Loading...
HomeMy WebLinkAbout2153 ALGA RD; ; CB950198; Permitci :I ' r .,/Oj/i)5 1II: 54 BUILDING PERMIT Permit Nil: CB950198 Project No: AY5C10262 I Paqe 1 of 1 Deve.lopmcnt. No : Job Address: 2153 ALGA KD Permit Type: RESIDENTAL ADD/ALT Parcel No: ~15-22O-E;6-llO Lot# : Va!uation: Construct icn Type : VN Occupancy Grr>up: C-FfMT m.oo Description : INTERLilR REMODEL AND ENLARGE Ayplic-d: :12i06i'35 Apr/Issue: (1 li(19/9i Suite : t55,(100 0995 03/09/95 0001 01 02 Ref esence# : Stat,us: ISSUETI : ENTRY Entereci By: KDP Appl./Ownr : CAYWOOD, TOM 619 579-9335 436 S. MAGNOLI EL CAJON, CA. "ic I """"""""_"_" A(.ljuscrnents: Fees : Tot.?il Fees : Fee description """"""""" Plan Check Building Permit Strong Mot.ion Fee * BlIlLDING 'TOTAL Crecii t.2 k* * 581 . 00 Ext fee Data CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PLICAlTON City of Carlsbsd Building Depnrt.ent 2075 Las Palms Dr., Carlsbed, CA 92009 (6191 436-1161 E From list 1 (see back) give code of Permit-Type: .................................................... For Residential Proiects Only: From List 2 (see back) give Code of Structure-Type: I PLAN CHECKNO. \?.a I " Net WGain of Dwelling Units I 2 PRCMXXINFoRMAnoN FOR OFFICE USE ONLY STATE LIC. x 46% QI LICENSE cws Is CITY BUSINESS LIC. x (last name tmt) q woov , f'0p.r 36 <, LND e. 0 Ld\Iou STATE >*. ZIPCODE ~~~~ an ON Workers' mmpensatlon Declaration: 1 hereby attlrm that I have a certlhcate ot consent to selt-Insure Issued by the Dlrector ot lndustnal Relations, or a certificate of Warken' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Depamnent (Section 3800, lab. C). INSURANCE COMPANY Cemtlcate Ot Exemptmn: 1 certl that fin the pertormance ot the work tar whlch thls permlt IS lssued, 1 Shall not employ any penon In any manner so as to kame subject to the W?rken' Compensation Laws of California. POIJCY NO. EXPlRATlON DATE SIGNATURE DATE 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the strucNre is not intended or Uwner-Budder ~e~larat~on: I hereby attlrm that 1 am exempt trom the contractors ucense Law for the Lollowlng reason: offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license law does not apply to an owner of property who builds or improves thereon, and who dog such work himself or through his own employeer, provided that such improvements are not intended of proving that he did not build or improve for the purpose of sale.). or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law dog not apply to an owner of property who builds or improves thereon, and contracts for such projects with conuactor(s) licensed pursuant to the Contractor's License law). 0 I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any strucNre, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's license law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollan [SSOO]). SIGNA'NRE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Is the applicant or future building occupant required to obtain a permit from the air pollution conml district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? aANYOFTHEAN~AREYE$AFINAL~~~TEOFOOCUPANOIkUYNOTBEISSUED-JULY1.1989UNIffSTHEAPPUCANT HAS MIX OR 1s MEFIING THE REQ- OF THE OFFICI! OF EMwGwcI SERVICES AND THE AIR FQLLUTlON CONTROL DISI'IIIa. I hereby athrm that there IS a construction lending agency tor the pertormance Ot the Work tor WhlCh th!S pel" IS Issued (SX 3097(~) ClVll Code). 0 YES 0 NO 0 YES 0 NO 0 YES 0 NO LENDER'S NAME LENDER'S ADDRESS I cert! that 1 have read the appllcatlon and state that the akve mtormatlon IS correct. 1 agree to comply wlth all wty ordlnances and State laws relatin! to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. IAISOAGREETOSAVEINDEMNIFYAND~HARMIESSTHE(TIYOFcARlsBADAGAINSTAU.~~JUDG~ODSIS AND EXPENSFS WHICH MAY IN ANY WAY ACCRUE AGAINST sA[D CITY IN CONSEQ~CE OF 'IHE GRAIFlING OF lHE Pm. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of StrUcNres over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commend within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or for a period of 180 days (Section 303(d) Uniform Buil 'ng Code) APPLICANTS SIGNATURE DATE: 4t-C, ~- 4 5- WHITE. File YELLOW Applicant PINK: Finance i3 - CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB950198 FOR 04/25/96 INSPECTOR AREA PD DESCRIPTION: INTERIOR REMODEL AND ENLARGE TYPE: RAD CONSTR. TYPE VN APPLICANT: CAYWOOD, TOM JOB ADDRESS: 2153 ALGA RD CONTRACTOR: PHONE : OWNER: PHONE : REMARKS: MW/DEBBIE/579-1365 INSPE SPECIAL INSTRUCT: ENTRY OCC GRP PLANCKY CB950198 'PHONE: 619 579-9335, STE : LOT: . TOTAL TIME: "RELATED PERMITS-- PERMIT# TypE RW950037 ROW STATUS ISSUED ~~~ ~ ~ ~ ~ CB950297 RAD ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical " f - " - ***** INSPECTION HISTORY ***** DATE 022796 091895 091895 083195 083195 083195 083195 080995 080995 061495 051895 061495 051695 050195 042495 041295 040595 040395 040395 031695 031395 DESCRIPTION compliance Investigation Interior Lath/Drywall Exterior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Rough/Topout Shear Panels/HD*s Roof/Reroof Gas/Test/Repairs Grout Rough Electric Ftg/Foundation/Piers Exterior Lath/Drywall Interior Lath/Drywall Rough Combo Insulation Ftg/Foundation/Piers Rough Combo Underground/Under Ploor Frame/Stael/Bolting/Welding ACT INSP COMMENTS AP PD AP PD AP PD NR PK NR PK NR PK AP PK AP PD CO PD AP PD AP PD AP PD AP PD PA PD PA PD PA PD PA PD CO PD CO PD PA PD CO PD ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: 3 f 8 195 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-198 PROJECT ADDRESS: 2153 Alga Road PROJECT NAME: SFD Addition 8s Remodel SET I11 0 FILE Ix] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: Ix] Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: 0 REMARKS: By: David Yao Enclosures: Esgil Corporation 0 GA 0 CM 0 PC log trnsmtl.dot ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: 3/3/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-198 PROJECT ADDRESS: 2153 Alga Road PROJECT NAME: SFD Addition & Remodel SET I1 0 APPLICANT 0 PLAN REVIEWER 0 FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant‘s copy of the check list has been sent to: (0.5 FAYLD TD g s?Cr -453%) Tom Caywood 436 S. Magnolia Avenue Suite 106 El Cajon CA 92020 Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed, Person contacted: Date contacted: (by: 1 Telephone #: 0 REMARKS: By: David Yao Enclosures: Esgil Corporation 0 GA CM 0 PC 2/24 tmsmtl.dot - RECHECK PLAN CORRECTION LIST ROJECT ADDRESS: 2153 Alga Road SET: I1 DATE PLAN RECEIVED BY ESGIL CORPORATION: 2/24 DATE RECHECK COMPLETED: 3/3/95 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo Carlsbad 95-198 3/3/95 1. 15. 24. 34. 35. Please make all corrections on the original tracings and submit two new sets of prints to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. A) Provide more detail calculations or comments to show how the lateral froce along line 2 -2 is resisted by the structural beams. What is the lateral force along line 3 - 3 ? Provide calculations to show the shear wall and hold down anchors are adequate. B).There is minimum edge distance requirement for the epoxy anchor(lCB0 # 4945). Check the report and note or show the edge distance on the plan. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: 0 Yes 0 No 36. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: 2/15/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-198 PROJECT ADDRESS: 2153 Alga Road PROJECT NAME: SFD Addition & RemodeI SET I 0 APPLICANT 0 PLAN REVIEWER ~JURISDICTI~ a FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Tom Caywood 436 S. Magnolia Avenue Suite 106 El Cajon CA 92020 Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: 0 REMARKS: By: David Yao Enclosures: Esgil Corporation 0 GA 0 CM 0 PC 217 lmsmtl.do1 Carlsbad 95-198 21 15/95 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PROJECT ADDRESS: 2153 Alga Road FLOOR AREA: addition 147 sq.ft. STORIES: 2 HEIGHT: -22 ft. ATE PLANS RECEIVED BY DATE PLANS RECEIVED BY URISDICTION: 2/6 ESGIL CORPORATION: 2/7 DATE INITIAL PLAN REVIEW PLAN REVIEWER: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1991 UBC (effective 8/14/92), 1991 UPC (effective 8/14/92), 1991 UMC (effective 8/14/92) and 1990 NEC (effective 7/1/91). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process. olease note on this list for a copy! where each correction item has been addressed. i.e.. plan sheet number. specification section. etc. Be sure to enclose the marked up list when vou submit the revised plans. LIST NO. 1. GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1991 UBC) r3fom.dot 1. 2. 3. 4. 5. 6. Carlsbad 95-198 2/15/95 Please make all corrections on the original tracings and submit two new sets of prints to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. The portion of the plan designed by Mr. Curtis shall be signed and sealed by him. Indicate on the Title Sheet of the plans the name of the legal owner. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and the 1991 UBC, UMC and UPC and 1990 NEC. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony. Section 302(d). On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 302(c). REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQUIRED? REMARKS * FIELD WELDING * HIGH STRENGTH BOLTS * EXPANSlONlEPOXY ANCHORS * DESIGNER-SPECIFIED 9 OTHER GENERAL RESIDENTIAL REQUIREMENIS 7. Show safety glazing in the following locations, per Section 5406(d): a) Where the nearest edge of glazing is within a 24-inch arc of either side of a door in a closed position (unless there is an intervening wall between the door and the glazing or if the glazing is 3-0" or higher above the walking surface).(window F next to door 2) above the floor and the top edge greater than 36" above the floor (unless the glazing is more than 36 horizontally away from walking surfaces or if a complying protective bar is installed).(all french doors) b) Glazing greater than 9 square feet with the bottom edge less than 18 Carlsbad 95-198 2/15/95 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. EXITS, STAIRWAYS, AND RAILINGS Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. FOUNDATION REQUIREMENTS Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (0. FRAMING Note on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof". Section 1708. Provide framing sections through dressing room Section 302 (d). Is the wall for dressing room new? or existing ? Is dressing room new conditioned floor area? Page 4 of the calculations shows the 8 x 10 beam connect to existing 4 x 10 beam by 3/4 " bolts @ 16 "O.C. staggered. The detail 3418 or the framing plan did not show it. Provide calculaitons to justify that the deflection for the TS 6x6x1/4 columns at front entry comply with UBC 2334(h) drift limitation.(.oo5 x h) Provide calculaitons to show that the grade beam undeneath the TS 6x6 columns at front entry does not need any shear reinforcement. Provide complete lateral force analysis for the project since a lot of interior walls have been removed. The shear force for the premeter wall may be changed. The analysis shall show the force in east-west direction too. The schematic plan shown in the calculaiton does not match the floor framing plan. Please check. Provide calcualtion to show that the stress for the columns under combined axial and bending loading are under the allowable stress. Provide calculations to show that the deflection for all columns comply with UBC 2334(h) drift limitation.(.005h) Provide calculations to justify all new steel beams and columns on the floor framing plan are adequate. Carlsbad 95-198 2/15/95 20. 21. 22. 23. 24. 25. 26. 27. Provide calculations to show that all the girder-to-column connectionsof the moment frames comply with UBC 2710(9. Provide a detailed schematic plan of the building to show which tributary area is applied to the new frames which you have designed to resist vertical and lateral loads. I can not determine from the calculations what area you are using to load the frame. MECHANICAL (UNIFORM MECHANICAL CODE) Note on the plans that the FAU closet or alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 704. Note on plan: Gas vents and noncombustible piping in walls, passing through three floors or less, shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (c). ELECTRICAL (NATIONAL ELECTRICAL CODE) All wiring shall comply with the National Electrical Code. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. Note on the plans that receptacle outlet locations will comply with 1990 NEC Art. 210-52(a). Show on the plans that countertop receptacle outlets comply with 1990 NEC Art. 210-52(c), which reads as follows: In kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches. Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space. Island and peninsular countertops 12 inches or wider shall have at least one receptacle for each four feet of counter top. Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces. Receptacles rendered inaccessible by appliances fastened in place or appliances occupying dedicated space shall not be considered as these required outlets. Show on the plan that ground-fault circuit-interrupter protection complies with 1990 NEC Art. 21 0-8, which reads as follows: All 125-volt, single-phase, 15- and 20- ampere receptacles installed in bathroom 2 , garages, outdoors. Carlsbad 95-198 2/15/95 28. 29. 30. 31. 32. 33. 34. 35. PLUMBING (UNIFORM PLUMBING CODE) New water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard AI 12.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard A1 12.19.2. H & S Code, Section 17921.3(b). ENERGY CONSERVATION NOTE: Plans submitted after January 1, 1993 must comply with the new energy standards. Provide plans, calculations and worksheets to show compliance with current energy standards. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. For room additions, show compliance with the energy standards. See attached. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen@) and bathrooms. Provide a note on the plans stating "All new glazing (fenestrations) will be installed with a certifying label attached, showing the U-value." MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: P Yes 0 No Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. 36. The jurisdiction has contracted with Esgil Corporation located at 9320 Carlsbad 95-198 a/ 15/95 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 95-198 PREPARED BY: David Yao DATE: 2/15/95 BUILDING ADDRESS: 2153 Alga Road BUILDING OCCUPANCY: R-3/M-1 TYPE OF CONSTRUCTION: V-N I I I I I I I I I I I Building Permit Fee: Plan Check Fee: $ 572.00 $ 371.8 Comments: Sheet 1 of 1 valuefee.dot BUILDING PIANCHECK CHECKLIST DATE: PLANCHECK NO. CB ./d5 /qf PROJECT DESCRIPTION: /&5, koD FA?%+# df/ ,-.?/x3 ALdA ED ASSESSORS PARCEL NUMBER: .%/X* LVO - 5- ' EST. VALUE ~37- ENGINEERING DEPARTMENT APPROVAL me nem you have submitted for review has been approved. me approval Is based on plans, Information and/or specmcations provided in your submittal; therefore any changes to these nems after this date, including field modiications, mwt be reviewed by this office to insure continued conformance wnh applicable codes. Please review carefully si1 comments attached, as failure to comply with Instructions In this report can result in suspension d permn to build. 0 A ~ight-of-~ay pemn is required priorto construction d the following improvements: DENIAL Please see the attached repon of deflclemiea marked with Make necessaly corrections to plans or standards. Submit wrrected plans andb specifcations lo this office for review. specWiOM foC COmplianCe with applicable cod= and By: Dale: By: Date: By: Date: AlTACHMENTS ENGINEERING DEPT. CONTACT PERSON 0 DedicatiM Appllcauon Dedication checltl$t improvement ~ppl~catlon 0 improvement Checklist 0 Future improvement Agreement Grading Permn Application 0 Grading Submittal Checklist Right d Way Permit Application Right of Way Permit Submittal Checklist and Infcfination Sheet NAME: Cny of carlsbad ADDRESS: 2075 Las Palmas Dr.. Carisbad. CA 92009 PHONE :J619) 4381161. €kt 0 Sewer Fee information Sheet A4 P\DOC8\CHKLBnBWOOI.CRU REVOW1194 2075 Las Palmas Dr. Carlsbad, CA 92009-1 576 - (619) 438-1161 FAX (619) 438-0894 1 sthndJ 3rdJ BUILDING PLANCHECK CHECKLIST SITE PLAN 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Unes Easements 8. Existing 8 Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-way Width i3 Adjacent Streets Show on site plan: A. Drainage Patterns C. Existing Topography B. Existing i3 Proposed Slopes Include note: 'Surface water to be directed away from the building foundation at a 2% gradient for no less than 5 or 2/3 the distance to the property line (whichever is less)." [Per 1985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). Include on title sheet A. Site address 8. Assessor's Parcel Number C. Legal Description For commerciaVindustrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Page 1 of4 REV OW1 lD4 BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 2ndd 3rdd 0 0 5. Project does not comply with the following Engineering Conditions of approval for Project No. 1 Conditions were complied with by: Date: DEDICATION REQUIREMENTS 0 0 6. Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 18.40.030. Dedication required as follows: 00 0 Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date: IMPROVEMENT REQUIREMENTS 7a. All needed public improvements upon and adjacent to the bullding site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans slgned by: Date: BUILDING PIANCHECK CHECKLIST on 1stJ 2ndJ 3rdJ on 0 LU on0 on 0 7b. Construction of the public improvements may be deferred pursuant to code Section property and processing fee of $ 18.40. Please submit a recent property title report or current grant deed on the so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows: Improvement Plans signed by: Date: 7c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: Date: 7d. No Public Improvements required. SPECIAL NOTE: Damaaed or defective imorovements found adiacent to buildina site must be reoaired to the satisfaction of the Cihr InsDector Drior to muDancv. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 8a. Inadequate information available on Site Plan to make a determination on grading requirements. Indude accurate grading quantities (cut, fill import, export). 8b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Gradina Permit must be issued and rouah aradina apDroval obtained orior to issuance of a Buildina Permit. Grading Inspector sign off by: Date: 8c. No Grading Permit required. Paga3d4 REVowII/S4 BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS 0 0 9. A RIGHT-OF-WAY PERMIT is required to do work in City Rightof-Way and/or private work adjacent to the public Rightof-Way. Types of work include, but are not limited to: street improvements, trees, driveways, tieing into public storm drain, sewer and water utilities. Rightof-Way permit required for A separate Right-of-way permit issued by the Engineering Department is required for the following: 0 0 10. A SEWER PERMIT Is required concurrent with the building permit issuance. The fee * is noted in the fees section on the following page. 0 0 11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: Date: Paga4al4 - WORKSHEET provided by Building Department.) //b> Item Incomplete - Needs your action W I, 2,3 Number in circle indicates plancheck number where dcfidency was idenrified "~cqukcd: YES-NO~TYPE DATE OF COMPLETION: Compliurce with conditionr of appnml7 If aot, state conditions which require action. Conditions of Approval YES-NOXTYPE APPROVAUR€SO. NO. DATE: PRWm NO. OTHER RUATED CASES: Compliance with condidom of approval? tf not, state conditions which require action. conditions d rrppronl - "C PamitRuphdYES-NO& DATE OF APPWVU San Mego Gout Disuict, 3111 CnmiM Del Rio Nod, Suite 200, Sm Diego, CA 92108-1725 (619) 521-8036 Compli.ncc wirh cod- of approval? If nor, state conditions which require action. Conditionr of Appronl ~ . 1. 2. zoning: 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: Norrh MOW, propvcy lines, 'easements, existing and proposed spuctures, smco, existing street hprovemcnp, rightof-way wid& dimensioned setbacks and existing r~pofnpbiul lines. Provide legal ddpdon of prom, and uswor's ParCCl number. Additiod Comments I. - iii?JkL APPROVAL DATE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 DATE: 4/5/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-198 rev. PROJECT ADDRESS: 2153 Alga Road PROJECT NAME: SFD Addition (k Remodel Revision 0 APPLICANT 6 JURI& 0 PLAN REVIEWER 0 FILE SET I1 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. H The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff, 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. c] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: REMARKS: Provide special inspection for the Simpson ET22 anchors. The owner II set is identical to the city I set. (city has the set) By: David Yao Enclosures: city approved set Esgil Corporation 0 GA 0 CM 0 PC log trnsmtl.dot . ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: 3/27/95 JURISDICTION: Carlsbad PLAN CHECK NO.: 95-198 rev. 0 APPLICANT tl" 0 PLAN REVIEWER 0 FILE SET I PROJECT ADDRESS: 2153 Alga Road PROJECT NAME: SFD Addition 8~ Remodel Revision 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Tom Caywood 436 South Magnolia Avenue #I06 El Cajon CA 92020 Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: 1 Telephone #: c] REMARKS: By: David Yao Esgil Corporation 0 GA 0 CM 0 PC 311 6 Enclosures: trnsmtl.dot Carlsbad 95-198 rev. 3/27/95 GENERAL PLAN CORRECTION LIST - JURISDICTION: Carlsbad PIAN CHECK NO.: 95-198 rev. PROJECT ADDRESS: 2153 Alga Road DATE PIAN RECEIVED BY ESGIL CORPORATION: 3/16 DATE REVIEW COMPLETED: 3/27/95 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. 1. 2. 3. 4. 5. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? 0 Yes 0 No Per ICBO M945, the allowable tensile load for 5/8" bolt is 4375 Ib. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. Cartsbad 95-198 rev. . 3/27/95 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PIAN CHECK NO.: 95-198 rev. PREPARED BY: David Yao DATE: 3/27/95 BUILDING ADDRESS: 2153 Alga Road BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: Air Conditioning Fire Sprinklers TOTAL VALUE Building Permit Fee: $ Plan Check Fee: $ Comments: Esgil fee= 1 x 87.15 = 87.15 City fee= 87.151.8 = 108.94 Sheet 1 of 1 valuefee.dot I I KEN~ETWBAKER . 381 0 kALAV0 DR. ClvIc ENGINEER RdE 14976 SPRINd VALLEY CA. 91 977 “- --rr MAR-28-95 TUE 14:46 SIMPSON R & D " Testing Engineers, Inc. May 10, 1994 FAX NO, 5108473068 P, 01 Qualify Assurance Services Mauriok Consulting Work F&quest Number W10.084 SIMPSON STRONGTIE COMPANY, LNC. Ple~ton, CA 94K88 4837 Chabot Drive, Suite 200 A"!?: Mr. Gmgg Summen Engineer, Lfauager of Testing SUBJ: SWSON STRONG-TIE EPOXY SYSTEM EX22 WITH 5/8" DIA. X E' EWED"l' DearMr.Summera: In accordance with your request, on May 8, 1994 we witnessed the tea& ddbed blow. El22 epoxy gyrtem with 518" x 12' embedment ASl" A307 all-thread rod The 518" diameter all thread rod was installed in a 8" x 18" x 38' concrete stem Wan with rebar hated 4' &om the bottom of the stem wall to reduce the bending in the concrete beam. The rebar waa placed greater than embedment depth, The all-thread rods were installed 1-3/4" from the edge and 6' fmm the end of the concrete specimen. The compressive strength of the concrete at the time of test was 2w) pi. The compression test report is attached. PROCEDURE Holes were drilled 314' x 15 with a rotor hammer. The holes were cleaned with compressed sir brushed with a nylon brush and cleaned agaib The ET22 epoxy was installed in the hole until it was approximately was dowed to set for two days. half'way !WL The all-thread rod m inserted into the hole and twisted to eliminate air pockets. The eporg aEsuLTs The resuits are tabulated on the enclosed Table A Lf you have any questions regar- this report, or if we may be of further service to you, pleare contact the undersigned. 281 1 Adsline Weer P.O. Box 24075 Oakland California 94823 (510) 835.3142 %MA CLARA * DMLO VAUW * %RPIMEMO * MONTERW MAR->8-95-.TUE 14: 47 SIMPSON R & D FAX NO, 5108473068 P. 02 -. COnCZeCe Spallad. Concreto Spa1l.d. Lowest UtLmata: 31700#/2/4 - Average Ultimate: 32300# /2= 16150R /4: 440' I- I".. PC 15