Loading...
HomeMy WebLinkAbout2100 COSTA DEL MAR RD; ; CB901680; Permit03-31-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Permit Permit No CB901680 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation OccGroup 2100 COSTA DEL MAR RD CBAD CTI Sub Type Lot # $0 00 Const Type NEW Reference # Project Title BAKERY FOR EXIST REST 1600 SF Statu Applied" Entered By Appr/Issued Inspect Area EXPIRED DC Applicant LA COSTA RESORT AND SPA Owner LA COSTA RESORT AND SPA 2100 COSTA DEL MAR RD CARLSBAD, CA 92009 619 438-9111 Total Fees $0 00 $348 00 Payments To Date $348 00 Balance Due Description Other Fee 348 00 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Or , Carlsbad, CA 92009 (BIS) «8-nei L PERMIT TYPE I ~A S3 COMMERCIAL QJNEW QTENANT IMPROVEMENT B D INDUSTRIAL D^EW QTENANT IMPROVEMENT c [^RESIDENTIAL DAPARTMENT QCONDO OSINGLE FAMILY DWELLING [^ADDITION/ALTERATION DDUPLEX DDEMOLITION QRELOCATION QMOBILE HOME OELECTRICAL QPLUMBING OMECHANICAL DpnOL DSPA ORETAINING WALL QSOLAR GOTHER_ PROJECT INFORMATION PLAN CHECK No EST VAL PLAN CK DEPOSIT VALID BY DATE 8890 10/39/90 0001 01 02 C-FKMT 348.00 FOR OFFICE USE ONLY Address 2100 Costa Del Mar Rd Nearest Cross Streets F"l BuiIdlng or Sulto No LEGAL DESCRIPTION Subdivision Name/Number CHECK BELOW IF SUBMITTED Q2 Energy Calcs C|2 Structural Calcs |~~1 2 Soils Report Addressed Envelope ASSESSOR S PARCEL 216-123-11 EXISTING USE el u bho u SB/ Res tau ran»C°p°SE° USE DESCRIPTION OF WORK Bakery for existing restaurant Estimated cost of construction $76,500 BLDG SO FTG # OF STORIES 3 CONTACT PERSON NAME Les Vaughn CITY Carlsbad, CA ADDRESS 2100 Costa Del Mar Rd ZIP CODE 92009 DAY TELEPHONE 438-7649 4 5 6 APPLICANT n CONTRACTOR Q AGENT FOR CONTRACTOR JHOUNER D AGENT FOR OWNERNAME La Costa Resort & Spa ADDRESS 2TuO Costa Del Mar Road C1TY Carlsbad, STATE CA Z.PCODE 92009 DAY TELEPHONE 438-9111 PROPERTY OWNERNAME Same as above CITY CONTRACTOR NAME CITY OWNER QLESSEE nTENANT ADDRESS STATE ZIP CODc DAY TELEPHONE ADDRESS STATE ZIP CODE DAY TELEPHONE STATE LIC #LICENSE CLASS CITY BUSINESS LIC * SIGNATURE DESIGNER NAME steven Langford Architects, WdESS 18218 E McDurmott, Suite "D" Irvine STATE r.A ZIP CODE Q?714 DAY TELEPHONE (714) WORKERS' COMPENSATION Workers' Compensation Declaration I hereby affirm that I have a certificate of consent to self insure issued by the Director of Industrial Relations or a certificate of Workers Compensation Insurance by an admitted insurer or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800 Lab C) INSURANCE COMPANY POLICY NO EXPIRATION DATE Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California SIGNATURE DATE 8 OWNER-BUILDER DECLARATION ~ Owner Builder Declaration I hereby affirm that 1 am exempt from the Contractor s License Low for the following reason [~~| 1 as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements arc not intended or offered for sale If however the building or improvement is sold within one year of complet on the owner builder will have the burden of proving that he did not build or improve for the purpose of sale ) [~1 I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) I am exempt under Section Business and Professions Code for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9 commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [S500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NOH RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act7 DYES DNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district"1 DYES DNO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? DYES ONO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097Ci} Civil Code) LENDER'S NAME LENDER S ADDRESS 10 APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct I agree to comply with all City ordinances and State laws relating to building construction 1 hereby authorize representatives of the City of Carlsoad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration Every permit issued by the Building Official under the provisions of this Code shall expir<? by limitation and become null and void if the building or work authorized by such permit is not coninenced within 180 days from the date of such permit or if the builduig or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of ISO days (Section 303(d) Uniform Building Code) APPLJtANVS SIGNATL OWNER CONTRACTOR BY PHONE APPROVED BY DATE WHITE File YELLOW Apph/ant PINK Finance DATE: 09/30/91 PLAN CHECK EXPIRATION PC# CB901680 DATE: 10/19/91 TO- LA COSTA RESORT AND SPA ADDRESS: 2100 COSTA DEL MAR RD 2100 COSTA DEL MAR ROAD CARLSBAD, CA 92009 You have applied to have your plans checked on the date shown above, and you have not obtained your building permit. The provisions of Section 304(d) of the Uniform Building Code state: "Section 304(d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." Please check the appropriate box indicating your choice and return this letter to the BUILDING DEPARTMENT. PROJECT ABANDONED. I WILL PICK UP PLANS WITHIN 10 DAYS. PROJECT ABANDONED. PLANS MAY BE DESTROYED. If you have any questions, please contact the Building Department at (619) 438-1161. DORIS COSMAN Building Department * *ESGIL CORPORATION 932O CHESAPEAKE DR , SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-I468 DATE' JURISDICTION _ PLAN CHECK NO- PROJECT ADDRESS PROJECT NAME C A /€ci> &AO SET 2,/QO TJT QAPP-LJ P A NT LJPLAN CHECKER QFILE COPYQUPS n DESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Z/OO CA Esgil staff did not advise the applicant contact person that plan check has been completed. 1 Esgil staff did advise applicant that the plan check has been completed. Person contacted Date contacted REMARKS . Telephone #_ By p Enclosures ESGIL CORPORATION cA DAA DRN ^ ,,/iu t JURISDICTION ^ '^•^ *—$. & S\o> Date plans received by plan checker li/ ? **/iu '•) PLAN CHECK NO *?0~/66o Date plan recheck completed /z /s By F" F PROJECT ADDRESS 2- IOO rt>STf> D g C *A< /g-D TO RECHECK PLAN CORRECTION SHEET FOREWORD PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access The plan check is based on regulations enforced by the Building Inspection Department You may have other corrections based on la\«s and ordinances enforced by the Planning Department, Engineering Department or other departments The items shown below need clarification, modification or change All items have to be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law © PLANS f 3 j The following items have not been resolved ^— from previous plan reviews The original Please make all corrections on the original correction number has been given for your tracings and submit two new sets of prints, reference In caso you did not keep—a copy and any original plan sets that may have been -ef—the—pr±e*—covi-ei.lluii list, W5—have returned to you by the jurisdiction, to -enclosed—those—pages—containing the otill outstanding-corrections- Please contact me if you have any questions regarding these items Please indicate here if any changes have been made to the plans that are not a result To facilitate rechecking, please identify, of corrections from this list If there are next to each item, the sheet of the plans other changes, please briefly describe them upon which each correction on this sheet has and where they are located on the plans been made and return this check sheet with the revised plans Have changes been made to the plans not resulting from this correction list9 Please check Yes No 71 OAJ ^i/t/vJ THAT i-j I Li. S> tr STbtf/rO Av£> f AC, (.1^6 /? I , I T)+j Ay Tl-hf £ xcttt? rn-f & /V& c/v'/v/Q D+rfr 6 fc /v £^<_/*H ( V 5 '/"UX-/3 € »£,. /5 ?*- A E- if <; $ xxl /i-A !\ rj /' /£^ (3 </y 5/flxo D OO^g * "j_ /£ A-O p ("flu^M £.C £ C7X i CA (.. A*,f> ^ f c HA Form No RPCS M290 , I JURISDICTION: ELECTRICAL PLAN CORRECTION SHKKT DATE:a FLAN CHECK NUMBER FLAN CHECKER: VOLUX WAGGONER HA* KEAL DARRELL HORRISON To speed up the recheck process,note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans V Submit complete electrical plans and specifications yf. Submit plan showing location of all services jf. Submit complete one-line diagram of service and feeders )S. Indicate the grounding system to be installed for building service lif. Indicate ampere interrupting capacities (AIC) of service and subservice equipment NEC 230-65/110-9 f>. Indicate sizes of fuses and/or circuit breakers Indicate fuse symbols to show fault currents are limited to 10,000 amps on branch circuits, i e JJN, LCL TO . s ..Jit. If fuses are not used to limit fault currents on branch circuits to 10,000 amps, specify method to be used J)'. Submit plan showing location of all switchboards ". Provide overcurrent protection on the secondary side of transformers NEC 240- 21/384-16(d) . Submit plan showing location of all panels }B. Submit panel schedules 16C Specify conduit and wire sizes . Specify aluminum or copper conductors and type of insulation ~. Show approximate length of feeders l Specify electrode conductor size and type wire (aluminum or copper) . Submit electrical load calculations . Indicate existing main service size ^ Indicate existing main service load- .. _. ' •• r " ". Indicate new additional loads23". ^ Indicate wiring method, i e EMT, metal flex }XS. Indicate dimension of switchboards and control panels rated 1200 amperes or more NEC 110-16(c) ^U'. Submit plan showing location of all transformers Indicate the grounding system to be installed for transformers NEC 250- 26(c) Any questions on electrical please contact the plan checker shown above, at Esgil Corporation at (619) 560-1468 Thank you . Show exit signs on the electrical lighting plan(s) As per Sec 3313 and 3314 of the 1988 UBC, provide two sources of power to exit signs and exit illumination Provide receptacle(s) within 25' of the HVAC A/C units UMC Section 509 2? Provide multiple switch lighting controls per CAC, Title 24, 2-5319 MECHANICAL, PLUMBING, ENERGY PLAN CORRECTION SHEET JURISDICTION // ' 3 & "" 9* O PLAN CHECK NUMEER )/^O 7-£+- DAZE _ ® GLEN ADAHEK PLAN CHECKER GARY ANGEL D C -2.Z ••• ^y. /?d"6) 3) Tree /O O 7" -o 71 POLICIES AND PROCEDURES NUMBER: 83-34 SUBJECT: GREASE TRAPS EFf-ECTIVE September 9, 1983 SECTION' BUILDING DEPARTMENT ^™v *0 SUPERSEDES: none PURPOSE BACKGROUND POLICY EXCEPTIONS To state the interceptors requirements of the City of Carlsbad for grease Waste pre-treatment is required An approved type grease interceptor shall be installed in the "aste line leading from sinks, drains, and other fixtures or equipment in restaurants and similar estabTishments wnere grease may be introduced into the sewer In all new construe' tion the interceptor shall be located outside the building When a project is being remodeled it may be impractical to install the interceptor outside Upon approval of the Building Official and the San Diego County Health Department it may be inside but shall be in an area other than the food preparation area and must be installed in the floor and be readily accessible The bottom of the grease trap must be sealed to the floor with an approved sealing compound The side walls and exterior must be smooth and cleanable An epoxy-type coating may be used to accomplish this 1 There are no onsite kitchen facilities such as ranges, steam cookers or dishwashing equipment 2 The restaurant has only warming equipment and all the service is on throw-away paper. 3 The Building Official and San Diego County Health Depart- ment approve elimination of the interceptor CITY ENGINEER UTILITIES DIRECTOR DIRECTOR OF BUILDING AND PLANNING ESGIL. r.nRPDR£I Initiated By: Martin Or enyak Approved By: City Manager ESGIL CORPORATION 9320 CHESAPEAKE DR , SUITE 208 SAN DIEGO, CA 92123 (619) 56O-1468 DATE' JURISDICTION _ PLAN CHECK NO PROJECT ADDRESS PROJECT NAME fo CARLSBAD SET fOO > rt FLO QAPPL_I£AN_ ]AN CHECKER]FILE COPY JUPS(DESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewitn is for your information The plans are being held at Esgil Corp. until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person The applicant's copy of the check list has been sent to 2.100 Cos TV* C.A/g.i.S g/q o |^| Esgil staff did not advise the applicant contact person that plan check has been completed II Esgil staff did advise applicant that the plan check has — been completed. Person contacted- Date contacted. REMARKS. Telephone #_ By:P Enclosures ESGIL CORPORATION IGA DAA Dvw U PLAN CORRECTION SHEET TENANT IMPROVEMENT FLAN CHECK NO. • JURISDICTION• CARLSBAD TO:L 6-K/y PROJECT DATA OCCUPANCY: BUILDING USE:7 TYPE OF CONSTRDCTION: ACTUAL AREA: ALLOWABLE AREA- STORIES: HEIGHT: SPRINKLERS OCCUPANT LOAD: REMARKS: Date plans received by jurisdiction Date plans received by Esgil Corporation Date initial plan check completed _ '<-/?/ By ? />3 C Applicant contact person Tel V3<S ?/// FOREWORD. PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped The plan check is based on regulations enforced by the Building Inspection Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Code sections cited are based on the 1988 UBC The circled items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e . plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans NOTE- PACK NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS HERE DELETED. LIST NO 56 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468 Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to The jurisdiction's building department Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans Section 302(d) Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code Provide the correct address and suite number of tenant space on the plans Section 302(d) Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled Section 302 When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy Please provide complete details to show the building with comply Section 502 UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed 10 ) Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building / On the first sheet of the plans indicate Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B A complete description of the activities andprocesses that will occur in this tenant spaceshould be provided A listing of all hazardous materials should be included The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible The building official may require a technical report to identify and develop methods of protection from hazardous materials Section 901(f) If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation Section 404 The number of control areas within a building used for retail/wholesale stores shall not exceed two, the number of control areas in buildings vith other uses shall not exceed four Footnote 1, Tables 9-A and 9-B The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage" Footnotes 2 and 3, Tables 9-A and 9-B Provide a statement on the Title Sheet of the plans that this project shall comply with Title 2k and 1988 UBC, UMC and UPC and 1987 NEC Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being unproved or altered Draw the plans to scale and indicate the scale on the plan Section 302(d) Indicate the use of all spaces adjacent to the area being remodeled or improved Show any existing fire rated area separation vails, occupancy separation walls, demising walls, shafts or rated corridors Identify and provide construction details for proposed new fire rated walls Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls OF J"S T>f).$OAJ 12/29/89 Identify existing walls to be removed, existing vails to remain and proposed new walls Identify bearing vails, non-bearing walls, and shear walls Provide a section view of all new interior partitions Show Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" Method of attaching top and bottom plates to structure (NOTE Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load) Wall sheathing material and details of attachment (size and spacing of fasteners) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing Provide notes and/or details to show that the floor and vail finish in toilet rooms are surfaced vith a smooth hard non-absorbent material extending five Similar surfacing shall walls from the floor to around urinals and vithin vater closet compartments Section 510(b) inches up the wall be provided on the a height of 4 feet Note on the plans "All interior finishes must comply vith Chapter 42 of the UBC" Specify "Class flame spread rating (minimum) for " Lateral bracing for suspended ceiling must be provided (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No 12 gauge wires secured to the main runner vithin 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling A strut (adequate to resist the vertical component from lateral loads) fastened to the main runner shall be extended to and fastened to the structural members of the roof or floor above These horizontal restraint points shall be placed 12 feet o c in both directions vith the first point within 6 feet of each wall Attachment of restraint wires to the structure above shall be adequate for the load imposed UBC Standard 47-18 In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s f and no horizontal dimension exceeds 60 L F (if space has sprinklers, then 3,000 s f and 100 L F ) Section 2516(f) In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s f and no horizontal dimension exceeds 60 L F (if space has sprinklers, then 9,000 s f and 100 L F ) Section 2516(f) Storage areas exceeding 1000 sq ft in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet Section 3802(c) The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled See the attached correction sheet Title 24, Part 2 The \»idth of the required level area on the side into vhich doors swing shall extend 2k inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors Section 2-3304, Title 24 Specify lever-type hardware for passage doors on floors accessible to the disabled Section 2-3304, Title 24 If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan Section 705 In areas where the occupant load exceeds , two exits are required See Table 33-A 0/w 2/15/90 Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size) CNC 5 —Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served Section 3303(c) The maximum number of required exits and their required separation must be maintained until egress is provided from the structure Section 3303(a) Rooms with more than 10 occupants may have one exit through one adjoining room Revise exits to comply Section 3303(e) Exit signs are required for exits serving an occupant load exceeding 49 Show all required exit sign locations Section 3314(a) Show that exits are lighted with at least one foot candle at floor level Section 3313(a) Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits Note on the plans "All exits are to be openable from inside without the use of a key or special knowledge" In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" This signage is only allowed at the main exit Section 3304(c) Exit doors should be a minimum size of 3 feet by 6 feet 8 inches v>ith a minimum door sv»ing of 90 degrees Maximum leaf width is 4 feet Section 3304(f) < . Q_0) f Exit doors should sving in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area Section 3303(b) Applies to door(s) _ Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access) Section 3304(i) Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position Section 3305(d) Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area Section 3304(h) Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock unless it is panic hardware Section 3318 Double acting doors are not allowed v>hen serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware Section 3304(b) Corridors must provide continuous protection to the exterior of the building Interruptions by an intervening room is not permitted Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms Section 3305 Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 4-4 inches v»ide and 7 feet high to the lowest projection Corridors serving less than 10 occupants must be a minimum of 36 inches in width Section 3305(b) When two exits are required, dead end corridors and exit balconies are limited to 20 feet Section 3305(e) Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction except a Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor Exterior sides balconies of exterior exit X f c Corridor vails and ceilings need not be of fire-resistive construction vithin office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance vith their listing Section 3305 (g) Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100 Section 3305(g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc ) 2/14/90 i Section 3305(g), Exception 5 is applicable only for corridors on one floor, the corridors on the lower level(s) must be rated if these lover corridors have openings into them from other levels If non-rated corridors are used per Section 3305(g), Exc 5, provide a reference to the corridors on the floor plan, noting f Corridors are non-rated per Section 3305(g), Exception 5 Smoke detection system must be listed by the State Fire Marshall and be a supervised low voltage system Smoke detectors center shall be maximum 30' on f U Power supply shall be dedicated branch circuit Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, vith a lock-on device If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall Clearly show vhere the non-rated corridor system terminates and a rated corridor system commences One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings in interior vails of exterior exit balconies Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b) Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 3305(h) Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor Such openings shall be protected by fixed, approved 1/4 inch thick wired glass installed in steel frames Section 3305(h) r / / Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, vails, ceiling and all penetrations Section 3305(g) Show the location of fire dampers Provide fire dampers at duct penetrations of fire- rated occupancy and area and corridor vails and A306(j) separations, shafts ceilings Section If a room vith an exhaust fan has a door opening into a rated corridor, show how make- up air vill be provided to the room The door cannot be undercut, nor can a louver in the door be provided Section 3305(h)l If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) vill be met Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision If a second door is provided at the elevator entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort Section 5106 Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment) When nonflammable supply cylinders for medical gas sjstems are located inside buildings, they shall be in a separate room or enclosure separated from the rest of the building by not less than one-hour fire-resistive construction Doors to the room or enclosure shall be self-closing smoke- and draft-control assemblies having a fire-protection rating of not less than one hour Rooms shall have at least one exterior vail in which there are not less than two vents of not less than 36 square inches in area One vent shall be within 6 inches of the floor and one shall be within 6 inches of the ceiling When an exterior v,all cannot be provided for the room, automatic sprinklers shall be installed vithin the room and the room shall be vented to the exterior through ducting contained vithin a one-hour" rated shaft enclosure Approved mechanical ventilation shall provide six air changes per hour for the room Section 702(b)A 6/13/90 83 81 Submit plan showing location of all panels Submit panels schedules Submit electrical load calculations Indicate existing main service size Indicate existing total main service load Indicate new additional loads Indicate wiring method, i e EMT, metal flex Show exit signs on the electrical lighting plan(s) As per Section 3313 and 3314 of the 1988 UBC, provide two sources of power to exit signs and exit illumination Provide receptacle(s) within 25' of the roof mounted A/C units UMC Section 509 Provide multiple switch lighting controls per Title 24, 2-5319 Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54 MECHANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant Section 605 and 705 v UBC Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment Detail access equipment and working clearances to HVAC Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged Section 1205, UMC One-hour corridors shall not be used as an integral part of a duct system This includes the space above a dropped ceiling within the one-hour corridor UMC Section 706(b) PUMBIHG Provide gas line plans and calculations, showing pipe lengths and gas demands UPC Section 1219 89t 9rf 7s Provide drain, waste and vent plans Provide water line sizing calculations UPC Section 1009 Detail how floor drain trap seal is to be maintained UPC Section 707 (floor drain trap priming) Show P & T valve on water heater and detail drain line route from P & T valve to the exterior UPC Section 1007(e) Show 1/4" per 12" slope on drain and waste lines UPC Section 407 Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments) UBC Section 605 ENERGY Provide complete energy design calculations, including all existing design and new energy design for this building See attached non- residential energy design checklist For remodels in an existing conditioned space, show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards CITY OF CARLSBAD SUPPLEMENT Floor drains Policy) must have auto-prime (City A grease interceptor is required Show details complying vith City Policy 83-34 Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6) Condensate drains must connect to a wet trap (dry traps are not permitted) (Memo 1/14/83) Show fans are duct type, City permit ductless fans Policy does not Romex is not permitted in industrial or commercial buildings (City Policy) No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official (City Policy) All panel boards shall have a minimum 100 amp rating or approved by the Building Official 4/6/90 The minimum rating of a service disconnect is 100 amperes The minimum size conductor to receptacles and lighting fixtures in commercial and industrial buildings shall be #12 Cu / AC(BX) cable is not allowed in group A, B, E, Hand I occupancies (see Ord for exception) HISCELLANEOOS Please see that follow additional corrections or remarks '108^ To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc (109 )Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list' Please check Yes No NOTE: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall They are provided here as a courtesy to assist designers in developing the project documents All applicable provisions may not necessarily be included Please direct any questions regarding interpretations of these provisions to the local Fire Department Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction Section 3305(g)l sA Where exit signs are required by Section 3314(a), approved and listed internally, externally or self-illuminated low-level exit signs complying with Section 3314 shall be required The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door Such signs shall be of a type which is perceptible to the sense of touch Section 3314(e) Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level Such marking shall be of a type which is perceptible to the sense of touch Section 3314(f) Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38 Section 505(e)6 EXCEPTION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection In educational occupancies, storage and janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating Section 802(c) Section 1807 should be reviewed for all high- rise buildings The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300 If emergency warning systems are required, they shall activate a means of warning the hearing impaired Flashing visual warnings shall have a frequency of not more than 60 flashes per minute The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468, to perform the plan check for your project If you have any questions regarding these plan check items, please contact at Esgil Corporation Thank you Enclosures 1 2 TTilL TVrf. of- coA/sr.zrc CtoC/fc^ t^ArtV AtC <N Pofs ~r>f-f_ fj f ^, tjj Ovf K -% H- fc. fc n^oofL. .IS Tt-t-i 2/28/90 &UlLa,,jf, 7 ^^r ,« n^ £0 /S S/ft>u,A/ 0-0 X>, A«< 1 AJ C A. ^ AS ^~ TH-f & Of i ^ rJ f- /^coC S^t-S- 4 O« U ) 1~ £ rJf-t~i t.^ rvr /t HAJ TYt-f €. A" 7~f </<i£_ df^ 7>*r£ - TTS i>f ^ •> ELECTRICAL PLAN CORRECTION SHEET JURISDICTION:., 10 PLAN CHECK NUMBER;~ /C SET X QVOLLLK WAGGONER PLAN CHECKER: Q RAY NEAL DARRELL HORRISON Submit complete electrical plans and specifications SL. Submit plan showing location of all services Submit complete one-line diagram of service and feeders b{ Indicate the grounding system to be installed for building serviceSIEC 2.50 - so ;e ico Indicate ampere interrupting capacities (AIC) of service and subservice equipment NEC 230-65/110-9 Indicate sizes of fuses and/or circuit breakers ©7. J Indicate fuse symbols to show fault currents are limited to 10,000 amps on branch circuits, i e JJN, LCL If fuses are not used to limit fault currents on branch circuits to 10,000 amps, specify method to be used a. Submit plan showing location of all switchboards 10. Indicate dimension of switchboards and control panels rated 1200 amperes or more NEC 110-16(c) ~\i.. I Submit plan showing location of all transformers U. Indicate the grounding system to be installed for transformers NEC 250- 26(c) "NEAREST 0& ELD& STEEL. PIPE ) IS. Provide overcurrent protection on the secondary side of transformers NEC 2AO- 21/38V-16(d) 14. Submit plan showing location of all panels 15. Submit panel schedules lo. Specify conduit and wire sizes I/. Specify aluminum or copper conductors and type of insulation llL Show approximate length of feeders l£. Specify electrode conductor size and type ' wire (aluminum or copper) . Submit electrical load calculations . Indicate existing main service size Indicate existing main service load. ^ \O OK "\K-b&\" 25. Indicate new additional loads "M, Indicate wiring method, i e EMT, metal ' flex 2o. Show exit signs on the electrical lighting plan(s) As per Sec 3313 and 331/t of the 1988 UBC. provide two sources of power to exit signs and exit illumination (26. ^Provide receptacle(s) within 25' of the A/C units UMC Section 509 f 2/.)Provide multiple switch lighting controls ^ — per CAC, Title 24, 2-5319 £ A Any questions on electrical please contact the plan checker shown above, at Esgil Corporation at (619) 5 MECHANICAL, PLUHBDIG, ENERGY FLAN CORRECTION SHEET JURISDICTION:DATE: FLAN CHECK NUMBER:.O ~ t & 3 o Bg GLEN ADAMEK FLAN CHECKER: GARY ANGEL D re. S 5 -'c»o / <•> ±3 MQUJ ^gS c* rt i? L^ /(JO J"L^o& bjuoiun§ Lte in bs c c c toto LI * 1to11 1 1 n 3 ^•O W•g w« o> tl .CVI U 0. Utl CM «a — ' 3« Uhi U3 °u -o3 eu «**^, » c o « a o19 Uu a.« Bit -^**< ueo> «e c -4 O •O t*s uc TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction Plan Check No 70- /6&o References to section numbers with prefix "2" are (California Building Code) Prefix Part 5 (California Plumbing Code) to Title Ik, California Code of Regulations, Part 2 3" is for Part 3 (California Electrical Code) Prefix "5" is for Exemptions claimed for any item shall be requested in writing and shall include all data needed to determine "unreasonable hardship" as described in Section 2-422 SITE DEVELOPMENT 1 HANDICAPPED PARKING SPACES Provide Jiandicapped spaces 2-7102(b) 3 Space shall be so located that handicapped persons are not compelled to wheel or v.alk behind parked cars other than his/her own 2-7102(c) c Parking space shall be a minimum of 9 ft x!8 ft vith adjacent marked 5 ft loading zone Double space shall be 23 ft vide Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle 2-7102(c) d Maximum slope of parking surface in any direction shall not exceed 1/4" per foot 2-7102(e) e Parking space(s) shall be identified vith the International Symbol of Accessibility on reflectorized sign affixed to post or vail, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the parking stall) 2-7102(f) f Entrance to parking area (or at each stall) shall have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-avay 2-7102(f)•% g Entrance to and vertical clearance within accessible level of parking structure shall be 8 ft 2 in to any structural member, duct or pipe 2-7102(g) CURB RAMPS a Curb ramps shall be located wherever pedestrian path crosses curb (2- 7103(a)) b Curb ramp shall be 48" mm. width (2- 7103(b)) with maximum slope of 1 in 12 2-7103(d) c A level 48" mm depth landing is required at top of curb ramps over entire curb ramp width 2-7103(d) d If no landing is provided, the slope of flared sides shall not exceed 1 in 12 2-7103(d) Surface is to be slip contrasting finish sidewalk 2-7103(f) resistant and a from adjacent f Border markings shall be 12" vide of l/4"xl/4" grooves, 3/4" apart, located at top and sides 2-7103(h) WALKS a Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc 2-7101(a) b Walks sloping greater than 5% (1 in 20) must comply \>ith ramp requirements of Sec 2-3307 2-3325(c) c Walk width shall be 48" minimum, and shall have slip-resistant surfaces 2-3325(a) d The maximum cross slope shall not exceed 1/4" per foot 2-3325(a)3 e Gratings are not allowed whenever possible 2-3325(b) f At each gate or door a 60"x60" level area is required when the gate swings toward the valk 2-3325(e) g A 48"x44" deep level area is required when the gate swings away from the valk 2-3325(e) h A 24" clear space is required at strike side of gate or door 2-3325(e) PEDESTRIAN RAMPS a A path of travel with a slope greater than 1 in 20 shall be considered a ramp 2-3307(a) b The maximum slope shall be 1 in 12 2-3307(c 1) c The width shall be 48" minimum A minimum vidth of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more Group R Occupancies may be 36" when the occupant load is 50 or less 2- 3307(b 1) d The surface of ramps shall be slip- resistant 2-3307(g) e A 60" intermediate landing is required at maximum elevation change of 30" and 72" landing at each change of direction (over 30 degrees) 2-3307 (d 1) f Landings are required at top and bottom of ramps 2-3307(d 1) g Bottom landing shall be minimum of 72" in the direction of travel Fig 2-33- 11A Top landing 2-3307(d 1) shall be 60" x 60" minimum When door swings minimum depth of door width plus 42" onto top landing, landing required is 2-3307 (d 1 ) j Top landing shall have 60" mm width when door swings onto the landing, with 24" on strike side of door at exterior ramp, or 18" at interior ramp 2-3307(d 1) k Ramp handrails are required on each side of ramp, when slope exceeds 1 in 15 2- 3307(e 1) 1 Ramp handrails shall be continuous, located 30"-34" in height above ramp surface, with 12" extensions beyond top and bottom, and the ends returned 2-3307(e 1) m Handrails shall be 1-1/4" to 2" cross section, spaced minimum of 1-1/2" from wall 2-3307 (e 1) n A 2" high curb or wheel guide rail centered 3" + 1" above ramp surface is required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length 2-3307(h 1) 5 SPECIAL ACCESS LIFTS a Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health 2-5107 (a) b The lift platform shall be of sufficient size to accommodate a wheelchair (30"x48") 2-5107(a) c. There shall be a level and clear floor area or landing (60"x60") at each level for access to the lift. 2-5107 (a) 6. HAZARDS a Provide 80" headroom from walkway surface to any overhanging obstruction 2-3326(b) b Headroom of 80" minimum shall be maintained for walks, corridors, aisles, etc 2-522(f) c Protruding objects with leading edges between 27" and 80" above finished floor shall not protrude more than 4" into walks, corridors, etc 2-522(f) d Free standing objects mounted on posts between 27" and 80" above the floor may project a maximum of 12" 2-522(f) e Abrupt changes in level exceeding 4" adjacent to walks, except between v.alks and adjacent streets or drives, shall be identified by 6" high warning curbs above walk surface 2-3326(a) ENTRANCES AND CIRCOLATIOW ENTRANCES, DOORS, VESTIBULES AND CORRIDORS a All primary entrances to buildings shall be accessible to the handicapped 2-3301(f) b All required passage doors shall have 32" clear opening at 90 degrees (36" door) 2-3304(f) c At least one of a pair of doors shall meet the minimum 32" clear entrance vidth requirement 2-3304(f) d Threshold shall be no higher than 1/2" above the floor Edge to be be\eled vith a slope no greater than 1 in 2, if more than 1/4" 3304(i 1) e Exterior level landing may slope up to 1/4" per foot in any direction for surface drainage 2-413 f Door hardware shall be of the lever or push type, mounted 30" to 44" above the floor and be operable vith a maximum effort of 8 5 Ibs for exterior doors and 5 Ibs for interior doors 2-3304(c), 2- 3304(i 2) g The lower 10" of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors 2-3304(i 3) h Building entrance(s) shall be identified by sign vith the International Symbol of Accessibility Show location on plan The symbol shall be a white figure on blue background 2-522(b) i At turnstile, provide an access gate, 32" clear width opening, within 30 feet of turnstile 2-3304(i 4) j. There shall be a clear area on each side of door, 60" deep in direction of door swing and 44" deep in opposite direction of door sving 2-3304(i 1) C/ST Width of clear area on the swing side of the door shall extend 24" past strike jamb for exterior doors and 18" past strike jamb for interior doors 2-3304(i 1) 1 The space between two consecutive doors (vestibule) shall provide a minimum of 48" clear depth between the open door and a second closed door Doors in a series at a vestibule shall swing in the same direction, or away from the space between them 2-3304(i 1) m For corridors over 200 feet long, see special requirements of Sec 2-3305(b)2 8 FLOORS a Floors of a given story shall be a common level throughout or shall be connected by pedestrian ramps, passenger elevators, or s pecial access lifts 2-522(e) STAIRWAYS NOTE: Only applies where disabled access is provided or required to other levels a Treaas shall have smooth, rounded evposed edges and be slip resistart 2- 3306(s) b Nosirg shall not project more than 1-1/2 inches past face of the r.ser below 2-3306(s) c Risers shall be sufficiently solid 2-3306(s) d The upper approach and lower tread of each flight of stairs shall be narked vith a contrasting colored strip 2" in vidth 2-3306(r) e On exterior stairs, each tread shall be marked as noted above 2-3306(r) f Handrails are required on each side of stairvay 2-3306 g Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread vidth beyond bottom nosing and returned to wall/newel post 2-3306(j 1) h Handrails shall be 1-1/4" to 2" in gripping cross section and 1-1/2" clear of wall 2-3306(j 1) i Approved stairway identification signs shall be located at each floor level in all enclosed stairways in buildings two or more stories in height The sign shall identify the stairway, indicate whether there is roof access, the floor level, and the upper and lower terminus of the stairway The information shall be presented using raised Arabic numerals and raised braille symbols which conform to Section 522(b)3 The sign shall be located approximately 5 feet above the floor landing immediately adjacent to the door on the strike side Signs shall comply vith requirements of U B C Standard No 33-2 10 ELEVATORS a Provide clear inside elevator car dimensions as required by U B C Section 5103(d) 6 and Title 24 2-5103(d 1) 1 At least one elevator in buildings 4 or more stories in height 80" by 54", with a 42-inch -side slide door Applies only to high-rise buildings, A/E/I occupancies, State-owned buildings, residential care homes, hotels, motels, apartments and condominiums 2 Elevator in buildings more than two stories or buildings where disabled access is required to uoper level(s) 68" by 54", v>ith a minimum clear door vidth of 36" 3 Elevators other than in (b) above serving less than 50 occupants shall have a mininum inside platfora of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door vidth of 36 inches b Raised Braille markings and Arabic numerals are required on control buttons and door jaabs 2-5103(d 1) SAKHARI FACTT.TTTES 11 TOILET FACILITIES ACCESS a When located on accessible floors, sanitary facilities shall be made accessible to physically handicapped (2-511 l(a)) b Doorways shall have 32" minimum clear opening vidth 2-511 1 c There shall be a level area vith 60" clear depth in the direction of the door swing, and a level area with 44" clear depth in opposite direction of door swing 2-511 l(a) 12 MULTIPLE ACCOMMODATION TOILET FACILITIES a Provide clear area 60" diameter x 27" high - or clear space 56" x 63" x 27" high 2-511 l(a) b Doors (other than handicap compartment) are not to encroach more than 12" into above mentioned clear space 2-511 l(a) c Provide a 28" clear space between v,ater closet and fixture or 32" clear space between water closet and vail 2-511 l(a) 16 URINALS A 48" long clear space is front of water closet space is required vhen compartment has a side door 2-511 l(a) required in A 60" clear the toilet e Water closet compartment door to provide 32" clear vidth for end entry and 34" clear vidth for side entry Door to be self-closing 2-511 l(a) 13 SINGLE ACCOMMODATION TOILET FACILITIES a Water closet shall be located 28" from a fixture or 32" from a wall 2-511 l(a) b Minimum clear space in front of vater closet shall be 48" 2-511 l(a) c In an existing building, a single accommodation toilet facility may have a space 36" wide x 48 " long in front of vater closet 2-511 l(a) 14 GRAB BARS AT WATER CLOSET a One at side 42" long extending 24" in front of vater closet, one at rear 36" long centered on vater closet, both mounted 33" above floor Where a tank- type toilet is used, grab bar may be as high as 36" 2-511 l(a) b Bars shall be 1-1/4" to 1-1/2" in diameter vith 1-1/2" clearance to vail 2-511 l(a) c Bar fasteners and mounting support shall be able to withstand 250 Ibs /ft in bending, shear and tension 2-511 l(a) 15 WATER CLOSET a Height of water closet seat shall be 17" to 19" above floor 5-1502 b Controls shall be operable with one hand, and shall not require tight grasping, pinching or twisting of the wrist 5-1502 c Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor 5-1502 d The force required to activate controls shall be no greater than 5 pounds force 5-1502 Where urinals are provided, the rim of at least one shall project 14" from the vail and be located 17" maximum above floor 5-1503(a) The force required to activate the flush valve shall be 5 Ibs maximum and located 44" maximum above floor 5-1503(b) Provide 30" x 48" forward approach clear floor space for 2-511 l(b) 17 LAVATORIES a Provide 30" x 48" clear floor space for forward approach Said clear floor space may include knee and toe space under lavatory described below 2-511 l(b) b Provide clear space beneath lavatories 29" high by 30" vide by 8" deep at top and 9" high by 30" wide by 17" deep at bottom from front of la\atory (toe space) The maximum counter surface height should be 34" 5-1504(a) Hot water and drain pipes lavatories shall be insulated 5-1504(b) under d Faucet controls and operating mechanism (operable vith one hand) shall be of the type not requiring tight grasping, pinching or twisting of the vnst (such as lever-operated) and an operating force not exceeding 5 Ibs 5-1504(c) e If self-closing valves are used, they shall remain open for at least 10 seconds 5-1504(c) 18 TOILET ROOM ACCESSORIES a Mirror bottom edge shall be located 40" maximum above floor 2-511 l(b) b Toilet tissue dispensers shall be mounted within 12" from the front edge of toilet seat 2-511 l(b) c Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc ) shall be within 40" of floor 2-511 l(b) 19 SANITARY FACILITIES IDENTIFICATION a On doorways leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" diameter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color Unisex facilities shall be identified by the circle with the triangle superimposed within the circle 2-511 l(a) Tl-hS 20 BATHING FACILITIES 24 PLUMBING REQUIREMENTS a One such facility shall comply vhen provided for the public, clients or employees 2-511 l(a) b Shower compartment shall be 42" wide, 48" deep, with a 36" wide entrance 2-511 l(a) c Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec 2-511a-9, 5-1505 and 5-1506, i e , folding seat, flexible shower hose, etc GENERAL KEOjUIKEHENXS 21 DRINKING FOUNTAIN a Drinking fountains shall be vithin alcoves The alcove shall be not less than 32" vide by 18" deep 2-511 l(c) b When the enforcing agency determines that it would create an unreasonable hardship to locate the vater fountain in an alcove, the water fountain may project into the path of travel, and the path of travel shall be identifiable to the blind as follows (1 ) The surface of the path of travel at the vater fountain shall be textured so that it is clearly identifiable by a blind person using a cane The minuuum textured area shall extend from the vail supporting the vater fountain to 1 foot beyond the front edge of the vater fountain and shall extend 1 foot beyond each side of the vater fountain, or (2 ) Wing vails shall be provided on each side of the water fountain The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the path of travel Also, there shall be a minimum of 32 inches clear between the wing walls c Note on the plans that drinking fountain shall conform to requirements of Sec. 2-511c and 5-1507 22 PUBLIC TELEPHONE a Provide space 30" x 48" for forward or parallel approach to telephone 2-511 l(d) b Note on the plans that public telephone shall conform to requirements of Sec 2-511 l(d) 23 ELECTRICAL REQUIREMENTS a 15, 20 and 30 amp receptacle outlets shall be installed not less than 12" above floor 3-210-50(e) b Center of switches shall be located not less than 36" nor more than 48" above the floor 3-380-8(c) a Where kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc , the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i e , use lever- operated, push-type, etc ) If self- closing valves are used, they shall remain open for at least 10 seconds 5-1508 GROUP A OCCUPANCY FEOJOIKEHEKTS 25 AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC a Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance 2-611(b) b This structure requires wheelchair seating spaces In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices 2-611(b) c Each wheelchair space shall be 60" x 30" and level 2-611(b) d When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location 2-611(b) e This structure requires seats for semi-ambulant persons Clear leg space shall be at least 2-611(b) 24" f Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible 2-611(b) 26 STADIUMS, GRANDSTANDS, BLEACHERS, PAVILIONS, GYMNASIUMS a This structure requires wheelchair seating spaces In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices 2-611(c) b When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location 2-611(c) c Ticket booths must be accessible from both sides 2-611(c) d Participation areas such as ball courts, exercise rooms, tracks, and clubrooms must be accessible 2-611(c) e Spectator and participant sanitary and locker facilities must conform to the requirements of Chapter 2-5 2-611(c) ?7 DINING, BANQUET AND BAR FACILITIES a Access shall be provided at primary entrances 2-611(d) b Wheelchair access shall be provided to all areas where each type of functional activity occurs 2-611(d) c This facility requires wheelchair seating spaces2-611(d) d At least one wheelchair seating space shall be provided for each dining, banquet and bar area 2-611(d) e Access to wheelchair seating spaces shall be provided by 36" minimum clear width main aisles 2-611(d) f Cafeteria line aisles shall be a minimum of 36" clear width 2-611(d) g Access to food preparation areas shall comply with provisions for entrance doors and doorways contained in Section 2-3304 2-611(d) h Restrooms and powder rooms shall conform to the requirements in Section 2-511 2-611(d) 28 RELIGIOUS FACILITIES a Sanctuary areas shall be accessible 2- wheelchair seatingProvide spaces in the sanctuary Use Section 2- 2-611(e) c Provide wheelchair access to raised platforms, choir rooms, choir lofts, performing areas and other similar areas. 2-611(e) d Assembly areas along vith enclosed and unenclosed platforms and stages shall be made accessible 2-611(e) e Sanitary facilities shall conform to the requirements of Chapter 2-5 2-611(e) 29. ASSISIIVE-LISTENING DEVICES a Assembly areas with permanently installed public address systems (other than exclusively for paging or background music), shall provide assistive- listening systems for people with hearing impairments 2-611(f ) b Since the capacity of the assembly area exceeds 99, this facility requires _ personal receivers to be available on request 2-611(f) c If the system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the performing area d A sign shall be posted in a prominent place indicating the availability of assistive-listening devices The sign shall include the international symbol of deafness and wording that states "Assistive-listening System Available" GROUP B OCCUPANCY. KEQOTREHEKTS 30 Group B occupancies used for assembly purposes but having an occupant load of lessthan 50 shall conform to all the requirements for Group A occupancies covered in Section 2-611 2-712(d) 31 SALES FACILITIES a General sales, display and office areas together with related toilet rooms must be accessible 2-712(b) b Sales employee work stations shall be located on accessible levels Employee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible 2-712(b) c This facility requires check stands accessible to the physically handicapped, based upon 1 for 8 checkstands or less, 2 for 9 or more 2- 712(b) d Where quick check stands are provided, at least one shall be accessible 2-712(b) e Check stands shall be made accessible by providing a 36" aisle on the customer side of the stand 2-712(b) f Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to be open at all times for handicapped/physically disabled customers" 2-712(b) 32 FITTING OR DRESSING ROOMS a Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the physically handicapped 2-712(b) b Minimum dimension of room shall be 60" x 60" 2-712(b) c Bottom of the mirror shall be located within 20" of the floor 2-712(b) d Height of clothing hooks shall not be greater than 48" from the floor 2-712(b) CSX/Of H OCCOPAHCf KBtyJIREKEKTS 33 a Accessible sanitation facilities in all Group H Occupancies shall be provided as specified in Chapter 2-5 2-913(a) b Accessible floors and levels shall comply with the requirements specified in Chapter 2-5 2-913(a) c Employee work areas shall be accessible by means of a 36-inch minimum aisle width, and a 32-inch minimum clear opening door width 2-913(a) ADDITIONS, ALXERAHOHS AKD REPAIRS TO EXISTING BUILDINGS. (Z-UOA(b)ll) The area of specific addition, alteration ^—•/ and/or repair, shall comply v.ith the provisions of Title Ik Additionally The primary entrance to the building and path of travel to the specific area shall be accessible to the handicapped persons Compliance must be shown, beginning from the existing parking area and leading to the area of alteration Existing restrooms, vater fountains, and public telephones which serve said specific area must be shown to be accessible to and functional for handicapped persons ( cJ Information regarding handicapped accessibility shall be posted in lobby per Sec 2-522 12/29/89 Date»Jurisdiction CARLSBAD Prepared byi /J P PLAN CHECK N0._ BUILDING ADDRESS APPLICANT/CONTACT BUILDING OCCUPANCY __ TYPE OF CONSTRUCTION VALUATION AND PLAN CHECK FEE COST/H n Bldg. Dept. D Esgil PHONE NO. DESIGNER PHONE CONTRACTOR PHONE BUILDING PORTION frAte-t-Y Air Conditioning Commercial Residential Res. or Comm. Fire Sprinklers Total Value BUILDING AREA VALUATION MULTIPLIER @ @ @ VALUE ?^S&0 -K 76 Soo Building Permit Fee $_ Plan Check Fee $$ 3 COM MEN TS;77 u SHEET OF 12/87 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE It fltft RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR « $10,000 00) PLAZA CAMINO REAL VILLAGE FAIRE OTHER COMPLETE OFFICE BUILDING PLANNER J.DATE //— /f- DATE ( fc C \WP51\FILES\BLDG FRM Rev 11/15/90 r/2560 ORION WAY CARLSBAD, CA 92008 Clt? Of F/fl£ DEPARTMENT PAGE 1 OF I ci-crnwiNt (619) 931 2121 PPO.IFCT AX) /7/X7-/3- MrfTtL^ AA Apr.HITFC.T *><h>i\f>*) / Atfc.£niZn HWNFR JA flfyZTA Rt-^r,/e>-r v v^/7/0 nr.oiiPAMnv ^ 1. CONST Q'SPRINKLERED (S TENANT IMP /T//v /- PLAN CHECK REPORT tsfjZi/ ADDRESS ^?//OrO fl CKTA /7<£^ > APPROVED , DISAPPROVED * PLAN CHECK# Q D " tte ¥(} l&e-L >W/?/€. ^D / -^/V- rv £J^yADDRESS ~T£G<A)Fs PHONE F^^ - Z/AL/H ADDRESS PHONE TOTAI SO FT STORIES rt ^7^ ' ^ APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS JL PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of floor plan(s), site plan, sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project Provide specifications for the following Permits are required for the installation of all fire protection systems (sj>rmk!ers>stand pipes,<drychemicaj.?halon, CO2, alarms, hydrants) Plan must be approved by the fire departmenrpTibr'fcTinstallation ^~~~" The business owner shall complete a building information letter and return it to the fire department FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required E'Automatic fire sprinklers (Design Criteria A"? 1v/ Dry Chemical, Halon, CO2 (Location L-b D Stand Pipes (Type '. D Fire Alarm (Type/Location Fire Extinguisher Requirements ^One 2A rated ABC extinguisher for each l_t /J5L r} sq ft or portion thereof with a travel distance to the nearest f "extinguisher not to exceed 75 feet of travel '/ ~ •' \ C^An extinguisher with a minimunrrratmg of £f-n n(> to be located // ) Xr / ftf frft ) D Other 8 Additional fire hydrant(s) shall be provided. EXITS _ 9 Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort .10 A sign stating, " This door to remain unlocked during business hours' shall be placed above the mam exit and doors .11 EXIT signs (6" x 3/4" letters) shall be placed over all required exiits and directional signs located as necessary to clearly indicate the location of exit doors GENERAL .12 Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code .13 Buildmg(s) not approved for high piled combustible stock Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids If high stock pil ing is to be done, comply with Uniform Fire Code, Article 81 .14 Additional Requirements .15 Comply with regulations on attached sheet(s) Plsr. Fyammor Report mailed to architect Met with Attach to Plans 2560 ORION WAY Of CARLSBAD, CA 92008 F/fl£ DEpARTMENT TELEPHONE (619) 931 2121 PLAN CHECK REPORT j PRn.iFfcT^4 fc&lA MoT(=L B/3£€^/ ARCHITECT ^>7E.\l£r)(.l LA.Aj&FoRb OWNFR//I (rfSrA /^S<^T 4 SfA OCCUPANCY 02- CONST WSPRINKLERED R/TENANTIMP /.SV<9 S<+' ADDRESs2/OO 'VlS/TA ADDRESS iD^V/M/e" ADDRESS TOTAL SO FT Pr /5/i/<rFi?v Dfcd A/ PAGE 1 OF / APPROVED _/ DISAPPROVED PLAN CHECK# /I AT /^f — j III PHONE S33-C/£>£^ PHONE STORIES " APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS PLANS, SPECIFICATIONS, AND PERMITS 1 Provide one copy of floor plan(s), site plan, sheets 2 Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project 3 Provide specifications for the following 4 Permits are required for the installation of all fire protection systems~(sprmklers^stand pipes,'dfy~chemical, halon, COz, alarms, hydrants) Plan must be approved by the fire departmenrp'rioTto'installation ^-^ " 5 The business owner shall complete a building information letter and return it to the fire department FIRE PROTECTION SYSTEMS AND EQUIPMENT 6 The following fire protection systems are required _ _ sE-Automatic fire sprinklers (Design Criteria , AS rEK Al+r-f\ I "^ ) Dry Chemical, Halon, COa (Location -j-i^AA / Q Stand Pipes (Type ) D Fire Alarm (Type/Location ) —i 7 Fire Extinguisher Requirements A "lil-One 2A rated ABC extinguisher for each bDOO sq ft or portion thereof with a travel distance to the nearest extinguisher not to exceed 7jjeet of travel ^ '' D/An extinguisher with a minimum rating of "7 O £> to be located /Af K;7( <Vrr'? / ' D Other 8 Additional fire hydrant(s) shall be provided . EXITS 9 Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort 10 A sign stating, " This door to remain unlocked during business hours" shall be placed above the mam exit and doors 11 EXIT signs (6" x 3A" letters) shall be placed over all required exits and directional signs located as necessary to j clearly indicate the location of exit doors ! GENERAL 12 Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code ; 13 Buildmg(s) not approved for high piled combustible stock Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or m racks and 6 feet for tires, plastics and some flammable liquids If high stock pil ing is to be done, comply with Uniform Fire Code, Article 81 14 Additional Requirements LES CA 15 Comply with regulations on attached sheet(s) . _ Da.e,Plan Examiner v _. - - — — - Report mailed to architect _ Met with -- ^ -- Attach to Plans City of Carlsbad Enaineerina Department Date /Q Z2 Chns Smith ENCINA WATER POLLUTION CONTROL FACILITIES 6200 Avemda Enemas Carlsbad, CA 92009 INDUSTRIAL WASTE PERMIT APPLICATION NO Enclosed is a copy of the application for an Industrial Waste Discharge Permit from the subject applicant Your review and recommendation on this application will be appreciated pnor to the issuance of a waste disposal permit LLOYD B HUBBS City Engineer LBH rz Enclosure Application No °\0 lie80 c Building Department Ernie Ferrer, Department of Public Works Arnie Wing, Department of Health Services 2O75 Las Palmas Drive • Carlsbad California 92OO9-4859 • (619)438-1161 COMMERCIAL/INDUSTRIAL APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT CITY OF CARLSBAD APPLICATION: NEW (CHECK ONE) REVISED BY L BUILDING P C NO APPLICATION NO INDUSTRIAL CLASS DATE- Iff 2.2. Signature of City Representative 05" APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT A. GENERAL• *PLICANT ADDRESS: YPE OF BUSINESS: PLICANT'S ADDRESS; 8. WASTES AND PROCESSING. (Check where applicable) Domestic Waste Only Industrial Waste Discharged to Sewer Industrial Waste NOT Discharged to Se*er GENERAL DESCRIPTION OF WASTE (Chemical and Physical Characteristics of proposed waste) • '__ rtb 2^*u GENERAL DESCRIPTION OF PROCESS (If Applicable) C. WASTES TO-BE DISCHARGED TO SEWER: WASTE- TREATED- (Check One) UNTREATED QUANTITY AVERAGE (Daily) MAXIMUM GPD GPD (Gallons Per Day) APPLICANT 08 REPRESENTATIVE OF FIRM ; /L./9 (Print) SIGNATURE :DATE I ^_d oo n Big m m m 1 C ,00 D CD 13 1 2 £> 3 =| 5" «=_ S « <S a 5 — CQ