Loading...
HomeMy WebLinkAbout2125 BASSWOOD AVE; ; CB971218; PermitBUILDING 07/22/97 12:23 Page 1 of 1 Job Address: 2125 BASSWOOD AV Permit Type: RESIDENTAL ADD/ALT Parcel No: 205-160-21-00 Valuation: 82,866 I PERMIT Permit No: CB971218 Project No: A9701586 Development No: % - %,* --. 7% ,\7 ,^-. -. I- L Suite: 'i' - ~~ Lot# : Construction Type: NEW Occupancy Group: Reference#: Status: ISSUED Description: RAD 864 SF, BALCONY 150 SF Applied: 05/13/97 Apr/Issue: 07/22/97 Entered By: JM Appl/Ownr : SMITH, BART 760 753-2464 682 2ND STREET ENCINITAS, CA *** Fees Required *** llected & Credits *** Adjustments: its: .oo ........................... .......................... Fees : 1,03 366.00 670.00 it Ext fee Data Total Fees: Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plu Each Plumbing Fix Each Install/Repai * PLUMBING TOTAL Enter "Y" for Elec Enter "Y" for Remod * ELECTRICAL TOTAL Enter 'Y' for Mechanic Install Furn/Ducts/Heat x MECHANICAL TOTAL 563.00 366.00 8.00 937.00 20.00 Y 28.00 7.00 55.00 I \ ____. 10.00 Y 10.00 Y 20.00 15.00 Y 9.00 24.00 n CITY OF CARLSBAD 2075 Las Palmas DT., Carl~bad, CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbed Building Depertmmt 2075 Lao Palms Dr., Carlsbed, U 92009 (619) 433-1161 PAP From List 1 (see back) give code of Permit-Type: _____________.-_--______________________----------------- For Residential Proiects Only: From List 2 (see back) give Code of structure-*: 5 FD Net WGain of Dwelling Units @ 2. PRc3JEcrmRMATloN \ STATE LIC. # 108 LICENSE CLASS k CITY BUSINESS LIC. # (last name tirst) Workers' Compensatlon Declaraoon: I hereby attirm that 1 have a ceruticate ot consent to selt-insure issued by the Director ot lndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSUMCE COMPANY 5 7A T&. POLICY NO. EXFTRA'I'ION DATE Certrticate ot Exemption: I certily that in the pertormance of the work tor which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE owner-Mullaer warahon: I nereoy arrirm mat I am exempt from me wntractors ucense mw tor the tonowing reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and hofgsions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section (Sec. 7031.5 Business and F%ofessions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to tile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [SSOO]). 0 0 0 Business and Professions Code for this reason: SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? IF ANYOF THE ANSWERS AREYES, AFINAL CERTWICATEOF OCCUPANCY MAY NUT BE Issvn, AFIWJULY 1,1989 UNLESS THE AppLlcANT HAS =OR IS MEEI7lG THE REQuIREkIENTsoPTHEOFplceoPEMwGENcy~~~MIDTHEALRpOLulTIoNoNTROLD~. 1 hereby attirm that there IS a construcoon lending agency tor the pertormance ot the work for which this permit is lssued [Sex 3097( 1) Ciwl code). DYES 0 NO OYES 0 NO OYES 0 NO LENDER'S NAME LENDER'S ADDRESS 1 certihr that I have read the amlicatlon and state that the above intormation IS correct. 1 am to comDIv wth all GIN ordinances and State laws relating to building constructioi: I hereby authorize representatives of the City of Carlsbad to &ter upon th; above mentikned property for inspection purposes. I AISO~REETD SAVE INDEMNIFY AND KEEPHARMLpssTHE~OFcARLsBADK;A[N~AII.~JIIM;MEKIs. a)6Is ANDEXPWSPS W" MAY IN ANY WAY AccRUEAc~srsAIDQTYIN CONSEQllENCJZ OF THE CRA"G OF THls PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended s commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANTS SIGNATU DATE: WHITE: File YELLOW Applicant PINK: Finance cs CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 09/29/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW APPLICANT: SMITH, BART PHONE: 760 753-2464 OCC GRP JOB ADDRESS: 2125 BASSWOOD AV STE : CONTRACTOR: PHONE : OWNER: PHONE: REMARKS : C/MIKE/4 3 8-047 0 SPECIAL INSTRUCT: INSPECTOR r TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 EXPIRED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical t . ***** INSPECTION HISTORY .- 41 h IL DATE DESCRIPTION 091198 Final Combo 4Mk&098 Final Combo 8 Final Combo 0498 Final Combo 98 Interior Lath/Drywall 98 Interior Lath/Drywall 862398 Service Change/Upgrade 1998 Shower Pan/Roman Tubs %a98 Shower Pan/Roman Tubs Ftg/ Founda t ion/ Piers $798 Shower Pan/Roman Tubs 16 9 8 Ftg/Foundat ion/Piers 698 Shower Pan/Roman Tubs 598 Ftg/Foundation/Piers 998 Shower Pan/Roman Tubs 98 Ftg/Foundat ion/Piers 98 Ftg/Foundation/Piers 98 Shower Pan/Roman Tubs 040898 Interior Lath/Drywall 98 Exterior Lath/Drywall 98 Shower Pan/Roman Tubs 040798 Interior Lath/Drywall 8 ‘~~4?kl’ INSP CO PK CO PD CO PD NS PD PK PK AP PK AP NF PD PD CO PD NS PK NS PK CA PD CA PD CA PK CA PK PK PK AP PK CO PK CO PK ***** COMMENTS SEE CO NOTICE ATTACHED NO ONE HOME SEE NOTICE ATTACHED W-R COMPOUND ON JOINTS NEED TO SEE W-R TAPING OK TO RESET METER LEAK AT STAIRS RESET FOR WED LEFT NOTICE IN SHOWER SEE ATTACHED CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 09/11/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE: LOT: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP REMARXS: C/MIKE/438-0470 SPECIAL INSTRUCT: /- INSPECTOR / TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO EXPIRED CD 19 29 39 49 FIA97011 FIA ISSUED LVL DESCRIPTION ACT COMMENTS ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical DATE 090898 090498 062998 062698 062398 061998 061898 061798 061798 061698 061698 061598 061598 061298 061198 042398 040898 040898 040898 040798 040798 040798 040398 040398 033098 ***** INSPECTION HISTORY DESCRIPTION Final Combo Final Combo Interior Lath/Drywall Interior Lath/Drywall Service Change/Upgrade Shower Pan/Roman Tubs Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Ftg/Foundat ion/Piers Shower Pan/Rornan Tubs Interior Lath/Drywall Exterior Lath/Drywall Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywa11 Insulation ACT INSP CO PD NS PD AP PK PA PK AP PK AP NF CO PD AP PD CO PD NS PK NS PK CA PD CA PD CA PK CA PK CO PK AP PK AP PK CO PK CO PK CO PK AP PK CO PK CO PK AP PK ***** COMMENTS SEE NOTICE ATTACHED W-R COMPOUND ON JOINTS NEED TO SEE W-R TAPING OK TO RESET METER LEAK AT STAIRS RESET FOR WED LEFT NOTICE IN SHOWER ' SEE ATTACHED CITY OF CARLSBAD NOTICE 438-3550 FOR INSPECTION CALL 438-3101. RE-INSPECTION FEE DUE? 0 YES PHONE 8 CODE ENFORCEMENT OFFICER CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 09/10/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE: LOT: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: OWNER: REMARKS : C/MIKE/4 38-04 7 0 INSPECT SPECIAL INSTRUCT: CONTRACTOR WILL CALL IN OCC GRP TOTAL TIME: --RELATED PERMITS-- PERMIT% TYPE STATUS CB961350 EO EXPIRED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST 29 PL 39 EL 49 ME -- -- -- DATE 090898 090498 062998 062698 062398 061998 061898 061798 061798 061698 061698 061598 061598 061298 061198 042398 040898 040898 040898 040798 040798 040798 040398 040398 033098 Final Structural Final Plumbing Final Electrical Final Mechanical ***** INSPECTION HISTORY ***** DESCRIPTION Final Combo Final Combo Interior Lath/Drywall Interior Lath/Drywall Service Change/Upgrade Shower Pan/Roman Tubs Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Ftg/Foundation/Piers Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywall Insulation ACT INSP CO PD NS PD AP PK PA PK AP PK AP NF CO PD AP PD CO PD NS PK NS PK CA PD CA PD CA PK CA PK CO PK AP PK AP PK CO PK CO PK CO PK AP PK CO PK CO PK AP PK COMMENTS SEE NOTICE ATTACHED W-R COMPOUND ON JOINTS NEED TO SEE W-R TAPING OK TO RESET METER LEAK AT STAIRS RESET FOR WED LEFT NOTICE IN SHOWER SEE ATTACHED \ CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 09/04/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : LOT: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: OWNER: REMARKS: C/MIKE/438-0470 INSPECT0 SPECIAL INSTRUCT: OCC GRP TOTAL TIME: --RELATED PERMITS-- PERMITa TYPE STATUS CB961350 e0 EXPIRED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical -- - DATE 062998 062698 062398 061998 061898 061798 061798 061698 061698 061598 061598 061298 061198 042398 040898 040898 040898 040798 040798 040798 040398 040398 033098 033098 032698 ***** INSPECTION HISTORY DESCRIPTION Interior Lath/Drywall Interior Lath/Drywall Service Change/Upgrade Shower Pan/Roman Tubs Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Ftg/Foundation/Piers Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywall Insulation Rough Combo Rough Combo ACT INSP AP PK PA PK AP PK AP NF CO PD AP PD CO PD NS PK NS PK CA PD CA PD CA PK CA PK CO PK AP PK AP PK CO PK CO PK CO PK AP PK CO PK CO PK AP PK AP PK PA PK ***** COMMENTS W-R COMPOUND ON JOINTS NEED TO SEE W-R TAPING OK TO RESET METER LEAK AT STAIRS RESET FOR WED LEFT NOTICE IN SHOWER SEE ATTACHED SEE ATT'D CITY OF CARLSBAD I E I7601 438-3550 2075 LAS PALMAS DRIVE I BUILDING DEPARTMENT t 7.l - I FOR I SP CTION CALL (760) 438-3101. RE-INSPECTION FEE DUE? c] YES FO F THER INFORMATION, CONTACT PHONE Q BUILDING INSPECTOR CODE ENFORCEMENT OFFICER CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 06/23/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV LOT: APPLICANT: SMITH, BART PHONE: 760 753-24 CONTRACTOR : PHONE : OWNER: PHONE : OCC GRP REMARKS: c/ INSPECTOR SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 EXPIRED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 33 EL Service Change/Upgrade ***** INSPECTION HISTORY ***** DATE 061998 061898 061798 061798 061698 061698 061598 061598 061298 061198 042398 040898 040898 040898 040798 040798 040798 040398 040398 033098 033098 032698 032598 032498 032398 032098 1031998 031898 I DESCRIPTION Shower Pan/Roman Tubs Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Ftg/Foundation/Piers Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywall Insulation Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo ACT INSP AP NF CO PD AP PD CO PD NS PK NS PK CA PD CA PD CA PK CA PK co PK AP PK AP PK CO PK CO PK CO PK AP PK CO PK CO PK AP PK AP PK PA PK NS PK CO PK NS PK CA PK CA PK CO PK COMMENTS LEAK AT STAIRS RESET FOR WED LEFT NOTICE IN SHOWER SEE ATTACHED SEE ATT'D WON'T BE READY TIL THURS/M.SH SEE ATTACH RESET FOR TUESDAY BY RAY 7:30A SEE ATTACHED RAY SAYS NOT READY 7:30AM . t CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 06/17/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCKd CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : m: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR : PHONE: OWNER: REMARKS: C/ RESET FROM TUES OCC GRP SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PEZHIT# TYPE STATUS CB961350 e0 EXPIRED PIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 11 ST Ftg/Foundation/Piere 27 PL Shower Pan/Roman Tubs I- DATE 061698 061698 061598 061598 061298 061198 042398 040898 040898 040898 040798 040798 040798 040398 040398 033098 033098 032698 032598 032498 032398 032098 031998 031898 031798 031298 031098 ***** INSPECTION HISTORY DESCRIPTION Ptg/Foundat ion/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Shower Pan/Roman Tubs Ftg/Foundation/Piers Ftg/Foundation/Piers Shower Pan/Roman Tubs Interior Lath/Drywall Exterior Lath/Drywall Shower Pan/Rorman Tubs Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywa11 Insulation Rough Conrbo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Cozabo Rough Cosbo Rough Combo Rough Combo Rough Combo ACT INSP NS PK NS PK CA PD CA PD CA PK CA PK CO PK AP PX AP PK CO PR co PX CO PK AP PK CO PK CO PK AP PK AP PK PA PK NS PK CO PK NS PK CA PK CA PK CO PK CA PK CO PK co PS ***** COMMENTS RESET FOR WED LEFT NOTICE IN SHOWER SEE ATTACHED . SEE ATT'D WON'T BE READY TIL TEURS/M.SH SEE ATTACH RESET FOR 'PflESMY -. RAY SAYS NOT READY 7:30AJ4 BY RAY 7:30A SEE ATTACHED RESET FOR WED OR "UWS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT -4 CITY OF CARLSBAD I E (760) 436-3550 BUILDING DEPARTMENT DATE 6-17-96 2075 US PALMAS DRIVE TIME PERMIT NO. % CALL (760) 438-3701. RE-INSPECTION FEE DUE? YES CONTACT PHONE Q BUILDING INSPECTOR CODE ENFORCEMENT OFFICER - City of Carlsbad June 12,1998 IDEAL FAMILY OF REMODELERS ATTN: MIKE SHEA 2958 MADISON ST CARLSBAD CA 92008 1 RE: COLLINS RESIDENCE 2125 BASSWOOD, CARLSBAD, CA; PERMIT 971218 i STOP WORK - ORDER TO REMOVE A written correction Notice was posted on the above residence on April 23,1998. That Notice directed work to stop on the master bedroom shower stall because the materials used to waterproof the shower stall were not installed correctly. A copy of that Notice is enclosed for your reference. It was observed today that the finish materials for the entire shower stall have been installed without the required corrective measures clearing inspection by the City Building Department. You are directed to remove all of the finish materials in the master bedroom shower stall, test the shower pan system, assure that Type W-R joint compound was used on the greenboard wall system, and re-call for a City inspection approval before proceeding further with this part of the project. Patrick Kelley Principal Building Inspector c: Project File Stanley Prowse, Esq. 2075 La Palmas Dr. Carlsbad, CA 92009-1576 (760) 438-1 161 - FAX (760) 438-0894 @ TIME FOR INSPECTION CALL (760) 438-31 01. RE-INSPECTION FEE DUE? 0 YES PHONE CODE ENFORCEMENT OFFICER @ SCHEDULE D BUILD ING INSP ECT?43N DATE 429% INSPECTOR E. DESCRIPTION TIME ARRIVE: TIME CODE DESCRIPTION ACT COMMENTS CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 04/08/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE: LOT: APPLICANT: SMITH, BART PHONE: 760 753-2 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP REMARKS: C/IDEAL CONST/438-0470 INSPECTOR SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO EXPIRED CD 17 FIA97011 FIA ISSUED LVL DESCRIPTION ACT COMMENTS ST Interior Lath/Drywall ST Exterior Lath/Drywall - AA-d a- - DATE ***** INSPECTION HISTORY ***** DESCRIPTION ACT INSP COMMENTS 040798 040798 040798 040398 040398 033098 033098 032698 032598 032498 032398 032098 031998 031898 031798 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Exterior Lath/Drywall Insulation Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's CO PK CO PK AP PK CO PK CO PK AP PK AP PK PA PK NS PK CO PK NS PK CA PK CA PK CO PK CA PK CO PK co PS CA PK CA PK CA PK CO PK NR PK AP PS CA PK CO PK PA PY SEE ATT'D WON'T BE READY TIL THURS/M.SH SEE ATTACH RESET FOR TUESDAY RAY SAYS NOT READY 7:30AM BY RAY 7:30A SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H. D. 'S @ SHEAR WALLS 112697 Roof/Reroof PA PK Daw 8April1998 To: File 2125 Basswood From: Principal Building Inspector Re: Ideal project Violation Tile man was tearing out previous vinyl pan liner and installing another one. I took the old pan liner after observing the installation method. The tile man stated he is an hourly employee of Ideal Construction. I took the liner to ideal's ofice on Madison Street to show Mike Shae and his foremen what had been done there. His foreman said as soon as he got my Notice on 4-7-98, he gave his hourly tile man instruction to reinstall a new pan. I told him that the fact that I had to find this violation; and his plumber actually lied to me about how the liner was installed. The plumber told me on 4-7-98 that the pan liner was lapped with an 8" lap and locked per mfg.'s requirements." Shae and his foreman apologized and said they would look at the situation. PATRICK KELLEY Principal Building Inspector Page 1 CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 04/07/98 DESCRIPTION: RAD 864 SF, BALCONY 150 SF TYPE: RAD JOB ADDRESS: 2125 BASSWOOD AV APPLICANT: SMITH, BART CONTRACTOR: OWNER: jglRCPECTOR AREA PK S&?WCK# CB971218 %mc -I? CONSTR. TYPE NEW STE : PHONE: 760 PHONE : PHONE : REMARKS: C/IDEAL CONST/438-0470 SPECIAL INSTRUCT: INSPECTOR / TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 -0 ISSUED FIA97011 FIA CD LVL DESCRIPTION 17 ST Interior Lath/Drywall 18 ST Exterior Lath/Drywall -- DATE 040398 040398 033098 033098 032698 032598 032498 032398 032098 031998 031898 031798 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 112697 112497 111797 111497 010998 ISSUED ACT COMMENTS ***** INSPECTION HISTORY DESCRIPTION Interior Lath/Drywall Exterior Lath/Drywall Insulation Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD' s Shear Panels/HD's Roof/Reroof Roof/Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation ACT INSP CO PK CO PK AP PK AP PK PA PK NS PK CO PK NS PK CA PK CA PK CO PK CA PK CO PK co PS CA PK CA PK CA PK c10 PK NR iP5 AP v% CA E% CO PK PA PY PA PK CA PK NS PK NS PK ***** COMMENTS SEE ATT'D WON',C- BE READY TIL THURS/M.SH SEE +TTACH . RESET :&OR TUESDAY * RAY SAYS NOT READYt7:30AM BY R4W 7:30A -P SEE A%%ACHED RESET POR WED OR THURS REINS? FI# REQ (SEB ATTCH) TOO MAfJY CORR TO LIQg/SEE ATT BY RAY BY RAY 8M' 3/4/98 BY ,MY IfOLCOMB [SEE OVER) TOO " &hY.''$6 LkST LEFT NOTfd *SUP". BUILDING DEPA WENT DATE 8;-.. TIME 2075 LAS PALMAS DRIVE \c f *# - LOCATION S?3T &e PERMIT NO. AD 4l4w6-e 444 6 StF fl! fY &*%& 4 &-de FOR INSPECTION CALL (760) 438-3101. RE-INSPECTION FEE DUE? 0 YES ATION, CONTACT PHONE CODE ENFORCEMENT OFFICF~P e J CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 04/03/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PUCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : CONTRACTOR : PHONE : OWNER: PHONE : OCC GRP APPLICANT: SMITH, BART PHONE: 760 REMARKS : C/IDEAL CONSTR/ 4 3 8 -04 7 0 SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 KO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 17 ST Interior Lath/Drywall 18 ST Exterior Lath/Drywall ***** INSPECTION HISTORY ***** DATE 033098 033098 032698 032598 032498 032398 032098 031998 031898 031798 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 DESCRIPTION Insulation Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Roof /Reroof Roof/Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation T-24 H-Cap Consultation Underground Combo ACT AP AP PA NS co NS CA CA co CA co co CA CA CA co NR AP CA co PA PA CA NS NS CA co INSP PK PK PK PK PK PK PK PK PK PK PK PS PK PK PK PK PK PS PK PK PY PK PK PK PK PK PX COMMENTS SEE ATT'D WON'T BE READY TIL THURS/M.SH SEE ATTACH RESET FOR TUESDAY RAY SAYS NOT READY 7:30AM BY RAY 7:30A SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. BY RAY 8m 3/4/98 EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY ? $1" OF CARLSBAD No I E (760) 438-3550 BUILDING DEPAMMENT ' 2075 LAS PALMAS DRIVE TIME A LOCATION &!/e3 r FOR INSPECTION 760) 438-3101. RE-INSPECTION FEE DUE? YES PHONE 0 CODE ENFORCEMENT OFFICER a CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 04/03/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PWCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : LOT: OCC GRP ***** INSPECPXON HISTORY ***** DATE 110797 110397 103097 101097 101097 092697 092597 072997 DESCRIPTION Underground Combo Frame/Steel/Bolting/Welding Rough Combo Shear Panels/HD's Ftg/Foundat ion/Piers Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT INSP NS PK NR PK CO PK CO PK AP PK PA PY co PY AP PK COMMENTS RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S &I STRAPS OK NO PLANS Y \ CITY OF CARLSBAD ''I E (760)438-3550 1 [ BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE DATE L CATION - FOR INSPECTION CALL (760) 438-3101. RE-INSPECTION FEE DUE? YES FOR FURTHE ATION, CONTACT PHONE (9 BUILDING INSPECTOR CODE ENFORCEMENT OFFICER I. c PERMIT# f7-/2)% - PLAN CHECK# JOB ADDRESS d/2C &d4?7m DESCRIPTION TIME ARRIVE: TIME CODE DESCRIPTION lym COMMENTS I-Deal Construction Company It has come to my attention that one of my employees callad you to discuss senior inspector Pat Kelly. I hope the wrong message'was not sent. My employee was particked over the inspection that we were trying to get at 2125 Basswood because the job is behind schedule. 1. met personally with Mr. Kelly as well as speaking to him on the phone. We discussed his concerns regarding the inspection process. As I am sure you already know, Mr. Kelly does a fine job. We at Ideal will strive in the future to have our jobs completed and ready for inspection on first call. We have recognized a need for some reorganization within our company. We hope we did not send the wrong message by our Call to you. -- MicW Shea President 32. a- 3 m 0 0 tn tn rn >r 0 c Q1 .- 0 z Principal Building Inspector D - Date: 26 March 1998 To: File 2125 Basswood From: Re: Progress and Field Discussion I met Ray Holcomb of Ideal Construction on site to review framing corrections. I reviewed all previously noted corrections. He said egress window is to be installed "this week". They had an installation guide for the furnace that was not the exact one required. The installation book indicated that the first 3 letters of the model number mean the furnace can be installed horizontally. The furnace appeared to meet all installation requirements in that booklet. Mike Shea also provided a letter stating he would have the correct manual by final inspection, and he would take responsibility for any corrections required. I left a note on the job record card that the house could be insulated but corrections remain: Install egress window and repair stud cut for heat duct in former MBR. I told Holcomb about these items also and told him he could call my boss if he still thought I was being too tough on him. Mike Shea arrived as I was leaving. He apologized for all the misunderstandings and wasted time. I told him that this type of inefficiency (30 calls for a frame sign off) on his superintendent's part was not going to be tolerated any longer. All of Ideal's jobs are plagued by wasted call-outs for inspections that are not ready. The City will charge $30 re-inspection fees for each and every call they make like this henceforth. I told him his jobs are a standing object of ridicule with the inspection staff because of the company's inefficiency and obvious code violations which are evidently not discovered by his superintendent. He committed to changing his company's standing. 0 Page 1 I-Deal Construction Cbrnnany To Pat Kelly RE: Collins project 2 125 Basswood The FAU unit used in the above residence is acceptable for horizontal use Ideal has ordered another manual and will have it by the final inspection. Ideal has researched this & will take full responsibility for the unit used at the Collins job site. Also please check the manual as noted at the bottom right hand corner of page 3 that all these types of models are acceptable for horizontal use. Thank you for your consideration. Ideal will follow up with further data. Michael C. Shea Any questions can be answered by Rick at Confort Maker 1909 5 1 7- 1750 CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/25/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : LOT: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP A REMARKS: C/IDEAL CONSTR/438-0470 SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST 24 PL 34 EL 44 ME -- -- -- DATE 3032498 ~032398 25032098 27031998 k031798 24031298 031098 2> 030698 'I( 030498 2'031898 23 022798 $0 022098 12 021098 ,7 012698 012398 P 011998 13 112697 cz 112497 111797 010998 'u 111497 ; 111397 j 111097 7 110797 -- 11 0 3 97 1 Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/ Ducts/Dampers v + ***** INSPECTION HISTORY ***** DESCRIPTION ACT INSP Rough Combo CO PK Rough Combo NS PK Rough Combo CA PK Rough Combo CA PK Rough Combo CO PK Rough Combo CA PK Rough Combo CO PK Rough Combo CA PK Rough Combo CA PK Rough Combo CA PK Rough Combo CO PK Rough Combo NR PK Shear Panels/HD's AP PS Shear Panels/HD's CA PK Shear Panels/HD's CO PK Shear Panels/HD's PA PY Roof/Reroof PA PK Roof/Reroof CA PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation CA PK Underground Combo CO PK Underground Combo NS PK Frame/Steel/Bolting/Welding NR PK Rough Combo co PS COMMENTS SEE ATTACH RESET FOR TUESDAY RAY SAYS NOT READY 7:30AM BY RAY 7:30A SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/24/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE NEW TYPE: RAD JOB ADDRESS: 2125 BASSWOOD AV STE : APPLICANT: SMITH, BART PHONE: 760 753- CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP LOT: REMARKS: C/RAY/438-0470 AM PLEASE SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST Frame/Steel/Bolting/Welding 24 PL Rough/Topout 34 EL Rouqh Electric t * 44 ME Rough/Ducts/Dampers .tgd?p ,\P+ ***** INSPECTION HISTORY ***** DATE DESCRIPTION INSP COMMENTS 032398 * 032098 - 031998 031898 031798 031298 031098 - 030698 - 022798 - 022098. 021098 - 012698 - 012398 - 011998 010998 - 112697 - 112497 - 111797 * 111497- 111397- 111097 - 110797 - 110397 103097, 030498- Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Roof /Reroof Roof /Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation T-24 H-Cap Consultation Underground Combo Underground Combo Frame/Steel/Bolting/Welding Rough Combo L@ CA CA co CA co co CA CA CA co NR AP CA co PA PA Q CA (9 co PK PK PK PK PK PK PS PK PK PK PK PK PS PK PK PY PK PK PK PK PK PK PK PK PK RESET FOR TUESDAY RAY SAYS NOT READY 7:30AM BY RAY 7:30A SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE CITY OF CARLSBAD OT' E (760)436-3550 BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE DATE &a/- 9s LOCATION 3J3-T &-- I I I I I FOR INSPECTION CALL (760) 438-3101. RE-INSPECTION FEE DUE? YES PHONE @ CODE ENFORCEMENT OFFICER CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/23/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLUCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : LOT: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP REMARKS: C/IDEAL CONSTR/438-0470 INSPECTOR SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS n 14 ST Frame/Steel/Bolting/Welding 24 PL Rough/Topout 34 EL Rough Electric - 44 ME Rough/Ducts/Dampers - DATE 031998 031898 031798 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 ***** INSPECTION HISTORY DESCRIPTION ACT INSP Rough Combo CA PK Rough Combo CO PK Rough Combo CA PK Rough Combo CO PK Rough Combo CA PK Rough Combo CA PK Rough Combo CA PK Rough Combo CO PK Rough Combo NR PK Shear Panels/HD8 s AP PS Shear Panels/HD8 s CA PK Shear Panels/HD's CO PK Shear Panels/HD8s PA PY Roof /Reroof PA PK Roof/Reroof CA PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation CA PK Underground Combo CO PK Underground Combo NS PK Frame/Steel/Bolting/Welding NR PK Rough Combo CO PK Shear Panels/HD's CO PK Ftg/Foundation/Piers AP PK Rough Combo co PS ***** COMMENTS BY RAY 7:30A SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/90 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/20/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD JOB ADDRESS: 2125 BASSWOOD AV APPLICANT: SMITH, BART CONTRACTOR : PHONE : OWNER: PHONE : REMARKS: C/RAY/438-0470 INSPECTOR SPECIAL INSTRUCT: I TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 ISSUED FIA97011 FIA ISSUED CD 14 24 34 44 LVL DESCRIPTION ST Frame/Steel/Bolting/Welding PL Rough/Topout EL Rough Electric ME Rough/ Ducts/ Dampers I J W + ***** INSPECTION HISTORY ***** DATE 031998 031898 031798 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 DESCRIPTION ACT INSP Rough Combo CA PK Rough Combo CO PK Rough Combo CA PK Rough Combo CO PK Rough Combo CA PK Rough Combo CA PK Rough Combo CA PK Rough Combo CO PK Rough Combo NR PK Shear Panels/HD' s AP PS Shear Panels/HD's CA PK Shear Panels/HD's CO PK Shear Panels/HD's PA PY Roof/Reroof PA PK Roof/Reroof CA PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation CA PK Underground Combo CO PK Underground Combo NS PK Frame/Steel/Bolting/Welding NR PK Rough Combo CO PK Shear Panels/HD' s CO PK Ftg/Foundation/Piers AP PK Rough Combo co PS COMMENTS BY RAY 7:30A SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER CITY OF CARLSBAD N om c E (760)43&3550 2075 LAS PALMAS DRIVE BUILDING DEPARTMENT DATE A TIME //Ty . LOCATION C3f3-T- &- i I I I FOR INSPECTION CALL (760) 438-3101. RE-INSPECTION FEE DUE? n YES PHONE dip CODE ENFORCEMENT OFFICER CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/19/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD JOB ADDRESS: 2125 BASSWOOD AV CONTRACTOR: PHONE : OWNER: PHONE : REMARKS: C/IDEAL CONSTR/438-0470 INSPECTOR SPECIAL INSTRUCT: OCC GRP APPLICANT : SMITH, BART PHONE: 760 753-2464 TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED CIj I 14 24 34 44 LVL DESCRIPTION FIA97011 FIA ST Frame/Steel/Bolting/Welding PL Rough/Topout EL Rough Electric ME Rough/Ducts/Dampers ISSUED A ACT COMMENTS 7: '34 w I DATE 031898 031798 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 ***** INSPECTION DESCRIPTION ACT Rough Combo CA Rough Combo co Rough Combo co Rough Combo co Rough Combo CA Rough Combo CA Rough Combo CA Rough Combo NR Shear Panels/HD's AP Shear Panels/HD's CA Shear Panels/HD's PA Roof /Reroof PA Roof/Reroof CA T-24 H-Cap Consultation NS T-24 H-Cap Consultation NS T-24 H-Cap Consultation CA Underground Combo NS Frame/Steel/Bolting/Welding NR Rough Combo co Shear Panels/HD's co Underground Combo co Rough Combo co Shear Panels/HD's co Ftg/Foundation/Piers AP Frame/Steel/Bolting/Welding PA HISTORY INSP PK PK PK PS PK PK PK PK PK PS PK PK PY PK PK PK PK PK PK PK PK PK PK PK PY ***** COMMENTS SEE ATTACHED RESET FOR WED OR THURS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S & STRAPS OK CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/18/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : LOT: APPLICANT: SMITH, BART PHONE: 760 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP REMARKS: C/ RESET FROM TUES. 3/17 SPECIAL INSTRUCT: INSPECTOR e TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS \ 14 ST Frame/Steel/Bolting/Welding 24 PL Rough/Topout 34 EL Rough Electric 44 ME Rough/Ducts/Dampers -- -- - -- DATE 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 092597 072997 ***** INSPECTION DESCRIPTION Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD8s Shear Panels/HD8s Roof/Reroof Roof/Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation T-24 H-Cap Consultation Underground Combo Underground Combo Frame/Steel/Bolting/Welding Rough Combo Shear Panels/HD's Ftg/Foundat ion/Piers Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT co co CA CA CA co NR AP CA co PA PA CA NS NS CA co NS NR co co AP PA co AP HISTORY INSP PK PS PK PK PK PK PK PS PK PK PY PK PK PK PK PK PK PK PK PK PK PK PY PY PK ***** COMMENTS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S C STRAPS OK NO PLANS I CITY OF CARLSBAD *- NOTICE 490-3550 BUILDING DEPARTMENT DATE 9 -/$ TIME -A 2075 LAS PALMAS DRIVE %* PHONE CODE ENFORCEMENT OFFlCm c ' NOTICE 438-3550 ClK4 F CARLSBAD BU GDEPARTMENT 2075 LAS PALMAS DRIVE % f FOR INSPECTION CALL 438-3101. RE-INSPECTION FEE DUE? YES PHONE 68, COOEENFORCEMENTOmCER CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/17/98 DESCRIPTION: RAD 864 SF, BALCONY 150 SF TYPE: RAD JOB ADDRESS: 2125 BASSWOOD AV APPLICANT: SMITH, BART CONTRACTOR: OWNER: INSPECTOR AREA PK PLAWCKW CB971218 OCC GRP TYPE NEW STE : LOT: PHONE: 760 PHONE : PHONE : REMARKS: C/IDEAL CONSTR/438-0470 SPECIAL INSTRUCT: INSPECTOR 3 TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED FIA97011 FIA ISSUED CD 14 24 34 44 LVL DESCRIPTION ST Frame/Steel/Bolting/Welding PL Rough/Topout EL Rough Electric ME Rough/Ducts/Dampers + ***** INSPECTION HISTORY ***** DATE 031298 031098 030698 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 092597 072997 DESCRIPTION Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Roof/Reroof Roof/Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation T-24 H-Cap Consultation Underground Combo Underground Combo Frame/Steel/Bolting/Welding Rough Combo Shear Panels/HD's Ftg/Foundation/Piers Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT INSP CO PK co PS CA PK CA PK CA PK CO PK NR PK AP PS CA PK CO PK PA PY PA PK CA PK NS PK NS PK CA PK CO PK NS PK NR PK CO PK CO PK AP PK PA PY co PY AP PK COMMENTS REINSP FEE REQ (SEE ATTCH) TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S 61 STRAPS OK NO PLANS b CITY OF CARLSBAD PERMIT# CB971218 FOR 03/12/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : APPLICANT: SMITH, BART PHONE: 760 CONTRACTOR: PHONE : OWNER: PHONE : INSPECTION REQUEST OCC GRP REMARKS: C/IDEAL CONSTR/438-0470 SPECIAL INSTRUCT: TOTAL TIME: INSPECTOR --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 PATIO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST Frame/Steel/Bolting/Welding f&m* 24 PL Rough/Topout 34 EL Rough Electric 44 ME Rough/Ducts/Dampers zz. ,*,peCL-S ***** INSPECTION HISTORY ***** DATE ~ 031098 -030698 - 030498 -022798 022098 021098 012698 ' 012398 ,011998 -010998 .. 112697 -112497 411797 -111397 -110797 -110397 - 103097 - 111497 --11109 7 G:;; - 092697 - 092597 - 072997 DESCRIPTION Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Rough Combo Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Shear Panels/HD's Roof/Reroof Roof/Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation T-24 H-Cap Consultation Underground Combo Underground Combo Frame/Steel/Bolting/Welding Rough Combo Shear Panels/HD's Ftg/Foundation/Piers Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT INSP CA PK CA PK CA PK PK dk, PK AP PS CA PK CQ PK PA PY PA PK CA PK NS PK NS PK CA PK Cd PK 459 PS 43 E <e0 PK a/ PK AP PK PA PY AP PK G@ py COMMENTS TOO MANY CORR TO LIST/SEE ATT BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S & STRAPS OK NO PLANS CITY OF CARLSBAD NO PERMIT - STOP WORK - REMOVE CONSTRUCTION, OR OBTAIN PERMIT AND MAKE ANY READ REVERSE 0 WORK COMPLY WITH BUILDING LAWS. (see comments on reverse side regarding penalty fees). 0 CONSTRUCTION NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT - STOP WORK MAKE EXISTING WORK COMPLY WITH APPROVED PLANS AND PERMIT OR REMOVE IT. 0 CALL PLANING DEPARTMENT AT 438-1 161, CONCERNING VIOLATION OF ZONING REGULATION LISTED BELOW. VIOLATION NOTE: - PREQENT THIS NOTICE WHEN MAKINQ APPL~ATION FOR PERMIT 0 STOP WORK - UNTIL AUTHORIZED TO CONTINUE BY THE INSPECTOR. P _____ ~~ ~~ 0 CONTACT CODE ENFORCEMENT OFFICER AT 438-1 161. - u CONTACT INSPECTOR AND ARRANGE FOR APPOINTMENT AT 438-3550. CORRECTIONS USTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. @ PAY REINSPECTION FEE (See Back); THEN 0 CALL FOR REINSPECTION AT 438-3101. ph. CORRECTIONS REQUIRED I 0 PARTIAL APPROVED 0 WORK DESCRIBED BELOW HAS BEEN INSPECTED AND IS APPROVED. MUNICIPAL CODE REQUIRES PENALTY FEES WHEN WORK HAS BEEN STARTED WITHOUT PERMIT. ./ // m PLUMBING COMBINATION J INSPECTOR’S 8JQNATVRE OFFICETEL No DATE IN-I3 (Rev. 2/66) 200 A.M. TO 0:W A.M. 3:W P.M. TO 4SO P.M. Y CITY OF CARLSBAD BUILDING 1 X)BAM)REss I DEPARTMENT 0 OWNER. OR 0 CONTRACTOR VIOLATION READ REVERSE NO PERMIT - STOP WORK - REMOVE CONSTRUCTION, OR OBTAIN PERMIT AND MAKE ANY 0 WORK COMPLY WITH BUILDING LAWS. (See comments on reverse side regarding penalty fees). CONSTRUCTION NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT - STOP WORK MAKE EXISTING WORK COMPLY WITH APPROVED PLANS AND PERMIT OR REMOVE IT. NOTE SIDE -~ - PRESENT THIS NOTICE WHEN MAKING APPLICATION FOR PERMIT 0 CALL PLANING DEPARTMENT AT 438-1 161, CONCERNING VIOLATION OF ZONING REGULATION LISTED BELOW. 0 STOP WORK - UNTIL AUTHORIZED TO CONTINUE BY THE INSPECTOR. L)f) CORRECTIONS REQUIRED c] CONTACT CODE ENFORCEMENT OFFICER AT 438-1 161. c] CONTACT INSPECTOR AND ARRANGE FOR APPOINTMENT AT 438-3550. 0 CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. PPAY REINSPECTION FEE (See Back): THEN 0 CALL FOR REINSPECTION AT 438-3101. 0 PARTIAL APPROVED c] WORK DESCRIBE0 BELOW HAS BEEN INSPECTED AND IS APPROVED. ~~ THE ACTIONS OR CORRECTIONS INDICATED ABOVE ARE REQUIRED WITHIN, MUNICIPAL CODE REQYIRES PENALTY FEES WHEN WORK HAS BEEN STARTED WITHOUT PERMIT. DAYS. THE CARLSBAD IN-13 (Rev. 2/86) ROO A.M. TO A00 A.M. SW P.Y. TO 4- P.Y. MONDAY TWRU FMDAY ELECTRICAL X! I I PLUMBING I REFRIGERATION I! I CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/10/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 aA,SSWOOD AV STE : LOT: APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP REMARKS: C/IDEAL CONSTR/438-0470 INSPECTOR SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST 24 PL 34 EL 44 ME -7 -- -- Frame/Steel/Bolting/Welding Yi -jvt&Q c;isr Rough/Topout Rough Electric Rough/ Duct s/Dampers I ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 030698 030498 022798 022098 02109@ 01269a 012398 010998 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 092597 072997 *01199% t 112697 Rough Combo CA PK Rough Combo CA PK Rough Combo CA PK Rough Combo CO PK Rough Combo NR PK Shear Panels/HD8s AP PS Shear Panels/HD's CA PK Shear Panels/HD s CO PK Shear Panels/HD's PA PY Roof/Reroof PA PK Roof/Reroof CA PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation CA PK Underground Combo CO PK Underground Combo NS PK Frame/Steel/Bolting/Welding NR PK Rough Combo CO PK Shear Panels/HD8s CO PK Ftg/Foundation/Piers AP PK Frame/Steel/Bolting/Welding PA PY Frame/Steel/Bolting/Welding CO PY Ftg/Foundation/Piers AP PK BY RAY BY RAY 8AM 3/4/98 BY RAY HOLCOMB (SEE OVER) TOO WY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S & STRAPS OK NO PLANS I ‘Y CITY OF CARLSBAD NOTICE 430-3550 BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE DATE TIME * Lo& CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 03/06/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD E NEW JOB ADDRESS: 2125 BASSWOOD AV STE : APPLICANT: SMITH, BART PHONE: 760 753-2464 CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP REMARKS: C/IDEAL CONST/438-0470 SPECIAL INSTRUCT: INSPECTOR : TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTSA h 14 ST Frame/Steel/Bolting/Welding 24 PL Rough/Topout 34 EL Rough Electric 44 ME Rough/Ducts/Dampers DATE 030498 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 L 110397 5 103097 ;:::E; 3 092697 I 072997 % 092597 ***** INSPECTION DESCRIPTION ACT Rough Combo CA Rough Combo CA Rough Combo co Rough Combo NR Shear Panels/HD's co Shear Panels/HD's AP Shear Panels/HD's CA Shear Panels/HD's PA Roof/Reroof PA Roof/Reroof CA T-24 H-Cap Consultation NS T-24 H-Cap Consultation NS T-24 H-Cap Consultation CA Underground Combo NS Frame/Steel/Bolting/Welding NR Underground Combo co Rough Combo co Shear Panels/HD's co Ftg/Foundation/Piers AP Frame/Steel/Bolting/Welding PA Frame/Steel/Bolting/Welding CO Ftg/Foundation/Piers AP HISTORY ***** INSP COMMENTS PK BY RAY 8AM 3/4/98 PK BY RAY HOLCOMB (SEE OVER) PK TOO MANY TO LIST PK LEFT NOTICE W/SUPT. PS PK PK EXT SHEAR INCORRECT PY H.D.'S @ SHEAR WALLS PK PK PK PK PK PK PK PK PK PK PK PY PY PK RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S &I STRAPS OK NO PLANS PERMIT# CB971218 CITY OF CARLSBAD INSPECTION REQUEST FOR 03/04/98 DESCRIPTION: RAD 864 SF, BALCONY 150 SF TYPE: RAD JOB ADDRESS: 2125 BASSWOOD AV APPLICANT: SMITH, BART CONTRACTOR : OWNER: REMARKS: C/RAY/438-0470 SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE CB961350 m0 FIA97011 FIA CD LVL DESCRIPTION ACT 14 ST Frame/Steel/Bolting/Welding 24 PL Rough/Topout 34 EL Rough Electric 44 ME Rough/Ducts/Dampers 4 DATE 022798 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 092597 072997 INSPECTOR AREA PK PLANCK# CB971218 OCC GRP CONSTR. TYPE NEW STE : LOT: PHONE: 760 753-2464 PHONE : PHONE : INSPECTOR 1 STATUS ISSUED ISSUED COMMENTS W ***** INSPECTION HISTORY ***** DESCRIPTION Rough Combo Rough Combo Rough Combo Shear Panels/HD8s Shear Panels/HD8s Shear Panels/HD8s Shear Panels/HD8s Roof/Reroof Roof/Reroof T-24 H-Cap Consultation T-24 H-Cap Consultation T-24 H-Cap Consultation Underground Combo Underground Combo Frame/Steel/Bolting/Welding Rough Combo Shear Panels/HD' s Ftg/Foundation/Piers Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT INSP CA PK CO PK NR PK AP PS CA PK CO PK PA PY PA PK CA PK NS PK NS PK CA PK CO PK NS PK NR PK CO PK CO PK AP PK PA PY co PY AP PK COMMENTS BY RAY HOLCOMB (SEE OVER) TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S SI STRAPS OK NO PLANS CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 02/27/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCKI CB971ZL8 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE : LOT: APPLICANT: SMITH, BART PHONE: 760 CONTRACTOR : PHONE : OWNER: PHONE : OCC GRP REMARKS: C/IDEAL CONST/438-0470 SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 EO ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 24 PL Rough/Topout 1 34 EL Rough Electric 44 ME Rough/Ducts/Dampers 14 ST Frame/Steel/Bolting/Welding =z? -- - DATE 022098 021098 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 092597 072997 ***** INSPECTION HISTORY DESCRIPTION ACT INSP Rough Combo CO PK Rough Combo NR PK Shear Panels/HD's AP PS Shear Panels/HD's CA PK Shear Panels/HD8s CO PK Shear Panels/HD's PA PY Roof/Reroof PA PK Roof/Reroof CA PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation CA PK Underground Combo CO PK Underground Combo NS PK Frame/Steel/Bolting/Welding NR PK Rough Combo CO PK Shear Panels/HD's CO PK Ftg/Foundation/Piers AP PK Frame/Steel/Bolting/Welding PA PY Frame/Steel/Bolting/Welding CO PY Ftg/Foundation/Piers AP PK ***** COMMENTS TOO MANY TO LIST LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S t STRAPS OK NO PLANS CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 02/20/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCKB CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV APPLICANT: SMITH, BART CONTRACTOR: PHONE : OWNER: PHONE : OCC GRP STE : LOT: PHONE: 760 REMARKS: C/RAY/438-0470 AM PLEASE SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 24 34 44 ST Frame/Steel/Bolting/Welding PL Rough/Topout EL Rough Electric ME Rough/Ducts/Dampers ***** INSPECTION HISTORY ACT INSP NR PK DATE 012698, Shear Panels/HD's AP PS 012398. Shear Panels/HD's CA PK 011998 Shear Panels/HD's CO PK PA PY 112697 Roof/Reroof PA PK 112 4 9 74 Roof /Reroof CA PK 111797, T-24 H-Cap Consultation NS PK 111497. T-24 H-Cap Consultation NS PK 111397* T-24 H-Cap Consultation CA PK 111097. Underground Combo CO PK 110797 Underground Combo NS PK 110397' Frame/Steel/Bolting/Welding NR PK 103097. Rough Combo CO PK 101097 Shear Panels/HD's CO PK 101097) Ftg/Foundation/Piers AP PK 092697s Frame/Steel/Bolting/Welding PA PY 092597 s Frame/Steel/Bolting/Welding CO PY 021098, Rough Combo 010998. li- Shear Panels/HD's 072 997' Ftg/Foundat ion/Piers AP PK. ***** COMMENTS LEFT NOTICE W/SUPT. EXT SHEAR INCORRECT H.D.'S @ SHEAR WALLS RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S & STRAPS OK NO PLANS CITY OF CARLSBAD NO PERMIT - STOP WORK - REMOVE CONSTRUCTION, OR OBTAIN PERMIT AND MAKE ANY CONSTRUCTION NOT IN ACCORDANCE WITH APPROVED PLANS AND PERMIT - STOP WORK READ WORK COMPLY WITH BUILDING LAWS. (See comments on reverse side regarding penalty fees). 0 MAKE EXISTING WORK COMPLY WITH APPROVED PLANS AND PERMIT OR REMOVE IT. 0 CALL PLANING DEPARTMENT AT 436-1 161, CONCERNING VIOLATION OF ZONING 0 STOP WORK - UNTIL AUTHORIZED TO CONTINUE BY THE INSPECTOR. 0 VIOLATION a. REGULATION LISTED BELOW. NOTE - PRES T TW NOTICE WHEN I&&APPLICATK)N FOR PERMIT 0 CONTACT CODE ENFORCEMENT OFFICER AT 438-1 161. a CONTACT INSPECTOR AND ARRANGE FOR APPOINTMENT AT 438-3550. 0 CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED. c] PAY REINSPECTION FEE (See Back); THSN 0 CALL FOR REINSPECTION AT 438-3101. 0 WORK DESCRIBED BELOW HAS 6EEN INSPECTED AND IS APPROVED. 0 CORRECTIONS REQUIRED PARTI& APPROVED NCT /d5dM2 THE ACTIONS OR CORRECTIONS INDECATED ABOVE ARE REQUIRED WITHIN, MUNlClPAL CODE REQUtR& PENALTY FEES WHEN WORK HAS BEEN STARTED WITHOUT PERMIT. DAYS. THE CARLSBAD WILDING ELECTRICAL HEATINO PLUMING -- --.- ._ , REFRIGERATION 1 INSPECTOR'S BK)NA;TURE ORlQTEL No DATE 2 e 2%. -SF' IN-13 (Rev. 21m ROO A.M. TO 000 A.M. 31W P.Y. TO 4- P.Y. CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971218 FOR 02/10/98 INSPECTOR AREA PK DESCRIPTION: RAD 864 SF, BALCONY 150 SF PLANCK# CB971218 TYPE: RAD CONSTR. TYPE NEW JOB ADDRESS: 2125 BASSWOOD AV STE: CONTRACTOR : PHONE : OWNER: PHONE : OCC GRP APPLICANT: SMITH, BART PHONE: 760 REMARKS: C/CHRISTY/438-0470 SPECIAL INSTRUCT: INSPECTOR TOTAL TIME: --RELATED PERMITS-- PERMIT# TYPE STATUS CB961350 e0 ISSUED FIA97011 FIA ISSUED CD LVL DESCRIPTION ACT COMMENTS 14 ST 24 PL 34 EL 44 ME -- -- -- DATE 012698 012398 011998 010998 112697 112497 111797 111497 111397 111097 110797 110397 103097 101097 101097 092697 092597 072997 1, \ i \ 1 Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/ Ducts/ Dampers ***** INSPECTION HISTORY ***** DESCRIPTION ACT INSP COMMENTS Shear Panels/HD' s AP PS Shear Panels/HD's CA PK Shear Panels/HD's CO PK EXT SHEAR INCORRECT Shear Panels/HD's PA PY H.D.'S @ SHEAR WALLS Roof/Reroof PA PK Roof/Reroof CA PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation NS PK T-24 H-Cap Consultation CA PK Underground Combo CO PK Underground Combo NS PK Frame/Steel/Bolting/Welding NR PK Rough Combo CO PK Shear Panels/HD' s CO PK Ftg/Foundation/Piers AP PK Frame/Steel/Bolting/Welding PA PY Frame/Steel/Bolting/Welding CO PY Ftg/Foundation/Piers AP PK RESET FOR FRIDAY RESET FOR MONDAY STILL NOT PER PLAN LEFT NOTICE ON JOB CARD STEMS OK TO COVER HD'S & STRAPS OK NO PLANS CITY OF CARLSBAD NOTICE 430-3550 BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE @ BUILDING INSPECTOR CODE ENFORCEMENT OFFICEA EsGil corporation DATE: 7/11/97 JURIS D I CTI 0 N: Carlsbad PLAN CHECK NO.: 97-1218 PROJECT ADDRESS: 2125 Basswood Ave. PROJECT NAME: Collins Addition 0 IXI 0 0 0 IXI 0 0 MEVIEWER 0 FILE SET: I1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant‘s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: REMARKS: Mail Telephone Fax InPerson By: MifreKratz Enclosures: , Esgil Corporation 0 GA CM 0 EJ 0 PC 718197 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 t' - Carlsbad 97-12 18 I1 7/ 11/97 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 9. Handrai I s: a. The handgrip portion of all handrails s all be not less than 1-1/4 inches nor more than 2 inches in cross-sec nal dim sion. Handrails projecting from handrail. walls Section shall have 1006.9. at least a"..' 1- /2 n he tween the wall and the Handrails should be continuo s f the full length of the stairs. Section 1006.9. b. 12. For area of attic vents provided on p e 8 of the plans, I .2 of the vents must be provided by eave or cornice vents. DATE: 5/27/97 J U R I S D I CT I 0 N : Crvlsbad PLAN CHECK NO.: 97-1218 EsGil Corporatlon ProfmiodPGm Review Eyincers 0 FILE SET: I PROJECT ADDRESS: 2125 Basswood Ave. PROJECT NAME: Collins Addition 0 The plans transmitted herewith have been corrected where necessary and substantially comply 0 The plans transmitted herewith will substantially comply with the jurisdiction’s ********H codes with the jurisdiction’s *c**k**m* codes. when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IXI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant‘s copy of the check list has been sent to: DZN Partners, Bart Smith, AIA 682 Second St., Encinitas, CA 92024 IXI Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: Mail Telephone Fax InPerson 0 REMARKS: 2 By: Mike Kratz Enclosures: Esgil Corporation 0 GA 0 CM 0 EJ 0 PC 511 5/97 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (619) 560-1468 4 Fax (619) 560-1576 . . . ...= .. __ .-. _.... - - - -, ,; ., . ../ ,) .! - -. . .~ - . ;_. . . ._ , ,. .. ,_ , -_. .. . ,,__. . , _. .. , . , , , . . .. . . , . - ,. ...-. .- I . Carlsbad 97-1218 5/27/97 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 97-1218 JURISDICTION: Carlsbad PROJECT ADDRESS: 2125 Basswood Ave. FLOOR AREA: 864/2765 STORIES: 2 HEIGHT: 2 I REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 511 3/97 ESGIL CORPORATION: 5/15/97 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Mike Kratz DATE PLANS RECEIVED BY ~COMPLETED: 5/27/97 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994 UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process. please note on this list (or a COPY) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked UP list when you submit the revised plans. LIST NO. 1, GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forw.dot _. . ;: - -. . .. <, .. . ' . ,..I. . . .... Carlsbad 97- 12 18 5/27/97 PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1 161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1 468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Deliver all corrected sets of plans and calculations/reports directly to 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). e 3. Sleeping rooms shall have a window or exterior door for emergency escape. Sill height shall not exceed 44" above the floor. Windows must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools. Section 31 0.4. Bedrooms 2 & 3. 4. Window area must be at least 1 /I 0 of the floor area and a minimum of 10 square feet per Section 1203.3. At Bedroom 3, light and vent can not be taken thru the "Sun Room" 5. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. Bedrooms 2 & 3. Vent. can not be taken thru the Sun Rooms, Section 1203.3. 1 6. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1203.3. Master Bath. 7. For new skylights, specify the name of the manufacture, the model namehumber, and the IC60 or NER approval number. - Carlsbad 97- 12 18 5/27/97 0 EXITS, STAIRWAYS, AND RAILINGS 8. 9. IO. 11. 12. 13. 14. 15. Guardrails (Section 509.1): a) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6'. On stair sections on sheet 3, show 4" maximum between landing and bottom of guard rails, 6" is at stairs only. Handrails: a) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension. Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail. Section 1006.9. Handrails should be continuous for the full length of the stairs. Section 1006.9. b) ROOFING All structures require a Class B roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. California law requires that on or after July 1, 1995, every new structure have a fire retardant roof covering that is at least Class C. When 50% or more of the roof of an existing structure is reroofed within a one-year period, the structure shall have a fire retardant roof covering that is at least Class C. AB 3819. Show attic ventilation. Minimum vent area is 11150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. Note on the plans: corrosion-resistant metal mesh with mesh openings of 1 /4-inch in dimension." Section 1505.3. "Attic ventilation openings shall be covered with MECHANICAL (UNIFORM MECHANICAL CODE) Show that the existing FAU unit is adequate to heat the existing house to 70 degrees with the addition. If a larger unit is required, show that adequate combustion air can be provided. UBC 31 0.1 I, UMC Chapter 7. ELECTRICAL (NATIONAL ELECTRICAL CODE) Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. .. . ..-. . .- -.._ , . . .._ .~_-_*~.-.,. ..-..,-- -...- - ...-.. _.. .-. ^.. - ,,.......,.. , ,II_ _.___ 1_ ._ . ,. ... -. . . . -, Carlsbad 97- 12 18 5/27/97 0 PLUMBING (UNIFORM PLUMBING CODE) 16. Show that water heater is adequately braced to resist seismic forces. Provide two straps (one strap at top 113 of the tank and one strap at bottom 1/3 of the tank). UPC, Section 510.0 17. Provide a note on the plans: In showers and tub-shower combinations, control valves must be pressure balanced or thermostatic mixing valves. UPC Section 41 0.7 18. New water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard AI 12.1 9.2. H & S Code, Section 17921.3(b). ENERGY CONSERVATION 19. Specify on the buildina plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". 20. Provide a note on the plans stating "All new glazing (fenestrations) will be installed with a certifying label attached, showing the U-value." 21. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms. CARLSBAD S.F.D. & DUPLEX SUPPLEMENT 22. All new residential buildings, including additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. FRAMING 23. Per UBC Section 2343.6, provide the following note on the plans if trusses are used: "Each truss shall be legibly branded, marked or otherwise have permanently affixed thereto the following information located within 2 feet of the center of the span on the face of the bottom chord: a) b) The design load. c) Identity of the company manufacturing the truss. The spacing of the trusses." 1 Carlsbad 97-1218 5/27/97 24. 25. 26. 27. 28. 29. 30. Show location of attic access with a minimum size of 22mDx30', unless the maximum vertical headroom height in the attic is less than 30. Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 1505.1. Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2317.5. 0 FOUNDATION REQUIREMENTS Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan. Section 1806.6. MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, Le., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. 0 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of 6191560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Kratz at Esgil Corporation. Thank you. . Carlsbad 97-1218 5/27/97 BUILDING PORTION VALUATION AND PLAN CHECK FEE BUILDING AREA VALUATION VALUE (ft.*) MULTIPLIER ($) JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1218 Air Conditioning Fire Sprinklers TOTAL VALUE Per Application PREPARED BY: Mike Kratz DATE: 5/27/97 $82,866.00 BUILDING ADDRESS: 2125 Basswood Ave. BUILDING OCCUPANCY: R-3/U- 1 TYPE OF CONSTRUCTION: V-n 1991 UBC Building Permit Fee 1991 UBC Plan Check Fee 0 Bldg. Permit Fee by ordinance: $ 563.00 0 Plan Check Fee by ordinance: $ 365.95 Type of Review: (x1 Complete Review 0 Structural Only 0 Hourly 0 Repetitive Fee Applicable 0 Other: Esgil Plan Review Fee: $ 292.76 Comments: 1 Sheet1 of 1 macvalue.doc 5196 ... ....... .... I -.-- , , -7 , . I, , . ;. . -- .... ... ... ., . >.:. I .. . " BUILDING PLANCHECK CHECKLIST DATE: 5/22 /./ 7 PLANCHECKNO.: CB 97- \z r%' BUILDINGADDRESS: 2125- &$jaoock &e. . ASSESSOR'S PARCEL NUMBER: ;e' PROJECT DESCRIPTION: R4S. add6 20 5 - 1.60 * 2 \ EST. VALUE: g2,866 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-way permit is required prior to construction of the following improvements: I DENIAL Please see attached report of deficiencies ake necessary corrections to plans for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. BY: s2 Date: 7/7/77 By: Date: - "E FOR OFFICIAL USE ONLY n ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON Dedication Application Dedication Checklist Improvement Application Improvement Checklist Name: David Rick City of Carlsbad Future Improvement Agreement Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Grading Permit Application Grading Submittal Checklist Right-of-way Permit Application Right-of-way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet Phone: (619) 438-1161, ext. 4324 'VWWW~~.c~~f~BE CA 9200971 576 0 (61 9) 438-11 61 FAX (61 9) m-94 '\ ISp(" P P BUILDING PLANCHECK CHECKLIST SITE PLAN 3Rw P 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow Property Lines Existing & Proposed Structures Easements &+ 8 ' wb\;~ Jti I;+) esse*+ Driveway widths pW+ 4-1- rcar ight-of-Way Width & Adjacent Streets bc C. Existing Street Improvements 0 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography 0 3. Include on title sheet: A. Site address B. Assessor's Parcel Number c- Legal Description LO+ 9 , @e IladaAAt. t.14 j uy; .)- I 345~ For commercial/industriaI buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION DISCRETIONARY APPROVAL COMPLIANCE Q 5. Project does not comply with the following Engineering Conditions of approval for Project No. 0 6. All conditions are'in compliance. Date: * BUILDING PLANCHECK CHECKLIST DEDICATION REQUIREMENTS 7. Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for & new buildings and for remodels with a value at or exceeding $ , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 w" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner@) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS CI CI CI 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ , pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: 8b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent t~ 'tle report gr we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: ji ~~uL<J) prrent arant d& on the property and processing fee of $ !30,00 so S; &YJQ Ik &$ . I rp””’ BUILDING PLANCHECK CHECKLIST IU P‘ 3w P P P 8c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: P P P 8d. No Public Improvements required. SPECIAL NOTE: Damaaed or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 1 I .06.030 of the Municipal Code. P P P 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). P 0 P 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Gradina Permit must be issued and rouah arading approval obtained prior to issuance of a Buildinn Permit. Grading Inspector sign off by: Date: P 0 P 9c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) Cl 9d. No Grading Permit required. MISCELLANEOUS PERMITS P P P 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or private work adjacent to the public Right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-way permit required for: BUILDING PLANCHECK CHECKLIST 0 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Pk Industrial Waste permit accepted by: Date: BK CI CI 13. NPDES PERMIT / Complies with the City’s requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. P 1% CI equired fees are attached do fees required dP 0 0 0 15. Additional Comments: I DOC t iws-0203732 15-HAY-1995 12826 PH 5 Sipnrhrr (SEAL) CU-2U-4-UIMOS 1-11 P8p 4 Of 4 .. RECORDING REQUaTED BY: WAW!& mui wm *I 'WHEN RECORDED MAIi TO FRONTLINE MORTGAGE COMPANY 1063 MCGAW, SUITE B IRVINE, CA 92714 Loan Number t 20013709-9 _-- DOC li 1992-0424351 07-JUL-1992 12rS2 PM DEED OF TRUST THIS Dm OF TRUST c scauity Imaumsnt") fr nude on' June $4, 1992 Tlwmtoria FLOYD EUGENE COLLINS and ELAINa M. COLLINS, HUSBAND AND WIFE (Tkmmmf).Th@trrrweir (7tuams 7b6 bemild8ry Is RESIDENTIAL RECONVEYANCE SERVICES, A CALIFORNIA CORPORATLON PSF MORTGAGE LIMITED, A LIMITED PARTNER$HIP, DBA FRONTLINE MORTGAGE COMPANY which b organimed and existing under the hwr of CALIFORNIA , rad Vhors 8- b 1063 MCGAW, SUITE B, IRVINE, CA 92714 (%end&). Bomrwor oam) Lander tbe princ@al SWI of NINETY-FIVE THOUSAND DOUARS AND 00/100 ALL THAT CERTAIN REAL PROPERTY AS MOW PARTICULARLY DESCRIBED ON EXHfBIT A ATTACHED HERETO AND MADE A PART HEREOF which has the addrev of 2 12 5 BASSWOOD AVENUE [S-4 CARLSBAD wtyl i’ I' STATE OP 'CALIFORNIX i131 , . CITY CS CARLSBAD .... I. . .. t. .. .. 0'. .. .. .. .. , .. .. ,.. .... .. . _I . -.. .. ....... .... Lot 9 of BELtLAOdNNA HBIQWTS WIT NO, 1 in tho City of' Carlrbad, County of San Diego, State of California, accordid Auguert 29, 1958. to Ma thereof No. 3955, filed in ehe OZFlce of the County Recorder o !! 8an D P ego County, b.. ' I .. y1I .. .............. .. ... ... . , I. . -7 ..- ,...- -*-- ~ ...._ t'.. >' .. I .' *. .. I. ...... ... .. .. ... .: . . .... .. . 1. .. .. .. ..... .. ... ........ .:. ... .. .. ... ... .... .... .... i . .. . . * . . , ::. .* I '. . . . 1, ... .. ..... ....... .. 8.. :. ' : . , ,.: ..... .... , .. , . , , *.':., ' ' .. ................ .. ... ......... ,. ..r::\, . :,: , ,. ,.:. . ' .. ar.. .... I >>', .;. . ........ ... ; .,.,,> '? *. ... ..... .. I I . TITLE*COMPANY Los ANQELES OFFICE 20350 Ventura Blvd., Suite 200 Woodland Hills, CA 91364 Office (SOO) 743-7701 Customer Service (SOO) 927-0037 PLAT MAP ORANQE COUNTY OFFICE 1320 S. Sanderson Avenue Anaheim, CA 92806 Office (714) 776-4900 Customer Service (714) 385-1344 SAN MEW OFFICE 1660 Hotel Circle North, Suite 321 San Diego, CA 92108 Office (800) 347-2002 Customer Service (800) 540-3675 .I s! d k (v 4 00 i CE dh PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Address Planner Grea Fisher Phone (61 9) 438-1 161, extension 4328 APN: Zone: p-1 - 10 Facilities Management Zone: I 66 -2 4 Type of Project and Use: 5clc / I (If property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) CFD Circle (i'T ne Leaend Item Complete Item Incomplete - Needs your action - ,OFTYPE 5 Environmental Review Required: YES DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YESDATENO - TYPE APPROVAL/RESO. NO. PROJECT NO. OTHER RELATED CASES: Compllance with conditions or approval? If not, state conditions which require action. Conditions of Approval Coastal Zone AssessmentICompliance Project site located in Coastal Zone? If California Coastal Commission Authority: Contact them at - 31 11 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES- NO- If NO, complete Coastal Permit Determination Form now. YES - CA Coastal Commission Authority? YES - NO- Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. UUU (Effective date of lnclusionary Housing Ordinance - May NL3., 2 lnclusionary Housing Fee required: YES - NO Date Entry Completed? YES - Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and Zoning: 1. 2. assessor's parcel number. Set backs: Front: Int. Side: Street Side: Rear: Shown 2-7 Required W - Required 7. >- Shown 71-F Shown - Required 7 Required Shown 15' Accessory Structure Setbacks: Front: 3. Lot Coverage: Required 646 Shown 4. Height: XY Required f: -= ' Shown Shown 7 Shown - 5. Parking: Spaces Required L- / Guest Spaces Required Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE $(fq c c c c - c c .- c .- c BARRY AND ASSOCIATES GEOTECHNICAL ENGINEERING P.O. Box 230348 Encinitas, CA 92023-0348 (61 9) 753-9940 June 30, 1997 Floyd and Elaine Collins 2125 Basswood Avenue Carlsbad, California 92008 Att: DZN Partners, Bart M. Smith, Architect 682 Second Street Encinitas, California 92024 Subject: PRELIMINARY GEOTECHNICAL INVESTIGATION Proposed Addition To A Single Family Residence 2125 Basswood Avenue Carlsbad, California 92008 Dear Mr. and Mrs. Collins, In response to your request, we have performed a preliminary geotechnical investigation at the subject site for the proposed addition to the single family residence. The findings of the investigation, laboratory test results and recommendations for grading and foundation design are presented in this report. From a geotechnical point of view, it is our opinion that the site is suitable for the proposed additions to the residence, provided the recommendations in this report are implemented during the design and construction phases. If you have any questions, please contact us at 753-9940. This opportunity to be of service is appreciated. Respectfully submitted, A.R. BARRY AND ASSOCIATES c c c c c c c c PRELIMINARY GEOTECHNICAL INVESTIGATION Proposed Addition To A Single Family Residence 2125 Basswood Avenue Carlsbad, California Prepared For: Floyd and Elaine Collins 2125 Basswood Avenue Carlsbad, California 92008 June 30, 1997 W.O. P-1509 Prepared By: P.O. Box 230348 Encinitas, CA 92023-0348 A.R. BARRY AND ASSOCIATES c c c c c c c TABLE OF CONTENTS INTRODUCTION ................................................ 2 SITE CONDITIONS ............................................. 2 PROPOSED DEVELOPMENT ........................................ 2 SITE INVESTIGATION .......................................... 2 LABORATORY TESTING .......................................... 3 GEOTECHNICAL CONDITIONS ..................................... 3 CONCLUSIONS AND RECOMMENDATIONS ............................. 3 A. GENERAL ................................................ 4 B. FOUNDATION ....................................... 4 E. DRAINAGE .......................................... 4 F. FOOTING INSPECTION ............................... 5 G. PLAN REVIEW ....................................... 5 LIMITATIONS ................................................. 5 June 30, 1997 Page 2 W.O. #P-1509 + c c c c c INTRODUCTION This report presents the results of our preliminary geotechnical investigation. The purpose of this study is to evaluate the nature and characteristics of the earth materials underlying the property and their influence on the proposed additions to the residence. SITE CONDITIONS The rectangular lot is located on the south side of Basswood Avenue between Belle Lane and Donna Drive in Carlsbad, California. The lot contains a single story residence and garage. PROPOSED DEVELOPMENT Plans for the addition residence were prepared by DZN Partners, Bart Smith, Architect of Encinitas, California. The plans provide for a second story addition to the residence and alterations to the first floor. SITE INVESTIGATION The investigation consisted of visual observation of the property including site drainage, topographic conditions, soil conditions and types, and the potential expansion of on-site soils. June 30, 1997 Page 3 W.O. #P-1509 c c c c c c LABORATORY TESTING Classification The field classification was verified through laboratory examination in accordance with the Unified Soil Classification System. The final classification is shown on the enclosed Logs. GEOTECHNICAL CONDITIONS Soil Native soil consists of brown to gray silty sand of the formational sandstone deposit typical of the area. Expansive Soils All soils encountered in our field investigation have an expansion potential in the low range. Liquefaction The soils on the site are not considered subject to seismically induced soil liquefaction and soil instability due to such factors as soil type, density and lack of groundwater. CONCLUSIONS AND RECOMMENDATIONS General The on site soils are suitable for the support of the proposed addition to the residence provided the recommendations in this report are implemented during the design and construction phase. Y c c June 30, 1997 Page 4 W.O. #P-1509 c c c L c c c c c c c c c Foundation General Loads from the proposed second story addition should be transferred to new footings in lieu of utilizing the existing footings. Footings for the proposed second story addition should be a minimum of 12 inches wide and founded a minimum of 18 inches below grade. Footings founded a minimum of 18 inches below grade may be designed for a bearing value of 2000 psf. The bearing value indicated above is for the total of dead and applied live loads. This value may be increased by 33 percent for short durations of loading, including the effects of wind and seismic forces. Resistance to lateral load may be provided by friction acting at the base of foundations and passive earth pressure. A coefficient of friction of 0.3 should be used with dead-load forces. A passive earth pressure of 250 pounds per square foot, per foot of depth of fill penetrated to a maximum of 2000 pounds should be used in the design. Drainaqe All roof water should be collected and taken to the Street via non- erodible device. Padwater should be directed away from foundations and around the residence to a suitable location. Pad water should not pond. Roof gutters are recommended. f- June 30, 1997 Page 5 W.O. #P-1509 c c- c c Footinu Inspections Structural footing excavations should be inspected by this firm during excavation. Final depth of footings will be determined at that time. Plan Review A copy of the final building plans were reviewed by this office and found to be in compliance with the provisions of this report. LIMITATIONS This report is presented with the provision that it is the responsibility of the owner or the owner's representative to bring the information and recommendations given herein to the attention of the project's architects and/or engineers so that they may be incorporated into the plans. If conditions encountered during construction appear to differ from those described in this report, our office should be notified so that we may consider whether or not modifications are needed. No responsibility for construction compliance with design concepts, specifications or recommendations given in this report is assumed unless on-site review is performed during the course of construction. The conclusions and recommendations of this report apply as of the current date. In time, however, changes can occur on a property CERTIFICATE OF COMPLIANCE CITY OF CARLSBAD COMMUNITY DEVELOPMENT 2075 LAS PALMAS DR., CARLSBAD, CA 92009 Plan Check No. (61 9) 438-1 161 This form shall be used to determine the amount of school fees for a project and to verify that the project applicant has complied with the school fee requirements. No building permits for the projects shall be issued until the certification is signed by the appropriate school district and returned to the City of Carlsbad Building Department. SCHOOL DISTRICT: )( Carlsbad Unified 801 Pine Avenue Carlsbad CA 92009 (434-066 1 ) Encinitas Union 101 South Rancho Santa Fe Rd. Encinitas CA 92024 (944-4300) San Marcos Unified 1290 West San Marcos Blvd. San Marcos CA 92024 (744-4776) San Dieguito Union High School 71 0 Encinitas Boulevard Encinitas CA 92024 (753-6491) Project Applicant: APN??*S -- -[do- z/ Project Address: [%5 Z&s+f&OOd A!& number of dwelling units SQ. FT. of garage area SQ. FT. of covered area \ Date SQ. FT. of living area COMMERCIALAN DUSTRISSQ. FT. AREA Prepared by - RES I DEN TIAL: FEE CE RT I F I CAT ION (To be completed by the School District) X Applicant has complied with fee requirement under Government Code 53080 Project is subject to an existing fee agreement Project is exempt from Government Code 53080 Final Map approval and construction started before September 1, 1986. (other school fees paid) Other Residential Fee Levied: $ 1589 76 based on $64,: sq. ft. @ $1.84 Comm/lndust Fee Levied: $ based on sq. ft. @ I ASST. SUPT. BUSINESS SERVICES 7-4-97 Sc h'd D i str i c Title Date BUILDING PERMIT PCR No: PCR98008 03/06/9d 11: 19 Project No: A9701586 Page 1 of 1 Development No: Job Address: 2125 BASSWOOD AV Suite : Permit Type: PLAN CHECK REVISION Parcel No: 205-160-21-00 Lot#: Valuation: 0 Cod~~fkWR~dl N6aJ Description: REVISION-ADDING STAIRS TO BACK Applied: 01/26/98 : PATIO Apr/Issue: 03/06/98 I Occupancy Group: Reference#: SlfdfEr: ISSUrn~ Entered By: JM Appl/Ownr : SMITH, BART 760 753-2464 682 2ND STREET Adju Tot Fe Plan ----- Fees R -------- Fees : stments: a1 Fees: e descri Check R -------- ENCI .equi ptio .evis ---- I FINAL~APPROVAL I CITY OF CARLSBAD 2075 Las palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPLICATION FOR OFFICE USE I PLAN CHECK NO. CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 \ (760) 438-1 161 Address (include BldgISuite XI Business Nama EST. VAL. Plan Ck. Deposit d Validated By Date I U Legal Description Lot No. Subdiiim NameMumber Unit No. Phase No. Total t of units .. Assessor's Parcel t Existing Use Proposed Use t of Bedrooms 1 of Bathrooms Address statmp Telephone I Name Nsme Address ci TeleDhone t ISec. 7031.5 Business and Professions Code: Any Ci or County which requires a permit to construct, alter, improve. demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrector's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he ie exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1b5001). Name Address ci statmp Telephone I State License t License Cless Ci Businem License I Designer Name Address Cltv StatdLip Teiephone State License I Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 of the work for which this permit is issued. 0 issued. My worker's compensation insumnce carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUN- DOUARS ($1001 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for whiih this permit is i8sued, I ahall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California. WARNING: Fdh to aoum worlm' wmpaudm ~omg. b unhwful, and 8hdIrubi.a n .mpkyr to crlmlnd pondUn and dvl fhw ~lp to ona kudnd thouMnd ddkn lbl00.000). In .dditbn tothe cost of v. d.nug.l am P0vid.d for In 8.ctbn 3706 oftha L.ba cod., intamat and attonmy's t..r. I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, es required by Section 3700 of the Labor Code, for the performance of the work for whlch this permlt is I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for de (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an own^ of property who build# or improves thereon, and who don such work himself or through his own employees, provided that such improvements are not intended or offered for s8k. If, however, the building or improvement ia sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the pupore of ah). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Set. 7044, Burinass and Professions Code The Contractor's Licenae Law does not apply to an owner of property who buikk w improves thereon, and contracta for euch projects with comnctor(s) lim pursuant to the Contractor's License Law). 0 1. 2. 3. I am exempt under Section I personally plan to provide the major labor and materials for cDMtruaMn of the proposed proparty improvoment. 0 YES ON0 I fhava / have not) signed an application for a building permit for the propoud work. I have contracted with the following person (firm) to provide the pmposed CaMRlCtion (ii& name / addmas / phone number / contractors license numbar): Businms and Professions Code for thk reaaon: 4. number I contractors license number): 5. of work): PROPERTY OWNER SIGNATURE DATE I plan to provide portions of the work, but I have hired the following person to coordinate. supervise and provida the major work (include name I address I phone I will provide some of the work, but 1 have contracted (hired) the following POMOM to provide the work indiied findude name / address / phone numbsf I type program under Sections 25505,25533 or 25534 of the Wey-Tanner Hazardaw Substance Account Act? 0 YES 0 NO Is the applicant or future building occupent required to obtain a pennit from the air pollution control diswict or alr quality managament dmrict? Is tho facility to be constructed within 1 ,OOO feet of the outer boundary of a schoof site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A RNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPUCANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POUUTDN CONTROL DISTRICT. 0 YES 0 NO I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is hued (Sac. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is come13 and that the information on the plans k accurate. I agree to comply with ell City ordinances and State laws relating to building construction. I hereby authorize repm8entatives of the ckt of Ca-d to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST AIL WUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demdion or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the work authorized by such permit is not or abendoned at any time after t r the provisions of this Code shall expire by limitation and become null and void if the building-or 65 days from the date of such permit or if the building or work authorized by such pennit is suspended r a period of 180 days (Section 106.4.4 Uniform Building Code). 4Ah.lCANT'S SIGNATURE DATE I- zd-?g h WHITE: File YELLOW Applicant PINK: Finance ~~~ EsGil Corporation DATE: 2/5/98 JURISDICTION: Carlsbad 12 FILE PLAN CHECK NO.: 97-1218/PCR98-008 SET: I PROJECT ADDRESS: 2125 Basswood PROJECT NAME: Collins Residence [7 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at Esgil 0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant Corporation until corrected plans are submitted for recheck. contact person. 0 The applicant‘s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: REMARKS: Add notes penned on approved sets on pages 3 and 8 to revisions sets. On stair detail, show a 1 1/2” to 2 1/4 grippable handrail. Detail 3/11 shows flat 2x6. Mail Telephone Fax In Person By: MikeKratz Enclosures: Esgil Corporation GA CM EJ PC I /29/98 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1218/PCR98-008 PREPARED BY: Mike Kratz BUILDING ADDRESS: 2125 Basswood Rev. #1 BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: DATE: 2/5/98 B U I L D I N G P 0 RTI 0 N BUILDING AREA VALUATION VALUE (ft.*) MULTIPLIER ($) ' Air Conditioning Fire Sprinklers - TOTAL VALUE 199 UBC Building Permit Fee 199 UBC Plan Check Fee Type of Review: Complete Review Structural Only Hourly 0 Repetitive Fee Applicable c] Bldg. Permit Fee by ordinance: $ Plan Check Fee by ordinance: $ Other: Esgil Plan Review Fee: $ 43.57 Comments: 1/2 hr. x $87.15 = $43.57 Sheet1 of 1 rnacvalue.doc 5196 SHEETNO: /Lj3 San Diego, CA 92110 - Lu- -_)c-7&&-& ZbW 3 L1k L ,&,&la Y L PROJECTNO: SHEETNO zx San Diego, CA 92110 Ph (619) 224-2855 Fax (619) 224-6747 ,. 0 -- I Ph (619) 224-2855 Fax (619) 224-6747 I BY: //P/98 . I. ., I 1. ‘. r. c PROJECTNO: Ph (619) 224-2855 Fax (619) 224-6747 z9'94 .. PROJECT NAME: . PROJECT NO %-- San Diego, CA 92110 PLANNING/ENGINEERlNG APPROVALS RESIDENTIAL __c___ RESIDENTIAL ADDITION MiNOR . L TENANT IMPROVEMENT PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING C:\WP5 1 \FILES\BLDG.FRM Rev 1111 5190 ti U I L ii I N G P E R M I T PCR NL) : PCR3 7 U 9 2 12/zj/'Y7 rJ8: 59 Pr~ject Nc~: A97(115aIs Paae 1 of 1 Development No : Jr1t.s Address: 2125 EASSWOOD AV Suite: Permit Tvpe: FLAN CHECK REVISION Parcel 140: 2o5-li3u-21-UO Lot#: 2499 12/23/77 0001 01 02 Valuation: 0 Construction @w: NEW 55-00 Occupancy Group : Reference#: CB971218 Status: ISSUED Eescription: REVISION-FOUNDATION STRAP & Applied: 11/21/97 : FLOOR FRAMING POST BEAM CONNECTIONS Apr/Issue: 12/23/97 I Entered BV: JM AppI/Ownr : SMITH, BART 760 753-2464 682 2NLi STREET ENCINITAS, CA 92024 AA* Fees Keyuired *** *** Ad!ustments : . 0 0 ______I___-_------ Fees : Total Fees: . u 1.) 55.00 Fee description Ext fee Data ___________------- ----_-_----------- Pian Check Hevisi 55,OU b FINAL AJPPROVAL CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 c FOR OFFICE USE OALY PERMIT APPLICATION I PLAN CHECK NO./d/?y7% CITY OF CARLSBAD BUI 2075 Las Palmas Dr., Car (760) 438-1 161 ., A Proposed Use X of Bedrooms as - \Go - 2C SFk Assessor's Parcel t Existing Use Description of Work t of Bathrooms Name Address ci Statelzip Telephone X Fax 1 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permt to file a signed stetement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending wth Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars l$5001). Name Address City Statelzip Telephone X State License # License Class City Business License # Designer Name Address City StatelZip Telephone State License t 0 of the work for which this permit is issued. 0 issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Data (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS I81001 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any parson in any manner so as to become subject to the Workers' Compensation Laws of California. WARNINQ: Failure to aecure workers' compensation coverage Is unlawful. and .hd( subject an employer to criml~I pe~lties and dvil fine8 up to 01). hundred thousand dollars (8100.000~. In addition to the cost of compensation. damngas as provided for in Section 3706 of the Labor code, interest and attomy's fees. I have and will maintain a certificate of consent to self-insure for workers' compensation as providad by Section 3700 of the Labor Code, for the performanca I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as ownar of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an ownar of property who builds or improves thereon, end who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement ia sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number I contractors license numbar): Business and Professions Code for this reason: 4. number / contractors license number): 5. of work): PROPERTY OWNER SIGNATURE DATE I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / eddress I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE 0 YES 0 NO I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I egree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit) of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABIUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep end demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official undar the provisions of this Code shall expire by limitation and become null end void if the building or work authorized by such ta of such permit or if the building or work authorized by such permit is suspended or abandoned et any time (Section 108.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE 19-7 WHITE: File YELLOW: Applicant PINK: Finance - EsGil Comoration I ProfessiodPh Review Eryinccrs DATE: 12/4/97 JURIS D l CTl ON : Carlsbad mNT WEVIEWER 0 FILE PLAN CHECK NO.: 97-1218 PCR 97-92 SET:I Rev#l PROJECT ADDRESS: 2125 Basswood Ave. PROJECT NAME: Collins Addition la 0 0 0 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant‘s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: REMARKS: Revised sheets must be signed by the architect. Mail Telephone Fax In Person By: MikeKratz Enclosures: Esgil Corporation GA CM 0 EJ 0 PC 11/24/97 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 BUILDING PORTION Carlsbad 97-1218 PCR 97-92 12/4/97 VALUATION AND PLAN CHECK FEE rev. #I BUILDING AREA VALUATION VALUE (ft.*) MULTIPLIER ($) JU RlSD ICTION: Carlsbad 92 PLAN CHECK NO.: 97-1218 PCR 97- PREPARED BY: Mike Kratz DATE: 12/4/97 BUILDING ADDRESS: 2125 Basswood Ave. PCR 97-92 BU I LD I NG OCCUPANCY: TYPE OF CONSTRUCTION: Air Conditioning Fire Sprinklers I I I TOTALVALUE I ~ ~ 0 199 UBC Building Permit Fee c] 199 UBC Plan Check Fee Type of Review: Complete Review 0 Structural Only Hourly 0 Repetitive Fee Applicable [7 Bldg. Permit Fee by ordinance: $ [7 Plan Check Fee by ordinance: $ Other: Esgil Plan Review Fee: $ 43.58 Comments: 112 hr. x $87.15 = $43.58 Sheet1 of 1 macvalue.doc 51 96