2165 CORTE ACEBO; ; CB081607; Permit
08-20-2008 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Mechanical Permit Permit No CB081607 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # PC# Project Title 2165 CORTE ACEBO CBAD MECH 2552600800 $000 GELLER RES ADD A/C UNIT PRE-PLUMBED Applicant MAJOR LEAGUE HEATING & AIR CONDITIONING 1356 BOBOLINK DRIVE VISTA 92083 Status Lot # 0 Applied Entered By Plan Approved Issued Inspect Area Owner GELLER FAMILY TRUST 01-23-01 2165 CORTE ACEBO CARLSBAD CA 92009 ISSUED 08/20/2008 KG 08/20/2008 08/20/2008 Mechanical Issue Fee Install/Furn/Ducts/Heat Pumps Fee Fireplace Installation Fee Exhaust Fan Fee Installation/Relocation Vent Fee Hood Fee Boiler/Compressor to 15HP Fee Other Additional Fees TOTAL PERMIT FEES 1 0 0 0 0 0 $1500 $900 $000 $000 $000 $000 $000 $000 $000 $2400 Total Fees $24 00 Total Payments To Date $24 00 Balance Due $000 Inspector FINAL APPROVAL Date H/ i'Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these feer/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this projpct NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise exoired City of Carlsbad 1635 Faraday Ave , Carlsbad, CA 92008 760-602-2717/2718/2719 Fax 760-602-8558 Building Permit Application Plan Check N Est. Value Plan Ck. Deposit Date i CT/P I DESCRIPTION OF'WOi # OF UNITS # BEDROOMS|#E SUITE(t/SPACE#/UNIT# # BATHROOMS ~ ["TENANT" BUSINESS NAME (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter improve demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is Contractors License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption Any violation of , licensed pursuant to the provision! of the Contractors License Law {Chapter 9 commending with Section 7000 of Division 3 of the Bus Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than Five hundred dollars {$500}) 1 Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations L~) I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued j ^4l I have and will maintain workers'compensation as required by Serton 3700 of the Labor Code for the performance of thejvork.fo which this,permit is issued Myworkers compensation^nsurance ca/ner aj I number are Insurance Co-^^-i-i J*i I f^r^vi^f^ ^jtZ^sf^jQ (—^~& Policy No rr/Jrv &$=>)£) x cr£*> ~r~ Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less O Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Sectioru3706 of the Labor code, interest and attorney's fees | ^CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor s License Law for the following reason d I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) JO I as owner of the property am exclusively contracting with licensed contractors to construct the proiect (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of properly who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) CI \ am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed properly improvement d Yes d No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have conlracled with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name.' address / phone / type of work) ) PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act7 d Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' d Yes d No Is Ihe facility lo be constructed within 1 000 feet of the outer boundary of a school site' d Yes d No IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender s Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction thereby authonze representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the Building Official under (tie provisions of (his Code shall expire by limitation and become null and void if Ihe building or work auDionzed by such permit is not commenced within 180 days from the date of such pemnit orjf the'b'uilding or work authonzed by such permit is suspended or abandoned at any tme after the work is commenced for a penod of 180 days (Section 106 4 4 Uniform Building Code) >€$"APPLICANT'S SIGNATURE DATE UNSCHEDULED BUILDING INSPECTION y AM 4*0 DATE te KJbVl Qg> INSPECTOR PERMIT # &> ° &( &>1 PLAN CHECK # JOB ADDRESS DESCRIPTION CODE DESCRIPTION ACT COMMENTS 6° City of Carlsbad Bldg Inspection Request For 09/17/2008 Permit* CB081607 Inspector Assignment Title GELLER RES ADD A/C UNIT | [ ^ £-? Description PRE-PLUMBED Type MECH Sub Type Phone 7605188300 Job Address 2165 CORTE ACEBO Suite Lot 0 Location Inspector \/\,C APPLICANT MAJOR LEAGUE HEATING & AIR CONDITIONING Owner GELLER FAMILY TRUST 01-23-01 Remarks Total Time Requested By MICHEL Entered By CHRISTINE CD Description Act Comments 43 AirCond/Furnace Set Comments/Notices/Holds - ~\. Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments A-w- CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME A FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE'? L YES FOR FURTHER INFORMATION, CONTACT. PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER (10/30/2008) Peter Dreibelbis - TEXT htm _ '""/ "' ^ "" Page i" Hello Mr Foss, Thank you for taking the time to speak with me yesterday afternoon, regarding the concerns expressed on the electrical requirements specifically for Trane 5 ton condensing units using refrigerant R-410a My position is technical support, and I hope to clarify a frequent question with regard to MOCP relating to residential HVAC units To recap, this is regarding the maximum overcurrent protection is.sue on the Trane model # 4TTX5060A1000A condensing unit installed at the residence of Mi Mickey Geller, 2165 Corte Acebo, Carlsbad, CA, by Major League Heating and Air Conditioning, based in Vista The permit # is CB081607 The condensing unit minimum and maximum valuer are posted as the same, at 60 A, with a minimum circuit ampacity at 36 A My understanding is there is an 8 AWG wire between the circuit breaker panel and the condensing unit disconnect Assuming the wire insulation is such that this wire is rated for 50 amperes of current, this satisfies the MCA of 36 (See attached "Service Facts" which are included in every Trane unit manufactured This provides the technical specifics needed for the installer and service technician) See also the attached NEC Table 310 16 I believe the impasse here is how there can be a 60A circuit breaker can be permissible using a wire which is only rated for 50 A According to the 2005 NEC Article 440 22 "Rating or Setting for Individual Motor-Compressor The motor-compressor branch-circuit short- circuit and ground-fault protective device shall be capable of carrying the starting current of the motor A protective device having a rating or setting not exceeding 175 percent of the motor- compressor rated-load current or branch-circuit selection current, whichever is greater, shall be permitted, provided that, where the protection specified is not sufficient for the starting current of the motor, the rating or setting shall be permitted to be increased but shall not exceed 225 percent of the motor rated-load current or branch-circuit selection current, whichever is greater" An interpretation of this is the breaker, providing it will not open under normal starting conditions may be sized not greater that 175 % of the electrical load, however, if the compressor will experience nuisance trips, (determined by all HVAC manufacturers ) the breaker may be increased to as high as 225 % of the electrical load Furthermore, if the calculated number matches that of a non-common breaker, Trane will calculate the risks of nuisance trips by using a common size breaker If it will work under normal operation, Trane will typically show this as being "MIN " breaker size Case in point The unit at the Geller residence is a Trane model 4TTX5060A1000A The attached "Service Facts" state the compressor RLA @ 26 4 A, condenser fan @ 2 8 A (10/30/2008) Peter Dreibelbis - TEXT htm ' ": '.7.ZIIZ.- Page 2 I MCA calculation- Using the compressor RLA, 26 4, and multiply by 1 25 = 33 0 A Add the fan motor amperage (2 8 A) for the sum of 35 8 A, or 36 A as the MCA The wire gauge from the panel to the disconnect shall not have an ampacity less than this value II WlIN / MAX calculation- Please refer to the underlined text above for this example Using the compressor RLA, 26 4, multiply by 1 75 (175%) = 46 20 A Add the condenser fan amperage (2 8 A) for the sum of 49 0 A The calculation would appear to offer a 50A breaker, however Trane implies by not listing a 50 A "MIN" that use of such could lead to this nuisance condition Therefore, using " the rating or setting shall be permitted to be increased but shall not exceed 225% " that is, compressor RLA 26 4 A X 2 25 (225%) = 59 4 A Add the condenser fan once again and we are at the MAX of a 60A circuit breaker (Refer back to the underlined above ) This is why the MIN/MAX are listed as the same, 60A, with a MCA at 36 A A key point here which should be emphasized is that the compressor is internally protected If the compressor were to experience an overcurrent condition, other than a direct winding short or short to ground, it is likely to cycle upon it's own internal overload prior to tripping the circuit breaker If there were no internal overload protection, then I would readily agree that a 60A breaker is not suitable for a 50A service Too, if the MIN 60A rating were to cause the MCA to be increased, it would bo reflected in the product specifications In conclusion, a gauge wire capable of sustaining 50 amperes of current should be permissible with the 60 A overcurrent protection, according to interpretation of the NEC Article Thank you for your time and attention, and please let me know your decision as Major League Heating & Air Conditioning is stating the permit is not finalized due to this very concern Smce'rely, Wayne DeCosa Trane FSR Ferguson Heating & Cooling, Inc Wolseley North American Division (10/30/2008) Peter Dreibelbis - TEXT htm " --••••-••• Page 3 714-709-7904 TRANE 4TTX5060-SF-1 Split System Cooling 4TTX5060A1000A A CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22 PROPER SERVICE EQUIPMENT IS REQUIRED FAILURE TO USE PROPER SERVICE TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR PERSONAL INJURY SERVICE USE ONLY R-41OA REFRIGERANT AND APPROVED POE COMPRESSOR OIL IMPORTANT — This document contains a wiring diagram, a parts list, and service information This is customer property and is to remain with this unit Please return to service information pack upon completion of work A WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE I I CAPACITORS BEFORE SERVICING PRODUCT SPECIFICATIONS OUTDOOR UNIT ©@ 4TTX5060A1000A POWER CONNS — V/PH/HZ 3 MIN BRCH CIR AMPACITY BR CIR i MAX (AMPS) PROT RTG I MIN (AMPS) COMPRESSOR NO USED -NO SPEEDS VOLTS/PH/HZ R L AMPS <•?• L R AMPS FACTORY INSTALLED START COMPONENTS ® INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA (IN ) - NO USED TYPE DRIVE -NO SPEEDS CFM @ 0 0 IN W G ® NO MOTORS -HP MOTOR SPEED RPM VOLTS/PH/HZ F L AMPS OUTDOOR COIL — TYPE ROWS-FPI FACE AREA (SO FT) TUBE SIZE (IN ) REFRIGERANT LBS — R-410A (O D UNIT) © FACTORY SUPPLIED LINE SIZE -IN OD GAS© LINE SIZE - IN O D LIQ @ 208/230/1/60 36 60 60 CLIMATUFR - SCROLL 1 - 1 208/230/1/60 264- 134 YES YES NO PROPELLER 266-1 DIRECT -1 4160 1 -1/3 850 200/230/1/60 280 SPINE FIN™ 1 -24 3079 3/8 11 LBS OOZ YES 1-1/8 3/8 CHARGING SPECIFICATION SUBCOOLING 9°F DIMENSIONS CRATED (IN ) WEIGHT SHIPPING (LBS ) NET (LBS ) H X W X D 57 4 x 35 1 x 38 7 354 304 A WARNING THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSES- SING ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANICAL EXPERIENCE ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDITION- ING PRODUCT MAY RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE THE MANUFACTURER OR SELLER CANNOT BE RESPONSIBLE FOR THE INTERPRETATION OF THIS INFORMATION, NOR CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE TUBING INFORMATION Tubing Sizes Suction Liquid 1-1/8" 3/8" 1-1/8" 3/8" 1-1/8" 3/8" 1-1/8" 3/8" 1-1/8" 3/8" Tubing lengths in excess of sixty (60) (eet sei Tubing Additional Length Refrigerant 20' 30' 40' 50' 60' e application software 4 02 12 oz 20 oz 28 oz 36 oz 1< Certified in accordance with the Air Source Unitary Air conditioner Equipment certification program which is based on ARI standard 210/240 '{•• Rated in accordance with ARI standard 270 ••"?• Calculated in accordance with Natl Elec Codes Use only HACR circuit breakers or fuses S Standard Air— Dry Coil— Outdoor •'>' This value approximate For more precise value see unit nameplate i: Max linear length 60 ft Max lift Suction 60 ft Max lift Liquid 60 ft For greater length consult refrigerant pip:ng software Pub No 3233120 {' denotes latent revision) :.z": This value shown for compressor RLA on the unit nameplate and on this specification sheet is used ID compute minimum branch circuit ampacity and max fuse size The value shown is the branch circuit selection current 3 No means no'tart components Yes means quick start kit components PTC means positive temperature coefficient starter A CAUTION HOT SURFACE' DO NOT TOUCH TOP OF COMPRESSOR. May cause minor to severe burning A CAUTION CONTAINS REFRIGERANT! SYSTEM CONTAINS OIL AND REFRIGERANT UNDER HIGH PRESSURE RECOVER REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING SYSTEM Failure to follow proper procedures can result in personal illness or injury or severe equipment damage A CAUTION RECONNECT ALL GROUNDING DEVICES ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING ELECTRICAL CURRENT ARE GROUNDED IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS, NUTS OR WASHERS USED TO COMPLETE A PATH TO GROUND ARE REMOVED FOR SERVICE, THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND PROPERLY FASTENED NOTICE Trano has a colicy of continuous product and product data improvement and it reserves the right to change design and specifications without notice © 2007 American Standard Inc Ml Rights Reserved PI 7/07 4TTX5060A1000A SCHEMATIC DIAGRAM 10 POWER SUPPLY PER UNIT NAMEPLAIE AND LOCAL CODES CA COOLING ANTICIPATOR LPCO LOW PRESSURE CUlOUT SW CBS COIL BOTTOM SENSOR MS COMPRESSOR MOTOR CONTACTOR CF FAN CAPACI10R OCA OUTDOOR ANTICIPATOR CN WIRL CONNEC70R CFT OUTDOOR FAN 1HEHVOSTAT CPR tOHPRESoOa OES OUTDOOR TENPFRAk'RE SENSOR CB RUN CAPACITOR GDI OUIDOOR ThtRMOSTAT CS STARTING CAPACITOR RH3 .RESISTANCE HEAT SWITCH CSR CAPACITOR SWITCHING RTLAY SC SWIlCHOVER VALVf SOLE.SOlO DrC DEFROST CONTRO. oM 5Y51EH ON OFF SWITCH F INDOOR FAN RELAY TDL DISCHARGE LINE THERMOSTAT HA KEATING ANTICIPATOR TNS TRANSFORMER HPCO HIGH PRESSURE CUTOUT SW TS HtAlING COOLING THERMOSTAT OL INTERNAL OVERLOAD PROTECTOR TSH HEATING "HESMGSfAT ACR JUC 3ECUFIER R Ofl SHUM RESISTOR A WARNING HAZARDOUS VOLlAGE1 DIG ONNECT ALL ELECTRIC POWER INC'UDING REMOTE DISCONNECTS BEFORE SERVICING FAILURE TO DISCONNECT PQWE3 BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJU.Rr OR DEATH' A CAUTION USE COPPER CONDUCTORS ONLY' UNIT TERMINALS ARE NOT DESiGNED TO ACCEPT OTHER TYPES OF CONDUCTORS JMLJRE TO BO SO MM CAUSE DAMAGE TO THE EQUIPMENT' :""^%TF0A»V l—o— ' 1 TYPICAL "I | 119 HANDLER 1 © TYPICAL IIE*T/COOL 1 THERMOSTAT n L ---- © --------- -© RIABLEN ^ COLOR OF WIRE PEED \BK/BL BLACK WIRE WITH 6LL-E MARKER *—COLOR OF MARKER BK BLACK OR ORANGE YL YELLOW BL BLUE RD RED GR GREEN 01? BROWN WH WHITE PR PURPLl ODT 3 IS NOT tS;D ADD JUMFEJ BEHEEN 12 J W3 AIR HANDLER USED ODT 0 MU3T BE MOUNTED REMOTE OF CONTHOL ; IN AN APPROVED «EATHER PHOOr ENCLOSC3E Z 03T A IS NOT USED ADD JUMPER BETWEEN II S »Z AIR HANDLER 3 0» VOLTAGE 111 V ! FIELD II1ING MUST BE 18 A»G MIN FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIF.NNES CALIT ION NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION NE CONVIENT PAS AUX INSTALLATIONS DE PLUS PE 150 V A LA TERSE SUBCOOLING CHARGING IN COOLING ABOVE 55 F OD AMBIENT Trane has always recommended installing Trane approved matched indoor and outdoor systems All Trane split systems are ARI rated with only TXV indoor systems The benefits of installing approved indoor and outdoor split systems are maximum efficiency, optimum performance and the best overall system reliability The following charging methods are therefore prescribed for systems with indoor TXVs 1 Subcooling (in the cooling mode) is the only recommended method of charging above 55°F ambient temperatures 2 For best results - the indoor temperature should be kept between 70°F to SOT Add system _ heat if needed Determine the Design Subcool Charging Temperature from the unit nameplate Locate this value in the appropriate column of the Sub- cooling Charging Table Locate your liquid line temperature in the left column of the table, and the intersecting liquid line pressure under your nameplate subcool value column Add refrigerant to raise the pressure to match the table, or remove refrigerant to lower the pressure Again, wait 20 minutes for the system conditions to stabilize before adjusting chaige again When system is correctly charged, you can refer to System Pressure Curves (on page 4) to verify typical performance At startup, or whenever charge is removed or added, the system must be operated for a minimum 20 min- utes to stabilize before accurate measurements can be made Measure Liquid Line Temperature and Refrigerant Pressure at service valves Determine total refrigerant line length, and height (lift) if indoor section is above the condenser SUBCOOL CHARGING TABLE CORRECTIONS FOR LINE LENGTH AND RISE "Z. LU < LL 0 t LUcr Add 10 psig to Subcool Charging Table Pressure Use Design Subcool Value from Table Q Subtract 10 psig from S C Table Pressure"] 10 20 25 30 40 60 TOTAL REFRIGERANT LINE LENGTH (FEET) 80 DWG. NO. 4TTX5060-SF-1 WIRING DIAGRAM LEGEND EOUIPMENT DIAGRAM ^^ MKE V } FACTOBT WISING III LINE V } FIELI) W'9IN° — X— FIELD INSTALLED FACTORY WIRING —*— GROUNC LPCO /~\ JJNC'ION' WIRE NUT OR CONNECTOR — )(— CAPACITOR "| p-- RELAY ( ONTACF I N 0 ] -tf- RELAY (ONTACT (N C ) <5~O IFtRMISTOR INTERNAL OVERLOAD PROTECTOR PRESSURE ACTUATED SWITCH TEMP ACTUATED SWITCH POL PLUG FEMALE HOUSING (MALE TERM } POL PLUG MALE HOUSING (FEMALE TERM ) V\AA RESIS10R OR HEATING ELEMENT MOTOR WINDING TERMINAL ENT -x-t z -X-^-J HO L i4— i_L TES a I i- — Cr~ L OOT 3 i-Jp- c LD$£\^cs x B (OPTIONAL) .^-^ 1 REMOTE l_ r > A (OPTIONAL) ,)[.i 1 11! \ \l jo j 1 £ LT" r t- \ 1 i 3 1*^1 KS S § ^ 1— j —I ^10 PO^ER SUPPLT PER -> UNIT NAMEPLATE AND _ _. _J 10CAL CODES [PRINTED FROM PI550I9POI REVOC'I R-410A REFRIGERANT CHARGING CHART LIQUID TEMP (T) 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 DESIGN SUBCOOLING (T) 8 9 10 11 12 13 14 LIQUID GAGE PRESSUFIE (PSI) 179 195 211 229 247 267 287 309 331 355 381 407 435 464 495 182 198 215 232 251 271 291 313 336 360 386 413 441 470 501 185 201 218 236 255 275 296 318 341 365 391 418 446 476 507 188 204 222 240 259 279 300 322 346 370 396 424 452 482 514 Refer to Service Facts or Installer's Guide for charging method 191 208 225 243 263 283 304 327 351 376 402 429 458 488 520 195 211 229 247 267 287 309 331 355 381 407 435 464 495 527 198 215 232 251 271 291 313 336 360 386 413 441 470 501 533 From Dwg D154557P01 Rev 2 PRESSURE CURVES FOR 4TTX5060A1OOOA 4TXCD064BC3 Cooling with Thermal Expansion Valve „ 500 — INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71 67 63 AND 59 DEC F I (2) 40 50 60 70 80 90 100 110 120 OUTDOOR TEMPERATURE (Degree F) INDOOR ENTERING WET BULB CURVES TOP TO BOTTOM 71 67 63 AND 59 DEG F UJ EC 3 CO CO UJrra. 50 60 70 80 90 100 110 120 OUTDOOR TEMPERATURE (Degree F) COOLING PERFORMANCE CAN BE CHECKED WHEN THE OUTDOOR TEMP IS ABOVE 65 DEG F TO CHECK COOLING PERFORMANCE SELECT THE PROPER INDOOR CFM ALLOW PRESSURES TO STABI' IZf MEASURE INDOOR WET BULB TEMPERATURE OUTDOOR TITMPERATURE LIQUID AND SUCTION PRESSURES ON THE PLOTS LOCATE OUTDOOR TEMPERATURE (1) LOCATE INDOOR WET BULB (21 FIND INTEHSCCTION OF OD TEMP MD VI B 13) READ LIQUID (4) OH SUCTION (5) PRESSURE IN LEF r COLUMN EXAMPLE (I) OUTDOOR TEMP 82 F (2) INDOOR WET BULB 67 F (3) AT INTERSECTION (4) LIQUID PRESSURE 0 1700 CFM IS 315 PSIG (6) SUCTION PRESSURE & 1700 CFM IS 137 PSIG INTERCONNECTING LINES GAS 11/2 O D LIQUID 3/8"OD ACTUAL LIQUID PRESSURE SHOULD BE +/ 10 PSI OF CHART SUCTION PRESSURE SHOULD BE W 3 PSIG OF CHART DWG NO 4TTX5060A1 REFRIGERANT CIRCUIT FIELD IKSHLLED INTER CONNECTING TU8ING OUTDOOR SECTION BEFBIGEBATION FIO» COOLING REFRIGERATION CYCLE PRINTED FROM D155234 REV 00 ARTICLE 310: Conductors for General Wiring NEC Table 310.16 Table 310 16 Allowable Ampacities of Insulated Conductors Rated 0 Through 2000 Volts, 60°C Through 90°C (140°F Through 194°F) Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried) Based on Ambient Temperature of 30°C (86°F) Temperature Rating of Conductor or kcmil 18 .'16V 14* 12*?. 10*/&y or 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 * 400 ; : 500 600 700 ' •;: 750 -'•'- 800 900 1000 1250 1500 1750 2600 :; 60°C (140°F) Types TW UF 75°C (167°F) Types RHW THHW THW THWN XHHW USE ZW 90°C (194°F) Types TBS SA SIS FEP FEPB Ml RHH RHW 2 THHN THHW THW 2 THWN 2 USE 2 XHH XHHW XHHW-2 ZW2 COPPER _ •:•••" - ""°20 25 3fLQcp 55 70 85 95 110 1251-: 145 165-f;v 195 '• 215 7 240 260 280 rX320 355 385 400 ':410 '435 ;:455 495 520 545 560 _ '"-' '::"::":' 20 25 35 (50) 65 85 100 115 130 150 175 200 230 255 285 310 335 380 420 - 460 475 49'0."!'-\ 520 . 545 590 625" " 650 ----.-ggg- 14 18 25 30 " 95 110 130 150 170 195 225 260 290 320 350 380 430 475 - 520 535 555 585 615 665 705 735 750 60°C (HOT) Types TW UF 75°C (167°F) Types RHW THHW THW THWN XHHW USE 90°C (194°F) Types TBS SA SIS THHN THHW THW 2 THWN 2 RHH RHW 2 USE 2 XHH XHHW XHHW-2 ZW2 ALUMINUM OR COPPER-CLAD ALUMINUM _ - - 20 25 30 40 55 s 65 75 85 ioo ' " T15 130 150 ~'~T70 ",' 190 210 225" 260 285 310 320 330 355 375:: 405" 435, 455 470 _ ::;.|l!!- - "';i":.... 20 30 •i: 40 50 ;: 65 75 90 100 120 135 155 180 205 ; 230 250 270 310 340 : 375?:? 385 395 v- " 425 445 iSi?- 485 520 / '"•" 545 •:566-v';.-:v _ - - 25 35 "45 60 75 85 100 115 135 150 175 205 ; 230; 255 280 ., 305 350 385 '••'" 420 435 P. 450 480 '.:;r:.- 500 545 :••• 585 615 :;" 630 or kcmil _ - _' 12* 10* 8 6 4 ' 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 800 900 : 1000 1250 1500 1750 2000 CORRECTION FACTORS Ambient Temp (•C) 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60 61-70 : 71-80 ; For ambient temperatures other than 30°C (86°F) multiply the allowable ampacities shown above by the appropriate factor shown below 1 08 100 091 082 071 058 041 1 05 1 00 094 , 088 ~ 082 075 " , 067 058 " 033 1 04 1 00 096 091 087 082 076 071 058 041 1 08 1 00 091 082 071 0 58 041 1 05'.•'i.'bo. :: 094 088 08? 075 067 058 033 1 04 v;7"~f o~0 """. 0 96 ,;-. fjgf 087 082 " , 076 071 "• 058 041 Ambient Temp (°F) 70-77 78-86 •'..-! 87-95 96-104: 105-113 114-122 123-131 132-140 : 141-158 159-176 •: * Small Condutors Unless specifically permitted in 240 4(E) through (G) the overcurrent protection shall not exceed 15 amperes for 14 AWG 20 amperes for 12 AWG and 30 amperes for 10 AWG copper or 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum and copper clad aluminum after any correction factors for ambient temperature and number of conductors have been applied rWlfflQK Will t OWE aWJW 208 All litifu suhjcci to cfntngL' nit hum 1-800-HOUWIRE 200-1 I'm/mi Cal ACORH CERTIFICATE OF LIABILITY INSURANCE 77™oo8¥) PRODUCER (800)524-7024 FAX (800)524-4013 Automatic Data Processing Insurance Agency, Inc 1 AOP Boulevard Roseland, N3 07068 INSURED Major League Heating & Air Conditioning, Inc. 1316 North Mel rose Drive Suite C Vista, CA 92083 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORDING COVERAGE INSURER A. Employers Compensation Ins. Co INSURER B INSURER C INSURER D INSURER E NAIC# COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE COR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPEC T TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR LTR A UDD'L NSRE TYPE OF INSURANCE GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY | CLAIMS MADE I" [ OCCUR GEM. AGGREGATE LIMIT APPLIES PER—] POUCY n^f r~i">c AU1 GAF EXC "1 rOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OWNED AUTOS (AGE LIABILITY ANY AUTO ESS/UMBRELLA LIABILITY OCCUR | ] CLAIMS MADE DEDUCTIBLE RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? If yes describe under SPECIAL PROVISIONS below OTHER POLICY NUMBER ADP030259207 POLICY EFFECTIVE DATE IMM/DD/YY) 07/24/2008 POLICY EXPIRATION DATE IMM/DD/YY) 07/24/2009 LIMITS EACH OCCURRENCE DAMAGf IO RENTED PRFMIKFK If it ncniranm) MED EXP (Any one person) PERSONAL & ADV INJURY GENERAL AGGREGATE PRODUCTS - COMP/OP AGG COMBINED SINGLE LIMIT (Ea accident) BODILY INJURY (Per person) BODILY INJURY (Per accident) PROPERTY DAMAGE (Per accident) AUTO ONLY - EA ACCIDENT OTHER THAN EA ACC AUTO ONLY AGG EACH OCCURRENCE AGGREGATE 1 WCSTATU 1 lOTH- 1 TORY LIMITS 1 1 FR E L EACH ACCIDENT E L DISEASE - EA EMPLOYEE E L DISEASE - POLICY LIMIT t $ s *$ s $ $ $ s $ $ $ $ $ $ 1 $ s 1,000,000 $ 1,000,000 $ 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT/ SPECIAL PROVISIONS License # : 807897 CERTIFICATE HOLDER CANCELLAYlON ****** INSURED 'S COPY ****** SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL 'SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THI. INSURER, ITS AGENTS OR REPRESENTATIVES AUTHORIZED REPRESENTATIVE ~~^2-^ ~ Rudy Pena/MOSCJ -^^f- -- \CORD 25 (2001/08)©ACORD CORPORATION 1988