HomeMy WebLinkAbout2091 LAS PALMAS DR; D; CB080654; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 05-21-2008 Commercial/Industrial Permit . Permit No: CB080654 · Building Inspection Request Line (760) 602l!2725 Job Address: 2091 LAS PALMAS DR CBAD St: D Permit Type: Tl Sub Type: INDUST 0 ' Parcel No: 2130611600 Lot#: Status: Valuation: $38,500.Q0 Construction· Type: 58 Applied: Occupancy Group: Reference #: Entered By: Project Title: BEERY GROUP-1100 SF Tl OF Plan Approved: OF EXISTING 1600 SF OFFICE/WAREHOL,ISE TO SAME Issued: Applicant JOHN BEERY STE G-3 5751 PALMER WAY 92010 760438 2963 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park.Fee LFM Fee Bridge Fee BTD#2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee . Reel. Water Con. Fee $319.59 $·a.on $207.73 $50.00 $0.00 $8.09 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Inspect Area: Plan Check#: Owner: .. ,· SIERRA LAND GROUP INC :,. 801 N BRAND BLVD #1010 GLENDALE CA 91203 Meter Size Add'I Reel. Water Con; Fee Meter Fee SDCWAFee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (43055~f1) PLUMBING TOTAL ... ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMPFee TOTAL PERMIT FEES ISSUED 04/11/2008 LSM 05/21/2008 05/21/2008 Total Fees: $653.41 Total Payments To Date: $653.41 Balance Due: I-v.JJl'DING~L -I~ ~"-€4> ~INSTO . ' · _ATTACH-D ln~pector: ~ FINAL APPROVAL Date: Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $35.00 $33.00 $0.00 $0.00 $0.00 $0.00 ?? $653.41 $0.00 NOTICE: Please take NOTICE that approval of your project Includes the "Imposition" of fees, dedications, reservations, .or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these feesb:lxactions. If you protest them, you must follow tlie protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32:030. Failure to tirnely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. , City of Carlsbad -- Plan Check No. C!8 O'S()b St/, ....... ~ ... -~~ Ii~' 1635 Faraday Ave., Carlsbad, CA 92008 • ',(JJ,r:. Est. Value 760-602-2717 / 2718 / 2719 / 2121 1 , .. Fax: 760-602-8558 ' .-,;:, ... .,,:. .. ~,. Plan Ck. Deposit 'fil...m~wu, I Building Permit· Application ~ 4-1, ~ I o-'i Date -• JOB ADDRESS 2091 Las Palmas Prive SUITE#/SPACE#/UNIT# D IAPN 213 -061 -16 -00 CT/PROJECT# 'LOT# I PHASE# r OF UNITS r BEDROOMS # BATHROOMS I TENANT BUSINESS NAME I CONSTR. lYPE l occ. GROUP 8 1 H.C. Beery Group Inc. VB B-M DESCRIPTION OF WORK: IJ>.oo A-ppro)( -r-c t)F ,~oo, g;sF 0 PPI ce /(.,L)he.e r+9-U-6e Interior space planning of esixting building and addition of H.V.A.C. Unit for unconditioned space. (No site,exterior or structural addifions) EXISTING USE I PROPOSED USE r·0N~A~C) PHl()C: /C:J:\ I DECKS (SF} FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS Office/ R& D Same N.A. N.A. YESO#. NOIZ) YESIZ) NOD YESO NO[Z) - CONTACT NAME John Beery APPLICANT NAME J h B · o n eery ADDREss 5751 Palmer Way STEG-3 ADDRESS Same .CITY Carlsbad STATE CA ZIP 9201,0 CITY. STATE ZIP PHONE 760-438-2963 I FAX 760-438-2965 ·PHONE !FAX EMAIL • . . John@lovemyarQhitect.com EMAi!- .. PROPERTYOWNER-NAME Sierra Land Group Inc. CONTRACTOR BUS. NAME Monaghan Construction Co. ADDREss 801 North Brand Blvd. STE 1010 ADDRESS P.O. Box 9000-280 CITY Glendale sTATE Ca ZIP 91203 CITY Carlsbad STATE Ca ZIP 92018-9000 PHONE 818-247-3681 'FAX 818-247-4315 PHONE 760-438-2008 FAX 760-438-2919 EMAIL EMAIL '-/1 NIA NA I ARCH/DESIGNER NAME & ADDRESS Beery Group Inc. jsTATEuc.# STATELK ris 1018J111/~ 1 C-15426 . 475137 ?/l ~ Sec. 7031.5 Business and Professions Code: Any City or County which re~uires a permit to construct alie~ improve, demolish or r 1ce~sed ursuant to the pr9visions of-the C9ntrac,tor's License ~aw {Chap er .9, commending with Section 000 of Division J of Section fol 1.5 by any applicant for a permit subjects the applicant to a c1v1I penalty of not more than five hundred dollars {$5 ) . · an structure~ prior to its issuance, also requires the iplicant for such permi\f ,fi\fg~ signed statement thal he is ' and Prq essions Code} or that he is exempt there rom, and the basis for t all ged exemption. Any violation of ... W®@ffi@@~" @@G!IHj>@QJ§~'i?O®!Il Workers' Compensation Declaration: I hereby affirm under penalty of petjury one of the following declarations: D I have and will maintain a certificate of consent to self-Insure for workers' compens·ation as provided by Section 3700 of the Labor Code, for the performance of the work for which this pennil is issued. liJ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the perfonnance of the work for which this pennil is issued. My workers' compensation insurance carrier and policy numberaie:lnsuranceCo.. PolicyNo. -z.-z,C,--03<{ 1G.'Z.-0@ ExpirationDate /~ I-CJCf This section need not be completed if the pennit is for one hundred dollars·($100) or less. D Certificate of Exemption: I certify th a tin the performance of the work for which this permitis issued, J shall not employ any person in, any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is uni ul, and shall subject an employer to criminal penalties and civil,fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, da vlded for In Section 3706 the Labor code, interest and attorney's fees. ~ C<;lNTRACTORSIGNATURE . f; 11\1\ : DATE <. -·:t' ·~:. ': ---,.~, I hereby affirm that'/ am exempt fi'om Contractor's License Law for the fof/owin_g reason: D I, as owner of the property or my employees with wages as their sole compensation, will ~o the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law aces not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale: If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden QI proving that he did not build or improve for the purpose of sale). D l,,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Seclion .Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for,construction of the proposed property improvement. 0Yes 0No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have·contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. l,plan to provide portions of the work, but l,have hired the following person to coordinate, supervise and provide the major work (include name I address I phone/ contractors' license number): 5. I will provide some of the work, but I have conlr!!Cted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): Ji6 PROPERTY OWNER SIGNATURE DATE ' @@jj!J(i)Q,@)i'i] tr'(:Jl)§ 0@@'ijD@Rl ~®Cff (;,'J@ID0Qi{j~00rnro~o~ii t13:(!)_()11ltiOro~-~@!&'ti3JfiJJif~~(i;i< -~-,,, --~-:~ . ::,: C Is the-applicant or future buildin·g occupant required to submn a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 31 No Is the ap~l_icant or future building ~upant required to obtain a permit from the air ~llution control district or ai!:,!l!!ality management district? [)yes jg)No ls-the fac1hty to_be constructed within 1,000 feet of the outer b9undary of a school ~Ite? 0Yes ~No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED U_NLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. . . I hereby.affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certifythatl have read the application and state that the above infonnation Is correct and that the fnformJ1tion on the plans is accurate. t agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of C bad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SA VE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINSt ALL LIABILITIES, JUDGMENTS, ST D EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITYIN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for ex o r 5'0' deep and ~ition or · of structures over 3 stories in height EXPIRATION: Every penn~ issued by tt,e ilding · under the provisions of this shall expire by limitation and become null and void if the building or work authorized by such permn is not commenced within 180 days from the date of such permit or if building worl( authorized by such it is suspended or abandoned at any time after the won< is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). Ji6 APPLfCANT'S SIGNATURE DATE 4 _ J/ -08 I 111.J 11·c1r1•i• . Flilll lllldlll IISIICIIOI· Dept: Building Engineeri'ng Pl.anning CMWD St Lite Fir-el Plan Check #: Date: 06/03/2008 Permit#: CB080654 Permit Type: Tl Project Name: BEE.RY GROUP-1100 SF Tl OF Sub Type: INDUST OF EXISTING 1600 SF OFFICE/WAREHOUSE TO SAME Address: 2091 LAS PALMAS DR #0 Lot: 0 ContactPerson: NA Phone: 7608459330 Sewer Dist: CA Water Dist: CA •alllll~I 111a111 II 1111111111 I I 1111111111 II II I 1111111111111111111111111111111111111111111111111111 ltlllll 111 lllfl 11111111111111111111111111111111111111 I I 11 Inspected c. u~ Date Ap.proved: L__ Disapproved: __ ._ By: Inspected: Inspected ' \ Date By: Inspected: Approved: Disapproved: __ Inspected Date By: Inspected: . Approved: Disapproved: __ I ii I I I 11 I I 111 I 111 I I I I I I I I I I I I I I I I I I I I I I 11 I I I I I I 11 I I~ I I 11 I I I 11 I I I 811 I I I 11 I I I I I I I l'I I I I 11·1I1111111 I I I I I I I I I Ii 111 I I I I I I 11 I I I I I I I I 1111 I 111IIII11111111 It I I I I I I I I 11 I Comments: ,----------------------------------- City of Carlsbad Bldg Inspection· ·Request For: 06/03/2008 Permit# CB080654 Inspector Assignment: TP --- Title: BEERY GROUP-1100 SF Tl. OF Description: OF EXISTING 1600 SF OFFICE/WAREHOUSE TO $AME Type:i"I Sub Type: INDUST Phone: 7608459~30 Job Address: 2091 LAS PALMAS DR Suite: D Lot: O Location: OWNER SIERRA LAND GROUP INC Inspector. .:/2- Owner: SIERRA LAND GROUP INC Total Time: Requested By: NA Entered By: CHRISTINE CD Description Act Comments 19 . Final Structural AL--~----- ·29 Final Plumbing 39 Final Electrical 49 Final Mechanical ~-- Comments/Notices/Holds, Associated PCRs/CVs Original PC# Inspection History Date Description Act lnsp Comments 05/22/2008 14 Frame/Steel/Bolting/Welding AP TP 05/22/2008 34 Rough Electric AP TP DATE: 5/16/08 JURISDICTION: Carlsbad PLAN CHECK NO.: 08-0654 EsGil Corporation In (l'artnersli.ip witli. qovernmentfor()Juilaing Safety SET: III PROJECT ADDRESS: 2091 Las Palmas Dr, Suite 'D' PROJECT NAME: Office TI ~ANT ~ D PLAN REVIEWER D FILE cg] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 · The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plc;1ns transmitted herewith have significant deficiencies identified on the enclosed check list and·should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation unm corrected plans are submitted for recheck. D the applicant's copy of the check list is enclosed.for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D Esgil Corporation stciff did not advise the applicant that the plan check has been completed. [gj Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Matt Baldwin Date contacted: 5/16/08 (by: CM) Mail Telephone Fax In Person o· REMARKS: By: Chuck l,Wendenhall Esgil Corporation D GA D MB D EJ ' D PC Telephone#: In Person Fax#: Enclosures: Walk in ... ~ .... ,.,~, t I I -I I '•\ DATE: 5/13/08 JURISDICTION: Carlsbad PLAN CHECK NO.: 08-0654 EsG.il Corporation In <Partnersliip witli government for <Bui{i[ing Safety SET: II PROJECT ADDRESS: 2091 Las Palmas Dr, Suite 'D' PROJECT NAME: Office TI LJ APPLICANT ~VIEWER LJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list ar:1d should be corrected and resubmitted for a complete recheck. 1:8:] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 1:8:] The applicant's copy of the check list has been sent to: John Beery . 5751 Palmer Way, Suite G3, Carlsbad, CA 92010 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. 1:8:] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Jo9n Beery Date contactedtif .3 ( O y(b~) Mail V4relephone Fax vf n Person D REMARKS: By: Chuck Mendenhall Esgil Corporation D GA D MB D EJ D PC Telephone#: (760) 438-2963 x 121 Fax #: (760) 438-2965 Enclosures: 5/6/08 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 08-0654 5 / 13.f.,OS , · Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. NOTE: The project originally provided for mechanical ventilation in the new work area. This has now been eliminated. However, the code requires natural ventilation for work area. The source of the natural ventilation must be within 20 ft of the work area. See Title 24 Section 121 (b )1. The existing overhead door may be used but it is not within 20 ft of the all work areas. The expanded work area must have mechanical ventilation. All other previous corrections are OK END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has beeR addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. -, DATE: 4/22/08 JURISDICTION: Carlsbad PLAN CHECK NO.: 08-0654 EsGil Corporation In (J?artnersliip witli qovernment for (Bui(aing Safety SET:I PROJECT ADDRESS: 2091 Las Palmas Dr, Suite 'D' PROJECT NAME: Office TI ,JJ-APP-L~NT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: John Beery 5751 Palmer Way, Suite G3, Carlsbad, CA 92010 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: John Beery Telephone#: (760) 438-2963 :i< 1 2 .1 Date contacted: r.-f /2..z/i:,t (by: I'-) Fax #: (760) 438-2965 Mail Telephone .,._. Fax / In Person D REMARKS: By: Chuck Mendenhall Esgil Corporation D GA D MB D EJ D PC Enclosures: 4/14/08 9320Chesapeake Drive, Suite 208 -+ San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ) .) Carlsbad 08-0654 '4/22108 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO.: 08-0654 OCCUPANCY: B, M TYPE OF CONSTRUCTION: VB JURISDICTION: Carlsbad USE: Office & Mfg ACTUAL AREA: 1100 TI Only ·ALLOWABLE FLOOR AREA: no change STORIES: one HEIGHT: no change SPRINKLERS?: No REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETE;D: 4/22/08 FOREWORD (PLEASE READ}: OCCUPANT LOAD: 19 max DATE PLANS RECEIVED BY !=SGIL CORPORATION: 4/14/08 PLAN REVIEWER: Chuck Mendenhall This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances er1forced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC . . The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of tbe 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city lc:1w. To speed up the recheck process, please note on this list {or a copy) where each correction item has· been addressed,· i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. ) .__J Carlsbad 08-0654 4/22/08 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • STRUCTURAL 1. Show on the roof framing plan on sheet S-1 that the 4X6 beams supporting the new HVAC unit extend between existing 4X14 purlins as shown on S3 ( entire roof framing plan) . · 2. Detail the connection of the new 4x4 posts to the existing slab. The new framing plan on sheet AD-1. • ACCESSIBLE.PARKING • Provide the following notes cm the plans to show compliance with the current disabled accessible parking: 3. Show that accessible parking spaces comply with Section 11298.3.1 as follows: a) Single spaces shall be 14' wide and outlined to provide a 9' parking area and a 5' loading and unloading area on the passenger side of the vehicle. b) When more .than· one space is provided, in lieu of providing a 14' space for each space, two spaces can be .provided within a 23' area with a 5' loading z:one between each 9'0" wide space. c) Each space is to be a minimum of 18' in depth. 4. At least one in every 8 accessible parking spaces shall be served by an access aisle ~96" in width arid design9ted as VAN ACCESSIBLE, per Section 11298.3.2. 5. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high and located so that it is visible to traffic enforcement officials). Section 11298.3.3. .) \) Carlsbad 08-0654 4'/22/08 6, Show or note on the plans that the accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of: a) A profile view of a wheelchair with oQcupant in white on dark blue background. b) The sign shall ~70 in.2 in area. c) When in the path of travel, they shall be posted ~80" from the bottom of the sign to parking space finished grade. d) Signs may also be centered on the wall of the interior end of the parking space ~36" from the parking space finished grade, ground or sidewalk. e) Spaces complying with Section 1129B.4.2 shall have an additional sign 'Van-Accessible" mounted below the symbol of accessibility per Section 1129B.4. f} In addition, the surface of each accessible space is required to be marked with the international symbol of accessibility. • Provide the following notes on the plans to demonstrate compliance with the disabled access standards. 7. Show or note that every required passage door has ~32" clear width, per Section 1133B.2. . 8. . Show, or note, that there is a level floor or landing on each side of all doors. The floor or landing is to be ::5½" lower than the doorway threshold, per Section 1133.2.4.1. 9. Show or note that all hand-activated door op$ning hardware meets the following requirements, per Section 1133B.2.5.2: a) Latching, or locking, doors in a path of travel. are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. b) Is to be centered ~30" but S44" above floor. 10. Note that the doorways leading to sanitary facilities shall be identified, per Section 1115B.6, as follows: a) An equilateral triangle¼" thick with edges 12" long and a vortex pointing upward at men's rest rooms. b) A circle ¼" thick, 1211 in diameter at women's rest rooms. c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60". ) ,! Carlsbad 08-0654 4/22/08 e) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per Section 11178.5.1. 11. Show, or note, on the plans that the accessible water closets meet the following requirements, per Section 11158.4.1: a) The seat is to be ~17" but :::19" in height. b) The contra.ls for flush valves shall be: i) Mounted on the side of the toilet area. ii) Be S44" above the floor. 12. Show that grab bars comply with the following, per Section 1115B.4: a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. b) They shall be securely attached 33" above the floor, and parallel. c) NOTE: Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36". d) Grab bars at the side shall· be located: i) 15" to 16½" (±1 ") from the center line of the water closet stool. ii) Be ~42" long with the front end positioned 24" in front of the stool. iii) Total length of bars at the back shall be ~36". e) The diameter, or width, of the grab bar gripping surface is ~1¼" but :51½", or the shape shall proVide an equivalent gripping surface. f) If mounted adjacent to a wall, the spabe between the wall and the grab bar shall be 1½". • RECEPTION COUNTERS 13. The tops of counters shall be 28" to 34" from the floor. The disabled accessible section of counter shall be located at a section of counter that is at least 36" wide and no more than 28" to 34" high. Section 1122B.4. • ENERGY CONSERVATION 14. · Complete lighting energy form L TG-2-C. The lighting listed on this form on sheet M3 is the allowed lighting. List on this form the actual lighting based on the fixtures you intend to install. 15. Note on the plans that the roll up door at the receiving area must be completely weather stripped to meet the ef}ergy standards for air infiltration. 16. Show on the plans the ceiling and exterior wall insulation required for the new conditioned space. ,) · Carlsbad 08-0654 , 4'/22/08 17. Include as part of the energy forms the ENV-1 forms to show compliance with the energy standards for the new conditioned space. The PERF-1 form lists the envelope as not a part of this submittal. The envelope compliance for the new conditioned space must be included in the energy compliance documents. 18. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131(d). END OF REVIEW To speed up the review process, note on this list {or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank. you. -~ -- Car.lsbad 08-0654 4/22/.08 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 08-0654 PREPARED BY: Chuck Mendenhall DATE: 4/22/08 BUILDING ADDRESS: 2091 Las Palmas Dr, Suite 'D' BUILDING OCCUPANCY: B, M TYPE OF CONSTRUCTION: VB BUILDING AREA -Valuation Reg. VALUE ·PORTION ( Sq. Ft.) Multiplier Mod. Tl 1100 34.37 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by 'Ordinance j ,.. , Plan Check Fee by Ordinance _ i • I Type of Review: 0 Complete Review D Structural Only tJ Repetitive Fee -·--i • I Repeats Comments: D Other D Hourly j Hour* Esgil Plan Review Fee ($) 37,807 37,807 $313.531 $203.791 $175.58/ Sheet 1 of 1 macvalue.doc ' • ... , ! PLANNI-NG/ENGINEERING APPROVALS PERMIT NUMBER CB [0-6Gtf" ADDRESS 21}~ { LA'. f'A,~ M~ RESIDENTIAL RESIDENTIAL ADDITION MINOR < < $17,000.00) PLANNER DATE DATE 4/zif O 0 I ~lv-£-Su rrf?: .1) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING -------,--------- .ENGIN~~ DATE f2¢ 8 oocs/Mlsforms/Plannlng Engineering Approvals ~ ~ ~ -::i-~ -b\ • \j-, --:t JI .!! .!! IV IV IV Q C C r&DD ~DD ·E,J.DD !&'.JD D I PLANNING. DEPARTMENT BUILDING PLAN CHECK REVIE;W CHECKLIST , · Plan Check No. CB OIO lot; 4:: Address it>4 I L-Az PA~$ Pl<. Phone (760} 602-4675 Plc:1nner Gina Ruiz APN: ~t?,1· pi,\. l \:' Type of Project & Use: ___ , _____ \ ______ Net Project Density; DU/AC Zoning: ~M General Plan: Pl Fac;:JJ,ities Management Zone: __ s __ _ CFD (in/out) # -:-Date ~f participation: : · Remaining net dev acres: __ _ Circle One · (For non-residential development: Type of land used created by this permit: ___________________ _, Legend:. C8l Item Complete Environmental Review Required: D Item Incomplete -Needs your action YES_ NO~ TYPE_·-- DA l'E OF COMPLETION: _________ ....__ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: _______ · _______________ _ Discretionary Action Required: YES NO 'K TYPE ___ _ APPROVAURESO.NO. ____ ....__DATE __ PROJECT NO.---------- OTHER RELATED CASES:---------------------'------- Compliance with conditions or approval?· If not,-state conditi_ons which require action. Gonditionsof Approval:_-________ --___ · _--------.,.-------------- Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES __ · NO )( CA Coastal Commission Authority? ;YES __ N0.2S__ If California-Coastal Commission Authority.: Contact them at-7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Deteimiae. status (Coastal Peimit Required or Exempt): Habitat Management Plan' · .... / Data:-Entry Completed? YES_·_ NO_.,,.__. _ If .property has Habitat Type identifiecf in Table 1-1 of HMP, complete HMP Permit application and assess fees iii Permits. Plus: ·. · (A/P/Ds, Activity Maintenar:ice, -enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) . _ . . . • 4 • • " ' l t ·i' ,, f .. , ; ! lncloslonary Housing Fee req~ired: . YES _· ·_· ~o L (Effective-date of lnclusionary Housing Ordinance~ May 21, 1993.) Data. Entry·Completed? YES ___ NO_· __ _ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, . Enter Fee, UPDATE!) H:IADMIN\COUNTER\BldgPlnchkRevChkfst R!:!V 3/06 SOD rtJoo lXl D D itl D 0 I!! D D @~o Site Plan: Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easer:nents, existing and proposed structures, streets, existirg. st~eet. improvements, right-of-way width, . dimensional' .setbacks. iarid existing topographical lines· (including all side and rear .yard slopes). ' Provide legal description of property and assessor's parcel number. : > Policy 44: -Neighborhood Architectural Design Guidelines 1. Applicability: YES ____ NO · x:: . : 2. Project complies YES . NO __ _ Zoning: 1. Setbacks: Front: Required Shown ------------Interior Side: Required Shown _____ _ Street Side: Required Shown _____ _ Rear: Required Shown _______ _ Top of slope: Required Shown _____ _ 2. Accessory structure setbae:ks: Front: Required ______ Shown _____ _ Interior Side: Required Shown _____ _ Street Side1 Required Shown _____ _ Rear: Required Shown _____ _ Structure separation: Required Shown _____ _ · 3. Lot Coverage: Required ______ Shown _____ _ 4. Height: Required ______ Shown _____ _ 5. Parking: Spaces Reql!ired 0-1 . Shown __ '=3_1 __ _ (breakdown by uses for commerc!al and industrial projects required) Residential Guest Spaces Required ______ Shown _____ _ Additionai' Comments Correction #1 -Please show on Sheet 1 the total number of parking spaces provided and required on site for each use per Chapter 21.4.4. Correction #2 -Is there any proposed roof mounted equipment associated with this building permit? If so, will the equipment be screened by an existing parapet wall or is new screening material required? Please see the attached handouts for examples. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Plan Review Requirements Category: TI , INDUST Date of Report: 04-18-2008 Name: Address: Permit #: CB080654 JOHN BEERY STE G-3 5751 PALMER WAY CARLSBAD CA 92010 Job Name: BEERY GROUP-1200 SF TI OF Job Address: 2091 LAS PALMAS DR CBAD St: D Reviewed by: ~\ / ----=---------"--",o __ _ ... ~• Bl"DG. DEPT COPY INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable· codes and/ or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes_"clouded", to this office for review and approval. Conditions: Cond: CON0002726 [MET] Exit Signs shall be placed in accordance with CFC 1011.1. Indicate on egress plan AND electrical sheets. Exit signs shall be illuminated internally or externally. CFC 1011.2 Entry: 04/18/2008 By: cwong Action: AP TITLE 24 REPORT Title 24 Report for: Berry Tl Office I Storage 2691 Las Palmas Carlsbad, CA 92010 Project Designer: Beery Group Inc. 5751 Palmer Way, Suite G-3 Carlsbad, CA 92010 (760) 438-2963 Report Prepared By: Julie A. Gustine GMS I M_urphy Mechanical 140 Vallecitos de Oro San Marcos, CA 92069 (760) 591-9172 Job Number: 08-03.1635N Date: 4/29/2008 The EnergyPro computer program has been used to perform the i::alculations summarized in this compliance report. This program has approval and is authorizec;f by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC -www.energysoft.com. EnergyPro 4.3 by EnergySoft Job N_umber: 08-03.1635N City of Carlsbad i:.l!i•G••h•i•l=i·tiiillt§hl APPLICATION FOR UNREASONABLE HARDSIDP EXCEPTION TO STATE OF CALIFORNIA DISABLED ACCESS REQUIREMENTS (EXISTING BUil,DINGS; CHAPTER 31, DIVISION III, Sec. 3112A.(a) ex. 1.) When existing buildings are remodeled and, when the valuation of the modifications is less than approximately 93,000 dollars, the California State Building Code allows relief from some accessibility requirements when the cost of compliance with those regulations is disproP9rtionate. Disproportionate cost is defined as when the cost of all compliance requirements except mandatory me.asures exceeds 20% of the cost of the project. Where the cost of alterations necessary to fully comply is dispropo.rtionate, access shall be provided to the extent that it can without incurring disproportionate costs. In other words, accessible elements must be provided or upgraded to a maximum cost of 20 % of the project valuation. Priority for providing access should be given in the following order: A. An accessible entrance, B. An accessible route to the aitered area, C. At least one accessible restroom for each sex, D. Accessible telephones, E. Accessible drinking fountains, and F. When possible, additional accessible elements such as parking storage and alarms. NOTE: SEE CHAPTER 31, DIVISION Iii, CALIFORNIA BUILDING CODE FOR MANDATORY REQUIREMENTS AND THE COMPLETE TEXT OF THE REGULATIONS FOR ACCESS COMPLIANCE IN EXISTING BUILDINGS. ****************************************************************************** DOCUMENTATION OF UNREASONABLE HARDSHIP: PLEASE PRINT ProjectAddress: 2091 Las Pal:rhas Dr. #D PlanCheck#: CB 080654 Proposed Use: General Off ic.e/Wa_rehouse -..... _:., ·At'. Signature:_~-::J,,--Hfl'---,-----------,------~-------------- Rev 3-20-01 1635 Faraday Ave11ue • Carlsbad, CA 92008~7314 • (760) 602-2700 • FAX (760) 602-8560 @ Please print Name Beery Group Inc. Arch i tee t WORKSHEET FOR DISPORPORTIONATE COSTS !.PROJECT VALUATION (Per City Engineer) 2.VALUATION OF OTHER AREAS WITH SAME PATH OF TRAVEL (Total valuation dating back to January 26, 1992) 3.TOTAL OF LINE 1 & 2 $31,807.00 -0- $37.807.00 IF LINE 3 EXCEEDS THRESHOLD AMOUNT ($93,132. FULL COMPLIANCE IS REQUIRED IF LINE THREE IS LESS THAN THRESHOLD AMOUNT, COMPLETE WORKSHEET. 4.ESTIMATED COST OF UPGRADING ENTIRE PATH OF TRAVEL 5.PROPORTIONATE COMPLIANCE COST 2 0 % (Divide line 4 by line 3) 6.ENTER TWENTY PERCENT OF PROJECT VALUATION 7.MINIMUM COMPLIANCE COST OBLIGATION (Lesser of lines 5&6) $.25,300.00 $ 5,060.00 $ 7,561.40 S 5,060.00 INDICATE BELOW HOW COST OF COMPLIANCE OBLIGATION WILL BE SPENT .. . ~ ITEM ESTIMATED COST Accessible Parking & Entrance Accessible H.C. Bath Reception Desk for H.C. $ 760.00 $ 1,400.00 $ 2,900.00 $ 5,060.00 SIGNATURE OF APPROVING AUTHORITY: ---.lMi---~--tt-Fl--~-.,.~--·-_-_-:._-:_-:_--_____ _ TITLE: ~0e-~· 1.J_,_j~e,-_, ---Ma~-/G,'-------- PLEASE ATTACH TIDS DOCUMENT TO THE APPROVED PLANS FOR THE USE OF THE BUILDING INSPECTOR AND THE CONTRACTOR. THANK YOU Rev 3-20-01 CB080654 2091 lAS PALMAS DR D BEERY GROUP-1200 SF Tl OF OF FXl8TINr.: 1Rm ~F ()FFlr.FIIIIIAPr::1-1()1 rc:::r:: Tn C:::AAAr:: 4/11 jos -m C....I~ F,f!E 4-E::S&-\L ~ ~ d. "OAUCL+: o~ ~e c!e.-t'2.tm 1 ~e..d --If $00 p (!_ 4e...e ~ (__ ~ ~~· ~ hwd6h,~ -+-o U.!>,L.L f~s~~ ff/4Pic. r-12,orf:P¼f lf(?O (08--1);sa'b/.ec{ /Jr-cce's~ mus.+ b_ base,:;,{ ON project ualua."HoN 0t,f37, 8-07 te,v-Mf? Jg /4~ y,2-(5~ YjY-/t,1~ ~t,2f; djYZJl/47' i\ sts-Jvs ~ :rr-~ pQ, ) ·):f>-07 ~&;f t)t-nt _ - ,S-\\'i lu~ {) lo.~ @) fj Yl<.e.. ~: . . ~----{l e_ f 9roV~ ~ ~ )./ ~ /ZTT-~ N LO~-. 5 /J,l{ tJt ~§CX<P - Annroved Date By ) Building S-/1t;1:1/0l{ £L~ --- Planning s/5'/0g (/_/_ - ~-/ Engineering 7".;?9""-Qf"' ~ ,,,. Fire I 0 ~-,-/Jf Jrh r ,, ,. Health / ~ HazMat/ Air Quality , Comments Date Building 1/-72,, 'i--1.5 Planning 'l-.25" Engineering Fire Forms/Fees Sent Rec'd Due? By School ___ y N <;:FD y N PFF y ~-/ P•E&M 4111Jog ¥-JI y (.N} " flt Special lnsp: I y N J' Fire y N Se;ver ---y N : f~~;complete -:1,11-0....,~----------- ~pp1ication & Rela:;j:,:cs. Complete-------~ .....