Loading...
HomeMy WebLinkAbout2173 SALK AVE; ; CB071222; Permit05-18-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB071222 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2173SALKAVCBAD Tl Sub Type: 2120210200 Lot#: $9,000.00 Construction Type: Reference #: VENTANA-ACCESS CONTROL-LOCKING HARDWARE INDUST 0 NEW Applicant: DAVISREED CONSTRUCTION INC 12250 EL CAMINO REAL SUITE 325 SAN DIEGO 92130 760-931-8424 Status: ISSUED Applied: 05/02/2007 Entered By: RMA Plan Approved: 05/16/2007 Issued: 05/16/2007 Inspect Area: Plan Check*: Owner: RIO SD PLAZA II MASTER LLC C/0 NEWPORT NATIONAL CORPORATION 1525 FARADAY AVE #100 CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $91.99 Meter Size $0.00 Add'l Reel. Water Con. Fee $59.79 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $1.89 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 ?? $153.67 Total Fees:$153.67 Total Payments To Date:$153.67 Balance Due:$0.00 BUDDING PL/ J^INSTORAG7 ATTACHED Inspector:JU FINAL APPROVAL Date: &Clearance: NOTICE: Please take NOTICE mat approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. City of Carlsbad • 1635.Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718/2719 Fax: 760-602-8558 Building Permit Application PlanCheckNo.(^/r?7 \ 1 1 2 Est. Value 00® Plan Ck. Deposit Date JOB ADDRESS PHASE* SUITE#/SPACE#/UNIT# CT/PROJECT*"LOT## BEDROOMS # BATHROOMS TENANT I USINESS NAME TYPE OF CONST.OCC. GROUP DESCRIPTION OF WORK: (Please describe present use and proposed use) COWTJ20L BUILDING AREA (SF)ADDITION AREA (SF)GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YESO #NOC1 AIR CONDITIONING YES D NO D FIRE SPRINKLERS YES D NOD CONTACT NAME APPLICANT NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATEeft ZIP PHONE FAX EMAIL EMAIL OWNER NAME CONTRACTOR BUS. NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC. #STATE LIC.#CITY BUS. LIC.# (Sec 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he islicensed pursuant to die provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of die Business and Professions Code} or that he is exempt dierefrom, and the basis for the alleged exemption. Any violation ofSection 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {{500}). WORKERS' COMPENSATION Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Hi I have and will maintain workers' Compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy numberare: InsuranceCo. V fOHV £ • pOtfTMJM f «T*A PolicyNo. „ u /ji,^r r^d Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. -~C 3. r- U& " ' " /c'>5/ d Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&1 00,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. - £ - & J^CONTRACTOR SIGNATURE OWNER-BUILDER DECLARATION / hereby affirm that I am exempt from Contractor's license Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement, n Yes O No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): >Ef PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? a Yes a No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes n No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O Yes n No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CtTY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA- An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ^APPLICANT'S SIGNATURE # *?<faW>DATE envoi Carlsbad Final Building Inspection Oept: Building Engineering Plan Checks- Permit*: CB071222 Project Name: VENTANA-ACCESS HARDWARE Address: 2173SALKAV Contact Person: Sewer Dist: CA Inspected /t^f/? /Inspected By: Inspected By: / / ~f^ /Comments: A J£> f~t/!L£, //U Planning CMWO CONTROL-LOCKING Phone: Water Dist: CA Date / /' Inspected: £»//*//<£ Date / Inspected: Date Inspected: ^£r/-~7>^ ^ StLite^KMk Date: Permit Type: Sub Type: Lot: 0 y7 Approved: x^ Approved: Approved: cj^Df^y^^y\ 06/14/2007 Tl INDUST Disapproved: Disapproved: Disapproved: EsGil Corporation In (Partnership with government for (RuiUing Safety DATE: 5/10/O7 O APPLICANT JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 07-1222 SET: I PROJECT ADDRESS: 2173SalkAve PROJECT NAME: Ventana Building A - Controlled Access Hardware !Xl The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. HI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I | The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Doug Moody Enclosures: Esgil Corporation D GA D MB D EJ D PC 5/3/07 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 07-1222 oflO/07 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody BUILDING ADDRESS: 2173SalkAve PLAN CHECK NO.: 07-1222 DATE: 5/10/07 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: Unknown BUILDING PORTION Access Hardware Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) N/A cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) #VALUE! #VALUE! Plan Check Fee by Ordinance Type of Review: Repetitive Fee Repeats D Complete Review D Other m Hourly Structural Only 0.5 Hour* Esgil Plan Review Fee * Based on hourly rate Comments: $60.00 $48.00 Sheet 1 of 1 macvalue.doc Carlsbad Fire Department BUILDING DEPT. ' ' COPY Plan Review Requirements Category: TI, INDUST Date of Report: 05-09-2007 Reviewed by: /$ Name: Address: Permit #: CB071222 Job Name: VENTANA-ACCESS CONTROL-LOCKING Job Address: 2173 SALK AV CBAD «|fem you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0002065 [MET] * FIRE DEPARTMENT INSPECTION REQUIRED * "" -^ APPROVED: • THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 05/09/2007 By: GR Action: AP VENTANA 2177SALKAVE. tOTA Carlsbad, CA. 92008 Security Locking Hardware Submittal CJ Submitted By; SYSCOR ALARM, Inc. P.O. Box 338 Cardiff, CA. 92007 Lie. C-10 #773773 VENTANA Security Locking Hardware Submittal Equipment List Description Control Panel Card Reader Panic Bar Electric Strike Power Supply Model # Northern N-750 Northern PR-MINI-PROX Von Duprin 33A-NL-DP Folger Adams #310 Von Duprin # PS873-2 Access Flexibility and technical effectiveness make the N-750 the smartest choice for virtually any application. The N-750 offers stand-alone security or seamless integration with access control. For multi-tenant build- ings, one N-750 installa- tion can be partitioned to provide up to 8 multiple, independent systems. A campus looking for one solution to service hundreds of people can turn to the N-750 for customized time schedules and user profiles. As a management tool, the N-750 can report facility and personnel activity, system status and system account tracking. Simple readouts at touchpads communicate system status with complete, easy-to-understand state- ments. Single-function keys at touchpad stations eliminate the need for code memoriza- tion or multi-step operations. The basic configuration options of the N-750 center around four simple features. These four simple feature* aie building blocks engineered for complete flexibility. .NO a system can be tailor-made tor your application. Security Po-.iUi - A security point is simply a single point o; protection. For your security needs it might be a contact switch on a window or a motion detector, or even the lock contiol on a door. And with addressable points, the activity and condition of individual security points can be identified. LO'~-;::'-. - A zone is one or more security points grouped together in an electrical circuit. For example, the door.-,, windows and other security points in a coniereuce room co:uj. be identified as a specific zone. •:•:.•''•••'.- - An area can either be classified by a group of.-,ecun:\ points, or by one or more zones. You can control your area> individually as well as grouping them together. r3n;T:O'!?> - The N-750 brmg.i yon true partitioning m a sinule system. A partition is an area or group ot areas conlig- ured into an autonomous system. For example, a management company for a high-rise can invest in one N-750 system to provide individually programmed, monitored and billed .iccc.v-. control and security services to each o:'ns tenant.-,, in ilu> ;Y:V- of environment, the cost savmg.v maintenance and reliabih;\ of the N-750 is years ahead of any other technology. What used to take a number of systems, multiple vendors, and a variety of service and monitoring contracts, now can be handled with one system from one company. N-750-PAIT Reader TOUCHPADS/ CARD READERS (max. 24 per system) PRINTER far direct connection lo ACAS Software beatures 16 supervised programmable zones, expandable to 400. Eight true partitions with up to eight areas per partition (64 possible areas). Up to 1,800 users or cards. High speed RS-485 bus to connect touch- pads, zone expanders and other accessories. Up to 24 touchpads and/or card readers. 50 time schedules with 20 ranges per schedule. Auto or manual lock/unlock. Local and Global anti-passback. Duress feature. UL Listings • UL 294 Access Comro! • UL Grade A • UL 365 Police Connect • UL 609 Local Burglary •UL611 C.S. Burglary • UL 636 Holdup Alarm Units • UL 681 Bank Burglar Systems • UL 864 Comm. Fire C.S • UL 985 Household Burglary • UL 1023 Household Burglary •UL 1076 Proprietary- Burglary •UL 1610 C.S. Burglary •UL 1635 Digital Burglary System • ULC Res./Comm. Burglar)' •FCC Part 15 • FCC Part 68 • DOC CS-03 • CSFM Res./Comm. Fire Panel Specifications Dimensions 15"W x 20'H x 3"D Weight 17lbs. Power 18VAC, 60Hz, 50VA Temperature 32" to 120° F 0° to 49° C Humidity 85% non-condensing Ordering N-750 Security/Access Control Panel N'750-PAIT Programming & Access Touchpad for the N-750 N-750-ADM Door Access Module for the N-750 N-750-PI Serial/Parallel Interface for Printer or Direct Connect to N-750 N-750-ACAS Administration Software for the N-750 N-750-SK Remote Upload/Download Software for the N-750 N-750-APS 12VDC Auxiliary Power Supply for the N-750 N-750-APS-24.... 24VDC Auxiliary Power Supply for the N-750 N-750-ZONE 64 Zone Expander for the N-750 N-750-SS Smart Sensor for the N-750 & N-750-SSE N-750-SSE 128 Point Expander for the N-750 N-750-DPLM Dual Phone Line Module for the N-750 N-750-BELL Bell Supervision for the N-750 COMPUTERS, INC.5007 South Howell Ave. Milwaukee, VVI 53207 tel: (414)769-5980 fax: (414) 769-5989 VISION SYSTEMS ARCHITECTURAL PRODUCTS Vision Systems, Incorporated 1895 Gillespie Way • El Cajon, CA 92020 Tel 619.258.7300 • Fax 619.562.2630 www.visionsystems.org • CA License No. 482277 Ventana Real Buildings A Carlsbad, California Architect: Contractor: Glazing Contractor: Project Number: Nadel Architects 625 Broadway - Suite 1025 San Diego, California 92101 Davis Reed Construction Inc. 12250 El Camino Real - Suite 325 San Diego, California 92130 Vision Systems, Inc. 1895 Gillespie Way El Cajon, California 92020 A0605 DOOR HARDWARE Section 08710:Finish Hardware Submittal Number:A0605-HDW-001A Vision Systems Hardware Schedule Building A Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Section: 08710 Paae2of49 L. Door Group: 1 fccription: Medium Stile Door Opening Size: 36' x 96* Ventana Real Bldg A Ke: Offset Door Operation: Single - Right Hand Reverse VSI Project No. A0605 Manufacturer: Vision Systems, Inc. Door Finish: 70% Kynar Fluropon by Valspar color: UC51 568: XL Champagne Gold 9/7/2006 Door Infill: 1' IGU VE1-2M by Viracon DOOR NUMBER 119 QUANTITY 1 SINGLE or PAIR Single ELEVATION /SHEET Elevation T / Sheet E-20 Hardware Set: 5 QUANTITY/SET 1 1 1 1 1 1 1 1 1 MANUFACTURER Dorma Dorma Von Duprin Von Duprin Von Duprin Schlage Trimco Rixson Pemko DESCRIPTION Intermediate Pivot Floor Closer 3/4 Offset 90 deg hold open Panic Device Power Supply Power Transfer Rim Cylinder Door Pull Overhead Stop Threshold PART NUMBER 75220 BTS75VBF-NHO/D-LFP EL35A-NL-OPxRXx24VDC PS873-2 EPT10 20-022 1 191-4 J Mount 1-336 272A FINISH 626 626 626 GRY 689 626 629 689 Mill SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems REMARKS: Weatherseal by Vision Systems Door Group: 1 A Description: Medium Stile Door Opening Size: 36" x 96" Ventana Real Bldg A Type: Offset Door Operation: Single - Left Hand Reverse VSI Project No. A0605 Manufacturer: Vision Systems, Inc. Door Finish: 70% Kynar Fluropon by Valspar color: UC51568: XL Champagne Gold 9/7/2006 Door Infill: 1" IGU VE1-2M by Viracon DOOR NUMBER 102 QUANTITY 1 SINGLE or PAIR Single ELEVATION /SHEET Elevation T-N/ Shet E-20 B Hardware Set: 5 ^QUANTITY/SET 1 1 1 1 1 1 1 1 1 MANUFACTURER Dorma Dorma Von Duprin Von Duprin Von Duprin Schlage Trimco Rixson Pemko DESCRIPTION Intermediate Pivot Floor Closer 3/4 Offset 90 deg hold open Panic Device Power Supply Power Transfer Rim Cylinder Door Pull Overhead Stop Threshold PART NUMBER 75220 BTS75VBF-NHO/D-LFP EL35A-NL-OPxRXx24VDC PS873-2 EPT10 20-022 1 191-4 J Mount 1-336 272A FINISH 626 626 626 GRY 689 626 629 689 Mill SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems REMARKS: Weatherseal by Vision Systems Door Group: 2 Description: Medium Stile Door Opening Size: 36" x 96" Ventana Real Bldg A Type: Offset Door Operation: Single - Left Hand Reverse VSI Project No. A0605 Manufacturer: Vision Systems, Inc. Door Finish: 70% Kynar Fluropon by Valspar color: UC51568: XL Champagne Gold 9/7/2006 Door Infill: 1/4" VY1-20 by Viracon DOOR NUMBER 301 302 QUANTITY 1 1 SINGLE or PAIR Single Single ELEVATION / SHEET Elevation R6/ Sheet E-1 9 Elevator A3L/ Sheet E-1 3 Hardware Set: 6 QUANTITY/SET »j MANUFACTURER Dorma Dorma Adams Rite Trimco Rixson Pemko DESCRIPTION Intermediate Pivot Floor Closer 3/4 Offset 90 deg hold open I.C. Rim Cylinder Door Pull Overhead Stop Threshold PART NUMBER 75220 BTS75VBF-NHO/D-LFP MS 1850S-416 1 191 -4 J Mount 1-336 272A FINISH 626 626 626 629 689 Mill SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems REMARKS: Weatherseal by Vision Systems Vision Systems, Inc. CA^iinn. r\Q~7-tr\ Ventana Real D^na t nf A*~> A0605/7-HDW-001 ^ Door Group: 2A : Medium Stile Door Opening Size: 36' x 96' Ventana Real Bldg A it Door Operation: Single - Right Hand Reverse VSI Project No. A0605 Manufacturer: Vision Systems, Inc. Door Finish: 70% Kynar Fluropon by Valspar color: UC51 568: XL Champagne Gold 9/7/2006 Door Infill: 1/4' VY1-20 by Viracon DOOR NUMBER 101 303 QUANTrnr 1 1 SINGLE or PAIR Single Single ELEVATION /SHEET Elevation S / Sheet E-20 Elevation A3R/ Sheet E-1 3 Hardware Set: 6 QUANTITY/SET 1 1 1 2 1 1 MANUFACTURER Dorma Dorma Adams Rite Trimco Rixson Pemko DESCRIPTION Intermediate Pivot Floor Closer 3/4 Offset 90 deg hold open I.C. Rim Cylinder Door Pull Overhead Stop Threshold PART NUMBER 75220 BTS75VBF-NHO/D-LFP MS 1850S-415 1 191-4 J Mount 1-336 272A FINISH 626 626 626 629 689 Mill SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems REMARKS: Weatherseal by Vision Systems Door Group: 2B Description: Medium Stile Door Opening Size: 46" x 96" Ventana Real Bldg A Type: Offset Door Operation: Single - Left Hand Reverse VSI Project No. A0605 Manufacturer: Vision Systems, Inc. Door Finish: 70% Kynar Fluropon by Valspar color: UC51 568: XL Champagne Gold 9/7/2006 Door Infill: 1/4" VY1-20 by Viracon DOOR NUMBER 211 QUANTITY 1 SINGLE or PAIR Single ELEVATION /SHEET Elevation PI Sheet E-1 2 Hardware Set: 6 •EATmroSET" Pi 1 2 1 1 MANUFACTURER Dorma Dorma Adams Rite Trimco Rixson Pemko DESCRIPTION Intermediate Pivot Floor Closer 3/4 Offset 90 deg hold open I.C. Rim Cylinder Door Pull Overhead Stop Threshold PART NUMBER 75220 BTS75VBF-NHO/D-LFP MS 1850S-416 1 191-4 J Mount 1-336 272A FINISH 626 626 626 629 689 Mill SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems REMARKS: Weatherseal by Vision Systems Door Group: 3 Description: Medium Stile Door Opening Size: 36" x 96" Ventana Real Bldg A Type: Offset Door Operation: Single - Left Hand Reverse VSI Project No. A0605 Manufacturer: Vision Systems, Inc. Door Finish: 70% Kynar Fluropon by Valspar color: UC51 568: XL Champagne Gold 9/7/2006 Door Infill: 1/4" VY1 -20 by Viracon DOOR NUMBER 103 QUANTITY 1 SINGLE or PAIR Single ELEVATION (SHEET Elevation S / Sheet E-20 Hardware Set: 11 QUANTITY/SET 1 1 1 1 2 1 1 MANUFACTURER Dorma Dorma Von Duprin Schlage Trimco Rixson Pemko DESCRIPTION Intermediate Pivot Floor Closer 3/4 Offset 90 deg hold open Panic Device I.C. Rim Cylinder Door Pull Overhead Stop Threshold PART NUMBER 75220 BTS75VBF-NHO/D-LFP 33A-NL-OP 20-022 VTQP Keyway 1191-4 J Mount 1-336 272A FINISH 626 626 626 626 629 689 Mill SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems JMUVRKS: Weatherseal by Vision Systems Vision Systems, Inc.Ventana Real Pane Anf 49 A0605/7-HDW-001 Door Group: 4 Description: Tempered Glass Door Door Opening Size: 72" x 96" Ventana Real Bldg A Type: Center Hung Door Operation: Grandview "P" Doors Pair - Reverse VSI Project No. A0605 Manufacturer: Grandview Glass Door Finish: Polished Aluminum 9/7/2006 Door Infill: 1/2" clear monolithic tempered DOOR NUMBER 106111 QUANTITY 1 1 SINGLE or PAIR Pair Pair ELEVATION f SHEET Elevation Ml Sheet E-8 Elevation W / Sheet E-9 Hardware Set: 1 QUANTITY/SET 2 1 1 1 1 2 MANUFACTURER Dorma CR Laurence CR Laurence Folger Adams Grand View Schlage DESCRIPTION Floor Closer Center Hung 90 deg hold op Panic Handle Panic Handle Electric Strike Top/Bottom Rails Cylinder PART NUMBER BTS75VBF-NHO/D-LFP PA100D3RKBS PA100D4RKBS 310-1 GV-150 B502-191 CAM/20-001 FINISH 626 630 630 630 630 626 SUPPLIED BY Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems Vision Systems REMARKS: Power Supply and Card Reader by others Vision Systems, Inc.Ventana Real A0605/7-HDW-001 Section 08710: Door Hardware Vision Systems Hardware Schedule Adams Rite CR Laurence Dorma Folger Adams Grandview Ives Pemko Rixson Schlage Trimco Vision Systems, Inc. Von Duprin Vision Systems, Inc. Ventana Real A0605/7-HDW-001 CR Laurence Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Section: 08710 Page 10 of 42 3/12/2007 CRL Panic Handles SPECIFICATIONS: Material: 1-1/4" (32 mm) Diameter Brass or Stainless Steel Tubing (1.5 mm thick) Glass Thickness: MZ (12 mm) or 3/4" (19mm) Glass Fabrication: Varies. Please contact CRL Technical Sales Certification: ANSI/UL305 • For 1/2" (12 mm) or 3/4" (19 mm) Tempered Glass Doors • Can Be Used as a Replacement for Older Panics • Available in Polished or Brushed Stainless Steel, Satin and Polished Brass • Stock Sizes Available for Immediate Shipment • Custom Sizes Ship Within Two to Four Weeks • Optional Keyed Access and Electric Strike • Available with a Wide Selection of Exterior Fixed Pull Handles on Special Order Our new Glass Door Panic Handles are designed to allow maximum view and a contemporary look to 1/2" or 3/4" (12 mm or 19 mm) tempered glass doors. Installations can be made on single or double doors. For your convenience, we have designed the handles so they are ready to install on 36" to 48" wide doors ranging in height from 90" to 102" high without modifications. "Dogging", locking the device in the open position, is easy with just a slide of a knob. A Door Stop/Strike (see below) must be ordered separately. Threshold Strike Plate available for PA110 Series. Custom Headers available with your choice of pre-installed hardware. STANDARD MODELS Contact CRL Technical Sales for specification details and pricing on these new handles for "All Glass" Entrance Doors. Please call (800) 421-6144 in the U.S., or (877) 421-6144 from Canada, and ask for Extension 777, or e-mail techsales@crlaurence.com. AVAILABLE OPTIONS (RH Shown) PA100 SERIES PA110 SERIES SECURES AT TOP OF DOOR SECURES AT BOTTOM OF DOOR ORDERING OPTIONS When ordering Panic Handles you must specify: PA100 or PA110 Series (shown above); Exterior Handle Option (shown on page DC29); Right or Left Hand (as viewed from the outside); Rail Mount (for doors with full length rails) or Glass Mount (for doors with patch rails); Standard Retainer Plate or optional Keyed Access Device; Brushed or Polished Stainless, Satin or Polished Brass finish. Optional Threshold Strike Plate (PA110 Series Only). Let our Technical Sales Specialists assist with selecting the right Panic Handle. We can quote your requirements for every application. Single or Double Door Electric Strike Keepers Single or Double Door Stop/Strike Vision Systems, Inc. Section' 08710 Ventana Real Paae 11 of 42 A0605/7-HDW-001 3/12/2007 MS 1850S Deadbolt DIMENSIONS INSTALLATION INCHES MILU METERS to tolerance extremes. rL,J .iHOWNWITH FUtt FACEPLATE BACKSET MEASURED .34 S.4 i I 11 3.0 6.00 15>.4 rh xtx CijrP 0°0 .25 6.3-* r AT CENTERUNE Of STILE NOSE .225.6 6. 16 / 1.41 35.B SI2.0 ^ CAM TOLERANCE: '.DOS PUT RADIUS MOIUS*/WHTHBWTIWM91I51SW LH BEVEL MSU52S-015 HH BEVEL MS1I52S-016 <i CYLINDER Cylinder Cam MSI850S Series locks are operable by any standard 1-5/32" diameter mortise cylinder with special MS* cam dimensioned as shown. Cylinders with MS* cams can be readily obtained from most cylinder manufacturers. See page SW-32 for cylinder make and trim ring information. LOCK & STILE I ..• ' BACKSET \ 1.25 31.7 OIA. HOLE CUTOUT TOLERANCE: + .015 + 0.38 -.000 -0.0 Stile Preparation ' $ CYLINDER Lock & Cylinder Preparation HOW TO ORDER Specify quantity and fAie fbllov/ing information. Order related hardware separately. Faceplate Shape ; 185OS Mat i lasts Radius i 1851SW Radius w/w'stnp 1852S Bevel ckset 31/32" I-1/8' 1-1/2- Handing 15 LH or RHR 16 RHorLHR 10 Non-Handed- MS1850S-215-628 •Any flat or radius face, except Schooifiouse. Finish : 628 Clear Ancxted \ 313 Dart Bronze Anotod I 335 Efeck Anodized ! (806 10 SW MS IB50S SEMES »TE MANUIAQUBNG CO • PBtVTED INU.5A OPTIONS For jambs too narrow to accept the long bolt, the MS 1850S-050 offers a shorter bolt with hook shape to provide equal security against door-prying attempts. (See catalog page SL-I.) 1850S- 020 short throw without hook also available. Second and third point locking bolts are available for pairs of doors. (See pages S W-10 and SW-11.) Ail use any make standard mortise cylinder and thus can be keyed into systems with other types of doors. •SCHOOLHOUSE" version, also available, is modified so that operation from inside is "unlock only." I'his lock is handed and must be specified LH or RH. Specify Series SCH 1850$ Same facepUite ..ind backset options as Series MS 1850$. Operation from inside, with standaid AcLims Rite 4066 Turn seen on page SW-32 or with 4550 Deadbolt Lever (rviqe SW-15). For wood or hollow metal, see MS i H50SN. STANDARD PACKAGE IndividLially boxed with machine screws for mounting. Cylinders and/or thumbturn available at extra cost. Shipping weight: 1-1/2 Ibs. Also available in a 25 unit pack for volume users. Vision Systems, Inc. Section: 08710 Ventana Real Page 9 of 42 A0605/7-HDW-001 3/12/2007 Adams Rite Vision Systems, Inc. Ventana Real A0605/7-HDW-001 ^/IA 7 r\f AD Dorma Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Section-08710 Paae12of42 3/12/2007L TS80 BTS 75 V Vision Systems, Inc. Section: 08710 Ventana Real Page 13 of 42 A0605/7-HDW-001 3/12/2007 DORMA BTS 30 DORM A BIS 75 V Floor Spring! Universal application, individual functions and assured quality Tnarnu to i wide range or functions, mulch can be Individually selected to suit different requirements, CORMA BTS 80 and BTS 75 v floor springs offer Whether standard, narrow or wide, wtiether LH, RH, or single or double action - DORMA BTS BO and BTS 75 v door springs are designed Tor m types of door. A comprenenstve program of accessories ensures tn»t they cm be used successfully with * vide variety of door destructions and floor coverings. ... for 1r» trade » Reduced stock require- ments because of separata, interchangeable spindles. * Slim product range offering all key functions. ...JwttietostWttf * Suitable for Installation with LH or RH single and double action doors. * interchangeable spindles enable easy adaptation to structural conditions - even when retrofitted. maximum reliability and quality. Certified to ISO 9001. • Concealed Installation for maximum visual elegance • All essential functions provided » Frown, robust design capable ef withstanding leaf weights or up to JOO kg (BTS 80). ...la the user • Constant, ternpsrature- independent closing c'f-*e- • Highly efficient mechanism gives maximum user convenience. Data and features BTS 8TS I 80 75 V Spring strength (EN) Spring strength adjustment Standard and s, 950 mm external doors1' 1 1100 mm s 14OOmm Fire and smoke check doors Max leaf welgnt (KB Non-handed, suitable for single and double action doors Closing speed 175* - 0' adjustable by valve 175* - 15' 15' -0' Backcheck, mechanical Delayed action adjustable by vata (selectable alternative to tne row-open feature) Hold-open Adjustable Find 90* Fixed 105* ccverplate secured to cement box floor spring YSItfrt In kg Dimensions in mm Length Width , Height Floor spring tested to EN 11 54 (I martins ror building products 3 4 » - - • - - - - 300 6 - - » - * • - - • *» - - • - 7.1 341 78 GO * 1-4 • - •- • 120 » - • * * - • • *- 3.0 285 82 50 *In preparation * yes - no |-Fa applications involving particularly high or heavy loads, and doers which have to close against rtnd or draught conditions, the netf larger spring strength should be selected. 7i SMt BTS BIV75 VIBI, G« Vision Systems, Inc. Section- 08710 Ventana Real Paoe 14 of 42 A0605/7-HDW-001 3/12/2007 Application and Installation URhmsal cmr pM» Adaptable to right or left hand single action applica- tions By simply snapping on tne appropriate pre-DHnMed corner sections. For double action door*, the earner sections remiln in place. A rang* of interchangeable spindles Is available to pro- vide greater floor clearance IT required {eg. doers with thresholds, carpeted floors etc). DORMA 2300 sealing compound For (II ling cavities between tne floor spn ng cod/ and tne cement tea to protect agartst rrotitLie penetntlon. The unrwriil cover plate la ivallatte In stalnlea steel or sartln brass (rnatEftal thickness 1.5 mm). special spindles amiable on application: e.g. with flat face profile and 3' onset or square section-, spindles for non-CORMA-spectffc accessorlis u* also anllable. in Y////// SptrOlgBtension-DlineiistosTr-Srnmj (Door dtwanei} z- 3mm information about otner accessories such as dour straps and top centra can be found in tne "Accessories lor DORMA BTS Floor Springs' leaflet Vision Systems, Inc. Section: 08710 Ventana Real Page 15 of 42 A0605/7-HDW-001 3/12/2007 • - Flow spring wttn spindle BTS so specification ted Universal non-handed floor spring conforming to DIN EN 1154 for single and double ictlcn doers up to max. 300 kg leaf weight. Witt id|ustable closing speed and closing action from ipprox 175*, wttn nydrautbally fully controlled closing cycle and bacteheck. Wltn Integral pressure compensitlon feature for temperature-l n dependent hoU-open between 75* and 175'Cr*iroval>le).WIth adjustabte noU-open start paint and deliyed action tend of delayed action range adjustable between 75' and IG6*). including cement Cox -Accessories Sin DEN 3 DEN 4 DENS ACCtiSSMtti D Spindle D standard D... mm extension D special model... D Universal cover plate (l.smrntniel!) D stainless steel G satin brass D Sealing compound Mate: DORMA BTS SO DORMS. 8T5 75 v specification tea universal floor spring conforming to DIN EN 11M, non-rtinded unit suitable for LH and RH single and double action doors up to 120 Kg leaf weigut, with adjustable spring strength (sin EN 1 - 4) and closing speed, tMffi closing action operational frcm approx 175*. Featuring nydraull- calty fully controlled closing cycle and backcnecK. including cement box, without spindle. Models D Fixed noid-open at 90' D Fined hold-open at 105' Aeceisortet D Spindle Qsttndard D... mm extension O special <Jeslpi... n Unlwrsal cover plate (l.SmmtilcK) D stainless steel D satin trass D Seal Ing corn pound Make: CORMA BTS 75 V Vision Systems, Inc. Section: 08710 Ventana Real Paae 16 of 42 A0605/7-HDW-001 3/12/2007 ttandarct ana optional tuncttons <a ms BTS 75 V 1O5" 1 Adjustable closing speed 2 Hold-open tangs or delayed action tinge HytMuBc MM-opm Tut integrated Mid-open (unction allows the HOOT to be hen open ait any ingle between vy »na 175V. The angle A which the raid- open luncton begins can tx adjustsd in the urge at 75' to 105». 1 Adjustment tinge - pant at vmicti now-open oeglra, at end of delayed action range ftpp»m 75* Trie integfstBO mectianicil bacHcneck function protects the mil and door ttorn dsmagt caused by eujessheiv vigcrcus opening. 1 MT|usta&te closing K«sd m*K range 175*-15*. 2 Mjustacte closing spe*a Wtti two independently trie DORM* ats 75V is Ideally adaptable ta dtrterent stiuctural candltlcre. 4 Mechanical bacKctwcK cmjnt ippnn. sen trie. dEUyed action tuncDon stems the floor closing speed. tnenBy slowing disabled persons, mctrwts with puaxtwlre, •stiff with troneys w hospital gumeys ete . ta pis trrou0\ the doer wttnout problem. Hie I oteyatea rnecnanlcil backcneck (unction protects trie will and door Horn damage caused ty es-essl- iMy vlgarans opening. a Mechanical bacKchecK flran appim. TO1}. 4 FUcd rota-open at 9cr or 105* (cffflon). 5 Adjustable spring Utengm Find tola-open ippflon) With trie Ited Main-open tunction the door can be h«td open it an angle 0 90" or 106* , depending on model. twt uttaMelw UM on Flie ttton. The DORM*. BTS 75V IS CERT1F1RE appmed ,;cert«icate No. door tjpes tTT 120. inc.Ventana Real Page 17 of 42 A0605/7-HDW-001 3/12/2007 Components Drawings DORMALM Series 3/4" Offset Full-Mortise 13/16 E 4-1/4 (108) © © @ © • ' / ^r L/4~\$i (I9>•—4 1-1/16 (27) No. 75120 — 3/4" offset standard bronze top pivot. No. 75122 — 3/4' offset bronze top pivot. U.L. listed for 20 minute rated fire doors. No. 75133 — 3/4' offset steel top pivot. For use on lire doors rated up to three hours. Not*: Standard pivots are non-handed and designed for flush door and frame conditions. For 1/8' inset pivots, add 5/8 suffix and hand, i.e. 75120 5/8 RH. No. 75220 — 3/4' offset standard bronze intermediate pivot. No. 75222 — 3/4' offset bronze intermediate pivot. U.L. listed for 20 minute rated fire doors. No. 75233 — 3/4' offset steel intermediate pivot. For use on tire doors rated up to three hours. (Specify Hand) 13/16 ifK « s» . ) ©f ^J II 3/,4 XOVER 095 -3/8 (162) © © 097 1 13/16 (21) (21) 13/16 113/32 (10) No. 75323 — 3/4' offset standard steel bottom arm. Can also be used on fire doors rated up to three hours. For use with 7471K floor bearing. (Specify Hand) (305) LCZte I h-3/8 (35) 11/32 J-r No. 75333 — 3/4' offset heavy-duty steel bottom arm. Can also be used on fire doors rated up to three hours. For use with 7471OH floor bearing. (Specify Hand) 12 Vision Systems, Inc. Section: 08710 Ventana Real Page A0605/7-HDW-001 Folger Adams Vision Systems, Inc. Ventana Real A0605/7-HDW-001 ^prtinn-flft7in Paae19of42 3/1?/?n(V7 FOLGER ADAM 1C HOUR I'Ot-iTRi mortis* tack*with dMdbohs SLburglary rated 310-2 For a 1/2" or 5/8" throw latchbolt (without deadbolt) on single and pairs of doors. 310-2-3/4 For a 3/4" throw latchbolt (without deadbolt) on single doors. 310-2 3/4 OB For a pair of doors, without a door coordinator, which are equipped with a lock having a 3/4" throw latchbolt (without deadbolt). 310-2 3/4 U For use with a pre-assembled or unit lock (not shown). 310-3-1 For a lockset with both a 3/4" throw latchbolt and a 1" throw deadbolt. •Deadbolt must be retracted manually. •Position of block within cavity is adjustable to properly locate auxiliary latchbolt for deadlocking purposes. *Nota: Those product will rused with mortise locks.relocation of tho conter fino, when 310-2 310-23/4 310-2 3/4IB 310-2 3/4U 3104-1 Vision Systems, Inc. Spctiorv 08710 Ventana Real Paae 20 of 42 A0605/7-HDW-001 3/12/2007 FOLGER ADAM Specifications •DoD FSC 5340 •UL 10C Listed for fire door assemblies up to 3 hours. (310-2, 310-2 3/4, 310-2 3/4U and 310-3-1 NFS Models only) •UL1034, burglary resistance rated .ANSI/BHMAA156.31 - Grade 1 •NFPA-252 Fire door conformant •ASTM-E152 Fire door conformant •300-86-SA - City of New York - BSA Product Features •Tamper resistant, heavy-duty construction •Constructed entirely of stainless steel for strength and corrosion resistance •Horizontally adjustable keeper to allow for door and frame misalignment •3/4" (19mm) keeper depth (310-2 3/4 & 310-2 3/4OB) •1/2" (13mm) keeper depth (310-2) •Non-handeo", reversible •Fail Secure (standard) •Fail Safe (FS-optional) •Plug-in connector •Five year limited warranty Optional Features MONITORING •LCM Locking Cam Monitor •LBM Latchbolt Monitor •LCBM Latchbolt & Locking Cam Monitor •LCBMA Latchbolt & Locking Cam Monitor with Auxiliary Switch OPTIONS •Extended Lip (must specify length) Voltages .DC: 12D (.51A), 24D (.25A) Faceplate Finishes •605 (US3) Bright brass •606 (US4) Satin brass, clear coated •612 (US10) Satin bronze, clear coated •613 (US10B) Oxidized satin bronze, oil rubbed •629 (US32) Polished stainless steel •630 (US32D) Satin stainless steel Accessories •2001-Plug-in Bridge Rectifier •2001-1-Wire-in Bridge Rectifier •2005-Smart-Pac II •2006P-Plug-in Buzzer •152-Universal Mounting Tabs •310-2-3-Astragal •2004-ElectroLynx Connector The term "NorvFail Safo" i.NFS) has been changed lo Fail Secure to conform with ANS1/BHMA standards and definitions. Fail Secure is the standard operation mode for all FAEDC electric strikes and therefore does not require a letter designation when ordering. customer service 800.260.9001 Vision Systems, Inc. Section: 08710 Ventana Real Page 21 of 42 A0605/7-HDW-001 3/12/2007 Grandview Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Section: 08710 Page 22 of 42 3/12/2007 FRAMELESS DOORS .QQQELSlZESj&NDLIfiUEBAtiCES Dam cm ba M>ricaM up to W Mgh Mooning to your apacMcaflona. Doora am manufactured to+1/18- and -W of the MbMl overall alze of trie dooraaa ordered. The mwtneeaetee I*+ 1/32 and-V32-. Waipage Meranca to In according w«h Federal Spacrfcatlont A8TMC 104«. DOOR STYUiS * PREPARATION M.nMn continue* and patch rate can c*deifcnedi«Qand View raib. Thay can ba uaad w conUnuoua raHa only, patch rale only or comMnadone thereof. Doom up to 101 high can ba pfoduoao to your spacHlcanona and ranuTrainanli • Tlia •katchaa ahowm hare Hlwtrato aom* of DM vartoua powtbllHw md Indlctte u prapwtkxi iwturomontSi QLASS-miCKNESS 3«- fllM. h IhnlM to M- IWght glaaa can ba uaad up to W high In an rtandart STANDARD PIVOT DISTANCE 2-5/8'from the edge of Ihadoor to thv ointaV Uno of pivot. Whtn uskiQ wiRdny DMUTI top ptvotv an adJuataMe bearing block la aupplM In our top rail. £1£AR£N£E. Normal factory daaraneae are 1«- at vertical edge* and a total of 6Y1B- In height Differences mutt £QSEJttQB& AH axpoaad adgaa will be polWwd. Flat pollih to a Grand View »tandard. .^Pateh Fittings Pivot Distance 2^/8'Std — ET BP I --- 1" Note Die*HoteDte* Continuous Fittings Preparation Limitations and Hardware Specified Dimension +1/16M/8* n-.—n OTVI ceDOOR STYLES BP A-1 A-2 S-D Outside Inside PtoataSpMtyOoorSwhigbyNuntar ©Copyright 2001 Grand View Glass A Metal, Inc.(877)461-0224 • (909)923-9544 • Fax (909)923-9212 Vision Systems, Inc. Section: 08710 Ventana Real Paae 23 of 42 A0605/7-HDW-001 3/12/2007 GV-150ANDGV-175 RAILS FINISHES: m POLISHED aa •* SATIN 8« U8S POLISHED BRASS PAINTED FINISHES USIOBWITHACLEAR BAKED ENAMEL ANODIZED FINISHES • GV-150 rail receives 3/8" or 1/2" glass in clear, gray or bronze. • GV-175 rail receives 3/4" glass in clear • Both are 1-3/4" x 3-5/16". • Both rails can be modified in height to accommodate specific requirements. Some limitations exist. Consult factory. 1/2" Temp Glass RocWte Cement FULL SCALE DETAILSDIMENSIONS IN INCHES 35/16" 1 15/16' — 3/16"3/16" • 3/4" Temp Glass. ©Copyright 2001 Grand View Glass & Metal, Inc.(877)461-0224 • (909)923-9544 • Fax (909)923-9212 Vision Systems, Inc. Qaotinn- HftTin Ventana Real Dona Oyl f\f A') A0605/7-HDW-001 O M O /O f"\ A7 Ives Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Ca^tinn-na7-in Pane 95 nf 49 3/1?/?nf)7 Floor Stops FS444 Features: • Ideal for interior or exterior use. • Cast brass construction. • Accommodates door undercut up to 2-1/2'. •Non-marring rubber tip. • Packed with expansion shield and lead shield. • Meets ANSI/BHMA 156.16, L12131 for brass, and L32131 for aluminum. • Finishes: US3, US4, US5, US10, US10B, US14, US15, US15A, US26, US26D, US28. Predict No. Overall Height Banulamettr FS444 3' 2-1/2' FS448 Features: • Ideal for interior or exterior use. • Cast brass construction. • Accommodates door undercut up to 2-1/2", • Non-marring rubber tip. • Packed with wood screws. • Meets ANSI/BHMA 156.16, L12121, for brass and L32121 for aluminum. • Finishes: US3, US4, US5, US10, US10B, US14, US15, US15A, US26, US26D, US28. Product No. Overall Height Base Diameter FS448 3" 2-1/2' D6 Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Pemko Hardware Vision Systems, Inc. Ventana Real A0605/7-HDW-001 ^o^ti^r,- Q07in Pano 97 nf 4? 3/12/2007 • To use a saddle threshold in an offset condition, use an titVttM (see page 15). POSITIVE PRESSURE POSITIVE PRESSURE270A 2708 270D 270C POSITIVE PRESSURE271A 271B 271D 271C 271SN 272A 272B 272D 272G 272SN POSITIVE PRESSURE SflSR POSITIVE PRESSURE (6.4) 2750A 2750D 2750G s POSITIVE PRESSURE 800 ' 283-9988 PEMKO MEMPHIS TN goo . 824-3018 Vision Systems, Inc.Ventana Real ED^nd 9ft nf 4^ A0605/7-HDW-001 Rixson Vision Systems, Inc. Ventana Real A0605/7-HDW-001 o«^;««. no-fin Panp9Qnf49 3/12/2QQ7 HEAVY-DUTY 1 SERIES CONCEALED MOUNT - INTERIOR OR EXTERIOR DOORS Product Description & Features « Doors may be single or double acting • Non-handed • Slide track design • Recommended for high traffic, heavy abuse Installations • Heavy shock absorber spring provides 5°-70 compression before dead stop • Surface on/off knob on hold open models « Stop, friction stay or hold open functions • Complete screw packet allows for wood or metal door and frame applications • For security areas, Torx* screws optional • Standard architectural finishes • Non-metal slide block and shock block • 110° maximum opening • 1-3/4" minimum door thickness, for thicker doors, note thickness when ordering • LS option available for doors being used with electromechanical closers & floor closers with dead stop • Track is 1-3/16" tube • UL listed as stop function Door Opening Chart (in inches)Model Number Butts Offset Pivots *24 - 28 28-1/16 - 33 33-1/16-38 38-1/16-43 43-1/16-48 Center Hung Pivots 30-36 36-1/16 - 41 41-1/16-46 46-1/16 - 50 Friction 1-116 1-216 1-316 1-416 1-516 H.O. 1-126 1-226 1-326 1-426 1-526 Stop 1-136 1-236 1-336 1-436 1-536 Shipping Weight .5 ibs. ANSI Friction No. H.O. C01511 Stop C01541 *Butt hung only on this size door. In USA: (800) 457-5670 or www.nxson.com In Canada: (800)461-3007 at »w.v.yal<«r)rbin.ori.ca Vision Systems, Inc.Ventana Real A0605/7-HDW-001 Schlage Vision Systems, Inc. Ventana Real A0605/7-HDW-001 0— i: —. no-nn Dona 11 ^f AO 3/12/2QQ7 Call 1 -800-84 7-5625 CYLINDERS - Rim ,, Vertical Tailpiece (No. 1 bar)Verticil Tailpiece (No. 2 bar) RIM CYLINDERS Description Rim cylinder, vertical tailpiece Rim cylinder, horizontal tailpiece Rim cylinder lockout Cylinder Mechanism Everest or Classic Primus Controlled Access Primus UL437 Everest or Classic Primus Controlled Access Primus UL437 Primus Controlled Access Primus UL437 Complete Cylinders 20-021 20-709 20-509 20-022* 20-710* 20-510* 20-716 20-516 FULL SIZE INTERCHANGEABLE CORE RIM CYLINDERS & HOUSING Description Cylinder with Classic or Everest core Cylinder with Primus* Controlled Access core Housing less core Part No. 20-057* 20-757 20-079 • Use with Von Duprin ait devices. Far Sargent exit do-ices, see Special Cylinders. Notes: 1) Tailpiece orientation may be changed In the field.2) Finishes: 60S, 606, 611, 612,613, 625, and 626. 3) Specify LKB If Primus cylinders ace required less key blanks.4) Lockout keys are not furnished w/cyllnders Sc must be ordered separately. 5) Lockout cylinders will not be master keyed by Schlage. 6) Extended lengths are available for doors over 3" thick. * To order wttti construction core, see Keys and Keying: Full Size Construction Con Program. Notes: 7) Finishes: 60S, 606, 611, 612, 613, 625, and 626. 8) All items Include collar, mounting screws, and backplate. 9) Tailpiece Is horizontal but may be changed to vertical in the field. 10) Control keys are not furnished with cylinders and must beordered separately. 11) Specify 1KB If Primus cylinders are required less key blanks. •v.. SMALL FORMAT INTERCHANGEABLE CORE RIM CYLINDERS & HOUSING Description Rim cylinder, horizontal tailpiece, Everest* restricted keyway Rim cylinder, horizontal tailpiece, construction core Housing only, complete with screws Part No. 80-329 80-159 80-129 Notes 12) Finishes: 605, 606, 611, 612, 613, 625 and 626.13) Control keys are not furnished with cylinders Si must be ordered separately. Operating keys (or construction cores must also be ordered separately.14) Keying must be specified. All Everest keyways are restricted.15) Specify GRIM for green or URN for brown construction core combinations. 16) Locks are assessed a non-refundable handling charge (50-231) per construction core. See Keys & Keying. 17) Tailpiece may be changed to vertical orientation in the field. MOUNTING PLATES & SCREWS, RIM CYLINDER INTERCHANGEABLE CORE RETAINING RING (INCLUDING PRIMUS), RIM CYLINDER Part No. B202-328 B502-200 B502-209 Description Screws and plate pack Mounting plate Mounting screw Part No. 8220-001 B520-361 Description Tailpiece & driver, full size interchangeable core Retaining ring, full size interchangeable core tailpiece TAILPIECES & DRIVERS (Including Primus) RIM Part No. B502-310-604 B502-899 Description Driver Tailpiece, conventional rim cylinder Notes 20) Not compatible with housings manufactured before July 1997. For replacement of older parts, otdn housing less core (20-079). COLLAR, RIM CYLINDER for interchangeable cores only, see Interchangeable Cores Fax: 800-878-6400 • www.seclock.com Part No. B520-153 36-066 Specify Hnish • • Description Collar, conventional cylinder _ Collar, interchangeable core cylinder i JS vj '4 ***. Vision Systems, Inc.Ventana Real Pane 19 nf 49 A0605/7-HDW-001 1/19/9007 {SERIES LEVERS D-SERIES-VANDLGARD Schlage D-Series keyed lever locks with Vandlgard provide vandal resistant technology. Designed for maximum accessibility, security and durability,Vandlgard sets die standard for door hardware in educational facilities and other applications subject to heavy traffic or abuse. The unique features of Vandlgard prevent damage to internal lock components caused by excessive force from persons kicking, hitting or standing on the lever to gain access. Vandlgard functions maintain total key system and architectural design compatibility with Schlage's regular D-Series cylindrical locks. Levers have virtually replaced knobs in the marketplace for handicap accessibility. The added grip and leverage has created an increased opportunity for abuse or vandalism. This abuse often renders locks inoperable. In some cases tiic security oi the door is violated leaving computer and laboratory equipment susceptible to theft. While this type of abuse is commonly associated with junior and senior high schools, it also occurs in universities, office buildings, commercial buildings, and public buildings. Locked lever freely rotates up and down while remain- ing securely locked. The Vandlgard function also increases resistance to over- rotation of the tever. Benefits & Features Superh warranty. All Vandlgard functions have a 7-ycar warranty. Reduce lever wobble and play. Integrated spindle and spring cage greatly reduces lever sag and wobble. Resists vandalism. ["rt'c-whffling lever eliminates the ability to stand or exe rt excessive force on the end of //'£' lever. Ease of installation. Installs in under 2 minutes. Inner spindle operates Independently ol lever when locked D-Series Vandlgard levers comply with ADA requirements. Vision Systems, Inc. Rertinrv 08710 Ventana Real Page 33 of 42 A0605/7-HDW-001 3/12/2007 SERIES LEVERS Functions Non-Keyed Locks SCHLAGE ANSI ND10S F75 Passage Latch Both knobs always unlocked. Exit Lock Outside lever always, fixed. Inside lever alwavs unlocked. Keyed Locks SCHLAGE ANSI ND50PD F82 Entrance/Office Lock* Push-button locking. Push-button locks outside lever until unlocked with key or by turning inside lever. Entrance Lock* 'lurn/push-butron locking; pushing and turning button locks outside lever, requiring use of key until button I* manually unlocked. Push-button locking; pushing button locks outside lever until unlocked by key or by turning inside lever. Electrically Locked (Fail Safe) Outside lever continuously locked electrically. Unlocked by switch or power failure. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. Vestibule/Classroom SecurityLock* Latch retracted by key from outside when outside lever is locked by key in inside lever. Inside lever is always unlocked. Electrically Unlocked (Fail Secure) Outside lever continuously locked unril unlocked by electric current. Auxiliary latch deadlocks latchlx>lr when door is dosed. Inside lever always, tree for immediate exit. Exit Lock Blank plate outside. Inside lever always unlocked. Bath/Bedroom Privacy Lock Push-button locking. Can be opened from outside with small screwdriver. Turning inside lever or closing door releases button. Hospital Privacy Lock Push-button locking. Unlocked from outside by turning emergency turn-button. Turning iuside lever or closing door releases button. Single Dummy Trim Dummy trim for one side ot door. Used for door pull or as matching inactive trim. Store Lock*| Key in either lever locks or unlock* both levers. Classroom Lock* Outside lever locked and unlocked by key. Inside lever always unlocked. Corridor Lock* Outside lever locked by key outside or push-button inside. Push-button released by rotating inside lever or closing door. \('rhen outside lever is locked by key, key must be used to unlock it. Inside lever is always unlocked. * Available Junctions for small format interchangeable core, f Caution: Douhle cylinder locks on residences arid any door in any structure which is used for egress arc a life safety hazard in rimes of emergency and their use is not recommended, Instalhition should he in accordance with existing codes only. Vision Systems, Inc.Ventana Real Pane ^A nf J.9 A0605/7-HDW-001 3/19/9D07 Trimco Vision Systems, Inc. Ventana Real A0605/7-HDW-001 0871D Panp?*inf49 3/1 ?/9nn7 ^Trimco GRIPS TRIMCOtf 1150 1151 OA M CTC CL BHMA 6-1/2"8-1/2" 1/2" Round 1/2" Round 2" 1-1/2"1-1/2" J401 J401 Grip Custom BTB mounting available. ADA Br, Bz, PI, SS TRIMCO# OA M P CTC CL BHMA Grip fOCAL option TRIMCO# OA M P CTC CL BHMA 1191-1 8-3/4" 3/4" Round 2-3/4" 8" 2" J402 is available. ADA 1191-4J 13-1/4" 1-1/4" Round 3-1/4" 12" 2-1/4" J402 1191-2 10-3/4" 3/4" Round 2-3/4" 10" 2" J402 1191-5 18" 1" Round 3-1/4" 18" 2-1/4" J402 1191-3 11" 1 " Round 3-1/4" 10" 2-1/4" J402 1191-5J 19-1/4" 1-1/4" Round 3-1/4" 18" 2-1/4" J402 1191-4 13" 1 " Round 3-1/4" 12" 2-1/4" J402 Br. Bz, PI, SS Grip Offset fOCAL option is available. ADA Br, Bz, PI, SS TRIMCOtf OA M P CTC CL BHMA 1193-1 6" 1/2" X 3/4" Round 2" 5-1/2" 1-1/2" J401 1193-2 8" 1/2"x3/4" 2" 8" 1-1/2" J401 Round Grip Offset fOCAL option is available. ADA Br. Bz, PI, SS Standard Mountings - See Page 3. 24 HOUR FAX: 800-637-8746 CL » clearance, CTC = center-to-center, M = material, OA = overall size, P = projection Vision Systems, Inc.Ventana Real A0605/7-HDW-001 Vision Systems Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Section-O8710 Paae37of42 3/l9/?nn7 Per Shop Drawing Details Vision Systems, Inc. Ventana Real A0605/7-HDW-001 Von Duprin Vision Systems, Inc. Ventana Real A0605/7-HDW-001 QaH-iniv nfl71O Panp "%Q nf 49 3/19/9007 VON DUPRIN. 33A/35A Rim Device 1439 Roller 33A and 3SA lor all types of single and double doors with mullion, UL listed for Panic Exit Hardware. Devices are ANSI A1S6.3 - 2001 Grade 1. The 35A has a smooth mechanism case and the 33A has grooved case. The rim device is non-handed except when the SS (Signal Switch) option is used. See opposite page for available outside trim and device functions. 33A/35A fits door stiles as narrow as 1 %' (44mm). Newly designed device has a one piece center case cover. The 33A/35A devices are available in the following finishes; US3, US4, US10, US26, US26D, US28, 313AN and 31 SAN. See inside cover for finish chips. Specifications Device Lengths Strikes Dogging Feature Dogging Options Electric Options Miscellaneous Options Fasteners & Sex Bolts (SNB) latch Bolt Device Centerllne from Finished Floor Center Case Dimensions Mechanism Case Dimensions Projection 3' 2'4" to 3' (711 mm to 91 4 mm) Door Size 4' 2'10' to 4' (864 mm to 1219 mm) Door Size 1439 -Dull Black Optional Strikes - see page 20 Hex key dogging standard CD Cylinder Dogging, see page 26 LD Less Dogging see page 26 LX Latchbolt Monitor Switch see page 22 RX Pushpad Monitor Switch see page 22 RX2 Double Pushpad Monitor Switch see page 22 SS Signal Switch see page 23 EL Electric Latch Retraction see page 23 ALK Alarm Exit Kit see page 22 PN Pneumatic Latch Retraction see page 26 GBK Glass Bead Kit see page 27 Includes 1 y«" (44mm) - 2 '// (57mm) Wood & Metal Doors 1425 SNB furnished standard for end case #325 SNB furnished standard for EO (exit only device) Deadlocking, %" (19mm) throw 39 W (1011 mm) 39 "/»" (1008 mm) with Mullion 8 Vie" x 2 1%2" x 1 Vw (208mm x 62mm x 40mm) 2 W x 2 1/T (57mm x 57mm) Pushbar Neutral - 3 "As" (97 mm) Pushbar Depressed - 3 W (78 mm) See page 31 for How to Order specification © 2005 Ingersoll-Rand. May be copied for use with specification submittal. Vision Systems, Inc. Spntinrv f)871fl Ventana Real Paap 40 nf 49 A0605/7-HDW-001 3/19/9007 VON DUPRIN. 33A/35A Rim Device Trim Trim Description Exit Only Dummy Trim Pull when Dogged 386DT Night Latch Key RetractsLatchbolt 386NL Night latch Key RetractsLatch boh Optional Pull Required Base Size (190x41mm)(190x41mm) 7'/2"h X (190x43mm) Grip Size (Z1Sx110mm) 8%'h x 4Vi6-» (216x110mm) Projection (62mm)(S2mm)1"(25mm) Cylinder Type Rim Rim Optional Trim (Seepage 19) X360LJ x550 xlVES x550)T DT )T B190 X550DT XIVES819010" Lever Key Locks and Unlocks Lever Blank Escutcheon Always Operable (No Cylinder) J- Thumbtiim Key Locks and Unlocks Thumblurn Always Operable (No Cylinder) ^'wKf-gimngte-twv 35A-T-S Trim Description 360L 360L-BE 360T 360T-BE Base Size (190x43x22mm) 7l4"hx1"/i«wx%"d (190x43x22mm)(190x43x22mm)(190x43x22mm) Grip Size Projection 3(76mm)y(76mm)(46mm)(46mm) ANSI Function Cylinder Type 1'4" Mortise 1V4' Mortise Optional Trim (See page 19) E360L-BE See Page 18 E360T-BE See Page 18 Note: 360L & 360T used on Wood Door require the 33A-WDA cover plate For optional trims and (unctions sea page 19 Vision Systems, Inc. Sprtinrr 08710 Ventana Real 41 of 4? A0605/7-HDW-001 3/19/9007 VON DUPRIN. 33A/35A Options Electrical Accessories Power Supplies SERIES PS873 The series PS873 power supply is designed to operate a wide variety of electrical products. EL panics require 871-2 PCB minimum. The regulated output power is field selectable for either 24VDC @ 2 ampere or 12VDC @ 4 ampere. Standard input 120VAC @ 1.0 ampere or 240VAC & 0.5 ampere available. Enclosure is 10" high x 12X2" wide x 5" deep (254mm x 323mm x 127mm), gray with a hinged cover and constructed of heavy 19 gauge steel. Five 'A" x %" (13mm x 19mm) knockout holes are provided for conduit connection. Terminal block will accept up to 12 gauge wire. The PS873 can be ordered with three standard options: Key lock secures the cover to eliminate tampering and provides safety; Battery backup provides two hours backup power at full load during a A.C. power failure. Batteries will automatically recharge when failed power is restored. Fire Alarm provides input for a normally closed fire alarm contact. When the fire alarm contact is "open", power to locks or other component is removed. Restoring power is field selectable for automatic or manual. Eight standard configurations: PS873 Standard PS873K With keylock PS873B With battery PS873BK With battery and keylock PS873FA With fire alarm PS873K-FA With keylock and fire alarm PS873B-FA With battery and fire alarm PS873BK-FA With battery, keylock and fire alarm The series PS873 is available with several optional circuit cards to provide system flexibility. The power supply will accept one or a combination of any two cards. Factory or Field Installed Circuit Cards: 871-2, Two Zone controller provides two inputs and two outputs. Will operate one or two EL exit devices. Use suffix "-2" for factory installed, example PS873-2. 873-AL, Alarm function monitors 1 or 2 zones and provides alarm output, upon detecting a door in the open position. Delayed alarming is selectable from 5 to 75 seconds. Use suffix "-AL" for factory installed, example PS873-AL 873-AO, Auto Operator function coordinates the release of one or two locks and signals an auto-operator to open a door. Signaling the auto operator can be performed in two methods; by receiving a signal from a monitoring switch that the lock is unlatched, or upon expiration of a time delay triggered by a "RX" type input switch. Use suffix "-AO" for factory installed, example PS873-AO 873-SI, Security/Safety Interlock provide interlock function for two zones. When combined with a second 873-SI card, the Inter-locking of groups are available in two, three or four zones. Safety interlock is available, consult factory for additional information. Use suffix "-SI" for factory installed, example PS873-SI 873-4TD, Four Zone controller with Time Delay provides four inputs and four outputs with time delay. Time delay is field selectable from 0 to 75 seconds, in intervals of 5 seconds. Will operate up to 4 EL devices. Use suffix "-4TD" for factory installed, example PS873-4TD 873-AC, Access Control provides supervision of one zone using an electromagnetic lock. Input signals required are: access control contact, motion detector contact, and motion detector override contact. FA, Fire Alarm option is required. Use suffix "-AC" for factory installed, example PS873-AC Factory Installed Only Circuit Card 873-DE, Delayed Egress provides 15 second delay release from pushbar activation to electro-magnetic lock release. Ideal function for use with Locknetics electromagnetic locks, will operate two zones simultaneously. To operate two separate zones, a second 873-DE card is required. UL listed component, when used as part of a Von Duprin delayed egress system. Use suffix"- DE", example, PS873-DE. Note: "Of" cards CANNOT be combined with any other optional cards. 24 © 2005 Ingersoll-Rand. May be copied for use with specification submittal. Vision Systems, Inc.Ventana Real A0605/7-HDW-001 f\Q~7 A f\ ACORDn CERTIFICATE OF LIABILITY INSURANCE PRODUCER JOHN L. WORTHAM & SON. L.P. P.O. BOX 1388 HOUSTON, TEXAS 77251-1388 080009-73-10 jap - kjones INSURED DAVIS/REED CONSTRUCTION, INC. 12250 EL CAMINO REAL, SUITE 325 SAN DIEGO, CA 92130 I DATE (MM/DD/YY) 06/30/2006 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE . HOLDER. THIS CERTIFICATE DOES NOT AMEND. EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE INSURER A: Illinois National Insurance Co. INSURER B: Travelers Prop. Cas. Co. of America INSURER C: Travelers Indemnity Company INSURER D: INSURER E: COVERAGES THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRLTR B B A C TYPE OF INSURANCE GENERAL DABUTY / COMMERCIAL GENERAL LIABILITY I CLAIMSMADE [7] OCCUR GENT. AGGREGATE UMTT APPLIES PERi r/i PRO- i — i|POUCY|/|PS£ I ILOC AUTOMOBILE LIABILITY ANY AUTO / ALLGWNEOAUTOS SCHEDULED AUTOS / HIRED AUTOS •/ NON-OWNED AUTOS GARAGE LIABILITY ANY AUTO EXCESS LIABILITY _/] OCCUR I I CLAIMS MADE DEDUCTIBLE I RETENTION S WORKERS COMPENSATION AND EMPLOYERS1 LIABILITY OTHER POLICY NUMBER C2JCO5254C325 JCAP54508316 BE5684353 C2KUB4747C539 POLICY EFFECTIVE 06/30/2006 06/30/2006 06/30/2006 06/30/2006 POLICY EXPIRATION 06/30/2007 06/30/2007 06/30/2007 06/30/2007 LIMITS EACH OCCURRENCE FIRE DAMAGE (Any one fir.) MED EXP (Any ana pewm) PERSONAL * ADV INJURY GENERAL AGGREGATE PRODUCTS - COMP/OP AGO COMBINED SINGLE LIMIT(Ea iccld.nl) BODILY INJURY(Par paraon) BODILY INJURY(Par accident) PROPERTY DAMAGE(Per accident) AUTO ONLY • EA ACCIDENT OTVAU1 1ERTH/VI EAACC •0 ONLY: ^g EACH OCCURRENCE AGGREGATE /WCSTATU- OTO-•mRYiiMrrs 1 ER E.L. EACH ACCIDENT E.L DISEASE - EA EMPLOYE! E.L.DISEASE - POLICY LIMIT , 2,000,000 , 300,000 , 5,000 , 2,000,000 , 4,000,000 , 4,000,000 $ 1,000,000 1 $ 1 $ $ $ , 25000000 , 25000000 « t t *, 1,000.000 , 1,000,000 , 1,000.000 DESCRIPTION OF OPERATIONS/LOCATIONSWEHICLES/EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS CONTRACTORS LICENSE NUMBER #81 3480 CERTIFICATE HOLDER ! ADDITIONAL INSURED: INSURER LETTER: CANCELLATION (BELOW & SEE REVERSE) CONTRACTORS STATE LICENSE BOARD PO BOX 28000 SACRAMENTO, CA 95826 I SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 1(5 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE ISSUER, ITS AGENTS OR REPRESENTATIVES. Ay™CRI^RSa^£SENTATlVe"> - , ACORD 25-S (7/97) ff f ©ACORD CORPORATION 1988 r Nl 73mmO 8 7) Q O