HomeMy WebLinkAbout2101 COSTA DEL MAR RD; ; CB030549; Permit04-22-2003
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
\
CB030549
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
Applicant
TOM MC CABE
1909 STATE ST 92101
619233-8740
2101 COSTA DEL MAR RD CBAD
Tl Sub Type COMM
2152101800 Lot# 0
$27 840 00 Construction Type NEW
Rsf0rsnc6 $LA COSTA SPA-CHOPRA CENTER928 SF REMODEL GUEST ROOM/WORK ROOM
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Plan Check#
Owner
K S L LA COSTA RESORT CORP
50-905 AVENIDA BERMUDA
LA QUINTA CA 92253
ISSUED
02/26/2003
RMA
04/21/2003
04/21/2003
3333 04/22/03 0002 01 Q2
CGP 488.:%
Building Permit
Add'l Building Permit Fee
Plan Check
Add I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add I Pot Water Con Fee
Reel Water Con Fee
$231 87 Meter Size
$0 00 Add I Reel Water Con Fee
$15072 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$585 PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$41 00
$3500
$2400
$000
$000
$000
$000
$488 44
Total Fees $488 44 Total Payments To Date $000 Balance Due $488 44
Inspector
FINALAPPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and We the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
'PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO (1^03 f) 5 ^<3
9.7.EST VAL
Ck Deposit
Validated By^.
Date X?
% 10 \cosrA BBsoert&PA
Address (include Bldg/Suite #)
cFSecnerAZfeAiJO'56
Business Name (at this address)
(2. SOUTH,
Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor s Parcel #Existing Use Proposed Use
2-
SQ FT.Description of Work
£tuESr£aei»<g&
,-,.
-STATE. -sne
#of Stories Bedrooms # of Bathrooms
CA/f 2.101
Address City
orQwnaf
State/Zip Telephone # Pax t
Name Address City
?t^^^Ei^qypgR^?^f •• "M-i^r.; -J", y-'^v '• "
LA C&T* eesogr 4 ^>fa -ZJQQ COSTA PE<. H4<e.go gAet.sa.Ai?
State/Zip Telephone
State/Zip Telephone #Name Address City
I^ffinFf' fr *€»£
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its
issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
(Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001)
Name
State License #
Address
License Class
City State/Zip
City Business License #
Telephone #
Designer Name
State License #
Address City State/Zip Telephone
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
l~l I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance
of the work for which this permit is issued
l~l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is
issued My worker s compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED !F THE DERM!T IS FOR ONF HUNDRED DOLLARS 1*1001 OR LESS)
I~| C'"~ - SAT 3 I.--;: VHC>» i i-er ny nut i- me parioimance or tne worn ror wnich this permit is issued I snail not employ any person in any manr.ei so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees
SIGNATURE . DATE
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
D I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is
sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
(H*. I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The
Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
D I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES flNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / typebut
/
PROPERTY OWNER SIGNATURE
Is the applicant or future buildiTTgoccupant required to submit a business plan acutely hazardous materials registration foan or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? O YES 0* NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? n YES jfi* NO
Is the facility to be constructed withm 1 000 feet of the outer boundary of a school site? l~| YES "OT NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
Pliapi^W^ ••', '•;"•••• v-,:* •• '• ':"": - " -L '•.'.-
I hereby affirm that there is a construction lending agency for the performance of the work fo which this permit is issued (Sec 30970) Civil Code)
LENDER S NAME _ LENDER S ADDRESS __
'••,•••••<'- , • ;"«;.si ,&••.*:..,.•• ••"••",%• '<.' •' •' '•: : •;>?•''fs.'.-irr'^-Ftzw'jf- ••,•?-» .:»K?:.rr.~ *•»;••-*' :fe•' jijfiii..- >>•*•-' *ft? ^'¥ ' ;»i"
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stones in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit ts not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenpeiS«f*a<Qau2d*tiilQ^«w4Section i(te 4 4 Uniform Building Code)
J*fe-UM». „ /fOk.. f_j^aU . 1~
APPLICANT S SIGNATURE.DATE
YELLOW Applicant PINK Finance
City of Carlsbad
Final Building Inspection
Dept Building Engineering Planning CMWD St Lite Fire''
Plan Check #
Permit #
Project Name
Address
Contact Person
Sewer Dist
Inspected,
Inspected
Bv
Inspected
Bv
Comments
Date 06/26/2003
CB030549 Permit Type Tl
LA COSTA SPA CHOPRA CENTER Sub Type COMM
928 SF REMODEL GUEST ROOM/WORK ROOM
2101 COSTA DEL MAR RD Lot 0
YOHAN Phone 9492464503
LC Water Dist CA
/rf Date 7/<X/ -7 -^^
'^—-^ft^-^' Inspected /^/^^ Approved Disapproved
(/Date
Inspected Approved Disapproved
Date
Inspected Approved Disapproved
City of Carlsbad Bldg Inspection Request
For 06/26/2003
Permit* CB030549
Title LA COSTA SPA-CHOPRA CENTER
Description 928 SF REMODEL GUEST ROOM/WORK ROOM
Inspector Assignment PD
Sub Type COMM
2101 COSTA DEL MAR RD
Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT TOMMCCABE
Owner K S L LA COSTA RESORT CORP
Remarks
Phone 9492
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By YOHAN
Entered By CHRISTINE
;t „ Comment
CV020692
PCR02289 ISSUED
PCR03017 ISSUED
PCR03059 ISSUED
PCR03073 ISSUED
Associated PCRs/CVs
CLOSED H MOLD AND ILLEGAL CONST (ROOF
LA COSTA RESORT/MOVED WALLS & REVISE LIGHTING @ CLUBHOUSE FITNESS
LA COSTA RESORT REVISE ELECTRICAL PLANS
LA COSTA RESORT REV LOCKER RM PLANS PHS 1 TO LEAVE HVAC AS IS
LA COSTA RESORT& SPA MOVING WALLS
Inspection History
Date Description Act Insp Comments
05/15/2003 14 Frame/Steel/Bolting/Weldmg AP PD
05/15/2003
05/06/2003
17 Interior Lath/Drywall
84 Rough Combo
AP
AP
PD
PD
EsGil Corporation
In (Partnership with government for (Buifdmg Safety
DATE 4/16/O3 O l
,O JURIJ
JURISDICTION City of Carlsbad 0~PtAN REVIEWER
U FILE
PLAN CHECK NO 03-549 SET III
PROJECT ADDRESS 21O1 Costa Del Mar Rd
PROJECT NAME La Costa Resort and Spa Chorpa Center- Treatment Rooms
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
[Xj Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 4/8/03 trnsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 *• (858)560-1468 + Fax (858) 560-1576
EsGil Corporation
In Partners/tip wit/i government for (Building Safety
DATE 3/31/O3 Q APELJCANT
JURISDICTION City of Carlsbad
PLAN CHECK NO 03-549 SET II
PROJECT ADDRESS 2101 Costa Del Mar Rd
PROJECT NAME La Costa Resort and Spa Chopra Center - Treatment Rooms
a "PLAN REVIEWER
a FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Tom McCabe
1909 State Street, San Diego, CA 92101
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Tom McCabe Telephone # 619-233-8740
Date contacted ^ )Jo , (by (^) Fax # 169-233-8741
Mail ^Telephone Fax ^ In Person
REMARKS
By Doug Moody
Esgil Corporation
D GA D MB D EJ D PC
Enclosures
3/24/03 tmsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 *• Fax (858) 560-1576
City of Carlsbad O3-549
3/31/03
RECHECK PLAN CORRECTION LIST
JURISDICTION City of Carlsbad PLAN CHECK NO 03-549
PROJECT ADDRESS 2101 Costa Del Mar Rd SET II
DATE PLAN RECEIVED BY
ESG1L CORPORATION 3/24/03
REVIEWED BY Doug Moody
DATE RECHECK COMPLETED
3/31/03
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
A Please make all corrections on the original tracings and submit two new sets of prints to
ESGIL CORPORATION
B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections Please contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
QYes QNo
City of Carlsbad O3-549
3/31/03
Please make all corrections on the original tracings, as requested in the correction
list Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
1 A complete description of the activities and processes that will occur in this
tenant space should be provided A listing of all hazardous materials should be
included The materials listing should be stated in a form that would make
classification in Tables 3-D and 3-E possible The building official may require a
technical report to identify and develop methods of protection from hazardous
materials Section 307 1 6 Please indicate the classification of the oils to be
stored
2 Please indicate what will be stored in the 55 gallon containers'? Please indicate
if the corridor is a rated corridor9 If so please revise the plans to show a
rated separation between to oils and the rated corridor Please revise the
plans to show the oil dispensing not to occur in an exit corridor, exit
corridor shall not be used for purpose's other than exiting
3 Please revise the LTG forms to show the installed lighting wattage not to exceed
the allowable wattage Please clarify the LTG forms the total area is
incorrect, the use of the room is not a classroom or lecture room
4 Please indicate if the mechanical system will be altered If so please provide
complete plans Please indicate if the new 6" exhaust duct is penetrating a
rated corridor9 Show compliance with section 713 10
8 Provide dryer vent to outside The maximum length is 14 feet with two 90-degree
elbows UMC, Section 504 3 2 Please revise the note to show a dryer vent
9 Please indicate if the new dryer is gas or electric9 The panel schedule indicates
a 20 120v circuit9 Please provide the listing information for the stacked
washer/ dryer indicating the installation requirements
City of Carlsbad 03-549
3/31/03
10 Show a level area, or landing, per Section 1133B 242 Please revise the plans
to show door D-5 to comply Please revise the plans to show the restroom
door to not encroach into the required turn area of the disabled accessible
restroom more than 12"
a) >60" in the direction of door swing
b) >48" in the direction opposite the door swing (or 44" if doors don't
have latches or closers)
11 The work room counters shall be 28" to 34" from the floor Section 1122B 4
Please revise the plans to show the new attendants storage to comply with
section 1125B 1
EsGil Corporation
In (Partnership with government for (BmUing Safety
DATE 3/10/O3
JURISDICTION City of Carlsbad
PLAN CHECK NO O3-549 SET I
PROJECT ADDRESS 2101 Costa Del Mar Rd
PROJECT NAME La Costa Resort and Spa Chopra Center - Treatment Rooms
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
| | The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X] The applicant's copy of the check list has been sent to
Tom McCabe
1909 State Street, San Diego, CA 92101
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Tom McCabe Telephone # 619-233-8740
Date contacted 3//c/fc3 (by KV) Fax # 169-233-8741
Mail Telephone Fax./' In Person
1 REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 2/27/03 tmsmtldot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
City of Carlsbad 03-549
3/10/03
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO O3-549
OCCUPANCY B
TYPE OF CONSTRUCTION VN
ALLOWABLE FLOOR AREA
SPRINKLERS'? YES
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 2/26/03
DATE INITIAL PLAN REVIEW
COMPLETED 3/10/03
JURISDICTION City of Carlsbad
USE Spa Treatment
ACTUAL AREA 946sf
STORIES 2
HEIGHT
OCCUPANT LOAD 9
DATE PLANS RECEIVED BY
ESGIL CORPORATION 2/27/03
PLAN REVIEWER Doug Moody
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i e. plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
City of Carlsbad 03-549
3/10/03
Please make all corrections on the original tracings, as requested in the correction
list Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
1 A complete description of the activities and processes that will occur in this
tenant space should be provided A listing of all hazardous materials should be
included The materials listing should be stated in a form that would make
classification in Tables 3-D and 3-E possible The building official may require a
technical report to identify and develop methods of protection from hazardous
materials Section 307 1 6
2 Please indicate what will be stored in the 55 gallon containers'?
3 Please revise the LTG forms to show the installed lighting wattage not to exceed
the allowable wattage
4 Please indicate if the mechanical system will be altered If so please provide
complete plans Please provide the required MECH forms to show energy
compliance The MECH forms shall be signed and attached to the plans
5 When new rooms or spaces are constructed and the existing mechanical system
is not to be altered other than relocation of existing duct work, please note or
show mechanical ventilation will be provided capable of supplying outside air at a
minimum rate of 15 cubic feet per minute per occupant UBC, Section 1202 2 1
6 Provide complete plumbing plans, including
a) Complete drain, waste and vent plans
b) Provide gas line plans and calculations, showing pipe lengths and gas
demands UPC Section 1217 0
c) Provide complete water line sizing calculations, including the water
pressure, pressure losses, water demands, and developed pipe lengths
UPC Section 6100
d) Show water heater size, type and location on plans UPC, Section 501 0
City of Carlsbad 03-549
3/10/03
7 Note on the plans that new water closets and associated flushometer valves, if
any, shall use no more than 1 6 gallons per flush and shall meet performance
standards established by the American National Standards Institute Standard
A112 19 2 H & S Code, Section 17921 3(b)
8 Provide dryer vent to outside The maximum length is 14 feet with two 90-degree
elbows UMC, Section 504 3 2
9 Please indicate if the new dryer is gas or electric? The panel schedule indicates
a 20 120v circuit?
10 Show a level area, or landing, per Section 1133B 242
a) >60" in the direction of door swing
b) >48" in the direction opposite the door swing (or 44" if doors don't have
latches or closers)
11 The work room counters shall be 28" to 34" from the floor Section 1122B 4
12 Please revise restroom elevation 2 to show that grab bars comply with the
following, per Section 1115B 8
a) They shall be securely attached 33" above the floor, and parallel
NOTE Where a tank-type toilet is used which obstructs placement of the rear grab
bar at 33", the rear grab bar only may be installed as high as 36"
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet, note or detail number,
calculation page, etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly
describe them and where they are located in the plans
Have changes been made to the plans not resulting from this correction list?
Please indicate
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation Thank you
City of Carlsbad O3-549
3/1O/03
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad PLAN CHECK NO 03-549
PREPARED BY Doug Moody DATE 3/1O/03
BUILDING ADDRESS 2101 Costa Del Mar Rd
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN
BUILDING
PORTION
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
946
cb
Valuation
Multiplier
City Valuation
By Ordinance
Reg
Mod
VALUE ($)
27,840
27,840
1994 UBC Building Permit Fee
1994 UBC Plan Check Fee
Type of Review
D Repetitive Fee
Repeats
Complete Review
D Other
,—i Hourly
Structural Only
Hour'
Esgil Plan Review Fee
Comments
$231 87
$15072
$129 85
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB O~l— J""?f DATE 3
ADDRESS
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR
[< $10,000.00)
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER ten**1 */f6MdL
PLANNER DATE
ENGINEER DATE
Docs/Mfsforms/Ptanning Engineering Approvals
MAYTAG STACKED V/ASHER/DRYER
INSTALLATION INSTRUCTIONS
FACTORY STACKED VERSION
The installation, including a proper exhaust system, is the responsibility of the owner
LEAVE THESE INSTRUCTIONS WITH THE OWNER
For further information, call 1-888-4-MAYTAG (1-888-462-9824).
Printed n U S A 0-0599
Read this before you start...
TOOLS needed for installation
• Teflon tape or pipe joint
compound (gas)
• Cutting knife
• Pipe wrench (gas)
• 5 16" nut driver
• Livel
• Screw driver (standard)
• Duct tape
• Crescent wrench
• 3/8" nut driver
(electric-US only)
ITEMS PROVIDED
Electric Washer/Dryer Only Gas Wash er/ Dryer Only
Mate sure you have everything necessary for proper installation
1 GROUNDED ELECTRICAL OUTLET is required See Electrical Requirements starting on page 6
2 POWER CORDS for electric dryers (except Canada
3 GAS LINES (if a gas dryer) must meet National and Local Codes
4 EXHAUST SYSTEM - use rigid metal or flexible meal exhaust ducting See Exhaust Requirements in
this section
5 UTILITIES SHUT OFFS (electric, gas and water) must be accessible after installation
MOTE Dryer door reversal instructions are on page 14 f gures 17 and 18
Location
of Canadianterminal
block(gasmodels)
Connection
Gas Manifold
27Vz"
•699cm-
395/32"
995cm
Exit location of
washer drain hose
1 6cm
Location c F dryer terminal
block on t 'lednc models
and pow< >r supply cordon g. is models
71 Vz"1816cm
Va" mm
5cm
Dryer
343cm
1 Location of
washer watervalve connections
Washer
9cm
1W
29cm
271/a"•699crrr
Paoe 1
F LEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE STARTING TO INSTALL THE
DR\ER THESE INSTRUCTIONS SHOULD BE RETAIN ED FOR FUTURE REFERENCE
F OR GAS DRYERS THE INSTALLATION MUST CONFC RM WITH THE NATIONAL FUEL GAS CODE
ANSI Z223 1, LATEST REVISION ANY QUESTIONS CONCERNING THIS SHOULD BE REFERRED TO
THE LOCAL GAS UTILITY
FIEMOVETHE DOOR FROM ALL DISCARDED DRYERS TO AVOID THE DANGER OF A CHILD
S.UFFOCATING
LOCAL CONSIDERATIONS
1 he appliance should be located to permit adequate room in front for loading the dryer and sufficient room
behind the dryer tor the exhaust system
1 he dryer is factory-ready for rear exhaust To exhaust out the left side, use an accessory exhaust kit
available from your dealer Instructions are included with the kit
When tnstalling the dryer the following minimum clearancas to combustibles apply, clearance to wall and
s ides - 0 inches Top - 0 inches with outside exhaust, re ar - 0 inches with outside exhaust, 6 inches with
nside exhaust If an inside exhaust is used (not recommended)8 inches clearance must be maintained
<ibove top
It is important to make sure the room has adequate make-ip air The area where the dryer is located must not
obs' ruct the flow of combustion or ventilating air There mu ,t be a minimum of 36 square inches of unobstructed
£.pace surrounding the dryer
For a gas dryer, adequate clearance as noted on the data plate must be maintained to insure adequate air for
combustion and proper operation of the dryer
THE DRYER MUST NOT BE INSTALLED OR STORED N AN AREA WHERE IT WILL BE EXPOSED TO
WAFER AND/OR WEATHER THE DRYER AREA IS TO BE KEPT CLEAR AND FREE FROM
COMBUSTIBLE MATERIALS, GASOLINE AND OTHER :LAMMABLE VAPORS AND LIQUIDS A DRYER
PRODUCES COMBUSTIBLE LINT THE AREA AROUN D THE DRYER SHOULD BE KEPT FREE OF LINT
EXHAUSTING
WARNING -
The dryer must be
exhausted to the
outside to reduce the
risk of fire
Exhausting the dryer to the outside is
mandatory to prevent large amounts of
moisture and lint from being blown into
the room
WARNING -
Plastic or nonmetal flexible
duct presents a potential
fire hazard
NEVER USE PLASTIC
OR NONMETAL
FLEXIBLE DUCT
If your existing ductwork is plastic, nonmetal or
combustible, replace it with metal Use only metal
exhaust duct that will not support combustion to
insure the containment of exhaust air, heat and lint
FOR BEST PERFORMANCE USE A MINIMUM OF 4-INCH DIAMETER RIGID ALUMINUM OR RIGID
GALVANIZED STEEL DUCT Ducts larger than 4 inches in diameter can result in increased lint accumulation
Lint accumulation should be cleaned regularly If flexible metal duct must be used, the type with a stiff sheet
metal wall is preferred
Exhaust Hood Type
Number
Of
90° Turns
y^ih/ / j
\y><lr
4*
/^JK/ / )
I ^^
2-1/2"
Maximum length ol 4-inch diameter
ngtd met al duct
0
1
2
3
4
65ft
54ft
44ft
36ft
28ft
59ft
48ft
38ft
30ft
22ft
Maximum length o 4-inch diameter
flexible stiff wallsd metal duct
0
1
2
3
4
36ft
32 ft
28 ft
25ft
23ft
28ft
24ft
20ft
17ft
15ft
Keep exhaust duct as straight and short as possible
drying times, affect machine operation and may collect
Do not use screws
haust systems longer than recommended can extend
I nt Secure joints with duct tape
DO NOT exhaust dryer into any wall, ceiling, crawl saace or a concealed space of a building, gas vent,
or any other common duct or chimney This could c reate a fire hazard from lint expelled by the dryer
The exhaust duct should end with an exhaust hood with a swing out damper to prevent backdrafts and entry
of wildlife NEVER use an exhaust hood with a magnetic damper The hood should have at least 1 2 inches of
clearance between the bottom of the hood and the ground or other obstruction The hood opening should
point down NEVER install a screen over the exhaust a Jtlet
When possible, do not exhaust the dryer directly into a window well in order to avoid lint build-up Do not
ex haust under a house or porch
If exhaust ductwork must run through an unheated ares, the duct should be insulated and slope slightly down
towards the exhaust hood to reduce condensation and int build-up
If an existing exhaust system is to be used with your dryer(s) you must be sure-
• The exhaust system meets all local, state and natonal codes
• That plastic flexible duct is not used
• To completely inspect and clean all lint accumulati ig from the interior of the duct
• The duct is not kinked or crushed
• The exhaust hood damper opens and closes freelv
Inspect and clean the interior of the exhaust system at least twice a year Disconnect electric service prior to
cleaning Check gas line on gas dryers anytime the dr/er is moved
Frequently check to be sure the exhaust hood damper opens and closes freely
Pa 36 3
WASHER REQUIREMENTS
Writer pressure of 20 to 120 p s i is required to correctly fill the washer to the proper levels
DRAIN FACILITY
Recommended height of the stand pipe is 36 inches If the stand pipe is less than 36 inches high the dram
hose should be routed through the clip to raise the hose to the proper height Stand pipe must be large
enough to accept the outside diameter of the drain hose
W'thaut the 36 inches high elevation, water may run OL t of the washer prematurely Should the washer
fill and drain at the same time could indicate that the dram lose has not been elevated to the proper height
The drain hose is attached at the factory
Maximum flow rate is 12 gallons per minute
FLOORING
For best performance the washer must be installed on a sclidly constructed floor Wood floors may need to be
re nforced to minimize vibration and/or unbalanced load sit jations Carpeting and soft tile surfaces are con-
triDutng factors in vibration and/or tendency for a washer to move slightly durmg the spin cycle Never install
th9 washer on a platform or weak supported structure
LOCATION CONSIDERATIONS
It is recommended the washer never be installed in areas where water may freeze since the washer will
alwavs maintain some water in the water valve, pump and hose areas This can cause damage to belts,
pump, hoses and other components Operating temperature should be above 60°F
Page 4
GAS REQUIREMENTS
Use1 only Natural or LP (liquid propane) gases
rHE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES,
WITH THE NATIONAL FUEL GAS CODE ANSI/2223 1, IATEST REVISION (FOR THE UNITED STATES),
OR WITH THE CAN/CGA-B149 INSTALLATION CODES (FOR CANADA)
A gas dryer is equipped with a burner orifice for operation on NATURAL gas If the dryer is to be operated
on LP gas, it must be converted for safe and proper performance and must be converted by a qualified
service technician Conversion kits from NATURAL to I P, or LP to NATURAL are available through your
local dealer (see Accessories) If other conversions are tequired, check with the local gas utility for specific
information concerning conversion requirements
Eac h dryer will provide an input of 22,000 B TU per hou
<\ 1/2 inch gas supply line is recommended and must be i educed to connect to the 3/8 inch gas line on the
dryer
The internal gas shut-off is accessed by removing the access panel on the dryer The shut-off is positioned
for easy access near the gas valve
The National Fuel Gas Code requires that an accessible approved manual gas shut off valve be installed
Mthin 6 feet of the dryer
Additionally, a 1/8 inch N PT (National Pipe Thread) plucged tapping, accessible for test gauge connection,
must be installed immediately upstream of the gas suppl/ connection to the dryer
The dryer must be disconnected from the gas supply pipirg system during any pressure testing of the system
DO NOT re-use old flexible metal gas line Flexible gas me must be design certified by American Gas
Association (CGA in Canada) NOTE Any pipe joint co npound used must be resistant to the action of
anv liquefied petroleum gas
NOTE As a courtesy, most local gas utilities will mspec a gas appliance installation
GAS IGNITION -
The dryer use an automatic ignition system to ignite the b jmer There is no constant burning pilot
GROUNDING
• Improper connection of the eq Jipment-groundmg conductor can result in a risk of
electrical shock Check with s qualified electrician or serviceman if you are in
doubt as to whether the applie nee is properly grounded
• Do not modify the plug providad with the appliance - if it will not fit the outlet,
have a proper outlet installed hy a qualified electrician
• To Prevent unnecessary risk (f fire, electrical shock or personal injury, all wiring
and grounding must be done n accordance with the National Electrical Code
ANSI/NFPA, No 70-Latest Revision (for U S) or the Canadian Electrical code
CSA C22 1-Latest Revision (br Canada) and local codes and ordinances It is
the personal responsibility and obligation of the appliance owner to provide adequate electrical services
for this appliance
All gas installations must be done in accordance wi h the National Fuel Gas Code ANSI/2223 1-Latest
Revision (for the U S ) or the CAN/CGA-B149 Installation Codes-Latest Revision (for Canada) and local
codes and ordinances
Pag =5
ELECTRICAL REQUIREMENTS
NOTE-- Wiring diagram is located inside the access p inel
Export models (not U.S or Canada)
S88 Additional Instructions for Export Models on the followi ig
pages
GROUNDING
Each dryer must be grounded In the event of malfunction >r
breakdown, the ground will reduce the risk of electrical sho ;k by
providing a path of least resistance for electrical current
GAS MODELS
Ec;Ch appliance is equipped with a cord having an equipment-grounding
conductor and a grounding plug The plug must be plugged irto an
appropriate outlet that is properly installed and grounded in accordance
wi h all local codes and ordinances
Do not modify the plug provided with the appliance - if it wil not fit the
outle', have a proper outlet installed by a qualified electrician
WARNING ~ To prevent
unnecessary risk of fire,
e'ectnca' shock or
personal injury, all wiring
and grounding must be
done in accordance
with local codes, with
the National Electrical Code,
ANSI/NFPA (for the United States)
or the Canadian Electrical Code
CSA C22 1 (for Canada)
If a separate ground is required by local codes, an accessoy ground wire and ground clamp is available
Connect ground wire to back of unit with the cabinet ground screw and washer The ground screw and washer
are found in the parts package Secure other end of ground wire to a suitable external ground connection
The wire may be secured with the clamp to a grounded CC LD metal water pipe NEVER CONNECT
GROUND WIRE TO PLASTIC PLUMBING LINES, GAS LNES OR HOT WATER PIPES
ELECTRIC MODELS
If a power cord is not used and the electric dryer is to be perma-
nently wired, the dryer must be connected to a grounded m 3tal,
permanent wiring system, or an equipment grounding conductor
rr ust bo run with the circuit conductors and connected to th3
equipment grounding terminal
U S Electric models are shipped with a ground strap connected
from the neutral terminal block post to the frame of each dr/er If
k'cal codes prohibits the use of the ground strap, the dryer nust be
grounded in accordance with local codes
WARNING Improper
connection of the
equipment grounding
conductor can result in
a nsk of electric shock
Check with a qualified
electrician or serviceman if you are m
doubt as to whether the appliance is
properly grounded
E ach electric dryer must be connected to a grounded meta,
permanent wiring system, or an equipment grounding cond jctor
must be run with the circuit conductors and connected to tr e
equipment grounding terminal
ELECTRICAL CONNECTIONS (seepage 12 for connections)
EiEFORE OPERATING OBTESTING, follow all grounding instructions in Grounding Section above
An individual branch (or separate) circuit serving only this appliance is recommended DO NOT USE AN
(EXTENSION CORD
GAS MODELS - U S and Canada
A 120 volt, 60 Hz AC, approved electrical supply, with a 15 ampere fuse or circuit breaker is required
Page 6
E.ECTRIC MODELS - U.S. and Canada
A 120/240 volt 60 Hz AC approved electrical service fusee through a dedicated 30 ampere fuse or circuit break-
er on both sides of the line is required
If a power cord is used, the cord should be plugged into a dedicated 30 ampere receptacle
U S ELECTRIC MODELS
Tie power cord is NOT provided with U S electric model dryers
IMPORTANT When permitted by local codes, the dryer eiectncal supply may be connected by means of a
n<9w power supply cord kit, marked for use with clothes dn'er, that is U L listed, rated at 120/240 volts
rr inimum.. 30 amperes with three No 10 copper wire cond Jctors terminated with closed loop terminals,
oDeri-end spade lugs with turned up ends or with tinned leads
Co rot reuse a power supply cord from an old dryer The power cord electric supply wiring must be retained
at the dryer cabinet w/th a suitable UL listed strain relief
If the dryer is to be installed in an area where local codes do not permit grounding through neutral, only a
4 conductor power cord, rated and terminated as above, nay be used
120/208 Volt Electrical Systems
/US electric washer/dryer must be converted if it is to OF erate on a 120/208 volt electrical system A heating
element conversion kit is available for the dryer along with a transformer for the washer (see Accessories)
CANADIAN ELECTRIC MODELS
All Canadian models are shipped with the power cord attached
fit Is not permissible to convert a dryer m Canada to 208 volts
Additional Instructions for Export Models
mot U.S. or Canada)
Contact the distributor that sold the appliance or Maytag International, 8700 W Bryn Mawr Avenue, Chicago
'llmois USA 60631, 773-714-0100, for information on product, shipping damage, replacement parts and
accessories
Vlaytag models manufactured for operation on 60 Hz AC are not designed for use on 50 Hz AC
3lectncal service and conversion of the product from 60 1o 50 Hz operation is not recommended For
additional information on 50 Hz products, contact Maytac International
The electric service requirements can be found on the data label located on the front of the dryer behind the
door
EXPORT ELECTRIC MODELS
Export electric models are manufactured for operation on either 230/240 volt, 50 Hz or 220 volt. 60 Hz
approved electric service A two-wire approved electrical service with a 30 ampere fuse or circuit breaker is
required The dryer must be properly grounded with a ground wire
IMPORTANT When permitted by local codes, the dryer electrical supply may be connected by means of a
new power supply cord krt, marked for use with clothes dryers, that is agency listed, rated at 240 volts
mnimum, 30 amperes with two No 10 copper wire conductors terminated with closed loop terminals,
open-end spade lugs with turned up ends or with tinned leads
Do not reuse a power supply cord from an old dryer The power cord or electric supply wiring must be
retained at the dryer cabinet with a suitable agency listed strain relief
Pag » 7
ADDITIONAL INFORMATION
REPLACEMENT PARTS AND ACCESSORIES
If the dryer requires replacement parts or accessories, cor tact your local Maytag dealer from whom you
purchased your appliance or
Maytag Customer Service
240 Edwards Street, S E
Cleveland, Tennessee 37311
Pnone 1 -888-4-MAYTAG (1-888-462-9824), for mformatior on the nearest authorized Maytag Parts Distributor
EXPORT MODELS
Contact the Commercial Distributor from whom you purchased your appliance or
Maytag International
8700 W Bryn Mawr Avenue
Chicago, Illinois, USA 60631
Fhone 773-714-0100, for information on the nearest authorized Maytag Parts Distributor
Pag< 8
To install...
1, Carefully remove any packaging materials from the outside of the appliance Set
aside two corner posts for installation IMPORTANT Notice that the hoses are tied
up with a shipping strap (See figure 1) The strap should not be cut or removed
until the machine ts ready to be installed After shipping restraints (straps
and bolts) have been removed, machine MUST be transported in the upright
condition
/.. Lay two corner posts behind the appliance and
gently tip the appliance over on to its back
(See figure 2)
3. Remove the crate bottom from the appliance
(See figure 3)
Figure 1
Figure 2
Figure 3
4. Locate the front two 1/2" hex head shipping bolts on bottom
of metal base Remove both bolts, to free the tub and
suspension (See figure 4) DO NOT BE ALARMED as
the last bolt is removed, the tub will jump to a position
where it is resting against the back of the washer
Shipping
Bolts Figure 4
51. Loosen the four adjustable washer legs and lock nu s enough to fit a wrench on the
lock nut (See figure 5) Install vinyl feet found in ir stallation package
Carefully raise the washer back to an upnght position
Figure 5
6. At the installation site, locate the metal buckles attached to the shipping straps at back of washer
Carefully cut away straps (see figure 6) near both t uckles, completely removing both buckles from
the washer (See figure 7)
Pull loose straps from back of
washer one at a time until all
straps have been removed
Figure 6
Pags9
Figure 7
7'. Remove hose from the dram hose clip
Place the dram hose in the dram facility To chang 3 drain hose direction
or prevent hose from collapsing or becoming dam? ged, turn the end of
the hose while holding the base of the hose stationary (See figure 8)
HOSE
RETAINER
SERVICE
UNIT
Be sure an air-tight connection is not made betwee i the
dram hose and the standpipe Standptpe must be at
least 24" high 36" he;ght rs recommended
(See figure 9)
NOTE Caution must be always be exercised to a\ Old
collapsing or damaging the dram hose For best
performance the dram hose should not be restricted in
any way, through elbows, couplings or excessive
lengths
Route drain hose through the dram hose clip on the
rear wall of washer
For installations where the dram hose cannot be co i-
veniently elevated to at least 24", the dram hose mi st be
supported by the dram hose clip on the back of the
washer The dram hose should be tied down with the
cable tie provided
Inslall one screen strainer and washer at the fauce end of each fill
hose The dome on the screen strainer must point towards the
faucet (See figure 10)
Attach the inlet hoses with the screen washer to th 3 HOT and
COLD faucets Tighten by hand until snug and the i 2/3 of a turn
with pliers Do not overtighten NOTE Accesso y inlet hoses are
available in various lengths up to 10 feet
Slide appliance into position Make sure the drair hose remains
routed straight through the drain hose dip without collapsing
or damaging NOTE the appliance must be le\ eled on all
4 sides To properly level a machine, the top co ver and the
front panel must be securely fastened. A carpenter's level
should be used on all 4 comers of the top. It's a good idea to
check for level again after the first dozen washes and re-level
if necessary.
LAUNDRY
ivTUB
STANDPIPE
60" MAX
36* WIN
Figure 9
WATER FAUCET
WASHER
SCREEN
HOSE
Figure 10
Page C
For gas dryers apply joint compound or about 1-1/2 wraps of Teflon tape
ever threaded connection on the end of the gas pipe 'See figure 11)
An elbow is recommended, for additional depth, pointing down to allow
the unit to be located further back into the alcove
Note Pipe joint compound must be resistant to the action of any liquefied
petroleum gas
Add additional fitting to connect the 3/8 inch gas pipe o a female threaded
end of a 3>4 inch flexible connector making sure the connection is tight Figure 11
Check all gas supply connections from service valve for leaks using a soap
solution, DO NOT use an open flame to check for <ias leaks If bubbles occur, tighten the
connections and recheck
NOTE. As a courtesy, many local gas utilities will tns[>ect a gas appliance installation Check with your
local utility to see if this service is provided in your art a
NOTE1 The minimum permissible gas (natural or mix 3d) supply pressure for purposes of input
adjustment is 4 5 inches of water
Move unit into position, level and tighten the leveling lock nuts on the legs Secure the vent pipe to the
exhaust duct with a 4 inch vent clamp
Page 11
8. For electric dryers-
TO MAKE ELECTRICAL CONNECTION FOR U 5 DRYERS
Review electrical requirements on page 6 of thes^ instructions
IMPORTANT - All U S models are produced for a 3-WIRE
SYSTEM CONNECTION The dryer frame is grounded to the
neutral conductor at the terminal block A 4-WIRI SYSTEM
CONNECTION is required for new or remodeled ( onstruction,
mobile homes, or if local codes do not permit grounding through
neutral If the 4-wire system is used, the dryer fre me cannot be
grounded to the neutral conductor at the terminal block Refer
to the following instructions for 3- and 4-WIRE SVSTEM
CONNECTIONS
Remove the terminal block cover plate (See figu e 12)
Insert the power cord with a U L listed strain relief through the
hole provided in the cabinet near the terminal block Note, a
strain relief must be used
3-WIRE SYSTEM CONNECTIONS
Do not loosen the nuts already installed on the tei mmal block
Be sure they are tight Use a 3/8 inch deep nul d iver
If the power cord has terminals, place the terminals over the
existing nuts on the posts The neutral (white or center wire on
power cord) conductor must always be connected to the center
(silver colored) post of the terminal block
Secure in place using the nuts provided in the parts package
If Ihe power cord does not have terminals, use the cupped
washers ahead of the nuts
Be sure the terminal block nuts are tight Secure he power
cord in position Tighten the strain relief screw{s) in order to
clamp the strain relief to the cord (See figure 13 )
Replace the terminal block cover
BEFORE OPERATING OR TESTING, follow the grounding
directions on page 5
4-WIRE SYSTEM CONNECTIONS
Remove the ground strap screw from the terminal block support
Fold the ground strap over so both ends of the ground strap are
attached to the center terminal block post
Connect the neutral (white) conductor of the cord to the center
(silver) post of the terminal block Connect the grounding
(green) wire of the cord to the terminal block support using the
ground strap screw
Connect the red and black wires of Ihe cord to th€ outer posts
of the terminal block
Be sure the terminal block nuts are on tight Secure the power
cord in position Tighten the strain relief screw(s) n order to
clamp the strain relief to the cord (See figure 14 i
Replace the terminal block cover
WARNING If converting from 4-wire electrical systems to
3-wire, the ground strap must be reconnected to terminal block
support to ground the dryer frame to the neutral conductor
Terminal Block
Cover Plate
\7
Figure 12 t I
240/208
VAC
Figure 13
3-Wire System with
( )Power Cord Attached
Ground
.''Strap
Neutral
Strain
relief
4-Wire System with
Power Supply Attached
Neutral
Post
240/2I
VAC
Figure 14
«_ 120 VAC Fo|ded
Ground
Strap
Neutral
Strain
Relief
Page 12
2-Wire and Ground System
heutral
Post
Neutral
Figure 15
Power
cord
and
strain
relief
9.
2-WIRE AND GROUND SYSTEM
CONNECTIONS
Remove the terminal block cover plate
Insert the power cord with an agency listed strain
relief through the hole provided in the cabinet near
the terminal block Note, a strain relief must be
used.
Do nol loosen the nuts already installed on the
• ermmal block Be sure they are tight Use a
3/8 inch nut driver
Secure the power cord ground wire to the terminal
block support using the ground screw
(See figure 15)
If the power cord has terminals, place the
terminals over the existing nuts on the posts
The neutral wire in power cord must be
connected to the center (silver colored) post
of the terminal block
Secure in place using the nuts provided in the
parts package If the power cord does not have
terminals, use the cupped washers ahead of the nuts
Be sure the terminal block nuts are tight Secure the power cord in position Tighten the strain relief
screw(s) »n order to clamp the strain relief to the cord
Replace the terminal block cover
BEFORE OPERATING OR TESTING, be sure the machine is properly grounded
EXPORT GAS MODELS
Export gas models are manufactured for operation on either 230/240 volt, 50 Hz or 220 volt, 60 Hz AC
approved electrical service with a 15 ampere fuse oi circuit breaker
Export gas models have been manufactured for use with natural gas having a higher heating value of
approximately 1025 BTU per cubic foot Conversion to LP gas with a higher heating value of
approximately 2500 BTU per cubic foot must be perormed by a qualified service technician A
conversion kit is available
Remove washer and dryer timer knobs from
miscellaneous parts package and insert them
on the respective shafts NOTE Timer shafts
are different between the washer and dryer
(See figure 16)
Tigure 16
Page i3
"i 0. Directions tor reversing the dryer door
1 Remove the hinge hole covers and screws Mo/e the door calch cover to the opposite side
2 While supporting the door, remove 4 screws in • he hinges that secure the hinges to the cabinet and
set the door down
3 Move the following parts to the opposite side of the door 2 hinges and 4 hinge screws, 4 door
screws, door strike and screw, inner door cover plate and screw
4 Attach the door to the opposite side of the cabnet using the 2 counter sunk hinge screws
{See figure 17)
5 Replace the hinge hole covers to the opposite side
Figure 17
"-.^ >
N\^ \v>
rDoc r Catch Counter Sunk Screw
~7^w~\\
Cover Plate
* -[-Hinge
J
v Screws
Door
'strike
~Door
11 - Directions for reversing the washer door*
1 Swing door fully open and support it while rerr oving four hinge screws {which hold hinges to door
assembly)
2 Set door aside and transfer four color matched door screws to the opposite side of the door assembly
3 Remove one screw holding top hinge to cabin at and one screw holding top hinge cover to cabinet
(opposite side)
4 Remove hinge and bracket from cabinet by m wing them up and down to a position where they are
released
5 Install hinge and bracket m swapped locations and drive screws to attach them securely to the
cabinet
6 Compare top hinge and top bracket to bottom hinge and bottom bracket for correct assembly
position
7 Repeat procedures 4 through 6 for bottom hir ge to cabinet and bottom bracket to cabinet
8 Support door in fully open position on hinge £ ide and drive four screws to secure attach hinges to
door assembly
9 Close door and check to see that clothes was her operates properly
Figure 18
Psae 14
INSTALLATION ACCESSORIES
• Vent hood - 4" (10 16cm) opening - 059129
• Aluminum pipe - 4" x 24" (10 16cm x 60 96cm) - 05C130
• Aluminum elbow -4" (10 16cm) -059131
• Aluminum window plate - 15" x 20" (38 10cm x 50 80cm) - 4" (10 16cm) hole - 059134
• Clamp for 4" duct - 304630
• Exhaust duct kit for base or left side exhausting - 33( 01881
• Rectangular vent kits - 059144
• Back draft damper 4" - 059146
• NATURAL to LP conversion kit - 306195
• LP to NATURAL conversion kit - 306204
• Anchor bracket kit - 303740
• Heating element conversion kit, 208 v, - 308590 (NOT FOR CANADA)
• Grounding wire - 311155
• Ground clamp-301548
• Power cords - 240 v, 30 A
10'- 3-wire-33001838
10'-4-wire-33002441
Page 16
^>>^N
5 ^\1
^^
<£
?
I
&
fr
!
m T3 O C/3
S T
-n O
>H
C)>z
> -n-033
P
>
<s
\m
$*
k
•>^f
S
0
£>•x-
^D.
J
}\
77
dy
^^c^•-«,fj
"^
*
oooiTinm-ucoKd?^[nj3?r-c
o m
-1ITl §
M O
OO"
m "o
«i
S o
G; ~ > i -a m
g $ > [[]^ ^
Z 5 5 H O Q
O -° O ^
r~2c S
w>
I— H <D I" OO — K> > rn
S m Z°** rr> O W
^§1o m > w
5i§^MSSS^2
Oo>
DDm
ocm
OO m
oo
rn