HomeMy WebLinkAbout2165 CORTE ACEBO; ; CB982162; Permit09/2/2/9.3 09 Page' i of Job Address Permit Type BUILDING PERMIT 19 1 2165 CORTE ACEBO Suite: SINGLE FAMILY DWLNG - DETACHED Permit No Project No Development No Parcel No 255-260-08-00 Valuation- 189,526 Occupancy Group Description: Lot# Referenced• 135 Construction Type CT88-03 Status PLAN 2,PHS 7,2114+625 GAR+91 Applied- DECK+98 SF PORCH,VILLAGE Q,LA COSTA,KAUF Apr/Issue Entered By Appl/Ownr : KAUFMAN & BROAD 619 259-6000 12626 HIGH BLUFF DR STE 400 SAN DIEGO CA 92130 Plan Check Numbers > ORIG 972911 PCK 981766 *** Fees Required *** *** Fees Collected & Credits CB982162 A9802852 DEV89110 VN ISSUED 05/22/98 09/22/98 RMA Fees 9,051 79 Adjustments. 00 Total Fees 9,051 79 Fee description 1333 09/22/98 0001 01 02 Total Credits. C-PftlfT 9051-79 Total Payments 00 Balance Due: 9,051 79 Units Fee/Unit Ext fee Data Number of Bedrooms . . . > Number of Bathrooms ...... > Building Permit Plan Check Strong Motion Fee Enter Plan Check Discount Amt > •. Enter "Y" to Autocalc P.F.F. •';>' Enter "Y" to Autocalc T.I.F.. > Payoff Fee for CFD > Enter LFM Fee ( Zones =6 , 11 , 12 ) ;> Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Building Sewer .' > Each Install/Repair Water Line > Each Water Heater and/or Vent > Gas Piping System > Each Vacuum Breaker > Enter "Y" for Electric Issue Fee > Single Phase Per AMP > Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > Each Install Fireplace > Each Exhaust Fan > Each Install/Reloc Vent > 2 50 .;; 49:. 00 2965 79 : ' -3 10. 00 ' '•".. '"••.• 12 - ':. . 1 -.•"• .. ' •-.; 1 ..•"• : • . ' '. . •: I"''.. 1 2 125 2 1 3 2 !';, -1. - " 7. 15. 7. 7 7 7 . 9 6. 6 4. . . " v.. 00, 00 00 00 00 00 00 25 00 50 50 50 4 2 . 936. 608 19. -49 3449 550 2965 310. 20 84 15 7. 7 7 14 10 31 15 18. 6 19 9 00 50 00 00 00 00 00 00 79 00 00 00 00 00 00 00 00 00 25 00 00 50 50 00 Y Y Y Y Y FINAL 1 CLEARANCE, CITY OF CARLSBAD 2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1161 OVAl DA-t, City of Carlsbad Inspection Request For 5/25/99 Permit# CB982162 Title PLAN 2,PHS 7,2114+625 GAR+91 Description DECK+98 SF PORCH.VILLAGE Q,LA COSTA.KAUF Inspector Assignment NF 2165 CORTEACEBO Lot 135 Type SFD Sub Type Job Address Suite Location APPLICANT KAUFMAN & BROAD Owner ACACIA CREDIT FUND 5-A L L C Remarks Phone 760-741-7363 Inspector /UP Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By MIKE Entered By CHRISTINE Act Comments Date 5/21/99 5/18/99 4/20/99 4/19/99 4/19/99 4/19/99 4/14/99 4/15/99 4/13/99 3/15/99 3/15/99 3/15/99 2/17/99 2/17/99 2/17/99 2/11/99 2/11/99 2/1/99 Inspection History Description Act Insp Comments 89 Final Combo 39 Final Electrical 22 Sewer/Water Service 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 23 Gas/Test/Repairs 16 Insulation 16 Insulation 84 Rough Combo 13 Shear Panels/HD's 15Roof/Reroof 82 Drywall/Ext Lath/Gas Test 11 Ftg/Foundation/Piers 21 Underground/Under Floor 31 Underground/Conduit-Wiring 21 Underground/Under Floor 22 Sewer/Water Service 89 Final Combo CO NF AP NF AP NF CO NF CO NF AP NF AP NF CA NF APPDON4/14 AP NF CO NF AP NF WC NF AP NF AP NF AP NF AP NF AP NF WC NF City of Carlsbad Final Building Inspection FEB- I Dept Building Engineering Planning CMWD St Lite Fire Plan Check # Permit* Project Name Address Contact Person Sewer Dist CB982162 PLAN 2,PHS 7,2114+625 GAR+91 DECK+98 SF PORCH.VILLAGE Q,LA COSTA.KAUF 2165CORTEACEBO N/A Phone LC Water Dist O Lot Date Permit Type Sub Type 135 2/1/99 SFD Inspected By Inspected By Inspected By Date Inspected Date Inspected Date Inspected Approved * Approved Approved Disapproved Disapproved Disapproved Comments City of Carlsbad Final Building Inspection •jgk^TJI^CaJB Dept. Building Engineering Planning Plan Check # Permit # CB982162 Project Name PLAN 2.PHS 7,21 14+625 GAR+91 DECK+98 SF PORCH.VILLAGE Q Address 2165CORTE ACEBO Contact Person N/A Phone Sewer Dist LC Water Dist O Inspected Date Bv r\ 4—^ Inspected Inspected Date Bv Inspected Inspected Date Bv Inspected Comments CMWD StLite <Fire> Date 2/1/99 Permit Type SFD Sub Type ,LA COSTA.KAUF Lot 135 ^~7 *//*? *l Approved ^^"Disapproved Approved Disapproved Approved Disapproved City of Carlsbad Final Building Inspection Dept- Building Engineering Planning CMWD 'St'tit? Fire Plan Check* Permit* Project Name Address Contact Person Sewer Dist Inspected , Bv / Inspected Bv Inspected Bv CB982162 PLAN 2.PHS 7,2114+625 GAR+91 DECK+98 SF PORCH.VILLAGE Q 2165CORTEACEBO N/A Phone LC Water Dist O i Date J & Inspected Date Inspected Date Inspected Date Permit Type Sub Type ,LA COSTA.KAUF Lot 135 2- / 21/7 i Approved L--^^ Approved Approved 2/1/99 SFD Disapproved Disapproved Disapproved Comments SOUTHERN CALIFORNIA SOIL & TESTING, INC. 6280 Riverdale Street, P O Box 600627 , San Diego, CA 92160, (619) 280-4321 FIELD INSPECTION REPORT PROJECT TJTI.E PROJECT LOCATION ARCHITECT GEN CONTRACTOR Westfield/Village Q, Lot 135 2165CorteAcebo Kaufman & Broad Kaufman & Broad SCSATFILENO PERMIT NO ENGINEER SUBCONTRACTOR 9812071 IRNO 98-2162 TRACT J L Davidson Concrete Concepts 25(Pg1 of 1) 88-03-2 2/16/99 G Wolfram #259 2/20/99 G Wolfram #259 POST TENSION CONCRETE PT ASTM A416, YS, 7 Wire, 270ksi Concrete Superior Ready Mix #CC5 F'c = 2500psi Time Arrived 1545 Time Departed 1630 I inspected post-tension cables, reinforcing steel and footings for the house foundations on Lot 135, plan 2 Hold downs are not in place at this time Time Arrived 0700 Time Departed 1230 I re-inspected foundation for hold downs All hold downs are in place and the foundation is acceptable for concrete placement I provided continuous inspection during the placement of concrete for the house foundation Consolidation of the concrete was done by mechanical vibrator and tamper One set of three concrete test cylinders and a slump test were taken from the concrete placed into the house foundation slab Slump test = 4 V*" I hereby certify that I have inspected the above reported work Unless noted otherwise, the work is to the best of my knowledge in compliance with the approved plans, specifications and applicable sections of the governing building laws DISTRIBUTION (2) Kaufman & Broad, Attn Mike Cravens (1) City of Carlsbad REVIEWED BY George A Gavit, R C E # 56564 SOUTHERN CALIFORNIA SOIL AND TESTING, iMiCElVEB 6280 RIVERDALE STREET, P O Box 600627, SAN Dmco, CA 92160 (619) 280-4321 APR t - 1999 Concrete Compressive Strength Test Report ENGINEERING File Number Project Title Project Location Architect Engineer Contractor 9812071 Westfiled Village (Q) 21 65 Corte Acebo Kaufman & Broad J L Davidson Kaufman & Broad/Concrete Concepts DEPARTMENT Permit No 982162 Plan File No Location In Structure Material Supplier Mix Designation Admixture(s) Time In Mixer (Minutes) Truck Number Samples Fabricated By Lot #135 - house foundation slab Superior Ready Mix CC-5 Pozz 70 Slump, Inches 4-1/4 341 Ticket Number 120883 GAW Samples Tested By GG CC Temp Air Temp Air Content 62° Laboratory Number Mark 135 Date Made Date Received Date Tested Diameter, Inches Area, Square Inches Maximum Load, Pounds Compressive Strength, psi Age Tested, Days Required 28 Day Strength, psi Fracture Type 8322 02-20-99 02-21-99 03-02-99 600 2827 85,500 3,020 10 2,500 8323 03-20-99 114,500 4,050 28 8324 03-20-99 112,750 3,990 28 Specimen Compressive strength testing were performed by this agency in accordance with the ASTM C39-96 standard This agency makes no other warranties express or implied Legend Fracture Type - Cone =C, Cone and Split =CS, Cone and Shear =CSH, Shear = S, Columnar = CL Distribution (2) Kaufman & Broad (1) City of Carlsbad (1) Superior Ready Mix Reviewed By George Gavit, RCE #56564 02-20 doc 3/22/99 SOUTHERN CALIFORNIA SOIL & TESTING, INC. 6280 RIVERDALE STREET, PO BOX 600627, SAN DIEGO, C A 92160-0627, Phone (619) 280-4321, FAX (619) 280-4717 FIELD INSPECTION REPORT FOR* D REINFORCED CONCRETE D REINFORCED MASONRY Q WELDING Q FIREPROOFING JStfT CONCRETE D EPOXY ANCHORS DH S BOLTING D PROJECT TITLE /jJ/f^~T"7^'//ii/A ~V I 3 S~1 SCS&T FILE No ^ & ^s^ C$~7 / PROJECT LOCATION O / / <T* /?, _,_, /j />s-- /-> ^ i PERMIT No£2 C 9 / / . ~v PLAN FILE Norv / (<' J i ft f** I r~ /~f v- 1~ ' > (\ / u p* / »£••' "*"-. ARCHITECT ix< A r '-j ,. ENGINEER i , >x - ,-. GENERAL CONTRACTOR j /.. f- ^ , A -, . .-> SUB CONTRACTOR X?, f/^r??/"A/;7~f' MATERIAL CLASSIFICATION is,——. At-~i A(J/^ !/ ' "/' ^T-.^r'jT2* ( /- \ ^ ~\A-\ r\M t v^? , /^ /co ( // c- -*' /c ^r S / • DATE 1-//6/& ' / 1 hereby certify tt work Unless no the best of my knc plans, specificat governing buildm DESCRIPTION OF WORK INSPECTED 1 /O <\?~}/ZLf 7~7^0 /f)/'/ / "" ~/~/c'.J\J*£lf'a.s) t /^d&/ f^- C £ <?-/AJf~Qf?Ci. CTX^ / x?/.)'\ /L-Or^'7~'/^J A/ T >-cj&? /j'<r //{}()<t/z /- /o o r>u }C^r/7 '('^ / ' ^ "" " ' S/6/sJ (7)nt<j*Jt /Qs?* A>/>~ ,,> S)das<* ,4 r~ 7>//rf tfT7/Sf7 77/^*J ~T?/4T tt<.J^a.A77c»M ^ /)/)*,*>< P f -v— 4^/Cf. (^ IT\ ~7~I/\ii( f /~r*\ i'? i^/"}/l-J {"/<?£• /(Z f) ISlf/Z-tVlfAjl 1 , •• ' t/ ^ " •- •• " (Qfi'^'&t^r-f f-l ' /-/ ^('}^f-K^\ l^\ S f ) / ^-f ) ^ ' -^^ / <•? "1 X?/* ' •A'lat 1 have inspected the above reported / - ////'' ^//// /J^ /^J ^ (. * ~' -" ~" '"^ <" ted otherwise, the work inspected is to i ^ ----«> _^ •-/. A^&-r £-*— ' -f- Ci )' } (..•/•^" ' / Sfr / \ ~ \ 7 >wledge in compliance with the approved ^ -f / INSPECTORS SIGNATURE REGISTRATION No ions and applicable sections of the A 1 / — / ~ — — 4 / / , /*o ^"> g laws ! y \J"^O / / <V ^X? ' 6<? •• ? <i' / /('••>/?/ SUPERINTENDANTS SIGNATURE ' -DATE ' ' t( ' GEOCON INCORPORATED GEOTECHNICAL CONSULTANTS 6960 FLANDERS DRIVE • SAN DIEGO, CALIFORNIA 92121-2974 • TEL (619) 556-69OO • FAX (619) 558-6159 FOUNDATION OBSERVATION REPORT hlolfA " VA "*5<^ & - JDcSrflcMi PROJECT NOPROJECT NAME LOCATION £***DATE FOUNDATION LOCATION (if not enhre building)£07" PLAN FILE NO FOUNDATION TYPE D CONVENTIONAL tf POST TENSIONED PERMIT NOS D ADDITIONAL OBSERVATION REQUIRED SJ SUBSTANTIAL CONFORMANCE • PURPOSE OF OBSERVATION V& Verify soil conditions exposed are similar to those anticipated SI Verify footing excavations extend to minimum depth recommended in soil report D Verify foundation reinforcement complies with minimum recommended in soil report D Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report K[ Verify footings have been extended to an appropriate bearing strata D Other APPLICABLE SOIL REPORT TITLE DATF • SOIL REPORT RECOMMENDATIONS BASED ON ^f Expansion Condition $f VERY LOW D LOW D MEDIUM |5f Fill Renmetry f~til £. 3O D HIGH D VERY HIGH D Other MINIMUM FOUNDATION RECOMMENDATIONS Footing Depth D 12 Inches D 18 Inches D 24 Inches OTHER f**• or **Footing Reinforcement DNo4T&B D2-No4T&B D 2-No 5T&B jj& Post-Tensioned OTHER __' Interior Slab Reinforcement D 6x6-10/10 D 6x6-6/6 D No 3@24lnches D No 3@18lnches flj] Post-Tensioned Slab Bedding Material and Thickness J^ <J^^. Vapor Barrier j 1'' j-, *Foundation Width 'J* O^ • OBSERVATIONS <$ Substantial conformance with Soil Reports (see "Purpose of Observation") D Substantial conformance with Foundation Plans Identify . D Other COMMENTS i IS ASSUMED THAT ALL FOOTING EXCAVATIONS WILL K CLEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOIL MOISTURE CONTENT WILL BE MAINTAINED K+ FIELD COPIES TO REPRESENTATIVE