Loading...
HomeMy WebLinkAbout2086 CALETA CT; ; CB991642; Permit07/08/1999 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad Residential Permit Permit No:CB991642 Building Inspection Request Line (760) 438-31 01 2086 CALETA CT CBAD RESDNTL SubType: RAD Status: ISSUED 2151101200 Lot #: 0 Applied: 04/29/1999 Reference #: Plan Approved: 07/08/1999 0 Structure Type: Issued: 07/08/1999 0 RAD-ADD NEW 1095 SF INTERIOR REMODEL 2790 SF UPGRADE ELEC SVC TO Plan Check#: $1 79,850.00 Construction Type: VN Entered By: JM Bathrooms: 0 Inspect A Orig $p 07/@/99 0001 01 02 C-FKWT I227 9 0.5 Applicant: Owner: COTHRAN DAVID 910 NARD0 ROAD ENClNlTAS CA 92024 760-753-1 566 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee $188.00 BTD #3 Fee $35.00 Renewal Fee $0.00 --"+'~TEHANICAL TOTAL $85.00 Add'l Renewal Fee $0.00 Housing Impact Fee $0.00 Other Building Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Master Drainage Fee: $0.00 Meter Size Sewer Fee: $0.00 Add'l Pot. Water Con. Fee $0.00 TOTAL PERMIT FEES $1,812.76 FlNAl APPRn\/L\L @ Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "feeslexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified feedexactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any feeslexactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 (760) 438-1 161 FOR OFFICE USE 0 issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the bass for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five h Name State License # 6 5'3 2% Designer Name Address city Statekip' ~ Telephone Telephone'# Sf0 EdMDO @ a+ccn c L city Statelzip City Business License # G\LL PLasQEGr7 eb4-c u qw'LY(266) Ql4Q b44 I UC LQ? cauLz!3 b Address 1()LLMA&L CU-CG Ca6 License Class I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is of the work for which this permit is issued. issued. My worker's compensation insurance carrier and policy number are: Insurance Company q-/L.E w Expiration Date b -99 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUND 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($lOO,OOqllb addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. R DECLARATION -.- I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. 4. number I contractors license number): 5. of work): I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address 1 phone number I type Business and Professions Code for this reason: PROPERTY OWNER SIGNATURE DATE UlLDllYO PER Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). 0 YES El ENDING A LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citv of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit iss work authorized by such or abandoned at any time Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or menced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE Y DATE q-27-9 9 WHITE: File YELLOW: Applicant PINK: Finance UNSCHEDULED BUILDING INSPECTION DATE pIZ-oi, INSPECTO dL PERMIT ## * JOB ADDRESS ’ PLAN CHECK # 20S6 [h/ e f& DESCRIPTION CODE fi DESCRIPTION 3 ACT COMMENTS City of Carlsbad Bldg Inspection Request For: 9/22/2000 Permit# CB991642 Inspector Assignment: DA Title: RAD-ADD NEW 1095 SF Description: INTERIOR REMODEL 2790 SF UPGRADE ELEC SVC TO 2OOAMP Type: RESDNTL SubType: RAD Job Address: 2086 CALETA CT Suite: Lot 0 Location: APPLICANT COTHRAN DAVID Owner: BROWN DAVID&JOAN TRUST 10-07-86 Remarks: PM PLEASE - AFTER NOON PLEASE Phone: 760431 1 181 Total Time: Requested By: DAVID CD Description Act Comments Entered By: CHRISTINE 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs Date 9/14/2000 7/24/2000 7/24/2000 6/6/2000 6/6/2000 5/2/2000 5/1/2000 4/2a/2000 4/20/2000 4/2012000 4/14/2000 4/6/2000 4/5/2000 4/3/2000 3/31 12000 412ai2000 InsDection History Description Act lnsp Comments 21 UndergroundlUnder Floor AP PD GAS FROM METER TO BBQ 17 Interior LathIDrywall AP DA 27 Shower PantRoman Tubs AP DA 16 Insulation AP DA UNDERFLOORS 27 Shower PanlRoman Tubs CO DA SEE ATTACHED NOTICE 17 Interior LathIDrywall AP PD 17 Interior LatMDrywall CO DA NAILING 17 Interior Lath/Drywall CO DA 18 Exterior LathlDrywall AP DA 16 Insulation AP DA WALLS&CLGONLY 31 UndergroundlConduit-Wiring AP DA 16 Insulation NR DA 14 FramelSteellBoltingMIding AP DA 14 FramelSteellBoltingNIding NR DA 14 FramelSteellBoltingMelding CO DA SEE BACK OF CARD 14 Frame/SteellBoltingMlelding NR DA 27 F6 . NOTICE -. CITY OF CARLSBAD FOR 1NWCT)ON CALL (760) 602-2725. RE-INSPECTION FEE DUE? YES 1 /' ER )?ORMATION, CONTACT FoRFYt $ PHONE I I !I ' BUILDING INSPECTOR CODE ENFORCEMENT OFFICER @ City of Carlsbad Bldg Inspection Request For: 6/6/2000 Permit# CB991642 Title: RAD-ADD NEW 1095 SF Inspector Assignment: DA Description: INTERIOR REMODEL 2790 SF UPGRADE ELEC SVC TO POOAMP Type: RESDNTL SubType: RAD Job Address: 2086 CALETA CT Suite: Lot 0 Location: APPLICANT COTHRAN DAVID Owner: BROWN DAVID&JOAN TRUST 10-07-86 Phone: Inspector: * Remarks: Total Time: Requested By: DAVID Entered By: CHRISTINE CD Description Act Comments 16 Insulation AP Urn@. Gk.5. 27 Shower PanlRoman Tubs & 56 drnE Associated PCRs Date 5/2/2000 5/1/2000 4/28/2000 4/28/2000 4/20/2000 4/20/2000 4/14/2000 4/6/2000 4/5/2000 4/3/2000 3/31 12000 311 312000 2/18/2000 1/18/2000 1/10/2000 1 /I 0/2000 1 1/4/1999 InsDection History Description 17 Interior LathlDrywall 17 Interior LathlDrywall 17 Interior Lath/Drywall 18 Exterior LathlDrywall 16 Insulation 31 UndergroundlConduit-Wiring 16 Insulation 14 Frame/Steel/BoltingNelding 14 Frame/Steel/BoltingNelding 14 FramelSteel/BoltinghVelding 14 Frame/Steel/BoltingNelding 11 FtglFoundationlPiers 14 FramelSteellBoltingNelding 15 RoofIReroof 14 FramelSteellBoltingNelding 15 Roof/Reroof 11 FtglFoundationlPiers Act lnsp Comments AP PD CO DA NAILING CO DA AP DA AP DA WALLS&CLGONLY AP DA NR DA AP DA NR DA CO DA SEEBACKOFCARD NR DA 27F6 AP DA GAR FOOTING WALL FOR PANTRY ONLY NR DA AP DA WC DA NR DA AP DA CHK BEFORE POUR MON CITY OF CARLSBAD NOTICE (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE FOR INSPECTION CALL (760) 602-2725. FOR FURTHER INFORMATION, CONTACT RE-INSPECTION FEE DUE? c YES PHONE @ ~LDING INSPECTOR CODE ENFORCEMENT OFFICER EsGil - Corporation 1n partnersfiip witfi Sjovernment for SuiGfitrg Safety DATE: July 1, 1999 JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1642 SET: I1 PROJECT ADDRESS: 2086 Caleta Court PROJECT NAME: SFD Addition for Brown 0 w 0 0 0 0 w 0 w 0 PLAN REVIEWER 0 FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Mail Telephone Fax In Person REMARKS: 1 pa nsion/e poxy anchors need e the special inspection e recommended R-value er show a note on the double glazed, Enclosures: 6/2 1 /99 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: 20 CtkbYA cr. ) &RLSt3&9, CA. WO@l PLAN CHECK NUMBER: 99 - b'kz OWNER'S NAME: IsQeOWh) I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) e construction project located at the site listed above. UBC Section 106.3.5. I) m: I, as the engineedarchitect of record, certify that I will be responsible for,employing the special inspect.r;r(s) a3 required by VBC Ssctisn 174G=31.1 for the consiriction project locakd a& the site listed above. UBC Section 106.3.5. Engineer'dArchtect's Seal & Signature Here Signed 1. List of work requiring special inspection: 0 0 ci 2. Soils Compliance Prior to Foundation Inspection Structural Concrete Over 2500 PSI Prestressed Concrete Expansion/Epoxy Anchors Structural Masonry 0 Sprayed-On Fireproofing Designer Specified 0 Other Name(s) of individual@) or firm@) responsible for the special inspections listed above: c] Field Welding 0 High Strength Bolting C. 3. Duties of the special inspectors for the work listed above: B. C. Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. SIP 4997 EsGil Corporation In Partnership with Sjovernment for BuiliCing Safety DATE: May 11, 1999 J U RI SDI CTION: Carlsbad PLAN CHECK NO.: 99-1642 PROJECT ADDRESS: 2086 Caleta Court PROJECT NAME: SFD Addition for Brown 0 cl 0 w 0 w w 0 0 Cl FILE SET: I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: David Cothran 910 Nardo Rd., Encinitas, CA 92024 Esgil Corporation staff did not advise the applicant(except by mail) that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: REMARKS: Mail Telephone Fax In Person By: Bert Doming0 Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 5/3/99 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 Fax (619) 560-1576 Carlsbad 99- 1642 May 11, 1999 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 99-1642 J URl SDICTl ON: Carlsbad PROJECT ADDRESS: 2086 Caleta Court FLOOR AREA: 1095 SQ. FT. STORIES: ONE HEIGHT: REMARKS: - DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 5/3/99 DATE INITIAL PLAN REVIEW COMPLETED: May 11, 1999 DATE PLANS RECEIVED BY PLAN REVIEWER: Bert Doming0 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994 UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction item has been addressed, Le., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 1, GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forw.dot Carlsbad 99-1642 May 11, 1999 0 PLANS I. Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). 2. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS EXPANSION/EPOXY ANCHORS OTHER DES I G N ER-SPEC1 FI ED 3. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. 0 GENERAL RESIDENTIAL REQUIREMENTS 4. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1203.3. See Laundry and the new bathroom for the den. 0 ROOFING 5. Specify on the plans the following information for the roof materials, per Section 106.3.3: a) Manufacturer's name. b) Product namehumber. c) ICBO approval number, or equal. 6. Provide skylight details to show compliance with Sections 2409 and 2603, or specify on the plans the following information for the skylight(s), per Section 106.3.3: a) Manufacturer's name. b) Model namehumber. c) ICBO approval number, or equal. Carlsbad 99- 1642 May 11, 1999 7. 8. 9. IO. 11. 12. 13. 14. 15. Show attic ventilation. Minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. Note on the plans: corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension." Section 1505.3. "Attic ventilation openings shall be covered with FOUNDATION REQUIREMENTS Show minimum underfloor access of 18" x 24". Section 2317.3. Show minimum underfloor ventilation equal to I sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practical and shall provide cross ventilation on at least two approximately opposite sides. Section 231 7.7. 0 FRAMING Specify truss identification numbers on the plans. Per UBC Section 2343.6, provide the following note on the plans if trusses are used: "Each truss shall be legibly branded, marked or otherwise have permanently affixed thereto the following information located within 2 feet of the center of the span on the face of the bottom chord: a) b) The design load. c) Identity of the company manufacturing the truss. The spacing of the trusses." Provide calculations for main vertical and horizontal framing members and footings. Section 106.3.3. Provide calculations for lateral loads, shear panels, shear transfer and related. Section 106.3.3. 0 MECHANICAL (UNIFORM MECHANICAL CODE) Provide dryer vent to outside. The maximum length is 14 feet with two 90-degree elbows. UMC. Section 504.3.2. Carlsbad 99- 1642 May 11,1999 16. 17. 18. 19. 20. 21. 22. 23. 24. 0 PLUMBING (UNIFORM PLUMBING CODE) Show T and P valve on water heater and show route of discharge line to exterior. UPC, Section 608.5. Show that water heater is adequately braced to resist seismic forces. Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank). UPC, Section 510.0 0 ENERGY CONSERVATION Provide plans, calculations and worksheets to show compliance with current en erg y stand a rd s . The regulations require a properly completed and properly signed Form CF-IR to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. Specify on the buildinq plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms. Provide a note on the plans stating "All new glazing (fenestrations) will be installed with a certifying label attached, showing the U-value." Show the make, model, type and efficiency of the space heating (or cooling) system. Carlsbad 99-1642 May 11, 1999 25. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaMndustria1 projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1 161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculationslreports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (61 9) 560-1 468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, Le., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Doming0 at Esgil Corporation. Thank you. Carlsbad 99- 1642 May 11, 1999 Air Conditioning Fire Sprinklers TOTAL VALUE J U RI SDl CTl ON: Carlsbad ** $ 179,850.00 VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 99-1642 DATE: May 11,1999 PREPARED BY: Bert Doming0 BUILDING ADDRESS: 2086 Caleta Court BUILDING OCCUPANCY: R 3 TYPE OF CONSTRUCTION: V N BUILDING PORTION MULTIPLIER H 1994 UBC Building Permit Fee H 1994 UBC Pian Check Fee Type of Review: H Complete Review 0 Structural Only 0 Hourly 0 Repetitive Fee Applicable 0 Bldg. Permit Fee by ordinance: $ 901.08 0 Plan Check Fee by ordinance: $ 585.70 0 Other: Esgil Plan Review Fee: $ 468.56 Comments: ** Valuation was taken from the city’s estimate dated 4/29/99 Sheet I of 1 macvalue.doc 51 96 BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB ‘?? /6 f2 - C%l& L+- PROJECT DESCRIPTION: Qm ASSESSOR’S PARCEL NUMBER: (5rl s- /lo f 9 EST. VALUE: / 77; Bs6 ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. Right-of-way permit is required prior to construction of the following improvements: Please see the attached report of deficiencies marked with 0. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: By: Date: By: Date: FOR OFFICIAL USE ONLY 11 II t.n ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: II By: 1 Date: s/a 7 /* I I /i \\ -4 ~~&CI)MENTS ENGINEERING DEPT. CONTACT PERSON v Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Name: JOANNE JUCHNIEWICZ City of Carlsbad Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Phone: (619)438-1161, ext. 4510 CFD INFORMATION Parcel Map No: Lots: Right-of-way Permit Application Right-of-way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet Recordation: Carlsbad Tract: A-4 @ “wOR~~S~P~~~B~.~~lsbad, CA 92009-3576 - (760) 438-1 161 - FAX (760) -1-69 - BUILDING PLANCHECK CHECKLIST SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines B. Existing & Proposed Structures E. Easements C. Existin Street Im rovements F. Right-of-way Width & Adjacent Streets bd1y -6Llc G. Driveway widths 2. Showonsite plan: sh bo& -& 4 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: “Finish grade will provide a minimum positive drainage of 2% to swale 5’ away from building.” B. Existing & Proposed Slopes and Topography A. Drainage Patterns &----+ ~*+--yy 3. Include on title sheet: A. Site address B. Assessor’s Parcel Number C. Legal Description For commercial/industriaI buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. 4b. All conditions are in compliance. Date: BUILDING PLANCHECK CHECKLIST DEDICATION REQUIREMENTS ZE ZND‘ 3RD‘ 0 5. Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ , pursuant to Carlsbad Municipal Code Section 18.40.030. FCI Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 X” x 11” plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: / IMPROVEMENT REQUIREMENTS CI 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of buildina construction whenever the value of the 1 construction exceeds $ Section 18.40.040. , pursuant to Carlsbad Municipal Code Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: D 0 0 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: current grant deed on the property and processing fee of $ so H:\WORW)C€S\CHKLSnBuildhg Plancheck CkkI BPWOl Form JJ.doc 3 BUILDING PLANCHECK CHECKLIST 0 CI 0 0 0 D 0 CI 0 0 0 c3 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaaed or defective imwovements found adiacent to buildina site must be reDaired to the satisfaction of the Citv InsDector prior to OccuDancv. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. The Gradina Permit must be issued and rouclh qradinq awroval obtained prior to issuance of a Buildina Permit. NOTE: Grading Inspector sign off by: Date: 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) 7d.No Grading Permit required. 7e.lf grading is not required, write “No Grading” on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or private work adjacent to the public Right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-way permit required for: BUILDING PLANCHECK CHECKLIST 4 H \WORDUX)CS\CHKLST\BUldlnp Plancheck Cklst BPW1 Form JJ doc Rev 12/28/88 . D 9. A SEWER PERMIT is required concurrent with the building permit issuance. The 3d‘ fee is noted in the fees section on the following page. IO. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for assistance. F a Industrial Waste permit accepted by: Date: 11. NPDES PERMIT k’ Complies with the City’s requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. CI uired fees are attached No fees required D o D 13. Additional Comments: H:\WORD\OOCSCM(LST\BuildinO Planchedr CkI BPDool Form JJ doc 5 Rev. 12125B6 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 99 \ 6 4.2 Planner Paul Godwin Phone (61 9) 438-1 161, extension Type of Project & Use: S F 9. Ad A ;+ i on Net Project Density: Zoning: Re I General Plan: RLm Facilities Management Zone: 6 CFD linlnirtl # Date of participation: Remaining net dev acres: Address 20 86 c a 1 e4 c-b. 4329 DU/AC APN: 2 IS .IlO. \a Circle One - (For non-residential development: Type of land used created by this permit: 1 Item Incomplete - Needs your action - Leaend: Item Complete Environmental Review Required: YES - NO x TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: YES-NO - )( TYPE Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES- NOX CA Coastal Commission Authority? If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 - NO YES - Determine status (Coastal Permit Required or Exempt): If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Coastal Permit Determination Form already completed? YES- NO- Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: YES (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) - Data Entry Completed? YES NO (AIPIDs, Activiv Maintenance, enter CBfY, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!) Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1. Setbacks: Front: Required a 0' Interior Side: Required 5'- 5" Street Side: Rear: Required - Required \ai- (0 " 2* 3. 4. 5. Front: Interior Side: Required Shown 35' Shown 5'-1" Shown - Shown rf Shown Shown Street Side: Required Rear: Required Structure separation: Required Lot Coverage: Required L, 40 Height: Required - Pi' Parking: Spaces Required 2 car qar 4) Guest Spaces Required Shown Shown Shown 37 "/b Shown 2 Car Gee Shown J Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTERQ~ &$M, DATE5131qq - City of Carlsbad CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project Name: Building Permit Plan Check Number: Project Address: A.P.N. : Project Applicant (Owner(s) Name(s)) Project Description: Building Type: Residential L":d i3coLm a\c ssp>rq Ad &+tan 5 Fb Number of New Dwelling Units w4 Square Feet of Living Area in New Dwelling ,Q/A Second Dwelling Unit: Res. Additions: w4 I0015 d Square Feet of Living Area in SDU Net Square Feet New Area Comerc./ Ind.: City Certification of IWfi Square Feet Floor Area I/@/? ? Date: -- Applicant's information: r- I A I \/3 b. I D SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD San Marcos Unified School District 21 5 Mata Way San Marcos, CA 92069 (736-2200) San Dieguito Union High School District 710 Encinitas Blvd. Encinitas, CA 92024 (753-6491) Encinitas Union School District 101 South Ranch Santa Fe Rd Encinitas, CA 92024 (944-4300) Certification of Applicant /Owners. The person executing this declaration rownet') certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square the initial determination of units or square footage is found to be incorrect, and the above described project(s), or that the person executing this declaration is Signature: Date: I*- 99 2075 Las Palmas Dr. Carlsbad, CA 92009-1576 (760) 438-1 161 - FAX (760) 438-0894 @ Revised 3-18-99 L & SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. ................................................................................................... SCHOOL DISTRICT: The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER services C?rlSh?d U~~~ol District .-- _. - ?‘J;.xJe ’ L !.hi-nia 92008 7, 74/99 9.d -Ya%aka& - Revised 3-18-99 1 1 /02/1999 City of Carlsbad Plan Check Revision Permit No:PCR99234 Building Inspection Request Line (760) 438-31 01 Job Address: Permit Type: PCR Status: ISSUED Parcel No: 2151101200 Lot #: 0 Applied: 09/17/1999 Valuation: $0.00 Construction Type: VN Entered By: RMA Reference #: CB991642 Plan Approved: 11/01/1999 Issued: 11/02/1999 Project Title: BROWN RES-REV-BEAM,FOOTINGS, Inspect Area: 2086 CALETA CT CBAD FINAL APPROVAL Inspector: Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exadions.' You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to Smely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified feeslexactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any feedexactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othewise expired. CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged re than five hundred dollars [$500]). Name Address City Statelzip f elephone # State License # License Class 1 City Business License # & ';I nd rh 9W - cp 64- ! Telephone Address . City StateIZip ' ' State License 1 8. WORKERS' COMPENSAnON Workers' Compensation Declaration: I h penalty of perjury one oft 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company GracrZ ~w Policy NO. 107 W 5 LI ?? Expiration Date 6- (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS1$1001 OR LESS1 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coveraga b unlawful, and shall subject an employer to criminal penaltias and civil fines up to one hundred thousand dollars 1$100.000). in addition to the cost of compensation. damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: a I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement IS sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property. am exclusively contracting wtth licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects wlth contractor(s) licensed pursuant to the Contractor's License Law). 1. 2. 3. 7. OWNRl-8UIt.DER DECLARATION I am exempt under Section I personally plan to provide the major labor and matenals for construction of the proposed property improvement. 0 YES UNO I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): Business and Professions Code for this reason: ~~~ 4. number I contractors license number): 5. of work): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type PROPERTY OWNER SIGNATURE DATE COMPLETETHIS SECTION FOR /VO/U-R€SD~ 3UILDUUO PERMITSBN Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES [7 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). CONSTRUCTION LENDJNG AGENC LENDER'S NAME LENDERS ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Ci) of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit work authorized by such pe or abandoned at any time after the APPLICANT'S SIGNATURE limitation and become null and void if the building or ilding or work authorized by such permit is suspended WHITE: File YELLOW: Applicant PINK: Finance L4 . .. - EsGil Cornoration I In Tartnersfiip with Sjovernment for Buihfing Safety DATE: September 29, 1999 J U Rl SDl CTI ON: Carlsbad R PLAN REVIEWER FILE PLAN CHECK NO.: PCR99234(CB991642.rev) SET: I PROJECT ADDRESS: 2086 Caleta Court PROJECT NAME: SFD Revision for Brown 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: David Cothran 910 Nardo Rd., Encinitas, CA 92024 Esgil Corporation staff did not advise the applicant(except by mail) that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person 0 REMARKS: By: Bert Doming0 Enclosures: Esgil Corporation 0 GA 0 MB ,a EJ 0 PC 9/20/99 trnsrntl .dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad PCR99234(CB99 1642.rev) September 29, 1999 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO. : PCR99234( CB99 1642.rev) PROJECT ADDRESS: 2086 Caleta Court FLOOR AREA: STORI ES: JURISDICTION : Carlsbad HEIGHT: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 9/20/99 DATE INITIAL PLAN REVIEW COMPLETED: September 29, 1999 DATE PLANS RECEIVED BY PLAN REVIEWER: Bert Doming0 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a CODY) where each correction item has been addressed, Le., plan sheet number, specification section, etc. Be sure to enclose the marked UP list when vou submit the revised plans. Carlsbad PCR99234(CB99 1642.rev) September 29, 1999 I. 2. 3. 4. 5. 6. 7. 8. 9. IO. 11. 12. 13. 14. PLANS Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). MISCELLANEOUS Please have a schedule of revision on the sheets being affected and bubble the area with the corresponding revision #. Please show the recommended conventional truss connection detail on the plans. Please show detail of the relationship of RBI and RB25. RBI recommendation is different than what is shown on the plan. Please clarify. Where is the RB2 calculation? Page 5 of the calculations shows line A with shear walls but not shown on the plans. Please clarify. Please show on the plan the recommended stem wall detail shown on page 4 of the calculations. Any foundation for the RB23 supports? Please clarify the foundations shown along lines 6 & 5 between E & F. Please identify the pad footings on page 4 of the calculations and cross reference to the foundation plan. Please show the size of the pad footings on the foundation plans. Please submit calculations for the RBI7 to carry the new RBI (per calculations). The window of the new bedroom(adjacent to the new master closet) may not meet the egress requirement. Please clarify. Carlsbad PCR99234(CB99 1642.rev) September 29, 1999 15. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industriaI projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculationsheports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1 161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculationsheports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 NO a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 8581560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Doming0 at Esgil Corporation. Thank you. Carlsbad PCR99234(CB99 1642,rev) September 29, 1999 VALUATION AND PLAN CHECK FEE BUILDING PORTION VALUATION VALUE L ($) M U LTI PLI ER JURISDICTION : Carlsbad PCR99234(CB99 1642.rev) PREPARED BY: Bert Doming0 PLAN CHECK NO.: DATE: September 29, 1999 BUILDING ADDRESS: 2086 Caleta Court BUILDING OCCUPANCY: R 3 TYPE OF CONSTRUCTION: V N Air Conditioning Fire Sprinklers TOTAL VALUE 0 199 UBC Building Permit Fee 0 Bldg. Permit Fee by ordinance: $ 0 199 UBC Plan Check Fee 0 Plan Check Fee by ordinance: $ 326.81 Type of Review: .Complete Review 0 Structural Only Hourly 0 Repetitive Fee Applicable 0 Other: Esgil Plan Review Fee: ** $ 231.45 Comments: ** Fee was based on 3 hours plan check time @ $87.15/hr. Sheet1 of I macvalue.doc 5196 Carlsbad PCR99234(CB99 1642.rev) September 29, 1999 VALUATION AND PLAN CHECK FEE(REVISED 10/6/99) J URl SDl CTl ON : Carlsbad PCR99234(CB99 1642.rev) PREPARED BY: Bert Doming0 PLAN CHECK NO.: DATE: September 29, 1999 BUILDING ADDRESS: 2086 Caleta Court BUILDING OCCUPANCY: R 3 TYPE OF CONSTRUCTION: V N I--- I I I Air Conditioning Fire Sprinklers I TOTALVALUE I ,I I 0 199 UBC Building Permit Fee 0 Bldg. Permit Fee by ordinance: $ 0 199 UBC Plan Check Fee 0 Plan Check Fee by ordinance: $ 326.81 Type of Review: .Complete Review 0 Structural Only H Hourly 0 Repetitive Fee Applicable 0 Other: Esgil Plan Review Fee:** $ 321261.45 Comments: ** Fee was based on 3 hours plan check time @ $87.15/hr. Sheet 1 of 1 macvalue.doc 5196 CLIENT w @Law + LA COSTA ENGI NEW NG 106 ’ b=tbt* /- CALCULATED BY )4&M DATE CHECKED By 2382 CAMINO VlDA ROBLE STE L CARLSBAD CALIFORNIA 92009 TEL 760-931-0290 FAX 431-1468 DATE /&do jo-’sw963 EMAll lcenqr@connectnel corn CIVIL STRUCTURAL MECHANICAL* PETROLEUM SCALE SHEET NO/OF 6 CALCULATED BY DATE CHECKED By DATE SCALE 2382 CAMINO VlDA ROBLE STE L CARLSBAD. CALIFORNIA 92009 TEL 760-931-0290 FAX 431.1468 EMAIL: IcenqrOconnectnel.com CIVIL STRUCTURAL MECHANICAL- PETROLEUM SHEET NOZOF 2382 CAMINO VlDA ROBLE STE L CARLSBAD. CALlfORNlA 92009 TEL 760-931-0290 FAX 431-1468 EMAIL- Icengt8connectnet corn CIVIL - STRUCTURAL MECHANICAL* PETROLEUM CLIENT JOB CALCULATED BY DATE CHECKED By DATE SCALE SHEETNO 3 OF __ ..._ . .. . .. . . .. .. . . 2382 CAMINO VlOA ROBLE STE L CARLSBAO. CALIFORNIA 92009 TEL 760-931-0290 FAX 431-1468 EMAIL: Icengr@connectnet.com CIVIL STRUCTURAL MECHANICAL* PETROLEUM CLIENT JOB CALCULATED BY DATE CHECKED BY DATE SCALE SHEET NO-OF 4- 2382 CAMINO VlDA ROBLE STE L CARLSEAD. CALIFORNIA 92009 TEC 760-931-0290 FAX 431-1468 EMAIL: Icengr@connectnet.com CIVIL STRUCTURAL MECHANICAL- PETROLEUM CLIENT JOB CALCULATED BY DATE CHECKED By DATE SCALE SHEET NOLOF 2.OE PARALLAM@ PSL ALLOWABLE DESIGN STRESSES (100% LOAD DURATION) ; SHGR (Ibr.) I MOMENTOFlNERTlA(in4) Shear modulus of elasticity G = 125,000 psi ' Modulus of elasticity E - 2.0 x 106 psi Flexural stress Compression perpendicular to grain parallel to wide face of strands Horizontal shear perpendicular F, = 2900 psi(') Fd = 650 psi(z)(3) Compression parallel to grain F,ll = 2900 psi to wide face of strands F, = 290 psi 4,805 4,935 5,845 6.170 7,275 8.315 9.350 175 190 320 375 615 915 1,305 (1) For 12-inch depth. For others, multiply by [Y]""' (2) Fdshall not be increased for duration of load. (3) 750 psi for all Eastern Species Parallam@ PSL and 1%' thick Western Species Parallam@ MOMENT(ft Ibs;) SHEAR [Ibr.) PSL 18,625 19,585 26,955 29,855 40,740 52,430 65,495 9,390 9,645 11,420 12,055 14,210 16,240 18,270 ALLOWABLE DESIGN PROPERTIES (100% LOAD DURATION) 1%'' 2.OE Parallam@ PSL 21?k1' 2.OE PARALLAM@ PSL WEIGM (IbsJIin. ft) - i '1 ' 31h" 2.OE PARALLAM@ PSL 15.2 15.6 18.5 19.5 23.0 26.3 29.5 7" 2.OE PARALLAM@ PSL I. I DEPTH I DESIGN PROPERTY DESIGN PROPERTY MOMEF . . ,^ (ft. lbs.) I 9,535 110.0251 13,800~15,280~20,855~26,840~33,530~ ,,- WEIGKF[Ibr./lin.~fi.) I 7.8 I 8.0 I 9.5 1 10.0 I 11.8 I 13.4 I 15.1 ''% 5%'' 2.OE PARALLAM@ PSL [MOMENT OF INERTIA (in4) I 345 I 375 I 625 1 735 I 1,200 I 1,790 12,550 I GENERAL ASSUMPTIONS FOR NON-TREATED PARALLAM@ PSL Lateral support is required at all bearing points and along compression edge at intervals of 24" on-center or closer. Parallam@ PSL beams are made without camber; therefore, in addition to com- plying with the deflection limitc of the applicable building code, other consider- ations, such as long term deflection under sustained loads (including creep), ponding (positive drainage is essential) and aesthetics, must be evaluated. Roof members shall either be sloped for drainage or designed to account fof load and deflection as specified in the applicable building code. Reductions applied in accordance with: 1994 UBC 1606, 1996 NBC 1606 and 1994 SBC 1604 for floor live load: 1994 UBC 1606, 1996 NBC 1607 and 1794 SBC 1604 for roof live load in non-snow (125%) conditions. 5V4" members may be three pieces 1%". one piece 1%" with one piece 3%". or a single 5'/4" width beam. 7" members may be hvo pieces 1%" around one piece 3%" , two pieces 3%". or a single 7" width beam. lee pages 16 and 17 for multiple member beam connections. 3%" members may be two pieces of 1%" or a single 3%" width beam. 444 eosr44 CLIENT bfi ENGINEERI NG JOB bmN@ ps-s\bwCF 2382 CAMINO VlDA ROBLE STE 1 CALCULATED BY tafl DATE 8-11-99 MECHANICAL- PETROLEUM SCALE SHEET NOLOF 4 CARLSBAD. CALIFORNIA 92009 TEL 760-931-0290 FAX 431-1468 EMAIL lcengr@connectnet corn CIVIL STRUCTURAL CHECKED BY DATE 2382 CAMINO VlDA ROBLE STE L CARLSBAD. CALIFORNIA 92009 TEL 760-931-0290 FAX 431-1468 EMAIL: IcenQr@connectnet.com MECHANICAL- PETROLEUM CIVIL STRUCTURAL CLIENT JOB CALCULATED BY DATE CHECKED BY DATE SCALE SHEET NO~OF 4/34 COSTA ENGINEERING 2382 CAMINO VlDA ROBLE STE L CARLSBAD, CALIFORNIA 92009 TEL 760-931-0290 FAX 431-1468 EMAlL IcenQr@connectnet corn CIVIL STRUCTURAL MECHANICAL- PETROLEUM CLIENT 106 CALCULATED BY DATE CHECKED BY DATE SCALE SHEET NOAOF Q 1 :: ..