Loading...
HomeMy WebLinkAbout2100 COSTA DEL MAR RD; ; CB130896; Permit06-05-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB130896 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2100 COSTA DEL MAR RD CBAD Tl Sub Type COMM 2165900100 Lot# 0 $6,800 00 Construction Type NEW Reference # Status Applied Entered By Plan Approved Issued Inspect Area Plan Check # ISSUED 04/05/2013 LSM 06/05/2013 06/05/2013 LEGENDS REST-BUILD NEW 7' MASONRY FIREPLACE/ INSTALL A PRE=FAB INDOOR/OUTDOOR FIREPLACE AT EXTERIOR OF BUILDING WALL/DEMOLISH 3300 SF EXTERIOR CONCRETE PATIO AND REPLACE Applicant CHRIS MARESCA Owner L C INVESTMENT 2010 INC 2206 ALBATROSS ST SAN DIEGO CA 92101 619-238-0661 1601 ELM ST DALLAS TX 75201 Building Permit $97 47 Meter Size Add'l Building Permit Fee $0 00 Add'l Red Water Con Fee $0 00 Plan Check $68 23 Meter Fee $0 00 Add'l Building Permit Fee $100 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $1 43 PFF (3105540) $0 00 Park Fee $0 00 PFF (4305540) $0 00 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $38 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $41 00 Other Building Fee $0 00 MECHANICAL TOTAL $0 00 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Reel Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SBl 473) Fee $1 00 HMP Fee 99 Fire Expedidted Plan Review $0 00 Green Bldg Standards Plan Chk 99 TOTAL PERMIT FEES $347 13 Total Fees $347 13 Total Payments To Date $347 13 Balance Due $0 00 Inspector FINAL APPROVAL Date /^ "^O • / 3 Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Secfion 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othero/ise expired 06-05-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No SWI 30180 Job Address Permit Type Parcel No Reference # CB# Project Title Pnority Applicant DENNIS KINSLEY 2100 COSTA DEL MAR RD CARLSBAD CA 92009 760-930-7075 Emergency Contact DENNIS KINSLEY 2100 COSTA DEL MAR RD CBAD SWPPP 2165900100 Lot# 0 CB130896 LEGENDS REST- DEMO AND REPLACE 3300 SF EXTERIOR CONCRETE/ADD PATIO AND L Status Applied Entered By Issued Inspect Area Tier Owner L C INVESTMENT 2010 INC 1601 ELM ST DALLAS TX 75201 ISSUED 05/14/2013 LSM 06/05/2013 1 760-809-5230 SWPPP Plan Check SWPPP Inspections Additional Fees $47 00 $56 00 $0 00 TOTAL PERMIT FEES $103 00 Total Fees $103 00 Total Payments To Date $103 00 Balance Due. $0 00 FINAL APPROVAL SIGNATURE /vXT "^PLANNING [^ENGINEERING g^UILDING ^ THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE FIRE (•HEALTH •HAZMAT/APCD ^ CITY OF CARLSBAD Building Perinit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www carlsbadca gov Plan Check tio.(ll^[^^^ Est. Value Plan Ck. Deposit /-CO Date SWPPP JOB AODRESS 2100 Costa Del Mar Road, Carlsbad, CA 92009 # OF UNITS I fl BEDROOMS SUITEt/SPACEt/UNrr* 216 123 03 05 CT/PROJtCT # # BATHROOMS TENANT BUSINESS NAME Legends Restaurant CONSTR TYPE lll-A occ GROUP A-2 OESCRIPnON OF WORK Inc/ude Square Feot of Affected Area(s) • DEMOLISH 3,286 SF EXTERIOR CONCRETE PATIO AND REPLACE WITH NEW CONCRETE PATIO AND (1) FIREPUCE - INSTALL A PRE-FABRICATED INDOOR/OUTDOOR FIREPLACE AT EXTERIOR BUILDING WALL EXISTING USE Restaurant PROPOSED USE Restaurant GARAGE (SF) PATIOS (SF) 3,286 DECKS (SF) FIREPLACE VES[7]# ' N0| I AIR CONDrriONING YEsf/lNol I FIRE SPRINKLERS YES[7]NO[~] APPUCANT NAME (Primary Contact) Dennis Kinsley APPUCANTNAME (Secondary Contact^ Chris Maresca ADDRESS 2100 Costa Del Mar Road ADI 2206 Albatross SL CITY Carlsbad STATE CA ZIP 92009 San Dieqo STATE CA ZIP 92101 PHONE 760-930-7075 FAX 760-931-7557 PHONE 619-238-0661 FAX 619-238-0695 EMAII dkinsley@lacosta.com EMAIL cmaresca@skindesignstudio.com PROPERTY OWNER NAME LC :P<IC: COI Crgg BU&^AME I N/A ADDRESS ADDRESS , H . di^^9/llnro fk crrv CM 5 pifl-g STATE ZIP ZIP PHONE FAX PHONE INE FAX EMAIL ARCH/DESIGNER NAME & ADDRESS S.K.I.N. inc. San Dieao. CA 92101 C-32449 SmTEVC CITY BUS UC # (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant forsuch permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Cnapter g. commendingwith Section 7000 of Division 3 of the Business and Professions Code) or that he Is exempi therefrom, and the basis for the alleged exemption Any violation of Section 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than Five hundred dollars ($500)) Workers' CompenBatlon Declaration / hereby affirm under penally of perjury one of Ihe following declarations BI have ond will maintain a certificate of consent to self insure fa woikers' compensalion as provided by Sedion 370O of Ihe Labor Code for Ihe performance of Ihe work for which Ihis peimit is issued I have and will maintain workerslxompensatlon as required bv Seclion 3700 ol the Labor Code la Ihe perlomiance of Ihe wok fa which Ihis oeimil is issued My workers compensalico insurarce earner and policy numberare InsuranceCo yV^A JT^^f l\J^ This seclion need no( be completed if Ihe p^il is fa one hundred dollars (SI OO) a less PdicyNo OQShfX Expiralion Dale /fa IMS [/] Certificate of Exemption I certify lhat in lha performance of Ihe work (or which Ihis permil is issued I shall nol employ any peison in any manner so as to become subject to the Workers ComperBalion Laws of Califania WARNING Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensatlan, damageMis provided for In Section 3706 of the Labor code. Interest and attorney's fees CONTRACTOR SIGNATURE UC n'^^ [g<5ENT DATE ^ ® ©' a @ e?»o OD D ft © 15 0 ® 8 g a Z3 m a TSV® m i hereby affirm thai I am exempt from Contractor's bcense Law for l/ie follomng reason I I I, as ownei ol Ihe property a my employees wilh wages as lhai sole compensation will cto the wak and the slixlure is nol intended or olfeted for sate (Sec 7044, Business and Professions Code The Conliaclot s License Law does nol apply lo an owner of prcpeily who builds or improves Ihereon, and who does such work himself or through his own employees, provided lhal sxh improvements are nol inlended a offeied fa sale II however Ihe bmldng or imprcvemeni is sold within ons year of complelion Ihe ownei-builder will have Ihe burden of proving lhal he did nol build oi impiove fa Ihe purpose of sale) [7] I as owner ol Ihe pioperty, am exclusively conlracting with licensed contraclas lo construct the protect (Sec 7044 Business and Professions Co* The Conlractoi's License Law (toes nol apply to an owner of picperty who builds a imprcwes Iheieon and contracts foi such pioiects with conlractoi{s) licensed puisuant lo the Contracta s License Law) • I am GKempt under Seciion _ _BiBiness and Professions Code (or this reason 1 I peisonally plan to piovide the majOi laboi and matenals fa construction of the pioposed pioperty impiovemenl Qves | j^o 2 1 (have / have nol) sgned an application foi a buildng pemnil for Ihe prcposed woik 3 I have conlracled with Ihe following person (firm) lo picwde Ihe proposed constiuction (include name addiess / phona / contraclas license number) 4 I plan lo provide pations of Ihe woik, bul I have hiied Ihe Idlowing person lo coadnale supervise and provide Ihe maia woik (include name / address / phone / contraclas license nimber) 5 I will provide some of Ihe work bul I have conlracled (hired) Ihe follcwing peisons lo piovide Ihe woik incicaled (include name / address / phone / lype of work) jgfpROPERTY OWNER SIGNATURE QAGENT DATE '{2®C3Pa@Q'S tPGOOS S@(S170®ffl (?®0 Gg®G9°G@$f1®SG3'i?l}^(l •{3}0a®0CI@ (7£il3(230T?S ®G5.a?? Is Ihe ^icant a future buildi^ oatpart requred lo sutmil a business plan, acutely hazaidous mateiids re^slralion fam or nsk management and prevention program under Sections ^605 25633 a 25534 of the Presley-Tanner Hazardous Subslance Account AcP Yes /No Is Ihe applicant a future buildng occupant required to oblain a permit fron Ihe aiipdlutionconlioldslricl a air qualily mana^ Yes / No Is Ihe facility lo be constructed svithin 1,000 feet of the outer boundary of a school site? Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EHERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I heiBby affimi that there is a construction lending agency for Bie performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name N/A Lender's Address I oeiti^ that I have leadthe application and state thatthe above Information Isconectand diat die Infaniation on the plans is accurate lagree to comply uflfi all Qtyonfuancesand Stats laHs relating to buildng constnjdion 1 hereby authorize fg>resentative of the City d Cartsbad ta enter ipon Uie above mentjoned property for inspection puiposes I /MSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABIUTIES, JUDGMEI^S, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CflY IN CONSEQUBJCE OF THE GRANTING OFTHS PERMIT OSH A An OSHA pemit B reqiaed for excaiBtions over S'O'deep and derrofiion a cotistiwtion of stru^^ EXPIRATION Every permit issued by the Building Cffictal under the provisions ofthis Code shall e<prB by 6m 180 days from the date of such peniiit or iptie buldiig a vi«Dri( auttioic^ yg^APPUCANrS SIGNATURE ,|-JA~^ —DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email bUlldinq(a>car1sbadca qov or Mail the completed form to City of Carfsbad, Building Division 1635 Faraday Avenue, Carisbad, Califomia 92008 C0#: (Office Use Only) CONTACT NAIVIE OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE Carlsbad ZIP CA PHONE FAX EMAIL OCCUPANT'S BUS LIC No DEUVERY OPTIONS PICK UP CONTACT (Listed above) OCCUPANT (Listed above) CONTFIACTOR (On Pg. 1) MAILTO. CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAIL/FAX TOOTHER ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION / CHANGE OF USE / NO CONSTRUCTION APPUCANT'S SIGNATURE DATE Inspection List Permit# CB130896 Type Tl Date Inspection Item 10/25/2013 29 Final Plumbing 10/25/2013 89 Final Combo 10/25/2013 89 Final Combo COMM Inspector Act Rl Rl PD AP LEGENDS REST-BUILD NEW 7" MASONRY FIREPLACE/ INSTALL A PRE= Comments WILL GIVE YOU CARD Wednesday, October 30, 2013 Page 1 of 1 , RECORD COPY INSPECTION RECORD m INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB B CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION B FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.carlsbadca, :rov/Buildin<f AND CLICK ON "Request Inspection" DATE: 6 /M/^ IP "YES" IS CHECKED BELpW THAT DiVISIOIVl'S APPROVAL IS REpUIRED PRIOR TO REQUESTING A FlIMAL BUILDING INSPECTION. IF YOU HAVE ANY QUEST|6NS PLEASE CALL THE APPUCABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER AUL REQUIRED APPROVALiS ARE SIGNED OFF- FAX TO 760-602-8560. EMAIL TO ••: BLD6INSPECTIONS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE.. CARLSBAD, CA 42008. BUILDING INSPECTORS CAN BE REACHED AT 760-602-27Ci<5; BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR JNSPEbTION. CB130896 2100 COSTA DEL MAR RD LEGENDS REST-BUILD NEW 7' MASONRY FIREPLACE/ INSTALL A PRE=FAB INDOOR/OUTDOOR FIREPLACE AT EXTERIOR OF BUILDING WALL/DEMOLISH 3300 SF EXTERIOR CONCRETE PATIO AND REPLACE Tl COMM Lot# CHRIS MARESCA NO >i / YES Required Prior to Requesting Building Final If Checiced YES Date Inspector Notes V Planning/Landscape 760-944-8463 Allow 48 hours ^ CIVI&I (Engineering Inspections) 760-438-389' Call before 2 pm /V r ^ Rre Prevention 760-602-4660 Allow 48 hours Type < f Ins^pectlon Type of Inspection Date Inspector CODB # ELECTRICAL .. / Date (inspector #11 FOONDATION /, f )'? #31 • ELECTRIC UNDERGROUND DUFER #12 r^lNFORCl's STEEL #34 ROUGH i^LECTRIC M6 MASONRY P'lE GROUT #33 • ELECTRIC SERVICE • TEMPORARY • GROUT • WAU DRAINS #35 PHOTOVOLTAIC #10 TILT PANELS #39 FINAL #il POUR STRIPS coDE# MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME • FLOOR DCEIUNG #44 • DUCT & PLENUM • REF. PIPING #15 ROOFSHEATHING #43 HEAT-AIR COND SYSTEMS #13 ECT. SHEAR PANELS #49 FINAL #16 INSUUTION CODB » / COMBO INSPECTION #18 EXTERIOR UTH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR UTH & DRYWALL #82 DRYWALLEXTUTH, GASTES(17,18,23) #51 POOLEXCA/STEEL/BOND/FENCE #83 ROOFSHEATING, EXT SHEAR (13,15) #55 PREPUSTER #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL #89 FINAL OCCUPANCY (19,29,39,49) Date Inspector / #22 • SEWER & BL/CO • PL/CO \X: FIRE . . • Date Inspector #21 1 NDERSROiJND DWASTE • WTR #24 TOPOUT DWASTE DwrH /I A/S UNDERGROUND VISUAL #27 TL3& SHOWER PAN A/S UNDERGROUND HYDRO #23 • GAS TEST DGAS PIPING A/S UNDERGROUND FLUSH #25 WATER H.ATER A/S OVERHEAD VISUAL #28 SOUR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL A/S riNAL coDs# STORMVYATER % F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICETO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRinEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OFVIOUTION MEDICAL GAS PRESSURETEST #610 VERBALWARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES MO •is \ Section 5416. Health and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a constructton job site The water closet shall consist of a patented chemical type toilet (b) For the purpose of this section the term construction site shall mean the location on which actual construction of a building is m progress (c) A violation of this section shall constitute a misdemeanor All construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector DATE ADDITIONAL NOTES Carlsbad 13-0896 5/30/13 EsGil Corporation In (PartnersHip wttfi government for (BuiCdtng Safety DATE 5/30/13 • APPLICANT ja<IURIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-0896 SET IH PROJECT ADDRESS 2100 Costa Del Mar Rd. PROJECT NAME Remodel Exterior Patio of Legends Restaurant XI The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to fonA/ard to the applicant contact person I I The applicant's copy of the check list has been sent to XI EsGll Corporation staff did not advise the applicant that the plan check has been completed I I EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person • REMARKS By Chuck Mendenhall Enclosures EsGll Corporation • GA • EJ • PC E-Mail In EsGil Corporation In (PartnersHip wttfi government for (ButCding Safety DATE 5/21/13 • APPLICANT ••-^luRrs-O) JURISDICTION Carlsbad O^AN-FrEVIEWER • FILE PLAN CHECK NO 13-0896 SET II PROJECT ADDRESS 2100 Costa Del Mar Rd. PROJECT NAME Remodel Exterior Patio of Legends Restaurant I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to fonward to the applicant contact person XI The applicant's copy of the check list has been sent to SKIN Inc, Att'n Chns Maresca 2206 Albatross St, San Diego, CA 92101 • EsGll Corporation staff did not advise the applicant that the plan check has been completed IXI EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Chns Maresca Telephone # (619) 238-0661 Date contacted 3/2.z-f; (by ) Email cmaresca@skindesignstudio com Fax # (619) 238-0695 £^ Mail ^Telephone Fax-^ In Person • REMARKS By Chuck Mendenhall Enclosures EsGll Corporation • GA • EJ • PC 5/16/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0896 5/21/13 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list Submit FOUR new complete sets of plans for commercial/industnal projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete 3 Provide manufacturers specification for the proposed new umbrellas If the new umbrellas exceed 120 sq ft in area, provide structural design to show how the umbrellas resist the code required wind loads The design of the umbrellas requires a 3' X3' X2ft footing for the umbrella sleeve. Detail on the plans the footings and the installation ofthe sleeve. 4 Specify on the plans the following information for the fireplace(s) provide the manufacturers installation specifications to show that the horiz. fireplace flue is an acceptable installation. • Manufacturer's name and model number, ICC approval number, or equal • Show the height of the factory-built chimney above the roof and the honzontal clearances per listing approval Chimneys shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet CMC Section 802 5 2 1 6 Provide design calculations for the proposed 8ft high masonry structure that will form the linear flame fire feature shown in detail 8/C3 0 The design must show that the proposed structural reinforcing of the masonry can resist the code required seismic loads The design calc's were provided. The design requires 4-#4 vertical reinforcing bars in each ofthe vertical legs of the feature. Detail 7/C3.0 does not specify the 4-#4 ineach leg of the masonry fireplace feature. 9 Please include a gas pipe sizing design (isometnc or pipe layout) for all new gas loads The sizing of the gas lines must be per CPC Table 12-24 for the PE gas pipe. It appears that the proposed 2" line is undersized for the PE pipe. END OF RECHECK To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Carlsbad 13-0896 5/21/13 The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Dnve, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you EsGil Corporation In (PartnersHip witH government for (ButCding Safety DATE 4/17/13 • APPLICANT •^JURIS JURISDICTION Carlsbad PLAN REVIEWER • FILE PLAN CHECK NO 13-0896 SET I PROJECT ADDRESS 2100 Costa Del Mar Rd. PROJECT NAME Remodel Exterior Patio of Legends Restaurant I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ^ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to fonward to the applicant contact person X The applicant's copy of the check list has been sent to SKIN Inc, Att'n Chns Maresca 2206 Albatross St, San Diego, CA 92101 I I EsGll Corporation staff did not advise the applicant that the plan check has been completed IX EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Chns Maresca Telephone # (619) 238-0661 Date contacted it. (by Email cmaresca@skindesignstudio com Fax # (619) 238-0695 ^^^Ma\\ Telephone. ^Fax In Person • REMARKsO^'^ By Chuck Mendenhall Enclosures EsGll Corporation • GA • EJ • PC 4/8/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0896 4/17/13 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 13-0896 JURISDICTION Carlsbad OCCUPANCY A-2 USE Outdoor patio for restaurant TYPE OF CONSTRUCTION NA ACTUAL AREA 2500 sq ft ALLOWABLE FLOOR AREA NA STORIES NA HEIGHT NA SPRINKLERS'? NA OCCUPANT LOAD 150 REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE PLANS RECEIVED BY ESGIL CORPORATION 4/8/13 DATE INITIAL PLAN REVIEW COMPLETED 4/17/13 PLAN REVIEWER Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required pnor to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. Carlsbad 13-0896 4/17/13 Please make all corrections, as requested in the correction list Submit FOUR new complete sets of plans for commercial/industnal projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete 1 Detail 2 on sheet C1 0 shows that you intend to install new double swinging doors and bi-folding doors However, detail 2/C2 1 depicting the new fireplace shows no change to the existing doors Clarify what is intended 2 Specify the size of the new double swinging doors shown in detail 2/C1 0 Note on the plans that these new doors must be 6-0" wide and equipped with panic hardware CBC Section 1008 1 10 3 Provide manufacturers specification for the proposed new umbrellas If the new umbrellas exceed 120 sq ft in area, provide structural design to show how the umbrellas resist the code required wind loads 4 Specify on the plans the following information for the fireplace(s) a) Manufacturer's name and model number, ICC approval number, or equal b) Show the height of the factory-built chimney above the roof and the honzontal clearances per listing approval Chimneys shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet CMC Section 802 5 2 1 c) Note on the plans that approved spark arrestors shall be installed on all chimneys CBC Section 2802 1 5 Provide manufacturers specification for the proposed new linear flame feature as shown in detail 8/C3 0 6 Provide design calculations for the proposed 8ft high masonry structure that will form the linear flame fire feature shown in detail 8/C3 0 The design must show that the proposed structural reinforcing ofthe masonry can resist the code required seismic loads 7 Include in the design cal's the ability of the precast concrete lintels to span as shown and support the fully grouted masonry 8 Provide the manufacturers specification for the precast concrete lintel and specify the ICC approved fabncator number for the precast concrete product Carlsbad 13-0896 4/17/13 9 Please include a gas pipe sizing design (isometnc or pipe layout) for all new gas loads Plans show you intend to install a new gas fireplace and new linear fire feature. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 • When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion ofthe building affected, is required to complywith all ofthe requirements for new buildings, per Section 1134B 2 These requirements apply as follows a) The area of specific alteration, repair or addition must comply as "new" construction b) A pnmary entrance to the building and the primarv path of travel to the altered area, must be shown to comply with all accessibility features c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features Include on the plans path of travel from the remodeled patio to the nearest rest rooms serving the patio area. The path of travel and rest rooms must be show to comply with the current disabled access standards as follows: 10 Clearly show that the site plan access from the patio to the rest rooms, per Section 1127B 1 Where necessary to provide access, shall incorporate pedestnan ramps, curb ramps, stairways and handrails, etc • DOORS 11 Show or note that doors within the path of travel from the patio to the rest rooms have hand- activated door opening hardware meets the following requirements, per Section 1133B 2 5 2 a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requinng the ability to grasp the opening hardware b) Is to be centered >30" but <44" above floor 12 Show or note that the maximum effort to operate doors shall not exceed S-Yi pounds for extenor doors and 5 pounds for intenor doors, with such pull or push effort being applied at nght angles to hinged doors and at the center plane of sliding or folding doors When fire doors are utilized, the maximum effort to operate the door may be increased to not exceed 15 pounds Section 1133B25 SANITARY FACILITIES 13 Show that passageways leading to sanitary facilities have required clear access widths, per Section 1115B 5 Show that all doonways have a) >32" clear opening b) A clear area Carlsbad 13-0896 4/17/13 i) >60" in the direction of the door swing ll) >44" away from the direction of door swing c) All stnke edge clearance dimensions are required to be met (i e 18" stnke edge distance) 14 Note that the doonways leading to sanitary facilities shall be identified, per Section 1115B 6, as follows a) An equilateral tnangle V^' thick with edges 12" long and a vortex pointing upward at men's rest rooms b) A circle thick, 12" in diameter at women's rest rooms c) A 12" diameter circle with a tnangle supenmposed on the circle and within the 12" diameter at unisex rest rooms d) The required symbols shall be centered on the door at a height of 60" e) Braille signage shall also be located on the wall adjacent to the latch outside of the doonways leading to the sanitary facilities, per Section 1117B 5 1 Carlsbad 13-0896 4/17/13 59" MIN AT FLOOR-MOUNTED WC WHEN DOOR SWINGS IN 56" MIN AT WALL-MOUNTED WC WHEN DOOR SWINGS IN 54" MIN FLUSH i- ACnVATOR ON WIDE SiDE 15 Show that the accessible rest room is to be provided with a 60" minimum diameter clear space measured from the floor to a height of 27 inches NOTE Doors (other than the door to the accessible toilet compartment) in any position may encroach into this space by not more than 12 inches, per Section 1115B 3 1 16 Doors shall not swing into the clear floor space required for any fixture withm the toilet facility Section 1115B 3 1 2 17 Show that at least one water closet fixture, located in a compartment, shall provide the following, per Section 1115B 3 1 4 Carlsbad 13-0896 4/17/13 a) >28" clear space from a fixture (or >32" clear space from a wall) at one side b) The other side of the water closet shall provide 18" from the centerline of the water closet to the wall c) The compartment shall be a minimum of 60" wide d) Clear space in front of the water closet shall be i) >48" if the compartment has an end opening door ll) >60" IS required for side opening doors e) Grab bars shall not project more than 3" into the clear spaces indicated 18 Show, or note, on the plans that the accessible water closets meet the following requirements, per Section 1115B4 1 a) The seat is to be >17" but <19" in height b) The controls for flush valves shall be i) Mounted on the side of the toilet area ll) Be <44" above the floor 19 Show, or note, on the plans that accessible unnals meet the following requirements, per Section 1115B42 a) The nm of at least one unnal shall i) Project at least 14" from the wall ll) Be <17" above the floor b) The control mechanism is to be located <44" above the floor c) >30" X 48" clear floor space is provided in front of the accessible unnal Section 1115B 4 2 20 Show that accessible lavatones comply with the following, per Sections 1115B 4 3 a) >30" X 48" clear space is provided in front for fonward approach The clear space may include knee and toe space beneath the fixture b) When lavatones are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall c) The counter top is <34" maximum above the floor d) >29" high, reducing to 27" at a point located 8" back from the front edge e) >9" high x 30" wide and 17" deep at the bottom f) Hot water pipes and dram lines are insulated 21 Show that grab bars comply with the following, per Section 1115B 4 a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment b) They shall be securely attached 33" above the floor, and parallel NOTE Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36" Carlsbad 13-0896 4/17/13 c) Grab bars at the side shall be located I) 15" to 1672" (±1") from the center line of the water closet stool II) Be >42" long with the front end positioned 24" in front of the stool III) Total length of bars at the back shall be >36" d) The diameter, or width, of the grab bar gnpping surface is >1 %" but <1 Vi\ or the shape shall provide an equivalent gnpping surface END OF CODE REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Dnve, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you Carlsbad 13-0896 4/17/13 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Chuck Mendenhall BUILDING ADDRESS 2100 Costa Del Mar Rd. PLAN CHECK NO 13-0896 DATE 4/17/13 BUILDING OCCUPANCY A-2 TYPE OF CONSTRUCTION NA BUILDING PORTION AREA ( Sq Ft) Valuation Multiplier Reg Mod VALUE ($) patio Remodel 2500 City Est Air Conditioning Fire Spnnklers TOTAL VALUE Junsdiction Code Cb By Ordinance Bldg Permit Fee by Otdinance Plan Check Fee by Ordinance Type of Revievi/ • Complete Review/ • Repetitive Fee ^ Repeats Based on hourly rate • Other a Hourly EsGil Fee n structural Only 1 5 Hrs. @* $150 00 Comments Sheet 1 of 1 macvalue doc + ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 04/11/13 PROJECT NAME: UCOSTA RESORT & SPA PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2100 COSTA DEL MARRD VALUATION: PROJECT ID: CB 13 896 APN: 216-123-03 Ihls plan checkj:evfew is complete and has been APPROVED by the ENGINEERING Division. A Final Inspection by the Division is required ; Yes I7JNO 1 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: DKINSLEY@LACOSTA.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a buiiding permit. Resubmitted plans should include corrections from all divisions. For questions or clanfications on the attached checklist please contact the following reviewer as marked. ~f£ ?v*ENJ3ilNEER!NGf 1'^IbinRE^PREf ENTIONIIT:^^ 1 1 Chris Sexton L J 760-602-4624 Chris Sexton@carlsbadca gov ' 7 j Kathleen Lawrence ——•^ 760-602-2741 Kathleen Lawrence@carlsbadca gov j 1 Greg Ryan 1 J 760-602-4663 Gregorv RvanOcarlsbadca gov j ' Gina Ruiz - ' 760-602-4675 Gma Ruiz@carlsbadca gov Linda Ontiveros • 760-602-2773 Lmda OntiverosOcarlsbadca gov r j Cindy Wong •—^ 760-602-4662 Cvnthia WongOcarlsbadca gov F j Dominic Fieri ' 760-602-4664 Dommic FieriOcarlsbadca gov Remarks: Set# Any outstanding issues will be marked with [XJ Make the nece-tsary corrections for compliance with apphcable codes and standards Submit corrected plans and/or specifications to the Buildmg division for re-submittal to the tngmeenng division Items that conform to pennit requirements are marked with'^/l 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale Show North arrow Existing & proposed structures Existing street improvements Property lines (show all dimensions) ^ J Easements / i Right-of-way width & adjacent streets <__] Dnveway widths !„_. Existing or proposed sewer lateral I. . Existing or proposed water service r I ...J Submit on signed approved plans DWG No Show on Site plan • L/J Drainage patterns [ J Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course r IJ^^^ "^^^ FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building" J Existing & proposed slopes and topography jSize, location, alignment of existing or proposed sewer and water service{s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception J Sewer and water laterals should not be located within proposed dnveways, per standards Include on title sheet 1/1 Site address r7~| Assessor's parcel number r/H Legal description/lot number _ ^ commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufactunng, warehouse, office, etc) previously approved Show all existing use of SF and new proposed use of SF Example. Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No Subdivision/Tract Reference No(s) E-36 Page 2 of 6 REV 6/01/12 Set# 1 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15 16 of the Municipal Code jlnadequate information available on site plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial) This information must be included on the plans If no grading is proposed write "NO GRADING" J Grading Permit required NOTE The qradinq permit must be issued and rough qradinq approval obtained pnor to issuance of a building permit I Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) All required documentation must be provided to your Engmeenng Construction Inspector The inspector will then provide the engmeenng counter with a release for the building permit [Vj No grading permit required i Minor Grading Permit required See attached marked-up submittal checklist for project- specific requirements 6. MISCELLANEOUS PERMITS 1 RIGHT-OF-WAY PERMIT is required to do work in city nght-of-way and/or private work " adjacent to the public nght-of-way Types of work include, but are not limited to street improvements, tree tnmming, driveway construction, tying into public storm drain, sewer and water utilities Right-of-way permit required for E-36 Page 4 of 6 REV 6/01/12 Set# 1 PROJECT IS EXEMPT FR STORM REQUIREMENTS : COMPETE :HED 5ES ^AN&RETURN 7. STORM WATER Construction Compliance /J Project Threat Assessment Form complete _2J Enclq^eo Project Threat Assessment Form incomplete [^^^^^^Reqmes Tier 1 Storm Water Pollution Prevention Plan Please complete attached form and retum (SW i3- (^D ) Requires Tier 2 Storm Water Pollution Prevention Plan Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city Post-Development (SUSMP) Compliance [ /"] Storm Water Standards Questionnaire complete Storm Water Standards Questionnaire incomplete Please make the corrections, re-sign the questionnaire and resubmit with next submittal Project IS subject to Standard Storm Water Requirements See city Standard Urban Storm Water Management Plan (SUSMP) for reference http //www carlsbadca qov/business/buildinq/Documents/EngStandsw-stds-vol4-ch2 pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways LZ] Rainwater harvesting (ram barrels or cistern) CT] Vegetated Roof Ll Bio-retentions cell/rain garden I I Pervious pavement/pavers CI] Flow-through planter/vegetated or rock dnp line l~l Vegetated swales or rock infiltration swales ni] Downspouts disconnect and discharge over landscape • Other E-36 Page 5 of 6 REV 6/01/12 STORM WATER Development Services CITY OF CARLSBAD COMPLIANCE ASSESSMENT B-24 Building Division 1635 Faraday Avenue 760-602-2719 www carlsbadca gov I am applying to the City of Carlsbad for the following type(s) of construction permit. ^ Building Permit • Right-of-Way Permit My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the ^following permit typesj' Electncal Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria'^ Wo Thi;eat Assessment Cnteria ly project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because It meets the "no threaf assessment aiterta on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level My project does not meet any of the High, Moderate or Low Threat cntena descnbed below Tier 1 - LMifTfirec QrVfj project d fireaf Assessment Criteria t does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria • Results in some soil disturbance, and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling) r/ef2 - Moderate Threat Assessment Cntena • My project does not meet any of the Significant Threat assessment Criteria descnbed below and meets one or more of the following cntena • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 1516 ofthe Carlsbad Municipal Code), or, • Project Will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more ofthe additional following cntena • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm dram inlet an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct 1 through April 30) r/er3 - Significant Tlireat Assessment Cntena • My project includes clearing, grading or other disturbances to the ground resulting m soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas and/or • My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas or, • My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contnbuting pollutants to neart)y receiving waters by way of storm water runoff or non-storm water discharge(s) / certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times dunng construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 ofthe Carisbad Municipal Code and to City Standards "The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is waffanted Project Address Assessor Parcel No <i.l OO d£>^A PCT- rnMi. tZKy, Cf\(Lu<, Ufro, cA fz^o<=j Owner/Owner's Authonzed Agent Name Title A2«^44 i-recrj" Owner/^^^^^jnzed Agent Signature Date 1 1 City ConjuffSnce jr My f Date/ CHK • NO ^( 1 i ((^ B-24 Page 1 of 1 Rev 03/09 STORM WATER Development Services Engineering Department STANDARDS Development Services Engineering Department ^ CITY OF QUESTIONNAIRE 1635 FaradayAvenue CARLSBAD E-34 760-602-2750 www carlsbadca gov INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment pnonty projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP) Initially this questionnaire must be completed by the applicant in advance of submitting for a deveiopment application (subdivision, discretionary permits and/or construction permits) The results ofthe questionnaire determine the level of stonn water standards that must be applied to a proposed development or redevelopment project Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject additional critena called 'Pnonty Development Project Requirements' Many aspects of project site design are dependent upon the stonn water standards applied to a project Applicant responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts City staff has responsibility for making the final assessment after submission ofthe development application If staff determines that the questionnaire was incorrectly filled out and is subject to more stnngent storm water standards than initially assessed by the applicant, this will result in the return of the development application as incomplete In this case, please make the changes to the questionnaire and resubmit to the City If applicants are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, they are advised to seek assistance from Land Development Engineenng staff A separate completed and signed questionnaire must be submitted for each new development application submission Only one completed and signed questionnaire is required when multiple development applications forthe same project are submitted concurrently In addition to this questionnaire, applicants for construction permits must also complete, sign and submit a Project Threat Assessment Form to address construction aspects ofthe project Please answer the questions below, follow the instructions and sign the form at the end 1 Is your project a significant redevelopment^ DEFINITION: Significant redevelopment is defined as the creation, addition or replacement of at least 5,000 square feet of impervious surface on an already existing developed site Significant redevelopment includes, but is not limited to the expansion of a building footprint, addition to or replacement of a structure, structural development including an increase in gross floor area and/or extenor construction remodeling, replacement of an impervious surface that is not part of a routine maintenance activity, and land disturbing activities related with structural or impervious surfaces Replacement of impervious surfaces includes any activity that is not part of a routine maintenance activity where impervious material(s) are removed, exposing underlying soil during construction If your project IS considered significant redevelopment, then please skip Section 1 and proceed with Section 2 If your project IS NOT considered significant redevelopment, then please proceed to Section 1 E-34 Page 1 of 3 REV 3/23/10 ^ CITY CARLSBAD O F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 FaradayAvenue 760-602-2750 www carlsbadca gov SECTIONI NEW DEVELOPMENT PRIORITY PROJECT TYPE Does you project meet one or more of the following cntena YES NO 1 Housina subdivisions of 10 or more dwellina units Examples sinqle family homes, multi-familv homes, condominium and apartments K 2 Commercial - areater than 1-acre Anv development other than heavy industrv or residential Examoles hospitals, laboratones and other medical facilities, educational institutions, recreational facilities, municipal facilities, commercial nursenes, multi-apartment buildings, car wash facilites, mini-malls and other business complexes, shopping malls, hotels, office buildings, public warehouses, automotve dealerships, airfields, and other light industnal facilities K 3 Heavv Industnal /Industrv- areater than 1 acre Examples manufacturina plants, food orocessina plants, metal working facilities, pnntmg plants, and fleet storage areas (bus, truck, etc) K 4 Automotive repair shop A facility categorized in any one of Standard Industnal Classification (SIC) codes 5013, 5014, 5541, 7532-7534, and 7536-7539 K 5 Restaurants Anv facility that sells prepared foods and dnnks for consumption, includina stationarv lunch counters and refreshment stands selling prepared foods and dnnks for immediate consumption (SIC code 5812), where the land area for development is greater than 5,000 square feet Restaurants where land development is less than 5,000 square feet shall meet all SUSMP requirements except for structural treatment BMP and numenc sizing cntena requirements and hydromodification requirements X 6 Hillside development Any development that creates 5,000 square feet of impervious surface and is located in an area with known erosive soil conditons, where the development will grade on any natural slope that is twenty-five percent (25%) or greater K 7 Environmentallv Sensitive Area (ESA)^ All development located within or directly adiacent^ to or discharaina directly^ to an ESA (where discharges from the development or redevelopment will enter receiving waters within the ESA), which either creates 2,500 square feet of impervious surface on a proposed project site or increases the area of imperviousness of a proposed project site to 10% or more of its naturally occurnng condition k 8 Parkina lot Area of 5.000 sauare feet or more, or with 15 or more oarkina spaces, and potentially exoosed to urban runoff x 9 Sfreefs. roads, hiahwavs. and freewavs Anv oaved surface that is 5.000 sauare feet or areater used for the transportation of automobiles, tmcks, motorcycles, and other vehicles 10 Retail Gasoline Outlets Sen/ina more than 100 vehicles oer dav and areater than 5.000 sauare feet 11 Coastal Development Zone Anv oroiect located within 200 feet of the Pacific Ocean and (1) creates more than 2500 square feet of impermeable surface or (2) increases impermeable surface on property by more than 10% K 12 More than 1-acre of disturbance Proiect results in the disturbance of more than 1-acre or more of land and is considered a Pollutant-generating Development Project" X 1 Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies, areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments), water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basm (1994) and amendments), areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego, and any other equivalent environmentally sensitive areas which have been identified by the Copermittees 2 "Directly adjacent" means situated within 200 feet of the Environmentally Sensitive Area 3 "Discharging directly to" means outflow from a drainage conveyance system that is composed entirely of flows from the subject development or redevelopment site, and not commingled with flow from adjacent lands 4 Pollutant-generating Development Projects are those projects that generate pollutants at levels greater than background levels In general, these include all projects that contnbute to an exceedance to an impaired water body or which create new impervious surfaces greater than 5000 square feet and/or introduce new landscaping areas that require routine use of fertilizers and pesticides In most cases linear pathway projects that are for infrequent vehicle use, such as emergency or maintenance access, or for pedestnan or bicycle use, are not considered Pollutant-generating Development Projects if they are built with pervious surfaces or if they sheet flow to surrounding pervious surfaces Section 1 Results If you answered YES to ANY of the questions above your project is subject to Prionty Development Project requirements Please check the "meets PRIORITY DEVELOPIVIENT PROJECT requirements" box in Section 3 A Storm Water Management Plan, prepared in accordance with City Storm Water Standards, must be submitted at time of application If you answered NO to ALL of the questions above, then your project is subject to Standard Stormwater Requirements Please check the "does not meet PDP requirements" box in Section 3 E-34 Page 2 of 3 REV 3/23/10 STORM WATER Development Services Engineering Department STANDARDS Development Services Engineering Department ^ CITY OF QUESTIONNAIRE 1635 FaradayAvenue CARLSBAD E-34 760-602-2750 WWW carlsbadca gov SECTION 2 SIGNIFICANT REDEVELOPMENT Complete the questions below regarding your redevelopment project YES NO 1 Project results in the disturbance of more than 1 -acre or more of land and is considered a Pollutant-generating Development Project (see definition in Section 1) If you answered NO, please proceed to question 2 If you answered YES, then you ARE a significant redevelopment and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below 2 Is the project redeveloping an existing pnonty project type' (Pnority projects are defined in Section 1) If you answered YES, please proceed to question 3 If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS Please check the "does not meet PDP requirements" box in Section 3 below 3 Is the project solely limited to just one of the following a Trenching and resurfacing associated with utility work"? b Resurfacing and reconfigunng existing surface parking lots'? c New sidewalk constructon, pedestnan ramps, or bike lane on public and/or pnvate existing roads' d Replacement of existing damaged pavement' If you answered NO to ALL of the questions, then proceed to question 4 If you answered YES to ANY of the questions then you ARE NOT a significant redevelopment and your project is subject to Standard Stormwater Requirements Please check the "does not meet PDP requirements" box in Section 3 below Will your redevelopment project create, replace, or add at least 5,000 square feet of impervious surfaces on an existing development or, be located within 200 feet of the Pacific Ocean and (1 )create more than 2500 square feet of impermeable surface or (2) increases impermeable surface on the property by more than 10%' If you answered YES, you ARE a significant redevelopment, and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS Please check the "does not meet PDP requirements" box in Section 3 below SECTION 3 Questionnaire Results • My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater critena per the SUSMP and must prepare a Storm Water Management Plan for submittal at time of application. My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP Applicant Information and Signature Box Address ^ ^ 2./Cto C4>STA oO-r^fifi- i^/rO, Assessor's Parcel Number(s) Applicant Name di^l^^fitzef CA Applicant Title Applicant Sioflajure Date / y E-34 Page 3 of 3 REV 3/23/10 CITY OF CARLSBAD STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP E-29 Development Services Land Development Engineering 1635 FaradayAvenue 760-602-2750 www.carlsbadca gov STORM WATER COMPUANCE CERTIFICATE / My project is not in a category of permit types exempt from the Construction SWPPP requirements My project is not located inside or within 200 feet of an environmentally sensitive area with a signrficant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s) •/ My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15 16 of the Carlsbad Municipal Code) •/ My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following cntena • located within 2CX3 feet of an environmentally sensitive area or the Pacific Ocean, and/or, • disturbed area is located on a slope with a grade at or exceeding 5 honzontal to 1 vertical, and/or • disturbed area is located along or within 30 feet of a storm dram inlet, an open drainage channel or watercourse, and/or • construction will be initiated during the rainy season or will extend into the rainy season (Oct 1 through Apnl 30) I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS 1 UNDERSTAND AND ACKNOWLEDGE THAT I MUST (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS, AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DUFJATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD OWNER(S)/OWNER'S AGEMT NAME (SIGNATURE) DATE ' STORM WATER POLLUTION PREVENTION NOTES 1 ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT 2 THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL 3 THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE 4 ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%) SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL 5 ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE 6 ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED SPECIAL NOTES PROJECT INFORIVIATION Site Address /^^Cg SAOj, 7 Z^^^ Assessor's Parcel Number ^^""^^"^^z Project ID SU^ t "SQ ( Construction Permit No Estimated Construction Start Date ^/ Project Duration. Months Emergency Contact Name jl^^AJIS^ j<^lf^S<~^ Y 24 hour Phone ']GO~9>o3 ~6t30 Perceived Threat to Storm Water Quality d Medium 0 Low If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Ort Approved By Date E-29 Page 1 of 2 REV 4/30/10 Erosion Control BMPs Sediment Control BMPs Tracking Control BMPs Non-Storm Water Management BMPs Waste Management and Matenals Pollution Control BMPs Best Management Practice (BMP) Descnption ^ Geotextiles & Mats Wood Mulching Earth Dikes and Drainage Swales Slope Drains Silt Fence Sediment Trap ' Check Dam Fiber Rolls Gravel Bag Berm Street Sweeping and Vacuuming Sandbag Barner Storm Dram Inlet Protection Stabilized Construction Ingress/Egress Stabilized Construction Roadway Water Conservation Practices Paving and Gnnding Ooerations Potable Water/lrngation Vehicle and Equipment Cleanina Matenal Delivery and Storaae Matenal Use Stockpile Management Spill Prevention and CnntrnI Solid Waste Mananempnt Hazardous Waste Mananement Concrete Waste Mananempnt CASQA Designation Construction Activity EC-7 EC-8 EC-9 EC-11 SE-1 SE-3 SE-4 SE-5 SE-6 SE-7 SE-8 SE-10 TR-1 TR-2 NS-1 NS-3 NS-7 NS-8 WM-1 WM-2 WM-3 WM-4 WM-5 WM-6 WM-8 Grading/Soil Disturbance 8 Trenching/Excavation >< X Stockpiling X, Dniling/Bonng ><^ Concrete/Asphalt Saw cutting X Concrete flatwork >< Paving K Conduit/Pipe Installation >< >< Stucco/Mortar Work >< Waste Disposal >< xl Staging/Lay Down Area X Equipment Maintenance and Fueling Hazardous Substance Use/Storaqe Dewatennq Site Access Across Dirt Other (list) Instructions Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction Add any other activity descriptions in the blank activity descnption boxes provided for that purpose and place a check in the box immediately to the left ofthe added activity descnption For each activity descrnbed, pick one or more best management practices (BMPs) from the list located along the top of the form Then place an X in the box at the place where the activity row intersects with the BMP column Do this for each activity that was checked off and for each of the selected BMPs selected from the list For Example - If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt" Then review the list for something that applies such as "Stabilized Construction Ingress/Egress" under Tracking Control Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction Ingress/Egress" column and place an X m the box where the two meet As another example say the project included a stockpile that you intend to cover with a plastic sheet Since plastic sheeting is not on the list of BMPs, then wnte m "Cover with Plastic" in the blank column under the heading Erosion Control BMPs Then place an X in the box where the "Stockpiling" row intersects the new "Cover with Plastic" column To learn more about what each BMP descnption means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropnate Best Management Practice measures The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the vanous selected BMPs to a project E-29 Page 2 of 2 REV 4/30/10 ^ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 FaradayAvenue (760) 602-4610 www carlsbadca eov DATE: 4-9-13PR0JECT NAIVIE: PROJECTID: PLAN CHECK NO: CB 13-0896 SET#: 1 ADDRESS: 2100 Costa Del Mar APN: 216-123-03-05 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed beiow. Approval from these divisions may be required prior to the issuance of a buiiding permit. Resubmitted plans should include corrections from ail divisions. [[] This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: cmaresca@skindesignstudio.com For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNIIMG 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris SextonOcarlsbadca fiov 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@cadsbadca fiov Greg Ryan 760-602-4663 Gregory RvanOcarlsbadca fiov 1 1 Gina Ruiz 760-602-4675 Gma RuizOcarlsbadca fiov 1 1 Linda Ontlveros 760-602-2773 Lmda OntiverosOcarlsbadca gov n Cindy Wong 760-602-4662 Cvnthia WongOcarlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic FieriOcarlsbadca gov Remarks: Demo patio and install 1 fireplace. COPY PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 FaradayAvenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www carlsbadca gov DATE: 04/1V2013 PROJECXF NAME: LEGENDS REST - NEW FIREPLACES PROJECT ID: CB130896 PLAN CHECK NO: 1 SET*: 1 ADDRESS: 2100 COSTA DEL MAR APN: 216-123-03-05 • This plan check review is complete and has been APPROVED by the FIRE Division. By: GR A Final Inspection by the FIRE Division is required Yes • No This plan check review is NOT COMPLETE. Items missing or Incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: ' 11*4',,, i ,/60-6C)2-2750, "" ' ^FIRE*PB EVfclON' t®,;,: • 76(&2#65: 1 1 Chris Sexton 760-602-4624 Chns SextonOcarlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen LawrenceOcarlsbadca gov X Greg Ryan 760-602-4663 Gregory RyanOcarlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma RuizOcarlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Lmda OntiverosOcarlsbadca ^ov Q Cindy Wong 760-602-4662 Cynthia WongOcarlsbadca gov • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: NONE Carlsbad Fire Departinent pyiLDING OEFL Plan Review Date of Report' Requirements Category. Tl, COMM 04-11-2013 Reviewed by Name- Address. CHRIS MARESCA 2206 ALBATROSS ST SAN DIEGO CA 92101 Permit #• CB130896 Job Name: Job Address. LEGENDS REST-BUILD NEW 7' 2100 COSTA DEL MAR RD CBAD CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW Entry 04/11/2013 ByGR Action-AP STRUCTURAL CALCULATIONS LA COSTA RESORT & SPA LEGENDS PATIO RENOVATIONS CARLSBAD, CA Prepared For: LA COSTA RESORT CO. MEC Project No.: 1323 Date Issued: 4/23/13 Revision Dates: Prepared By: """^MCNEFF ENGINEERING & CONSULTING ^ f i; f) I 1 s s I f) Is \ 1 ( n K P1) K .\ I I o 1991 VILLAGE PARK WAY SUITE 115 ENCINITAS, CA 92024 T (760) 479-9838 F (760) 479-9837 www mcneffengineering com 6 ^''^ MCNEFF ENGINEERING & CONSULTING A Pr^OFLbSION'AL CORPORMION 1991 Village Park Way Suite 115 Encinitas, CA 92024 Tel (760) 479-9838 • Fax (760)479-9837 LA CO^-TA RHFPT un H CALCULATED BY CHECKED BY DftTF RHAIF 1 ; ; i ; • i I ' 1 ! 1 ' S?' .^^Ay- ii^'U^ Tn'te ^t-A^ ' gFi2.u^-rv(eg rrp; Be •uA-i>^ (PF"! ClMii;.^ 6'Hl-'Sri^v6-r1:ro7^2ct?^ '—'~—;— ..^A-X^^ Cl^^--P^-^^^A5^^bA€_^> ^-".^ -.^'itl --A ?/'/ / y A I x-Zz_z_xr ^^^^' 3 4 •4- FT6 MCNEFF ENGINEERING & CONSULTING A PROrCSSIONAL C O R r O R A T 1 O M 1991 Village Park Way, Suite 115 Encinitas, CA 92024 Tel- (760) 479-9838 • Fax (760) 479-9837 SHEET NO . -2- CALCULATHD BY. CHECKED BY SCALE 0F_ DATE. DATE. 6- o X iS?- M' I 1 i 1 AA - 1 1 — I o/ I ' t .(9 . . • : 4: ii'lAnM'^ 0 >3.^ ^v^ MCNEFF ENGINEERING & CONS u Lll NC A PRCFESSIONAl CORPORATION 1991 Village Park Way, Suite 115 Enciritas, CA92024 Tei (760) 479-9838 • Fax- (760) 479-9837 SHEET NO . 3 CALCULATED B>. CHECKED BV SCALE DATfc. I I I t I ! I I — 1 - - ! _ 1 _ , ' , _ . I I A I L.. .j^'^A.^iX ;J 4' r- ^ |7~ I "^r^i,- ':^>.^' xfl'Uo 5)>I5D'- ^pl^'^ -A (AA^^ PVA'S'T -. T ^ - . - - S 2: m MCNEFF ENGINEERING & CONS uni NG SHEET NO . 4 A PRUFt';ilONAL rORP ORATION 1991 Village Park Way, Suite 115 Encinitas, CA 92024 Te! (760) 479-9838 • Fax (760)479-9837 CALCULATED BY_ CHECKED BY SCALE DATE. DATE. Id.- ----- |- - - -;- - T • i r - 7 , - I , '( _i__.t^ „ L-^ i _ j_.: JL AA T-Burners stainless Steel - T-Burners (#304 SS) These stainless steel t-bumers are constructed of #304SS & 1/2' tubing, drilled ports, and welded ends The gas inlet is 3' in length wiin male 1/2' pipe thread Stainless Steei T-Bumers Model # / Length TBSS24/23 5" TBSS36 / 35 5" TBSS48/47 5" TBSS60/5g 5° TBSS72/71 5" TBSS96 / 95 5° LP Kits (T-Burner, Air Mixer, & Coupler) Model # / Flame Height / BTU TBSS24LP/~10'/50k TBSS36LP /~10'/75k TBSS4BLP/-10-/100k TBSS60LP/-10''n25k TBSS72LP/-10°/150k TBSS96LP/-10'/200k 1: SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / / Business Nanre^.^^^^ f^^STT^^flM^J Business Contacts—, . Telephone # —70-75" Project Address Zjoo CffsrA pec jSoAt? City ^ State ZioCode OAi^i-S'gfirO OA f^o7 APN# Mailing Address <Uoo 0>sTA P€L/VlflriC JZJOAK? City State Zip Code Plan File# Project Contact /TJAt^-^JcA Telephone # t ) The following questions represent the facility's activities, NOT the specific project description PART I FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction pnor to plan submittal Facility's Square Footage (including proposed project) 3^Z6CP -^f^ Occupancy Rating c. 1 Explosive or Blasting Agents 5 Organic Peroxides 9 Water Reactives 13 Corrosives 2 Compressed Gases 6 Oxidizers 10 Cryogenics 14 Other Health Hazards 3 Flammable/Combustible Liquids 7 Pyrophoncs 11 Highly Toxic or Toxic Materials ^TT^None ofThesS-'a Unstable Reactives 4 Flammable Solids 8 12 Radioactives PART II SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD) If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Matenals Division, 5500 Overland Ave , Suite 110, San Diego, CA 92123 Call (858) 505-6700 pnor to the issuance of a building permit FEES ARE REQUIRED Project Completion Date i J I Expected Date of Occupancy ^ \ 1 / / Date Initials • CalARP Required Date Initials • CalARP Complete (for new construction or remodeling projects) Is your business listed on the reverse side ofthis form'' (check all that apply) Will your business dispose of Hazardous Substances or Medical Waste in any amount"? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank"? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)'' Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons'? (California's Aboveground Petroleum Storage Act) PART III SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control Distnct (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 pnorto the issuance of a building or demolition permit Note if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days pnor to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less Contact the APCD for more information YES NO 1 • m 2 • 3 • 4 • 5 • El 6 • JS 7 • El • CalARP Exempt / / Date Initials YES • NO S Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminanf? (See the APCD factsheet at http //www sdapcd org/info/facts/permits pdf. and the list of typical equipment requinng an APCD permit on the reverse side ofthis from Contact APCD if you have any questions) • • (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http //www cde ca qov/re/sd/ for public and pnvate schools or contact the appropriate school distnct) gl Has a survey been performed to determine the presence of Asbestos Containing Matenals"? H Will there be renovation that involves handling of any fnable asbestos materials, or disturbing any matenal that contains non-fnable asbestos"? ^ Will there be demolition involving the removal of a load supporting structural member? • • • Bnefly descnbe business activities Briefly descnbe proposed project 1 declare underpenalty of perjury that to the best of my knowledge and belief the responses made herein are true and correct I declare underpenalty or perjury Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION . BY FOR OFFICIAL USE ONLY DATE EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD'* APCD COUNTY-HMD APCD COUNTY-HWID APCD *A stamp in this box onlv exempts businesses from completing or updating a Hazardous Matenals Business Plan Other permitting requirements may still apply HM-9171 r02/lf) Countv of San Diego - DEH - Hazardous Matenals Division Date 1/2/ INDUSTRIAL WASTEWATER DISCHARGE PERI SCREENING SURVEY /3 Business Name street Address 'ZlOo CaSTiOt t^Gi^ M^hL Rjs>At> ^ (lAfU^<^AO <1A- J 2<fO^ Email Address PLEASE CHECK HERE IF YOUR BUSINESS IS EXEIVIPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check ail below that are present at your facility Acid Cleaning Ink Manufactunng Nutritional Supplement/ Assembly Laboratory Vitamin Manufactunng Automotive Repair Machining / Milling Painting/Finishing Battery Manufactunng Manufacturing Paint Manufactunng Biofuel Manufactunng Membrane Manufactunng Personal Care Products Biotech Laboratory (1 e water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting/Forming Pesticide Manufacturing / Car Wash Metal Fabncation Packaging Chemical Manufactunng Metal Finishing Pharmaceutical Manufactunng Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling ' Electncal Component Anodizing Power Generation Manufactunng Coating (1 e phosphating) Pnnt Shop Fertilizer Manufactunng Chemical Etching / Milling Research and Development Film/X-ray Processing Pnnted Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufactunng Glass Manufactunng Metal Powders Forming Soap / Detergent Manufactunng Industrial Laundry Waste Treatment / Storage SIC Code(s) (if known) Bnef descnption of business activities (Production / Manufactunng Operations) Descnption of operations generating wastewater (discharged to sewer, hauled or evaporated) Estimated volume of industrial wastewater to be discharged (gal / day)' List hazardous wastes generated (type / volume) Date operation began/or will begin at this location Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authonty'? Yes No If yes, when Site Contact_ Signature Title Phone No ENCINA WASTEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760)438-3941 F/\X (760)476-9852 DISCHARGE PERMIT EXEMPT LIST The commercia! enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under nomrial operating conditions. They are exempt because (a) they discharge no process wastewater (i.e , they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. Automobile Detailers Barber/Beauty Shops Business/Sales Offices Carpet/Upholstery Cleaning Services Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no car wash/auto repair) Grocery Stores (no film developing) Home-based Businesses Hotels/Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries Museums Nail Saions Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services Public Storage Facilities JXI Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) Product Specifications for the Uhlmann Type T Umbrellas The Frame Ideal for shading small to medium areas, the Type T Umbrellas are manufactured with 8 exceptionally strong roof supporting arms The tried and tested telescopic system and state of the art gearbox are located inside the mast. The longer roofing arms are reinforced inside for increased rigidity. All arms are individually and easily replaceable. Joints are made of high quality steel. Standard powder coating is RAL 9016 Traffic White Optional colors include black, gray, silver and bronze, wood and marble. 6 Outside Dimensions- Round from 3 00 m to 6 5 m diameter (approx 9' 10" to 21' 4" ) Square from 2x2 to 5x5 meters (approx 6' 7" x 6' 7" to 16' 5" x 16' 5" ) Rectangular from 2.5x2 to 6.5x4 meters (approx 8' 2" x 6' 7" to 21' 4" x 13' 1" ) Mast Diameter- 80mm (approx 3 1/8" ) Matenal Thickness: 3mm or 4mm (approx 1/8 or 5/32 mches) Arm Dimensions: 35x25x2mm or45x25x2mm (approx. 1 3/8 x 10 X 1/12 inches 1 3/8 X 10 X 1/12 inches ) The Mechanics and Drive Telescopic design with fixed hub. The roof arms are attached individually to the telescope plate The supporting arms are attached individually to the mast plate The mast plate is welded to the mast. Operated by crank handle that locks automatically at every position to prevent accidental opening or closing of the umbrella. Almost all umbrellas close above table level. The Canopy Dolan (or Sunbrella) - a strong awning and manne grade material 100% solution dyed Sunacrylic fabric, 290 g/m^ weight, 90% UV filter, Cleangard treated 22 standard colors (11 of them fire retarding) and 50 plus specialty colors Airtex - Acrylic/Teflon on top side - a lighter weight material 195 g/m^ weight, 80% UV filter, temperature resistance -20C° to 70C° 28 standard colors Optional Accessories • Rain gutters for continuous weather protectton connect square and rectangular umbrellas, or connect umbrellas to a building Gutters can be applied to umbrellas with or without valance • Easy to attach and remove side panels with optional transparent windows (up to 54" tall) and roll-up door - are also available with skirting - can be applied to umbrellas with or without valance • Screen-Printing on roof sections or valances available up to up to 3 45m x 14m size and up to 6 colors • Protective covers matched to umbrella size to shield canopy from dirt during installation and stonng • Heaters - energy efficient Tansun Rio 015 230V 1500W 6 5A infrared heaters with extreme shock resistant heater elements with 5000 hrs service life - four per umbrella - mounted on fold down arms, using curly cables - wiring must be done at the time of assembly • Light Fixtures - OSRAM Dulux Bnk® EL 9W or OSRAM Lumilux Bnk® EL 18W - complete with energy efficient, long lasting lamps - four per umbrella - mounted on the mast - wiring must be done at the time of assembly Warning: Umbrellas cannot be retro-fitted for heaters and or lights after the frame is assembled Pre-wiring is recommended at the time of ordering Installations Permanent Installation In-Ground Sleeve Base Plate Installation Permanent Installation Concrete Base Size Base Plate Size Concrete Base Size Permanent Installation cm inches cm inches cm inches Up to 23 0 ( 250 ft=) 60x60x60 24x24x24 30x30 12x12 150x150x10 60x60x4 From 23.5 - 48 0 m^ (251 ft^ - 520ft^) 80x80x60 32x32x24 50x50 20x20 160x160x15 62x62x6 Over 48.0 m^" (251 ft^) 100x100x60 40x40x24 50x50 20x20 165x165x20 64x64x8 We offer two types of permanent installations for exceptionally safe operation Also available are custom solutions for permanent installation on rooftops and terraces, and stair step solution to bnng umbrellas installed on different levels to the same height Two sizes of portable stands are available to easily relocate umbrellas The maximum size umbrellas recommended for portable base installation are up to 5 m diameter round (up to 16'5" diameter), 5x5 meter square (16'5"xl6'5"), or 6 5 x 4 m rectangular (2r4"xl3'l") sizes Height adjustment for each corner of the base is standard, and portable bases for smaller Type T umbrellas are available with optional castor wheels Contact us at www uhlmann-commercialumbrellas.com The dimension of the foundation may NOT be smaller than the dimensions specified below The location of the in-ground sleeve must be selected such way that it will allow 20 cm (8 inches) distance between the edge of the open umbrella and a building or any other obstacle, such as a bar counter, gnll, serving island, fence, rails, etc When several umbrella will be installed in close proximity, a 20 cm (8 inches) distance should be allowed between the edges of the open umbrellas The top of the in-ground sleeve plate should be 8 mm below the ground level to allow the upper sleeve plate to tae flush with the ground level Mast Type T/TS 0 80 mm Clamp screw M lOx 30 mm UHLMANN Counter screw M lOx 16 mm Upper sleeve M 10 X 20 mm W1SKA connector Upper sleeve plate 150 X150 X 8 mm C^ing pipe Cable Power cable tn casing pipe (this portion of the cable and the casing pipe are not Included) - Umbrellas with lighting wll need 2 wires of 1,5 mm'' • Umbrellas with heating will need 3 wiros of 4 mm' - Umbrellas with lighting and heating *ll| need 2 wires of 1,5 mm' and 3 wires of 4 mm' [ -tn>grond sleeve plate ISO X 150 X 12 mm In-ground sleeve 0 60 mm Type Round Umbrella size Square Rectangular Foundation size L X W X H T 3 m to 6 m 2 X 2 m to 4,5 x 4.5 m 2,5 X 2 m to 4,5 X 4 m 60 X 60 X 60 cm T 5,5 lo 6,5 m 5x 5 m 5x2,5 to 6,5 X 4,5 m 80 X 80 X 60 cm TS 3 to 4 m --80 X 80 X 60 cm TS -3x3to4x4m 4x3m 80 X 80 X 80 cm UMUKELLAS 0 0 S? ^ CB130896 2100 COSTA DEL MARRD LEGENDS REST-BUILD NEW 7' q/q(l5 fl^-fco^'^ 5-/5//f3 r^TX - P d) ^C^^'-^ ^ • CV nnai Insp Approved Date By BUILDING 57 PLANNING ENGINEERING FIRE Expedite? Y '(H) AFS Checked by HazMat APCD Health t Rec d Dl e^ ' y Enema H/S-Ji^ Y N Fire Y N HazHealthAPCD Y N PE&M Y N School Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD Y N LandUse Density ImpArea FY Annex Factor PFF Y N Comments Date Date Date Date Building Planning Engmeenng VZ/i/i-^ Fire —• f - Need? ^ ^ Moone -t-T€^ \ p^one • Done a Done • Done pv^ssued