Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2091 RUTHERFORD RD; ; CB013138; Permit
··11-15-2001 '·Job Address: ·:.':.:Permit Type: :;: .. parcel No: _:;· Valuation: \ \ ... : · Occupancy Group: : .· ·Project Title: Applicant: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB013138 Building Inspection Request Line (760) 602-2725 2091 RUTHERFORD RD CBAD Tl Sub Type: COMM 2121202500 Lot#: O Status: $108,300.00 Construction Type: NEW Applied: Reference #: Entered By: CARLSBAD TECH CENTER Plan Approved: STAIRWELL TO EXIST MEZZANINE, WALLS & CEILING Issued: Inspect Area: Owner: ISSUED 10/02/2001 JM 11/15/2001 11/15/2001 WARE MALCOMB 103 56665 OBERLIN SAN DIEGO CA 92121 858-638-7506 FARADAY CENTER LL C C/0 CHARLES ABDI 7330 ENGINEER RD SAN DIEGO CA 92111 (i.1'~,, C:GF= .~.7-02 ! • w •.. : .,-. f : ~ ' ; -:":'_:! ... ,. i . ', ' ~ .. · ~ Total Fees: $990.30 Building Permit Add'I Building Permit Fee Plan Check · Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee STD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee . /2 /_. lnspecif ~ Total Payments To Date: $373.28 $574.28 $0.00 $373.28 $0.00 $0.00 $22.74 $0~00 $0.00· $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF · PFF (CFO Fund), License Tax Lic(:)nse Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) PLUMBING TOT AL ELECTRICAL TOT AL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES FINAL APPROVAL $617.02 '· _ _,,/ ----(l'·o:uo"' $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $0.00 $0.00 $0.00 $0.00 $0.00 $990.30 Date:/--22---o L--Clearance: ____ _ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.• You have 90 days from the date this permit was i~sued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been oiven a NOTICE similar to this or as to which the statute of limitations has previously otherwise expired. l iA:5n3~s PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Business Name (at this-address) Uni~ Phase No. Proposed Ui,eA.st # of Bedrooms Total # of units 9P6C. # of Bathrooms (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not , ore than five hundred dollars [$5001). ' l '1 i / t "\ State License # __,$-.-_..?l_,,~""'""3';'-''f')'-<->$""'-' __ City ate721p .~ -" "" / ill 373:28 City Business License # -'-"""""'-"""'-"'~,._'-,/· Designer Name Address City State/Zip State License#--'------~---!aT-c::;'NORKE~ENSAT(oN"'~-·:---_, --~:"'""'~-·:,·,,77-·_:--:: ~--;"--! ~ 'k':,,, -.: 0''' \..' ,,<': ',.',:, --:-, :---."-::' Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Telephone 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: / / Insurance Company -5\-41'£ (1M..~n@J fuJf)a Policy No. -1U/&&/t)/ Expiration Date c:J-/o// ,!;'"'2_ (THIS SECTION NEED NOT BE COMPiiTED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) / / ti CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as tq become subject to the Workers' Compensation Laws of California. WARNING: Failur to sec e work compensation coverage ls unlawful, and shall subject an employer to criminal pena ies and civil fines up to one hundred thousand ~ollars ( , &,00 , in a • i to the cost of com ensation, damages as provided for in Section 3706 of the Labo code, i terest and attorney's fees. SIGNATUREc.,-~US~~====~~:::l--------z> , ~::.]>WNia:~iilt.tli'..QEQ~l!A:l'IQt(, ~,::·-:?~--'. ', :-:::~:~_-_:::,!:' ·: "~I~~~·":":::·:::~::,:2~;: "'Y, , __ ;;_;_"'c;.,_,~,,_,,,.,,,,, I hereby affirm that I am exempt from the Contract r's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law·does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving-that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Seption -----,---Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed-property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted,with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________ ~------------------------ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work):, ________________________ __,---------..,...~--------------------- PROPERTY OWNER SIGNATURE_~-----------~~-------DATE_.,---------- ;~Q.M,R~§:'.t:f!J~ ,S!=Pt!Qf!fl)J:l)l(gN•/lj'~(Qgf{17A~Jl\,JJ~OJt{~!ltl;filvl!:T~QJ~,l(,Y,-;;, ,~ ,_, ,, ,, ',: <,.: ::~:;;.,; ,·:,w:-:i.:t'~di:E\ ,:Ld:-::1'.L ,','''',-,-,,,• ,<~,,-.••:,,,-..,-_, '<,'"" ;,, Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for~r risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES ild'N0 Is the applicant or future building occupant required to obtain.a permit from the air pollution control district or ai quality management district? 0 YES ~O Is ttie facility to be constructed within 1,000 feet of the outer boundary-of a school site? 0 YES IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY-NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE f!EQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~CQNSts1.1or101lteNi51NGA""Gfficv .. _::: __ ,,:. -:2,,,_ · _r:-_ -_ :::.~'"":': '\: :,::ir--,,:~---'. -·',, ':--:::-~~:r';J:"., . R::-~·~5':!'.;\·:>:,-_,p-_._ ;f,,_.;r_,-,---:-Y-7 z:.<;;; ,I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME::;:::;;:;;::;;;;:;;;:::::::::::::::::::;;::::::::=:::=::::-:;:;::::;:;:::::::::::::::::: LENDER'S ADDRESS i~.(;:,:''. 'A'ef!l:!CAN't•G!;,~Jl!;,lQAJJ.9.N. ,t:::~:-;;.:·_:;::"::;:;.=,1,,,=.,:::: __ =,.=,.:::, ____ ,-_:;::_::.,.-=-,;.~~;.,,.O.:f:;.-;;,-:::::;:::;:=::;::;;;:;::;::;;:;;:;:;:;;:::;:;:::=;:::;:;;:;::::::=::;::::;:::::;::::;;:;-::;:;:::~~-,,,:;:;"':;:'::::,~-'~~,~!-;:;:C.;. I certify that I have read the application and state that the above inform11tion is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned -property for inspection purposes. I ALSO GREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, C:OSTS AND EXPENSE WHI AY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. ions over 5'0" deep and demolition or construction of structures over 3 stories in height. OSHA: An OSHA permit is required fo e EXPIRATION: Every permit issued b authorized by such permit is not co ding Official under the provisions of this Code shall expire by limitation and become null and void if the building or work ce within O days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is co r pe o f 180 days (Section 106.4.4 Uniform Building Code). DATE --.l,_O_•i_1_fl_( ____ _ YELLOW: Applicant PINK: Finance UNSCHEDULED BUILDING INSPECTION ..,. DATE _· (-(!,,... tJ '2--INSPECTOa. ____ z_.-...f:_.....,_ __ _ PERMIT# Crj O ( · 3 f j 8' .· PLAN CHECK# ___ _ JOBADDRESS d-09/ /?urrfe/lhil{) i<D ----------------.------ DESCRIPTION __ ....,..._-------,--.--------- CODE DESCRIPTION ACT COMMENTS t1 f,AI~ 1- lnspe,ction List • Permit#: CB013138 Type: Tl Date Inspection Item 01/18/2002 89 Final Combo . 12/28/2001 19 Final Structural 12/20/2001 14 Frame/Steel/Bolting/Weldin 12/20/2001 44 Rough/Ducts/Dampers 12/19/2001 84 Rough Combo 12/05/2001 17 Interior Lath/Drywall ( 12/03/2001 14 Frame/Steel/Bolting/Weldin 11/28/2001 16 lnsl.llation 11/28/2001 17 Interior Lath/Drywall 11/21/2001. 14 Frame/Steel/Bolting/Weldin 11/21/2001 34 Rough Electric Tuesday, December·oa, 2002 COMM Inspector Act PD AP PS co PD AP PD AP PD co : PD AP PY AP PY AP PY PA PD AP PD AP CARLSBAD TECH CENTER STAIRWELL TO EXIST MEZZANINE, WAL Comments CEILING OK ONE SIDE (OFFICE SIDE) PARTIL WALLS Page 1 of 1 Citv ol Carlsbad · Flnal Bulldlna 1ns1ectlon Dept: Building Engineering Planning CMWD St Lite Fire Plan Check#: Date: 12/27/2001 Permit#: CB013138 Permit Type: Tl Project Name: CARLSBAD TECH CENTER Sub Type: COMM Address: Contact Person: Sewer Dist: STAIRWELL TO EXIST MEZZANINE, WALLS & CEILING 2091 RUTHERFORD RD Phone: CA Water Dist: CA Lot: 0 ·························································································································································· ~;,pected 71!. ~~:~ected _l_~-~-·v,_/4_a; __ Approved: ~approved: __ Inspected Date By: ___________ Inspected: ______ Approved: __ _ Disapproved: __ Inspected Date By: Inspected: ______ Approved: __ _ Disapproved: __ .......................................................................................................................................................... , Comments: _______________________________ _ EsGil Corporation 'in Partnersliip witli (jovemment for 'Buiuling Safety DATE: October S-1, 2001 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3138 PROJECr ADDRESS: 2091 Rutherford Road SET:Ii D APPLICANT ~._:. D PLAN REVIEWER D FILE PROJECT NAME: Shell Building(Office Encl & Stair)) for Tech Center [:8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact per.son. D The applicant's copy of the check list has been sent to: · [:8J Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant-that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person D REMARKS: By: ~ert Domingo Enclosures: . Esgil Corporation D GA D MB D EJ D PC Log trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92.123 + (858) 560-1468 + Fax (858) 560-1576 : /' EsGil Corporation 'ln Partnersliip Witli (jovemment for '.BuiMing Safetg DATE: Octc;>ber 29, 2001 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3138 SET:I ~ (;ANT JURIS.0 Cl -REVIEWER Cl FILE PROJECT ADDRESS: 2091 Ruth~rford Road PROJECT NAME: Office Encl and Stair to -Exist'g MeZZanine for Tech Center D D D D D The plans transmitted herewith have been ·corrected where necessary and substantially comply with the jurisdiction's building codes. - The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Jack Carter 5665 Oberlin Drive, Ste. 103, San Diego, CA 92121 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Jack (~, M .) Telephone #: (858) 638-7277 Date contacted: 101 zC}/o (by:~) Fax #: (858) 638-7506 Mailv' Telephonev Fax./ In Person REMARKS: By: Bert Domingo Esgil Corporation O GA o MB o EJ o PC Enclosures: 1 Q/18/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 .., Carlsbad 01-3138 Octob'er 29, 2001 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 01-3138 OCCUPANCY: B TYPE OF CONSTRUCTION: V N ALLOWABLE FLOOR AREA: SPRINKLERS?: Yes JURISDICTION: Carlsbad USE: Office ACTUAL AREA: 3610 SQ FT STORIES: TWO HEIGHT: OCCUPANT LOAD: . REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE-INITIAL PLAN REVIEW COMPLETED: October 29, 2001 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/18/01 PLAN REVIEWER: Bert Domingo This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, .Fire Department or other departments. Clearance from those departments may be required prior to th~ issuance of a buildjng permit. Code sections cited are based on the 1997 USC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be·in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or-city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot Carlsbad 01-3138 October 29, 2001 1. Please make all corrections on the original tracings and submit two new complete sets of prints, to: The jurisdiction's building department. 2. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed.·Susiness and Professions Code. This will be checked when all the items below are met. 3. In areas where the occupant load is at least 30, two exits are required. See . Table 10-A. 4. Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served. Section 1004.2.4. 5. Exits shall not pass through kitchens, store rooms, or spaces used for similar purposes. Section 1004.2.2. The existing warehouse is a space similar with store room. 6. Show that exits are lighted with at least one foot candle at floor level. Section 1003.2.9.2. • MISCELLANEOUS 7. The conference room should have different occupant loading than the office area. Please see item 3 above. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are l~cated in the plans. Have changes been made to the plans n_ot resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California.92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation. Thank you. Carls~ad 01-3138 October 29~ 2001 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3138 PREPARED BY: Bert Domingo DATE: October 29, 2001 BUILDING ADDRESS: 2091 Rutherford Road Bl,JILDiNG OCCUPANCY: B TYPE OF CONSTRUCTION: V N BUILDING AREA Valuatio·n Reg. CITY VALUE PORTION ( Sq. Ft.) Multiplier Mod. . Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance / ... j Plan Check Fee by Ordinance . I .., I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee =8 Repeats Comments: D Other D Hourly · I Hour * Esgil Plan Review Fee ($) 108,300 108,300 $574.281 $373.281 $321.601 Sheet 1 of 1 macvalue.doc PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Business Name (at this addres Unit No Phase No. Total # of units 7iitl. Proposed us; LA-L.f- 1,-C?r> ii 9P5C--• # of Bedrooms # of Bathrooms Name :' Address . . City. Sta~Zip ~hone # Fax # l"J @t~mr~'lN:::,r~~@fi,t}tfFiJffl_~,:I7;~f~?:~&~~ft!gft(tf!f~::,~~~"#1ftt/ Name Address Ci{y State/Zip Telephone# ~~~~P.fkW$f/~El!~~1:r!t;JJJ,-i,~1lJJi!;:~~~w,::;:;,}FJ!ilfllf?J,~,~~s:l!!lJIJ*~:-~ifd;l!JfitiqlfJ Name Address City State/Z(p Telephone# ;s~;C:~!'iffll~'f"QjI~ISQMRA.~.i'~M~?ilg~~~~~rt~:\'::f.~i~nrt~i:~z'ffiffJfi:n't~~~;:.;§;/w!i":t~~~~\~~!J~!~lF,'{~~ifM;,t;~j\t¥:!tt~~ (Sec. 7031.5 Bus)ness and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for ·such permit to file· a signed sta~ement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Name Address City State/Zip Telephcne # State License # _________ _ License Class _________ _ City Business License # _______ _ Designer Name Address City State/Zip Telephone State License # ------,-----,- tP~liW~hJ'~Jt~k:lQijffElf'JA/fiJlN~~~i~!;~'?;~~~1-l~2t~J;{fff!][~J~!~~~~~f~\~~~~~~~1i~~\!~~~:_~~fgil~;'~~~-¾{\~~~,~;~}~lG1~~i\~ Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: · 0 l'have and will_ maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work .for which this permit is issued. 0 I have and will maintain workers' compensation, ·as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and.policy number are: Insurance Company ___________________ -__ Policy No. Expiration Date _______ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this·permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and sha!I subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fee_s. SIGNA:rLJRE. _________________________ ~------------DATE _________ _ :;17~~~6J~tlE~;JiUJL):f~tQ-E:GJ:i;R~ffQN;~~~Yt1f~~if~~~~a:1~~{t~~tl~f/1~Ei)~i~~~1~~ii;it1~r~~i~fttJ;~~~\~:~~fS,.i,+,r4~1~:· :. .. _-J;P.1;;:~!}~r~~~};Zi_J,.;-_. 1=<t:-~-~\f:it~~~~fi½ti I hereby affirm that i am exempt from the Contractor's License-Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, ·wm do the work and the structure is not intended or offered for sale (Sec. 7044, Business· and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he die;! not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License· Law does not apply to an owner of property who builds or improves there9n, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have fhave not) signed an application for a building permit for the proposed work. 3. I havi;, contracted With the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan·to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ___ ...a...----'---'---~------------------------------------ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work);._-------------------------------------'------------------------ P.R0PERTY OWNER SIGNATURE _____ --------------'-----,-------DATE ________ _ :~,~~j-~~M~~:~~-Ep~~~~-~~ID·~C~~f: ~~:--~~~-' -~~ ~·:~~~·-~ Is the applicant or future building occupant required to submit a business 11lan, acutely ha:i;cirdolls materials registration for~r risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous·Substance Account Act7 0 YES 10'" NO Carlsbad Fire Department 013138 155,lu.-O(_ 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report: _1_11_15_12_0_0_1 _______ _ · Building Plan Reviewed by: Name: Ware Malcomb Address: 5655 Oberlin Drive Suite 103 City, State: San Diego CA 92121 Plan Checker: Job#: 013138 ------- Job Name: Carlsbad Tech Center Bldg#: CB013138 ---------------------------Job Address: 2091 Rutherford Rd. Ste. or Bldg. No. IZI Approved LJ Approved . Subject to LJ Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable co_des and standards. Please review carefully all comments attached as -failure to comply with instructions in this report can result in suspension of permit to consfruct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 01~138 2nd FD File# 3rd Other Agency ID PLANNINC/ENGINEERlflC_A~R-OltA-LS------__ , .PERM!TNUMBERCBQ/' >1.J/J. .DATE /lier ADDRESS __ f!JeJ:r __ · _f---"/li...--'v!e~-~&.~£..~vj__ ___ -_ ,,__,k_lJ __ · ___ _ _"RESIDENTIAL RESIDENTIAL ADDITION MINOR . ~ -. . - < < $10,000.00) DoCS/~lstorms/Plannrng Engineering A00rova1S ---------------- ~ '._. ... _ Puw,l CAMINO -REAL CARLSBAD COMPANY STORl:S VILLAGE FAIRE COMPLETE OFFICE BUILDING DATE . /l' Y--O I ------- DATE. ((~/01 __ ....;...;.._...;__ __ --. ------. ----- ------~------- CONSULTlNG STRUCTURAL ENGINEERS 3430 Irvine Avenue O Newport Beach, California 92660 (949) 263-J 308 FAX (949) 263-J 310 STRUCTURAL CALCULATIONS for Carlsbad Technical Center (Stair Addition) Carlsbad, California September 2001 KLT #01096 Ctb6/ 313<8 L KLT CONSULTING STRUCTURAL ENGINEERS 3430 Irvine Avenue, Newport Beach, CA 92660 Tel: (949).263-1308 Fax: (949) 263-1310 PROJECT DATE SHEET I OF _______ _,__________ ---------- 6 H-~Afl... d) '/..-:, 4'~ I A W1 tJ 61 l11--1 ~ !::- 'lf-1,A:¢f-°'::: tZ ui I ~ L-~4-ot, p(J--1JV1 o~ l7 . 1--&,'5' ol+ ~,4-rz, ;> x---1 i ' A lot--19 l11-.J E. O, ~ 1ft 1,rt11~31oti L-&4t'3/ pruVIDE.P ~I :·. Oz) pL-eat?-: D14pHrti141 t1 ,s t?)tA4 A-l?t-1 -&~~ C~) tkl--cu LA-fl .?'1'1> CALC. BY_-__ JOB ____ _ POOR .QUALITY ORIGINAL S KLT CONSULTING STRUCIURAL ENGINEERS 3430 Irvine Avenue, Newport Beach, CA 92660 k ~~) 263~1308 Fax: (714) 263-1310 ~ e-~prz DATE /f?, £1:,1& SHEET f ll OF __ . CALC. av ____ Joa 9kt24'4- wre,f'x.'75/ ·, := ~e,#'< t:E,4-o-#-/1 ~)(~I . I I •• ; •• : _J . ! . j ., ·:·~=1 . . .. ; . : -i ' :·· .. ·,··I ... ····! ; . ·i ) ......... j ' ... ···--"" I , · .. · .::.1 . ·i·.-1 . ! I ' ! I . ·-··1 j···· . -; . ···/ ... ·_1 C.5 To F : t3t:Pq1# I/ -====~=e..===. ~~1==@=#:=et1=o•r-=r.====fj==4LtF=l'l'iW~~"-· · l :.i.~.~ ..i ..... ··=:. ! .. . ' I . ' ' ' I .. "! . ·: ! • • 1 ; KLT CONSULTING STRUCIURAL ENGINEERS 3430 Irvine Avenue, Newport Beach, CA 92660 Tel: (714) 263-1308 Fax: (714) 263-1310 ------------------------------DATE _______ SHEET f ~'2.-OF ___ _ ---1k~b114,+f__,f2..:;....~/ ___________________ cALc.ev _____ Joa _______ _ = , I I /!!35 X 0. /8,2, ~ 14587' 15811 <t;,fof' 0 ••••• t . i : .! 14e,e,'71x 4o 1 ~ x le!>51 ,. ' ... : .1. ;.~+·: ., '.: - -, ·I l ,-i i .. ! ........ : .I . I ' : I ... --.. ~ .: ·! . ··-. -: j .. _:., :~::.: ' ' I . ' ---r---i "l '"j - -:z ::S CL r::J. ~ Lg =td. ~ -,I 'lJ ~ -::x::: ~ ' a: ~ ~ -~ ~ .ill ;--....> ---···6 o~k=.ii. .. _ ..... L<6··,·1 h---=-,~·E===---:-· 74· i ;:J, r~~--~~ l I I © ___ ____., © @ .@ @ ! I KLT CONSULTING STRUCTURAL ENGINEERS 3430 IRVINE AVENUE NEWPORT BEACH, CA 92660 949-263-1308 949-263-1310 (FAX) E-MAIL: KLTNB@AOL.COM Title: Dsgnr: Description : Scope: Rav: '510:ioo U...: ICW-060~33, Vu 5. 1.3, iz-lllo-1999, mo3l _(ci 1983-99 BNBRCALC Single Span Beam Analysis Description (E) FLOOR DIAPHRAGM ANALYSIS - I General lnfonnation - Center Span Left Cantilever Right Cantilever I Uniform Loads On Center Span ... #1 I Que_ry Values Center Location Moment Shear Deflection B Summary Moments ... Max + @ Center Max -@ Center @Left Cant @Right Cant Maximum-• I Sketch & Diagram 120.00 ft ft ft Moment 9f Inertia Elastic Modulus Beam .End Fixity Oil Left Cantilever ... 1,000.000 in4 29,000 ksi Pin-Pin 0.613 k/ft #1 k/ft 48.000 ft Left Cant 0.000 ft 1,058.20 k-ft 0.00 k-ft 7.44 k 0.00 k -93.80525 in 0.00000 in I Shears ... 1,103.40 k-ft at 60.12 ft @Left 36.78 k 0.00 k-ft at 120.00 ft @Right 36.78 k 0.00 k-ft Maximum 36.78 k 0.00 k-ft Deflections ... @ Center -98.620 in 1,103.40 k-ft @ Left-Cant. O.QOO in @Right Cant 0.000 in 0-4#4 HI n In m I 11 In m 11 mm Im I JI nm 0-613kilt r 36.lk Vux. JoA .. ~-~ 1204 "J Mmlx • l,103.4k•ltat60:121t Dau• -118.620lnat60.121tfnmloA 36.lk Job# Date: 2:02PM, 24 SEP 01 Page On Right Cantilever ... #1 k/ft Right Cant 0.000 ft 0.00 k-ft 0.00 k 0.00000 in Reactions ... @Left 36.78 k @Righi 36.78 k at 60.12 ft at 0.00 ft at 0.00 ft , m KLT CONSULTING STRUCTURAL ENGINEERS 3430'1RVINE AVENUE NEWPORT B'EACH, CA 92660 949-263:-1~08 949-263-1310 (FAX) E-MAI!-: KLTNB@AO!-,COM Description NEW STEEL BEAM AT NEW OPENING Title: Dsgnr: Description : Scope: Job# Date: 2:18PM, 20 SEP 01 General lnfonnation Calculatic>ns are designed to AISC 9th Edition ASD and 1997 USC Requirements Steel Section : W16X26 Center Span Left Cant. Right Cant Lu : Unbraced Length I Distributed Loads · DL LL ST Start Location End Location S1,1mmary #1 0,085 0.128 20.00 ft 0.00 ft 0.00 ft 20.00 ft #2 Pinned-Pinned Bm Wt. Added to Loads LL & ST Act Together #3 #4 Using: W16X26 section, Span = 20.00ft, Fy = 36.0k~i f.:nd Fixity= Pinned-Pinned, Lu = 20.00ft, LDF = 1.000 Moment fb : Bending Stress fb/Fb Shear fv : Shear Stress fv/Fv I .Force & Stress Summary Actual 11.954 k-ft 3.739 ksl 0,618 : 1 2.391 k 0.610 ksl 0.042: 1 Allowable 19.334 k-ft 6.047 ksi 56.484 k 14.400 ksi #5 Fy Load Duration Factor Elastic Modulus #6 36.00ksi 1.00 29,000.0 ksi . #7 k/ft k/ft k/ft ft ft Beam OK Static Load Case Governs Stress Max. Deflection Length/DL Defl Length/(DL+LL Defl) -0.099 in 5,238.7: 1 2,434.0: 1 «-These columns .:ire Dead + Live Load placed as noted -» DL LL LL+ST LL LL+ST Maximum ~ G Q~a~r @Q,mt~c @Ci!!l1§ @Qaats Max.M+ 11.95 k-ft 5.55 11.95 k-ft Max.M-k-ft Max. !\1@Left k-ft Max. M @ Right k-ft Shear@ Left 2.39k 1.11 2.39 k Shear @ Right 2.39k 1.11 2.39 k Center Defl. -0.099 In -0.046 -0.099 -0.099 0.000 0.000 in Left Cant Oefl 0.OOOin 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in o.boo 0.000 0.000 0.000 0.000 in ... QueryDefl@ 0.000 ft 0.000 0.000 0.000 0.000 0.000 In Reaction @ Left 2.~9 1.11 2.39 2.39 k Reaction@Rt 2.39 1.11 2.39 2.39 k Fa calc'd per 1.&-2, K*Ur > Cc I Secti.on · Properties W16X26 Depth 15.6901n Weight 26.09 #/ft r-JOC 6.260 in Width 5.5001n I-xx 301.00 ln4 r-yy 1.117 In Web Thick 0.2501n 1-yy 9.59 in4 Rt 1.360 In Fiange Thickness 0.3451n s-xx 38.368 ln3 Area 7.681n2 s-yy 3.487 in3 u I KLT CONSULTING STRUCTURAL ENGINEERS 3430 IRVINE AVENUE NEWPORT BEACH, CA 92660 949-263-1308 949-263-1310 (FAX) E-MAIL: K~ TNB@AOL.COM Title: Dsgnr: Description : Scope: Rov: .110300 u1er.xw-0~,,.v.,,.u.u-1ua-1m.-Steel Beam Des·1gn (c) 1983-99 BNBRCALC Description NEW STEEL BEAM AT NEW OPENING I Sketch & Diagram o.4w;mm n In I I mm II Im 111 mmn1 mm O.lllk/A 11-----~20A __ l Rmax • 2,)9111: 'lmx01d•2.)9111: Mmlx•12.0ll:·A Dax• .o.o- Job# Date: 2:18PM, 20 SEP 01 KLT CONSULTING STRUCTURAL ENGINEERS 3430 IRVINE AVENUE NEWPORT BEACH, CA 92660 949-~63-1308 949-263-1310 (FAX) 1:-MAiL: KLTNB@AOL.COM Title: Dsgnr: Description : Scope: Job# Date: 1 :56PM, 21 SEP 01 0\ ~: 510300 uaer:-KW,o~..cm, ver.s.1.,.22.r ... 1m,Wla31 General Timber Beam (c) 1983-99 BNBRCALC Page f Description STAIR STRINGER DESIGN General Information Calculations are designed to 1997 NOS and 1997 UBC Requirements Section Name Beam Width Beam Depth Member Type 2x14 ~~ Z.,<li.J; 1.5001n 13.2501n Bm Wt. Added to Loads Load Dur. Factor Center Span .Left Cantilever Right Cantilever Dougias Fir -Larch, No.1 Fb Base Allow FvAllow 10.00ft ..... Lu ft ..... Lu ft ..... Lu 1,000.0psl 10.00 ft 0.00 ft 0.00 ft Beam End Fixity 1.000 Pin-Pin 30.oobpcf FcAllow 95.0psi 625.0psi 1,700.0ksl Repetitive Member Wood Density I Full Lengh Uniform Loads Center DL Left Cantilever DL Right Cantilever DL Summary E I LL LL LL I Span= 10.00ft, Beam Width-= 1.5001n x Depth = 13.251n, Ends are Pin-Pin Max Stress Ratio o.921 : 1 Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. Mallow -fb 641.96 psi Fb 697.16 psi Deflections Center Span ... · Deflection ... Location ... Length/Def! I Stress Cales · Bending Analysis Ck 33.438 Le Cf · 1.000 Rb @.Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction ! Query Values 2.35k-ft 0.OOk-ft 0.00 0;00 2.55 fv Fv Dead Load -0.009 in 5.000ft 12,650.4 k-ft k-ft 19.505 ft 37.133 Max Moment 2.35 k~ft 0.00 k-ft 0.00 k-ft @ Left Support 1.41 k 14.830 ln2 95.00 psi 0.94 k 0.94 k 2.3 k-ft 2.5 k-ft Maximum Shear* 1.5 Allowable at 5:000 ft 6.000 ft Sflear: @Left @Right at Camber: @Left @Center @Right 70.88 psi 95.00 psi Total Load -0.085 In 5.000 ft 1,403.55 Reactions ... Left DL Right DL 0.10 k 0.10 k Left Cantilever ... Deflection ... Length/Def! Right Cantilever ... Deflection ... Length/Def!_ Max Max Dead load 0.000 In 0.0 0.000 In 0.0 Sxx 43.891 in3 Area 19.875 ln2 Cl 0.606 sxx Reg'd 40.42 ln3 0.00 in3 0.OO-ln3 @ Right Support 1.41 k 14.830 ln2 95.00 psi Bearing Length Req'd Bearing Length Req'd Allowable fb 697.16 psi 1,150.00 psi 1, 150.00 psi 1.002 in 1.002 In M, V, & D @Specified Locations @ Center Span Location = 0.00 ft 0.00 ft . 0.00 ft Moment 0.OOk-ft 0.OOk-ft 0.OOk-ft Shear 0.94 k 0.00 k 0.00 k @ Right Cant. Location = @ Left Cant. Location = Beam Design OK 1.4 k 1.9 k 0.94 k 0.94k 0.000 In 0.014 in 0.000 In 0.94 k 0.94k Total Load 0.000 In 0.0 0.000 in 0.0 Deflection 0.0000 In 0.0000 In 0.0000 in KLT CONSULTING STRUCTURAL ENGINEERS 3430 IRViNE AVENUE NEWPORT BEACH, CA 92660 949-263.,1308 949-263-1310 (FAX) E-MAIL: KLTNB@AOL.COM Title: Dsgnr: Description : Scope: Rev: $10:100 Uacr.KW-0604033, Vct$.l.,,2l--1 .... Jm, Win3l General Timber Beam (<)'1983-99 BNBRCALC Description STAIR STRINGER DESIGN I SJ<~tch & Diagram 1si-vwmnmim111nni1nmmmnmm 1"~111• Rmlx•0.91: VWMOlell•Q.9k / Job# Date: 1 :56PM, 21 SEP 01 KL T CONSULTING STRUCTURAL ENGINEERS 3430 IRVINE AVENUE Title: Dsgnr: Job# Date: 2:53PM, 21 SEP 01 NEWPdRT BEACH, CA 92660 Description : 949-263-1308 949-263-1310 (FAx) E-MAIL: KLTNB@AOL.COM Scope: Rov: '10300 . U,cr.·KW-0~4033, Vcr5,l.,,11""'1-1999,Wlll31 General Timber Beam (c) 1983-99 IIN'BRCALC Page .Y Description STAIR STRINGER SUPPORT BEAM AT INTERMEDIATE LANDING General Information Calculations are designed to 1997 NDS and 1997 USC Requirements Section Name 4x10 Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density I PQint Lqads 3.5001n 9.2501n Sawn 1.000 Pin-Pin 30.000pcf 900:0lbs lbs Center Span 5.00ft ..... Lu 1.67 ft Left Cantilever ft ..... Lu 0.00 ft Right Cantilever ft ..... Lu 0.00 ft Dquglas Flr -Larch, No.1 Fb Base Allow 1,00Q.0psl FvAllow 95.0psl FcAllow 625.0psl E 1,700.0ksi 900.0lbs 900.0lbs lbs lbs lbs lbs lbs lbs lbs lbs Dead Load Live Load ... distance 900.0lbs lbs 0.OOO·ft 1.670 ft 3.340ft 5.000ft 0.000 ft 0.000 ft 0.000ft m summary I Span= 5;00ft, Beam Width = 3.5001n x Depth = 9.251n, Ends are Pin-Pin Max Stress Ratio o.448 : 1 Maximum Moment 1.5 k-ft Allowable 5.o k-ft Maximum Shear* 1.5 Allowable Max. Positive Moment Max. Negative Moment Max-@ Left Support Max @ Right Support Max.Mallow fb 365.40 psi Fb 1, 196.84 psi I Deflections Center Span ... Deflection ... Location ... Length/Deft I Stress Cales Bending Analysis Ck 33.438 Le Cf 1.200 Rb @Center @ Left Support @ Right Support Shear Analysis .Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction I Query Values 1.52k.ft at 2.240 ft 5.000 ft Shear: @Left @Right 0.OOk-ft at 0.00 k0ft Camber: @Left @Center @Right 0.00 k-ft 4.98 fv 42.56 psi Fv 95.00 psi Dead Load -0.018 In 2,500ft 3,368.4 Total Load -0.018 In 2.500 ft 3,368.41. Reactions ... Left DL Rlgt,t DL 1.82 k 1.82 k Left Cantilever ... Deflection ... Length/Deft Right Cantilever ... Deflection ••• Length/Def! Max Max Dead Load 0.000 in 0.0 0.000 In 0.0 3.439 ft 5.583 sxx 49.911 ln3 Area 32.375 ln2 Max Moment 1.52 k-ft 0.00 k-ft 0.00 k-ft @ Left Support 1.~7 k 14.448 ln2 95.00 psi 1.82 k 1.82 k Cl 0:997 SxxReg'd 15.24 in3 o.oo ln3 0.00 in3 @ Right Support . 1.38 k 14.505 ln2 95.00 psi Bearing Length Req'd Bearing Length Req'd Allowablefb 1, 196.84 psi 1,200.00 psi 1,200.00 psi 0.830 in 0.831 In M, V, & D @Specified Locations @ Center Span Location = 0.00 ft 0.00 ft 0.00 ft . Moment 0.OOk-ft 0.OOk-ft 0.OOk-ft Shear 0.92 k 0.00 k 0.00 k @ Right Cant. Location = @ Left Cant. Location = Beam Design OK 1.4k 3.1 k 0.92 k 0.92k 0.000 in 0.027 In 0.000 In 1.82 k 1.82k Total Load 0.000 in 0.0 0.000 in 0.0 Deflection 0.0000 In 0.0000 In 0.0000 In e KLT CONSULTING STRUCTURAL ENGINEERS 3430 IRVINE AVENUE NEWPO.RT BEACH, CA 92660 949-263-1308 949-263-1310 (FAX) E-~AIL: KLTNB@AOL.COM Title: Dsgnr: Description : Scope: bv: .!10300 UICl: KW.Ot!:><403', Ver .1.1.,. 22-11111-Jm, 'W!o3l (c) 198:1-99 BNBRCALC General Timber Beam Job# Date: 2:53PM, 21 SEP 01 Page .Z Description STAIR STRINGER SUPPORT BEAM AT INTERMEDIATE LANDING 09/09/2002 YINON HAAZIIAI 4241 JUTLAND DR, #304 SAN DIEGO CA 92117 Re: Application Dc;1te: 11/26/2001 Plan. Check#: PCR01305 Address: 2091 RUTHERFORD RD Expiration Date: 11/26/2002 Permit Type: PLAN CHECK REVISION Description: SPEC SUITE ADD HVAC TO EXISTING IMPROVEMENT You applied to have your plans checked on the date noted above. To date, the related building permit has not been obtained. The original plan review application will expire as no building permit has been issued. Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed. The provisions of sections 304 (d) of the Uniform Building Code state: "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to . renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department. __ Project Abandoned -I will pick up plans within 10 days _____ Project Abandoned -Plans may be destroyed. If you have any questions, please contact the Building Department at (760) 602-2718. Raenette Abbey Building Department PERMIT APPLICATION FOR OFFICE USE ONLY PLAN CHECK No.6* EST. VAL. CITY <£>F CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck. Deposit ________ _ Validated By __ --+---.------ Date __ ---\1,4\:-1l,--'2 .... ,11;J-+(..,..u:+-( __ _ Address (include Bldg/Suite #) -Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel # Existing. Use Proposed Use # of Bathrooms Name ~ ;-;;.:l?BP~l=~~:9.wiitiL , . ~ ... , Address ""·::-'" .. -.--\":;.>~ Name Address 1,Q£E,~of.!r~"l!f<fR1l.¢'.(JJ,;J?~6!x1.t:JAM~~2~-- City City. State/Zip Telephone# -.. , .. .: S.tate/Zip Telephone# -'{~-: ·(sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed ~tatement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). Name Address City State/Zip Telephone# State License # _________ _ License Class--~-------City Business License # _______ _ Designer Name Address City State/Zip Telephone State License # _________ _ (q;.[c..·$9Ji1{~1tf,~Q9ll!'l.fJ:t,t.~AJfc;>ff'),', ·"" .,. · ... _-: :::, ', _:_ ,,. ,: .. :.~ :::~:.:::::;;:·:· ... -:-;_T,:-·.:;;,::1/7~:::~,-:::z::: ;-~'.}~"'.;':.7-iU:;::~::-;"?~:;;:·:::.~.~ sTE·';. Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued; 0 I have and will maintain workers' compensation, as .required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation-insurance carrier and policy number are: Insurance Company____________________ Policy No.____________ Expiration Date _______ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED D.OLLARS [$1001 OR LESS) 0 -CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers'' Compensation.Laws of California. WARN.ING: Faih.,1re to secure workers' compensation coverage is 1,mlawful, 9:nd shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE. ____________________________ DATE ________ _ t?:~':-;;p,w~l;R~~Qjii_pi;R:'ct;C~IJA-TiP.t(': ;:. -.. , :.> :':::':::·.-~:·;_[:.:::~':t<:::::i~c'.'i'.:~.· :·, )~S'fi,::;·,;_'._',._:;,,_~-:.'.~·,\:''ib~ . .:'.,,. I.hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Prof11ssions Code: The Contractor's License l.:aw does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will-have the burden of proving that he did not build or improve for the purpose of sale); 0 I, as owner of the property, am exclusively contracting with lic'ensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law dges not apply to an owner of property who builds .or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to tlie Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. !·personally plan· to provide the major labor and materials for construction of the·proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for tne proposed work. 3. I have contracted _with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license.number): _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ________________________ -'-------'--------~------------------ PROPERTY OWNER SIGNATURE ___________ --'----------DATE ________ _ 1Q,,GMR1=irtt.i:i1$~!:Qt!:PtJ1.rfi:>Jt'tf.itiJ?rf1;$iti.it!ff~'!.:~utt@JNl:fe.al\t1tt~S~~\1.Y:i!.:;z;?~·t1~J\'.~;} ;'.':'.::,:f:·<-::'t:t('{/~~:J··:::1!TI::.-fI".::1:. Is the applicant or future building occupant required to submit a business plan, acut.ely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the. applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the f~cility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF-OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. i~i,J:.~'9.N~T~ife:T:TQ~l\.EJ\0?,!NG,~]EN~Y~ :. ~,·,.-· I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ____ ~~-------- (E!X:.~ ~~RJ;!.C~ll"f·~l;:~Tlfl~A;Tl.Qfll .. :~ . , "::::: , ;·.:; .. ·. '.; . :., ! certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep an!l demolition or const~uction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such p_ermit is not commenced within 180 ga: s from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commen e a peri i(J6'o d ys (Section 106.4.4 Uniform Building Code). '-· -I!-7 Et" ~o I APPLICANT'S SIGNATURE _..,,..,,:::;.::c.__;c._~.c,....q:__________________ DATE .,,_, YELLOW: Applicant PINK: Finance EsGil Corporation 'l:n. Partners/i.ip wit/i. qovemment for 'BuiUing Safetg DATE: 12/5/2001 ~NT JURISDICTION: Carlsbad ~EVIEWER D FILE PLAN CHECK NO.: 01-3138 REVl/PCR 01-305 ~----SET: I PROJECT ADDRESS: 2091 Rutherford Road PROJECT NAME: Mechanical for spec suite C CNI...L-SbA..D Tf C{-f1'J I CA l-c"H?-:) D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The-plc;rns transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [ZI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [ZI The applicant's copy of the check list has been sent to.: Yihon Baqzilai 4241 Jutland Drive Suite 304 SD 92117 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [ZI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: FA y:: #: 858 27 4-5717 Date contacted: 12-1 i5 lo, (by: \C4--) PHO/\JE-#: 866-5622 Mail .., Telephone../ Fax In Person D· REMARKS: By: Eric Jensen Esgil Corporation D GA D MB D EJ D PC Enclosures: 11/27/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 01-3138 REVl/PCR 01-305 12/5/2001 GENERAL PLAN CORRECTI.ON LIST JURISDICTION: Carlsbad REVl/PCR 01-305 PROJECT ADDRESS: 2091 Rutherford Road DATE PLAN RECEIVED BY ESGIL CORPORATION: 11/27/01 REVIEWED BY: Eric Jensen FOREWORD (PLEASE READ): PLAN CHECK NO.: 01-3138 DATE REVIEW COMPLETED: 12/5/2001 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations-enforced by the Building Department. You may have other corrections based on laws· and ordinances enforced by the Planning Department, Engineering Department or other departments. · The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the original tracings and submit two new complete sets of prints to: ESGIL CORPORATION. • ro facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes D No MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Eric Jensen 1 . The licensed designer must sign the approved set of the plans. 2. No plumbing or electrical design has been included with this set for plan check. Carlsbad 01-3138 REVl/PCR 01-305 12/~/2001 ENERGY CONSERVATION 3. Revise the energy calculations to be based upon the total conditioned floor area, mezzanine and first floor. There is no separation between the two. •!• Note: If a separation wall is included, please revise the floor area on the first floor to accurately reflect the floor area. 4. Is the mechanical equipment supplied adequately sized for both the mezzanine and the main floor areas? •!• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Eric Jen~en at Esgil Corporation. Thank you. Carlshad 01-3138 REVl/PCR 01-305 12/5/2001 .. VALUATION. AND PLAN CHECK FEE JURISDICTION: Carlsbad REVl/PCR 01-305 PLAN CHECK NO.: 01-3138 PREPARED BY: ~ric J·ensen DATE: 12/5/2001 BUILDING ADDRESS: 2091 Rutherford Road BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning_ Fire Sprinklers · TOTAL VALUE Jurisdiction Code cb By Ordinance - Bldg. Permit Fee by Ordinance ! • J Plan Check Fee by Ordinance Type of Review: D Complete Review D Structural Only D Repetitive Fee =8 Repeats * Based, on hourly rate D Other 0 Hourly 1 j Hour* Esgil Plan Review Fee Comments: 1 hour mechanical plan check. ($) $120.ool $96.001 Sheet 1 of 1 macvalue.doc