HomeMy WebLinkAbout2171 AVENIDA TORONJA; ; CB091906; Permit12-03-2009
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Electrical Permit Permit No: CB091906
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC#:
Project Title:
2171 AVENIDA TORONJA CBAD
ELEC
2552616400 Lot#:
SCARSKI: ROOF MOUNT PV SYSTEM
Status: ISSUED
Applied: 11/16/2009
Entered By: JMA
Plan Approved: 12/03/2009
Issued: 12/03/2009
Inspect Area:
Applicant:
NATURAL ENERGY
TED MOUNT
147'S VINEWOOD ST 92029
760 743-6400
Owner:
SCARSKI KEVIN L&CAROLYN A
2171 AVENIDA TORONJA
CARLSBAD CA 92009
Electric Issue Fee
Single Phase per AMP
Three Phase per AMP
Three Phase 480 Per AMP
Remodel/Alteration per AMP
Remodel Fee
Temporary Service Fee
Test Meter Fee
Other Electrical Fees
Additional Fees
0
0
0
0
$10.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$110.00
$0.00
TOTAL PERMIT FEES $120.00
Total Fees:$120.00 Total Payments To Date:$60.00 Balance Due:$60.00
Inspector:
FINAL APPROVAL
Date: .Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other requited information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
CITY OF
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 / 2718 / 2719
Fax: 760-602-8558
Plan Check No.
Est Value
Plan Ck. Deposit
JOB ADDRESS
2.111 LCVLOK>tiA
PHASE
SUITE#/SPACE#/UNIT#
CT/PROJECT#
DESCRIPTION OF WORK: IncJudeSoMra Feet of Affected Ana(»)
# # OF UNITS f BEDROOMS * BATHROOMS TENANT BUSINESS NAME OONSTR. TYPE OCC. GROUP
IIPTJON
3*
EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE
YESD #NOD
AIR CONDITIONING
YES D NO Q
FIRE SPRINKLERS
YES a NO D
CONTA'ACT NAME W DMwent Fom•JosspM \JpftttFom Appllcmnt)APPLICANT NAME-
ADDRESS x^or.ADDRESS
CITY STATE ZIP CITY STATE ZIP
PHONE - SOi -FAX PHONE FAX
OCX^ P
EMAIL
PROPERTY OWNER
*
s CONTRACTORBUS.
. ".N*rc
NAME
ADDRESS ADDRESS
STATE ZIP
9" 100*7
CITY STATE ZIP
PHONE FAX PHONE FAX
EMAIL EMAIL
ARCH/DESIGNER NAME & ADDRESS CITY BUS. UC.#
12E.3t.8l
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars $500)).
WORKERS COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of Vie following declarations:
O I have and wiH maintain a certificate of consent to teff-kwun for workers' compensation as provided by Section 3700 of the Labor Code, for the pertinnance of the wort for which this pemiit is issued.
O-Titave and will maintain workers' compensation, as required by Section 3700 of the Labor &xte, for the pe*miatice of Ihe wort Ibrwhirt this pern* is issued. My wo^
number are: Insurance Co. gyfyrrgT "fixJ<b Policy No. Q&L *^"ri 5 Expiration Date ) f I I1O
This section need not be completed if the peimit is fororo hundred dollars ($100) or toss.
C3 Certificate of Exemption: l<an%tnatmlh»3*r!omiaice>Mhewo*fwwn^
California. WARNING: Failure to secure wftkirt' compensiriton coverage Is unlawful, and shall subject an employer to criminal penalties and dvH fines up to one hundred thousand dollars (&100,000), hi
addition to the cost of compensation, dam>0fs as providedj&r m Section 3706 of the Labor code, mtarest and attorney's fees.
CONTRACTOR SIGNATURE
O W N E R- B U I L O Z R DECLARATION
DATE
/ hereby sffrm thai I am exempt from Contactor's Ucense Lur for the fefarfng reason:
O I, as owner of the properly or my employees wi«i wages as their sole compensation, will do tte work and the structure Is iwtintenoW or olfen^hr sale (Sec. 70<4, Business and F^
License Law does not apply to an owner of property who builds or improves Irweon, ar«lwr« does such wortchimjelf or ttvough his own emptoy»«, provided Ihrt
sale. K, however, the buNoIng or iniprovenwrt is sold wihin one year of com
O I, as owner of the property, am exclusively contracting with licensed cortradcre to construct the p(oject (Sec. 7W, Business ara) Prctea not apply to an owner of
property who builds or improves thereon, and contracts for such projects wimcontracton|s) licensed pursuant to the Confractof's License Law).
O I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for coretnx^cif the proposed propenVimprovament. OYes O No
2.1 (have / have not) signed an application for a building, permit for the proposed work.
3.1 have contracted w* the following person (firm) to provide the proposed consfnK*e>n (irdude name address / phone / con*actc«'kcenM number
4.1 plan to provide portions (if the work, but I have hinxl tne following penxm
5.1 win provide some of the work, but I have contracted (hired) the IWIcwing persons to pnwde the wort indicated fiixdude name / add^
^PROPERTY OWNER SIGNATURE OAGENT DATE
FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
It lheappfc»nt or Mure buMng occupant rec^ired to tubmH»
Presley-Tarn* Hazardous Subetana Account Act? OYn QNo
te the applicant or Mure buMng occupant required to attain a permit from the * pollulion contra! district or air qurity management dltlrict?
to the teflty to be constructed wWtin 1,000 bet of tw outar boundwy of a school *e?
EMERGENCY SERVICES AND THE MR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a constrochon lending agency for me performance of the work 9ns p«m««Bsued (Sec. 3097 (i)CMlCo«l»)
Lender's Name Lender's Address
lcerty«i*lhavenadtheapplcidM«idflatethatthe
rortaied proffer inspection r^^
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAJNST SAD CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT,
deep are! derrottai or ronstructionc* struct^
Iheproswora of Ihe Code shall expire by liriafon are) beconnenul art
aulwr^ by su<*rjem* is suspended or abarcfc^ at arty Im
DATE
AGAINST All LIABUTIES,
OSHA: An OSHA permit is mquM fcr
Jf^MVUCMHTS SIGMA1
CITY OF
CARLSBAD
STORM WATER
COMPLIANCE
EXEMPTION
B-24
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
I am applying to the City of Carlsbad for the following type(s) of construction permit:
a Building Permit Q Right-of-Way Permit
rMy project is categorically EXEMPT from
the requirement to prepare a storm water
pollution prevention plan (SWPPP) because it
only requires issuance of one or more of the
following permit types:
Fire Alarm
Fixed Systems
Mechanical
Mobile Home
Plumbing
Re-Roofing
Sign
Spa-Factory
Sprinkler
Water Discharge
Project Storm Water Threat Assessment Criteria*
No Threat Assessment Criteria
Q My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because
it meets trie "no threat' assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier
Level. My project does not meet any of the High, Moderate or Low Threat criteria described below.
Tierl • Low Threat Assessment Criteria
Q My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project
meets one or more of the following criteria:
• Results in some soil disturbance; and/or
• Includes outdoor construction activities (such as roofing, saw cutting, equipment washing, material stockpiling, vehicle fueling, waste
stockpiling).
Tier 2 • Moderate Threat Assessment Criteria
Q My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria:
• Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or,
• Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria:
• Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or
• Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or
• Disturbed area is located along or within 30 feet of a storm drain inlet an open drainage channel or watercourse, and/or
• Construction will be initiated during the rainy season or wiU extend into the rainy season (Oct. 1 through April 30).
Tier 3 • Significant Threat Assessment Criteria
LI My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or
Q My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, refueling and maintenance areas: or,
Q My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant
potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge^).
f certify to the best of my knowledge that the above
checked statements an true and correct I understand
and acknowledge that even though this project does
not require preparation of a construction SWPP, I must
still adhere to, and at all times during construction
activities for the permit typefs) check above comply
with the storm water best management practices
pursuant to Title 15 of the Carlsbad Municipal Code
and to City Standards.
The City Engineer may authorize minor variances from (he Storm
Water Threat Assessment Criteria in special circumstances where it
can be shown that a lesser or higher Construction SWPPP Tier Level is
warranted.
Project Address:
2I7I
Assessor Parcel No.
4 o
Owner/Owner's Authorized
Agent Signature:
By:
Tito:
Dale:
II 1 IL
Project 10;
B-24 Page 1 of 1 Rev.03/09
City of Carlsbad Bldg Inspection Request
For: 12/18/2009
Permit* CB091906
Title: SCARSKI: ROOF MOUNT PV SYSTEM
Description:
Inspector Assignment:C
2171 AVENIDA TORON JA
Lot: 0
Type: ELEC Sub Type:
Job Address:
Suite:
Location:
APPLICANT NATURAL ENERGY
Owner: SCARSKI KEVIN L&CAROLYN A
Remarks:
Phone: 7608024463
Inspector:
Total Time:
CD Description
39 Final Electrical
Comments
Requested By: JOSEPH JAMES
Entered By: CHRISTINE
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description Act Insp Comments
EsGil Corporation
In <PartnersKip witk government for Quitting Safety
DATE: 12/02/O9 a AEEU£ANT
JURIS.
JURISDICTION: Carlsbad b-PfaWREVlEWER
Q FILE
PLAN CHECK NO.: 09-19O6 SET: II
PROJECT ADDRESS: 2171 Avenida Toronja
PROJECT NAME: Scarski 5,OOO Watt Solar Photovoltaic
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil i
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
1X1 REMARKS: The applicant to revise remaining single line diagrams to match approved returned
set: "100 ampere main" on the existing service.
By: Eric Jensen Enclosures:
EsGil Corporation
D GA D EJ D PC 12/02/phone
9320 Chesapeake Drive, Suite 208 *• San Diego, California 92123 * (858)560-1468 *• Fax (858) 560-1576
EsGil Corporation
In Partnership with government for <BuiCifing Safety
DATE: 11/24/O9 OAPPLICANT
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 09-1906 SET: I
PROJECT ADDRESS: 2171 Avenida Toronja
PROJECT NAME: Scarski 5,OOO Watt Solar Photovoltaic
I I The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes ::.
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed cheek list
and should be corrected and resubmitted for a complete recheck. . ' • :
XI The check list transmitted herewith is for your information. The plans are being held at Esgi.11
Corporation until corrected plans are submitted for recheck. :
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. .
I | The applicant's copy of the check list has been sent to: : ,
Esgil Corporation staff did not advise the applicant that the plan check has been completed. ::
IXI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Natural Energy Telephone #: 760 743-6400
Date contacted: dfofb^tyfefc) Fax #: 760 743-0871
Mail Telephone Fax ^ In Person
1 REMARKS:
By: Eric Jensen Enclosures:
EsGil Corporation
D GA D EJ D PC 11/19
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 *• Fax (858) 560-1576
Carlsbad O9-19O6
11/24/09
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad PLAN CHECK NO.: 09-1906
PROJECT ADDRESS: 2171 Avenida Toronja
DATE PLAN RECEIVED BY DATE REVIEW COMPLETED:
ESGIL CORPORATION: 11/19 11/24/09
REVIEWED BY: Eric Jensen : : \
FOREWORD (PLEASE READ): ,
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code-and state
laws regulating energy conservation, noise attenuation and disabled access.-. This, plan review
is based on regulations enforced by the Building Department. You may have .other.corrections
based on laws and: ordinances enforced by the Planning Department, Engineering Department
or other departments. : ;-
The following items, listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• Please make all corrections and submit two new complete sets of prints to: -. <
ESGIL CORPORATION. ;
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that afa-not a result of
•'. ' corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
; Q Yes Q No .
Carlsbad O9-1906
11/24/O9
ELECTRICAL and ENERGY COMMENTS
PLAN REVIEWER: Eric Jensen
ELECTRICAL (2005 NATIONAL ELECTRICAL CODE)
1. The total overcurrent device rating may not exceed 120% of the rating of the service.
The submitted design describes a 125 ampere meter/main with a 30 ampere 2 pole
circuit breaker added for a total of 155 amperes where a maximum 150 amperes is
allowed. NEC 690.64 (B)
. • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
.Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the.
plan review for your project. If you have any questions regarding these plan review items,
please contact Eric Jensen at Esgil Corporation. Thank you.
Carlsbad O9-1906
11/24/09
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 09-1906
PREPARED BY: Eric Jensen DATE: 11/24/09
BUILDING ADDRESS: 2171 Avenida Toronja
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
BUILDING
PORTION
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction C'ode
AREA II Valuation
(Sq.Ft.) Multiplier
;:-....';.- ••'.'••
cti" •
; ' ' * •
RIHn Pprmit1 FPP hv Orrlinanrp I ^
'"'•: • .'. •'. i ' '•
By Ordinance
Reg.
Mod.
( • '• .-
i ' *' - •
V""' '' ' ;
VALUE ($)
;>.-_.. - . . -• :. •
< ••," * -' '•*• " . ' "... ..-'" '
• .
Plan Check Fee by Ordinance . .
s Type of Review: : • D Complete Review.
Repetitive Fee
Repeats
D Other
i—i Hourly
EsGil Fee
$107.50
$86.00
Structural Only
$86.00
$86.00
Based on hourly rate
Comments: 1 hour plan review.
Sheet 1 of 1
macvalue.doc +
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB DATE nlnh
ADDRESS
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR
« $10.000.00)
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER
ENGINEER
DATE
DATE ll/nh
Docs/Mltrorms/Plannino Enginctrlng Approvals
jui ua
r.NATURAL £N€RCY
Natural Energy USA Inc
147SvlnewoodS1
Escondldo, Ca 92029
760-745-4400 office
740-743-0871 tax
tvwMr.nalurotenargyusa.cofn
FAX
To:CITY OF SAN DIEGO From: TED MOUNT
Attn:PERMIT OFFICE Pages:
Fax:619-444-5491 Dote:7/72/09
Comments:
Natural Energy authorizes Joseph James as our representative to pul permits for out clients In the
County of San Diego. If you have any question please contact us.
Thank you.
Ted Mount - Owner Date
SOLAR PHOTOVOLTAIC SYSTEM
PLOT PLAN
DC Disconnect
Inverter
AC Disconnect
Meter
3/4" EMT
J-BOX
PV ARRAY
PV ARRAY
PV ARRAY
FRONT
OF
HOUSE
PV ARRAY
PROVED
DEC03/UIW
City of CARLSBAD
BUILDING DEPT
* #10 USE in free
* #10 Bare copp*
* DC conductors
every five feet
used between modules and J-box
ised to ground all modules
inside of building shall be in metallic conduits and label
UTION DC CIRCUIT"DATE: NOV 12 , 2009
Contact:
Ted Mount
(760)884-
CA LIC #481870
NATURAL ENERGY
147 South Vinewood Street
Escondido, CA 92029
(760)743-6400
(760)743-0871 Fax
PROJECT:
KEVIN SCARSKI
2171 AVflNDA TORONJA
CARLSBAD, CA. 92009
SOLAR PHOTOVOLTAIC 1-LINE
ELECTRICAL DRAWING
4.31 Kw-Ac
Solar PV System
J-Box
SMA 5000
INVERTER
INTEGRATED
DC DISCONNECT
AC Disconnect:
30A-250V
R/R Disconnect\
AC
Exterior:
3/4" EMT
4-#10thhn
1-#10 grnd
Exterior:
3/4"EMT
2-#8 thhn"
l-#8 grnd
METER/MAIN
125A
o
Breaker:
30A-2o Breaker
PV MODULES
22 Solarworld 230w M
(2 string of 11)
VOC= 36.6 Max open circuit 402.6v
CEC rating output: 205.6w @ 29.6V
(mft. STC. rating: 230w fuse rating ISA)
Total rated output: 4523w @ 325V
Contact:
Ted Mount
(760)884-7000 cell
CA LIC #481870
* #10 Stranded USE-2 in free air wire used between
modules and J-box.
* #10 Bare copper wire used to ground
all modules.
* All work to comply with 2008 NEC Codes and
local standards.
NATURAL ENERGY
147 South Vinewood Street
Escondido, CA 92029
(760)743-6400
(760)743-0871 Fax
INVERTER:
1 SMA 5000
DC Input range 250-500vdc
Max AC power output: SOOOw
AC output range: 211-264V
Max continuous output current: 21A
CEC rated efficiency: 95.5%
Total rated output: 4319w @ 240vac
Date: NOV 10, 2009
PROJECT:
KEVIN SCARSKI
2171 AVENIDA TORONJA
CARLSBAD, CA. 92009
CAUTION
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN
DC DISCONNECT
INVERTER
2171 AVENIDA TORONJA AC DISCONNECT
METER
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS
ON BOTH THE LINE AND LOAD SIDES MAY
BE ENERGIZED IN THE OPEN POSITION.
DC DISCONNECT
PV SYSTEM
DISCONNECT FOR UTILITY
OPERATION
Sunmodule/'
SW 220/230 mono
Length
Width
Height
Frame
Weight
65.94 in (1675mm)
39.41 in (1001 mm
1.34 in (34 mm
Aluminum
48.5 Ibs (22 kg)
The Sun module from SolarWorld represents one of the best values in the PV industry.
The Sunmodule's tight power tolerance of +/-3% ensures the highest system
efficiency without the need for on-site module sorting. The fully automated manu-
facturing process at SolarWorld's ISO 9001-2000 factories produces modules with
consistently high quality. Choosing the Sunmodule® will ensure high kWh yields for
the long term.
To guarantee long term yields, Sunmodules are built to last. SolarWorld bonds the
tempered glass laminate deep into the aluminum frame with a continuous bead of
silicone adhesive. This method guarantees exceptional rigidity for the entire module
and prevents the frame from loosening or pulling away from the glass in cases such
as the sliding of heavy snow or handling. Tests carried out in accordance with IEC
61215, which applies loads of up to 113 Ib/sf (5.4 kN/m2) demonstrate that the
module can withstand high loads such as heavy accumulations of snow and ice.
The Sunmodule® features a patented, low profile junction box with integrated 25A
Schottkey bypass diodes that is completely sealed against corrosion. The ability to
rapidly dissipate excess heat allows the diodes and junction box to operate at lower
temperatures. The junction box is reliably connected by a solid, welded bond to
guarantee lasting functionality and is factory-equipped with high-quality, robust
cables and locking connectors. All Sunmodules carry a 25-year performance
warranty and can be returned to SolarWorld at their end of life for recycling
SOLARWORLD
THE SUNPOWERED COMPANY*
SolarWorld. And EveryDay is a SunDay.www.solarworld-usa.com
Sunmodule/'
SW 220/230 mono
Performance under standard test conditions
Maximum power
Open circuit voltage
Maximum power point voltage
Short circuit current
Maximum power point current
SW220
220 Wp
36.6V
29.3V
8.18 A
7.51 A
SW230
230 Wp
36.9V
29.6V
8.42 A
7.76 A
Performance at 800 W/m2, NOCT, AM 1.5
Maximum power
Open circuit voltage
Maximum power point voltage
Short circuit current
Maximum power point current
SW220
157 Wp
33.1V
26.3V
6.76 A
5.98 A
SW230
164Wp
33.4V
26.6V
6.96 A
6.18 A
Minor reduction in efficiency under partial load conditions at 25°C: at 220 W/m!, 95% (+/- 3%) of the STC efficiency (1000 W/m') is achieved.
Component materials
Cells per module
Cell type
Cell dimensions
Thermal characteristics
NOCT
TCISC
TCVOC
TCP™*
60
monocrystalline silicon
6.14 x 6.14 in' (156 x 156mm')
46'C
0.042 %/K
-0.33 %/K
-0.45 %/K
System integration parameters
Maximum system voltage SC II
Maximum system voltage USA NEC
Maximum series fuse rating
Maximum reverse current
Additional data
Power tolerance
Junction box
Connector
1,000 VDC
600 VDC
ISA
Do not apply external voltages
larger than Voc to the module
IP 65
MC type 4
Front
39.41 (1001)
Side
1.34 34) W
Rear
37.80 (960)
Construction
. « 0.26 (6.6)
.80.35(9)
1] Front: tempered glass
2] crystalline solar cells embedded
in EVA (ethylene-vinyl-acetate)
3] Rear: Backsheet
.0 0.35 (9)
.« 0.26 (6.6)
'inches (mm)
IEC 61215
Safety class II
SolarWorld AC reserves the right to make specification changes without notice.
Sunmodules are manufactured in ISO 9001:2000 certified facilities.
This data sheet complies with the requirements of EN 50380
> UL 1741/IEEE 1547
compliant
*
10 yr. standard warranty
> Highest CEC efficiency
in its class
> Integrated load-break
rated AC and DC
disconnect switch
> Integrated fused series
string combiner
> Sealed electronics
enclosure & Opticool
> Comprehensive SMA
communications and
data collection options
> Ideal for residential or
commercial applications
> Sunny Tower
compatible
.
SUNNY BOY 5000US/6000US/7000US
The best in their class
SMA is proud to introduce our new line of inverters updated with our latest technology and designed
specifically to meet IEEE 1547 requirements. The Sunny Boy 6000US and Sunny Boy 7000US are
also compatible with SMA's new Sunny Tower. Increased efficiency means better performance and
shorter payback periods. All three models are field-configurable for positive ground systems making
them more versatile than ever. With over 750,000 fielded units, Sunny Boy has become the benchmark
for PV inverter performance and reliability throughout the world.
Technical Data
SUNNY BOY 5000US / 6000US / 7000US
Recommended Max. PV Power (Module STC)
Max. DC Voltage
Peak Power Tracking Voltage
DC Max. Input Current
DC Voltage Ripple
Number of Fused String Inputs
PV Start Voltage
AC Nominal Power
AC Maximum Output Power
AC Maximum Output Current (@ 208, 240, 277 V)
AC Nominal Voltage / Range
SB 5000US
6250 W
600V
250-480V
21 A
AC Frequency / Range
Power Factor
Peak Inverter Efficiency
CEC Weighted Efficiency
Dimensions W x H x D in inches
Weight/ Shipping Weight
Ambient temperature range
Power Consumption: standby / nighttime
Topology
3 (inverter), 4 x ISA
(DC disconnect)
300V
5000 W
5000 W
24 A, 21 A, 18 A
183-229V@208V
211 -264V@240V
244 - 305 V@ 277V
60 Hz/59.3 Hz-60.5 Hz
0.99 @ nominal power
96.8%
Cooling Concept
Mounting Location Indoor/ Outdoor (NEMA 3R)
LCD Display
Lid Color: aluminum/ red / blue_/ yellow
Communication: RS485 / Wireless
Warranty: 10-year
Compliance: IEEE-929, IEEE-1547, UL 1741, UL 1998, FCC Part 15 A & B
Specifications for nominal conditions
Efficiency Curves
95.5 %
184x24.1x9.5
141 lbs/148lbs
-13to+113 °F
<7W/0.1 W
Low frequency transfor-
mer, true sinewave
OptiCool,
forced active cooling
•/O/O/O
0/0
SB 6000US
7500 W
600V
250-480V
25 A
~ <5%
3 (inverter), 4 x ISA
(DC disconnect)
300V
6000 W
6000 W
29 A, 25 A, 22 A
183-229V@208V
211 -264V@240V
244- 305 V@277V
60 Hz/59.3 Hz-60.5 Hz
0.99 @ nominal power
97.0 %
95.5 % @ 208 V
95.5 %@ 240V
96.0 %@ 277V
184 x24.1 x95
141 Ibs/ 148 Ibs
-13to+113 °F
<7W/0.1 W
Low frequency transfor-
mer, true sinewave
OpfiCool,
forced active cooling
SB 7000US
=
{
8750 W
600V
250 -480V
30A
<5%
3 (inverter), 4 x ISA
(DC disconnect)
300V
7000 W
7000 W
34 A, 29 A, 25 A
183-229V@208V
211 - 264 V@ 240V
244-305V@277V
60 Hz/59.3 Hz-60.5 Hz
0.99 @ nominal power
97.1 %
95.5 %@ 208V
96.0 % @ 240 V
96.0 % @ 277 V
184x24.1x95
141 lbs/148lbs
-13to + 113 °F
<7W/0.1 W
Low frequency transfor-
mer, true sinewave
OpfiCool,
forced active cooling
Included O Option - Not available
1000 2000 PAC!W]
www.SMA-America.com
Phone 9166250870
Toll Free 888 4 SMA USA SMA America, Inc.
BP/TILETRAC® & FASTJACK™ MOUNT COMPONENTS
SLIDING CARRIAGE
3/8' X1-1/2"
THREADED HEX
STUD FOR COM-
POSITION ROOFS
5/16" X 3'
LAG BOLT
TILE TRAC ATTACHMENT BASE
3/8" X 1-1/2"
THREADED HEX HEAD
STUDS
5/16" LOCK
WASHER
3/8" X 6" /
THREADED-
STUD FOR
TILE ROOF
5/16" X 2-3/4"
HEX BOLT
5/16" LOCK
WASHER
INTER-MODULE CLAMPS QTY: 6
5/16" THREAD
SLIDING INSERT CLAMP
QTY: 10
QTY: 2
SUPPORT RAIL 130" LONG
NOTE: BP I.D. LINE
5/16" X 3/4"
HEX BOLTS
MODULE END CLAMPS QTY: 4 SETS
•3/8" THREAD
5/16" X 3"
LAG BOLT
5/16" LOCK
WASHER
FASTJACK STANCHIONS
QTY: 6 SETS
POST HEIGHTS
AVAILABLE
3"
4-1/2"
6"
7-1/2"
Page 2
COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products
(PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029.
FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491.
INSTALLING THE TILE TRAC® ATTACHMENT FEET
3/8" HEX STUD
SLIDING CARRIAGE
5/16" LAG BOLT
5/16" WASHER
TILE TRAC BASE
MASTIC
COMPOSITION ROOF
REFERENCE
PAGE 10 FOR
MORE DETAILED
INSTALLATION
INSTRUCTIONS.
RAFTER
How to attach the TILE TRAC® base to the roof.
After locating the exact position for the TILE
TRAC® bases, drill a 3/16" (we recommend a
carbide masonry bit) pilot hole into the rafter, place
the lag bolt and washer through the base and apply
mastic or roof sealant to the bottom of the base
extrusion. Insuring that the roof is clean and warm,
install base by inserting the lag bolt into the hole
and impacting the lag bolt down using a 1/2" drive
socket (do not over-tighten). After the base has
been secured and sealed to the roof, install the
sliding carriage over the base and thread in the 3/8"
hex stud. At this point, leave the carriage stud
loose to allow for final adjustment. Continue
installing the TILE TRAC® six attachment feet per
rail set installed on 48" centers.
Page 5
COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products
(PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029.
FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491.
INSTALLATION OF THE TILE TRAC® SUPPORTS
TO THE ROOF MOUNTS
1/2" CONE BIT & DRILL
REFERENCE MARK
HEX STUD
"V" GROOVE TO START DRILL
SUPPORT RAIL (BOTTOM)
HNSTALLED SUPPORT RAIL
SHEATHING
TO THIRD SUPPORT
COMPOSITION ROOF
RAFTER
Installation of the TILE TRAC® support rails to the
attachment feet.
After the base has been secured and sealed to the roof,
install the sliding carriage over the base and thread in the
3/8" short hex stud. At this point, leave the carriage stud
loose to allow for final adjustment. Continue installing the
sliding carriages over the TILE TRAC® bases, 6 sets are
required per set of module supports.
Lay the module supports (upside down) next to the TILE
TRAC® supports as illustrated in fig."A" above. Mark the
channel adjacent to the support feet. Align and mark the
intersecting "V" groove on the rail and drill a 1/2" hole
through the rail. (Note: a "Uni-Bit™" sheet metal cone bit
is recommended for this). After drilling the hole in the
support rail, place the rail over the attachment feet (fig.
"B"), make any necessary final adjustments and tighten
the carriage using a 3/16" hex wrench. After the stud has
locked the carriage to the TILE TRAC® base, install the
3/8" washer and nut and tighten using a 9/16" deep socket
wrench. Your support rails are now secure and ready for
installation of the modules.
Page 6
COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products
(PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029.
FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491.
INSTALLATION OF THE MODULES
OVER THE TILE TRAC® SUPPORT RAILS
Attachment and clamping of the solar modules to the
TILETRAC® feet or FASTJACK™ stanchions work
exactly the same. After the support rails have been
installed to the attachments, you are now ready to install
the solar modules. There are two sets of clamps; the
outside clamps (end clamp) and the inter-module clamps
that install between the modules. For convenience, it is
advisable to pre-thread or start the bolt, lock washer and
clamp into the sliding insert prior to bringing them up to
the roof. Slide the two end clamps near the end of the
support rail and install your end module (first). Carefully
square the module to the frame and tighten the clamps
using a 1/2" box wrench or drive socket. DO NOT
OVER-TIGHTEN, we recommend a maximum torque of
20 foot pounds to prevent damage to the module glass.
After the first module is secured, slide two inter-module
clamp sets onto the first module. They are designed to
stay in place freeing you up to slide and align the next
module into place. Repeat this procedure until all
modules are installed onto the support rail. Upon
installation of the last module in the panel, install the
module end clamp to complete the installation.
Please note that all module end clamps are proprietary
and specially extruded to fit a specific brand of module.
Since many of these tolerances are very small, we install
a die line (marker) to differentiate the correct die per
module frame. Please refer to the module end clamp
illustration on page 2 to insure you are using the correct
end clamp.
Page?
COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products
(PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029.
FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491.
INSTALLATION OF TILE TRAC®
STEP1 STEP 2
STEP 1: MARK A REFERENCE LINE ACROSS THE TILES IN THE
VACINITY OF THE ROOF RAFTER. REMOVE THE ROOF TILE BY
PUSHING AND PULLING ON THE TILE: IT IS HELD IN PLACE BY A
SMALL NAIL. LIFT WITH A FLAT NAIL BAR IF NECESSARY.
STEP 3
STEP 2: LOCATE THE CENTER OF THE RAFTER BY TAPPING WITH A
HAMMER OR USING AN ELECTRONIC STUD SENSOR. AFTER
LOCATING THE CENTER OF THE RAFTER DRILL A 3/16" PILOT HOLE
IN LINE WITH THE CHALK LINE.
STEP 4
STEP 3: INSTALL THE LOWER TRACK ASSEMBLY USING A 5/16"
LAG BOLT AND SPECIAL WASHER. PLACE SEALANT AROUND
BOLT AND LOWER TRACK, BE SURE TO SEAL THE NAIL HOLE
FROM THF Til F YOU RFMOVFD
STEPS
STEP 4: AFTER INSTALLING THE LOWER TRACK, SLIDE THE
UPPER MOVABLE CARRIAGE ASSEMBLY INTO POSITION AT THE
HIGH POINT OF THE TILE.
STEP 6
STEP 5: REPLACE THE TILE AND DRILL A 3/8" HOLE USING A
MASONRY DRILL, INTERSECTING THE REFERENCE LINE AND THE
HIGH POINT OF THE TILE.
STEP?
BIND
STEP 6: INSERT THE THREADED SHAFT THROUGH THE HOLE IN
THE ROOF TILE, LOCATING THE UPPER TILE TRAC® CARRIAGE.
IF NECESSARY, PICK UP THE ROOF TILE TO ASSIST IN STARTING
THE THREADED SHAFT. INSERT AND LOCK TWO 3/8" NUTS ON
THE THREADED SHAFT AND TIGHTEN DOWN USING A 9/16"
WRENCH.
STEPS
REFER TO PAGE SIX
FOR INSTALLATION
OF THE SUPPORT
RAIL
STEP 7: INSERT AND LOCK TWO 3/8" NUTS ON THE THREADED
SHAFT AND TIGHTEN DOWN USING A 9/16" WRENCH.
STEP 8: APPLY SEALANT AROUND THE THREADED SHAFT
COMPRESSING THE SEALANT WITH THE ENCLOSED 3/8"
WASHER.
Page 10
COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2002: All information contained in this manual is property of Professional Solar Products
(PSP). TILE TRAC® is a registered trademark for PSP and is covered under U.S. patent #5,746,029.
FASTJACK® is a registered trademark for PSP and is covered under U.S. patent #6,360,491