HomeMy WebLinkAbout2131 PALOMAR AIRPORT RD; ; CB973828; Permit-3,3
B UI L.D I N-G P E RM I T . Permit No: CB973828
05118/98 11:54 Project No: A9704941
Page 1 of 1 '-. . -Dev&lopment .No:
'Job Address: 2131 PALOMAR AIRPORT RD' Sute:
Permit Type: COMMERCIAL TENANT-IMPROVEMENT *
Parcel. No: 213-070-2700 .. -. ' Lot#:
I Valuation: 26,000 . - Construction Type: NEW
I
Occupancy Group: - . Reference#: - . Status: ISSUED
Description: CTI LOBBY- REMODEL1000 SF ' - Applied: 12/17/97
-
- - ' Apr/Issue: 05/18/98
- - . - Entered By:. JM4
Appl/Ownr-: WHARTON LARRY. - ' :61 203-1773 -
639 BISON COURT -. •. ' . - EL CAJON CA 92019
Fees Req.tired **4. - Collect 0&057t'd&iO1 01 02**
------------------------ ---------- =1_1_____i5000
'Fees: 518.(
Adjustments: - /00 , '-crL,rd1t .09
Total Fees: 51,8.00 \J Tota1LPame'n-ts: -168.00
S350. 00
Fee description Ext fee Data W
Building Permit 259.00
-Plan Check
Strong Motion Fee 5.00
'Gas Piping System 7. 0 7'.00
Remodel/Alter Pe A .25 25, 00
INCORPORATED
1952
FINAL APPRQVAL VAL,
77
*
ID
CLEARANCE
.1 4 ' CITY OF CARLSBAD
2075 Las Palmas Dr, Carlsbad CA 92009 (619) 438-1161
' J3 FOR OFFICE USE ONLY
PERMIT APPLICATION PLAN CHECK NO ?75Y2,119e
CITY OF CARLSBAD BUUDINa DEPARTMENT '
ET. VAL.'__________________
2075 Las Palmas Dr, Carlsbad CA 92009 Plan Ck Deposit /
(760) 438-1161 - Validated By'- /
Date2404 17/j,/97
.
. 168O
Address (include Bldg/Suite #)
S -Business Name (at thisjddress), .
Legal. Description '-- Lot No. Subdivision Name/Number Unit No Phase No. Total # of units
Assessors Parcel # Existing Use Proposed Use
Description of Work SQ. FT.- #of Stories # of Bedrooms ' .# ofBathrooms
" _S4 = - - _-, ~J )m
I ~NT % T-f~, il WRO NA I f, i; §htrf"r.6_x1b1.0Di
-5 9
Name -. .- Address . Ci ty State/Zip Tephona F Fax #
OnTj ent tor O,-. m r
Name .. ..•. Adclress/ hf C State Z. —phone # - . t..........................................
Name Addres Sty State/Zip Telephone #
.[5c:oNTMR;PMPANVk .. 1' JL .L
(Sec. 7031.5 Business and Professions Code: Any ,City or County which requires a permit to construct, alter,imprve,.demoIisi orrepau. any structure, prior to its
'issuance, 'also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he he is exempt therefrom, and.t basis for the alleged exemption. Any 70 y any aPPlic itsubiects th)l7 nttoacivil penalty of nol~iqlo than eF?than fi d dollars 1$5001).
Name if Address " :. City r " '. State/Zip .1 . Telephone #'
State License # .2-rjT License Class tVinessi:iceisi'#. ( Q H5
Designer Name , Address . . City, •. ' State/Zip Telephone .
State License
E6WORKERSçOMPENSATION — 1'
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
'0 I, have and will maintain acertificate of onsent to self-insure for workers' compnsation as provided by-Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - -
0 I have and will maintain workers' compensation, as required .by Section 3700 of the Labor Code, for the performance of the work for which this permit is
.issued. My worker's
Insurahce Company ornPesat umberare:
.Polici' No. 7Vz F Expiration Date ' /8
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONEHUNDRED DOLLARS [$1001 OR LESS) :
ID CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is isued,l shall not emp!y any person in any manner so as
to becoiie subject to the Workers' Compensation Laws of California . .
WARNING: Failure to secure workers' compensation covera unlawful,and shall subject an employer to criminal penalties and civil fines up to one hundred
-Ihousand dollars (8100.000), in addition to the Co nsation, da fo. In Section 3706 of the Labor c de,tinterest and attorney's fees.
GNATU - ' 'S •' -
-
'I hereby affirm that I am exempt from t ntractor's License Law for the following reason: E] I as owner of the property or my empl'yees with wages as their sole compensation will do the work and the structure is not intended or, offered for sale (Sec. 7044; Business and Professions Code: The Contractor's License Law does not apply.to an owierof property who builds or, improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one .year of completion, the owner-builder will have the burden -of proving that he did not build or improve for the purpose of sale). . C3 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Profes'sions Code: The
Contractor's License Law does not aly to- an owne(of pr'opert 'wHo builds or improves thereon, and contracts for such, projects with contractor(s) licensed
-pursuant to the Contractor's License Law). - 55
0 I am exempt under Section Business and Professions Code for this reason:
I personally plan to provide the major labor and materials-for construction of the proposed property improvement. 0 YES ONO
I (have / have not) signed an application for a building permit for the proposed #ork.
I have contracted with the following person (firm) to provide-the proposed construction (include name I address'/ phone nuribe / contractors license 'number):
I-plan to provide portions of the work, but I have hired the following person to coordinate, sLipervfse and provide the major work(include name / address / phone
number / contractors license number): - S
- -' 5 -
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number, / type. of work)
PROPERTY OWNER SIGNATURE DATE
MPLET1S_SECTlOYi'?D
- Is the applicant or future building occupant required to submit a business plan, acutely hazardous' materials re streition form or risk management and 'prevention
program under Sections 25505, 25533 or.25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES-. 0 NO S
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the faciIityto be constructed within 1,000 feet of-the outer boundary-of a school site?• 0- YES' .0 NO
IF ANY OF THE ANSWERS'ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERViCES AND' THE AIR POLLUTION CONTROL DISTRICT. . S
- ,_' - * '"JT JS :. Kim
I hereby affirm that there is a construction lending agency for the performance of the work rot which this permit is issued (Sec 30970) Civil Code)
.LENDERrS NAME , ' ' - " ' 'LENDER'S ADDRESS
I9_1PANT"CERTI!cATION -
l'certify that'I have read-the' application and state that th'eabove infomation is correct and that the information on the plans is accurate. 'I 'agree to comply. with all City. ordinancesand State laws relating to building construction. l'hereby'authorize representatives of the Cit' of Carlsbad'to enter upon the abOve mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS !E-RMIT.
OSHA: An' OSHA permit is required for ècavations over 5'O' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION:. Every permit issued by the Building 0fficia1underthe provisions of this Code 'shah expire by limitation and become null and void if the building or
work authorized by such permit is not commenced within 365 days from the date of such Permit or if the building or, work authorized by such permit is suspended or abandoned-at any time after the work iscommenced for 'a period of 180 days '(S ti &4:4 Unirm Building Code),
APPLICANT'S SIGNATURE DATE
---__- _
- _
WHITE: File 'Y__LOWApplicant PINK: Finance
CITY OF CARLSBAD
INSPECTION REQUEST
PERNIT# CB973828 FOR 09/18/98
DESCRIPTION: CTI LOBBY REMODEL 1000 SF
TYPE: CTI
JOB ADDRESS: 2131 PALOMAR AIRPORT RD
APPLICANT: WHARTON LARRY
CONTRACTOR:
OWNER:
REMARKS: C/CHUCK/587-1901
SPECIAL INSTRUCT:
INSPECTOR AREA DH
PLANCK# CB973828
0CC GRP
CONSTR. TYPE NEW
STE: LOT:
PHONE: 619 203-1773
PHONE:
PHONE:
INSPECTOR 9W
TOTAL TIME:
--RELATED PERMITS-- PERNIT# TYPE STATUS
CB900399 ITI EXPIRED
AS980091 ASTI ISSUED
CD LVL DESCRIPTION ACT COMMENTS
19 ST Final Structural
29 PL Final Plumbing
***** *****
39 EL Final Electrical
49 ME Final Mechanical
INSPECTION HISTORY
DATE DESCRIPTION ACT INSP
081798 Rough Combo AP DH
081498 Exterior Lath/Drywall AP DH
081498 Interior Lath/Drywall AP DH
081298 Rough Combo AP DH
081198 Shear Panels/HD's AP DH
081098 Rough/Ducts/Dampers AP DH
081098 Rough Electric CO DH
081098 Frame/steel/Bolting/Welding CO DH
COMMENTS
APPROVED ON 8/11
INSTALL LIGHT FIXTURES
FIRE CAULKING
1
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING (FE PLANNING CMWD ST LITE
PLAN CHECK#: CB973828 DATE: 09/18/98
PERNIT#: CB973828 PERMIT TYPE: CTI
PROJECT NAME: CTI LOBBY REMODEL 1000 SF
ADDRESS: 2131 PALOMAR AIRPORT RD SEP 17 1998 }
CONTACT PERSON/PHONE#: C/CHUCK/587-1901
SEWER DIST: CA WATER DIST: CA By
INSPECTED DATE
BY: 0. c-L INSPECTED: APPROVED X DISAPPROVED -
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
COMMENTS:
EsGil Corporation
rofesioita[zn Review Engineers
DATE: 2/10/98
JURISDICTION: Carlsbad
PLAN CHECK NO.: 97-3828
U APPLICANT
JURIS
LAN REVIEWER
U FILE
SET: II
PROJECT ADDRESS: 2131 Palomar Airport Rd.
PROJECT NAME: Carlsbad Business Plaza Office Park TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
11111 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) . Fax #:
Mail Telephone Fax In Person .
REMARKS:
By: Mike Puckett Enclosures:
Esgil Corporation
D GA 11 CM [:1 EJ U PC 2/2/98 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax(619)560-1576
EsGil Corporation
fProfessiona[!P(ai Review Engineers
DATE: 12/30/97
JURISDICTION: Carlsbad
PLAN CHECK NO.: 97-3828 SET: I.
PROJECT ADDRESS: 2131 Palomar Airport Rd.
PROJECT NAME: Carlsbad Business Plaza Office Park TI
O APPLICANT
0 PLAN REVIEWER
O FILE
I11, The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
El The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department
staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the checklist is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the checklist has, been sent to:
Larry Wharton
639 Bison Ct. El Cajon, Ca. 92019
Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has
been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
S
Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: . S
By: Mike Puckett Enclosures:
Esgil Corporation
LI GA [1 CM [1 EJ [1 Pc 12/22/97 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax(619)560-1576
Carlsbad 97-3828
12/30/97
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 97-3828
OCCUPANCY: B
ITYPE OF CONSTRUCTION: III-lhr
ALLOWABLE FLOOR AREA:
SPRINKLERS?: Yes
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 12/17/97
DATE INITIAL PLAN REVIEW
COMPLETED: 12/30/97
JURISDICTION: Carlsbad
USE: Office
ACTUAL AREA: 32,855sqft
STORIES: 3
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 12/22/97
PLAN REVIEWER: Mike Puckett
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
Code sections cited are based on the 1994 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot
Carlsbad 97-3828
12/30/97
1. Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for commercial/industrial projects (two sets.of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City
of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009,
(619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-
1468. Deliver all remaining sets of plans and calculations/reports directly to the City
of Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Plans and calculations shall be signed by the California state licensed engineer or
architect where there are structural changes to existing buildings or structural
additions. Please include the California license number, seal, date of license
expiration and date plans are signed. Business and Professions Code.
3. Provide a statement on the Title Sheet of the. plans that this project shall comply
with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC.
4. Note that new entry doors/side panels will have tempered glazing.
5. Show on plans that new entry doors have the required 10" kickplate at bottom of
door for disabled access requirements.
6. Specify lever-type hardware for passage doors on floors accessible to the disabled.
Section 2-3304, Title 24.
7. Note on the plans: "All exits are to be openable from inside without the use of a key
or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies,
you may note "Provide a sign on or near the exit door, reading THIS DOOR TO
REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed
at the main exit. Section 1004.3.
8. Show that the double entry door hardware complies with Section 1004.3
9. If a room with an exhaust fan has a door opening into a rated corridor, show how
makeup air will be provided to the room. The door cannot be undercut, nor can a
louver in the door be provided. Section 1005.8.1. This applies to the restrooms off
the exit corridor.
Carlsbad 97-3828
12/30/97
Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor--
ceilings and roof-ceilings shall be protected as required in UBC Sections 709 and
710."
Detail the wall in the corridor/shaft where the new mail boxes are to be installed.
Show how the rated wall will maintain its fire rated construction.
ELECTRICAL
Indicate wiring method, i.e. EMT, metal flex. Make note on the plan that No AC
cable or Romex wiring methods are allowed.
Show exit signs on the electrical lighting plan(s). As per Sections 1012 and 1013 of
the 1994 UBC, provide two sources of power to exit signs and exit illumination.
MECHANICAL
Show on plans that the dampers installed with the new ducting are both smoke and
firerated. Show how smoke dampers will be actuated.
Smoke dampers in addition to Fire dampers shall be installed per Section 713.10 at
all ducted or unducted air openings at penetrations of:
. The fire-resistive construction of corridors, or horizontal exit walls.
Detail disposal of main condensate drainage from air conditioning units. (UMC
Section 310)
Detail overflow (secondary) condensate discharge from air conditioning units that
are in a ceiling space, to a readily observable location. (UMC Section 310.1.1.)
ENERGY
Provide a completed and signed LTG-1 form on the plans and provide the energy
design showing energy compliance.
Carlsbad 97-3828
12/30/97
DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL
TITLE 24 DISABLED ACCESS REQUIREMENTS
19. The following disabled access items are taken from the 1995 edition of California
Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded
public accommodations and commercial facilities shall be accessible to persons
with disabilities as follows:
Any building, structure, facility, complex, or improved area, or portions thereof,
which are used by the general public.
Any sanitary facilities which are made available for the public, clients, or employees
in such accommodations or facilities.
Any curb or sidewalk intended for public use that is constructed with private funds.
All existing accommodations when alterations, structural repairs or additions are
made to such accommodations.
NOTE: All Figures and Tables referenced in this checklist are printed in the
California Building Code, Title 24.
REMODELS, ADDITIONS AND REPAIRS
When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected is required to
comply with all of the requirements for new buildings, per Section 11 34B.2. These
requirements apply only to the area of specific alteration, repair or addition and
shall include:
22.A primary entrance to the building and the primary path of travel to the area in
question, and include the following items which serve the area in question:
Sanitary facilities.
. Drinking fountains.
Public telephones.
23. If an unreasonable hardship finding is granted, priority should be given to those
elements that will provide the greatest access, per Section 11 34B.2.1 Exception #1.
The order of priority shown below should be followed:
An accessible entrance.
An accessible route of travel.
At least one accessible restroom for each sex.
Accessible telephones.
Accessible drinking fountains.
24. When possible, additional accessible elements such as parking, storage and
alarms.
Carlsbad 97-3828
12/30/97
For areas under the control bf. ingle tênan, the obligation to provide access may
not be evaded by performing a series of small alterations to the area served bya
single path of travel, if those alterations could have been performed as a single
undertaking. If an area has been altered without providing an accessible path of
travel to that area, and subsequent alterations of that area, or a different area along
the same path of travel are undertaken within three (3) years of the original
alteration, the total cost of alterations to the areas along that path of travel during
the preceding three year period shall be considered in determining unreasonable
hardship.
Certain types of privately funded, multi-story buildings that were previously exempt
from providing access are no longer exempt from providing access, per Section•
113413.2.1 Exception #2. In alteration projects involving buildings previously
approved and built without elevators, areas above and below the ground floor
are subject to the unreasonable hardship provisions, even if the valuation of the
project exceeds the valuation threshold (ENR US20 Cities). These types of
buildings include: . .
Office buildings of three or more stories or ~!3000 ft2 in area, per floor.
Passenger vehicle service stations.
Offices of physicians, surgeons, and other health care providers such as dentists,
optometrists, etc.
Shopping centers.
Other buildings and facilities of ~!3 stories and ~!3000 ft' per floor, if a reasonable
portion of services are available on an accessible level.
Projects which consist only of heating, ventilation, air conditioning, reroofing,
electrical work (not involving placement of switches and receptacles), cosmetic work
that does not affect items regulated by Title 24 (i.e. painting, carpeting), etc. are not
considered alterations for the purpose of accessibility and are not subject to these
requirements, per Section 11 34B.2. 1 Exception #4.
27. Show that the existing restroom facilities comply with current disabled access
requirements. . .
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
4
Carlsbad 97-3828
12/30/97
Have changes been made to the plans not resulting from this correction list? Please
indicate:
YesU No LJ .
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468,
to perform the, plan review for your project. If you have any questions regarding
these plan review items, please contact Mike Puckett at Esgil Corporation.
Thank you. .
Carlsbad 97-3828
'12/30/97
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 97-3828.
PREPARED BY: Mike Puckett DATE: 12/30/97
BUILDING ADDRESS: 2131 Palomar Airport Rd.
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: III-lhr
BUILDING PORTION BUILDING AREA
(ft.2)
VALUATION
MULTIPLIER
VALUE
($)
Tenant Improvement 1000 26.00 26,000.00
Air Conditioning
Fire Sprinklers
TOTAL VALUE 26,000.00
1991 UBC Building Permit Fee Bldg. Permit Fee by ordinance: $ 258.50
1991 UBC Plan Check Fee LI Plan Check Fee by ordinance: $ 168.03
Type of Review: LI Complete Review LI Structural Only El Hourly
fl Repetitive Fee Applicable LI Other:
Esgil Plan Review Fee: $ 134.42
Comments:
Sheet I of I
macvaluedoc 5196
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB 77 & DATE
ADDRESS 2 i
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL
(<$10,000.00)
VILLAGE FAIRE
(OM:PL:E:TEOFFICE B
I
UILDING
OTHE
PLANNER DATE
ENGINEER DATE
C:\WP51\FILES\BLDG.FRM Rev 11/15/90
0 k '
PLANNING DEPARTMENT J BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check CB Address
Planner XJ. Phone (619) 438-1161, extension
________ APN:I'?-O'?O'?3
CD Type of Pject and .Use: /' _7M)Project Density:___________________
Zoning: _$1- 1 General Plan: Facilities Management Zone:
CFD inIy4)# Date of participation: Remaining-net dev acres:_____
.
CirreO
(For non-residential development: Type of land used created by
thispermit:_______________________________________________
Legend: 1,nJ Item Complete Q1 Item Incomplete - Needs your action
Environmental Review Required: YES NO TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require
a
c
t
i
o
n
.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
OTHER RELATED CASES:
YES __ NO __ TYPE_
DATE
Compliance with conditions or approval? If not, state conditions which requir
e
a
c
t
i
o
n
.
Conditions of Approval:______________________________________________
_
_
_
_
_
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone?. YES____ NO____
CA Coastal Commission Authority? YES___ NO
If California Coastal Commission Authority: Contact them at
- 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES
NO____ If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at m
i
n
i
m
u
m
Floor Plans).
Complete Coastal Permit Determination Log as needed.
Inclusionary Housing Fee required: YES
____ NO (Effective date of Inclusionary Housing Ordinance- May 21, 1993.)
Data Entry Completed? YES NO
(Enter CB #; UACT; NE)CT12; Construct housing V/N; Enter Fee Amount (See fee schedule for amou
n
t
)
:
R
e
t
u
r
n
)
Site Plan:
Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
Street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
Provide legal deicription of property and assessor's parcel number..
Zoning:
O 0 1. Setbacks:
. Front: '. Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown
0 0 0 2. Accessory structure setbacks:
Front: Required Shown Interior Side: Required S Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown
0 0 3.. Lot Coverage: Required Shown
4. Height.:• . Required Shown
0 0 5. Parking: Spaces Required Shown
Guest Spaces Required
.. Shown
0 El El Additional Comments N '((k1 £2-QQeSI A NONLA -
W 4,t P. ycwo Tiu .7. r-7'
VeHwo-v_( ,
ZMr - 2I e .ç'( Q44V4+4- k CrjJ - OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE
.V7 DAT
City of Carlsbad 97461
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check
Date of Report:Friday, February 6, 1998 Reviewed by:
Contact Name Larry Wharton
Address 639 Bison Ct
City, State El Cajon CA 92019
Planning No.
Job Name C. Bus. Plaza Bldg 4
Job Address 2131 Palomar Airport Ste. or Bldg. No.
CK Approved - The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in this report can result in suspension of permit to
construct or install improvements.
E Disapproved - Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Department Use Only
Review 1st 2nd 3rd
Other Agency ID
cFD Job# 97461 File# --