HomeMy WebLinkAbout2091 LAS PALMAS DR; D; CB991007; Permitv43a5 .. City of Carlsbad 04/22/1999 Commercial/Industrial Permit Permit No: CB991007 Building Inspection Request Line (760) 438-3101 Job Address: 2091 LAS PALMAS DR CBAD St: D Permit Type: Tl Sub Type: Parcel No: 2130611600 Lot#: Valuation: $38,752.00 Construction Type: Occupancy Group: Reference #: INDUST 0 VN Status: Applied: Entered By: ISSUED 03/16/1999 RMA Project Title: 04/21/1999 ADD/REMOVE WALLS,CEILING,ELECT Plan Approved: Issued: 04/22/1999 Applicant: . Inspect Arecm91 04/22/99 0001 01 ~!~~~"N0~GROUP INC C-PRMT JOHN GROTH STE 211 163 AVENIDA CHAPALA SAN MARCOS CA 92069 760 754-8191 /4 ~'0,.t:N BMND BLVS 1010 ~ GkENQ~E%J (Q)\S '91z'efa-=J{'\J'<f' . I~-~-~~~ I (I ~) '-~ ... "' -~/1/ AJ\ ~ . l Builtling _P~rmit . !\ ~ $333.0j ·-.... -:>-. c( W~ter C~:-'F.eee; Add'! Bwlding Permit Fee ~ $0~81 ~-· etef S1ze~ctl 1 Plan Check $216l4v/i fdll R~61:@ater1Con. Fee> I Add'I Plan Check Fee ~$0:od'~ kgi=1,D P~b«0i/ I , J Plan Check Discount $0:oor::s: fgij~ ~ / Strong Motion Fee $8/lf '\ BfF-(CFD F7uncl) . : Park Fee~~ $0:00 lNCORflfioelfse Tax ,-..,......_i . t Iv , i952 ./ \ "·. , LFM Fee '\._ \ ~~0.00'--._·tf-lCe_l:!§..e--l'ax,{~~'30nd) Bridge Fee , . <J $0~QO Traffic tq;ipadt ~ee BTD #2 Fee "" J$ __ 6(oq/) R (rra~tmpa'ct,(eFD yund) STD #3 Fee ~ $0:o@l (Fj U) \J:S v / Renewal Fee $0.0Q_ PtlJMl3f~,..TOTAL Add'I Renewal Fee $0.00 --Et:Ee-TRICAL TOTAL Other Building Fee $0.00 MECHANICAL TOTAL Pot. Water Con. Fee $0.00 Master Drainage Fee: Meter Size Sewer Fee: Add'I Pot. Water Con. Fee $0.00 TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $127.40 $117:60 $0.00 $20.00 $0.00 $0.00 $292.05 $1,114.69 Inspector:~ FINALAPPROVAL Date: S-,&7 ff1 j I . Clearance: _____ _ NOTICE: ·Please take NOTICE thatapproval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.• You have 90 days from the datE! this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forthin Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this or as to.which the statute of limitations has oreviouslv otherwise exoired. CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 02 898-22 V v 55q/ ~ ,PERMIT APPLICATION PLAN CHECK .CITY OF CARLSBAD BUILDING DEPARTMENT .2075 Las Palmas Dr., Carlsbad CA 92009 (760) 438-1161 EST. VAL. --..,4.IJ~-l-~==---...,,...-,.4 Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units 72GT19:IL Proposed Use Name Address City State/Zip Telephone# 7fiti:trt:;1Jtfliiii&:~2:1iii/~;i?jjijjfil·:~,?!ifii;1Bf).~~~rt1iic.a~'i:1l[A1£·?ri!J1i{?t?i;i~3~:;~ Name ·====r-«'. Address City S.tate/Z1p I Telephone# !s; .. }'.QQfl!l'ltA9:tQJb ffiM.~Mx:N~M'f:'"'.'~ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its i'ssuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, com.mending with Section 7000 of Division 3 of the Business and Professions Code] or"tt,at he is exempt therefrom, and the basis for the alleged exemption. Any violation of ection 7031.5 by any applica t for a per'Jit s~jl;Fts the ffePlic1;1nt to a civil penalty of not more than five h dre dollars [$5001). t> A--L ;11,4-,: ~ e.e . '.i',11,/l'~L ·CM-. J4. SlfAI/IIU0.s q UI, 7&o ?3 -7 2- Name Addr!)ss City · . State/Zip Telephone# State Licen~e # 73 / Z J./ 7 License· Class 'Js City Business License # ( \ 4,' '7 0 72,,,, Designer Name Address City State/?:ip Telephone State License# _________ _ ~.:::.V,,(QRKl;:,li~J;~OMl;'J;l'{~ATl.9t,I, ~ ... ~: .:..'.." . :::: .... ,;,_,_ .: .. · .. ~',: · ::,:'; ,-::-__,, _:_,_:.;}_~ii;;l' <, '.;,;;,::.:.::Ei.::,, C':~T,\. {-!.;":,,:?·''::;..:.c;,/: ;;·,If.Yo,:~.;;,:-.,~'£;:;':'.-:.:,:;; Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have ;:ind will maintain a certificate of consent to self-insure for workers' compensation a~ provided by Section 3700 c;,f tl'!!l Labor Code, for the performance of-the work for, which this permit is issued. lSa' I have -and will maintain workers' compensation, as required by Sectio~ 3700 of the Labor Code, for the performance of the work for which this permit is ~ed. My worker's compensation insurance carrier and policy number are: . Insurance Company____________________ Policy No .. ____________ Expiration Date _______ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this per,mit is issued, I shall not empJoy any person ·in any manner so as fo become subject to the Workers' Compensation Laws of California. · · • WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an, employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorn!ly's fees. SIGNATURE _____________________________ DATE ________ _ }ff?-:OWNER~BtiltDE1:LbECLARAt1QN V '~--,,,.,,_, ' ';,v*_' :;d _.:,/:,-, , w ~ ·,sfr-~· :----~_~,':':-1,t,'""~;:,~,:--7:p~:' ·t: !'·-~:. ,\:-,, ~~:--;~J ;;_,.,~~~ 'I hereby affirm that I am exempt from the Contractor's License Law for the follqwing.reason: · 0 I, as owner of the property or my employees with wage~ as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Prc;,fessions Code: The Contractor's License Law does not apply_to an c;,wner·of property -who builds or improves thereon, and who does , such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is ·sold within one year of completion, the owner-builder will have the burden of proving that he did not. build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an· owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the_ Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materi~ls for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an applic·ation for a building permit for the proposed work. 3. I have contracted, with the following person (firm) to provide the proposec;! construc:ti.on (include na.me / address / phone number / contractors license number): 4. I plan to provide portions of the work, bot I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): · 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): _______________________ --'-----'----"---'------------'------------------ PROPERTY OWNER SIGNATURE _____ -'------~-----------DATE !!5 .. Q'M.P~J;!._Ul:!!($E(?I!QflJ'QJ!-/IJ!(l1f~(P§!J..Il.N. .. ~11Jlll'i~.;f:'~'™1-»[Qfl!tY, _d~::~ .... ;L . .t=t_, .. ', ... ::,;,.;;.,~;::-;;;:::-;:;-::-_:;,,;;:; .. ,;;;;;.,,;:,,:;::,,,·,~,.;;::::::::;:::;:::_ C:'JJ;;fC<",,':..,_,,, ls the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the-Presley-Tanner Hazardous Substance Account Act? 0 YES ~ NO Is the applicant or future building occupant required to obtain a permit from the. air pollution control district or air quality management district? 0 YES lZJ. NO ls the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES ~ NO IFANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND,HE.AIR POLLUTION CONTROL DISTRICT . . ts •. ,,. ':<(()l($.:trul,Q_TIQ~:!;,WP}~~g~N9,,L7::i~z,=.:.: :.:..:::;'.' :.:-::. . :, --:7~: ~-,.:.:, ... :.:=:::::iZJ:~·:·:<; .. ,,;.,: ... .;J~~:;;:;_:;:_. ;.;-::.,:,.:;;.,;:::J, :.~;-:;:7.; :\<:--~'!Z·~-~:'.'ZJ:'~'.7_'r;j ·. I herel;>y affirm that there is a construction lending agency fo,r the performance of the work for yvhich this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS. ~I~l~:< ;ARP~~A~x;p_r;,nfte~T~QN;,-:;;jj >~' ;\:i~;; _'._;'YJ·:~f;-~L::~,>v'._~-.. ~--~~-)M~,A~~~ ,,i-,_:::.,.:._,{= ... =, .. ~:::._.:; __ :::(=:i-u.::::,_:;:~t=,:..~::;;J~==-,"_;;::.J,;::',::;;:~:;::_z;=~,;=i'\~=;;.;"""'=, ~:::: __ =, .=,=-r=:,_«:;;';;=::,-= .• ,:;;,~:;;::~=;:;::dh;:::~:,=-}-==~~;::L::,,;;:;,:::=\~=~;_::;;~=;~~::;_;,.,,=zr=<~::~r=:::_r=..::·=0_,,_,,=,=~:;;:";::~=::-~=~;;::~=-,-~::-:::::: I certify that I have read the. application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. ~, hereby authorize representatives of the Cit\' of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of-structures over 3 stori~s in height. EXPIRATION: Every .permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not t;:ommenced witliin 3 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned-at any time after the rk is-cornrne e fa ii p riod-o 180 days ection 106.4.4 Uniform Building Code). APPLICANT1S SIGNATURE --t'---6-<fhrp:.<-,;.+,-ff-.L...!..--;t'-r-'-'-~~~4--r-------DATE ;'J -//J -9? PINK: Finance City of Carlsbad Inspection Request Permit# CB991007 For.~f Title: ADD/REMOVE WALLS,CEILING,ELECT Description:, Type: Tl Sub Type: IN DUST Job Address: 2091 LAS PALMAS DR Suite: D Lot O Location: ~PPLICANt : JOHN GROTH Owner: SIERRA LAND GROUP INC Remarks: Total Time: CD Description Act Comments Inspector Assignment: PD --- Phone: 7608391722 Inspector:~ Requested By: MARK Entered By: CHRISTINE 1.9 Final Structural £-----~------- 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Inspection History Date De~cription 5/4/99 19 Final Structural 9/3/99 89 Final Combo 4/23/99 16 Insulation 4/23/99 17 Interior Lath/Drywall 4/23/99 84 Rough Combo Act lnsp Comments co PD co TP SEE JOB CARD AP PD AP PD AP PD Es·Gil Corporation 1.n Partnersliip Witli (jovernment for '.Buifaing Safety DATE: 4/21/99 · JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1007 SET:11 ~P-~~NT O...J..lJ.fil.S;/ CJ PLAN REVIEWER CJ FILE PROJECT ADDRESS: 2091 "D" Las Palmas Dr. PROJECi NAME: Native Threads Tl • ihe plans transmitted herewith have been corrected where necessary and substantially comply D D. D D D II D D with the jurisdiction's building codes. · The plans transmitted herewith will s1.Jbstantially comply with the juriscJiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclo.sed for the jurisdiction to forward to the applicant contact person. The appli<?ant's. copy of the check list has been sent to: '- Esgil Corporation staff did not advi_se the appl_icartt that the plan -check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: telephone #: Date contacted: (by: ) Fax#: Mail Telephone Fax In Per$on REMARKS: By: Mike Puckett EnclostJres: Esgil Corporation D GA D MB D EJ D PC 4/12/99 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 •• , • ... )i, EsGi_.1 Corporation 1.n Partnersliip wit/i (jovemment for '13uifaing Safety DATE: 3/30/99 JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1007 PROJECT ADDRESS: 2091 "D" Las Palmas Dr. PROJECT NAME: Native Threads TI SET:I D APPLICANT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. • The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The-applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. II The applicant's copy of the check list has been sent to: John Groth 3355 Mission Ave. Ste. 211 Oceanside, Ca. 92054 • Esgil Corporation staff did not adyise the applicant that the plan check has been completed. D Esgil Corpon:~tion staff did advise the applicant.that the plan check has been completed. Person contacted: bate contacted: (by: ) Mail Telephone Fax In Person D REMARKS: By: Mike Puckett Esgil Corporation D GA D MB D EJ D PC Telephone#: Fax#: Enclosures: 3/18/99 · trnsmtl.dot 9320 Chesapeake Drive, Suite 208 +· San.Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 .,;, Carlsbad 99-1007 3/30/9.9 PLAN REVIEW CORRECTION UST TENANT IMPROVEMENTS PLAN CHECK NO.: 99-1007 OCCUPANCY: B/Fl TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: R1=MARK8: DATE PLANS RECEIVED BY JURISDICTION: 3/1.6/99 DATE INITIAL PLAN REVIEW COMPLETED: 3/30/99 FOREWO~D (PLEASE READ): JURISDICTION: Carlsbad USE: Office/Warehouse ACTUAL AREA: l,384sfTI STORIES: 1 HEIGHT: OCCUPANT LOAD: 11 TI DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/18/99 PLAN REVIEWER: Mike Puckett This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is bqsed on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire .Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1994 USC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code·, the approval of the plans does not permit the violation of any state, county or city law. · To speed up the recheck process, please note on this list (Or a .copy) where each correction item has been address·ed, i.e., plan .sheet number, specification section, etc. Be sure to enclose the marked. up li~t when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENT~ WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot Carlsbad 99-1007 3/30/99 1. 'Please make all corrections on the origin~I tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building-Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 921-23, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGjl Corporation is complete. 2. Please note in the ProjeGt Data whether or not the building is sprinklered. 3. Please revise the occupancy group to show Office/Manufacturing groups B/F1. 4. · If the adjacent Suite E is indeed an F2 occupancy then show on the plans that a full 1 hr. occupancy separation wall is existing or will be constructed between Suite E and the proposed tenant improvement space. Please detail the construction and fire protection of the wall. 5. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1994 UBC, UMC and UPC ~nd 1993 NEC. 6. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all chemicals, dusts and hazardous . materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from _ hazardous materials. Section 307.1.6. 7. Provide notes and/or details to show that the floor and wall finish in toilet rooms are· surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing -shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 807. 8. Please show the mechanical-exhaust for the restroom to provide a minimum of one complete air change every 15 minutes. Carlsbad 99-1007 3/30/99 9. Please revise the wiring methods shown to exclude the use of AC cable and per the City of Carlsbad request please note on the plans that "No AC cable or Romex wiring methods are allowed". 10. Show water heater size, type -and location on plans. UPC, Section 501.0 Please note if it is new or existing. Show the routing of the P& T drain to the outside if applicable for the water heater shown. To speed up the review process, note on this list (or a copy) where each correction i.tem has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where th.ey are .iocated in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes o No D The jurisdiction has contracted with Esgi[ Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review·items1 please contact Mike Puckett at Esgil Corporation. Thank you. Carlsbad 99-1007 3/30/99 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1007 PREPARED BY: Mike Puckett DATE: 3/30/99 BUILDING ADDRESS: 20.91 "D" Las Palmas Dr. BUILDING OCCUPANCY: B /Fl TYPE OF CONSTRUCTION: VN I BUILDING PORTION I BUILDING AREA I VALUATION I VALUE (ft.2) MULTIPLIER ($) . Tenantlmprovement 1,384 28.00 38,752.00 .. . . Air Conditioning ' . . Fire Sprinklers TOTAL VALUE 38,752.00 . D 1994 UBC Building Permit Fee • Bldg. Permit Fee by ordinance: $ 333.03 ·o t994 UBC Plan Check Fee • Plan Check Fee by ordinance: $ 173.18 Type of Review: 0 Complete Review D Structural Only D Hourly D Repetitive. Fee Applicable D Other: Esgil Plan Review Fee: $ 216.47 Comments: Sheet 1 of 1 macvalue.doc 5196 I ~:Carlsbad 99-1007 .3/30/99 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Mike Puckett PLAN CHECK NO.: 99-1007 (Revised 3/31/99) DATE: 3/30/99 BUILDING ADDRESS: 2091 "D" Las Palmas Dr. BUILDING OCCUPANC)': B/Fl TYPE OF CONSTRUCTION: VN BUILDING PORTION BUILDING AREA VALUATION VALUE (ft,2) MULTIPLIER ($) Tenant Improvement 1,384 .28.00 38,752.00 - . Air Conditioning · Fire Sprinkle.rs TOTAL VALUE 38,752.00 D 1994. UBC Buiidirig Permit Fee • Bldg. Permit Fee by ordinance: $ 333.03 D 1994 UBC Plan Check Fee • Plan Check Fee by ordinance: $ 173.18 216.47 Type of Review: D Complete Review D Structural Only D Hourly D Repetitive Fee Applicable D Other: Esgil Plan Review Fee: · $ 216.47 173.17 Comments: Sheet 1 of 1 macvalue.doc 5196 City of Carlsbad M #i Ii·•• ,144 I• ,I-ii •14 •Li I;; ,14 Ii I BUILDING PLANCHECK CHECKLIST DATE: lf/ 7 /t'J9 PLANCHECK NO.: CB 99/cro 7 BUILDING ADDRESS: r9.07' I ct) . ¼S? aJ¾ p \) r. PROJECT DESCRIPTION: --L-·=~~·------------------ ASSESSOR'S PARCEL NUMBER: cf2l'3,.. «G J -I-fa EST. VALUE: ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have supmitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this qffice to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. Cl Right-of-Way permit is required prior to . construction of the following improvements: Please see the attached report of deficiencies marked wi~Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to ,this office for review. ~h .> Date: By: Date: -------- By: ________ Date: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: , D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist 0 Right-of-Way Permit Application D Right-of-Way Permit Submittal Checklist . and Information Sheet D Sewer Fee Information Sheet Date: ENGINEERING DEPT. CONTACT PERSON Name: JOANNE JUCHNIEWICZ City of Carlsbad Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Phone: (619) 438-1161, ext. 4510 CFO INFORMATION Parcel Map N9: Lots: Recordation: . Carlsbad Tract: A-4 H:1woR01c2©",9"Ss~faetm~e~.F~-arlsbad, CA 92009-,576 • (760) 438-1161 • FAX (760) 481~69 ti 0 0 ti BUILDING PLANCHECK CHECKLIST SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines B. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets G. Driveway widths 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards qn adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography 3. Include on title sheet: A. Site address · B. Assessor's Parcel Number C. Legal Description For commercii:)1/industrial buildings and. tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing sguare footage of different uses (manufacturing, warehouse, office, etc.) previously approved. · ~ .. ·-.. r.irl""'I-,,.,,..., •. .,. ---=--...._ ,___.. .........,_\J? v·~~\.)~ . . cp--4.. • EXISTING PERMIT NUMBER DESCRIPTION DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. __ ...,..... ____________________ _ 4b. All conditions are in compliance. Date: --'---------- H:IWORDIDOCSICHKLSnBulld1ng Plancheck Cklst BP0001 Fann JJ.doc 2 Rev. 12/26196 :J ,,C ,i __ , ~ i a. o BUILDING PLANCHECK CHECKLIST DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the ·building site is required for all new buildings and for remodels with a valae at or exceeding $ ______ , pursuant to Carlsbad Municipal Code Section 18.40.,030. Dedication required as follows: ________________ _ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 ½" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the · Engineering Department in person; Applications will not be accept by mail or fax. Dedication completed by: ------,-------Date: ___ _ IMPROVEMENT_REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ _ , pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: _ ____. __________ _ Attacf:led please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: _________ _ Date: ___ _ 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ _______ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as f<?llows: H:IWORDIDOCS\CHKLSMuilding Plancheck Cklst Bf'0001 Form JJ.doc 3 Rev. 12/26196 1sv 0 a 0 0 0 o. 0 0 0 0 0 0 0 0 BUILDING PLANCHECK CHECKLIST 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: ·6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 .. 06.030 of the Municipal Code. ?a. Inadequate information availqble on Site Plan to make a determination on grading requirements. Include accl!rate wading quantities (cut, fill import, export). 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: .The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: ---------- 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) 7d.No Grading Permit required. ?e.lf grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF~WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into Pl:lblic storm drain, sewer and water utilities. Right-of-Way permit required for: H:IWORD\DOCSICHKLSnBuilding Plancheck <::klst BP0001 Fonn JJ.doc BUILDING PLANCHECK CHECKLIST 4 Rev. 12/26/96 CJ CJ CJ 9. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. 10. INDUSTRIAL .WASTE PERMIT If ybtJr facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You m~y telephone (760) 438-2722, extension 153, for assistance. Industrial Waste permit accepted by: Date: 11. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City ~ngineer prior to issuance of grading or building permit, whichever occurs first. 12. ~ed fees are attached CJ No fees required .Additional Comments: Fe.££ Cf1/\:y,c:,d: fu. ".Yfes?£-0cl k::-:::rt:v\ X'. P::C!"--'Y LL/W: ±<::;e. ~re,.y-0>:::s VA~ d ~ 8 1Pa...u <......,c....S _"'--crv--z4r- ~ 'a rv-e §xec! ,.+.,. H:IWORD\OOCSICHKLSnBuilding Plancheck Cklst BP0001 Fonn JJ.doc 5 Rev. 12126196 . I ENGINEERING DEPARTMENT -FEE CALCULATION WORKSHEET ' , O _,.....e$timate based on unconfirmed information from applicant. av'" Calculation based on bu\lding plancheck plan submittal. Address: dffl.( Q ( 9'8 -w.~. /)r Bldg. Permit No. C'\? '79/6l>7 Prepared by:~:3T,._______ Date: lf /JE;'/t:fl Checked by: ----'----Date: ____ _ EDU CALCULATIONS: Lis~es and square footages for all uses. Types o~!':-~ ~q.~U~~} ------EDU's: • / S --~-- Types of Use: -------Sq. Ft./Units: ----------EDU's: ----- ADT's: _---z_7 __ _ Types of Use: ------'---Sq. Ft./Units: ------ADT's: ------ FEES REQUIRED: WITHIN CFO: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) ~ f)lr. PARK-IN-LIEU FEE PARK AREA & #: ___ _ FEE/UNIT: ____ _ fuAFFIC IMPACT FEE X NO. UNITS: __ _ x FEE/ADT: 3 5 ADT's/UNITS: __ 7..__ ____ *3. BRIDGE AND T~OROUGHFARE FEE (DIST. #1 DIST. #2 X FEE/ADT: ___ _ ZONE:.__,.,...-:.-....- =$ J}( r =$ d'-/5- DIST. #3 _.) =$ rt[ I ADT's/UNITS:_-,----t 4. FACILITIES MANAGEMENT FEE ~ , UNIT/SQ.FT.: X FEE/SQ.FT./UNIT:. ___ _ =$ ef 7 ~ 5. SEWER FEE PERMIT No. ________ _ EDU's: •IS. X FEE/EDU: {f,51{ BENEFIT AREA: G. DRAINAGE BASIN: ----.-- EDU's: o JS t 6. SEWER l,ATERAL ($2,500) -~ 7. DRAINAGE FEES PLDA. ______ _ ACRES: _____ _ X FEE/EDU: ?3 = $ __ , 3_-~· _?_s_ =$_-,,:;:;:-.(5 __ 7 HIGH ___ /LOW __ _ X FEE/AC: ___ _ =$_--r',6""-·--1 TOTAL OF ABOVE FEES•:$ 5 3 k VS *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. P:\DOCS\MISFORMS\FEE CALCULATION WORKSHEET REV 7/13/98 ~ ~ -----. 1{21~ ~io-'t r a, io 0 >, .0 (") 'It ti a, .c (.) (.) C: C: C: ro ro ro c:: a: a: PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Checkllf;; 1f_;: /{){) 7 Planner J~e-t_ APN: ::J_ I 3 -Db f -I Co Address 2:!?c;,f l4'5 /41-vn ~Ile Phone (619) 438-1161, extension c./J:73 Type of Project & Use: :@f{;'LA Zoning: y.H__:-Q General Plan: Net Project Density: ______ D_U~/A~C-.f.:1:--Facilities Management Zone: -"""_saa...~-- CFD lin/n11tl # __ Date of participation: Remaining net dev acres: Circle One ------- (For non-residential development: Type of land used created by this permit: _____________________ ) Legend: ~ Item Complete (QJ Item Incomplete -Needs your ac~ion D D Environmental Review Required: YES NO TYPE DATE OF COMPLETION: ______ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: D D Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. _____ DATE ___ _ PROJECT NO. ---------- OTHER RELATED CASES: __________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ------------------------ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact them at -3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. D D lnclusionary Housing Fee required: YES __ NO (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y /N, Enter Fee, UPDATE!) Site Plan: ~D ~D D 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. D 2. Provide legal description of property and assessor's parcel number. Zoning: DD 1. Setbacks: Front: Required -------Shown -------Interior Side: Required -------Shown -------Street Side: Required -------Shown -------Rear: Required -------Shown ------- D D 2. Accessory structure setbacks: Front: Required -------Shown ------- Interior Side: Required -------Shown -------Street Side: Required -------Shown -------Rear: Required -------Shown -------Structure separation: Required -------Shown D D 3. Lot Coverage: Required -------Shown ------- D D 4. Height: Required Shown ------- DD 5. Parking: Spaces Required _______ Shown ______ _ Guest Spaces Required ______ Shown ______ _ Additional Comments -ffep::ev CJ5 E I '/ f?,,t)-5e_ <? ~ /17 . OK TO ISSUE AND ftNTERED APPROVAL INT COMPUTER Carlsbad Fire Department 990108 2560 Orion Way Carlsbad, CA 92008 Fire Prevention (760) 931-2121 Plan Review Requirements Category: Building Plan Reviewed by: Date of Report: 03/26/1999 ------------ Name: John Groth Address: 3355 Mission Av Ste 211 City, State: Oceanside CA Plan Checker: Job,#: 990108 Job Name: Native Threads ~9100;:s_ Job Address: 2091 Las Palmas Ste. or Bldg. No. D ·~ Approved D Approved Subject to D Incomplete Review FD,Job# The item you have submitted for review has been approved. The approval is based on plans, information and I or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 990108 2nd FD File·# 3rd Other Agency ID "I •.. ., . TITLE 24 REPORT FOR: Native Threads 2091D Las Palmas Dr. Ca:i;lsbad, CA. PROJECT DESIGNER: Groth Architects 708 Civic Center Dr. Oceanside, CA. 92054 760-754-8191 REPORT PREPARED BY: Jeanne Fricot, CEA Hayn.al & Co., Inc. 2171 India St. Ste. A San Diego, CA. 92101 619-531-1122 Job Number: Date: 3/2/1999 TITLE 24 CONSULTING HVAC DESIGN The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, llc (415) 883-5900. 425 W. 5th Ave., Ste. 201 • Escondido, CA 92025 (760) 743-5408 Escondido• (619) 531-1122 San Diego• (714) 573-4065 I '' Table Of Contents for Title 24 Report Cover Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Form ENV-1 Envelope Certificate of Compliance ....................... 3 Form ENV-2 Prescriptive Envelope Summary ............................ 5 Form ENV-3 Construction Assemblies !" ••••••••••••••••••••••••••••••••• 9 Form LTG-1 Lighting Certificate of Compliance .... · ................... 13 Form LTG-2 Prescriptive Lighting Compliance Summary ................. 15 ·CERTIFICATE OF COMPLIANCE -Envelope (part 1 of 2) ENV-1 page 3 of 15 ----------------------. ------------.--------------------------------------- Project Name: Native Threads Address: 20·910 Las Palmas Dr. Carlsbad, CA. Envelope Designer: Groth Architects Documentation: Haynal & Co., Inc. !Date: 3/2/1999 , _______ _ !Building Permit No , _______ _ !Checked by/ Date I jCOMPLY 24 User 2875 -------------------------------------------------------------------------- GENERAL INFORMATION Date of Plans: Building Type: Nonresidential Building Conditioned Floor Area: 399 sf Climate Zone: 7 Phase of Construction: O New Construction 'f--Addition O Alteration Overall Envelope Method of Envelope Compliance: Prescriptive - STATEMENT OF COMPLIANCE This Certificate of Compliance lists the B~ilding features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the Calif- ornia Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the documentation is ' accurate and complete. DOCUMENTATION AUTHOR Jeanne Fricot, CEA Certificate# 92-95-613 ~1-4-~.I _,;_A_A._ -_ ·_ ·&d..;._ __ ~ ___ 03-03-1999 (~ (Date) The Principal Envelope Designer hereby certifies that the proposed build- ing design represented in this set .of construction documents is consistent with the other compliance form~ and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in sections 110, 116 through i18, and 140, 142, 143 or 149 of Title 24, . Part 6, Chapter 1. Please check one: ~ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer or architect. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. Q I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section ____ of the Code to sign this document as the person responsible for its preparation; and for the follow~ng reason: ______________ _ PRINCIPAL ENVELOPE D~SIGNER Groth Architects 760-754-8191 ENVELOPE MANDATORY MEASURES c-::zc ()e:} (Lie. #) Indicate location on plans of Note. Block for Mandatory Measures: '3-/tJ-qq (Date) CERTIFICATE OF COMPLIANCE -Envelope (part 2 of 2) Project Name: Native Threads Documentation: Haynal & Co., Inc. ENV-1 page 4 of 15 !Date: 3/2/1999 I !COMPLY 24 User 2875 -----------·------------------------------------------------------------- Const OPAQUE St.T.RFACES Assembly Name Type Location/Comments R-11 Demising Wall(MTL) Metal R-0 Demising Wall (MTL) Metal DEMISING CEILING Metal Carpeted Slab On Grade None FENESTRATION Frame Orient Pan~s Type Exterior Shade OH Glazing Type Note to Field f CVERALL· ENVELOPE METHOD (part 1 of 4) Project Name: Native Threads Documentation: Haynal & Co., Inc. WINDOW AREA TEST A. Display Perimeter B. Gross Exterior Wall Area C. Gross Exterior Wall Arec!, D. Enter Larger of A or B E.. Enter Proposed Window Area 0.0 ft X 6 ft = 460.0 sf X 0.40 = 460.0 sf X 0.10 = If Eis greater than D Qr less than C, proceed to for will.dow area adjustment. If not, go to part 2 1. If Eis greater than D: D. Maximum Standard Area E. Proposed Area N/A I N/A 2. If Eis less than C: C. Minimum Standard Area E. Proposed Area 46.0 I 0.0 SKYLIGHT AREA TEST ENV-2 page 5 of 15 !Date: 3/2/1999 I !COMPLY 24 User 2875 0.0 sf Display Area 184.0 sf 40% Area 46.0 sf Min Std Area 184.0 sf Max Std Area 0.0 sf Proposed Area the next calculation of 4. Window Adjustment Factor N/A Window Adjustment Factor 0.0000 Atrium Height 0.0 ft If Height< 55 ft Sta.Il.dard = 5% If Height>= 55 ft ----------+----------Standard= 10% A. Gross Exterior Roof Area B. Enter Proposed Skylight Area V 399.0 sf X 0.05 20.0 sf Standard Area 0.0 sf Proposed Area If the Proposed Skylight Area is g'reater than the Standard Skylight Area, proceed to the next calcµlatioh for the skylight area adjustment. If not got to part 2 of 4. 1. If Proposed Skylight Area> Standard Skylight Area: Standard Skylight Area N/A I Proposed Skylight Area N/A Skylight Adjustment Factor N/A OVE~L'ENVELOPE METHOD (part 2 of 4) ENV-2 page 6 of 15 --------------------------------------------------------------------------- Proj~ct Name: Native Threads Documentation: Haynal & Co., Inc. JDate: 3/2/1999 I !COMPLY 24 User 2875 -------------------------------------------------------------------------- OVERALL HEAT LOSS PROPOSED Adj. STANDARD Assembly Name Area HC U-Val UxA Area U-Val UxA ----------------------------------------------- R-0 Demisiµg wail(MTL) 296. 0 1.1 0.413 122.3 296.0 0.189 55.9 R-11 Demising Wall(MTL) 164.0 1.1 0.192 31.6 164.0 0.189 31. 0 DEMISING CEILING 399.0 0.3 0.045 18.1 399.0 0.078 31.1 No Glazing 0.0 N/A 0.000 0.0 29.6 1.230 36.4 No Glazing 0.0 N/A 0.000 0.0 16.4 1.230 20.2 ------------ Total 172.0 Total 174.6 ** OVERALL HEAT LOSS COMPLIES PROPOSED UA <= STANDARD UA ** OVERALL' ENVELOPE METHOD (part 3 of 4) ENV-2 page 7 of 15 , -------------------------------------' --------------------------------------- Project Name: Native Threads Documentation: Haynal & Co., Inc. OVERALL HEAT GAIN Glazing North North WF 0.34 0.34 PROPOSED Area SC H 0.0 0.00 0.0 0.00 ** OVERALL HEAT GAIN COMPLIES V OHF Total Total 0.0 0.0 0.0 jDate: 3/2/1999 I jCOMPLY 24 User 2875 STANDARD Area RSHG Total 29.6 0.94 16.4 0.94 Total 9.5 5.2 14.7 PROPOSED HG<= STANDARD HG** ·OVERALL· ENVELOPE METHOD (part 4 of 4). Project Name: Native Threads Documentation: Haynal & Co., Inc. Win~ow Area Adjustment Calculations Wall Name Demis:i,ng Wall Demising Wall 2 Gross Dir Area N N TOTALS 296.0 164.0 4.60. 0 Skylight Area Adjustment Calculations Roof Name R-19 CEILING Gross Dir Area H TOTAi,S 399.0 399.0 Door Ar~a 0.0 Window Area ------ 0.0 0.0 ------ 0.0 Skylt Area ------ 0.0 ------ 0.0 ENV-2 page 8 of 15 jDate: 3/2/1999 I jCOMPLY 24 User 2875 Adjusted Adjust Window Wall Factor Area Area ------------------ 0.0000 0.0 296.0 0.0000 0.0 164.0 ------------ 0.0 460.0 Adjusted Adjust Skylt Roof Factor Area Area ------------------ 0.0000 0.0 399.0 ------------ 0.0 399.0 ·PROPOSED CONSTRUCTION ASSEMBLY Project Name: Native Threads Documentation: Haynal & Co. , Inc., COMPONENT DESCRIPTION ------------------------------· Sketch of Construction Assembly ASSEMBLY U-VALUE Construction Components Outside Air Film 1. Gypsum or Plaster Board 2. Iµsulation, Mineral Fiber, 3. Gypsum or Plaster Board 4. 5. 6. 7. 8. 9. Inside Air Film R-11 ENV-3 page 9 of 15 JDate: 3/2/1999 I !COMPLY 24 User 2875 Assembly Name: R-11 Demising Wall{MTL) Assembly Type: Wall Assembly Tilt: 90 deg (Vertical) Framing Material: Metal Framing ·spacing: It o.c. Framing Percent: 15.0 % Absorptivity: o . o·o Roughness: Smooth Plaster, Metal Th R-Value Fr (in) Cavity Frame 0.17 0.17 0.500 0.45 0.45 .* 3.500 11.00 11. 00 0.500 0.45 0.45 0.68 0.68 -----·------------------------------------------------------------------ Weight: H,eat Capacity: Unadjusted R-Values 12.75 0.00 TOTAL U-VALUE = 0.192 TOTAL R-VALUE = 5.20 4.3 lb/sqft 1.11 'PROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 10 of 15 --------c ----------------------------------------------------------------- Project Name: Native Threads !Date: 3/2/1999 I Documentation: Haynal & Co., Inc. !COMPLY 24 User 2875 --~--------------------------------------------------------------------- COMPONENT DESCRIPTtON Assembly Name: R-0 Demising Wall(MTL) Assembly Type: Wall Assembly Tilt: 90 deg (Vertical) Framing Material: Metal Framing Spacing: II 0.C. Framing Percent: 15.0 % Absorptivity: 0.00 Sketch of Construction Assembly Roughness: Smooth Plaster, Metal ASSEMBLY U-VALUE Th R-Value Construction Components Fr (in) Cavity Frame '-------------------------------------------------------------------------- Outside Air Film 1. Gypsum or Plaster Board 2 .. Air Space 3~ Gypsum or Plaster Board 4. 5. 6. 7. 8. 9. Inside Air Film We:j.ght: Heat Capacity: 0.500 * 3.500 0.500 Unadjusted R-Values 0.17 0.45 0.85 0.45 0.68 2.60 TOTAL U-VALUE = 0.17 0.45 0.85 0.45 0.68 0.00 0.413 ===== TOTAL R-VALUE 2.42 4.2 lb/sqft 1.08 "PROPOSED CONSTRUCTION ASSEMBLY ENV-3 page 11 of 15 --------------------------------------------------------------------------- Project Name: Native Threads Documentation: Haynal & Co., Inc. COMPONENT DESCRIPTION I I I I I I I 1. I I I Sketch of Construction Assembly ASSEMBLY U-VAL'Uli! Construction Compon~nts Outside Air Film 1. Air Space 2. Insulation, Mineral Fil:;>er, R-19 3. Acoustical Tile, Interior Finish 4. 5. 6. 7. 8. 9. Inside Air Film jDate: 3/2/1999 I jCOMPLY 24 User 2875 Assembly Name: DEMISING CEILING Assembly Type: Roof Assembly Tilt: O deg (Horizontal Roof) Framing Material: Metal Framing Spacing: II 0.C. Framing Percent: 10.0 % Absorptivity: 0.00 Roughness: Concrete, Asph. Shingles Th Fr (in) 2.000 6.000 0.500 R-Value Cavity Frame 0.17 0.78 19.00 1.43 0.17 0.78 19.00 1.43 0.61 Unadjusted R-Values 0.61 21. 99 0.00 Weight: Heat Capacity: . 0.9 lb/sqft 0.25 TOTAL U-VALUE = 0.045 TOTAL R-VALUE = 21. 99 ·PRDPOSEn CONSTRUCTION ASSEMBLY ENV-3 page 12 of 15 --------------------------------------------------------------------------- Project Name: Native Threads !Date: 3/2/1999 I Documentation: Haynal & Go., Inc. !COMPLY 24 User 2875 ------------------------------------------------------------------------- COMPONENT DESCRIPTION ----------------------------- I I I I I I I I I I I I I I I I I I I. I I I Sketch of Construction Assembly ASSEMBLY U-VALUE Construction Components Assembly Name: Carpeted Slab On Grade Assembly Type: Floor Assembly Tilt: 180 deg (Horizontal Floor) Framing Material: None Framing Spacing: "O.C. Framing Percent: 0.0 % Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Th R-Value Fr (in) Cavity Frame ------------------------------------------------------------------------- Outside Air Film 1. E~rth 2. Concrete, 140 lb, Not Dried 3. Flooring, Carpet and Fibrous Pad 4. 5. 6. 7. 8. 9. Inside Air Film 24.000 3.500 0.250 0.17 4.00 0.28 2.08 0.17 4.00 0.28 2.08 0.92 Unadjusted R-Values 0.92 7.45 7.45 ADJUSTMENT FOR FRAMING (1 / 7.45) X (1.00) + (1 / 7.45) X (0.00) Weight: Heat Capacity: 210.9 lb/sqft 42.19 0.134 TOTAL U-VALUE = 0.134 TOTAL R-VALUE 7.45 ·cBRTIFIC~TE OF COMPLIANCE -Lighting (part 1 of 2). LTG-1 page 13 of 15 ----------------------------------------· ---------------------------------- Project Name: Native Threads Address: 2091D Las Palmas Dr. Carlsbad, CA. Lighting Designer: Groth Architects Documentation: Hayna1 & Co., Inc. !Date: 3/2/1999 , _______ _ !Building Permit No , _______ _ jchecked by/ Date I !COMPLY 24 User 2875 -------------------------~------------------------------------------------- GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 399 sf Building Type: Nonresidential Phase of Construction: O New Construction Method of Lighting Compliance: Prescriptive Climate Zone: 7 'f-Addition O Alteration STATEMENT OF COMPLIANCE This Certificate of Compliance lists the Building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the Calif- ornia Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENT~TION AUTHOR Jeanne Fricot, CEA Certificate# 92-95-613 ~ {·~~)ff~A-...-__ ~~~---_-___ 03-03-1999 ~) (Date) The Principal Lighting Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with t-he other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in sections 110, 119, 130 through 132 and 146 or 149. Please check one: O I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer electrical engineer or architect. O I affirm that I am eligible under the e,xemption to Division 3 of the Business a1+d Professions Code by Secti0n 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the ~usiness and Professions Code by Section ____ of the Code to sign this document as the person responsible for its preparation; and for the following reason: ______________ _ PRINCIPAL LIGHTING DESIGNER Groth Architects 760-"-754-8191 LIGHTING MANDATORY MEASURES (Signature) (Lie. #) Indicate location on plans of Note Block for Mandatory Measures: (Date) )( 'CERTIFICATE OF COMPLIANCE -Lighting (part 2 of 2) LTG-1 page 14 of 15 ------------------------------------------------------------------------- Project Name: Native Threaqs Documentation: Haynal & Co., Inc. !Date: 3/2/1999 I !COMPLY 24 User 2875 -------------------------------------------------------------------------- INSTALLED LIGHTING SCHEDULE No of Name Lamp Type Lamps ------------------- Fluorescent 3 MANDATORY AUTOMATIC CONTROLS Control Watts/ Lamp ------ 34 Ballast Ballasts/ No of Note to Type Luminaire Fixt. Field -------------------------- Standard 1. 5 5 Note to Control Location ID Control Type Zone Controlled Field CONTROLS FOR CREDIT Control Control Location ID Control Type Zone Controlled Note to Field •LIGHTING COMPLIANCE SUMMARY LTG-2 page 15 of 15 ----------------------------------:---------------------------------------- Project Name: Native Threads !Date: 3/2/1999 I Documentation: Haynal & Co._, Inc. !COMPLY 24 User 2875 ACTUAL LIGHTING POWER No of Watts Total Name Description Lumin per Default Watts 48" T-12 Low Watt /3 Lamp (Tandem) 5 108.0 Y 540.0 SubTotal 540 Less Control Credits (LTG-3) o Total Proposed Watts 540 * If not CEC Default value, please provide supporting documentation. ALLGWED LIGHTING POWER BY ZONE Allowed Floor LPD Total Tailored Zone Name Occupancy Area (w/sf) (watts) (watts) -----------------------------------------' - OFFtCE AREA Office 399 1.600 638 0 -------------------- TOTALS 399 1.600 638 0 * Note: Tailored Allotment requires supporting documentation on form LTG-4. " ,., MANDATORY REQUIREMENTS ENVELOPE MANDATORY MEASURES (NONRESIDENTIAL) 1 .. Exterior manufactured doors, windows, and fenestration products shall meet the infiltration and U-value certification requirements of Section 116(a). 2. Site-construced doors, skylights, and windows shall be caulked and weather-stripped per Section 116(b). 3. All joints and openings which are potential sources of air ieakage shall be caulked, gasketed, weather-stripped or otherwise sealed to limit infiltration and exfiltration per Section 117. 4 .. Certified insulation materials per Section 118(a). 5. Urea Formaldehyde foam insulation installed per Seqtion 11 B(b ). 6. Insulation installed to meet flame spread and smoke density reqt1irements per Section 118(c). LIGHTING MANDATORY MEASURES 1. Each enclosed area shall have independent controls (per Section 131(a) and exceptions). 2. Lighting shall be uniformly reducible by one half in areas which are greater than 100 sf, exceed 1.2 watts/sf, and have more than one luminaire (per Section 131 (b) and exceptions; exceptions include lights in corridors). 3. Daylit areas l1:1rger than 250 sf shall be separately controlled and uniformly reducible by one half (per Section 131 ( c) and exceptions). 4. Separately metered spaces 5,000 sf or greater shall .have alJtomatic shutoff controls (per Section 131 (d) and exceptions). 5. Display lighting shall be separately switched on circuits that are 20 amps or less (per Section 131 (e), no exceptions). 6. Exterior lighting controlled from a lighting panel within the building shall be automatically controlled (per Section 131 (f) and exceptions). 7. Pairs of one-lamp and three-lamp fluorescent luminaires shall be tandem-wired where reasonable (per Section 132 and · exceptions). AUU/Kt:MUVC VVM.LU:::t,VC:.ILll'll~,t:..L.1-....., 1 ?Ji/fr-. (tJ' LJ11c, Ctry ,,;-;t'~ - /4iil( ~ _A-,-u-,,)T ~ -~1 CJ Ccwl ;Vd cY/..,. 3/30( q 1 CU// 4/8/9Cf Ch; @ {U;ks 4/1/C/9 &,;: ~.JZ tu~~--fo a~( ~Y-zr.lli-v ~"fu 1'7/1~ ~ hre . I \ Tl INDUST •~~~~~~ ENGINEERING ~ FIRE APPR/FORM 0, ~ HEALTH DEPT -----HAZ MAT/ AIR QUAL OTHER SEWER DISTR -----BLDG GRADING LETTER L1/f Ll-14CJ LL-vi <:(' <:>I --1 A ~'/ /} 1/M ~:U /lf)_µ s¼ ;iM TO r• -.· .. ; -I, / / / I nty ~ vf J IU..f_;(-{.{:Y. S' r-rr:--V . . b. ~t;"@:. APPLICANT ,!., -.: ;_ !:',ANT · ·'-/4 Bs~( ak pv p04f &d-L/ _ ~io.>~Jf~q; I ~~:c~0R~ /'~JA.Jl log~ _---1, ___ SCHOOLFORM (.fall( I -----4-__ CFDFORM .. t , j /',"",_l,. CJ\ _, PE&MWORKSHEET 4/t<p/qq uvrv;II ~ ~ _ ___. __ stoGFEEscoMPLe:re L,1(],((11-· rn~ ;vd-/r_,_,j ~ f?/4~( <2· r:~ Y(v-(c;q~ " ... .,