebad CA 92009 4 SD POLICYHOLDER COPY COMPENSATION INSURANCE PO BOX 807 SAINJ FRANCISCO CA 94142-0807 FUND ISSUE DATE CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 01-01-2004 CITY OF CARLSBAD ATTN BUILDING DEPARTMENT 1635 FARADAY AVENUE CARLSBAD CA 92008 SD GROUP 000046 POLICY NUMBER 0008760-2004 CERTIFICATE ID 61 CERTIFICATE EXPIRES 01-01-2005 01-01-2004/01-01-2005 JOB ALL OPERATIONS This is to certify that we have issued a valid Workers' Compensation insurance policy in a form approved by the California Insurance Commissioner to the employer named below for the policy period indicated This policy is not subject to cancellation by the Fund except upon 30 days advance written notice to the employer We will also give you 30 days' advance notice should this policy be cancelled prior to its normal expiration This certificate of insurance is not an insurance policy and does not amend extend or alter the coverage afforded by the policies listed herein Notwithstanding any requirement term or condition of any contract or other document with respect to which this certificate of insurance may be issued or may pertain the insurance afforded by the policies described herein is subject to all the terms exclusions and conditions of such policies AUTHORIZED REPRESENTATIVE PRESIDENT EMPLOYER'S LIABILITY LIMIT INCLUDING DEFENSE COSTS $1,000 000 00 PER OCCURRENCE ENDORSEMENT #2065 ENTITLED CERTIFICATE HOLDERS' NOTICE EFFECTIVE 01-01-2004 IS ATTACHED TO AND FORMS A PART OF THIS POLICY EMPLOYER LEGAL NAME WHITE CONSTRUCTION 5937 DARWIN CT STE 100 CARLSBAD CA 92008 S P WHITE CONSTRUCTION INC (REV 3 03) THIS DOCUMENT HAS A BLUE PATTERNED BACKGROUND PRINTED. 12-^-2003