Loading...
HomeMy WebLinkAbout2120 JANIS WAY; ; CB023126; PermitApplicant: KNUDSEN TOBIN 2120 JANIS WAY CARLSBAD CA 92008 c—\ \ ") $61.19 Plan Check Add'I Plan Check Fe Strong MohonFee/ (' "y U1111 Renewal Fee AddI Renewal Fee .. - / '-- -7 \ n nn Other Building Fee Additional Fees / TOTAL PERMIT FEES $101.96" Total Fees: $101.96 Total: Payments ' /To Date: 1 /1 $0.00 -'Balance Due: $101.96 INCORPORATED \ . : / 0118'I'2/03/03 0002 01 02 CGF 10196 \ / -- 7/ 1— /7 FINALAPPRO1VAL Insnctnr/ J' "(/ Date: - V Clearance: Building Permit AAA-1 D.. NA; .-.-.0 4 17S Owner: -----'--KNUDSEN TOBIN 2I20JANIS WAY CARLSBAD,CA 92008... / L H.) 7) City of Carlsbad \,\1635 Faraday Av Carlsbad, CA 92008 t2-03--2003 Retaining Wall Permit Permit No: CB023126 Building Inspection Request Line (760) 602-2725 Job Address: 2120 JAN IS WY CBAD Permit Type: RETAIN Status: ISSUED Parcel No: 1672402200 Lot #: 0 Applied: 12/03/2003 Valuation: $4190.00 Construction Type: NEW Entered By: SB Reference #: Plan Approved: 12/03/2003 Issued: 12/03/2003 Project Title: KNUDSEN RES 266 SF KEYSTONE Plan Check#: WALL Inspect Area: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any FOR OFFICE USE ONLY - PERMIT, APPLICATION .- PLAN-CHECK NO. -_ i.'ié ESL VAL. 'S 'CITY OF CARLSBAD BUILDING DEPARTMENT S ' Plan.Ck.'Depos', 1635 Faraday Ave, Carlsbad, CA 92008 Validated By______________________ Date__________________ VIMFS Wpft AcTdrebs (include Bldg/Suite #) Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No: Total # of unit ApPrcel # re,ijg Use S , Proposed Use Description of WcJk 0. FT. 76( '#of Stories - # of Bedrooms - # of Bathroom Name - Address City State,Z,p Ti-ephon # Fax '# A gRn for Owner Name - Address , City State Zip TOephori, 0 'T;'ri,/ Name - Address City State/Zip Telephone # / [ (Sec. 7031.5 Business and -Professions Code: Any City or County which requires a permit to construct-alter, improve, demolish or repair any structure, -prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant' to the provisions of the Contractor's License Law [Chapter 9 commending with Section 7000 of Division 3-of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged ,exemption. Any violation of Section 7031.5 by any applicant for a permit subjectsthe applicant,to a civil penalty-of not more than five hundred dollars't$5001). - Name - - - Address -; S City - State/Zip Telephone '# - - State License # ' -' License Class ' City BuCiness License#_- Designer Name ' . - Address - : . City - State/Zip Telephone - State Liáense # W,SQKERS,COMPENSATION ,. * Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the follriwing declarations: , 0 - I have and will maintain a certificate of Consent to self-insure for workers' compensation-as provided by Section 3700 of the Labor Code, 'for the performance .of the work for which this permit is issued. - 0 I have and will maintain workers' compensation, as required by Section '3700 of the Labor Code, 'for 'the performance of the work for which this permit 'is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. - Expiration Date__________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) 0. CERTIFICATE OF EXEMPTION: I certify that in the performance of the, work for which this permit is issued;' I shall no 11 t employ any pers6 in in any manner so as to become subject to the Workers' Compensation Laws of California. ' , ' S ' •, ,, '- ' WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an' employer' to criminal penalties and civil fines upto one'hundred - thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Laborcode,'interest and attorney's fees. SIGNATURE ' DATE'____________________ 7. OXNERJJLDER.DECL RATION T I herebyaffirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor s ' License' Law does notapply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). ' C3 I,. as owner of the property, am exclusively contracting with licensed contractors to, construct 'the project (Sec. 7044, 'Business 'and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contraètor)s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for donstruction of the proposed property improvemènt,,"ES, ONO' I (have / have not) signed an application for a building permit for the proposed work. - 'I have contracted with the-following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): " I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone number / contractors license number): - 5. I will provide some-of the work, bu I ave cont r cted (hired) the following persons to provide the work indicated (include name,/ address / phone number / typo of work): NPROPERTY OWNER SIGNATURE DATE /,'r ,Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management, and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Acd'ount Act? 0 YES 0 NO Is the applicant, or future,,building occupant, required to obtain a permit from the air pollution control district or air quality menagement district? . 0 YES .0 NO. Is the facility to-be ilonstructed within 1,000 feet of the outer boundary of a school site?- 0 'YES. 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFCATE,OF OCCUPANCY MAY NOT BE ISSUED UNLESSTHE APPLICANT.HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. jCONSTRUCTION_LENDINGAGENCY,j,r I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME - S '' LENDER'S ADDRESS IcANLIFlCATIoN ' - * - -- - I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all - Cit'ordinances and State laws relating to building. construction. hereby' authorize representatives- of the Citi of Carlsbad t6 enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF'CARLSBAD, AGAINST ALL - LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION:' Every permit issued by the building Official under the provisions of this Code shall expire by limitation and béãome null and void if the building or work' authorized by such permit-is not commenced within 180 days from the date of such permit or if the building or reork authorized by suc permit is suspended or abandoned at any time after the work is; coMnifor a p4io'd-of APPLICANTS SIGNATURE 180S (Section 106.4.4 Uniform Building Code): DATE WHITE: File , YELLOW: Applicant PINK': Finance - - , Inspection List Permit#: C6023126 Type: RETAIN KNUDSEN RES 266 SF KEYSTONE WALL Date Inspection Item Inspector Act Comments 02/25/2004 69 Final Masonry PD AP SAVE 02/05/2004 63 Walls PD CA 02/05/2004 69 Final Masonry PD CO see notice attached Thursday, February 26, 2004 Page 1 of 1 UNSCHEDULED BUILDING INSPECTION DATE INSPECTO PERMIT # 2- /2 ' PLAN CHEC}ç# JOB ADDRESS DESCRIPTION CODE DESCRIPTION ACT COMMENTS oq "5w cl-~ GEOTECHNICAL EXPLORATION, INC. SOIL & FOUNDATION ENGINEERING • GROUNDWATER HAZARDOUS MATERIALS MANAGEMENT • ENGINEERING GEOLOGY 18 February 2004 Tobin & Julia Knudsen 2120 Janis Way Carlsbad, CA 92008 Subject: Addendum Geotechnical ReDort Knudsen Residence Retaining Wall 212Q Janis Way Carlsbad;California Dear Mr. and Mrs. Knudsen: Job No. 03-8516 As requested, we herein respond to a City of Carlsbad memorandum prepared by the building inspector. The memorandum is dated February 5, 2004, and addresses his site observations, review of our geotechnical report, and request for additional information to complete the permit approval. Item 1: "Provide certification from soils engineer for installation of wall, including (a) founded in competent material; (b) installation of geogrid -- verify dimension of backcut required; and (c) backfill of wall complies with requirements." GEl Resronse: As stated in our "Report of Limited Geotechnical Investigation" dated November 7, 2003, the existing retaining wall is founded on good bearing, dense formational sandstone materials. Three layers of geogrid were placed behind the retaining wall during the backfilling. The geogrid reinforcement placed between the compacted backfill layers provide sufficient support for the existing soil and geometric wall conditions. The previous slope was approximately 8 feet high and sloped down to the south from the building pad at a gradient of approximately 2.0:1.0 (horizontal to vertical). No backcut was required since the wall backfill was placed on top of the existing slope surface (after preparation). 7420 TRADE STREET • SAN DIEGO, CA 92121 • (858) 549-7222 • FAX: (858) 549-1604 • E-MAIL: geotech@ixpres.com Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 2 The wall, in general, retains a narrow backdrain backfill zone of gravel behind the front blocks. In addition, compacted backfill soils (nonexpansive sandy soils.) exist behind this zone. In our opinion, the existing keystone wall, gravel backfill, and sandy backfill material are considered stable and comply with the minimum backfill requirements. LIMITATIONS The findings and opinions presented herein have been made in accordance with current generally accepted principles and practice in the field of geotéchnical engineering within the City of Carlsbad. No warranty, either expressed or implied, is made. If you have any questions regarding this letter, please contact our office. Reference to our Job No. 03-8516 will help expedite a response to your inquiries. Respectfully submitted, GE TECHNICAL EXPLORATION, INC. Jaime A. Cerros, P.E'. R.C.E. 34422/G.E. 2007 Senior Geotechnical Engineer JaY4( -Weiser Senior Project Geologist Ef No. 002007 EX.(3OIOcJ * City of Carlsbad Bldg Inspection Request For 02/05/2004 Permit# CB023126 Inspector Assignment: PD Title: KNUDSEN RES 266 SF KEYSTONE Description: WALL Type: RETAIN Sub Type: Job Address: 2120 JANIS WY Phone: 760405%9 Suite: Lot 0 Location: 0 - 'Inspect, r: APPLICANT KNUDSEN TOBIN Owner: KNUDSEN TOBIN&JULIA Remarks: Total Time: 0 Requested By: TOBIN Entered By: CHRISTINE CD Description Act Comment 69 Final Masonry Associated PCRs/CVs Inspection History Date Description Act Insp Comments EsGil Corporation In Partnership with goernrnent for (Bui&uzng Safety DATE: 11/21/03 ANT JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 02-3126 SET: II PROJECT ADDRESS: 2120 Janis Way PROJECT NAME: Retaining Wall (Knudson Residence) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LII: The plans transmitted herewith have significant deficiencies' identified onthe'enclosed check list-- - and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone ' Fax In Person LII REMARKS: By: David Yao Enclosures: Esgil Corporation DGA [:1 MB OEJ 0 P 11/18 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In cPartnersliip with Government for Building Safety DATE: 9/15/03 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-3126 O AR&LCCANT uts_) O PLAN REVIEWER 0 FILE SET:I PROJECT ADDRESS: 2120 Janis Way PROJECT NAME: Retaining Walls ( The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. Lii The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Tobin Knudsen 2120 Janis Way Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Tobin Knudsen Telephone #: (760)434-0599 Date contacted: Ci li (by: r, ) Fax #: Mail Teleohone Fax In Person REMARKS: By: David Yao Enclosures: Esgil Corporation LIGA LIMB L]EJ LI Pc 9/11 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 02-3126 9/15/03 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-3126 PROJECT ADDRESS: 2120 Janis Way FLOOR AREA: Retaining walls REMARKS: STORIES: HEIGHT: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGI.L CORPORATION: 9/11 DATE INITIAL PLAN REVIEW PLAN REVIEWER: David Yao COMPLETED: 9/15/03 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 02-3126 9/15/03 Please make all corrections on the original tracings, as requested inthe correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential pràjects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plansand calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Indicate on the Title Sheet of the plans the name of the legal owner and name of the person responsible for the preparation of the plans. Section 106.3.3. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans (structural sheets) and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). 4. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC. 5. Provide a fully dimensioned site plan drawn to scale. Section 106.3.3. Include the following: North arrow. Property lines/easements. Existing and proposed structures. 6. On the coversheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. . REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION City of Carlsbad 02-3126 9/15/03 STRUCTURAL MASONRY DESIGNER-SPECIFIED OTHER (keystone wall more than 6 feet per ICBO#45.99) When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1 804.(Check with city for the soil report requirement) Note on the plan the soils classification, whether or not the soil is expnsive and note the allowable bearing value. Section 106.3.3. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: a) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." Provide a letter from the soils engineer confirming that the foundation plan, grading plan and -specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). Show height of retained earth on all foundation walls. Chapter 16. Note on the plan that the keystone wall construction shall comply with ICBO #4599. Section 106.3.3. Note on first sheet shows keystone standards were used for the first two courses and corners. The note is not clear. The other courses not using keystone wall.(?) The note shows the hillside was benched every 3 courses. Please provide drawing to show it. The plan shows cinder block wall in front of keystone wall. What is the construction detail of the cinder block wall? Any surcharge load from the keystone wall? Provide calculation to justify it. The lCBO report #4599 shows structural calculation must be submitted to the building official for each wall system. Provide calculation to justify the wall been used. 18: Provide detail drawing for the keystone wall used for this project. City of Carlsbad 02-3126 9/15/03 CAp1 F Gil V o f -C a r I''s'b-a OF Building M1 Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 02-3126 Job Address or Legal Description 2120 Janis Way Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad an department of all work that he/she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received-and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) City of Carlsbad 02-3126 9/15/03 V).LUATI.PNAND.PLAN CHECK FEE JURlDiCTION: City of-Carlsbad PLAN CHECK NO.: 023126 - PREPARED BY: David Yao DATE: 9/15/03 BUILDING ADDRESS 2120 Janis Way BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) kestone wall Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Icb IBy Ordinance Bldg. Permit Fee by Ordinance vi E?T you ëc1&fComp. Review an curly at the same time Plan Check Fee by Ordinance V Type of Review: II1 Complete Review Structural Only Repetitive Fee IIEE1 Repeats * Based on hourly rate Comments: LI Other Hourly 1.51 HoursLfr- * Esgil Plan Review Fee I $144.00f Sheet I of 1 macvalue.doc City of Carlsbad I 1T1 1i FTA'ZT 11.11 .I.I dl iI!I BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CB 0 ,. 3( , BUILDING ADDRESS: PROJECT DESCRIPTION: Retaininq Wall ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. Date:__ DENIAL Please see attached report of deficiencie marked withX e Make necessary corrections to plans or ificatidns for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. :::: /7è/o2 By: Date: ATTACHMENTS Right-of-Way Permit Application ENGINEERING DEPT. CONTACT PERSON NAME: JOANNE JUCHNIEWICZ City of Carlsbad ADDRESS: 1635 Faraday Avenue Carlsbad, CA 92008 PHONE: (760) 602-2775 HWflRflflflJ41(1 W,fl R1n0 Fn,n, R RRn 1635 Faraday Avenue • Carlsbad, CA 92008-7314. (760) 602-2720 • FAX (760) 602-8562 19 BUILDING PLANCHECK CHECKLIST RETAINING WALLS 1 2Nf 3RD/ 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Easements Existing & Proposed Structures Retaining Wall (dimensioned from street) (location and height) Property Lines I Show on site plan: Drainage Patterns ( Existing & Proposed Slopes Existing Topography 3. Include on title sheet: , Site Address Assessor's Parcel Number Legal Description Grading Quantities Cut Fill Import/Export (Grading Permit and Haul Route Permit may be required) Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date: MISCELLANEOUS PERMITS A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. A separate Right-of-Way issued by the Engineering Department is required for the following: Please obtain an application for Right-of-Way permit from the Engineering Department. Page 1 \\ASPALAS\SYS\LIBPRYsENG\WORDOOCS\C8KLSflRetaining WO Building Plandiedc Cldst Fonn JJ.doc Rev. 6F26/98 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 6 Address Planner Greg Fisher Phone (760) 602-4629 APN: /Y7 ' 4, 1 16 Type of P oject & Use: Project Density: DU/AC Zoning: ILA- it) General Plan: J2,V Facilities Management Zone: / CFD (in/out) #_Date of participation: Remaining net dev acres:______ Circle One (For non-residential development: Type of land used created by this permit: Legend: Z Item Complete 0 Item Incomplete - Needs your action Environmental Review Required: YES NO TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: 0 Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:_____________________________________________________ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_ NO CA Coastal Commission Authority? YES_ NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. 0 lnclusionary Housing Fee required: YES - NO - (Effective dafe of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES, NO : (A2P/Ds, Activit' Maintnane, enter CB#, toolbar, Screens, Housing Fees, Cönétruct Housing YIN, Enter Fee, UPDATE!) H:\AbMlN\COUNTER\BldgPlnchkRevChklst Rev 9/01 >' C., C, C, 0 Site Plan: 4 4 E E E Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right- 'of-way width,- dimensional setbacks and existing topographical lines (including all side and rear yard slopes). E Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines 0 0 0 Applicability: YES NO ' Project complies YES NO________ Zoning: 0 0 Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown 0 0 Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street' Side: Required Shown Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required ' Shown 0 0 0 Height: Required Shown Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Requited Shown 0 Additional Comments I II /L.. - ( 1/ LL/ Te u'+i CD. po t OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE_________ H:\ADMIN\COUNTER\BIdgPIflChkReVChkISt ' ' / Rev 9/01 October 15, 2002 City of Carlsbad Code Enforcement Office RE: Property Address 2120 Janis Way, Carlsbad, CA 92008 Dear Code Enforcement Department: I am writing this letter in response to a letter I received from the City of Carlsbad. It appears that a retaining wall I constructed in my front yard does not meet the city height requirements, and that I need to apply for a permit for a gas line. I am actively working on a plan to meet the city's requirements. After consulting with several landscape designers, contractors and engineers, I have identified the following steps to take that will, when completed, change the existing wall in a manner so that it will conform with the city front yard guidelines. contact Pacific Bell to request the relocation of the telephone box currently located in the southwest corner of my property increase the height of the pre-existing wall located in front of the wall in question to 42 inches per city code requirements back-fill the area between the two walls per city code requirements remove the upper two courses of the wall in question so that the maximum height is no greater than the city required 42 inches high install a railing around the top of the existing front yard area, per city code requirements apply for a permit for the gas line, per city code requirements The landscape design firm recommended that I provide a rough plan for your approval prior to the creation of formal plans. I have included a rough sketch of the intended changes along with a photo of the pre- existing wall and telephone box. I will work with the landscape design team to create plans and implement these changes in a timely fashion upon approval of the enclosed sketch. Sincerely, I AM M MM1,05MA... FINAWMAI/2 I, MUZZAARM M Tobin Knudsen Homeowner 760-434-0599 e4%Pr.3(-?6 I. REPORT OF LIMITED GEOTECHNICAL INVESTIGATION Knudsen Residence Retaining Wall 2120 Janis Way Carlsbad, California JOB NO. 03-8516 07 November 2003 Prepared for: Tobin & Julia Knudsen By.. APpRQVED Of CARLSBAD. BUILDING DEPT. GEOTECHNICAL EXPLORATION, INC. SOIL & FOUNDATION ENGINEERING • GROUNDWATER HAZARDOUS MATERIALS MANAGEMENT • ENGINEERING GEOLOGY 07 November 2003 Tobin and Julia Knudsen Job No. 03-8516 2120 Janis Way Carlsbad, CA 92008 Subject: Renort of Limited Geotechnical Investigation Knudsen Residence Retaining Wall 2120 Janis Way Carlsbad, California Dear Mr. and Mrs. Knudsen: In accordance with your request and our proposal of October 7, 2003, Geotechnical Exploration, Inc. has performed a limited geotechnical investigation of the soil conditions at the site of the subject existing keystone block retaining wall. The field work was performed October 14, 2003, by our field geologist. This opportunity to be of service is sincerely appreciated. Should you have any I questions concerning the following report, please contact our office. Reference to our Job No. 03-8516 will help expedite a response to your inquiry. I Respectfully submitted, GEOTECHNICAL EXPLORATION, INC. I I I I. I ESSf01 . LU No. 002007 I ni Exp.30/O OF Jaime A. Cerros, P.E. R.C.E. 34422/G.E. 2007 Senior Geotechnical Engineer 7420 TRADE STREET • SAN DIEGO, CA 92121 • (858) 549-7222 • FAX: (858) 549-1604 • E-MAIL: geotech@ixpres.com TABLE OF CONTENTS PAGE I. EXECUTIVE SUMMARY 1 II. BACKGROUND 2 III. SITE DESCRIPTION 3 IV. FIELD INVESTIGATION 4 V. DESCRIPTION OF SOILS 4 VI. GROUNDWATER AND DRAINAGE CONDITIONS 4 VII. LABORATORY SOIL INFORMATION 5 VIII. CONCLUSIONS AND RECOMMENDATIONS 6 IX. LIMITATIONS 7 FIGURES Vicinity Map Plot Plan III Retaining Wall Cross Section IV. Laboratory Data Summary APPENDICES Unified Soil Classification Chart Retaining Wall Design Calculations REPORT OF LIMITED GEOTECHNICAL INVESTIGATION Knudsen Residence Retaining Wall 2120 Janis Way Carlsbad, California JOB NO. 03-8516 The following report presents the findings and recommendations of Geotechnical Exploration, Inc. for the subject project. I. EXECUTIVE SUMMARY It is our understanding that the existing retaining wall was built without a permit. I The City of Carlsbad is requiring an evaluation of the wall stability and the adjacent soil and slope conditions prior to issuing a permit. I Our investigation revealed that the existing retaining wall is underlain by good- bearing, dense, silty sandstone materials. The wall, in general, retains a narrow backdrain backfill zone of gravel. In addition, compacted backfill soils exist behind I this zone. These are non-expansive sandy soils. In or_o.pinJori the existing keystone wall, gravel backfill, and sandy backfill material are considered stable. The results of field and laboratory testing, as well as our slope stability analysis, conclude that the keystone wall is founded on dense formational material and the geogrid-reinforced backfill appears to be properly compacted. The keystone wall provides positive drainage and protection from surface erosion. It is our understanding, based on communications with Mr. Knudsen, that the existing keystone wall was not permitted and-the City of Carlsbad is requiring a geotechnical report and retaining wall stability evaluation prior to permit issuance. Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 2 With the above in mind, the scope of work is briefly outlined as follows: Identify and classify the retained soils and surface and subsurface wall bearing soils, in conformance with the Unified Soil Classification System (refer to Appendix A). Recommend wall design pressures for the existing keystone retaining wall as well as an allowable bearing capacity and other necessary soil design values for the existing site soils. 4. Provide slope and retaining wall stability calculations. II. BACKGROUND It is our understanding the keystone retaining wall was built over a year ago by the existing homeowners. The keystone wall was built at the base of an existing slope in the southwest corner of the front yard area to increase the usable yard area. The wall footing consists of a gravel layer that was placed at approximately the same elevation as the adjacent sidewalk. The keystone wall was built adjacent to an existing masonry wall on the north side of the sidewalk. As the keystone wall was built, the individual cells were filled with gravel and backfilled with sandy fill soil. Three layers of geogrid were placed behind the wall during the backfilling. After the keystone wall was completed, the existing masonry wall was raised approximately 2 feet higher (to a maximum height of 42 inches) and backfilled with gravel and similar nonexpansive sands. We understand that steel rebar was used for reinforcement of the raised portion of the masonry wall. Following completion of the masonry wall, the maximum exposed height of the keystone wall is I Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 3 I will only allow retaining walls with a maximum height of.42 inches within 20 feet of the street. I III. SITE DESCRIPTION I . The approximately 10,000-square-foot site is located at 2120 Jan' is Way, in the City I of Carlsbad. The lot is relatively level and descends moderately down to the south at the retaining wall location. The previous slope was approximately 8 feet high and I sloped down to the south from the building pad at a. gradient of approximately 2.0:1.0 (horizontal to vertical). The keystone wall is approximately 8 feet high (but I only 42 inches exposed) and extends approximately 20 feet in length across the southwest, front yard area. The wall height decreases at the radius on each end of I the wall .to zero approximately 20 feet north of the wall face. The wall is located approximately 10 to 12 feet north of Janis Way, and approximately 3 feet north of I the sidewalk. The existing masonry wall along the north edge of the sidewalk existed prior to the Knudsen's purchase of the property. I .The site is bounded to the north, east and west by existing residential properties, and to the south by Janis Way. This property supports a single-story wood frame I residential structure with an attached garage and associated improvements. . concrete driveway provides access to the property from Janis Way. I Vegetation on the site currently consists of some landscaping and lawn grass in the front yard area. I GF4Ph, 0 _ I Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 4 IV. FIELD INVESTIGATION Two exploratory pits were advanced behind the keystone wall section on the site. The pits were observed and logged by our field geologist, and samples were taken of the predominant soils throughout the field operation. Excavation cross sections have been prepared on the basis of our observations and the results have been summarized on Figure No. IV. The predominant soils have been classified in conformance with the Unified Soil Classification System (refer to Appendix A). In- place samples were obtained per ASTM D1586-98. V. DESCRIPTION OF RETAINED SOILS Soils retained by the east-west trending keystone retaining wall consist of gravel and silty sand backfill soils; These include silty sand soil derived from Pleistocene terrace deposits local to the neighborhood. The backfill soils consist of crushed rock (1-inch gravel) backdrain and silty sand fill soils. The backfill zone behind the upper portion of the wall ranges from 5 to 10 feet in thickness. VI. GROUNDWATER AND DRAINAGE CONDITIONS No groundwater was encountered during the course of our field investigation, and we .do not expect significant problems to develop in the future if the new wall structure and improvements are provided with good drainage (as presently proposed) if the recommendations are followed herein. Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 5 VII. LABORATORY SOIL INFORMATION Laboratory tests were performed on the remolded and,relatively undisturbed soil samples in order to evaluate their physical and mechanical properties and their ability to support the existing retaining wall. The following, tests were conducted on the sampled soils: 1. Moisture Content (ASTM D2216-98) Moisture/Density Relations (ASTM D1557-98, Method A) Density Measurements (ASTM D1586-98) Mechanical Analysis (ASTM D422-92) The moisture . content of a soil sample is a measure of the weight of water, expressed as a percentage of the dry weight of the sample. The relationship between the moisture and density of remolded soil samples gives qualitative information regarding the soil strength characteristics and compaction soil conditions to be anticipated during any future grading operation. Based on laboratory test data, our observations of the primary soil types on the project, and our previous experience with laboratory testing of similar soils, our Geotechnical . Engineer had assigned conservative values for friction angle, coefficient of friction, and cohesion to those soils which will have significant lateral support or bearing functions on the project. The assigned values are presented in Figure NO. IV and have been utilized in the assigning the recommended bearing value as well as active and passive earth pressure design criteria. Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 6. VIII. CONCLUSIONS AND RECOMMENDATIONS The following conclusions and recommendations are based upon the practical field investigation conducted by our firm in conjunction with our knowledge and experience with the soils in this area of the City of Carlsbad. It is our opinion that the keystone wall was placed on a gravel layer and founded on dense sandstone materials with adequate bearing capacity. The wall should remain stable as long as proper surface and subsurface drainage is provided. Based on the observed depth of the foundation for the keystone wall, no surcharge loads due to the geogrid wall are being placed on the existing masonry wall. The masonry wall does not show any evidence of distress or tilting that may indicate signs of instability. The 8-foot-high retaining wall (42 inches exposed), built of compact and large keystone blocks, gravel and soil backfill, complies with the minimum factors of safety for bearing, overturning and sliding for a face built at either a 7.1-degree tilt or a 3.5-degree tilt. The geogrid reinforcement placed between the compacted backfill layers provide sufficient support for the existing soil and geometric wall conditions. The soil bearing pressure produced by the keystone retaining wall foundation is less than 1,000 pounds per square foot (psf). The factor of safety against soil bearing failure is larger. than 2.0; the factor of safety against sliding is larger than 1.5, and against overturning larger than 2.0. (See attached calculations performed for an 8.0 foot and 6.0 foot high retaining wall). The maximum exposed height of keystone wall is 42". For review purposes, we can consider the wall Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 7 embedment 2.0 feet and exposed height 48", and the existing wall is considered acceptable. 4. It is our opinion the existing wall may be left as is. Proper drainage shall be provided at the top of the wall at all times to drain water runoff away from the wall. IX. LIMITATIONS Our conclusions and recommendations have been based on all available data obtained from our field investigation and laboratory analysis, as well as our experience with the soils and formation materials located in the City Carlsbad. Of necessity, we must assume a certain degree of continuity between exploratory excavations and/or natural exposures. The actual soil conditions between exploratory excavations may differ. The work performed and recommendations presented herein are the result of an investigation and analysis that meet the contemporary standard of care in our profession within the San Diego County area. This report should be considered valid for a period of two (2) years, and is subject to review by our firm following that time. The firm of Geotechnical Exploration, Inc. shall not be held responsible for changes to the physical condition of the property, such as addition of fill soils or changing drainage patterns, which occur subsequent to issuance of this report. Knudsen Residence Retaining Wall Job No. 03-8516 Carlsbad, California Page 8 Once again, should any questions arise concerning this report, please feel free to contact the project coordinator. Reference to our Job No. 03-8516 will help expedite a reply to your inquiries. Respectfully submitted, U I I I I I . I I I I I I Jaime A. Cerros, P.E. R.C.E. 34422/G.E. 2007 Senior Geotechnical Engineer GEOTECHNICAL EXPLORATION, INC. Jay K. Fteiser Senior Project Geologist çt ESS'OI\ K(No. 002007 I4 Qz: Ex.9130J -::\ . 40 KIN .1 Abe AR- __ \1 i \ , 50 - • 1 s - P5; .O$GARY. - -<- IR 4 rcJ ST a , - - -& - TH -14- '--- AA fr _II FVN M WINE ON lip NO Thomas Bros Guide San Diego County pg 1106 JANIS WAY I. .. / Planter Area / Sidewalk SBC Box I CONCRETE DRIVEWAY I . . . I I $ Palm .. r J F. Legend ASSUMED PROPERTY I BOUNDARY I • HP-2 APPROXIMATE LOCATION OF EXPLORATORY HANDPIT A A' I - - - - ---J CROSS-SECTION LOCATION KEYSTONE RETAINING WALL MASONRY WALL . HP-1 -_____ I X V nr ..... X 11-- ir T [ --i r • • L I T -r J S I I ars [ SCALE 1" = 5' Lj OF] . (Approximate) Wood I Fence L_ I Pit : •. ![III I HP-2 [4 ' LJ P1.01 PLAN I I - Knudsen Retaining Wail 2120 Janis Way I . . . . -• S Cwlebad, CA Figure No. I1, Job No. 03-8518 NOTE: This Plot Plan is not to be used for legal 454 Goo technical purposes. Locations and dimensions are opproxi- • . I REFERENCE' ThIs Plot Ptom was prepared from p ora on, nc. I mate. Actual property dimensions and locations - - on-sIte field reconnaissance performed by GEL of utilities may be obtained from the Approved Building Plans or the "As-Built Grading Plans 03-8516-p September 2003 '.5 SI --. • . S .5 S.-. . Knudsen Retaining Wall 2120 Janis Way Carlsbad, CA. A' Street, Planter NOTE: This Cross Section is not to be used for legal purposes. Locations and dimensions are approxi- mate. Actual property dimensions and locations of 'utilities may be obtained from the Approved Building Plans or the "As—Built" Grading 'Plans. 03-8516-xs HP-1 (5' Fill) , j HP-2 (1' 'FIll) P it Sandy Backfill 2'-S" Soil Previous Slope Surface Sandy TERRACE Bac1dl - - - DEPOSITS lk 0 5 10 FI A 11 vPt7X0 Z'/A V/z////////////A ' Ill GRAPHIC SCALE Figure No. ', ' (FEET) Job N.O. 03-8516 ' (Horizontal and Vertical) ' 4 Geotechnical ' Exploration. Inc. I ~Wp November2003 70 -2.50 --- SPECIFIC GRAVITY ZERO AIR VOIDS CURVES 80 60 z 40 u.s. I standor I 3iee 3ze3 . 9 100 .... 4444444 GRAIN DIAMETER (mm) 140 130 LABORATORY SOIL DATA SUMMARY• DIRECT SHEAR TEST 1 2 3 DATA APPARENT COHESION ) 100 APPARENT FRICTION ANGLE 34 I $.J4D I I GRAVB.1 N T0 M I 7:~~d 120 90 MAXIMUM DRY DENSITY 1 2 3 (pci) 128- OPTIMUM MOISTURE 8.o coNrail __ III H III 80 I I I I I I I I 0 10 20 30 LABORATORY COMPACTION TEST 40 SOIL TYPE SOIL COMPACTION BORING HANDPIT DEPTH No. No. 1 Orange-tan, fine to medium sand HP-1 2' 2 3. SWELL TEST DATA 1 2 3 INflAL DRY DENSITY (pci) INT1AL WATER COP4TB.il (%) LOAD (psi) PERCENT SWELL Figure No. IV JobNo. 03-8516 Geotechnlcal 1f1 ; Exploration, -Inc. APPENDIX A UNIFIED SOIL CLASSIFICATION CHART SOIL DESCRIPTION Coarse.-grained .(More than half of material is larger than a No. 200 sieve) GRAVELS, CLEAN GRAVELS GW Well-graded gravels, gravel and sand mixtures, little (More than half of coarse fraction or no fines. is larger than No. 4 sieve size, but smaller than 3") GP Poorly graded gravels, gravel and sand mixtures, little or no fines. GRAVELS WITH FINES GC Clay gravels, poorly graded gravel-sand-silt mixtures (Appreciable amount) SANDS, CLEAN SANDS SW Well-graded sand, gravelly sands, little or no fines (More than half of coarse fraction is smaller than a No. 4 sieve) SP Poorly graded sands, gravelly sands, little or no fines. SANDS WITH FINES SM Silty sands, poorly graded sand and silty mixtures. (Appreciable amount) SC Clayey sands, poorly graded sand and clay mixtures. FINE-GRAINED (More than half of material is smaller than a No. 200 sieve) SILTS AND CLAYS ML Inorganic silts and very fine sands, rock flour, sandy silt and clayey-silt sand mixtures with a slight plasticity. Liquid Limit Less than 50 CL Inorganic clays of low to medium plasticity, gravelly clays, silty clays, clean clays. OL Organic silts and organic silty clays of low plasticity. MH Inorganic silts, micaceous or diatomaceous fine sandy or silty soils, elastic silts. Liguid Limit Greater than 50 CH Inorganic clays of high plasticity, fat clays. OH Organic clays of medium to high plasticity. HIGHLY ORGANIC SOILS PT Peat and other highlyorganic soils APPENDIX B KEYSTONE RETAINING WALL DESIGN Based on Rankine (modified) Methodology A CNTCl COMPANY Project: Knudsen Date: 11/11/03 Proj. No.: ProjectNo03-85 By:jac Design Parameters Soil Parameters _L c psf Reinforced Fill: 32 0 120 Retained Fill: 34 100 120 Foundation Fill: 34 100 120 Reinforce Fill Type: Silts & sands 3 Unit Fill: Crushed Stone, 1 inch minus 2 Factors of Safety 1 Sliding: 1.50 Overturning: 2.00 Bearing: 2.00 Pullout: 1.50 Uncertainties: 1.50 Connection Peak: 1.50 Serviceability: N/A Reinforcing Parameters: Strata-Grid Geogrids Tult RFcr RFd RFid LIDS FS Tat Ci Cris SG300 3005 1.61 1.10 1.10 1542 1.50 1028 0.90 0.90 Analysis: Review of Existing Retaining Wall Case: Case 1 Unit Type: Compac Wall Batter: 4.40 deg. Leveling Pad: Crushed Stone Wall Ht: 8.00 ft embedment: 0.50 ft Level Backfill Surcharge: LL -- 0 psf uniform surcharge DL - 0 psf uniform surcharge Offset= 1.00 ft; Load Width= 100.00 ft Results: Sliding Overturning Bearing Shear Bending Factors of Safety: 16.58 26.37 19.06 6.08 6.68 Calculated Bearing Pressure: 960 psf Eccentricity at base: -0.05 ft Allow. Peak Serviceablity Reinforcing: (ft & lbs/ft) Calculated Tension Connection Connection Pullout Layer Height Length Tension Reinf. Type Tat Tcl Tsc FS 4 6.67 5.0 91 SG300 10280K 4190K N/A 1.62ok 3 4.67 5.0 223 SG300 10280K 501 OK N/A 3.58ok 2 2.67 5.0 357 5G300 1028 OK 584 OK N/A 5.50ok 1 0.67 5.0 399 50300 10280K 6660K N/A 9.12ok Reinforcing Quantities (no waste included): (% of Rein. Strength Used = 26 %) SG300: 2.22 sy/ft Pref. Serv./ Embed./ HingeHt./ -1- GEOTECIINICAL EXPLORATION, iNC - nop nf rn Internal: External 4= 32 deg 4= 34 deg a= '94.40 deg a= 94.40 deg 13 = 0.00 deg 13 = 0.00 deg 6= 0.00 deg 6 = 0.00 deg H= 8.00 ft Hn=8.00ft ka = 0.279 ka = 0.254 p = 58.80 p'= 59.80 Hinge Height: - Hg_ht - 2CG tan(batter) Hinge Ht= 13 ft Pref: Ser.i.I Embed./ HinQeHt./ -2- GEOTECHNICAL R Hand Calculation Date: 11 November 2003 Designer: Jac Project: Knudsen Case: Review of Existing Retaining Wall Design Method: Rankine-wiBatter (modified soil interface) Soil Parameters: c psf Reinforced Fill 32 0 Retained Zone 34 100 Foundation Soil 34 100 Leveling Pad: Crushed Stone Modular Concrete Unit Depth Compac 1.00 ft Geometry Infernal Stability (Horizonal geometry) Height: 8.00 ft 11 Backsiope: Angle: 0.0 deg Batter: 4.40 deg Surcharge: Dead Load:, 0 psf External Stability (Horizonal geometry) Height: 8.00 ft Backsiope: Angle: 0.00 deg Batter: 4.40 deg Surcharge: Dead Load: 0 Base width: 5.0 Minimum Design Safety Factors y pcf 120 120 120 In-Place Wt. 120 pcf Height: 0.00 ft Live Load: 0 psf Height: 0.00 ft Live Load: 0 psf sliding = 1.50 overturning = 2.00 bearing = 2.00 pullout =' 1.50 shear = 1.50 bending = 1.50 uncertainties = 1.50 connection = 1.50 Earth Pressures: A 2 H off. length Reinforcing Parameters: Strata-Grid Geogrids TO RFcr REd RFid LTDS FS Tal Ci Cds SG300 3005 1.61 1.10 1.10 1542 1.50 1028 0.90 0.90 Connection Parameters: Strata-Grid Geognds Frictional I Break Pt Frictional 2 SG300 TcI= Ntan(27. 30) + 545 2314 Tcl= Ntan(0. 00) +0 Unit Shear Data Base Shear Inter-Unit Shear Shear= N tan(40.00) Shear = N tan(26.90) + 767.44 Calculation: Calculated Reactions For the "modified" design method, the back of the mass assumed to be vertical for calculation of resisting forces. effective sliding length = 5.00 ft Earth Pressure Equations Pa=0.5H(3ka_2c.iJi) Pq=ql-ika qd Pa_h=PaCo5(5) Pq_h=PqCo) Pa_v=PnSI,<c?) Pq_v=PqSnö) Reactions are: Area Force Arm-x Arm-y Moment M. W .. I L•..i._.. WI 959.97 [0.808] 4.000 775 W2 3249.06 [3.308] 4.000 10747 '1 W2a 295.47. (1.410) 2.667 417 Pa_h 169.76 N/A [2.667] -453 Pa _v 0.00 [5.308] N/A 0 Sum V = 4504.50 Sum Mr = 11939.35 Sum H = 169.76 Sum MO = -453 Calculate Sliding at Base For Sliding, Vertical Force = WI +W2+W3+W4+qd =4505 The resisting force within the rein, mass, RI_I = N tan(32) = 2815 The resisting force at the foundation, Rf_2 = N tan(34) + (5.00 x 100.00) = 3538 The driving forces, Df, are the sum of the external earth pressures: Pa + Pql + Pqd = 170 the Factor of Safety for Sliding is Rf_I/Df = >10 Serv./ Embed./ HiñaeHt./ - 3 - nnp nf Calculate Overturning: Overturning moment: Mo = Sum Mo Mo = 453 Resisting moment: Mr = Sum Mr Mr= 11939 Factor of Safety of Overturning = Mr/Mo = 26.37 Calculate eccentricity at base: with surcharge / without surcharge Sum Moments = 11487/11487 Sum Vertical = 4505/4505 Base Length = 5.00 e = -0.051-0.05 Calculate Ultimate Bearing based on shear: where: Nq = 29.44 Nc = 42.16 Ng = 41.06 (ref. Vesic(1973, 1975) eqns) Qult= 18302 psf Equivalent footing width, B = L -2e = 5.00 / 5.00 Bearing pressure = sumV/B = 960 psf I 960 psf [bearing is greatest without liveload] Factor of Safety for bearing = Qult/bearing= 19.06 Serv./ Embed./ -4- INC. nnnp of Calculate Tensions in Reinforcing: The tensions in the reinforcing layer, and the assumed load at the connection, is the vertical area supported by each respective layer, Sv.Column [6] is 2c sqrt(ka). Table of Results ppf LE 121 11 ii £1 11 W I1 £91 [10iWJ Layer Depth zi hi ka/rho Pa (Pas+Pasd) c (5+6)cos(d)-7 Ti Tcl Tsc 0.00 0.279/59 0 0 0 0 3 1.33 91 419 N/A 2.33 0.279/59 91 0 0 91 2 3.33 223 501 N/A 4.33 0.279/59 314 0 0 314 1 5.33 357 584 N/A 6.33 0.279/59 671 0 0 671 0 7.33 399 666 N/A 8.00 0.279/59 1070 0 0 1070 Pref: Serv.I Embed./ HingeHt./ -5- GEO TECHNICAL EXPLORATION, INC. nf Tulw~~al ;_ 'U616-WA jlkriln Calculate sliding on the reinforcing: The'shear value is the lessor of base-shear or inter-unit shear. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] Layer Depth zi Li N Cds t .EE J E ..E QE .E.$.. 4 1.33 0.00 0 0.90 849 849 0.000 0 0 0 > 10 3 3.33 4.00 1549 0.90 970 1841 0.254 0 0 0 > 10 2 5.33 4.00 2429 0.90 1092 2458 0.254 0 0 0 > 10 1 7.33 4.00 3272 0.90 1214 3054 0.254 81 0 81 > 10 Pref: Serv.I Embed.! H SM nnp nf A Calculate pullout of each layer In the Coulomb, AASHTO, and Rankine methods, the FoS of pullout is calculated as the individual layer pullout (Rf) divided by the tension (Df) in in that layer. The angle of the failure plane is: 29.00 degrees from vertical [1] [2] [3] [4] [5] [6] [7] [8] Layer Depth zi jLe SumV L ...EQL Ti FS P0 4 1.33 0.82. 131 0.90 147 91 1.62 3 3.33 1.77 709 0.90 797 223 3.58 2 5.33 2.73 1745 0.90. 1963 357 5.50 1 7.33 3.68 3240 0.90 3644 399 9.12 Serv./ Embed./ HinaeHt./ - 7 - GEOTECHNICAL i.rx I INt,\.J Vi fl.LL, .) I ..) I LIV(3 1 IftZ' Check Shear & Bending at each layer Bending on the top layer the FoS of Overturning of the units. (Most surcharge loads the face.) need to be moved back from [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] Layer Depth zi Si DE DM Pv RM ES b Shear ES Sh 4 1.33 1.33 22 13 0 88 6.68 849 28.55 3 3.33 1.00 67 52 320 409 7.87 970 10.24 2 5.33 1.00 111 82 560 668 8.17 1092 6.76 1 7.33 1.00 156 81 800 926 >10 1214 5.31 I I . Pref: Serv./ Embed.! Hi INC. I nri Date: 11/11/03 By:jac c psf 0 120 100 120 100 120 KEYSTUINE REIAINING WALL DESIGN Based on Rankine (modified) Methodology ANIWICCMPANY 3.1.5 Project: Knudsen Proj. No.: Project No03-85 Design Parameters Soil Parameters _____ Reinforced Fill: 32 Retained Fill: 34 Foundation Fill: 34 Reinforce Fill Type: Silts & sands Unit Fill: Crushed Stone, 1 inch minus Factors of Safety Sliding: 1.50 Overturning: 2.00 Bearing: 2.00 Pullout: 1.50 Uncertainties: 1.50 Connection Peak: 1.50 Serviceability: N/A Reinforcing Parameters: Strata-Grid Geogrids Tult RFcr RFd RFid LTDS FS Tal Ci Cds SG300 3005 1.61 1.10 1.10 1542 1.50 1028 0.90 0.90 Analysis: Review of Existing Retaining Wall Case: Case 1 Unit Type: Compac Wall Batter: 4.40 deg. Leveling Pad: Crushed Stone Wall Ht: 6.00 ft embedment: 2.00 ft Level Backfill Surcharge: LL -- 0 psf uniform surcharge DL -- 0 psf uniform surcharge Offset= 1.00 ft; Load Width= 100.00 ft Results: Sliding Overturning Bearing Shear Bending Factors of Safety: 100.00 100.00 29.36 7.59 6.68 Calculated Bearing Pressure: 720 psf Eccentricity at base: -0.11 ft Allow. Peak Serviceablity Reinforcing: (ft & lbs/ft) Calculated Tension Connection Connection Pullout Layer Height Length Tension Reinf. Type Tal Tcl Tsc FS 3 4.67 4.0 91 SG300 1028 OK 4190K N/A 1.53ok 2 2.67 4.0 223 SG300 1028 OK 501 OK N/A 3.49 ok 1 0.67 4.0 288 SG300 10280K 5840K N/A 6.70ok Reinforcing Quantities (no waste included): (% of Rein. Strength Used = 20 %) SG300: 1.33 sy/ft Pref. Serv./ Embed.! -1- GEOTECIIN INC nap. Af Hand Calculation Date: 11 November 2003 Designer: Jac Fit i'HH Project: Knudsen Case: Review of Existing Retaining Wall Design Method: Rankine-WEl atter (modified soil interface) Soil Parameters: 6 c psf Reinforced Fill 32 0 Retained Zone 34 100 Foundation Soil 34 100 Leveling Pad: Crushed Stone Modular Concrete Unit Depth Compac 1.00 ft Geometry Internal Stability (Horizonal geometry) Height: 6.00 ft Backsiope: Angle: 0.0 deg Batter: 4.40 deg Surcharge: Dead Load: 0 psf External Stability (Horizonal geometry) Height: 6.00 ft Backsiope: Angle: 0.00 deg Batter: 4.40 deg Surcharge: Dead Load: 0 Base width: 4.0 Minimum Design Safety Factors y pcf 120 120 120 In-Place Wt. 120 pcf Height: 0.00 ft Live Load: 0 psf Height: 0.00 ft Live Load: 0 psf sliding = 1.50 overturning = 2.00 bearing = 2.00 pullout = 1.50 shear = 1.50 bending = 1.50 uncertainties = 1.50 connection = 1.50 Earth Pressures: A 2 sin 2 asin(a-[1+] H !sn(Ø+6)n(Ø- ) 1 Internal: External 4= 32 deg 4= 34 deg a= 94.40 deg a= 94.40 deg 13 = 0.00 deg 13 = 0.00 deg 6= 0.00 deg 8= 0.00 deg H = 6.00 ft Hn = 6.00 ft .ka = 0.279 ka = 0.254 p = 58.80 p = 59.80 Hinge Height: - Hg_ht - 2CG tan(batter) Hinge Ht= 13 ft Pref: Serv./ Embed.! HingeHt./ -2 - GEOTEC ftl U INC. ii \ H!2 off. length A Reinforcing Parameters: Strata-Grid Geogrids Tult RFcr RFd RFid LTDS FS Tal Ci Cds SG300 3005 1.61 1.10 1.10 1542 1.50 1028 0.90 0.90 Connection Parameters: Strata-Grid Geognds Frictional 1 Break Pt Frictional 2 SG300 Tcl= Ntan(27.30) + 545 2314 Tcl= Ntan(0.00) +0 Unit Shear Data Base Shear Inter-Unit Shear Shear = N tan(40.00) Shear = N tan(26.90) + 767.44 Calculation: Calculated Reactions For the "modified" design method, the back of the mass assumed to be vertical for calculation of resisting forces. effective sliding length = 4.00 ft Earth Pressure Equations qd Pa=0.5H(ka_2c./) Pq=ql-Jka qI Pa_h=PaCo(8) Pq_h=Pq Cos (c) _Aq Pa_v= PaS(c) Pq_v= PqSi) Reactions are. H' Area Force Arm-x Arm-y Moment _L WI 719.98 [0.731] 3.000 526 W2 1827.59 [2.731] 3.000 4991 W2a 166.20 [1.308] 2.000 217 Pah 0.00 N/A [2.000] 0 Pa _v 0.00 [4.231] N/A 0 Sum V= 2713.78 Sum Mr= 5734.41 Sum H = 0.00 Sum Mo = 0 Calculate Sliding at Base For Sliding, Vertical Force = Wi +W2+W3+W4+qd =2714 The resisting force within the rein, mass, Rf_1 = N tan(32) = 1696 The resisting force at the foundation,. Rf_2 = N tan(34) + (4.00 x 100.00) =2230 The driving forces, Df, are the sum of the external earth pressures: Pa + Pql + Pqd = 0 the Factor of Safety for Sliding is Rf_1/Df = >10 Pref: Serv./ Embed./ HinqeHt./ -.3 - GEOTECHNICAL fl1A flf A CC#4n= COMPANY Calculate Overturning: Overturning moment: Mo = Sum Mo Mo=0 Resisting moment: Mr = Sum Mr Mr= 5734. Factor of Safety of Overturning = Mr/Mo = 100.00 Calculate eccentricity at base: with surcharge / without surcharge Sum Moments = 5734/5734 Sum Vertical = 2714/2714 Base Length = 4.00 e = -0.111-0.11 Calculate Ultimate Bearing based on shear: where: Nq = 29.44 Nc= 42.16 Ng = 41.06 (ref. Vesic(1973, 1975) eqns) Qult=21137 psf Equivalent footing width, B = L -2e = 4.00 / 4.00 Bearing pressure = sumV/B = 720 psf / 720 psf [bearing is greatest without liveload] Factor of Safety for bearing = Qult/bearing= 29.36 Pref: Serv.I Embed./ H -4- EXPLORA nnnA nf A GVfl CCMPANY Calculate Tensions in Reinforcing: The tensions in the reinforcing layer, and the assumed load at the connection, is the vertical area supported by each respective layer, Sv. Column [6] is 2c sqrt(ka). Table of Results ppf Ui £21 I1 141 LQ L1 0. [1 L1 1101 fill Layer Depth zi hi ka/rho Pa (Pas+Pasd) c (5+6)cos(d)-7 TiTd Tsc 0.00 0.279/59 0 0 0 0 2 1.33 S 91 419 N/A 2.33 0.279/59 91 0 0 91 1 3.33 223 501 N/A 4.33 0.279/59 314 0 0 314 0 5.33 288 584 N/A 6.00 0.279/59 602 0 0 602 Pref: Ser'.I Embed.) HingeHt./ -5- GEOTECHNIAL EXPLORATION, INC. nt1p nf Calculate sliding on the reinforcing: The shear value is the lessor of base-shear or inter-unit shear. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] Layer Depth zi Li N Cds t ..EE.. ka ...E .E ...QE ..E. 3 1.33 0.00 0 0.90 849 849 0.000 0 0 0 > 10 2 3.33 3.00. 1149 0.90 970 1616 0.254 0 0 0 > 10 1 5.33 3.00 1789 0.90 1092 2098 0.254 0 0 0 > 10 Pref: Serv./ Embed.! - 6 - GEOTECHNICAL nf T I Calculate pullout of each layer In the Coulomb, AASHTO, and Rankine methods, the FoS of pullout is calculated as the individual layer pullout (RI) divided by the tension (DI) in in that layer. The angle of the failure plane is: 29.00 degrees from vertical [1] [2] [3] [4] [5] [6] [7] [8]. Layer Depth zi jLe SumV Ci .fQL Ti FS P0 3 1.33 0.77 124 0.90 139 91 1.53 2 3.33 1.73 691 0.90 777 223 3.49 1 5.33 2.68 1716 0.90 1930 288 6.70 Pref: Serv.I Embed.! Hi -7- GEO INC. nnrtp. nf III Q. Check Shear & Bending at each layer Bending on the top layer the FoS of Overturning of the units. (Most surcharge loads need to be moved back from the face.) [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] Layer Depth zi Si QE .QJ.. ..Ey... fiL FS b Shear ES Sh 3 1.33 1.33 22 13 0 88 6.68 849 28.55 2 3.33 1.00 67 52 320 409 7.87 970 10.24 I 533 1.00 111 59 560 668 >10 1092 6.76 rl ref: Serv./ Embed.! HingeHt./ -8- GEOTECHNICAL EXPLORATION, INC. flflR flf k -44 ti, I &I ~~XVJA - cr 4j: ••'-I -. -C - - '- ,_ YN '.. ...•, •- -