HomeMy WebLinkAbout2075 LAS PALMAS DR; ; CB052513; Permit (2)&. . ~~ City of Carlsbad
,,, C'\.,, 1635 Faraday Av Carlsbad, CA 92008
08-25-2005 V Commercial/Industrial Permit Permit No: CB052513
Building Inspection Request Line (760) 602-2725
Job Address: 2075 LAS PALMAS DR CBAD
Permit Type: Tl Sub Type:
Parcel No: -2130611900 Lot #:
Valuation: $215,730.00 Construction type:
Occupancy Group: Reference #:
Project Title: CYGNUS
7,191 SF OFFICE TO OFFICE
INDUST
0
NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Applicant: Owner:
MOELLER KIRK
STE 100
5838 EDISON PLACE
CARLSBAD 92008
760 431-7775
Building Permit
Add'I Building Permit Fee
Plan Check '
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD#2Fee
BTO #3 Fee
Rc;mewal Fee
Add!I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter'Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$903.84
$0.00
$587.50
$0.00
$0.00
$45.30
$0.00
$0.00
$0.00
$0.00
$0.00
$0'.00
'$0.00
$0.0b
$0.00
$0.00
$0.0\)
CITY OF CARLSBAD
PUBLIC AGl;:NCY 00000
Meter Size
Add'I Reel. Water Con. Fee
Meter·Fee
SDCWAFee
CFD Payoff Fee
P_FF (31 O;i540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
traffic Impact Fee (3105541)
traffic Impact Fee ( 4305541)
PLUMBING TOTAL
EL,f;CTRICAL TOT AL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
. Additional Fees
TOTAL PERMIT FEES
ISSUED
07/06/2005
MDP
08/25/2005
08/25/2005
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$110.00
$78.00
$0.00
$0.00
$0.00
$0.00
$1,724.64
· Total Fees: $1,724.64 Total Payments To Date: $601.51 Balance Due: $1,123.13
ln~pector: ~
BU . DING P_L,i-1,.1 ... k i IN STORAGE .:S~(le.J>
-ATTACHED
FINAL APPROVAL
Date: lf?IWU r
5445 08./25/05 00{)2 01
CGP
Clearance: _____ _
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exaciions." You have 90 days fromthe date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the-protest procedures set.forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
02
1123-13
J\s~<£ .
PERMIT APPLICATION
:i 2028 07/06/05 0002 01 02
601-51
Lot No. Subdivision Name/Number Unit·No. ·Phase No. Total # of units
. Proposed Use tJFP!t.?
# of Bedrooms # of Bathrooms
Designer Name Address City State/Zip Telephone
State License# _________ _
~~~~:,~ }b'PBW~~s!-.qQM~~t.1-~TJQ.tti~-:: :~:~.:-~q~--A_ =::r~:A·~~.N<::_:~-::::::~~N-:::-~~-. ::_---::::~~: l~~Z':Zs:~3J?I~;~-;:; s>~;:~~ ~~;::s~2-:~~:P.:7::2:~7:::~~A~·{·; ?::-:;1~~~:r-=:~~:,~::; .;
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
0 1-have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
--..I issued. Myworker'sc pe sation,.'.'.1surancecarriera dpolicynumberare:--.._} ~/ /) (']"2Q"~' / r //!
J'-Insurance Company I'!-. P Policy No. 0~ '""Vl\:? 'b JU"f-><-Expiration Date / ~ 2??0f-,
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) ;/
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
·, __.,thousand dollars 00,000), in additi n t the cost mpensation, damages as provided for in Se ·on 06 of the Lab r code, in erest,!!!_d attorney's fees.
--1' SIGNATURE'"'*""-.J..(2.2::'.~~~2!:__----1-~~:::J::::::==__.,:;Z.=-------~.J DATE ---llt'----"'""--'"4-'--~'-1..-.-L-
[~.' '.J:qw']ifM!UJ :.Jl[Pl(t{~lf..4:t.(o.'ft .. ,-:_'.'.·: _,_ '" --,,;., -~·, .. , ........::, __ .::,-_,._ ·,. Nr:.,:,.,,,-w, ,._
I hereby affirm that I am exempt from the Contn!ctor's License for-the following-reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply·to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of-proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds· or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of.the proposed property improvement. 0 YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted.with the following person (firm) to provide the-proposed construction (include name/ address/ phone number/ contractors license number):
4. I plari to provide portions of the work, but I have hired the following person_ to coordinate, supervise and provide the majo'r work (include name / address / phone
number/ contractors license number)=----~----------~------------------------------
5. I will provide some of the work, but I have contracted {hired) the following persons to provide the work indicated (include name/ address / phone number/ type
of work)=--------------------~------------~----------------------
PROPERTY OWNER SIGNATURE
lcOJVIP~l;J"EJTHlS}SFQlJON ,F,Q...R.;.,N'::o:;:N;:;•R:;'E.:;:'S,:::10==:EJ:::'N=:n:-:!A:;L,::::;L::--;U:;IL::D:;IN;::@;:;,p;;e=RM'.7::· ::::IT-:;:;S;:::;O:::;N;::1:.Y:;~, ,:;-c:;:_;_;:;:;:;:::;:; ,· ~::::,::-:_ ::::-::;::-;:::::;:=;:, .. ,,,:;.",;,;:~~:=.;;;;;;:;:;;;::::;;::;;;:;:-;:::=::::;::,,,.,-;~\l
Is the applicant or future building occupant required to submit a business plan,. acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO
Is the applicant cir future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
Is the facility to b!l•Construi:ted within 1,000 feet of the outer boundary of a school site? 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
. REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
@:QieQN'STRUJ:~Tl(}N;~,END}Nff:GEJ(*;f;f'"\:::-::rir:::·5--:~:xr :::--~::::~ -~--~·": ...
I hereby affirm that there is a construction lending agency for the performance-of the work for which this permit is issued (Sec. 3097(i) Civil Code).
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA. permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commence within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commen r a eriod of 180 days (Section 106.4.4 Uniform Building Code). • //
APPLICANT'S SIGNATURE , ' DATE ~-~-JI,__ ~h~~~-_l)_b ______ _
WHITE: File YELLOW: Applicant PINK: Finance
111111 c1r11ll1d
~ Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite ~
Plan Check#:
Permit#:
Project Name:
08052513
CYGNUS
7,191 SF OFFICE TO OFFICE
Address: 2075 LAS PALMASDR
Contact Person: DOUG Phone: 7608454554
Sewer Dist: CA Water Dist: ·CA
Date:
Permit Type:
Sub Type:
Lot: 0
09/30/2005
Tl
INDUST
..........................................................................................................................................................
Inspected. flt~----~--. Date I CJ j <1-/"~ ~
By:_: ( __ _ !.':'J ~~-__,_.-'--. --,-Inspected: --2+Z~ Approved: __ Disapproved: __
Inspected Date
By:~----~-----~ Inspected: _____ Approved: ___ Disapproved: __
Inspected Date
By: Inspected: ______ Approved: ___ Disapproved: __ .......................................................................................................................................................... ,
Comments: ---------------------------------
City of Carlsbad Bldg Inspection Request
For: 10/03/2005
Permit# CB052513
Title: CYGNUS
· Inspector Assignment: TP
Description: 7,191 SF OFFICE to OFFICE
Type: Tl
Job Address:
Sub Type: INDUST
2075 LAS PALMAS DR
Suite: Lot
Location:
APPLICANT MOELLER KIRK
Owner: CITY OF CARLSBAD
Remarks: ROLLED FROM FRIDAY
Total Time:
CD Description
0
Act Comment
---
Phone: 7608454554
Inspector: ~
Requested By: DOUG
Entered By: JANEAN
19
29
39
Final Structural
Final Plumbing ·
Final Electrical
/lL ________________ _
i=~-
49 Final Mechanical
Associated PCRs/CVs
CV030693 CLOSED
C'./050740 CLOSED
0-ABANDONED CAR IN PRKNG LOT;
Z-ABANDONED VEHICLE;
CV990092 CLOSED ABANDONED VEHICLE;
PCR01124 ISSUED MODETEK-REVISE MECH PLAN;
Inspection History
Date Description Act lnsp Comments
09/30/2005 89 Final Combo NS TP FROM FRIDAY
09/22/2005 14 Frame/Steel/Bolting/Welding AP TP T-CEIL
09/22/2005 19 Final Structural WC TP
09/22/2005 34 Rough Electric AP TP CEIL LITES
09/22/2005 44 Rough/Ducts/Dampers AP TP DUCTS, PLUMS
09/20/2005 14 Frame/Steel/Bolting/Welding AP TP T-CEIL 1-4 LN.
09/20/2005 24 Rough/Topout WC TP
09/20/2005 34 Rough Electric AP TP CEIL LITES 1-4 LN.
09/20/2005 44 Rough/Ducts/Dampers AP TP DUCTS, PLMNS 1-4 LN.
09/02/2005 17 Interior Lath/Drywall AP RB COMPLETED
09/02/2005 44 Rough/Ducts/Dampers WC RB
08/31/2005 17 Interior Lath/Drywall AP TP CLN. RM. SECT. OFFICES, INFILLS
08/29/2005 14 Frame/Steel/Bolting/Welding AP TP WALLS
City of Carlsbad Bldg hispection Request
For: 10/03/2005
Permit# CB052513 Inspector Assignment: TP ---
08/29/2005 34 Rough Electric AP TP
08/26/2005 14 Frame/Steel/Bolting/Welding co TP
08/26/2005 14 Frame/Steel/Bolting/Welding co TP BRACING
08/26/2005 24 Rough/Topout WC TP
08/26/2005 34 Rough Electric AP TP WALLS
08/26/2005 44 Rough/Ducts/Dampers WC TP
-EsGil Corporation
In·<Partnersli.ip -witli. qovernment for <Bui(aing Safety
DATE: 8/29/05 CJ faPPl:+Cf.NT
CJ ~
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: -05-2513 SEr:11
CJ PLAN REVIEWER
CJ FILE
PROJECT ADDRESS: 2075 Las Palmas Dr
PROJECT NAME: Cygnus -TI
D
D
D
D
D
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The -plan_.s transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. ~
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not ·advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that th~ plan check has been completed.
2
Person contacted: Telephone #:
Date contacted: (by: ) Fax#:
Mail Telephone Fax In Person
[SI REMARKS: Per Mike -Peterson the plans are to be returned to the City of Carlsbad and city
staff will resblve the remaining items with the applicant.
By: Doug Moody
Esgil Corporation
D GA D MB D f:J D PC
Enclosures:
LOG tinsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In ~artnersfiip witli qovemment for (JJuiUing Safety
DATE: 8/23/05
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 05-2513
PROJECT ADDRESS: 2075 Las Palmas Dr
PROJECT NAME: Cygnus -Ti
SET: II
D APPLICANT ~ D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply·
with the jurisdiction's building codes.
D The plans transmitted .herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
~md should be corrected and resubmitted-for a complete recheck.
·~ The check list transmitted herewith is for your information. The plans are being held at Esgil
. Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
McArdle and Associates / Kirk Moeller
5838 Edison Place Suite 100, Carlsbad, -CA 92008
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
~· Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Kirk Moeller Telephone#: 760-431-7775
Date contacted: &f2alcS(by:F-Ay). Fax #: 760-431-7585
Mail _. .. Telephone
D REMARKS:.
Fax../ In Person
By: Doug Moody
Esgil Corporation
D GA D Mij D EJ D PC
Enclosures:
8/15/05 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 05-2513
8/23/05
RECHECK PLAN CORRECTION LIST
JURfSDICTiON: City of Carlsbad
PROJECT ADDRESS: 2075 Las Palin.as Dr
DATE PLAN RECEIVED BY
· ESGIL CORPORATION: 8/15/05
REVIEWED BY: Doug Moody
FOREWORD (PLEASE READ):·
PLAN CHECK NO.: 05-2513
SET: II
DATE RECHECK COMPLETED:
8/23/05
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
ba~ed on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments. ·
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or dty law. ·
A. Please make all corrections on the original tracings and submit two new complete sets of
prints to:
B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C. The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior cortectio'n list,. we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
D. Please indicate here if any c~anges have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
DYes DNo
City of Carlsbad 05-2513
8/23/05
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, ~ngineering and Fire Departments. . .
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their .Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, ·Engineering and Fire Departments until review by
EsGil Corporation is complete.
These corrections are in response to items not fully addressed or as the
result of information provided, the text in bold print indicates the
unresolved issue.
1. . A complete description of the activities and processes that will occur in this
. tenant space should be provided. A listing of all hazardous materials should be·
included. The materials listing should be stated in a form that would make .
classification in Tables 3-D and 3-E possible. The building official may require a
technical report to identify and develop method.s of protection from hazardous .
materials. Section 307 .1.6. No description of th~ activities was provided.
~-Please r:eview the requirement, revise the plans and imprint on the plans the City
of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans.
Please revise the mechanical plans sheet M-2 to be consistent with the City
of Carlsbad Roof mounted Policies ahd Procedure.
4. Please provide plans and c_alculations signed by the California State licensed
engineer or architect for the structural support of the rooftop air.handler units.
Include all calculations and finding on the plans. Please include the California
license number, seal, date of license expiration and date plans are signed.
Business and Professions Code. Please indicate the equipment unit numbers
from sheet M-2 on the new sheet M-4 clearly showing the location of the
new units and showing the removed units platforms to be designed for an
equal or greater load.
The jurisdiction has contracted with Esgil Corporation located at 9320
.Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
\,.
EsGil Corporation
In <Partnersli.ip witli (]oTJemment for (}Jui[aing Safety
DATE: 7/20/QS
JURISDICTIQN: City of Carlsl>ad
PLAN CHECK NO.: os-·2513
PROJECT ADDRESS: 2075 Las Palmas Dr
PROJECT NAM!;: Cygnus -TI
SET:i
D APPLICANT ~ D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check .list
and should be corrected and resubmitted for a complete recheck.
[S1 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation m1til corrected plans are submitted for recheck.
D. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[g'.J The applicant's copy of the check list has been sent to:
McArdle and Associates / Kirk Moeller
5838 Edison Place Suite 100, .Carlsbad, CA 92008 /
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
[S1 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Kirk Moeller Telephone#: 760-431-7775
Date Qo,nt~cted:7 /2-, }os (by: F-AX) Fax #: 760-431.-7585
Mall -f elephone
D REMARKS:
Fax......--In Person ·
By: Doug Moody
Esgil Corporation
D GA D MB D EJ D PC
Enclosures:
7/8/05 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Piego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 05-2513
7/20/05
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 05-2513
· OCCUPANCY:. B
TYPE OF CONSTRUCTION: VN
. ALLOWABLE FLOOR AREA:
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDIC1ION: 7/6/05
. DATE INITIAL PLAN REVIEW
COMPLETED: 7 /20/05
FOREWORD .(PLEASE READ):
JURISDICTION: City of Carlsbad
USE: Office
ACTUAL AREA: 7191
STORIES: 1
HEIGHT:
OCCUPANT LOAD: 71
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 7/8/05
PLAN REVIEWER: Doug Moody
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanic;;al Code, National Electrical. Code and state laws
regulating energy conservation, noi~re attenuation and access for the disabled. This plan review
is based ort regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance .of a building permit.
Code sections cited are based on the 1997 UBG,
The following items listed n~ed. clarification, modification or change. All it~ms must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Unifor,m Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To· speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e:, plan sheet number, specification section, etc.
Be· ~ure to enclose the .marked up iist when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot
..,
'v City of Carls~ad 05-2513
7/20/05
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
· for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to,EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
·9320 Chesapeake Drive., Suite 208, San Diego; CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. A complete description of the activities and processes that will occur in this
tenant space should be provided. A listing of all hazardous materials should be
included. The materials listing should be stated in a form that would make
classification in Tables 3-D and 3-E possible. The building official may require a
technical report to identify and develop methods of protection from hazardous
materials. Section 307.1.6.
2. Please revise the door schedule to show door 120A to comply. Corridors shall
have interior door openings protected by ti_ght:-fitting smoke and draft control
assemblies rated 20 minutes. Doors shall be maintained self-closing or be
automatic closing by action of a smoke detector per Section 713.2_. Doors shall
be gasketed to provide a smoke and draft seal where the dobr meets the stop on
sides and top. Section 1004.3.4.3.2.1.
3. Please review the requirement, revise the plans and imprint on the plans the City
of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans.
4. Please provide plans and calculations signed by the California State licensed
engineer or architect for the structural support of the rooftop air handler units.
Include all calculations and finding on the plans. Please include the California
license number, seal, date of license expiration and date plans are signed.
· Business and Professions Cbde.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sh·eet, note or detail number,
calculation page, etc,
Please indicate here if ,;my changes have been made to the plans that are not a
result of corrections from this list. .If there ate other changes, please briefly
· describe them and where they are located in the plans.
City of Carlsbad 05-2513
7/20/05
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes IJ No Cl
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560:..1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
v City of Carlsbad 05-2,513
7./20/05
jVALUATiON AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: Doug ,Moody
PLAN CHECK NO.: 05-2513
DATE: 7/20/05
BUILDING ADDRESS: 2075 Las Palmas Dr ·
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN
13UILDING AREA Valuation Reg. VALUE
PORTION (Sq.Ft.) Multiplier Mod.
Tl 7191 CitV Valuation . . .
Air Conditioning-
Fire Sprinklers
---·
TOT.Al VALUE
Jurisdiction'Code · cb By Qrdinllnce
1994 UBC Building Permit Fee ;!' I
/
1994 UBC Plan Check Fee -:srl
Type of Review: 0 Complete Review D Structural Only
_ D Repetitive Fee
~-Repe"ts · ~ '
Comments:
D Other
D Hourly 1 · · I Hour *
· EsgU Plan Review Fee
($)
215,730
. 215,730
$903.841
$587.SOI
$506.151
Sheet 1 of 1
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER ~CB_~_-S_--~---._$_I~----____ DATE __,,'l,__1/~· }~_-C-__ _ , f
'
AgDRESS ....... _1,1)_7._. ~-....... llf-S;;....;_..,..__-_/Ji-"!"'~_t_M,ts_· ________ _
"RESIDENTIAL
RESIDENTIAL ADDfflON MINOR
( < $10,000.00) .
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE· FAIRE
COMPLETE OFFICE BUILDING
OTHER ---------------------------
PLANNER _______ ~-----~-· __ _ DATE 7/e/n ----=-+-, ~t.;-_.;;... __
ENCINEER·4 ~~
~---~--
TITLE 24 REPORT
Title 24 Re.port for:
CYGNUS Tl
2075 LAS PALMAS DR
CARLSBAD,CA
Project Designer:
Aelott Air Conditioning
812 West Washington Ave.
Escondido.; Ca 92025
760-7 46-1.333 ·
Report Prepared ·By:
Jeanne Fricot, CEA
Haynal & Co.
508 W Mission Avenue, Suite 201
Escondido, CA 92025
(760) 7 43-5408
Job Number:
Date:
6/27/2005'
The EnergyPro computer prqgram has been used to perform the calculations ·summarized _in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400 ..
EnergyPro. 3.1 By EnergySoft Job Number: User Number: 2875