Loading...
HomeMy WebLinkAbout2100 COSTA DEL MAR RD; ; CB131443; Permit07-12-2013 City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB131443 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2100 COSTA DEL MAR RD CBAD Tl Sub Type COMM 2165900100 Lot# 0 $26,206 00 Construction Type 3A Reference # Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* ISSUED 06/12/2013 LSM 07/12/2013 07/12/2013 LEGENDS RESTAURANT- 521 SF Tl TO EXISTING RESTAURANT TO INCLUDE A NEW SELF-SERVE BUFFET Applicant CHRIS MARESCA Owner L C INVESTMENT 2010 INC 2206 ALBATROSS ST SAN DIEGO CA 92101 619-238-0661 1601 ELM ST DALLAS TX 75201 Building Permit $288 01 Meter Size Add'l Building Permit Fee $0 00 Add'l Red Water Con Fee $0 00 Plan Check $201 61 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $5 50 PFF (3105540) $0 00 Park Fee $0 00 PFF (4305540) $0 00 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $102 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $103 80 Other Building Fee $0 00 MECHANICAL TOTAL $0 00 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Red Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SBl473) Fee $1 00 HMP Fee 9? Fire Expedidted Plan Review $0 00 Green Bldg Standards Plan Chk 99 TOTAL PERMIT FEES $701 92 Total Fees $701 92 Total Payments To Date $701 92 Balance Due-$0 00 Inspector FINAL APPROVAL Date f^-So-(J^ Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen-ed to as "tees/exactions" You have 90 days from the date this pemnit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired "^PLANNING CB^GINEERING C3^UILDING ^FIRE CSIHEA THE FOI LOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE IHEALTH •HAZMAT/APCD ^ C I T r OF CARLSBAD Building Permit Appiication 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www carlsbadca gov Plan Check No. (2fi>/'2> I WW'S Est. Value cS^^ Plan Ck. Deposit ^PiO Ulai Date /3 SWPPP CT/PROJECT (t LOT H PHASE # » OF UNITS * BEDROOMS » BATHROOMS TENANT BUSINESS NAIVIE CONSTR TYPE OCC GROUP Legends Restaurant lll-A A-2 JOB AODRESS 2100 Costa Del Mar Road, Carlsbad, CA 92009 SUITE|l/SPACE</UNIT« 216 123 03 05 DESCRIPTION OF WORK /nc/ude Square Feet or Affected Araa(s) 521 SF TENANT IMPROVEMENT OF AN EXISTING RESTAURANT TO INCLUDE A NEW SELF-SERVE BUFFET AND EXHIBITION BUFFET EXISTING USE Restaurant PROPOSED USE Restaurant GARAGE ISF) PATIOS (SFI DECKS (SFI FIREPUCE YESQ* NOm AIR CONDITIONING YES [7] NO I I FIRE SPRINKLERS YES[71NO| I APPLICANT NAME (Primary Contact) Dennis Kinsley APPLICANT NAME (Secondary Contact) Chris Maresca ADDRESS 2100 Costa Del Mar Road 2206 Albatross St. CITY Carlsbad STATE CA ZIP 92009 San Diego STATE CA ZIP 92101 PhONE 760-930.7075 FAX 760-931-7557 PHONE 619-238-0661 619-238-0695 EMAIL dkmsley@lacosta.com EMAIL cmaresca@.skindesignstudio com PROPERTY OWNER NAIVIE LC TRS Inc. CONTRACTOR BUS NAME N/A ADDRESS 2100 Costa Del Mar Road ADDRESS CITY Carlsbad STATE CA 92009 CITY ZIP FAX PHONE EMAIL EMAIL ARCH/DESIGNER l«ME & ADDRESS S.K.I.N. Inc. San Dieao. CA 92101 C-32449 CITl' BUS LIC » (Sec 7031 5 Business and Professions Code Any City or County which requires a pernnit to construct alter, improve demolish or repair any structure, prior to its loouanco also requires tho applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or (hat he is exempt ihererrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subiects the applicant to a civil penalty of not more lhan five nundred dollars ($500)) Workers' Compensation Declaration / hereby affirm under pens/ly of pew one of (Ae ioilomng declarations _ I Iiave and will maintain a cenificata of consant to self insure (or workers compensalion as provided by Section 3700 of (he Labor Code, lor Uie perfomiance of Ihe work for which lliis (jermit is issued 11 have and will maintain workers' compensation as required bv Secllon 3700 of Ihe Labor Code lor the perfomiance of the work (or which this oemiil is issued My workers compensation insurance camer and polcy number are Insurance Co . Policy No Expiration Dote Th;s section need nol be completed if the permit is lor one hundred dollars (SlOO) or less [7] Certificate of Exemption I certily lhal in Ihe perfonnanco of Ihe work for which Ihis perniil is issued, I shall nol employ any person in any manner so as lo become subject to Ihe Woriiers' Compensation Laws of CaUfomia WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to cnminal penalties and civil fines up to one hundred thousand dollars (&10O,O0O), in addition to the cost of compensatlan, damages as provided for in Section 3706 of the Labor code interest and attomey's fees CONTRACTOR SIGNATURE • AGENT DATE I hereby affirm Itmt I am e<emp/ from Contractors License Law for (/le foflomng reason I I I as owner of the property or my employees wilh wages as Iheir sole compensation will do Ihe work and Ihe stmcture is nol intended or offered (or sale (Sec 7044, Business and Professions Code The Contrador s License Law does nol apply to an owner of property who builds or improves Ihereon and who does such work himsell or (hrough his own employees, provided that such improvemenls are nol inlended or offered for sale If however Ihe building or improvement is sold within one year of completion, Ihe owner builder mil have the burden of proving that ha did not build or improve (or Ihe purpose of sale) [3 • I as owner of the property am exclusively contracling with licensed contractors lo construct the projecl (Sec 7044 Business and Professions Code The Contractor's Ucense Law does not apply to an owner of propprty who builris or improves thereon and conlracls (or such projecis with conlrac(or(s) licensed pursuant lo Ihe Contractor's License Law) I am exempt under Cection _ _Business and Professions Code for this reason I personally plan lo provide Ihe major labor and matenals for constnjction of Ihe proposed property mprovement Q^Yes I INO 2 I (have / have not) signed an application (or a building pemut (or Ihe proposed work 3 I have contracted with (he (ollowing person (firm) lo provide the proposed construction (include name address / phone / conlraaors license number) 4 I plan to provide portions ol the work, but I have hired the followmg person to coordinate supervise and provide the major work (mclude name / address / phore / contractois license numbei) 5 I will provide some o( !he vmrk but I have contracted (hired) Ihe (ollowing persons to provide the work indicated (include name / address / phone / lype of work) .^PROPERTY OWNER SIGNATURE GENT PATE A/L /r<, Is the applicanl or luture building occupant required lo submit a business plan acutely hazardous matenals registration lorm or nsk management and prevention program under Sections 25505,25533 or 25634 ol the Presley Tanner Hazardous Substance Account Acf Yes / No Is the applicanl or (ulure building occupani reguiied to obtain a pemiit (rom the air pollution control distnct or air quality management distncl'' Yes No Is the (acilily lo be constructed within 1 000 (eet of the outer boundary of a school site'' Yes / No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT 8E ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affimi that thero is a construction lending agency for Ihe performance of the work this permil is issued (Sec 3097 (i) Civil Code) Lender s Name WA Lender's Address I certify Uiatl have read dieapplicalionaiidstatettiatttieaboveinfomiabon Isconectand that the Inloimationon the plans Is accuiate lagieetocomplywith all Cityoidinancesand State laws relatingto bulldlngconstnictlon I hereby aulionze represenlate of Ihe City cf Cadsbad to enter upon tne above mentioned property kx inspedMn purposes I ALSO AGREE TO SAVE INDEMNIFY AMD KEEP HARVILESS THE CfT' OF CAPLSBAD AGAINST ALL LIABILfriES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA pemiit IS required for excavalions over 5 0' deep and demdilion or consliudion of slmclures over 3 stones in heighl EXPIFIATION Eveiy pemiit issued by the Building Oflicial under Ihe provisons ofthis (Me shall expie by limitation and become nul and void if the building or vroik authonzed by such pemiit is not commenced within ISOdaysfnomlhedaeolsuch pemiil or ,f Rebuilding or wik authonzed by such pemiit is suspended or abandoned al any lime after the wik E commenced for a penod of 180 days (Section 106 4 4 Unta BuiWing (Me) yfiS'APPLICANTS SIGNATURE j^AIA DATE Al lA STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTtFSCATE OCCUPAMCY ICammeecist Projects Oniy) Fax (760) 602-8560 Email buildinclScarlsbadca gov or Mail the completed form to Citv of Carlsbad Building Division 1635 Faraday Avenue Carlsbad California 92008 C0#. (Office Use Only) CONTACT NAME OCCUPANT NAME BUILDING ADORESS CITY STATE Carlsbad CA OCCUPANTS BUS LIC No DEUVERY OPTIONS PICK UP CONTACT (Listed above) CONTRACTOR (On Pg 1) MAILTO CONTACT (Listed above) CONTRACTOR (On Pg 1) OCCUPANT (Listed abovo) OCCUPANT (Listed above) ASSOCIATED CBS- MAIL/FAX TO OTHER NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION >eJAPPUCANT'S SIGNATURE DATE Inspection List Permits CB131443 Type Tl COMM LEGENDS RESTAURANT-521 SF Tl TO EXISTING RESTAURANT TO INCLU Date Inspection Item Inspector Act Comments 10/25/2013 89 Final Combo - Rl WILL GIVE YOU CARD 10/25/2013 89 Final Combo PD AP 09/10/2013 14 Frame/Steel/Bolting/Weldin PD AP Wednesday, October 30, 2013 Page 1 of 1 cnv OF RECORD COPY CB131443 2100 COSTA DEL MAR RD LEGENDS RESTAURANT- 521 SF Tl TO EXISTING RESTAURANT TO INCLUDE A NEW SELF-SERVE BUFFET Tl COMM Lot# CHRIS MARESCA P^M'^'^^H^? INSPECTION RECORD Building Division 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB m CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Cartsbadca.qov/Buildinq AND CLICK ON "Request Inspection'y DATE: -77/2'//'^ IF "YES " IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FlNAL BUILDING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 760-602-8560. EMAIL TO BLDGINSPECTIONS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE., CARLSBAD, CA 92008. BUILDING iNsptecTORS CAN BE REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR INSPECTION. NO uYES Required Prior to Requesting Building Final If Checiced YES Date Inspector Notes Planning/Landscape 760-94'4-8463 Allow 48 hours / CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm Fire Prevention 760-602-4660 Allow 48 hours Type of Inspeetion Type of Inspection CODE # BUILDING Date Inspector CODE # ELECTRICAL Date |ijspector #11 FOUNDATION #31 • ELECTRIC UNDERGROUND QUEER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 IVIASONRY PRE GROUT #33 • ELECTRIC SERVICE • TEMPORARY • GROUT • WALL DRAINS #35 PHOTOVOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS CODE # MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPir(G #14 SUBFRAME • FLOOR DCEIUNG #44 DDUCTa PLENUM • REF. PllPING #15 ROOFSHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT SHEAR PANELS #49 FINAL #16 INSUUTION CODE * COMBO INSPECTION #18 EXTERIOR lATH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH Se DRYWALL #82 DRYWALL.EXT UTH, GAS TES (17,18,23) #51 POOLEXCA/STEEL/BOND/FENCE #83 ROOFSHEATING, EXTSHEAR(I^.IS) #5S PREPUSTER #84 FRAME ROUGH COMBO (14,24,^4,44) #19 FINAL #85 T-Bar (14,24,34,44) CODE # PLUMBING Date Inspector #89 FINAL OCCUPANCY (19,29,3^,49) #22 • SEWER & BL/CO • PL/CO // FIRE . Date Inspector #21 UNDERGROUND PWASTE • WTR #24 TOPOUT DWASTE DWTR -—* — E ^ A/S UNDERGROUND VISUAL iSk #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO \ #23 DGAS TEST DGAS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL L i^ .M^ #28 SOUR WATER A/S OVERHEAD HYDROSTATIC , , Z <(S>,'2<z>tS #29 FINAL A/S FINAL 4pDE« STORMWATER F/AROOGH-IN #600 PRE-CONSTRUCTION MFETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICETO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST 1 #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL 1 #609 NOTICE OFVIOUTION MEDICAL GAS PRESSURE TEST i . , 1; . #610 VERBALWARNING MEDICALGAS FINAL V REV 10/2012 SEE BACK FOR SPECIAL NC.tS EsGil Corporation In (Partners Hi-p witli government for (ButCdtng Safety DATE 7/8/13 • APPLICANT QOtlRIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1443 SET II PROJECT ADDRESS 2100 Costa Del Mar Rd. PROJECT NAME Buffet Addition to Legends Restaurant, La Costa Resort XI The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to XI EsGll Corporation staff did not advise the applicant that the plan check has been completed I I EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person • REMARKS By Chuck Mendenhall Enclosures EsGll Corporation • GA • EJ • PC 7/1/13 EsGii Corporation In ^PartnersHip witH government for (ButCding Safety DATE 6/20/13 • APPLICANT J^r JURIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1443 SETI PROJECT ADDRESS 2100 Costa Del Mar Rd. PROJECT NAME Buffet Addition to Legends Restaurant, La Costa Resort I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X The applicant's copy of the check list has been sent to SKIN Architects, Att'n Chns Maresca 2206 Albatross St, San Diego, CA 92101 I I EsGll Corporation staff did not advise the applicant that the plan check has been completed IX EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Chns Maresca Telephone # (619) 238-0661 Date contacted (by^^^^S^ Email cmaresca@skindesignstudio com , Fax # (619) 238-0695 ^V^JVIail Telephone Vpax In Person • REMARKS- By Chuck Mendenhall Enclosures EsGll Corporation • GA • EJ • PC 6/13/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 13-1443 JURISDICTION Carlsbad OCCUPANCY A-2 USE Buffet Area TYPE OF CONSTRUCTION III A ACTUAL AREA 520 sq ft Improvement ALLOWABLE FLOOR AREA no change STORIES no change HEIGHT no change SPRINKLERS'? yes OCCUPANT LOAD 15 REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE PLANS RECEIVED BY ESGIL CORPORATION 6/13/13 DATE INITIAL PLAN REVIEW COMPLETED 6/20/13 PLAN REVIEWER Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Please make all corrections, as requested in the correction list Submit FOUR new complete sets of plans for commercial/industnal projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engmeenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete Health Dept approval is required pnor to issuance ofthe building permit by the City Show on the lighting plan on sheet A3 0 that all new lighting will be controlled by motion sensor light controls as listed on energy form LTG-1 C on sheet T-24 of the plans Note on detail 2/P1 0 that all dram lines will slope a mm %" 12" Provide complete kitchen hood mechanical plans, details, and calculations to show compliance with CMC, Chapter 5, Part II for the area above the new induction burners Specify the type of hood ( Type I grease hood or Type II fume hood ) based on the food to be cooked on the induction range • Provide exhaust sizing calculations for kitchen hoods CMC 508 4 • Show the required replacement air for each kitchen hood Include an air balance schedule CMC 511 3 • Clearly show the matenal used to construct the hood and exhaust duct CMC Section 508 1 1 • A fire damper is required at the connection of the supply air outlet to the shell of the hood assembly Include the damper location and access panel required on the plans CMC 508 5 & 510 3 • Provide grease duct air velocity calculations (Minimum 500 fpm, Maximum 2,500 fpm) CMC 511 2 • Provide a section detail for the hood showing the relative dimensioned locations for the hood, ceiling, and overhead construction framing of the floor or ceiling Be sure to descnbe the construction matenals (combustible, limited combustible or non-combustible) used adjacent to the hood and duct CMC 507 2 • The duct routing shall be as direct as practical to the extenor of the building CMC 510 12 • Provide construction details for the fire rated grease duct enclosure Note Clearance distance from the grease duct to the enclosure inside face is not less than 6" (non- combustible) and 18" (combustible) CMC Sections 5107& 510723 A duct shaft is required in all multistory buildings and in 1 story buildings with rated roof/ceiling assemblies Provide a shaft design complying with CMC 510 7 2 and 510 7 3 on the plans The duct shaft size exceeds the building framing spacing Revise the duct and shaft size or detail the modifications necessary to the building framing Detail the slope (1/4"/foot/minimum) on the honzontal grease duct back towards the hood CMC 510 1 4 Show the required cleanouts for the grease duct o At changes in direction and o Horizontal ducts require at least one 20 X 20" opening for personnel entry o Ifthe duct IS not accessible from a 10' stepladder, a platform is required Please detail CMC 510 34 1 2 o Vertical ducts require an access at the top or, if personnel entry is not possible, a cleanout at each floor level Detail the kitchen hood duct termination clearances as per CMC 510 8 A complete kitchen hood system plan review will be done when the complete hood system plans, details, and calculations are provided END OF CODE REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 13-1443 PREPARED BY Chuck Mendenhall DATE 6/20/13 BUILDING ADDRESS 2100 Costa Del Mar Rd. BUILDING OCCUPANCY A-2 TYPE OF CONSTRUCTION III A BUILDING PORTION AREA ( Sq Ft) Valuation Multiplier Reg Mod VALUE ($) Tl 520 City Est 26,206 Air Conditioning Fire Sprinklers TOTAL VALUE 26,206 Junsdiction Code cb By Ordinance Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review 0 Complete Review [^Repetitive Fee ^ Repeats • Other Hourly EsGil Fee • Structural Only Hr @ * $288 01 $187.21 $161.29 Comments Sheet 1 of 1 macvalue doc + PLAN CHECK PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 FaradayAvenue CARLSBAD TRANSIVIiTTAL Carlsbad CA 92008 w/ww carlsbadca gov DATE: 6/27/13 PROJECT NAME:Legends Restaurant(La Costa Resort) PROJECT ID: PLAN CHECK NO: CB131443 SET#:I ADDRESS: 2100 Costa Del Mar Rd APN: 216-123-03 VALUATION: $26,206 APPLICANT CONTACT: cmaresca(g)skindesignstudio.com X This plan check review transmittal is to notify you of clearance by: LAND DEVELOPIVIENT ENGINEERING DIVISION Final Inspection by the Construction & Inspection Division is required: Yes LZI /Vo IX| ^ For status from a division not marked below, please call 760-602-2719 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. PLANNING 760-602-4610 LAND DEVELOPMENT ENG. 760-602-2750 FIRE PREVENTION 760-602-4665 ^1 Chris Sexton 760-602-4624 Chns Sextoiva'cai Isbadca gov [ 1 Gina Ruiz — 760-602-4675 Gma RuizOcarlsbadca gov Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov X Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov "I Greg Ryan J 760-602-4663 Grcgory.RyanCacarlsbadca gov Cindy Wong 760-602-4662 Cynthia WongQcarlsbadca gov Dommic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks ^ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 FaradayAvenue (760) 602-4610 www carlsbadca eov DATE: 6/14/13 PROJECT NAIVIE: INTERIOR Tl PROJECTID: PLAN CHECK NO" CB131443 SET#: ADDRESS: 2100 COSTA DEL MAR RD APN: ^ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division IS required QYes ^NO You may a/so have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted pians shouid include corrections from ail divisions. Q This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required Plan Check APPROVAL has been sent to: CMARESCA@SKINDESIGNSTUDI0.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING . 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chns Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 Greg Ryan 760-602-4663 Gregorv RvanOcarlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Lmda Ontiveros@carlsbadca gov [Z] Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • [ 1 Dommic Fieri 760-602-4664 Dommic Fien@carlsbadca gov Remarks: CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 07/10/2013 PROJECT NAME: LEGENDS RESTAURANT PROJECT ID: CB131443 PLAN CHECK NO: 2 SET#: 1 ADDRESS: 2100 COSTA DEL MAR APN: • This plan check review is complete and has been APPROVED by the FIRE Division. By: GR A Final Inspection by the FIRE Division is required ^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: S.K.I.N. You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on thie attached cliecklist please contact thie following reviewer as nnarked: PLANNING 760-602-4610 «i£3FIRE'.^REVENTI0N 1 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca fiov X Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Lmda Ontiveros@carlsbadca gov Cindy Wong 760-602-4662 Cynthia Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca.gov Remarks: See Attached Carlsbad Fire Department Plan Review Date of Report: Name. Address" Requirements Category Tl, COMIVl 07-10-2013 CHRIS MARESCA 2206 ALBATROSS ST SAN DIEGO CA 92101 Reviewed by: Permit #: CB131443 Job Name- Job Address: LEGENDS RESTAURANT- 521 SF 2100 COSTA DEL MAR RD CBAD Please review carefully all comments attached. CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW Entry: 07/10/2013 By: GR Action. AP ayiLDlMQ DEI i ^ CITY OF CARLSBA PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 06/18/2013 PROJECT NAME: LCRS - LEGENDS RESTAURANT PROJECT ID: CB131443 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2100 COSTA DEL MAR RD APN: • This plan check review is complete and has been APPROVED by the FIRE Division. By: GR A Final Inspection by the FIRE Division is required ^ Yes • No XI This plan check review Is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: S.K.I.N. Inc. You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the followmg reviewer as marked- PLANNING 760-602^4610 ENGINEERilNG 760-602-27450 FIRE PREVENTION »>i„ .~ 760-602-46J35 1 1 Chris Sexton 760-602-4624 Chns SextonOcarlsbadca gov 1 Kathleen Lawrence 760-602-2741 Kathleen LawrenceOcarlsbadca gov X Greg Ryan 760-602-4663 Gregory Ryan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Lmda OntiverosOcarlsbadca gov Q Cindy Wong 760-602-4662 Cynthia WongOcarlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic FieriOcarlsbadca gov Remarks: See Attached Carlsbad Fire Department Plan Review Date of Report- Name Address Requirements Category TI,COMIVI 06-18-2013 CHRIS MARESCA 2206 ALBATROSS ST SAN DIEGO CA 92101 Reviewed by Permit # CB131443 Job Name Job Address LEGENDS RESTAURANT- 521 SF 2100 COSTA DEL MAR RD CBAD INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions: Cond: CON0006416 [NOT MET] Any room having an occupant load of 50 or more, where fixed seats are not mstalled, and which is used for assembly or similar purpose, shall have the capacity of the room posted in a conspicuous place Provide note on plans sheet A2 0 detailing placement location for sign and proposed occupant load(s) Cond: CON0006415 [NOT MET] When two or more exits from a story are required by the California Building Code, exit signs shall be installed at horizontal exits and other required exits from the story. When two or more exits are required from a room or area, exit signs shall be installed at the required exits from the room or area and where otherwise necessary to clearly indicate the direction of egress Exit signs shall be contrasting in color and color spectrum Cond: CON0006414 [NOT MET] Provide on Sheet AO 0 the calculated Occupant Load. Provide detail of Occupant Load sign and indicate proposed location on A2 0 Cond: CON0006417 [NOT MET] Provide portable fire extinguishers as required The number and location of fire extinguishers is to be determined by the fire department, however you are to indicate that on the title sheet that this plan shall be in compliance with the 2010 California Fire Code, NFPA 13 (2012 ed ), 10 (2008 ed ) and 24 (2010 ed ) Cond: BP016 [NOT MET] Provide exit door hardware, which is openable from the inside without the use of a key or any special knowledge or effort Show on door schedule location and type of hardware proposed Note Automatic door hold-open devices may require listed releasing devices when installed in rated assemblies Cond: BP020 [NOT MET] Exits shall be illuminated at any time the building is occupied with light having intensity of not less than 1-foot-candle at floor level. The power supply for exit illumination shall comply with the Building Code STORM WATER Development Services %wpA CITY OF CARLSBAD COMPLIANCE ASSESSMENT B-24 Building Division 1635 FaradayAvenue 760-602-2719 www carlsbadca gov I am applying to tlie City of Carlsbad for the following type(s) of construction permit' Building Permit • Riglit-of-Way Permit Is My project IS categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Critena ^ My project qualifies as NO THREAT and is exempt from ttie requirement to prepare a storm water pollution prevention plan (SWPPP) because \ it meets ttie "no ttireat" assessment criteria on tfie City's Project Threat Assessment Workstieet for Determination of Construction SWPPP Tier Level My project does not meet any of ttie High, Moderate or Low Threat criteria descnbed below Tierl - Low Threat Assessment Cntena • My project does not meet any ofthe Significant or Moderate Threat cntena, is not an exempt permit type (See list above) and the project meets one or more ofthe following criteria • Results in some soil disturbance, and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling) Tier 2 - Moderate Threat Assessment Criteria • My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more ofthe following cntena • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 1516 ofthe Carlsbad Municipal Code), or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more ofthe additional following criteria • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm dram inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct 1 through April 30) T/er3 - Significant Threat Assessment Cntena • My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas and/or • My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas or, • My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s) / certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times dunng construction activities for ihe permit type(s) check above comply with the storm water best management practices pursuant to Title 15 ofttie Carlsbad Municipal Code and to City Standards The Qty Engineer nnay auttionze minor vanances from the Storm Water Threat Assessment Cntena in speaal arcunnstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is warranted Pro|ecl Adttess Assessor Parcel No Owner/Owner's Authonzed Agent Name Agent Signature Tile ^7-9-/4^2. B-24 Page 1 of 1 Rev 03/09 STORM WATER Development Services Engineering Department STANDARDS Development Services Engineering Department ^ CITY OF QUESTIONNAIRE 1635 Faraday Avenue CARLSBAD E-34 760-602-2750 www carlsbadca gov INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment pnonty projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP) Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits) The results ofthe questionnaire determme the level of storm water standards that must be applied to a proposed development or redevelopment project Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject additional critena called 'Pnonty Development Project Requirements' Many aspects of project site design are dependent upon the storm water standards applied to a project Applicant responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts City staff has responsibility for making the final assessment after submission of the development application If staff determines that the questionnaire was incorrectly filled out and is subject to more stnngent storm water standards than initially assessed by the applicant, this will result in the return of the development application as incomplete In this case, please make the changes to the questionnaire and resubmit to the City If applicants are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, they are advised to seek assistance from Land Development Engineering staff A separate completed and signed questionnaire must be submitted for each new development application submission Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently In addition to this questionnaire, applicants for construction permits must also complete, sign and submit a Project Threat Assessment Form to address construction aspects ofthe project Please answer the questions below, follow the instructions and sign the form at the end 1 Is your project a significant redevelopmenf^ DEFINITION: Significant redevelopment is defined as the creation, addition or replacement of at least 5,000 square feet of impervious surface on an already existing developed site Significant redevelopment includes, but is not limited to the expansion of a building footpnnt, addition to or replacement of a structure, structural development including an increase in gross floor area and/or extenor construction remodeling, replacement of an impervious surface that is not part of a routine maintenance activity, and land disturbing activities related with structural or impervious surfaces Replacement of impen/ious surfaces includes any activity that is not part of a routine maintenance activity where impervious matenal(s) are removed, exposing underlying soil dunng construction If your project IS considered significant redevelopment, then please skip Section 1 and proceed with Section 2 If your project IS NOT considered significant redevelopment, then please proceed to Section 1 E-34 Paget of 3 REV 3/23/10 STORM WATER Development Services Engineering Department STANDARDS Development Services Engineering Department CITY OF QUESTIONNAIRE 1635 Faraday Avenue CARLSBAD E-34 760-602-2750 www carlsbadca gov SECTION 1 NEW DEVELOPMENT PRIORITY PROJECT TYPE Does you project meet one or more of the following cntena YES NO 1 Housina subdivisions of 10 or more dwellina units Examoles sinale familv homes, multi-familv homes, condominium and apartments 2 Commercial - areater than 1-acre Anv develooment other than heaw industrv or residential Examoles hosoitals. laboratories and other medical facilities, educational institutions, recreational facilities, municipal facilities, commercial nurseries, multi-apartment buildings, car wash facilities, mini-malls and other business complexes, shopping malls, hotels, office buildings, public warehouses, automotive dealerships, airfields, and other light industrial facilities X 3 Heaw Industrial / Industry- areater than 1 acre Examoles manufacturina olants, food orocessina olants. metal working facilities, pnntmg plants, and fleet storage areas (bus, truck, etc) X 4 Automotive repair shop A facility cateaorized in anv one of Standard Industnal Classification (SIC) codes 5013. 5014, 5541, 7532-7534, and 7536-7539 X 5 Restaurants Anv facility that sells oreoared foods and dnnks for consumotion. includina stationarv lunch counters and refreshment stands selling prepared foods and dnnks for immediate consumption (SIC code 5812), where the land area for development is greater than 5,000 square feet Restaurants where land development is less than 5,000 square feet shall meet all SUSMP requirements except for structural treatment BMP and numeric sizing criteria requirements and hydromodification requirements X 6 Hillside development Anv develooment that creates 5,000 sauare feet of imoervious surface and is located in an area with known erosive soil conditions, where the development will grade on any natural slope that is twenty-five percent (25%) or greater X 7 Environmentallv Sensitive Area (ESA)^ All develooment located within or directly adiacent^ to or discharaina directly^ to an ESA (where discharges from the development or redevelopment will enter receiving waters within the ESA), which either creates 2,500 square feet of impervious surface on a proposed project site or increases the area of imperviousness of a proposed project site to 10% or more of its naturally occurnng condition X 8 Parkina lot Area of 5.000 sauare feet or more, or with 15 or more oarkina soaces. and ootentiallv exoosed to urban runoff >< 9 Streets, roads, hiahwavs. and freewavs Anv oaved surface that is 5.000 sauare feet or areater used for the transportation of automobiles, trucks, motorcycles, and other vehicles X 10 Retail Gasohne Outlets Servina more than 100 vehicles oer day and areater than 5.000 sauare feet 11 Coastal Development Zone Anv oroiect located within 200 feet of the Pacific Ocean and fl) creates more than 2500 square feet of impermeable surface or (2) increases impermeable surface on property by more than 10% 12 More than 1-acre of disturbance Proiect results in the disturbance of more than 1-acre or more of land and is considered a Pollutant-generating Development Project^ X 1 Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies, areas designated as Areas ot Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments), water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments), areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego, and any other equivalent environmentally sensitive areas which have been identified by the Copermittees 2 Directly adjacent" means situated within 200 feet ofthe Environmentally Sensitive Area 3 "Discharging directly to" means outflow from a drainage conveyance system that is composed entirely of flows from the subject development or redevelopment site, and not commingled with flow from adjacent lands 4 Pollutant-generating Development Projects are those projects that generate pollutants at levels greater than background levels In general, these mclude all projects that contnbute to an exceedance to an impaired water body or which create new impervious surfaces greater than 5000 square feet and/or introduce new landscaping areas that require routine use of fertilizers and pesticides In most oases linear pathway projects that are for infrequent vehicle use, such as emergency or maintenance access, or for pedestnan or bicycle use, are not considered Pollutant-generating Development Projects if they are built with pervious surfaces or if they sheet flow to surrounding pervious surfaces Section 1 Results If you answered YES to ANY of the questions above your project is subject to Priority Development Project requirements Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 A Storm Water Management Plan, prepared in accordance with City Storm Water Standards, must be submitted at time of application If you answered NO to ALL of the questions above, then your project is subject to Standard Stormwater Requirements Please check the "does not meet PDP requirements" box in Section 3 E-34 Page 2 of 3 REV 3/23/10 ^ CITY CARLSBAD O F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 Faraday Avenue 760-602-2750 www carlsbadca gov SECTION 2 SIGNIFICANT REDEVELOPMENT Complete the questions below regarding your redevelopment project YES NO 1 Project results in the disturbance of more than 1 -acre or more of land and is considered a Pollutant-generating Development Project (see definition in Section 1) If you answered NO, please proceed to question 2 If you answered YES, then you ARE a significant redevelopment and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below 2 Is the project redeveloping an existing priority project type? (Priority projects are defined in Section 1) If you answered YES, please proceed to question 3 If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS Please check the "does not meet PDP requirements" box in Section 3 below 3 Is the project solely limited to just one of the following a Trenching and resurfacing associated with utility work' b Resurfacing and reconfigunng existing surface parking lots' c New sidewalk construction, pedestnan ramps, or bike lane on public and/or private existing roads' d Replacement of existing damaged pavement' If you answered NO to ALL of the questions, then proceed to question 4 If you answered YES to ANY of the questions then you ARE NOT a significant redevelopment and your project is subject to Standard stormwater Requirements Please check the "does not meet PDP requirements" box in Section 3 below Will your redevelopment project create, replace, or add at least 5,000 square feet of impervious surfaces on an existing development or, be located within 200 feet ofthe Pacific Ocean and (1)create more than 2500 square feet of impermeable surface or (2) increases impermeable surface on the property by more than 10%' If you answered YES, you ARE a significant redevelopment, and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS Please check the "does not meet PDP requirements" box in Section 3 below SECTION 3 Questionnaire Results • My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater critena per the SUSMP and must prepare a Storm Water Management Plan for submittal at time of application My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP J^IJBOX for City Use Only Applicant Information and Signature Box Address '^100 Co9tA 'PEL/hM.Hb. Assessor's Parcel Number(s) Applicant Name Applicant Title ApplicantStg nature Date / / City C6ncurrence / By, YgS x: NO Project I E-34 Page 3 of 3 REV 3/23/10 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / / Business Name /, Business Contact • Telephone # _ ^ ^ ^ Project Address City^ „ ' ' state e^csE^ cm- Zip-Code APN# . Mailing Address UOO COSTA t^mfr^tUhiD City state Zip Code Plan File# ' Project Contact ; ^ . D^^l^ K/AJSCBY Telephone # The following questions represent the facility's activities, NOT the specific project description PART I FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials If any of the items are circled, applicant must contact the Fire Protection Agency with junsdiction priorto plan submittal Facility's Square Footage (including proposed project) ^j'^Z.^ \ Occupancy Rating A— 1 Explosive or Blasting Agents 5 Organic Peroxides 9 Water Reactives 13 Corrosives 2 Compressed Gases 6 Oxidizers 10 Cryogenics 14 Other Health Hazards 3 Flammable/Combustible Liquids 7 Pyrophoncs 11 Highly Toxic or Toxic Matenals Q 5 None ot 1 hesg> 4 Flammable Solids 8 Unstable Reactives 12 Radioactives PART II SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD) Ifthe answer to anv of the questions is yes, applicant must contact the County of San Diego Hazardous Matenals Division, 5500 Overland Ave , Suite 110, San Diego, CA 92123 Call (858) 505-6700 pnor to the issuance of a building permit FEES ARE REQUIRED Project Completion Date y / '"2^ / / 3 Expected Date of Occupancy ^ / / ' S Date • CalARP Required / Date Initials • CalARP Complete (for new constmction or remodeling projects) Is your business listed on the reverse side ofthis form' (check all that apply) Will your business dispose of Hazardous Substances or Medical Waste in any amount' Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity' Will your business use an existing or install an underground storage tank' Will your business store or handle Regulated Substances (CalARP)' Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)' Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons' (California's Aboveground Petroleum Storage Act) PART III SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control Distnct (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 pnor to the issuance of a building or demolition permit Note if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days pnor to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less Contact the APCD for more information YES NO 1 • 2 • 3 • 4 • 5 • 6 • 7 • • CalARP Exempt J Initials / Date Initials 1 YES • NO 3 Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant' (See the APCD factsheet at http //www sdapcd org/info/facts/permits pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from Contact APCD if you have any questions) • • (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)' (Search the California School Directory at http //www cde ca qov/re/sd/ for public and pnvate schools or contact the appropnate school distnct) ^ Has a survey been perfonned to determine the presence of Asbestos Containing Matenals' jH Will there be renovation that involves handling of any fnable asbestos matenals, or disturbing any matenal that contains non-fnable asbestos' S Will there be demolition involving the removal of a load supporting structural member' • • • Briefly descnbe business activities Bnefly descnbe proposed project declare under penalty of penury that to the best of my knowledge and belief the resg ;lare under penalty of periury that to tl Name of Owner or Authorized Agent ,is made herein are true and correct Signature of Owner or Authonzed Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION . BY FOR OFFICIAL USE ONLY DATE EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASER FOR BUILOING PERMIT BUT NOT FOR OCCUPANCY RELEASER FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD A stamp in this box onlv exempts businesses from completing or updating a Hazardous Matenals Business Plan Other permitting requirements may still apply HM-9171 (02/11) County of San Diego - DEH - Hazardous Matenals Division «l» CITY OF CARLSBAD PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www carlsbadca gov Project Address: ^\CO Coi>\ei Ofiu «^ Permit No.: Information provided below refers to worb being done on the above mentioned permit only. This form must be completed and returned to the Buildinq Division before the permit can be issued. Building Dept Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains '~l New building sewer line? Ves ^ No Number of new roof drams? 0 install/alter water line? y(^S Number of new water heaters? 0 Number of new, relocated or replaced gas outlets? ^ Number of new hose bibs? 0 Residential Permits: New/expanded service: Number of new amps: Minor Remodel onl^: Ves No Commercial/Industrial: Tenant Improvement. Number of existing amps involvedin this project: Number of new amps involvedin this project- New Construction: Amps per Panel: Single Phase Number of new amperes_ Three Phase Number of new amperes_ Three Phase 480 Number of new amperes_ Number of new furnaces, A/C, or heat pumps? , New or relocated duct worb? Ves_ Number of new fireplaces? -0- No V 4 Number of new exhaust fans? ^ Relocate/install vent? JS^ Number of new exhaust hoods? ^ Number of new boilers or compressors? Number of HP B-18 Page 1 of 1 Rev 03/09 P(.0)CCTNUMBbR CARLSBAD FIRE DEPARTMENT EXPEDITED PLAN CHECK REQUEST I, am requesting 'Expedited Plan Check Services' and understand I will be levied an additional fee assessed at the rate of $90 00 dollars per hour plus $25 00 dollars administration fee I understand that my plans shall not be released until all fees are paid I, ^the applicant, am solely responsible for all fees due should the project be withdrawn or otherwise not completed And by signing below I acknowledge that my plans shall be forwarded by the City of Carlsbad to an independent contractor/consultant I, acknowledge that the 'first review' time for all expedited Fire plan reviews will be fen- (10) business days from date of submittal These additional day account for acceptance and delivery of your plans and then the parcel return to our office if recommended for approval four Mfline I, the applicant, acknowledges that corrected or revised plans shall be sent directly to the plan checker, at the address specified on the Correction List, at my cost, parcel post or other means I, acknowledge that a turn-around time for re-submittals is five- (5) business days from the date plans are received at the address specified by the plan checker on the Correction List Once all corrections are made, your plans are then returned to the Carlsbad Fire Department with a "Recommendation for Approval" based solely on the adopted Codes and Standards This is not an approval. Your plans are then forwarded to the Carlsbad Fire Department, and once your plans are received by our office they are subject to an additional review to ensure conformance with Carlsbad Municipal Code This additional review is subject to an additional review period of seven- (7) 'Government Business' days from date that we receive the plans from the plan reviewer. The Carlsbad Fire Department does not perform 'Over-the-counter' plan review services Plans submitted to the Carlsbad Fire Department for review by CFD staff shall be checked on a 'first come, first served' basis and could take 10 days or more for 'First' review YES PLEASE CIRCLE YOUR SELECTION Applicant Signature •^y O"""'^^—• Date Ml. Copy to Building and Fire Prevention file Revised 10/15/2012 INDUSTRIAL WASTEWATER DISCHARGE PERS ^) I SCREENING SURVEY Date W 3 . rr. Business Name L-^^^PS" f<^TT/^rLA^^ Street Address ^[OO Ce>S>TA- /\/\ AfZ l^oAr^p Email Address .O/C/A^C/ (==:Y A^(1O5TA . (LotA HT PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility Acid Cleaning Assembly Automotive Repair Battery Manufacturing Biofuel Manufactunng Biotech Laboratory Bulk Chemical Storage Car Wash Chemical Manufactunng Chemical Purification Dry Cleaning Electncal Component Manufactunng Fertilizer Manufactunng Film / X-ray Processing Food Processing Glass Manufactunng Industrial Laundry Ink Manufactunng Laboratory Machining/Milling Manufacturing Membrane Manufactunng (i e water filter membranes) Metal Casting / Forming Metal Fabrication Metal Finishing Electroplating Electroless plating Anodizing Coating (i e phosphating) Chemical Etching / Milling Printed Circuit Board Manufactunng Metal Powders Forming Nutntional Supplement/ Vitamin Manufacturing Painting/Finishing Paint Manufactunng Personal Care Products Manufactunng Pesticide Manufactunng / Packaging Pharmaceutical Manufactunng (including precursors) Porcelain Enameling Power Generation Pnnt Shop Research and Development Rubber Manufacturing Semiconductor Manufactunng Soap / Detergent Manufactunng Waste Treatment / Storage SIC Code(s) (if known) Bnef descnption of business activities (Production / Manufactunng Operations) Descnption of operations generating wastewater (discharged to sewer, hauled or evaporated) Estimated volume of industnal wastewater to be discharged (gal / day)" List hazardous wastes generated (type/volume) Date operation began/or will begin at this location Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authonty'? Yes No If yes, when Site Contact f^M\£ \<^KI<;:U^^ Signature, Title'|I^)^feei-o/2- thf^w^ssni^Jls^ Phone No O - - 7 C ^ ENCINA WASTEWATER AUTHORITY, 6200 Avenida Enemas Carlsbad.CA 92011 (760)438-3941 FAX (760)476-9852 RECEIVED JUL 1 2 2013 CITY OF CARLSBAD BUILDING DIVISION COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH PLAN REVIEW PROVISIONAL APPROVAL PI Aisiq ArCE°TED FOR CONSTRUCTiON SUBJECT TO THE WE^iNTS OF T5E STATE AN? LOCAL REGU ruic CTAHAD ic; MO ASSURANCE THAT THE PLANS OK bKt'^l- TSATS ARE CO^^^^^^^^^ RESPECT ERRORS IN D&?GrOR CONSTSUCT^ MUS7 BE CORRECTED PROJECT DATA PROJECT SCOPE: ADD NEW BUFFET LINE OWN E R: KSL LA COSTA RESORT CO , LLC - (760) 438-9111 OCCU PANT: LA COSTA RESORT & SPA SITE ADDRESS: 2100 COSTA DEL MAR ROAD, CARLSBAD, CA 92009 CONTACT PERSON: RICKALLYN (619)7424245 ARCHITECT: THOMAS MCCABE, 2011 B SAN ELIJO AVE , CARDIFF, CA 92007 FOODSERVICE CONSULTANT: R,CK ALLYN, CFSP 619-742-4245 PRESENT OCCUPANCY: LA COSTA RESORT (LEGENDS RESTAURANT) PROPOSED OCCUPANCY: ADDITION (BUFFET) TYPE OF BUSINESS: RESORT&SPA BUILDING AREA: WATER DISTRICT: SEWER DISTRICT: 350 S F. (ADDITION) CARLSBAD MUNICIPAL WATER DISTRICT CARLSBAD WASTEWATER DIVISION COUNTY OF SAN DiEGO DEPARTMENT OF ENVIRONMENTAL HEALTH PLAN CHECK NOTICE CALL 858-505-6660 TO SCHEDULE PRELIMINARY MID AND FINAL INSPECTION IF THERE is NO CONSTRUCTION BEGUN ^fTER ONE (I) YEAR FROM THE DATE THE PUNS WERE APPROVED, THEN ThE APPROVED PLANS VVILL BE VOIDED AND NEW PUNS MUST BE RESUBMITfED FOR APPROVAL 2 - 3 4 5 6 -7 GENERAL NOTES ALL FOOD SERVICE EQUIPMENT TO BE MANUFACTURED/FABRICATED AND INSTALLED TO COMPLY WRTH NSF AND/OR ANSI STANDARDS, BUILDING AND DEPT OF ENVIRONMENTAL HEALTH SERVICES CODE REQUIREMENTS TYPE OF THIS FOOD FACILITY IS FULL SERVICE DINING FACILITY ALCOHOLIC BEVERAGES WILL BE CONSUMED ON THE PREMISES SOFT DRINK DISPENSER IS NOT SELF-SERVICE AND NO REFILLS WILL BE SERVED NUMBER OF EMPLOYEES PER SHIFT 20 ALL LIGHTS IN KITCHEN, FOOD PREP, WORK AND STORAGE AREAS TO HAVE SHATTERSHIELDS FLOORS IN FOOD SERVICE AREAS TO HAVE A SMOOTH, EASILY CLEANED SURFACE, WITH A UGHT TEXTURE ONLY IN WALKWAYS HOT WATER SUPPLIED BY A CENTRAL BOILER SYSTEM LOCATED IN A REMOTE BOILER ROOM 9 - SQUARE FOOTAGE OF THIS FOOD FACILITY REMODEL IS APPROX 350 SQ FT 10 - ALL SEAMS, GAPS AND OPENINGS TO BE PROPERLY SEALED 11 - PAINT USED ON WALLS AND CEILINGS IN KITCHEN, FOOD PREPARATION, WORK AND STORAGE AREAS TO BE A GLOSS OR SEMI-GLOSS ENAMEL ONLY FINISHES IN ALL FOOD AREAS TO BE LIGHT IN CCS-OR TO FAClLrTATE CLEANING 12 - ALL EQUIPMENT SHALL BE PLACED ON MINIMUM 6" HIGH NSF TYPE METAL LEGS OR COMPLETELY SEALED IN POSITION ON A 4" HIGH CONTINUOUSLY COVED BASE OR CONCRETE CURB, OR APPROVED CASTERS 13 - ALL EXHAUST HOOD(S) AND DUCT(S) TO BE MANUFACTURED AND INSTALLED PER U L SPECIFICATIONS TYPE 1 HOOD DUCT MUST HAVE FULLY-WELDED. LIQUID-TIGHT SEAMS 14 -ALL UTILrriES. (PIPES, CONDUrrS. ETC.), SHALL BE CONCEALED WITHIN BUILDING STRUCTURE TO AS GREAT EXTENT AS POSSIBLE OR SHALL BE SECURED A MINIMUM OF 6" OFF FLOOR AS GREAT EXTENT AS POSSIBLE OR SHALL BE SECURED A MINIMUM OF 6" OFF FLOOR, OR 3/4" FROM WALLS WrTH STANDOFF BRACKETS 15 -A MINIMUM OF NINETY-SIX (96) LINEAR FEET OF APPROVED SHELVING UNITS ARE REQUIRED FOR BACKUP DRY STORAGE MAXIMUM FIVE (5) TIERS HEIGHT SHELVING SHALL BE A MINIMUM OF 18' DEEP BOTTOM SHELF TO BE A MINIMUM OF 6" ABOVE FLOOR 16 - FLOORS IN FOOD PREPARATION, UTENSIL/DISH WASHING AREAS, SERVICE/PICK-UP AREAS, JANITOR'S AREA, RESTROOMS, ETC, ARE REQUIRED TO GRADUALLY SLOPE 1 50 (APPROX 1/4 INCH PER FOOT) TO FLOOR DRAINS FOR PROPER DRAINAGE OF THE FLOOR 17 - DOORS, BOTH EXIT AND OPENING TQ OUTSIDE, SHALL OPEN OUTWARD AND BE SELF- CLOSING 18 - RECEIVING DOORS QH DOORS OPENING TO OUTSIDE SHALL HAVE AN AIR CURTAIN INSTALLED WHICH SHALL PROVIDE A MINIMUM AIR VELOCITY OF 1600 FEET PER MINUTE MEASURES AT 36- ABOVE THE RNISHED FLOOR AND BE ACTIVATED UPON DOOR OPENING VIA MICROSWrrCH 19 - A DESIGNATED ARE^ SEPARATE FROM TOILETS, FOOD STORAGE OR FOOD PREPARATION AREAS, SHAa BE PROVIDED TO STORE EMPLOYEE OUTER GARMENTS AND PERSONAL BELONGINGS ROOM FLOOR AREA SHALL BE A MINIMUM OF TWENTY (20) SQUARE FEET SEPARATE SEX CHANGING ROOMS WILL BE REQUIRED IN FACIUTIES WrrH TEN (10) QR MORE EMPLOYEES PER SHIFT 20 - SMOOTH CONCRETE SLAB TO BE PROVIDED FOR OUTSIDE TRASH AND GARBAGE STORAGE IF TRASH AREA IS ENCLOSED, INNER SURFACE OF WAUS TO BE SMOOTH, SEALED, AND WASHABLE (PLASTERED,* PAINTED, ETC ) SLATS IN FENCING TO BE METAL OR PLASTIC 21 - ANY OPERABLE WINDOWS, LOUVERS, OR SIMILAR VENTILATION OPENINGS SHAa HAVE TIGHT-FITTING SCREENS, WITH A MINIMUM OF 16 MESH TO AN INCH 22 - SNEEZE GUARDS TO BE PROVIDED FOR UNPACKAGED FOOD, SANITIZED MULTI-SERVICE UTENSILS, GLASSES, DISHES, AND FOOD PREPARATION AREAS SO AS TO BE PROTECTED FROM UNNECESSARY HANDLING AND INFECTION FROM CUSTOMERS PLUMBING 23 - A THREE (3) COMPARTMENT STAIN BOARDS MEETING CURRENT NSF £ WASHING MULT-SERVICE KR^CHEN SIZETOBE 18"x18"x12' DRAIN BO/ TO BE MINIMUM 8" SEALED TQ WAL 24 -A FOOD PREPARATION SINK WHEF COMPARTMENT SEPARATE FROM I REQUIRED TO DRAIN INTO A FLOOf 25 - HAND SINKS ARE REQUIRED TO BE COOKING AREAS. AND SHAa HAVE TYPE FAUCET PROVIDE 12" HIGH V WHEN DIRECTLY ADJACENT TO PRI 26 - Aa LAVATORIES AND OR HANDSIN FAUCET CAPABLE OF SUPPLY WAR 27 - HAND WASHING SINKS TO BE PROV TOWEL DISPENSER, SOAP DISPENS HAND WASHING SINKS IN RESTROC S/S SPLASH GUARDS Wia BE REa A COUNTER ON WHICH THERE IS R 28 - BAR SINKS SHAa HAVE A MINIMUM SINKS MUST MEET ALL NSF STAND/ 14*x10*x10', (QR A MINIMUM OF 140! INTEGRAL DRAINBOARDS MEETING 29 - A FLOOR MOUNTED J/UgrrORIAL SIN FOR GENER/U. FACILITY CLEANING WASTE SINK SHALL BE SUPPLIED \ OLm.ET AND APPROVED BACKFLQV LARGE ENOUGH TQ ACCQMMQDATI 30 - Aa AUTOMATIC DISHWASHERS, PA USTED BY NSF IN THE LATEST ISSU ST/UNLESS STEEL DISHTABLES A Ml A 3- DRAIN BY LEGAL AIR GAP 31 - DISH ANO GLASS WASHING MACHIN BE PROVIDED WrrH 120 DEGREE F. TIME CHEMICAL INC, #802000, CHLC 32 - Dl^ & GLASS WASHING MACHINES mm A MIN QF 120 DEGREES F HO Ta4PERATURE TQ 180 DEGREES F 33 - SINKS TO BE PROVIDED WmH A SUF RUNNING WATER UNDER PRESSURI REACHING EACH COMPARTMENT 34 - WATER SUPPLY TO CARBONATORS PRESSURE PRINCIPAL BACKFLOW f TO SEWER WITH A LEGAL AIR GAP* 35 - GREASE TRAP(S). IF REQUIRED, SH) OR IN A SEPARATE JANrrORIAL ROC RESTROOMS 36 - DOORS AT RESTROOMS, ANTE-RQO UNDERCUT ONE (1) INCH 37 - EXHAUST VENTILATION PER UMC Rt ROOMS, ANTE-ROOMS, DRESSING R EXHAUST SYSTEMS, SEPARATE FRG CC»IDmONINa THE FANS SHAa BE 38 - TOILET FACILrriES ARE REQUIRED W EMPLOYEES EXISTING FACIUTIES I FEET OF FLOOR AREA SEPARATES FAdLITlES wrm FIVE QR MORE EMf CLOSING AND TIGHT-FnTING WTTH / nriMTAOT l^lc:nn^^ATlnM • mm. CB131443 2100 COSTA DEL MAR RD LEGENDS RESTAURANT- 521 SF Tl TO EXISTING RESTAURANT TO INH I inF A NFW TO pUHj 1^1^ sw •ISSUED •cv Approved Date By BUILDING Om PLANNING IT" ENGINEERING ^ //3 FIRE Expedite? Y f N j '7/(<= Gr^ AFS Checked by ^-^ HazMat APCD Health If I'LIII Forms/Fees Sent Reed Due? By Enema Y N Fire i 1 Y N HaLWOllnAPCD Y N PE&M Y N School i 1 mm^ f -IT-Y N Sewer Y N Stormwater Y N Special Inspection Y N CFD y N LandUse Density ImpArea FY Annex Factor PFF Y N Comments Date Date Date Date Building (oMi3 Planning Engineering Fire Need? , • Done • Done • Done • Done • Done • Done