Loading...
HomeMy WebLinkAbout2101 COSTA DEL MAR RD; ; CB021226; Permit05-24-2002 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Miscellaneous Permit Permit No CB021226 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Droject Title 2101 COSTA DEL MAR RD CBAD MISC 2152101800 $10,00000 Subtype OTHER Lot# 0 LA COSTA RESORT INFILL OF SLAB @ CLUBHOUSE Applicant i OSCANO ARMANDO 1909 STATE ST Status ISSUED Applied 04/23/2002 Entered By MDP Plan Approved 05/24/2002 Issued 05/24/2002 Inspect Area Owner K S L LA COSTA RESORT CORP 50-905 AVENIDA BERMUDA 792705/24/02000201 02 LA QUINTA CA 92253 CGP l64°49 Total Fees $16449 Total Payments To Date $000 Balance Due $16449 Miscelaneous Fee #1 Miscelaneous Fee #2 Additional Fees TOTAL PERMIT FEES PLAN CHECK PERMIT $6480 $9969 $000 $16449 Inspector FINAL APPROVAL Date /""'/ 0 7-Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATI'ON CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1 PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By Date f Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use Proposed Use Description of Work SQ FT #of Stories # of Bedrooms # of Bathrooms CONTACT PERSON (if different from applicant) ..:..jni, Nfo ~tt>ssanfi /<?£><?/"/ SGhA'eaa f/f. 6/7-23'?- Name Address City 3 APPLICANT -ED Contractor 7 D Agent for Contractor "M^L3 Owner Q;Agent for Owner (7 Strffe/Zip Telephone #Fax # Name '4 PROPERTY OWNER Address City State/Zip Telephone Name Address City State/Zip Telephone # : CONTRACTOR COMPANY NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # 6 WORKERS' COMPENSATION - , ,..^Z '"' -m " -• ib. -*"!" i:- '*• - "' - Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~l I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued l~l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE 7 OWNER BUILDER DECLARATION , '"h tiKi :h tj! I hereby affirm that I am exempt from the Contractor s License Law for the following reason l~l I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) IJ^f I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) d I am exempt under Section Business and Professions Code for this reason I personally plan to provide the major labor and materials for construction of the proposed property improvement d YES I (have //fiave notpsigned an application for a building permit for the proposed work 3 I have corftracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) f /J—A,/ . 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) rf , * /? S DATE of wo PROPERTY OWNER SIGNATURE COMPLETE THIS SECTION FOR NON OfSffi^fflAL BUILDING PERMITS ONLY Is the applicant or future building /(ecuparft required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? d YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' d YES d NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? d YES d NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT a 'CONSTRUCTION LENDIN^AGENCY , iim i I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS 1 APPLICANT CERTIFICATION " i :: i:; ,: j i;i; I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commencedjor a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE^^^^I^g-g^^^? DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Bldg Inspection Request For 06/28/2002 Permit# CB021226 Title LA COSTA RESORT Description INFILL OF SLAB @ CLUBHOUSE Inspector Assignment PD 2101 COSTA DEL MAR RD Lot 0 Type MISC Sub Type OTHER Job Address Suite Location APPLICANT TOSCANO ARMANDO Owner K S L LA COSTA RESORT CORP Remarks Phone 6198438296 Inspector Total Time CD Description 19 Final Structural Act Comments Requested By MIKE Entered By CHRISTINE Associated PCRs Inspection History Date Description Act Insp Comments 06/24/2002 11 Ftg/Foundation/Piers AP PD EsGil Corporation In !Partnersfi.ip With government for "Building Safety DATE May 21, 20O2 a AERUCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 02-1226 SET II PROJECT ADDRESS 21O1 Costa del Mar Rd PROJECT NAME La Costa Resort Infill Slab at Floor (Fitness Center) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes 1X1 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed | Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person X] REMARKS On the cover sheet, indicate that special inspection is required for the 4000 psi concrete, too By Kurt Culver Enclosures Esgil Corporation D GA D MB D EJ D PC 5/16/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership With government for Quitting Safety DATE May 3, 2002 Q APPLICANT JURISDICTION Carlsbad a~TLANREVlEWER a FILE PLAN CHECK NO 02-1226 SET I PROJECT ADDRESS 2101 Costa del Mar Rd PROJECT NAME La Costa Resort Infill Slab at Floor (Fitness Center) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XJ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XJ The applicant's copy of the check list has been sent to McCabe Harris Inc 1909 State St San Diego, CA 92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Armando Toscano (/^") Telephone # (619) 233-8740 Date contacted 5-&-oz- (by ) Fax # -8741 Mail v Telephone-^ Fax«-^ In Person REMARKS By Kurt Culver Enclosures Esgil Corporation D GA D MB D EJ D PC 4/29/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad 02-1226 May 3, 2002 GENERAL PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO O2-1226 PROJECT ADDRESS 2101 Costa del Mar Rd DATE PLAN RECEIVED BY DATE REVIEW COMPLETED ESGIL CORPORATION 4/29/02 May 3, 2002 REVIEWED BY Kurt Culver FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law • Please make all corrections on the original tracings and submit two new complete sets of prints to ESGIL CORPORATION • To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? Q Yes a No Carlsbad 02-1226 May 3, 2002 1 Please justify the occupancy/Type of Construction shown on the Title Sheet of the plans Please check with official city records If the use is a fitness center, this may be an A-3 occupancy Additionally, since the fitness center abuts the main clubhouse, it should have the same Type of Construction (unlikely to be V-N) 2 Each sheet of the plans must be signed/sealed by the licensed designer responsible for the preparation 3 Please justify the live load reported on the Title Sheet For a fitness center, 50 psf appears to be too low 4 Please specify on the plans that special inspection will be required for the epoxy anchors shown on sheet S1 1 5 Please provide complete structural materials specifications 6 Please provide structural calculations a) Provide design for the selected rebar b) Provide design to justify the existing members that will be supporting the new loads i) The existing slab n) The existing beams in) The existing columns iv) The existing foundation 7 Provide dimensions on the plans to show the size of the infill opening 8 Please justify removing a stair A complete exit plan must be submitted to justify this 9 Please provide a construction cost estimate 10 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Kurt Culver at Esgil Corporation Thank you Carlsbad 02-1226 May 3, 2002 JURISDICTION Carlsbad VALUATION AND PLAN CHECK FEE PLAN CHECK NO 02-1226 PREPARED BY Kurt Culver DATE May 3, 2002 BUILDING ADDRESS 2101 Costa del Mar Rd BUILDING OCCUPANCY B TYPE OF CONSTRUCTION V-N BUILDING PORTION Floor Infill Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb RIHn Pprmrf- Foo h\/ HrHinanro » 1 Valuation Multiplier By Ordinance Reg Mod VALUE ($) 10,000 10,000 $99 69 | Plan Check Fee by Ordinance jrj Type of Review [J Repetitive Fee Repeats 0 Complete Review D Other Hourly D Structural Only O Hour Esgil Plan Review Fee Comments $64 80 $5583 Sheet 1 of 1 macvalue doc B5/23/2002 12 30 2338741 MCCABE HARRIS PAGE 02 IM IHU iu Id fin 1,11Y Ur UflKbLBfli) FfiX NO (U1 6C2 8558 P 03 City of Carlsbad B n SI d i n q D e p a r t m e n t BUILDING DEPARTMENT NOTJfiE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Finn Check No ftf-" Job Address or Legal Description 2/OOPAtJn 3W '/MA* '_£D (? Owner KSL LA(Wa. "Res***/ &i*i Address £/Q<? &&& Oe/ You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector i«? required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by i Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) 1635 Faraday Avenue • Carlsbad CA 92008-7314 • (76O) 6O2-2700 • FAX (760) 6O2-6B6O Building Counter • (76O) 6O2-2719 • FAX (760) RO2-8558 10 2338741 Inl l\0 14 AM CITY OF CflRSLBflD MCCABE HARRIS ____ FAX NO 780 BC2 8B58 03, P 04 SPECIAL INSPECTION PROGRAM ADDRESS OR LIQAL DESCRIPTION £~to( Co^k- PUN CHECK NUMBER: /•&* Wf* QWMgtt'fi NAME* I, as the owner, or agent ef the owner (contractors meyjnpj employ (ha special inspector) certify that I, or the irehitectenglneer of *ttcord, will be rsspenslbla for employing) the special inspectors) as raqglraef by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the «fte IFited above UBC Section 106 3 5 Signed, \, as the engineer/architect of record, certify that I have prepared the following apodal Inspection program ae required by UBC Section 106.3.5 for the construction projnet located at the site listedj 1 Lltt of work requiring epeclel Inspection- , Soil* Comptfanee Prior to Foundation Inspection Structural Generate Over 2600 PSI Pr»atress«d Concrete Structural Masonry Designer Specified Q Field Weldlnl D High Strength Q Kxpanelon/Cpoxy Anchor* Q Sprayed*On FlreproDflng D Other $to*v f.y.w 2 Nama(3) of Indlvldual(e) or flirm(a) retponalble for the special Inspections listed above* B d 0 tf C 3 Duties of the epeelal Inspectors tor the work listed above; A a c Special InnMtrtore «Mll ehaek In wltn thi Cfty end pwe«n« Vrelr eradentKilR for approval caajft beg^nlno vwrtc tin #a |ob alte SIP 4907 CARL SCHMIDT REGISTERED SPECWL INSPECTOR PO Box 178403 V Son Diego. CA 92177-8403 \ Phone (619) 855-9252 \ SPECIAL INSPECTION REPORT / c, Cfs5^ 7?/ro/^ JOB START 2_ ADDRESS O.lol £arl<* #/ ^r <fd JOB STOP CITY /"^, i.f bJ PERMIT # C ft'Oil 1.1 C PLAN FILE # TYPE OF OBSERVATIONS' MASONRY REINFORCED CONCRETED. FIELD WELDING EPOXY PRESTRESSED CONCRETE SHOP WELDING BOLTING REINFORCING STEEL FIREPROOFING. SAMPLES NUMBER J^y TYPE MotenatyDesign Mix Numbere/PSI /?/^ " ' ' ^-f- Inspection Date fa~ ?& °^ REPORT . t/ i ,__/ f 11 <.'* 5 r\ ' C\f » ' rJ'J f • * ' -J H " WORK INSPECTED CONFORMS WTTH APPROVED PLANS AND SPECIFICATIONS UNLESS OTHERWISE NOTED : Project Billing Information Print Name Certification# Phone ( ). Fax ( ) Signature of Special Inspector Carl Schmidt Inspection P O Box 178403 San Diego. CA 92177-8403 Phone (61.9) 855-9252 PROJECT ADDRESS CfTY SPECIAL INSPECTION REPORT r />fc/, c; </PERMIT #£> Z / 2 JOB START JOB STOP PLAN FILE # TYPE OF OBSERVATIONS MASONRY REINFORCED CONCRETE FIELD WELDING EPOXY_J<L PRESTRESSED CONCRETE SHOP WELDING BOLTING REINFORCING STEEL FIREPROOFING. SAMPLES NUMBER TYPE Materials/Design Mix Numbers/PSI Inspection Date REPORT /J To _, Z 8 "* /?// <y i^i , WORK INSPECTED CONFORMS WTTH APPROVED PLANS AND SPECIFICATIONS UNLESS OTHERWISE NOTED r / J c-Project Billing Information Print Name Certification^c » 7" Phone Fax 2ZJ- inspector's Signature KLEINFELDER Report No Q 5015 Shoreham Place San Diego CA 92122 Last Reissued on Report TO Carl Schmidt Carl Schmidt Inspection Services , PO Box 178403 San Diego, CA92177 Supplier Hanson Aggregates MIX No 4033000 Design Strength 4000 psi @ 28 days Mix Data Date Sampled Source of Sample 6/26/02 In fill slab at Club Mouse Date Received Sample Data 6/27/02 Project No 18781 Ref No Project La Costa Resort Club House San Diego &IOI Cogk. A/fa, Phase n/a Permit No Observed by Klemfelder Cement Type Cement Factor (sk/cy) 6 7 Max Size Agg (in ) 1 Admixtures Observed by Klemfelder Contractor Truck/Ticket Sampled By Submitted By Curing Method Specimen Prep Field Cure Temp (°F) Hi Field Cure Time 24±4 337767 Carl Schmidt Carl Schmidt Cure Room Sulfur Lo Weather Wind (MPH) Rh (%) Slumpfin ) Slump w/plasticizer(m ) Air Temperature (°F) Mix Temperature (°F) Air Content (%) Unit Weight (pcf) Batch Size (cy) Water Added (gal) Time Batched Time Sampled 1015 Measured 40 Specified Time in Truck Laboratory Data Sample Number 11207 A 11207 B 11207 C 1120V L) Date Tested /78/02 7/24/02 //24/02 Age (days) 12 28 28 0 Dimensions Diam Ht Len 6 X 12 x 6 X 12 X 6 X 12 X b X 12 X Area (in') 2827 28 2/ 2827 2827 Ultimate Load (Ibs) 9//90 119/40 11/830 Compressive Strength (psi) 3460 4230 41/0 Required Strength (psi) 4000 4000 4000 4000 Average 28 Day Strength (psi) All fractures were conical in nature unless noted otherwise Remarks ^ 0* C^Jt Reviewed by Linda Hodo Concrete Lab Asst Unless prior arrangements have been made all HOLD specimens will be discarded if required strength is attained As a mutual protection to our clients and ourselves all reports submitted are the confidential property of our clients and authorization for publication of statements conclusions or extracts fromour reports are reserved pending our written approval CARL SCHMIDT REGISTERED SPECIAL INSPECTOR P O Box 1 78403 San Diego. CA 921 77-8403 Phone (6 19) 855-9252 SPECIAL INSPECTION REPORT PROJECT j£i£=£&skt==&£&s "/" _ JOB START f ADDRESS 3 lol ^.A-k tXl /n^ JJ _ JOB STOP CITY /^or/r LJ _ PERMIT # £/f O 2-t "2.-Z C PLAN FILE # TYPE OF OBSERVATIONS MASONRY REINFORCED CONCRETED FIELD WELDING EPOXY PRESTRESSED CONCRETE SHOP WELDING BOLTING REINFORCING STEEL FIREPROOFING. SAMPLES NUMBER _J[y TYPE _ MatenalsOesign Mix Numbers/PSI /2/n C*****^. >«<± faJJ*&' 4. Inspection Date - ?b ^ REPORT . i I t 7 '' 4 //vMJ / ± - ' J (f) L> ~ £ ^ f"*' WORK INSPECTED CONFORMS WITH APPROVED PLANS AND SPECIFICATIONS UNLESS OTHERWISE NOTED ~cf Project Billing Information Print Name Certification^ Phone Fax( Signature of Special Inspector Carl Schmidt Inspection P O Box 1 78403 San Diego. CA 92 17 7-8403 Phone (6 19) 855-9252 v SPECIAL INSPECTION REPORT PROJECT ADDRESS CITY / C?c3j /yfc/, c/PERMIT #0 2. / 2 Z £ JOB START JOB STOP PLAN FILE # %:oo TYPE OF OBSERVATIONS' MASONRY _ REINFORCED CONCRETE _ FIELD WELDING _ PRESTRESSED CONCRETE _ SHOP WELDING _ BOLTING _ REINFORCING STEEL _ FIREPROOFING SAMPLES NUMBER TYPE Materials/Design Mix Numbers/PSI inspection Date REPORT .5" // Z 3 7"- </ WORK INSPECTED CONFORMS WfTH APPROVED PLANS AND SPECIFICATIONS UNLESS OTHERWISE NOTED C^UV Jc JtZ?Print Name Certification# Phone Fax(2ZJ- Inspector's Signature LA COSTA RESORT CLUBHOUSE SXAIRWAY INFILL SLAB BUILDING INFORMATION Project Summary Assessor's Parrel Numhor TS TITLE SHEET 216-123-03,04,05 Legal Description. Those portions of section 26 and 35 in township 12 South, range 4 West, San Bernardino Meridian, in the County of San Diego, State of California, according to offical play thereof Building Code. 1998 California Building Code which adopts 1997 UBC, UMC, UPC and 1996 NEC Fire Protection. Fully Sprmklered I Construction, Type II, 1 Hour—^**_—Seismic Zone. 4 (no near source factor concern) VICINITY MAP COSTA SITE A1 1 SITE PLAN A2 1 PARTIAL FLOOR PLAN GENERAL NOTES SPECIAL INSPECTION IS REQUIRED FOR THE EPOXY ANCHORS SHOWN ON SHEET SI 1 S1 2 STRUCTURAL CALCULATIONS ""*—<^--s_-— —-^— CONSULTANTS OWNER La Costa Resort & Spa 2101 Costa Del Mar Road Carlsbad, CA 92009 Tel (760)438-9111 Fax (760)931-7557 Jeff Roberson email jroberson@lacosta com ARCHITECT McCabe Hams Incorporated 1909 State Street San Diego, CA 92101 Tel (619)223-8740 Fax (619)223-8741 Tom McCabe, AIA x email tmccabe@mh4jrch Jeff Davis email jdavis@mh-ar Armando Toscanox> ^r\ email atoscano@mh-arch coiS^ STRUCTURAL ENGINEERS Flores, Lund Consultants 7220 Trade Street, Suite 120 San Diego, CA 92121 Tel (858) 566-0626 Fax (858)566-0627 Michael, A McNeff, P E GENERAL CONTRACTOR R.D Olson Construction 2955 Mam Street, 3rd Floor Irvine, CA 92614 Tel (949)474-2001 Fax (949)474-1534 Walter Shirley email wshirley@rdolson com Matt Grubb email mgrubb@rdolson com TITLE SHEET TS LA COSTA RESORT CLUBHOUSE STAIRWAY INFILL SLAB AREA OFWORK A217A OURTYARD BbULDING SITE PLAN SCALE 1" - 250'-0" LA COSTA RESORT CLUBHOUSE STAIRWAY INFILL SLAB 7 1 Hf~~y^ ENTRANCE RAMP - PROPOSED SLAB INFILL OPEN SPACE D MAIN ENTRANCE PARTIAL FLOOR PLAN SCALE 1/16" - 1'-0"A21 LA COSTA RESORT CLUBHOUSE STAIRWAY INFILL SLAB HC ENTRANCE RAMP MAIN ENTRANCE EXIT PLAN SCALE 1/16" - I'-O"EX1 FLC FlORES LUND CONSULTANTS .™ 00030 PROFESSIONAL ENGINEERS 7220 Trade Street Suite 120 SAN DIEGO CALIFORNIA 92121 2325 (858) 566-Q626 FAX (858) 566-0627 SHEET NO .OF CALCULATED BY. CHECKED BY SCALE \A DATE. DATE. 4 2. 0Z-. PSOOUCT 2(H 1 iSincl! ShfKI ?ni I IP 1,1 HI SENT BY FLORES LUND CONSULTANTS,956 565 0627,MAY 15 02 2 32PM,PAGE 3/3 FLC JOB FLOPES LUMP OOMBULTANTS ; PROFESSIONAL ENGINEERS 792O Trade Street Suite 133 d«l\i DifcijC CrtLiruFirMiA 98121 23E5 (658) 566-06BB FAX tBSB) 56b-U627 dHEET NO . CALCULATED BY- UHfcOKED BY DATE. DATE. (3"") AT LU + II 65 I* nt 15 6 Lj\l& S-LA& ML I**** am !-' 041 in rtte^ - 10 ( iv O.H 1 0 4 ;sf\ I/1 e r-^ IpSS08 O o oCOO o O O 73mm > "'2 *®j,2 no H o r2 V> CCD O (S)m om O Ogo to to- lI