Loading...
HomeMy WebLinkAbout2153 Alga Rd; ; CBR2017-1874; PermitPrint Date: 09/27/2018 Job Address: 2153 Alga Rd PermitType: BLDG-Residential Parcel No: 2152205600 Valuation: $ 53,699.85 Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Residential Permit Work Class: Addition Lot#: Reference #: Construction Type Bathrooms: Orig. Plan Check#: _Plan Check #: (city of Carlsbad Permit No: CBR2017-1874 Status: Applied: Issued: Permit Finaled: Closed -Expired 08/15/2017 12/07/2017 Inspector: AKrog Final Inspection: Description: KAUFMAN: 252 SF ADDITION AT 2ND FLOOR FOR MASTER BATH // 207 SF REMODEL ON 1ST FLOOR TO CONVERT MASTER BATH TO OFFICE Applicant: Owner: DZN PARTNERS BART SMITH 682 2Nd St TRUST KAUFMAN KEN S TRUST 09-22-15 2153 Alga Rd Encinitas, CA 92024-3560 760-753-2464 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) CARLSBAD,CA 92009 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1 -Medium BLDG SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM Total Fees: $1,358.30 Total Payments To Date : $ 1,358.30 Balance Due: AMOUNT $423.72 $296.60 $43.00 $166.00 $52.00 $80.00 $3.00 $6.98 $232.00 $55.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees /exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of l;m;tahon has P'•EXPrrttff PE RM IT PERMIT HAs EXPIRED SECTION 106.4.4 AS A~~:::~tMCE WITH C.8.C. ~ · .C.18.04.030 DATE~.;i7-1s s,GNATURE ?tR HlK£ t. Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsba dca.gov THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: •PLANNING D ENGINEERING •BUILDING Q FIRE Q HEALTH D HAZMAT/APCD , Plan Check No~2!J\ "7 -\'O 7\..\ C_ City of Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 53,700- Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov www.carlsbadca.gov Date~-l'S-t7 lswPPP JOB ADDRESS 2.15 3 Al t3~ ROCALl SUITEt/SPACE#/UNIT# IAP2-15 -'2.20 -5/o -00 CT/PROJECT # ILOU I PHASE # 1 • OF UNITS I# BEDROOMS # BATHROOMS I TENANT BUSINESS NAME I cv=• i I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) -f' -~ • , d Add,(h t,-dd, +,', vi -lo, a.V)d r ew,odet in9 o I an e>c r · n9 2-story "' 3 te. fa.rvu I'/ ves I eY\c e : < of ~ 8:YOVl& .floor ~ 6ttt1A V)ex-\ +o ·t-vie.-exf~'n mtt~it'V-~ 1 vt ~€.:' lcCtt:hOYl Cl + O..Vl ex \'<:.n (It \o(J,..\(oV\.y, -~ 1o~:t11,V\?Ot'YI WI I\ p v1cte.... cxce,ess 1'() tv1-e eXIS.ti dee{,(,., tYlQ... -e)<f~tiV'-9 m.as r ba1'1A \,\>I'll le,€, ve,w\odele:i 1v1t-o o. vioVV\-Q., O.f'..ft•ce/de_n, lN1 mCAS~ k,a.(i,\ add-itiovi~ z.sz_ sr-~) Mo..s+er -oa-tt-\ r'VMOdeled -to off\·c.~ = 2. 0 1 s-t::. EXISTING USE FIREPLACE I PROPOSED USE I GARAGE (SF} PATIOS (SF} I DECKS (SF} YESl:K)# I AIR CONDITIONING I FIRE SPRINKLERS No0 YESl&]No• YES•No(X] APPLICANT NAME Ba.r+ GW1~ Dz..N ~r-\-ner-s PROPERTY OWNER NAME ken Kou+ man Pr"'••• Contact l ADDRESS lo<Z 2-second Str-ee+ ADDRESS '2-153 A\ga R.oad CITY ~cin\faS STATE DA ZIP tiJ2D2--1 CITY earls bad STATE CA ZIP q 2t()~ PHONE1(o0-15~-2A-b4 IFAX '100-153-0000 P1~0-b01-1 2-11 r AX EMAIL b , smrt1r)@,d-z..V\ pa,-t-ners.coWl EMAIL ken fA +reem, COM DESIGN PROFESSIONAL ~(1 r+-Sm i"\1r, / p Z N PaAYI e,r,;, CONTRACTOR BUS. NAME ADDRESS (o g L 5e£ond <;mer ADDRESS CITY E nci VI (-\-a 5 STATEC/\ ZIP 97.02~ CITY STATE ZIP PHONE1lo0-1'53-'2-41.a4 IFAX1(c;()-153-otoo PHONE 'FAX EMAILb . s-wiHiA@dz..V\ oo.r+V)€.YS. CDY'f) EMAIL . 12T~Ll~2ss, STATE UC.# !CLASS I CITY BUS. UC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct. alter, improve, demolish or repair any structure, prior to its issuance. also requires the applicant for such perm,t to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Wolllers' Compensation Declaratlon: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate or consent to self-Insure for workers· compensation as provided by Section 3700 of the Labof Code, for the performance of the worl( for which this permit is issued. D I have and will maintain wolllers' compensatlon, as reQuired by Section 3700 of the Labor Code, for the performance of lhe work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. ___________________ Policy No. _____________ Expiration Date ________ _ ~section need not be completed ~ the permit is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the performance of the worl( for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure wolllers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civtl fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. R$ CONTRACTOR SIGNATURE QAGENT DATE I hereby affirm that I am exempt from ContractlY's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation. will do the work and the slructure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's se Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did nol build or improve for the purpose of sale). • owner of the property, am exclusively contracting with ricensed contractors to construct lhe project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labof and materials for construction of the proposed property improvement. D Y es 0 No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have conlracted with the following person (firm) to provide the proposed construction (include name address / phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide lhe major work (include name / address/ phone I contractors' license number): 5. I will provide some of the work, but I ha tracted (hired) the llowing persons to provide the worl( indicated (include name/ address / phone / lype of work): R$ PROPERTY OWNER SIGNATURE •AGENT DATE Is the applicanl or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? • Yes • No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? • Yes • No Is the facility to be constructed within 1,000 feet or the outer boundary or a school site? • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. Lende(s Address I certifythatl have read the application and state that the above Information Is correct and that the information on the plans is aa:urate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for nspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY AY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is requred for excavations <Ner 5'0' deep and demolition constl\Jction 11\Jctures over 3 stories in height EXPIRATION: Every permtt issued by the Building Official u the provisions of is Code shan expI by . and become nul and void l the btJildilg orl'IO'k authorized by such permit is not commenced within 180days from the date of such permit or~ iding or · ed by tt issu o,!itxndQnl!o'ilfarn tine afterthel'IO'k is commenced for a period of 180days {Section 106.4.4 Uniform Building Code). _NS APPLICANT'S SIGNATURE DATE <g 14 J..011 June 12, 2018 Owner/Tenant 2153 ALGA RD Carlsbad CA 92009-6202 ( City of Carlsbad PERMIT NUMBER: CBR2017-1874 RE: BUILDING PERMIT EXPIRATION PERMIT TYPE: BLDG-Residential, Addition ISSUE DATE: 12/07/2017 ADDRESS: 2153 ALGA RD Our records indicate that your building permit will expire by limitation of time on 08/27/2018. 18.04.030 Section 105.5 amended -Expiration: Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 calendar days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 calendar days, or if the building or work authorized by such permit exceeds three calendar years from the issuance date of the permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 calendar days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any permittee holding an unexpired permit may apply for an extension of time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. Please check below indicating your intentions and return this letter to us. D Project abandoned. A new permit will be obtained prior to commencing work. D Permit 180 day extension request, with written explanation including phone number and email address. Request will not be considered without explanation D Renewal permit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760} 602-2725. If you have any questions, please contact the Building Inspection Division at 760-602-2700. Community & Economic Development Building Division I 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY REPORT (CBR2017-1874) Permit Type: BLDG-Residential Application Date: 08/15/2017 Owner: TRUST KAUFMAN KEN S TRUST 09-22-15 Work Class: Addition Issue Date: 12/07/2017 Subdivision: LA COSTA VALLEY UNIT#4 Status: Closed -Expired Expiration Date: 08/27/2018 Address: 2153 Alga Rd IVR Number: 5702 Carlsbad, CA 92009 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Date Start Date Complete 12/11/2017 12/11/2017 BLDG-SW-Pre-Con 042944-2017 Passed Andy Krogh Complete 12/29/2017 12/29/2017 BLDG-15 044634-2017 Passed Andy Krogh Complete Roof/ReRoof (Patio) 01/12/2018 01/12/2018 BLDG-13 Shear 045696-2018 Passed Andy Krogh Complete Panels/HD (ok to wrap) 02/05/2018 02/05/2018 BLDG-24 047582-2018 Passed Andy Krogh Complete Rough/Topout BLDG-34 Rough 047583-2018 Passed Andy Krogh Complete Electrical 02/09/2018 02/09/2018 BLDG-13 Shear 048423-2018 Failed Paul Burnette Reinspection Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 048421-2018 Failed Paul Burnette Reinspection Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-16 Insulation 048422-2018 Failed Paul Burnette Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/12/2018 02/12/2018 BLDG-13 Shear 048516-2018 Passed Andy Krogh Complete Panels/HD (ok to wrap) BLDG-16 Insulation 048515-2018 Passed Andy Krogh Complete 02/21/2018 02/21/2018 BLDG-17 Interior 049289-2018 Passed Andy Krogh Complete Lath/Drywall BLDG-18 Exterior 049498-2018 Passed Andy Krogh Complete Lath/Drywall 02/27/2018 02/27/2018 BLDG-17 Interior 049915-2018 Passed Andy Krogh Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Shower lath Yes September 27, 2018 Page 1 of 1 Structural Inspections LLC *SPECIAL INSPECTION SERVICES* P.O. Box 2415 El Cajon, CA 92021 Cell: (619) 770-9559 • Fax (619) 588-5955 Inspection Report Project Name: __ JL_()_w_F_rY'l __ -._,...,. ______ ----11T---------- ProjectAddress: __ "2-__ ,_~_~ __ .<\ __ \_&-,q ____ Q_} __ • ______ _ Page: ____ / of ( Report #: __ ()_f ___ _ Permit#: ( R t) L O I 7 {J 2 t, 0 Architect: ____ 'i) __ ?_~ __________________ _ File#: ________________ _ Engineer: _________________________ _ DSA#: ________________ _ Contractor: ________________________ _ Other: Hn-40 6.,, ,,ks INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST --Structural Steel --H.S. Bolts --H.S. Bolts --~ns/Specs --Masonry --Prisms --Cone. PSI --Clearances --Concrete --Mortar/Grout --Grout PSI --Positions --Fireproofing --Cone. Cylinders --Mortar PSI ~Sizes ✓ Epoxy --Fireproof _,,. Steel 7/t; 1 (/fl' .,q.r. Laps -- Other: Other: Elect./Wire Consolidation -------- --Other: --Other: --Fireproof __ Torque Ft. Lbs: --Other: --Other: ~ O ther: :X -P ,-Other: 7 ~0 f'" ..L_ I II / ,, ~ ,,~ ~-----Other: --Other: Other: ~ .J 0 Other: 5Peci A CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted. complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. I hen,by co«lfy ,ha< I ha~ obm~d ro <he bes< of my koowledge all of me abo~ ~poe<ed ~rl< ""'"' ome~l,e oo<ed. I h~ fo,od "''//4 ,omply wl<h <he app,o~d plao,, ,p,,lfl<atioo,, aod appllnble se«loo, of ,he ''"'""'"' b,lldlog ,_,. s / ;( Inspector: MARIO BATTAGLJA Cert: 350 ~ ~ / Pl 1/r Signature Date . lnsp. Date: Day I: Day 2: Day 3: Day 4: Day 5: Time Start: Time Stop: Approved By: ___________________ _ Project Superintendent EsGil Corporation In <Partnersliip witli (Jovernment for <Bui{aing Safety DATE: 8/25/2017 JURISDICTION: City of Carlsbad PLAN CHECK NO.: CBR2017-1874 PROJECT ADDRESS: 2153 Alga Rd. SET: I PROJECT NAME: Kaufman Residence Remodel & Addition • APPLICANT _JYJURIS. • PLAN REVIEWER • FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: ...(g-Telephone#: Date contacted : (by: 17lr Email: Mail Telephone Fax In Person ~ REMARKS: The inked clouded notes shown on sheet n.00 shall be made on the city I set. (at building department) ~ By: David Yao Enclosures: EsGil Corporation • GA • EJ • MB • PC 8/17 9320 Chesapeake Drive, Suite 208 • San Diego, Californ ia 921 23 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad CBR2017-1874 8/25/2017 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: David Yao BUILDING ADDRESS: 2153 Alga Rd. BUILDING OCCUPANCY: R3/U BUILDING AR EA PORTION ( Sq. Ft.) remdoel & add Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Bldg. Permit Fee by Ordinanc~ 3 Plan Check Fee by Ordinance 3 Valuation Multiplier By Ordinance Type of Review: 0 Complete Review D Repetitive Fee ~ Repeats • Other D Hourly EsGil Fee PLAN CHECK NO.: CBR2017-1874 DATE: 8/25/2017 Reg. VALUE ($) Mod . per city 53,700 53,700 $418.821 $272.231 D Structural Only 1-------11 Hr @ • $238.731 Comments: In addition to the above fee, an additional fee of $45 is due ( 1 hour @ $90/hr.) for the CalGreen review. Sheet 1 of 1 macvalue.doc + , ' {"Cityof Carlsbad PLAN CHECK REVIEW TRAN SM ITT AL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 08/22/2018 PROJECT NAME: KAUFMAN ADDITION PROJECT ID: PLAN CHECK NO: CBR2017-1874 SET: 1 ADDRESS: 2153 ALGA RD APN: 2152205600 VALUATION: $53,700 SCOPE OF WORK: ADD 252 SF • This plan check review is complete and has been APPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by Construction Management & Inspection Division is required: Yes No X This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: B.SMITH@DZNPARTNERS.COM To determine status by one of the divisions listed below, please contact 760-602-2719. LAND DEVELOPMENT 760-602-2750 Chris Glassen 760-602-2784 Christopher.Glassen@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov X ValRay Nelson 760-602-27 41 Va I Ray.Nelson@carlsbadca.gov Remarks: KAUFMAN ADDITION PLAN CHECK NO# CBR2017-1874 Please Read Instructions: Outstanding issues are marked with X Items that conform to permit requirements are marked with ✓ or have intentionally been left blank. FIX DIMENSIONS AND ADD EASEMENTS 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: X X ✓ North arrow ✓ Existing & proposed structures ✓ Existing street improvements Property lines (show all dimensions) Easements Right-of-way width & adjacent streets Driveway widths Existing or proposed sewer lateral Existing or proposed water service Submit on signed approved plans: DWG No. Show on site plan: Drainage patterns and proposed site elevations. Show all high points. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". Existing & proposed slopes and topography Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: ✓ Site address ✓ Assessor's parcel number Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: LOT 158 MAP 5781 Subdivision/Tract: LA COSTA VALLEY UNIT 4 Reference No(s): E-36 REV 6/01112 KAUFMAN ADDITION PLAN CHECK NO# CBR2017-1874 N/A N/A EXISTING E-36 2. DISCRETIONARY APPROVAL COMPLIANCE Project does not comply with the following engineering conditions of approval for project no.: 3. DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding$ 24 000 00 , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: 4. IMPROVEMENT REQUIREMENTS All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee, so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. Future public improvements required as follows: REV 6/01/12 KAUFMAN ADDITION PLAN CHECK NO# CBR2017-1874 E-36 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Grading Permit required . NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector The inspector will then provide the engineering counter with a release for the building permit. ✓ No grading permit required. Minor Grading Permit required. See additional comments for project-specific requirements. 6. MISCELLANEOUS PERMITS RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-way permit required for: Any work being done in public right of way requires a right of way permit, form E-11: http://www.ca rlsbadca .gov/services/building/forms/ default.asp Please allow for 2-3 w eeks of permit processing. REV 6/01/12 KAUFMAN ADDITION PLAN CHECK NO# CBR2017-1874 7. STORM WATER E-36 Construction Compliance Project Threat Assessment Form complete. Enclosed Project Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form and return (SW ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development BMP Design Manual Compliance Storm Water Standards Questionnaire. Project is subject to Standard Storm Water Requirements. See city Best Management Practices (BMP) Design Manual for reference. Indicate areas of impervious surfaces (patios.walkway, etc. ) and pervious areas (landscaping). Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: REV 6/01/12 KAUFMAN ADDITION PLAN CHECK NO# CBR2017-1874 Attachments: E-36 8. WATER METER REVIEW Domestic (potable) Use 9. FEES What size meter is required? FYI Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. FYI For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be¾". Required fees have been entered in building permit. Contact the Building division at (760) 602-2719 for a complete listing of fees Drainage fee applicable Added square feet Added square footage in last two years? Permit No. Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility Fire sprinklers required Upgrade ✓ No fees required yes yes no no yes yes yes yes no no no no 10. ADDITIONAL COMMENTS Engineering Application Storm Water Form Right-of-Way Application/Info. Reference Documents REV 6/01/12 *** Fee Calculation Worksheet *** ENGINEERING DIVISION Prepared by: Date: GEO DATA: LFMZ: / B&T: Address: Bldg. Permit#: Fees Update by: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Types of Use: Sq.Ft/Units Sq.Ft/Units Types of Use: Sq.Ft/Units Types of Use: Sq.Ft/Units ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft/Units Types of Use: Types of Use: Types of Use: FEES REQUIRED: Sq.Ft/Units Sq.Ft/Units Sq.Ft/Units EDU's: EDU's: EDU's: EDU's: ADT's: ADT's: ADT's: ADT's: Within CFO: YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) NO 1. PARK-IN-LIEU FEE: NW QUADRANT NE QUADRANT SE QUADRANT ;W QUADRANT ADT'S/UNITS: I X FEE/ADT: I =$ 2.TRAFFIC IMPACT FEE: ADT'S/UNITS: I X 3. BRIDGE & THOROUGHFARE FEE: (USE SANDAG)AOT'S/UNITS I X FEE/ADT: DIST. #1 FEE/ADT: 4. FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: 5. SEWER FEE EDU's BENEFIT AREA: EDU's 6. DRAINAGE FEES: ACRES: 7. POTABLE WATER FEES: I X FEE/SQ.FT./UNIT: 1x FEE/EDU: 1x FEE/EDU: PLDA: HIGH 1x FEE/AC: I=$ DIST.#2 I=$ I=$ I =s I =s MEDIUM I=$ LOW UNITS CODE CONN. FEE METER FEE SDCWA FEE ***This may not represent a comprehensive list off ees due for this project. DIST.#3 TOTAL Please contact the Building division at (760) 602-2719 for a complete listing off ees*** plan check comment response ENGINEERING DEPARTMENT DATE 2017.09-07 REVIEWER PROJECT ADDITIONS TO, AND REMODELING PROJECT ADDRESS OF, AN EXISTING TWO STORY SINGLE FAMILY RESIDENCE. ADDITION OF THE SECOND FLOOR MASTER BATH NEXT TO THE EXISTING MASTER BEDROOM IN THE LOCATION OF AN EXISTING BLACONY. THE BATHROOM WILL PROVIDE ACCESS TO EXTERIOR DECK. THE EXISTING MASTER BATH WILL BE REMODELED INTO AN OFFICE/DEN WHILE MAINTAINING AN ENTRY TO THE MASTER STAIR AND DRESSING ROOM. EXTERIOR DESIGN TO MATCH THE STYLE OF PROJECT# CBR2017-1874 PROJECT CONTACT RESPONSES BART M. SMITH, ARCHITECT Each correction has been addressed and referenced by the assigned correction number. ENGINEERING DEPARTMENT SITE PLAN See updated property lines with all dimensions on site plan, sheet a.00. 2 See easements on site plan, sheet a.00. ADDITIONAL COMMENTS Windows 06, 07, 08 have modified sizes and locations. 682 2nd St, Encinitas, CA 92024 1 of 1 p a r t n e r s VALRAY NELSON 2153 ALGA ROAD CARLSBAD, CA 92009 BART M. SMITH 760-753-2464 ~----------------------------------------------, ( City of Carlsbad STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue (760) 602-2750 www .ca rlsbadca .gov I INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the city requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMPs) into the project design per Carlsbad BMP Design Manual (BMP Manual). To view the BMP Manual, refer to the Engineering Standards (Volume 5). This questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'STANDARD PROJECT' requirements or be subject to 'PRIORITY DEVELOPMENT PROJECT' (PDP) requirements. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the city. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A completed and signed questionnaire must be submitted with each development project application. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. PROJECT INFORMATION PROJECT NAME: ken KaUf WJCLVl PROJECT ID: ADDRESS: J_\ t:)3 A\~4 Roctrl carlG~d, CA q200q APN: 2-1 5 -1-20 -5t,-00 The project is (check one): D New Development ® Redevelopment The total proposed disturbed area is: n ft2 ( ) acres The total proposed newly created and/or replaced impervious area is: 2.52--ft2 ( ) acres If your project is covered by an approved SWQMP as part of a larger development project, provide the project ID and the SWQMP # of the larger development project: Project ID SWQMP#: Then, go to Step 1 and follow the instructions. When completed, sign the form at the end and submit this with your application to the city. E-34 Page 1 of 4 REV 02/16 •\. ,. STEP 1 TO BE COMPLETED FOR ALL PROJECTS To determine if your project is a "development project", please answer the following question: YES NO Is your project LIMITED TO routine maintenance activity and/or repair/improvements to an existing building • ~ or structure that do not alter the size (See Section 1.3 of the BMP Design Manual for guidance)? If you answered "yes" to the above question, provide justification below then go to Step 5, mark the third box stating "my project is not a 'development project' and not subject to the requirements of the BMP manual" and complete applicant information. Justification/discussion: (e.g. the project includes only interior remodels within an existing building): If you answered "no" to the above question, the project is a 'development project', go to Step 2. STEP2 TO BE COMPLETED FOR ALL DEVELOPMENT PROJECTS To determine if your project is exempt from PDP requirements pursuant to MS4 Permit Provision E.3.b.(3), please answer the following questions: Is your project LIMITED to one or more of the following: YES NO 1. Constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet the following criteria: a) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or other non- erodible permeable areas; • ~ b) Designed and constructed to be hydraulically disconnected from paved streets or roads; c) Designed and constructed with permeable pavements or surfaces in accordance with USEPA Green Streets guidance? 2. Retrofitting or redeveloping existing paved alleys, streets, or roads that are designed and constructed in • ~ accordance with the USEPA Green Streets guidance? 3. Ground Mounted Solar Array that meets the criteria provided in section 1.4.2 of the BMP manual? • ~ If you answered "yes" to one or more of the above questions, provide discussion/justification below, then go to Step 5, mark the second box stating "my project is EXEMPT from PDP ... " and complete applicant information. Discussion to justify exemption ( e.g. the project redeveloping existing road designed and constructed in accordance with the USEPA Green Street guidance): If you answered "no" to the above questions, your project is not exempt from PDP, go to Step 3. E-34 Page 2 of 4 REV 04/17 ... •' STEP3 TO BE COMPLETED FOR ALL NEW OR REDEVELOPMENT PROJECTS To determine if your project is a PDP, please answer the following questions (MS4 Permit Provision E.3.b.(1 )): YES NO 1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces ~ collectively over the entire project site? This includes commercial, industrial, residential, mixed-use, • and oublic development projects on oublic or private land. 2. Is your project a redevelopment project creating and/or replacing 5,000 square feet or more of impervious surface collectively over the entire project site on an existing site of 10,000 square feet or • ~ more of impervious surface? This includes commercial, industrial, residential, mixed-use, and public develooment orojects on public or orivate land. 3. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface collectively over the entire project site and supports a restaurant? A restaurant is tJ a facility that sells prepared foods and drinks for consumption, including stationary lunch counters and • refreshment stands selling prepared foods and drinks for immediate consumption (Standard Industrial Classification (SIC) code 5812). 4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious ~ surface collectively over the entire project site and supports a hillside development project? A hillside • develooment oroject includes develooment on any natural slooe that is twenty-five percent or areater. 5. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface collectively over the entire project site and supports a parking lot? A parking lot is • ~ a land area or facility for the temporary parking or storage of motor vehicles used personally for business or for commerce. 6. Is your project a new or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious street, road, highway, freeway or driveway surface collectively over the entire project • ~ site? A street, road, highway, freeway or driveway is any paved impervious surface used for the transoortation of automobiles, trucks, motorcycles, and other vehicles. 7. Is your project a new or redevelopment project that creates and/or replaces 2,500 square feet or more of impervious surface collectively over the entire site, and discharges directly to an Environmentally ~ Sensitive Area (ESA)? "Discharging Directly to" includes flow that is conveyed overland a distance of • 200 feet or less from the project to the ESA, or conveyed in a pipe or open channel any distance as an isolated flow from the oroject to the ESA /i.e. not commingled with flows from adjacent lands).* 8. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious surface that supports an automotive repair shop? An automotive repair • ~ shop is a facility that is categorized in any one of the following Standard Industrial Classification (SIC) codes: 5013, 5014, 5541, 7532-7534, or 7536-7539. 9. Is your project a new development or redevelopment project that creates and/or replaces 5,000 square feet or more of impervious area that supports a retail gasoline outlet (RGO)? This category includes • ~ RGO's that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily Traffic {ADT> of 100 or more vehicles oer dav. 10. Is your project a new or redevelopment project that results in the disturbance of one or more acres of land and are expected to generate pollutants post construction? • ~ 11 . Is your project located within 200 feet of the Pacific Ocean and (1) creates 2,500 square feet or more of impervious surface or (2) increases impervious surface on the property by more than 10%? (CMG • ',g1 21 .203.040) If you answered "yes" to one or more of the above questions, your project is a PDP. If your project is a redevelopment project, go to step 4. If your project is a new project, go to step 5, check the first box stating "My project is a PDP ... " and complete applicant information. If you answered "no" to all of the above questions, your project is a 'STANDARD PROJECT.' Go to step 5 , check the second box statina "My project is a 'STANDARD PROJECT ... " and comolete applicant information. E-34 Page 3 of 4 REV 04/17 STEP4 TO BE COMPLETED FOR REDEVELOPMENT PROJECTS THAT ARE PRIORITY DEVELOPMENT PROJECTS (PDP) ONLY Complete the questions below regarding your redevelopment project (MS4 Permit Provision E.3.b.(2)): YES NO Does the redevelopment project result in the creation or replacement of impervious surface in an amount of less than 50% of the surface area of the previously existing development? Complete the percent impervious calculation below: Existing impervious area (A) = sq. ft. • )§ Total proposed newly created or replaced impervious area (B) = sq. ft. Percent impervious area created or replaced (B/A)*100 = % If you answered "yes", the structural BMPs required for PDP apply only to the creation or replacement of impervious surface and not the entire development. Go to step 5, check the first box stating "My project is a PDP ... " and complete applicant information. If you answered "no," the structural BM P's required for PDP apply to the entire development. Go to step 5, check the check the first box statinq "My project is a PDP ... " and complete applicant information. STEP 5 CHECK THE APPROPRIATE BOX AND COMPLETE APPLICANT INFORMATION D My project is a PDP and must comply with PDP stormwater requirements of the BMP Manual. I understand I must prepare a Storm Water Quality Management Plan (SWQMP) for submittal at time of application. ~My project is a 'STANDARD PROJECT' OR EXEMPT from PDP and must only comply with 'STANDARD PROJECT' stormwater requirements of the BMP Manual. As part of these requirements, I will submit a "Standard Project Requirement Checklist Form E-36" and incorporate low impact development strategies throughout my project. Note: For projects that are close to meeting the PDP threshold, staff may require detailed impervious area calculations and exhibits to verify if 'STANDARD PROJECT' stormwater requirements apply. D My Project is NOT a 'development project' and is not subject to the requirements of the BMP Manual. Applicant Information and Signature Box Applicant Name: Bae+ swi..c~ Applicant Title: A-rctH+ce-- 'i5 J 11 [ lD\1 Applicant Signature: b~ ----\~/?J Date: .. • Environmentally Sens1t1ve Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments): water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; Habitat Management Plan; and any other equivalent environmentally sensitive areas which have been identified by the City. T. B fi c · 0 his ox or ,tv Use nlv YES NO City Concurrence: • • By: Date: Project ID: E-34 Page 4 of 4 REV 04/17 PCSD Engineering Corp 3529 Coastview Court Carlsbad, CA 92010 Ph: 760-207-1885 - Structural Design Calculations Residential Addition Client Ken Kaufman 2153 Alga Road Carlsbad , CA 92009 Project on RCE C57182, exp. 12/31/17 July 24, 2017 PCSD File#: 17-250 ' t rPt.,r,1l V h.rut~n.Sl'.1"1 -~A,H Pt.La(! L »if1•1.urif't'J Paul Christenson San Diego Engineering 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 • Email: paul.pcsd@gmail.com 1.0 Design Criteria: Kaufman Residence 17-250 Code: Timber: 2016 California Building Code -ASCE 7-10 Douglas Fir-Larch (OF-L), WWPA or WCLIB 2x Wall Framing: DF-L #2 (unless noted otherwise) 2x Rafters & Joists: DF-L #2 " " Posts & Beams: DF-L #1 " " Glue-Lam Beams: Simple Span: Grade 24F-V4 (DF/DF) Grade 24F-V8 (DF/DF) Cantilevers: Sheathing: Min. APA-Rated Sheathing, Exposure 1, Plywood or OSB (U.N.0.) Engineered Framing Wood I-Joists: TJI 110,210,230,360,560 ICC ESR-1153 1.9E Microllam, 2.0E Parallam ICBO ER-4979 Concrete: Concrete Block: Mortar: Grout: LVL, PSL Compressive Strength @ 28 days per ASTM C39-96: Footings: f'c = 2500 psi Grade Beams: f'c = 3000 psi Grade N-1 per ASTM C90-95, f'm = 1500 psi per ASTM E447-92 Type S Mortar Cement per ASTM C270-95, Min. fm = 1800 psi @ 28 days. Coarse Grout w/ 3/8" Max. Aggregate per ASTM C476-91, Min. f'm = 2000 psi @ 28 days. Reinforcing Steel: #4 & Larger: #3 & Smaller: ASTM A615-60 (Fy = 60 ksi) ASTM A615-40 (Fy = 40 ksi) Structural Steel: 'W' Shapes: ASTM A992, Fy= 50-65 ksi Plates, Angles, Channels ASTM A36, Fy = 36 ksi Tube Shapes: ASTM A500, Grade B, Fy= 46 ksi Pipe Shapes: ASTM A53, Grade 8, Fy=35 ksi Welding Electrodes: Structural Steel: E70-T6 E90 Series Bolts: Soils: References: A615-60 Rebar: Sill Plate Anchor Botls & Threaded Rods: Steel Moment & Braced Frames: 1500 psf Bearing Pressure A307 Quality Minimum A325 (Bearing, U.N.O.) t?1 ,ru/f;,trz'.rteh.sv,:n 'ef,.,, xJz'!fo hJth6eTUIJ 3529 COastview Ct• Carlsbad, CA 92010 JOB 17-250 SHEET NO 'L OF -----CALCULATED BY PSC DATE 7/24/17 CHECK BY _____ DATE ___ _ SCALE Telephone (760) 207-1885. Email: paul.pcsd@gmail.com 2.0 LOAD LIST 2.1 Roof (Vaulted) Roofing 15/32" Sheathing Roof Framing 5/8" Gyp. Bd. rnsulation and Misc. loL = lLL = Total Load= 2.2 Roof {w/ ceiling) Roofing 15/32" Sheathing Roof Framing Insulation and Misc. 2.3 Ceiling Ceiling Joists loL = ~LL = Total Load= 5/8" Gyp. Bd. Insulation and Misc. 2.4 Walls loL = !u,= Total Load= Exterior Wall 7 /8" Stucco 15/32" Sheathing 2x4 Studs @ 16" o.c. 5/8" Gypsum Bd. Misc. 9.0 psf 1.5 psf 2.8 psf 2.8 psf 1.9 psf 18.0 psf 20.0 psf 38.0 psf 9.0 psf 1.5 psf 2.8 psf 1.7 psf 15.0 psf 20.0 psf 35.0 psf 1.3 psf 2.8 psf 1.9 psf 6.0 psf 10.0 psf 16.0 psf 9.0 psf 1.5 psf I. I psf 2.8 psf 0.6 psf 15.0 psf Interior Wall 1/2" Gyp. Bd. (2 Sides) 2x4 Studs @ 16" o.c. Misc. 4.6 psf 1.1 psf 2.3 psf 8.0 psf ? ,u/f;,tnde:/IJ'0:/1 ';In, ziu,JO hJUIIHJTVIJ 3529 Coastview Ct -Carlsbad, CA 92010 JOB 17-250 SHEET NO 1 OF CALCULA TED_B_Y __ P_S_C_ DAT-E---7..,.,/2_4_/1 __ 7_ CHECK BY DATE ---SCALE Telephone (760) 207-1885 -Email: paul.pcsd@ mail.com 2.0 LOAD LIST (CONTIN) 2.5 Floor Floor Cover Sheathing 2x F.J. 5/8" Gyp. Bd. lnsulation and Misc. 2.6 Wind Io1.,= I LL= Total Load= 5.5 psf 2.3 psf 3.5 psf 2.8 psf 0.9 psf 15.0 psf 40.0 psf 55.0 psf Ps = Al<zt-l*Ps30 (ASCE 7. Equation 6-1) P = 26.6 psf P = 16.0 psf (*0.6 -ASD) 2.7 Seismic SMS = 1.135 Sos= (2/3) SMS Sos = 0.757 s Cs= _o_s_ (R/1) Cs = 0.116 USE: V= 0.116 WoL ASD BASE SHEAR VAsn= C,WoL 1.4 VASo= 0.083 Wm. {11.4-3) WIND PARAMETERS Basic Wind Speed = 110 mph Exposure Cat = B A = 1.00 (fig. 6-3) Ps30 • 26.6 psf Kzt = 1.00 (fig. 6-4) I = l.0 (fig. 6-3) (table 11.5-1) uses APPLICATION s = s 1.051 S1 = 0.406 F = • 1.08 F = V 1.59 R = 6.5 l = 1.00 h,,= 25.00 Occupancy Category: 2 Site Class: D SEISMIC DESIGN CATEGORY S1 <.O 75 s, >0.04 Ss > 0.15 ( 11.6 ASCE 7-10) (11.4.l ASCE 7-10) Ta = C, * (hn)°" 75 = 0.224 Ts = S0 i/S0s _ 0.431 k = 1.0 Ta < (0.8)Ts, OK Ta<0.5 Seismic Design Category: D IIUSGS Design Maps Summary Report User-Specified Input Report Title Kaufman Mon July 24, 2017 21:24;56 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available In 2008) Site Coordinates 33.10109°N, 117.259°W Site Soil Classification Site Class D -"Stiff Soil" Risk Category I/II/III USGS-Provided Output S5 = 1.051 g S1 = 0.406 g SMS = 1.134 g S,41 = 0 .648 g 505 = 0.756 g S01 = 0.432 g Ft.,:. I, oso f"v: l,~i For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions In the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. ~ -·1,,·:i ~ ,:~""' ~ 'J.Vl .s ,:,.1() For PGAM, TL' cRS, and CR.1 values, please view the detajled report. Although this Information is a product of the U.S, Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the d11ta contained therein. This tool Is not a substitute for technical subject•matter knowledge. + 0 MEMBER REPORT Roof Framing, (RR-1) Rafters 1 piece(s) 2 x 6 Douglas Fir-Larch No. 2 @ 16" OC Overall Length: 10' 7" ill All locations are measured from the outside face of left support (or lel't cantilever end).AII dimensions are horizontal. + 0 ~~-~~~;_.-~~,~ -~~~~;,'~?::·· '.vjtitilf.Ui'.~ij'! 5,:;~';.·>;:,. ~~i-.:Y~~t'i~;r~ .:~; ;;•"' . .,,,.,,.,,...,.,_·• ·;,· ·:~~)~.f~:1:~~~~~ Member Reaction (tbs) 254@ 2 1/2" 3281 (3.50") Passed (8%) -1.0 D + 1.0 Lr (All Spans) Shear (lbs) 218@ 9" 1238 Passed (18%) 1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft·lbs) 620 @ 5' 3 1/2" 1060 Passed (59%) 1.25 1.0 D + 1.0 Lr (All Spans) Uve Load Dell. (In) 0.193@ 5' 3 1/2" 0.339 Passed (L/633) --1.0 D + 1.0 lr (All Spans) Total Load Defl. (in) 0.347 @ 5' 3 1/2" 0.508 Passed (L/352) .. 1.0 D + 1.0 Lr (All Spans) • Deflection Crlterlll: LL (l/360) and Tl (l/240). • Top Edge B111C1ng (Lu): Top CXlffll)ttSSlon edge must be braced at lO' 7" o(c unless detailed otne,w,se. • BoUom Edge Bracing (Lu): Botl0m compression edge roost be bnlced at 10· 7" o{c Lf'lless detailed otllerwtse. • A 15% Increase In ttie moment capacity has been added tx, account fQr repetitive member usage. • Applicable cakulations are baised on NOS. 2·Sludwall ·Df 3.so· 3.50" 1.so· 113 • 8Ioddng Panels are assumed to cany no loads applled dlrectty abo11e ttiem and the full load Is applled to the member being desq,ed. · Weyl!ltw!user waminls that the siting of~ products will be In accordance with W~sier product design criteria and published design ~-. : Weyerhaeuser-expressly disdllims any other warranties related to tile software. Use of tt,1$ soltware Is IVJt lntl!nded tx, clrrumVl!!flt the need (or a design ; professional as ctete<mlned by the au1hontv ha"1ng Jurisdiction. The designer of record, builder or frame< IS responsible to assure that this calculM!on IS · ~ wllh Ille Ol!fr.lll p,oject. Acc:es.soMs (RJm Board, 8loddng PMl!ls MVl 5qwlsll Blodis) ~ not designed~ lhls ~e. Products manufactlJred at Wey9rhaeoser t'acill!les are third-party certi!led IX) SUSbllnable foreslly standards. Weo,,erhaeus« Engineered wnt>er Products haYe been .,.,.lualled bV ICC ES under 1'eCMICal reports ESR-1153 and ESR· 1387 and/or tesbed In accordance wtlll ll!)pllcable ASTl-1 standards. For current code evaluaHon reports, Weyertvleuser product lltl!t'llture and lnstllllatlon details refer Ill www.weyfflHUser.com/woodprodueufdocurnent-llbrary. Tlle product aoplk:aden, i~ design loads, dlmens,ons and support Information have been provided by for1e SOltware Operator PA~ED System : Roof Membet'l"fpe: Joist 8ulldlng Use : Resldentiitl Building Code : !BC 20 l S Design Melhodology : IA.SD Member Pitch: 0/12 ~ SUSTAINABLE FORESm INITIATM Fofte Software Operator ~o••-------••-•·---•--••~-... -• ; Paul Chris,en,on . PCSO F n1;1ne<>r,ng ! (760) 207-1885 Jol>NOIH ---··-···-"·----·----------l I I I 7/25/2017 12:34:54 PM Forte v5.3. Design Engine: V7.0.0.5 Kaufman. 4te . J')lul re&d@gm~,I """" L ..... ___ ·-.. -·-····-·-·--·-·-·-.... ·-.. ·--· -··-··-"·· ..... _,,_., -··•-"-• , ___ ,,.,, ..... ·-·· -· ............ .l Page 1 of 1 ~,u/f;,tr/mm,on 'efDI fil'!fo hJ'net!TVIJ 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmall.com S.O Lateral Design & Analysis (Two-Story) Wind: P = A Kzt I psJO >..= 1.00 Kzt = 1.0 PS30 = 26.6 psf I = 1.0 P= 16.0 psf (ASC'E 7 -&1ua1icn /J.I) (fi~ !,-1) (fig 1,.·11 (lol,lc l l.Hl Criteria JOB 17-250 SHEET NO ( OF CALCULATED BY PSC DAT-E---7/ __ 2_4_/1 __ 7_ CHECK BY _____ DATE __ _ SCALE s = s 1.051 f= a I.I R= 6.50 (IBC Equation 12 .8-1 ) S1 = 0.406 f v= l.6 I = 1.00 V = 0.083 *Wt* p (p -Redundancy) 1st Storv 2nd Story Each Story Resists > 35% Base Shear: satisfied satisfied Wind Loads Any Shear Wall w/ (h/I)>1.0 is < 33% Story Force: P= 16.0 psfxTribArea Roof Level Direction: Direction: 2nd Floor Level Direction: Direction: Roof Weight RoofWt. = Exterior Wall Wt = Interior Wall Wt = Ceiling Wt Floor Weii:;ht Diaphragm = Exterior Wall Wt = Interior Wal] Wt = 1st Fir. Roof Wt. = N /S = 16.0 psf X 149 sq. ft.= E /W = 16.0 psf X 132 sq. ft.= N /S = 16.0 psf X 261 sq. ft.= E /W = 16.0 psf X 329 sq. ft.= 15.0 psf x 669 sq. ft.= 10035 lbs. 15.0 psf x 417 sq. ft.= 6255 lbs. 8.0 psf x 355 sq. ft.= 2840 lbs. 3.0 psf x 669 sq. ft.= 2007 lbs. ------Total Trib. WR = 21 137 lbs. 15.0 psf X 957 sq. ft. 14355 lbs. 15.0psf x 837 sq. ft. = 12555 lbs. 8.0 psf X 722 sq. ft. = 5776 lbs. 18.0 psf X 0 sq. ft. = 0 lbs. Total Trib. WR= 32686 lbs. Total Seismic Dead Load: Wt = 53823 lbs. ASD Base Shear: V = 0.083 * Wt = 4476 lbs. 2378 lbs. 2107 lbs. 4166 lbs. 5251 lbs. satisfied satisfied p = l I JOB 17-250 SHEET NO l, OF ~,u/&,tndlm.rc» ~m, 25,'rf" bJUteen'nJ --------CALCULATED BY PSC DATE CHECK BY DATE 3529 Coastview Ct -Carlsbad, CA 92010 SCALE Telephone {760) 207-1885 -Email: paul.pcsd@gmail.com Roof Diaphra2m: N I s Direction V = 2653 A= 669 f P = V/A = 3.97 Floor Diaphragm: N I S V= Direction 4166 A= fr =V/A= 957 4.35 lbs. sq. ft psf lbs. sq. ft psf ------Seismic Lateral Distribution V= 4476 lbs. Level Wx hx (lbs) (ft) Roof 21137 18 2nd Floor 32686 8 •p E /W Direction V = 2653 A= 669 f =V/A= p 3.97 E /W Direction V= 5251 A= 957 f =V/A = p 5.49 F Wx h,. w. O!.\ (lbs-ft) I w-k (lbs) 380466 0.593 2653 261488 0.407 1823 641954 1.000 4476 lbs. sq. ft psf lbs. sq. ft psf V (lbs) 2653 4476 7/24/17 --- ? ,u/f;',t~,o:n ';In, ,t'J,!?" £:nJV'eermJ 3529 Coastview Ct -Carlsbad, CA 92010 JOB 17-250 J OF ___ _ PSC DATE DATE 7/24/17 SHEET NO CALCULATED BY CHECK BY SCALE ----------- Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 5.1 Lateral Design & Analysis -2nd Story Shear Walls N /S E /W Gridlinc Length of Shearwalls Total Wall Ht. Type Gridline Length ofShearwnlls Total Wall l-lt. Type I 8 5 12.5 9 s A 10 9.5 9.25 s 2 16 16.0 9 s B 4 4 9.25 s 0.0 0 0.0 0 0.0 0 0.0 F SE 0 #~V/0! 0.0 F, E 0 # 1vto! 0.0 F SE 0 # /0! 0.0 F E 0 # V/01 0.0 F SE 0 IV/0! ~'1l$> JD,uff;.i"'n'.mm.l'on ~n, ,tji!f" JOB 17-250 SHEET NO f; OF SpeerutJ CALCULATED BY PSC DATE 7/24/17 ) -f\(~ CHECK BY DATE (:\;~, ~,~ ! ••• 'i,••'=-""~1 3529 Coastview Ct -Carlsbad, CA 92010 SCALE F'Mtl c4.riU.£,u"" !JA11-f>iu• ~"'"'ift' , Telephone (760) 207-1 885 -Email: paul.pcsd@gmail.com 5.1 Lateral Design & AnaJysi.s (coot.) Gridlinc ~ 20 % ( 2653 X 0.20 531 #) 531 lbs. & V "" 12.5 ft. "" 42 plf OTF = 393 lbs. ':.c, ~ "'o ~ Gridline 0 50 % ( 2653 X 0.50 1326 #) 1326 lbs ,~) ~ V = 16 ft. 83 plf OTF 766.8 lbs. ~"~Jllf> ? ,u/f;,tr/,den.,.,,n ;In, fi1y,, bJ'neerutJ 3529 Coastview Ct-Carlsbad, CA 92010 Telephone (760) 207-1885-Email: paul.pcsd@gmail.com 5.1 Lateral Design & Analysis (cont.) Gridline (]) 25 % ( 2653 X 0.25 663 #) 663 lbs. V = 9.5 ft. 70 plf OTF 645.7 lbs. Gridline Ci) 25 % ( 2653 X 0.25 663 #) 663 lbs. V = 4 ft. 166 plf OTF 1534 lbs. JOB 17-250 SHEET NO Ci OF ----CALCULATED BY PSC DATE 7/24/17 CHECKBY ____ DATE __ _ SCALE lb MST37 ~ MST37 ?,u/f;',+~n ';n, ~~., bfaet1mJ 3529 Coastview Ct -Carlsbad, CA 9201 0 JOB 17-250 \0 OF ------PSC DATE 7/24/17 DATE SHEET NO CALCULATED BY CHECK BY SCALE ----------- Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 5.2 Lateral Design & Analysis -1st Story Shear Walls N /S E /W Gridline Length of Shcarwalls Total Wall Ht. Type Crridline Length of Shcarwalls Total Wall Ht. Type 1 10 10 8 s A 2 2 8 D 2 14 14 8 A B 16 16 8 A 0 0 0 .0 0 0 0 0 #D 0! 0 # V/0! 0 #DI 70! 0 #D /0! 0 #DI 0! 0 # IV/0! 0 #1)[ /0! 0 #D ~/0! 0 #OIV/0! 0 # IV/0! )l!P ? ,u/f;',trl.,ten,o.n ~n, :dl'!f" JOB 17-250 SHEET NO OF bfaeerutJ CALCULATED BY PSC DATE 7/24/17 .,I ~\[:_ CHECK BY DATE ~-~ l~·~~~-!7 3529 Coastview Ct -Carlsbad, CA 92010 SCALE P#.14l ~"jf,r,,tjlll ..S....... ~-,...,,..,,,..., Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 5.2 Lateral Design & Analysis ( cont.) Gridline Q) 20 % ( 4166 x. 0.20 833 #) 833 lbs. + 531 & V = 10 ft. 136 plf OTF = 1091 lbs. USE 4x4 w/ HDU2 Gridline 0 50 % ( 4l66 x 0.50 2083 #) 2083 lbs. + 1326 ~ V = 14 ft. 243 plf G~ OTF' 1948 tbs. ? ,u/f;,f"',lmn.,.,,n 'Jn1 :IJl'!fo bfaeerutJ 3529 Coastview Ct• Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 5.2 Lateral Design & Analysis (cont.) Gridline (3) 15 % ( 5251 X 0.15 788 #) 788 lbs. + 663 V = 2 ft. 725 plf OTF 5803 lbs. Gridline 0 50 % 5251 X 0.50 2625 #) 2625 lbs. + 663 V 16 fl. = 206 plf JOB 17-250 · • SHEET NO \1.. OF ------,-,.~ CALCULATED BY PSC DATE 7/24/17 CHECK BY ____ DATE __ _ SCALE . . SIMPSON STRONG-TIE COMPANY INC. (800) 999-5099 SIMPSON 5956 W . Las Positas Blvd., Pleasanton, CA 94588. www.stronglie.com Strong-Tie ® ·---...... ___ ,, ____ __...., ____ ~-- Job Name: Kaufman Wall Name: Wall Line A Application: Standard Wall on Concrete Design Criteria: * 2015 International Bldg Code •Wind " 2500 psi concrete "ASD Design Shear= 1451 lbs Selected Strong-Wall® Panel Solution: } . . ·--.. ---.. -. ·-----~-- ! 1 Model Type W , H T ; Sill , l-··-···•--.. ·-· ·-----................. .'. _(i_~L ~ _Q_n) __ . {!~)_ ;-----~-~-h-~----ll_ I • I SW24x8 Wood 24 ! 93.25 3.5 . 2-5/8" l •.•• ----· ... -.• ---------....... -............ ·~·--··--. -· .•. ---· .... ~-.................. --..... • -·-·-... -.... • ·. Actual Shear & Drift Distribution: End Total Axial ; Anchor Load • ~(?ltS . _ • . . 11bs) .. 2 • 7/8" 2500 ! . . ... --. Actual AJiowable·· --, Acti:ial / {-Actual ' Drift i ! ----------------------~a~~'---------•-----·-.. ---~-_jrb~r__. ----~~;;: ..... ;---~~~---;---~~1. ____ ; ___ J~L-i L .. _ ............. ____ SW24x8 _ ... ------·-·-.L ... ~~~------~ ---~0_1~ .. '?~ .. _ o._12 _____ -~-3~ -~..:s~ __ ! 1-SW24x8 is OK. Notes: 1. Wood Strong-Wall Shearwalls have been evaluated to the 2015 IBC/IRC. See www.strongtie.com for additional design and installation information. 2. Anchor templates are recommended for proper anchor bolt placement, and are required in some jurisdictions. See program toolbar for detail under Tools I Anchor Bolt Templates. 3. The combined effect of the downward vertical axial load and overturning on the compression post of the Wood Strong-Wall shearwall shall be evaluated by the Specifier as not to exceed the "C4" Allowable Vertical Load. See Out of Plane and Axial Capacities In Tools dropdown menu. Disclaimer: Actual Uplift (!bs)_ 59661b It is the Designer's responsibility to verify product suitability under applicable building codes. In order to verify code listed applications please refer to the appropri.ite product code reports at \YWW.strongt1e.com or contact Simpson Strong-Tie Company Inc . .il 1-800-999-5099. Page 1 of 4 SIMPSON STRONG-TIE COMPANY INC. (800) 999-5099 5956 W. Las Positas Blvd., Pleasanton, CA 94588. www.strongtie.com t~/ SIMPSON ® ------•1-----------------------,.._"" ______ .._ ... ,: -·-..,_ . ..,._~_._, ______ _ Job Name: Kaufman Wall Name: Wall Line A Appllcatlon: Standard Wall on Concrete Design Criteria: • Slab on grade -Slab edge • 2015 International Bldg Code * Wind • 2500 psi concrete Anchor Solution Details: 1¾" 112---i----... -. -.,.:· =·= ..c omax. a5 l _J . . •:, .. l •• Slab Edge . .. ·" . . . ,.• • . . ... ,i • ·•. ,. . . • I Perspective View •• ·• • ... I , · .. 1 Slab not •• · ·: shown • : • • · "' 1 for clarity • •• A -~• ~-----] 4 • .. ' , I • • ' • 4 .. , .. · • . . · -12· ... .. . , .... .. ·, . l , ,I 4 tfl> • .... ... ~ 4 • • • Plan View ·Model-· -· · ·1..,~~~r·-;-: _. · ~... ... . .... · .-··· :· J'i!!l~~-~!~~-.([~·:i:,~~:_··.-.-.:~ -~ -_T:: -· :·~'!c:i~~-ie-r;n;io:~ L,_~;~~--Ot?s,L ·--.{ Curb Width ; Dlamete '. Length ! Min. Embed. (le) Midwall l Corner ! ·ssTB28 ~ ... 12 ·· ----;·o:S-rs·~----29.875·--··--2 4~s75·-···-·--·· .. -·-1·30ao··-··--:-· .... -13080 I .... _ .... -................... -·-L .... . .. ... • . . .. ... ... .. ... ,_ ....... ···-...... -----.... -. Notes: 1. Anchor design based on ICC-ES ESR-2611. 2. Wlnd includes Seismic Design Category A and B and detached one and two-family dwellings in SDC C. 3. Midwall loads apply when anchor is 1.5 le or greater from the end. For bolts acting in tension simultaneously, the minimum boJt center-to-center spacing is 3 le. 4. Footing dimensions are for anchorage only. Foundation design (size and reinforcement) by Designer. Page 2 of 4 . . SIMPSON STRONG-TIE COMPANY INC. (800) 999-5099 5956 W. Las Positas Blvd., Pleasanton, CA 94588. www.strongtie.com SIMPSON Strong'-Tie ~ ---.. ---·----~---··~---··--------... ------"--- Job Name: Kaufman WaJI Name: Wall Line A Application: Standard Wall on Concrete Design Criteria: • Slab on grade -Slab edge • 2015 International Bldg Code • Wind • 2500 psi concrete Anchor Solution Details: PAB7 5' Section at Slab Edge Anchor Solution Assuming Cracked Concrete Design: Model · W : de Anchor Bolt I ; I . . --··. --· -;----.. --·---;--· ! SW24x8 ' 16 . 6 i l ---··•·--··-···••A---·;, --. ..__ ....... ...,_ ....... •·• PAB7 Slab edge and surrounding foundation 3~~=~-1 . I ~-:~:~ Stroo~W•u [ no;sh>No tor ciarify I , . I • ______ _.__.__ _ __, I I I I I .. I ·, I ___ . _____ , _: ,. -·----._ I 1/i W I .I ½W 1.-.,~ s ---... f,e---e,.i ' ½ W S " Wall Length minus 73/• 1/2 W Slab Edge Footing Plan w Anchor Solution Assuming Uncracked Concrete Design: r·------~ ---, -~ -;' ;e ~---~n~ ;~t ··-------jij I I ' • ,,,,_,.,,.., '•• .. ••• •:• ;·H•-• •-•· --• • •·• -------4 L_ ____ S~2~x8 ___ .. _ )_ _1_4 . ; __ ~ .. ~ ... _______ ~~;8.7 ........ ___ _J Page 3 of 4 ? tm/f:,f'.rf.r&en,on eJ°.m Z)/'!f" £.F"'"""J 3529 Coastview Ct -Carlsbad, CA 92010 Telephone (760) 207-1885 -Email: paul.pcsd@gmail.com 6.0 FOUNDATION DESIGN 6.1 CONTTNUOUS FOOTING w= 1125 plf width = ~ plf 1500 psf 0.75 ft (MIN.) => 9 INCHES (MIN.) (E) 15 "WIDE CONTJN. FTG WI 1 -# 4 TOP A.~D BOTTOM & EMBED. 18 "INTO UNDISTURBED SOTL (MlN.) 6.2 MAX POINT LOAD ON FOOTING JOB 17-250 SHEET NO 14 OF ib CALCULATED BY PSC DATE 7f24/l7 --CHECK BY DATE ---SCALE ASBP = 1500 psf Pan= 1500 * ~ * ~ 12 12 P a11 = 7500 lbs F I STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP CBl<~O\l -{ f;7~ STORM WATER POLLUTION PREVENTION NOTES BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Stonm Water Waste Management and Materials 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE BMPs Control BMPs Management BMPs Pollution Control BMPs AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION C: -OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN C: C: 0 -0 0 :;::; C: C: -0 :;::; :;::; en C ., -0 ., -0 IS EMINENT. "' C: " " C: C: en E C: E C: -C :, :, 0 'o ·c: C. C C C E .; L L :;::; L ·5 >, ., ., THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION :,, -0 "' en L --C ·E '-en -., 2. L ., c "'"' "' C' L C C: "' en C: ., C. ., C: C: > L ., 0 C -CQ ·c. -;: -C: "' L '-" Lu > C: "' Best Management Practice* ~ C: C CD L 0 ., 0 ., C :;::; -3:-c-CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION "' L ., -~ ., :c "' "' C: f-., C C: UL u "' -0 "' ~ -0 "' :,, C: ., C: C: 3: C: (BMP) Description • "' " ., Cf) ·e ., E "' en ., en CD •o C en C: C: Cl :::, ~ -., "' ., ., OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING ., C C "' C: -0 Lu -0 >, C: C: C :g E " E " E :5 ~ Q) " -0 L 0 0"' C 0 ~ C: Cl CD Cf)·-en Cl:;:; .,, u ., en ., RAINFALL. :;::; :,, Cl en Cl C: ., 0:: _E C N <n 1:: C " cr,:.::; ., ., C: 0., 0 ·c. L-3: ., 0 ., -., X C ., .D E al = £/) =3 ~:;:; 15 o ·c ·cg ·c: ~_g en -o en ~ en ., E -"'-~ ., :, C: C -"'-i,c --0 .c C: ., I.,_ " L -0 :.a Q) ·--0 ., " •-L C 0, L ., " -0 C U C 0 0 -·-a. 'o ., ., ., :, C: L-CL .0 C -c ~~ -•-C -o -0 = C ·-C: N C: C: C: THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION LC -~ L () .s e .c ., 3. ., 0 CL 0 ., .c .D -c C -en .8 0 CL 0 ~G c_ C -C. 0 QC cc oc '-" 3: Lu Cl vi in ff) u c::: 0 Cf)> Cf) Cf) Cl.. Cf) C: Cf) 0:: 3: Cl.. CLO Cl.. :,, Cf) :,, Cf) Cf) u Cf):,, :r: :,, u:,, CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR CASQA Designation • r--co .... "' r--co 0 N .,., r--co N .,., .... '° "' co "' i i .,., '° i i I I I I I I I UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. I I I I I I I I I I I I I I :,, :,, :,, :,, :,, :,, :,, . u u u u Lu Lu Lu Lu Lu Lu Lu Lu gc: gc: Cf) ff) Cf) ff) Construction Activity Lu Lu Lu Lu Cf) Cf) Cf) ff) Cf) Cf) Cf) ff) z z z z 3: 3: 3: 3: 3: 3: 3: 4. ALL REMOVABLIE PROTECTIVE DEVICES SHALL BE IN PLACE Gradinn /Soil Disturbance AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) Trench in a /Excavation DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT Stockoilina ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER Drillin • /Borinq EACH RAINFALL. ltoncrete/Asohalt Sawcuttinq 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM Concrete Flatwork . / J 9avinq ' J AGGREGATE. .. 'Conduit/Pioe Installation ,I ✓ 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER " Stucco/Mortar Work ✓ ' / PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST \a Waste Disoosal BE INSTALLED AND MAINTAINED. Staainn /Lav Down Area Equipment Maintenance and Fuelin• 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER Hazardous Substance Use/Storaqe THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED Dewaterina TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY Site Access Across Dirt REGULATIONS. other !list): Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BMP's with it's corres~onding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check he box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION PROJECT INFORMATION f2oaJ ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID Site Address: 1 / '5 3 .A ~0-THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSlRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, Assessor's Parcel Number: COMPLY WITH THIS CITY APPROVED TIER 1 CONSlRUCTION SWPPP Emergency Contact: THROUGHOUT THE DURATION OF THE CONSlRUCTION ACTIVITIES UNTIL THE CONSlRUCTION WORK IS COMPLETE AND APPROVED Name: 1'£j ~~M(A"1 BY THE CITY OF CARLSBAD. ~ /J uhl1-:r- 24 Hour Phone: = 6-_=j, 01"• 1' A :J--:}- ~ ~7hT NAME (PRINT) Construction Threat to Storm Water Quality (Check Box) OYVM::t<\SJ/OWNER S AGENT NAME (SIGNATURE) DATE ~EDIUM • LOW E-29 Page 1 of 1 ' REV 11/17 Print Date: 03/11/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2153 Alga Rd BLDG-Permit Revision 2152205600 $ 0.00 Revision Permit Work Class: Residential Permit Revisi Lot#: Reference #: Construction Type Bathrooms: Orig. Plan Check#: CBR2017-1874 Plan Check #: Description: KAUFMAN: CHANGES TO WINDOW SIZE AND LOCATION Applicant: DZN PARTNERS BART SMITH 682 2Nd St Encinitas, CA 92024-3560 760-753-2464 FEE MANUAL BUILDING PLAN CHECK FEE Total Fees: $ 150.00 Building Division Owner: TRUST KAUFMAN KEN S TRUST 09-22-15 2153 Alga Rd CARLSBAD,CA 92009 Total Payments To Date : $ 150.00 (city of Carlsbad Permit No: PREV2017-0200 Status: Applied: Issued: Permit Fina led: Inspector: Final Inspection: Closed · Expired 09/11/2017 12/07/2017 AKrog AMOUNT $150.00 Balance Due: $0.00 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {_ City of Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APPLICATION Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov B-15 Original Plan Check Number Ci312-.2.0I 1 -l'b 14 Plan Revision NumberPR.£.V2..011-O2.CXJ Project Address 2.1'53 A1ge1 l<.OC\d Car15bad J CA q LOO Cf General Scope of Revision/Deferred Submittal: Mocl1£(a-hov1 of' Size c:xv.d IC>G!t'lon +o \NiV1dows o'-o1 o~ oS?. CONTACT INFORMATION: Name E:>a.r+ Smittn Phone li.,0 -153-2404 Fax 100-1S3--0(oOO Address {oi Z-6e(()()d 'St-ree-+ City \::)1G\.Y)ltaS Zip CJ :20 21- Email Address b' SrYlli"vl@dZ.Vl pa-r+vius-com Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: ~ Plans D Calculations D Soils D Energy D Other 2. Describe revisions in detail W\/lfVII/\) <:. n1a.01.o'6 ll'Vl/\,11'+, ect g,1oc 11,11rl \Q(/'H,'/\\1\ <: n V\ ao r11,r, r\ r \N,f' VY\ Cl 5-\eY ',:::) OtiA I Ali'! J I 4. 5. 6. Does this revision, in any way, alter the exterior of the project? lZJ Yes Does this revision add ANY new floor area(s)? D Yes Does this revision affect any fire related issues? D Yes KJ No fil" No 3. List page{s) where each revision is shown (\, o4 . n ,05, a,01 ct,0'3'1 Sl I T2.1 0 No 7 • Is this a complete set? ~ Ye[C:'O No ,@'.$'Signature Q ~:d:i ~_.-\..,.~-Date oq_/01 j 2.011 1635 Faraday Avenue, Carlsbad, CA 92008 ft]: 7 60-602-2719 Eax: 7 60-602-8558 Emilit building@carlsbadca.gov www.carlsbadca.gov