Loading...
HomeMy WebLinkAbout2148 AVENIDA TORONJA; ; CB981845; PermitPermit No: CB981845 I 06/19/93 13:20 Project No: A9802447 Page 1 of 1 Development No: CEV89110 Job Address: 2148 AVENIDA TORONJA Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 255-261-12-00 Lot#: 165 Valuation : 207,451 Consmem:wN 02 Occupancy Group: Reference#: CT88-03 staem ~ssu~m.s.lt~ Description: PLAN 3,PHS 4,2317+699 GAR+86 Applied: 05/04/98 : DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF Apr/Issue: 06/22/98 Entered By: RMA Appl/Ownr : KAUFMAN & BROAD 619 259-6000 12626 HIGH BLUFF DR # 400 SAN DIEGO CA 92130 Plan Check Numbers > ORIG 972911 PCK 981304 A** Fees Required *A* *I* Fees Collected & Credits *** Fees : 11,215. Adjustments: Total Fees: 11,215. See description Number of Bedrooms Number of Bathroom Building Permit Plan Check Strong Motion Fee Enter Plan Check E Enter "Y" to Autoc Enter "Y" to Autoc Payoff Fee for CFD Enter LFM Fee (Zon Enter "Y" for Plumbi Each Plumbing Fixture Each Building Sewer Each Install/Repair Wa ~ Each Water Heater and/or ' Gas Piping System Each Vacuum Breaker Enter "Y" for Electric Issue Fee > ,00 .oo 11,215.83 Ext fee .---____--__ 4.00 2.75 999.00 649. 00 21. no -52.00 3776.00 550.00 4698.83 310.00 20.00 98.00 15.00 7.00 7.00 7.00 14.00 10.00 ----- Data ----- x Y Y Y Single Phase Per AMP > 125 .25 31.25 Enter 'Y' for Mechanical Issue Fee> 15.00 Y Install Furn/Ducts/Heat Pumps > 2 9.00 18.00 Each Install Fireplace > 1 6.50 6.50 Each Exhaust Fan > 1 6.50 6.50 Each Install/Reloc Vent > 2 4.50 9.00 1- ---- I CLEARANCE __.._ ..---- I- ,, I %LA, ._ ..=, CITY OF CARLSBAD 2075 Las palmas Dr., Carlsbad, CA 92009 (619) 438-1161 FINAL BUILDING INSPECTION - DEFT: BUILDING ENGImERING FIRE PLANNING CMWD ST LITE PLAN CHECK#: CB981845 PERMIT#: CB981845 PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 ADDRESS: 2148 AVENIDA TORONJA DECK+48 SF PORCH,VILLAGE Q,LA CONTACT PERSON/PHONE# : C/HAROLD/436-6517 SEWER DIST: LC WATER DIST: 0 DATE: 10/08/98 PERMIT TYPE: SFD COSTA, KAUF Lot# 165 .?$ ’ - DATE /PA2 INSPECTED: /Oj/$*?g APPROVED 1/ DISAPPROVED - INSPECTED BY: INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION - DEPT: BUILDING ENGINEERING FIRE PLANEJING CMWD ST LITE PLAN CHECK#: CB981845 DATE: 10/08/98 PERMIT#: CB981845 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VIUAGE Q,LA COSTA,KAUF ADDRESS: 2148 AVENIDA TORONJA Lot# 165 CONTACT PERSON/PHONE# : C/HAROLD/436-6517 SEWER DIST: LC WATER DIST: 0 INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION - DEFT: BUILDING ENGINEERING FIRE PLANNING CMWD ST LITE PLAN CHECK#: CB981845 DATE: 10/08/98 PERMIT#: CB981845 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF ADDRESS: 2148 AVENIDA TORONJA Lot# 165 CONTACT PERSON/PHONE# : C/HAROLD/436-6517 SEWER DIST: LC WATER DIST: 0 INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION - DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD . ST LITE PLAN CHECK#: CB981845 DATE: 10/08/98 PERMIT#: CB981845 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 4,2317+699 GAR+86 DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF ADDRESS: 2148 AVENIDA TORONJA Lot# 165 CONTACT PERSON/PHONE# : C/HAROLD/436-6517 SEWER DIST: LC WATER DIST: 0 DATE A&-- INSPECTED: / 0 114 APPROVED -- DISAPPROVED - INSPECTED BY : INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB981845 FOR 10/16/98 INSPECTOR AREA NF DESCRIPTION: PLAN 3,PHS 4,2317+699 GAR+86 PLANCK# ORIG 972 TYPE: SFD CONSTR. TYPE VN APPLICANT: KAUFMAN & BROAD PHONE: 619 259-6000 OCC GRP DECK+48 SF PORCH,VILLAGE Q,LA COSTA,KAUF JOB ADDRESS: 2148 AVENIDA TORONJA STE : LOT: 165 CONTRACTOR: PHONE : OWNER: PHONE: REMARKS: R/436-6517 INSPECTOR SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 29 39 49 ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical m ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 100798 100698 090998 090398 083198 082798 082598 082498 081298 081098 080798 080798 070998 070898 070898 070798 062598 062598 Final Electrical Final Electrical Drywall/Ext Lath/Gas Test Drywall/Ext Lath/Gas Test Drywall/Ext Lath/Gas Test Insulation Rough Combo Rough Combo Roof Sheathing/Ext Shear Roof Sheathing/Ext Shear Roof/Reroof Shear Panels/HD's Underground Combo Steel/Bond Beam Ftg/Foundation/Piers Underground Combo Underground/Under Floor Sewer/Water Service CA NF APPD ON 10/6 AP NF CA NF APPD ON 913 AP NF NR NF AP NF AP NV NR NF AP NF NR NF NR NF NR NF CA NF AP NF AP NF NR NF AP NF AP NF SOUTHERN CALIFO’RNIA SOIL AND TESTING, INC. 6280 RIVERDALE STREET, P. 0. Box 600627, SAN DIEGO, CA 92 160 (61 9) 280-432 1 71 98 Concrete Compressive Strength Test Report 71 99 File Number: 9812071 Project Title: Westfield Village “Q” Project Location: 21 48 Avenida Toronja Architect: Kaufman & Broad Engineer: J. L. Davidson Contractor: Kaufman & BroadKoncrete Concepts 71 98 Permit No: 981 -845 Plan File No: 71 99 Location In Structure: Material Supplier: Superior Ready Mix Mix Designation: 35P Admixture(s): Time In Mixer (Minutes): Slump, Inches: 5 CC Temp: 0 Truck Number: 53 1 Ticket Number: 234141 Air Temp: Samples Fabricated By: JB Samples Tested By: NH Air Content: Lot 165 - North West Quad Post-Tension Slab-on-Grade 0 K 08-06-98 79,500 2,810 Laboratory Number: Mark: 165 Date Made: Date Received Date Tested Diameter, Inches Area, Square Inches Maximum Load, Pounds Compressive Strength, psi Age Tested, Days Required 28 Day Strength, psi 08-06-98 81,250 2,870 71 97 08-06-98 79,500 2,810 07-09-98 07-1 0-98 07-20-98 6.00 28.27 50,750 1,800 11 2,500 08-06-98 81,250 2,870 Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM standards. This agency makes no other warranties express or implied. Distribution: (2) Kaufman & Broad (1) City of Carlsbad (1) Superior Ready Mix Reviewed By: I George Gavit, RCE #56564 07-09C 8/6/98