Loading...
HomeMy WebLinkAbout2121 PINTORESCO CT; ; CB143074; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 01-05-2015 Residential Permit Permit No: 0B143074 Building Inspection Request Line (760) 602-2725 Job Address: 2121 PINTORESCO CT CBAD Permit Type: RESDNTL Sub Type: RAID Status: ISSUED. Parcel No: 2164813100 Lot #: 0 Applied: 11/0712014 Valuation: $10,554.00 Constuction Type: 5B Entered By: SKS Occupancy Group: Reference#: Plan Approved: 01/05/2015 # Dwelling Units: 0 Structure Type: . Issued: 01/05/2015 Bedrooms: 0 Bathrooms: 0 Inspect Area: Orig PC #: Plan Check #: Project Title: SALAZAR RES - 153 SF REMODEL COVERT ATTIC SPACE INTO GUEST BATHROOM• Applicant: Owner: GILLENWATER KYLE SALAZAR FAMILY TRUST 11-30-10 11439 EL NOPAL 2121 PINTORESCO CT LAKESIDE CA 92040-2712 CARLSBAD CA 92009, 619-733-8134 Building Permit $123.01 Meter Size Add'I Building Permit-Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $86.11 Meter Fee $0.00 Add'I Plan Check Fee $37.14 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $1.37 PFF (3105540) . $0.00 Park in Lieu Fee $0.00 PFF (4305540) . $0.00 Park Fee .$0.60 License Tax (3104193) . $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee , $0.00 Traffic Impact Fee (4305541) $0.00 BTD42 Fee . $0.00 Sidewalk Fee $0.00 BTD #3 Fee . , $0.00 PLUMBING TOTAL $77.00 Renewal Fee $0.00 ELECTRICAL TOTAL $45.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $44.59 Other Building Fee $0.00 Housing Impact Fee $000 HMP Fee $0.00 Housing InLieu Fee ' $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00. Red., Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (5B1473) Fee $1.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $415.22 Total Fees: ' $415.22 Total Payments to Date: $415.22 Balance Due: $0.00 FINAL7,PVAL .1 Insoector: /4y4,L -- Date: ______________ Clearance: - I NOTICE: Please take NOTICE tt approval of your project includes the'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions. You have 90 days fromthe date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32:030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: ,#LANNING jjuINEERING 8ILDING EIFIRE DHEALTH DHAZMATIAPCD! Building Permit Application Plan Check No. t t(rcit of 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value fL) Ph: 760-602-2719 Fax: 760-602-8558 Cd1sbad email: buiIdingcarlsbadca.gov Plan Ck. Deposit IT '5i www.carlsbadca.gov -.r Date f / / 7/I •1 Iswppp -. I JOB ADDRESS -7 17-1 P,wToESW C.oi'tr+ ISUITE#/SPACE#/UNITt I ApN I - - - ,T/P)JECT# LOT PHASE # # OF UNITS # BEDROOMS I # BATHROOMS TENANT BUSINESS NAME CONSTR. 1YPE 0CC. GROUP '. I •7e 3 I 2. DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Prc,tc COr(i.Q( 0C ))•S+I#1¼ 4+ic e, /1+0 . . 0 . EXISTING USE coi h I PROPOSED USE I GARAGE (SF) . PATIOS( IDECKS (SF) FIREPLAG NoEl I' lAIR CONDITIONING vp° FIRE SPRINKLER I EI YESDN 5jrc'j€. IS't Pti'iiyI _APPLICAWT NAME GIt.Li)TEI Primarycontact iVLE PROPERTY OWNER .SA ADDRESS I193') E . . ADDRESS ?Io -SCo C"i CITY STATE ZIP c_eq CITY STATE ZIP _Car-196o,,A CA _________________________ PHONE FAX _ __ PHONE 8 139 EMAIL 7LEO N 10 L 0 . EMAIL DESIGN PROFESSIONAL I.2tJ. . OR BUS. NAM CONTRApec&j+y Wo",e proveiev'rt ' ADDRESS 11 %43A EL ftJoP/L . ADDRESS q P J)1 CITY STATE ZIP C.J° '2ptJO CITY STATE ZIP 'or,4(ch gzoZ(p PHONE t733Ii l PHONE -138. OZ70 no FAX EMAIL TL. EOt'J L TINE, EMAIL ISTATE LIC. # STATE LIC.# 3 :.• I CLASS _~; CITY 8 aw 4\ (Sec. 7031.5 Business and Professions Code: Any Cityor County which requires a permitto construct, alter, improve, demolish or repair any Structure, prior to its issMfjte, also requiresjhe \ applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter , commefldingwith Secrf 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violationof Section .7031.5 by any applicant for a perrtfit kubjects the applicant to a civil oenaltv of not more than five hundred dollars ($50011. 9CWa13 00 Workers' Compensation Declaration: I hereby affinn under penalty of perjury one of the following declarations: . . I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, tot the performance of the work for which this permit is issued. ave and will maintaIn workers' compensation; as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance canier and poli number am: Insurance Co. efl cA rn cr- k - n u c.e PolicyNo. _C5r3005Z g Expiration Date0( 0/ ZO1 Thi section need not be completed if the permit is for one hundred dollars ($100) or less. ti Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penaltiesand civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, dama as as adfiF In Secti . 6 of the Labor cogs,interest and attorney's fees. .gCONTRACTORSIGNATURE 0E.0 0 DATE 1/. ' 1/ I hereby affirm that I am exempt from Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale, If, however, the building or Improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively conlràcting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section _____________Business and Professions Code for this mason: 0 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement [:]Yes [—]No 2.I(have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): 0 0 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address phone contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated(include name address! phone !type of work): .PROPERTY OWNER SIGNATURE 0 . DAGENT 0 DATE 0 •, - C. COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address wvAPPLICANT CERTIFI C A TION IcertifythatI have mad the application and state thatthe above information isconactandthatthe Information on the plans isaccurate. I agree tocomptywith all City ordinances and State laws relating tn building consIruction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within l8o days from the date of such permit orif the building orwoik authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Urubm Building Code). ..APPLICANT'S SIGNATURE DATE 7. / 4f STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 6024560, Email bUiIdinacarIsbadca.pov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTiONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On pg. 1) ASSOCIATED CB" MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On P. NO CHANGE IN USE / NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION .APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB143074 Type: RESDNTL RAD Date Inspection Item 03/05/2015 89 Final Combo 03/05/2015 89 Final Combo 02/05/2015 17 Interior Lath/Drywall 02/05/2015 18 Exterior Lath/Drywall 01/21/2015 21 Underground/Under Floor Inspector Act - RI PY AP PY AP PY AP PY AP SALAZAR RES - 153 SF REMODEL COVERT ATTIC SPACE INTO GUEST BAT Comments Monday, March 09, 2015 Page 1 of 1 2/2/ CERTIFICATE OF COMPLEWON INSTALLATION OF INSULATION RETROFIT The undersigned certifies that insulation has been installed at the stated location to the specifications below. Date of Installation completion: 02/03/15 Place of Installation (owners name).- Address: 2121 Pintoresco Court City: _Carlsbad State: CA Zip: Description of Installation Ceilings Saff Type of Material: fiberglass batts Manufacturer Johns Manville Thickness: 10 R-Value: R30 Coverage Area: 165 SQ ft Blown: Type of Material: Manufacturer Initial Installed Thickness:____________________ Minimum Settled Thickness Number of Bags Used: R-V&ue: Coverage Area: Exterior Walls Type of Material: fiberglass batts Manufacturer Johns Manville Thickness: 31/211 R-Value: R13 Coverage Area: 235 SQ ft Floors Type of Material: Manufacturer Thickness: R-Value: Coverage Area: Crawfspace Type of Material: Manufacturer Thickness: R-Jälue: Coverage Area: Other Areas (specify) Title 24 Air Infiltration Type of Material: Manufacturer Thickness: R-Value: Coverage Area: 1CM Member insulation Contractor Company Name: J & L Insulation, Inc. License No.: 472996 Street Address: 10035 Maine Ave City.. Lakeside State&...Zip:92O4O Company Representative Print Name: John J Keilman Signature: J&wk IeiLtwwi Date: 02/03/15 EsGil Corporation In Partners/lip wit/i government for eftiffing Safety DATE: 12/17/2014 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-3074 PROJECT ADDRESS: 2121 Pintoresco Court SET: II O APPLICANT puRIs. U PLAN REVIEWER U FILE PROJECT NAME: Convert Portion of Attic to Habitable for Salazar Residence LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. III The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. LII EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person REMARKS: Match Clouded note on sheet A2.0 to all sets. By: Ray Fuller (By DA) Enclosures: EsGil Corporation E) GA D EJ 0 MB 0 Pc 12/08/2014 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560.1468 • Fax (858) 560-1576 EsGil Corporation In (Partnership wit/i covernment for (Buitifing Safety DATE: 11/18/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-3074 SET: I PROJECT ADDRESS: 2121 Pintoresco Court L3 .,APPLICANT /1 JURIS. U PLAN REVIEWER U FILE PROJECT NAME: Convert Portion of Attic to Habitable for Salazar Residence El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: El EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Jesse Leon 4).ate contacted: I N (bym4-) 'MaiI Telephone Fax In Person El REMARKS: Telephone #: (619) 733-8134 Email: jleonkldráfting.com By: Ray Fuller Enclosures: EsGil Corporation [:1 GA DEJDMB [:1 PC 11/12/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 14-3074 11/18/14 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 14-3074 JURISDICTION: Carlsbad PROJECT ADDRESS: 2121 Pintoresco Court FLOOR AREA: STORIES: 2 Covert Attic 153 HEIGHT: Existing REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: 11/07/14 ESGIL CORPORATION: 11/12/14 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Ray Fuller COMPLETED: 11/18/14 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prjor to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 14-3074 11/18/14 1. Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Verify final sets of architectural sheets will again be signed by designer and that the structural sheets and any new calculations will be stamped and signed by engineer of record also. 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2013 California Residential Code, which adopts the 2012 IRC, 2012 UMC, 2012 UPC and the 2011 NEC. Old codes noted on cover sheet. 4. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California 513407. 5. Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. 6. Show or note that a battery-operated smoke alarms will be provided in all existing bedrooms, hallways leading to bedrooms and on each floor. 7. Show or note that a battery-operated carbon monoxide alarms will be provided outside each separate sleeping area in the immediate vicinity of the bedrooms and on each story. Section R315.2. 8. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. Carlsbad 14-3074 11/18/14 9. The energy calculations do not address the new roof area of 157 sq ft. Assume will be R-30 ? Cross section on A2.0 to reflect depth to existing rafters. 10. If applies: If depth is less than R-30 than 2 xl 0's then plans to reflect how R- 30 is to be obtained as generally requires 8 1/4" insulation plus linch airspace above? 11. Recheck plans for tempered window locations i.e. within 5 ft radius of tubs . See 4636 on A2.0. Section R308.4 12. The plans do not reflect what type of light is to be provide above bathtub. No pendant, chandeliers, cord suspended lighting , track lighting, paddle fans etc allowed shall be located within a zone measured 3 ft horizontally and 8 ft vertically from the top of the bathtub rim or shower shall threshold per NEC 410.10. Any fixtures within this zone must flush and listed for damp location and if subject to shower spray and then must be listed for wet location. 13. All hot water piping sized W or larger is required to be insulated as follows: 1" pipe size or less: 1" thick insulation; larger pipe sizes require 11/2 ' thick insulation. 14. Bathrooms (defined as having a shower or tub), shall be provided with mechanical ventilation (an openable window is not allowed). Need to add for bath area as water closet compartment considered a separate room. CalGreen 4.506.1. 15. Detail the installation requirements necessary when installing a central heating furnace opening into a bedroom or bathroom (per CIVIC Section 904.1): Non-direct vent appliance: Listed gasketed self closing and latching door assembly with a threshold and with all combustion air supplied from the. outdoors. Specify that the appliances are of the direct vent style. (assume existing is not direct vented) Please verify adequate combustion air is provided for the FAU as appears from cross section that will now be placed in a confined space. . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, buildins conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 16. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Carlsbad 14-3074 11/18/14 Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC 4.505.3. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. It is not clear if existing ceiling joist are to remain and setting 2 x1 2's between ceiling joist or removing ceiling joist and using new 2 x12's as ceiling for rooms below. If removing existing ceiling joist then verify connections of new floor joist to existing ceiling joist will be able to resist tension forces. No headers shown for exterior windows and will new 4036 opening adversely affect existing lateral at exterior wall? Note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Carlsbad 14-3074 11/18/14 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes() No () The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208,San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. neet i or I macvalue.doc + Comments: Carlsbad 14-3074 11/18/14 [DO NOT PAY — THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 14-3074 PREPARED BY: Ray Fuller DATE: 11/18/14 BUILDING ADDRESS: 2121 Pintoresco Court BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION VB BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Covert Attic to 153 68.98 10,554 Habitable Air Conditioning Fire Sprinklers TOTAL VALUE 10,554 Jurisdiction Code Icb IY Ordinance Bldg. Permit Fee by Ordinance v Plan check Fee by Ordinance Type of Review: El Complete Review El Structural Only I $123.461 El RepetiUve Fee I Repeats El Other Hourly Hr. c * EsGil Fee I $69.141 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 11-24-14 PROJECT NAME: SALZAR RESIDENCE PROJECT ID: CB14-3074 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2121 PINTORESCO COURT APN: 216-481-31-00 VALUATION: $10,554 / This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: CG 11-24-14 A Final Inspection by the Division is required -Yes /No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: JLEON@KLDRAFIING.COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760602-4610 760.602-2750 760-602-4665 Chris Sexton Chris Glassen Greg Ryan 760-602-4624 - 760-602-2784 .- - 760-602-4663 Chris.Sexton@carlsbadca.gov Christooher.Glassen@carlsbadca.gov Greeorv.Ryan@carIsbadca.gov Gina Ruiz Linda Ontiveros I Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cvnthia.Won@carIsbadca.ov Dominic Fieri 760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: Development Services BUILDING PLANCHECK Land Development Engineering CITY OF CHECKLIST 1635 Faraday Avenue 760-602-2750 CARLSBAD QUICK-CHECK/APPROVAL ENGINEERING Plan Check for CBI4-3074 Date: 11.24-14 Project Address: 2121 PINTORESCO COURT APN: 2164813100 Project Description: INTERIOR ROOM ADDITION Valuation: $10,554 ENGINEERING Contact: CHRIS GLASSEN Phone: 760-602-2784 D RESIDENTIAL INTERIOR J RESIDENTIAL ADDITION MINOR (<$20,000.00) El CARLSBAD PREMIER OUTLETS Email: Christopher.GIassencarIsbadca.gov Fax: 760-602-1052 EJTENANT IMPROVEMENT El PLAZA CAMINO REAL El COMPLETE OFFICE BUILDING El OTHER: GYM OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: CG DATE:11-24-14 REMARKS: NO ADDITIONAL ENGINEERING FEES H Notification of Engineering APPROVAL has been sent to JLEON@KLDRAFTING.COM via EMAIL on 11-24-14 E-36 Page 1 of 1 REV 4/30/11 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: Date: 11-24-14 GEO DATA: LFMZ: I B&T: Address: 2121 PINTORESCO COURT Bldg. Permit #: CBI4-3074 Fees Update by: Date: 11.24-14 Fees Update by: Date: 11-24.14 EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units . ADT's: Types of Use: Sq.Ft./Units ADT's: FEES REQUIRED: Within CFD: DYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) 0 NO 1. PARK-IN-LIEU FEE:DNW QUADRANT ONE QUADRANT DSE QUADARANT []SW QUADRANT ADT'S/UNITS: X FEE/ADT: I El 23RAFFIC IMPACT FEE: ADT'S/UNITS: X FEE/ADT: I El BRIDGE & THOROUGHFARE FEE: EJ DIST. #1 DDIST.#2 QDIST.#3 ADT'S/UNITS: FEE/ADT: El FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: X FEE/SQ.FT./UNIT: I El SEWER FEE EDU's X FEE/EDU: I El BENEFIT AREA: EDU's X FEE/EDU: I El DRAINAGE FEES: PLDA: EJHIGH EMEDIUM EJLOW ACRES: X FEE/AC: I El POTABLE WATER FEES: UNITS I CODE I CONN. FEE I METER FEE I SDCWA FEE I TOTAL 1 RECVED PLANNING DIVISION Development Services NO f! *-~BUILDING PLAN CHECK Planning Division l1014r v 0 F APPROVAL 1635 Faraday Avenue (760) 602-4610 CIT\GAR4LBA D P-29 www.carlsbadca.eov BUILDING DIVISION 1(1100-4 DATE: c8t43074 PROJECT NAME: BATHROOM AT ATTIC 2ND FLOOR LEVEL PROJECT ID: PLAN CHECK NO: C13143074. SET#: ADDRESS: 2121 PINTORESCO CT .APN: This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: JLEON@KLDRAFTING.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.Sexton@carIsbadca.gov KathIeen.Lawrence@carIsbadca.gov Gràgorv.Rvan@carIsbadca.ov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-5024662 Gina.Ruiz@carlsbadca.Eov Linda.Ontiveros@carlsbadca.gov Cynthia.Won@carIsbadca.ov Dominic Fier! 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: ATTIC AREA IS ON THE 2ND FLOOR AND DOES NOT CREATE A THIRD FLOOR AREA AS THERE IS ONLY I BEDROOM ON THE 2ND FLOOR AND THE BATHROOM CREATION WILL IS ATTACHED TO AND ACCESSIBLE FROM THE 2ND FLOOR BEDROOM.