HomeMy WebLinkAbout2155 SALK AVE; ; CB072905; Permit12-21-2007
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB072905
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
2155SALKAVCBAD
Tl Sub Type
2121304100 Lot#
$20 300 00 Construction Type
Reference #
TAYLOR MADE 580 SF REMODEL OF
OFFICE SPACE
COMM
0
NEW
Applicant
KINOSHITA MICHAEL
STE 207
7510 CLAIREMONT MESA BLVD
SAN DIEGO CA 92111
858268 8176
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Plan Check#
ISSUED
11/16/2007
KG
12/21/2007
12/21/2007
Owner -
T M G PROPERTY
1000 PIONEER WAY
EL CAJON CA 92020
Building Permit
Add I Building Permit Fee
Plan Check
Add I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add I Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add I Pot Water Con Fee
Reel Water Con Fee
$201 15 Meter Size
$0 00 Add I Reel Water Con Fee
$13075 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$426 PFF (3105540)
$0 00 PFF (4305540)
$0 00 License Tax (3104193)
$0 00 License Tax (4304193)
$000 Traffic Impact Fee (3105541)
$0 00 Traffic I mpact Fee (4305541)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 * MECHANICAL TOTAL
$000 'Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
HMP Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$3500
$2400
$000
$000
$000
$000
77
$395 16
Total Fees $395 16 Total Payments To Date $395 16 Balance Due $000
BUILDING PLANS
<. IN STORAGE
_ ATTACHED
Inspector
FINAL
Date
VAL.,
0*Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively
referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
1635 Faraday Ave Carlsbad CA 92008
760 602 2717 / 2718 / 2719
Fax 7606028558
Building Permit Application
CONTACT NAME (If Different Fom Applicant)
' / yy ' *^ \^/ / /—-» -~
(Sec 7031S Business and Professions Code Any City or County which requires a permit to construct, alter, improve demolish or repair-any structure, pnor to its issuance also requires the applicant for such permit to file 9 signed statement that he is
licensed pursuant to the provisions of the Contractor s License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom and the basis for the alleged exemption Any violation of
Section 7031S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500})
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the fallowing declarations
n I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued
I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers compensation insurance carrier and policy
number are Insurance Co .STftTg pU-^fl Policy No 6OC%%'&0* •^°C ' Expiration Date t O / » | O 8
This section need not be completed if the permit is for one hundred dollars ($100) or less
d Certificate of Exemption I certify that in the performa|)«6"of the work for wfitctHtasoermit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of
California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100 000) In
Sddition to the rmt nfrnrjinrn-ffinTrrrfflmnqn m prmflflnrifor injSrrtmn 3706 oftbeaabor code interest and attorney s fees
DATE
/ hereby affirm that I am exempt from Contractor s License Law for the following reason
O I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for
sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
O I as owner of the property am exclusively contracting with licensed contractors to construct the proiect (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of
property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law)
O I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D Yes D No
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address /phone / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work)
j£TpROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the
Presley Tanner Hazardous Substance Account AcP D Yes O No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 D Yes D No
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site7 O Yes O No
IF ANY OF THE ANSWERS ARE YES
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code)
Lender s Name Lender s Address
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction
yiereby authonze representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height
EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within
180 days from the date of such perm
^APPLICANT S SIGNATURE
City of Carlsbad Bldg Inspection Request
For 03/19/2008
Permit* CB072905
Title TAYLOR MADE-580 SF REMODEL OF
Description OFFICE SPACE
Inspector Assignment PD
Type Tl Sub Type COMM
Job Address 2155SALKAV
Suite
Location
OWNER T M G PROPERTY
Owner T M G PROPERTY
Remarks
Lot
Phone 8584142781
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By KEVIN
Entered By CHRISTINE
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
PCR05062 ISSUED IAYIOKMADI GOI I RIVIO KM I AYOU I AND ADDING 2 MORI Ol HCI S
PCR05132 ISSUED I AYI OR MAD1 GOI I Rl V POS IS III ADF RS & DOORS
Inspection History
Date Description Act Insp Comments
01/28/2008 89 Final Combo NR PD OK TO OCCUPY/GLASS @ DOORS
01/24/2008 49 Final Mechanical CA PD
01/23/2008 84 Rough Combo AP PD CEILING
12/27/2007 17 Interior Lath/Drywall AP PD
12/27/2007 84 Rough Combo AP PD WALLS
EsGil Corporation
In Partnership with government for <Buifding Safety
DATE December 18, 2007
JURISDICTION Carlsbad
PLAN CHECK NO 07-2905
PROJECT ADDRESS 2155 Salk Avenue
PROJECT NAME The Kingdom TI
APELJCANT
JLJRISl
a FILE
SET III
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted
Date contacted
Mail Telephone
REMARKS
(by )
Fax In Person
By Bryan Zuppiger
Esgil Corporation
GA D MB D EJ ' D PC LOG
Telephone #
Fax#
Enclosures
^trnsmtl dot
s
9320 Chesapeake Drive Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
EsGil Corporation
In (Partners/tip with government for (BmCding Safety
DATE December 13, 2007
JURISDICTION Carlsbad
a FILE
PLAN CHECK NO 07-29O5 SET II
PROJECT ADDRESS 2155 Salk Avenue
PROJECT NAME The Kingdom TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Michael Kmoshita
7510 Clairemont Mesa Boulevard, Suite #207
San Diego, CA 92111
Esgil Corporation staff did not advise the applicant that the plan check has been completed
X] Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Michael Kmoshita Telephones 8582688176
Date contacted W2/°(by d&fy Fax# 8582688177
Mail (/ Telephone Fax x'ln Person
REMARKS
By Bryan Zuppiger Enclosures
Esgil Corporation
D GA D MB D EJ D PC 12/06/2007
trnsmtl dot
9320 Chesapeake Drive, Suite 208 + San Diego California 92123 +• (858)560-1468 + Fax (858) 560-1576
Carlsbad O7-29O5
December 13, 2OO7
RECHECK PLAN CORRECTION LIST
JURISDICTION Carlsbad
PROJECT ADDRESS 2155 Salk Avenue
DATE PLAN RECEIVED BY
ESGIL CORPORATION 12/06/2007
REVIEWED BY Bryan Zuppiger
PLAN CHECK NO 07-29O5
SET II
DATE RECHECK COMPLETED
December 13, 2007
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is based on
regulations enforced by the Building Department You may have other corrections based on laws and
ordinances enforced by the Planning Department, Engineering Department or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997
Uniform Building Code, the approval of the plans does not permit the violation of any state, county or
city law
A Please make all corrections on the original tracings and submit new sets of prints to
sheet
See #1 next
B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the revised
plans
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of the prior
correction list, we have enclosed those pages containing the outstanding corrections Please
contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where they
are located on the plans Have changes been made not resulting from this list?
QYes QNo
Carlsbad 07-29O5
December 13, 2O07
• PLANS
NOTE The items listed below refer to the item numbers from previous list These
remaining items have not been adequately addressed The notes in bold at the end of or
contained within each item are to emphasize the remaining problem
1 Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
6 Provide complete energy designs for the proposed changes in envelope, lighting, and
mechanical systems Provide the completed ENV-, LTG-, and MECH-forms showing
energy compliance
8 The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the
plans
• Please complete the lighting controls sheets, Sheet LTG-1-C,
o Please sign the 1st sheet in both places and check the appropriate boxes on the
plans Sheet LTG-1-C Parti of 4
o Complete the mandatory automatic controls form on the plans Sheet LTG-1-C Part
2 of 4
o Complete the certificate of compliance state the equipment to be tested and the
persons doing the testing on the plans Sheet LTG-1-C Part 4 of 4
o Please detail the method of compliance on the plans
o Please fill-out the LTG-MM and imprint on the plans
• Please complete the mechanical controls sheets, Sheet MECH-1-C,
o Please sign the 1st sheet in both places and check the appropriate boxes on the
plans Sheet MECH-1-C Parti of 4
o Complete the certificate of compliance state the equipment to be tested and the
persons doing the testing on the plans Sheet MECH-1-C Part 1 of 2
o Please fill-out MECH-MM and imprint on the plans
Carlsbad 07-2905
December 13, 2007
The person responsible for their preparation must sign all final sheets of plans (California
Business and Professions Code)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contact Bryan Zuppiger at Esgil Corporation Thank you
EsGil Corporation
In Partnership with government for <BuiCding Safety
DATE November 29, 2007
JURISDICTION Carlsbad
PLAN CHECK NO 07-2905 SET I
PROJECT ADDRESS 2155 Salk Avenue
PROJECT NAME The Kingdom TI
a ANT
LI PLAN REVIEWER
a FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Michael Kmoshita
7510 Clairemont Mesa Boulevard, Suite #207
San Diego, CA92111
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Michael Kmoshita Telephone # 858 268 8176
Date contacted ltlz'W0$yd£& ) Fax# 858 268 8177
Mail Telephone \/ Fax j/fn Person
REMARKS
By Bryan Zuppiger
Esgil Corporation
D GA D MB D EJ D PC
Enclosures
11/20/2007
trnsmtl dot
9320 Chesapeake Drive Suite 208 4 San Diego California 92123 * (858)560-1468 *• Fax (858) 560-1576
Carlsbad 07-2905
November 29, 2007
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO O7-29O5
OCCUPANCY B
TYPE OF CONSTRUCTION VN
SPRINKLERS'? yes
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED November 29, 2007
JURISDICTION Carlsbad
USE office
ACTUAL AREA 580 ft2
OCCUPANT LOAD 5
DATE PLANS RECEIVED BY
ESGIL CORPORATION 11/2O/2007
PLAN REVIEWER Bryan Zuppiger
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review is
based on regulations enforced by the Building Department You may have other corrections based
on laws and ordinances enforced by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to the
issuance of a building permit
Code sections cited are based on the 2001 CBC that adopts the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997
Uniform Building Code, the approval of the plans does not permit the violation of any state, county or
city law
To speed up the recheck process, please note on this list (or a copy) where each correction
item has been addressed, i e , plan sheet number, specification section, etc Be sure to
enclose the marked up list when you submit the revised plans
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
Carlsbad 07-29O5
November 29, 20O7
• PLANS
1 Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
2 Please sign the accessibility certification on the Cover Sheet of the plans or submit
accessibility details
3 Please reference the Wall Section on Sheet A2 to the floor plan/wall legend
4 Please assign all details on Sheet A2
5 Provide plans, calculations and worksheets to show compliance with current energy standards
for the bay to office conversions
6 Provide complete energy designs for the proposed changes in envelope, lighting, and
mechanical systems Provide the completed ENV-, LTG-, and MECH- forms showing energy
compliance
7 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as
per the energy design
8 The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans
The person responsible for their preparation must sign all final sheets of plans (California
Business and Professions Code)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contact Bryan Zuppiger at Esgil Corporation Thank you
Carlsbad 07-29O5
November 29, 20O7
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Bryan Zuppiger
BUILDING ADDRESS 2155 Salk Avenue
BUILDING OCCUPANCY B
PLAN CHECK NO O7-2905
DATE November 29, 2007
TYPE OF CONSTRUCTION VN
BUILDING
PORTION
ti
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
580
cb
RIHn Ppi-mit Fpa hu CVHinanro ^
Valuation
Multiplier
3437
By Ordinance
Reg
Mod
VALUE ($)
19,935
19,935
$19275
Plan Check Fee by Ordinance
Type of Review
L"H Repetitive FeeRepeats
Complete Review
D Other
I-, Hourly
Structural Only
Hour*
Esgil Plan Review Fee
$12529
$10794
Comments
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB07~3-Cf 05 DATE //-/9-71
ADDRESS
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER Ji
PLANNER
ENGINEER
DATE
DATE
Oocs/MUfarms/Planning Engineenng Approvals
Carlsb.ad[ Fire Department BLDG DEPTCOPY
Plan Review Requirements Category TI, COMM
Date of Report 11-21-2007
Name
Address
Reviewed by
Permit # CB072905
Job Name TAYLOR MADE-5 80 SF REMODEL OF
Job Address 2155 S ALK A V CB AD
adequate hycondua
carefully all minim
item you have submitted for review is incompjetp
codes and/or standards Please review
iT'vilimit tin necessary plans' 'anff^fPlpfgiliLaUUii^
and approval
Conditions
Cond CON0002459
[MET]
APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Entry 11/21/2007 By MS Action AP
TITLE 24 REPORT
Title 24 Report for
The Kingdom - Bay 2 & 3
2155 Salk Avenue
Carlsbad, CA 92008
Project Designer
MKA Inc Architecture & Planning
7510 Clairmont Mesa Boulevard, Suite 207
San Diego, CA 92111
(858)268-8176
Report Prepared By
Wayne Seward, NR05-03-5612
Bear Technologys
7774 Calle Mejor
Carlsbad, CA 92009
(760) 635-2327
Job Number
7Q4048
Date
12/14/2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards
This program developed by EnergySoft LLC www energysoft com
EnergyPro 4 3 by EnergySoft Job Number 7Q4048 User Number 5956