HomeMy WebLinkAbout2173 SALK AVE; 250; CB090453; Permit04-21-2009
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB090453
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
Applicant
DESIGNCORP
CHIE HONDA
858-794-3222
2173 SALK AV CBAD St 250
Tl Sub Type
2120210200 Lot#
$571,270 00 Construction Type
Reference #
VENTANAREAL 16.322SF SHELL
TO OFFICE//SPEC SUITE
INDUST
0
5B
Status ISSUED
Applied 03/19/2009
Entered By JMA
Plan Approved 04/21/2009
Issued 04/21/2009
Inspect Area
Plan Check*
Owner
RIO SD PLAZA II MASTER LLC
C/0 NEWPORT NATIONAL CORPORATION
1525 FARADAY AVE #100
CARLSBAD CA 92008
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
Bl D #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
Green Bldg Stands (SB1473) Fee
$2,324 41
$000
$1,51087
$000
$000
$11997
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$2000
Meter Size
Add'l Reel Water Con Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (31 05540)
PFF (4305540)
License Tax (31 041 93)
License Tax (43041 93)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
HMP Fee
TOTAL PERMIT FEES
$000
$0 00
$000
$652 8,8
$10,397 1:1
SO 00
$000
$0 C(0
$19,60000
$000
$56 00
$71000
S181 O'O
$000
$23,658 22
SO CO
$OCO
7? i
$59,230 £6
Total Fees $59,230 56 Total Payments To Date $59,230 56 Balance Due $000
NC.BUILDI
\S IN STO
ATT A
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees'exactions' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you muM
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information'with the City Manager for
processing m accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired '
City of Carlsbad
1635 Faraday Ave . Carlsbad CA 92008
760-602-2717 / 2718 / 2719
Fax 760-602-8558
^Building Permit Application
Plan Check No.
Est. Value
Plan Ck Deposit
lie., ;*,
$-7
JOB ADDRESS
Cf/FR6JECT'5
DESCRIPTION OF WORK
•iSHr~OF UNHS o
SUITE#/SPACE#/'UNIT#
SUITE.
« BATHROOMSo TENANT BUSIMESS NAME
) iM "HXl
CONSTR TYPE
B
Ptic
j CONTACT NAME (If Different Font Applicant)
'"ADDRESS
i PROPERTY OWNER NAME
'^1
DDRESS Greg)/. Cj:., j
[liec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a s gned statement that he is
licensed pursuant to the provisions of the Contractor s License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation of
Section 70! 15 by any applicant for a permit subjects the applicant to a civil penalty of not more than live hundred dollars {$500})
: Workers Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations
i O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued
! ^f I have and will maintain wocke/slrarndfensatioij ajsreauired by Section 3700 of the Labor Code for the performarice olthe worUor whwh thispeymit isjsetjgd My workers compensation irajrance carrierjnd policy
numhorare Insure Co JjWJlM^^ PotoNo//gjfrJ 3fr fl/ffifgS Expiration Da
This section need no! bo completed if the permit is for one hundred dollars ($100) or less
O Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of
California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code interest and attorney's fees ;
J£$ CONTRACTOR SIGNATURE
i D
a
rirm thjt I srn exempt from Contractor s License Lswfor the following reason
I as owner of the property or my employees with wages as their so'e compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for
sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) |
I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s I mcnse Law does not anply to an owner of
property who builds or improves thereon and confar.ts for such projects with conlraclor(s) l-nensed pursuant to the Contractor s License Law) ;
i am exempt under Section _ _ Business and Professions Code for this reason
1 I personally p-'an to provide the major labor and materials for construction of the proposed property improvement Tl Yes D No '
2 I (have.' have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number)
4 I plan to rjrovide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number)
5 I will nrovdf> sot"1 o' thr< work but I hay contracted (hirpd) thr foilnw'nfi nrr^on^ |f> provid" Ihp work Tdrp.lpd (mriiide name / address / phone / type of work) :
^PROPERTY OWNER SIGNATURE DATE
I Is the applicant or future building occupant required to submit a business piar acutely hazardous matena's registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the
1 Presley Tanner Hazardous Substance Account Act7 n Yes w No /
; Is the applicant or future building occupant required to obtain a permit frorrl the air pollution control district or air quality management district9 G Yes pi No ,
Is Ihr; facility to be constructed wilhm 1 000 fePt of the outer boundary of a school site7 G Yes p No /
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT / I
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code)
Lender s Name Lender s Address
••*sw-
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relatm % to building construction
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE C JTY OF CARLSBAD
AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT ,
OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height
180 days from the date of such permit or if the building oc-work authonzejlby sy/fi permit is suspended or abandoned at any time after the work is commenced for a penod of 180 days (Section 10644 Uniform Building Code)
J&£APPLICANT S SIGNATURE DATE
City of Carlsbad
Final Building Inspection
Dept Building Engineering Planning CMWD
Plan Check #
Permit #
Project Name
Address
Contact Person
Sewer Dist
Inspected
By &AJ
Inspected
By
Inspected
By
CB090453
VENTANAREAL 16.322SF SHELL
TO OFFICE//SPEC SUITE
2173SALKAV #250
TOM Phone 8588648412
CA Water Dist CA
.-- Date / ,
75^ / Inspected (O\tO\C
0 Date
Inspected
Date
Inspected
St Lite lyre
Date 06/04/2009
Permit Type Tl
Sub Type INDUST
Lot 0
l^\ Approved t/ Disapproved
Approved Disapproved
Approved Disapproved i
Comments '
City of Carlsbad Bldg Inspection Request
For 06/04/2009
Permit# CB090453
Title VENTANAREAL 16.322SF SHELL
Description TO OFFICE//SPEC SUITE
Inspector Assignment RB
Type Tl Sub Type INDUST
Job Address 2173SALKAV
Suite 250 Lot 0
Location
APPLICANT DESIGNCORP
Owner RIO SD PLAZA II MASTER LLC
Remarks
Phone 8588648412
Inspector
Total Time Requested By TOM
Entered By JANEAN
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Comments
f;
Comments/Notices/Holds
Associated PCRs/CVs
PCR09060 ISSUED VENTANA REAL NI2
Inspection History
Original PC#
W ELECTRICAL, CONTRACTOR/ NO CHANGE TO SCOPE OF W(
Date Description Act Insp
06/01/2009 89 Final Combo PA RB
05/28/2009 84 Rough Combo AP RB
05/27/2009 34 Rough Electric PA RB
05/27/2009 84 Rough Combo CO RB
05/26/2009 34 Rough Electric NR RB
05/22/2009 34 Rough Electric CO RB
05/18/2009 31 Underground/Conduit-Wiring AP RB
05/08/2009 14 Frame/Steel/Bolting/Welding AP RB
05/08/2009 17 Interior Lath/Drywall AP RB
05/06/2009 14 Frame/Steel/Bolting/Welding PA RB
05/06/2009 34 Rough Electric PA RB
05/04/2009 14 Frame/Steel/Bolting/Weldmg AP RB
05/04/2009 17 Interior Lath/Drywall AP RB
Comments
SEE NOTICE ATTACHED
TBAR SYSTEM
FOR METER RELEASE - NEED AS BUILTS APPROVED
ON TBAR - SEE NOTICE
ON CORRECTIONS
SEE NOTICE
walls only completed
completed
PHASE 3 OK
ON CORRECTION PHASE 1
PHASE 1
City of Carlsbad Bldg Inspection Request
For 06/01/2009
Permit# CB090453
Title VENTANAREAL 16.322SF SHELL
Description TO OFFICE//SPEC SUITE
Sub Type INDUST
Inspector Assignment RB
2173 SALK AV
250 Lot
Type Tl
Job Address
Suite
Location
APPLICANT DESIGNCORP
Owner RIO SD PLAZA II MASTER LLC
Remarks
Phone 8588648412
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By TOM
Entered By BARBARA
Act Comment
£<__
Com ments/Notices/Holds
Associated PCRs/CVs Original PC#
PCR09060 ISSUED Vl-NTANA RFAI. NEW IZl.FCTRICAL CONTRACTOR NO CHANGE TO SCOP17 Ol'\V<
Inspection History
Comments
TBAR SYSTEM
FOR METER RELEASE - NEED AS BUILTS APPROVED
ON TBAR-SEE NOTICE
ON CORRECTIONS
SEE NOTICE
walls only completed
completed
PHASE 3 OK
ON CORRECTION PHASE 1
PHASE 1
Date
05/28/2009
05/27/2009
05/27/2009
05/26/2009
05/22/2009
05/18/2009
05/08/2009
05/08/2009
05/06/2009
05/06/2009
05/04/2009
05/01/2009
05/04/2009
Description
84 Rough Combo
34 Rough Electric
84 Rough Combo
34 Rough Electric
34 Rough Electric
31 Undorground/Conduit-Wirmg
1 4 Frame/Steel/Bolting/Welding
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Welding
34 Rough Electric
14 Frame/Steel/Bolting/Welding
17 Interior Lath/Drywall
18 Exterior Lath/Drywall
Act
AP
PA
CO
NR
CO
AP
AP
AP
PA
PA
AP
AP
we
lns|
RB
RB
RB
RB
RB
RB
RB
RB
RB
RB
RB
RB
RB
NOTICECITY OF CARLSBAD (760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
DATE >' ' TIME
LOCATION 3-/7.3-
PERMIT NO
yJTT
s.
••" • 1
FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? i __ YES
FOR FURTHER INFORMATION, CONTACT
PHONE
CODE ENFORCEMENT OFFICER
NOTICECITY OF CARLSBAD (760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
DATE ^ ^ '^(-^/ T|ME
LOCATION__
PERMIT NO
£s-~-T> &**
7
FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? j I YES
FOR FURTHER INFORMATION, CONTACT
CODE ENFORCEMENT OFFICER
City of Carlsbad Bldg Inspection Request
L For 05/22/2009
Permit# CB090453
Title VENT ANA REAL 16.322SF SHELL
Description TO OFFICE//SPEC SUITE
Inspector Assignment RB
Type Tl Sub Type INDUST
Job Address 2173SALKAV
Suite 250 Lot 0
Location
APPLICANT DESIGNCORP
Owner RIO SD PLAZA II MASTER LLC
Remarks ELECTRIC SWITCH GEAR
Phone 8588648412
Inspector
Total Time
CD Description
34 Rough Electric
Act Comments
Requested By TOM
Entered By CHRISTINE
XV» jt ^ /1> H C ^ *
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
PCR09060 PENDING VP.NTANA REAL NEW ELECTRICAL, CONTRACTOR/ NO CHANGP. TO SCOPE OF W(
Inspection History
Comments
walls only completed
completed
PHASE 3 OK
ON CORRECTION PHASE 1
PHASE 1
PHS2
SUB PNL ROUGH IN
MISSING WALL BRACING PER PLAN
PHASE 1 & 2
PHASE 1 & 2 OK
OK TO INSULATE DUCTING @ PHASE 1 ONLY
SEE NOTICE
Date
05/18/2009
05/08/2009
05/08/2009
05/06/2009
05/06/2009
05/04/2009
05/04/2009
05/04/2009
05/04/2009
05/01/2009
05/01/2009
04/23/2009
04/23/2009
04/23/2009
04/23/2009
04/22/2009
04/22/2009
04/22/2009
Description
31
14
17
14
34
14
17
18
34
17
34
14
24
34
44
14
24
34
Underground/Conduit-Wiring
Frame/Steel/Bolting/Weldmg
Interior Lath/Drywall
Frame/Steel/Bolting/Welding
Rough Electric
Frame/Steel/Bolting/Welding
Interior Lath/Drywall
Exterior Lath/Drywall
Rough Electric
Interior Lath/Drywall
Rough Electric
Frame/Steel/Bolting/Weldmg
Rough/Topout
Rough Electric
Rough/Ducts/Dampers
Frame/Steel/Bolting/Welding
Rough/Topout
Rough Electric
Act
AP
AP
AP
PA
PA
AP
AP
we
we
AP
AP
PA
AP
PA
PA
CO
CO
CO
Insp
RB
RB
RB
RB
RB
RB
RB
RB
RB
TP
TP
RB
RB
RB
RB
RB
RB
RB
NOTICE
CITY OF CARLSBAD (760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
DATE -> X^ **- " & 7 TIME.
LOCATION ^/~? 3>
PERMIT NO
FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? L . YES
FOR FURTHER INFORMATION, COWTACT
PHONE
BUILDING INSPECTOR-""7'~ CODE ENFORCEMENT OFFICER
EsGil Corporation
In (partnership with government for <Bui(d~ing Safety
*DATE April 2, 2O09 D APPLICANT
JURISDICTION Carlsbad CJ HLAlTREVlEWER
Q FILE
PLAN CHECK NO O9-453 SET II
PROJECT ADDRESS 2173 Salk Avenue, Suite #250
PROJECT NAME Spec Suite #250
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Chie Honda Telephone # 858 794 3222
Date contacted (by ) Fax# 8587943220
Mail Telephone Fax In Person
REMARKS
By Bryan Zuppiger Enclosures
Esgil Corporation
D GA D MB D EJ D PC 04/01/2009
trnsmtl dot
9320 Chesapeake Drue, Suite 208 4 San Diego, California 92123 * (858)560-1468 * Fax (S58) 560-1576
EsGil Corporation
In Partnersfiip with government for QuiCtting Safety
DATE March 25, 2009 q ....APPLICANTrp"'juRjs^.
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 09-453 SET I
PROJECT ADDRESS 2173 Salk Avenue, Suite #25O
PROJECT NAME Spec Suite #250
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X] The applicant's copy of the check list has been sent to
Chie Honda
444 South Cedros Avenue
Solana Beach, CA 92075
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted,. Chie Honda Telephone # 858 794 3222
Date contactec0/^/0?(by,^45 ) Fax # 8587943220
Mail V Telephone Fax^X In Person
REMARKS
By Bryan Zuppiger Enclosures
Esgi! CorporationD GA n MB n EJ n PC 03/23/2009
trnsmtl dot
9320 Chesapeake Dn\e. Suite 20S * San Diego, California 92123 * (858)560-1468 * l'a\ (S5S) 560-1576
Carlsbad 09-453
March 25, 2009
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 09-453
OCCUPANCY B
TYPE OF CONSTRUCTION HA
SPRINKLERS'? yes
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED March 25, 2009
JURISDICTION Carlsbad
USE office
ACTUAL AREA 16323 ft2
OCCUPANT LOAD unknown
DATE PLANS RECEIVED BY
ESGIL CORPORATION 03/23/2009
PLAN REVIEWER Bryan Zuppiger
This plan review is limited to the technical requirements contained in the International Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review is
based on regulations enforced by the Building Department You may have other corrections based on
laws and ordinances enforced by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to the
issuance of a building permit
Code sections cited are based on the 2007 CBC that adopts the 2006 IBC
The following items listed need clanficatton, modification or change All items must be satisfied before
the plans will be in conformance with the cited codes and regulations Per IBC Section 1054 of the
2006 International Building Code, the approval of the plans does not permit the violation of any state,
county or city law
To speed up the recheck process, please note on this list for a copy) where each correction
item has been addressed, i e , plan sheet number, specification section, etc Be sure to
enclose the marked up list when you submit the revised plans
Carlsbad O9-453
March 25, 2O09
• PLANS
1 Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602 2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
2 Please assign the ceiling details to the reflected ceiling plan
3 Please note that suspended ceilings in Seismic Design Categories D, E & F per ASCE 7-05
Section 135621 shall have the following,
a) A heavy duty T-bar system shall be used
b) The width of the perimeter supporting closure angle shall be no less than 2" In each
orthogonal horizontal direction one end of the ceiling grid shall be attached to the
closure angle The other end in each horizontal direction shall have a %" clearance from
the wall and shall rest upon and be free to slide on a closure angle
c) Note on plan that suspended ceilings shall comply with ASTM C 635 & ASTM C 636
4 The City requires the following notes on the plans
• WIRING METHODS AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is
restricted (without City approval) to one and two family dwellings Note on plans that an
equipment ground conductor is to be installed in all flexible conduits
• The use of flexible metal conduit as a grounding means must comply with City Policy 84-36
• No wiring is permitted on the roof of a building and wiring on the exterior of a building requires
approval by the Building Official City Policy
5 The HVAC unit weight(s) exceed 400lbs an analysis of the existing roof framing from an
engineer or architect licensed by the State of California is required ASCE 1314
Carlsbad 09-453
March 25, 2OO9
The person responsible for their preparation must sign all final sheets of plans (California
Business and Professions Code)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contact Bryan Zuppiger at Esgil Corporation Thank you
Carlsbad 09-453
March 25, 20O9
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO 09-453
PREPARED BY Bryan Zuppiger DATE March 25, 2009
BUILDING ADDRESS 2173 Salk Avenue, Suite #250
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION HA
BUILDING
PORTION
tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
RIHn Pprmit FPP hu OrHina
AREA
(Sq Ft)
16323
cb
Valuation
Multiplier
34 37
By Ordinance
nrp V .
Reg
Mod
VALUE ($)
561,022
561,022
$2,116 95|
Plan Check Fee by Ordinance "* \
Type of Review [Zl Complete Review
[~1 Repetitive Fee
~~i Repeats
D Other
r-j Hourly
EsGil Fee
fj Structural Only
Hr @
$1,37602]
$1,18549]
Comments
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB ^9-
ADDRESS
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $17,000.00)
OTHER
DATE
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER
ENGINEER
DATE
DociMisforms/Pianning Engineering Approvals
D
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
Estimate based on unconfirmed information from applicant
Calculation based onjatfflding plancheck plan submittal
Bldg Permit No
Prepared by ^)/2(/ /O^ Date// ^*-' /
EDU CALCULATIONS^List typfes
Types of Use QJ^f
Types of Use /
APT CALCULATIONS, List types
Types of Use fiJf*^r
Types of Use
FEES REQUIRED
^^ Checked by Date
and square footages for all uses
^ ' ^^*
Sq Ft /Units /£, 3^2 2- EDU's £>.0J
Sq Ft /Units EDU's
and square footages for all uses .*
Sq Ft /Units / 6? .^2^" ADT's "2-T •*
/
Sq Ft /Units ADT's
**
WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO
D 1 PARK-IN-LIEU FEE
FEE/UNIT
PARK AREA & #
X NO UNITS = $
D 2 TRAFFIC IMPACT FEE
ADT's/UNITS
D 3 BRIDGE AND THOROl
ADT's/UNITS
D 4 FACILITIES MANAGE
UNIT/SO FT
D 5 SEWER FEE
EDU's
•2-4*X FEE/ADT
JGHFARE FEE (DIST
X
yiENT FEE ZONE
X
#1 DIST #2
FEE/ADT
FEE/SO FT /UNIT
1 f
DIST #3 )
= $ ^^-^
-*^-
BENEFIT AREA
EDU's
D 6 SEWER LATERAL ($2,500)
D 7 DRAINAGE FEES PLDA_
ACRES
FEE/EDU
X FEE/EDU
HIGH
/Q96
= S
/LOW
FEE/AC = $
D 8 POTABLE WATER FEES
UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION
Word\Docs\Misforms\Fee Calculation Worksheet
Iof2
Rev 7/14/00
X ''
/
c)
IS
o o o
c c c
CL CL CL
D
D D
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No CB09-0453 Address 2173SalkAve
Planner Chris Sexton Phone (760) 602- 4624
APN 212-021-02
Type of Project & Use JJ Net Project Density DU/AC
Zoning P-M General Plan PJ Facilities Management Zone 5
CFD (in/out) #_Date of participation Remaining net dev acres.
Circle One
(For non-residential development Type of land used created by this permit
Legend Item Complete
Environmental Review Required
DATE OF COMPLETION
Item Incomplete - Needs your action
YES D NO D TYPE
Compliance with conditions of approval? If not, state conditions which require action
Conditions of Approval
Discretionary Action Required
APPROVAL/PESO NO DATE
PROJECT NO
OTHER RELATED CASES
YES D NO D TYPE.
Compliance with conditions or approval? If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES D NO Q
CA Coastal Commission Authority? YES Q NO Q
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego, CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Habitat Management Plan
Data Entry Completed? YES D NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE')
Inclusionary Housing Fee required YES D NO D
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
Data Entry Completed? YES D NO D
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE')
H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08
Site Plan1^ n n Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes)
Provide legal description of property and assessor's parcel number
D
Policy 44 - Neighborhood Architectural Design Guidelines
1 Applicability YES D NO Q
2 Project complies YES D NCQ
Zoning
1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope
Required.
Required
Required.
Required
Required
D 2 Accessory structure setbacks
Front
Interior Side
Street Side
Rear
Structure separation
Shown
Shown
Shown
Shown
Shown
Required
Required
Required
Required
Required
Shown
Shown
Shown
Shown
Shown
D D 3 Lot Coverage Required Shown
D D 4 Height Required Shown
D Spaces Required Shown5 Parking
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO °j
H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08
Carlsbad Fire Department
Plan Review Requirements Category TI , TNDUST
Date of Report 04-20-2009
Name
Address
DESIGNCORP
CHIE HONDA
Reviewed by
.j».Permit # CB090453
Job Name VENTANA REAL 16,322SF SHELL
Job Address 2 1 73 SALK AV CBAD St 250
INCOMPLETE The item you have submittedJoMai^^e^^mcomplete At this time, this office cannot
adegB9t5tyTBB3uct a review to deterrrjjjae»egmpiiaric?vli[li Lnfl cl|JUliL'ttbte^«dasLaQd/or standards Please review
carefully all comments attgcjjs^'lfease resubmit the necessary plans and/or specification^, il'llll iJtttu&es "clouded",
to this office for J^diUUand approval
Conditions:
Cond CON0003390
[NOT MET]
1 Sheet E3 0/E3 1 - Review EM lighting The means of egress, including the exit discharge, shall
be illuminated at all times the space served by the means of egress is occupied The means of
egress illumination level shall not be less than 1-foot candle at the walking surface CFC 1006
2 Sheet TI-1 Indicate Fire Extinguisher locations Fire Extinguishers shall be located in
conspicuous locations, readily accessible, and along normal paths of travel CFC 906 and 906 5
3 Specify all door hardware in M O E , not just as "E"
Entry 04/08/2009 By cwong Action CO
Cond CON0003407
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
***Shp Sheet E3 0, E3 1, TI-1 and TI-1 1 PRIOR to pulling permit ****
Entry 04/20/2009 By cwong Action AP
Carlsbad Fire Department
Plan Review Requirements Category Tl, INDUS!
Date of Report 04-08-2009 Reviewed by
Name DESIGNCORP
Address CHIE HONDA
BLDG.DEPTCOPY
Permit # CB090453
Job Name VENTANA REAL 16,322SF SHELL
Job Address 2173 SALK AV CBAD St 250
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards Please review
carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval
Conditions.
Cond CON0003390
[NOT MET]
1 Sheet E3 0/E3 1 - Review EM lighting The means of egress, including the exit discharge, shall
be illuminated at all times the space served by the means of egress is occupied The means of
egress illumination level shall not be less than 1-foot candle at the walking surface CFC 1006
2 Sheet TI-1 Indicate Fire Extinguisher locations Fire Extinguishers shall be located in
conspicuous locations, readily accessible, and along normal paths of travel CFC 906 and 906 5
3 Specify all door hardware in M O E , not just as "E"
Entry 04/08/2009 By cwong Action CO
CONSULTING STRUCTURAL ENGINEERS
3430 Irvine Avenue D Newport Beach, California 92660
(949) 263-1308 FAX (949) 263-1310
STRUCTURAL CALCULATIONS
MECHANICAL UNIT SUPPORTS
PACIFIC BUSINESS CTR
VENT ANA REAL LOT2
2173SALKAVE.
CARLSBAD, CA
ALL SHEETS
March 31, 2009
KLT # 09019
CO N S I! LT I N (j >> T R I' C 1 U R A I. I: N G I N I': I'- R
STRUCTURAL CALCULATIONS
MECHANICAL UNIT SUPPORTS
PACIFIC BUSINESS CTR
VENTANA REAL LOT2
2173SALKAVE.
CARLSBAD, CA
ALL SHEETS
March 31, 2009
KLT#09019
KLT
CONSULTING STRUCTURAL ENGINEERS
3430 hvbM Awwue, Newport Beach, CA 92660
Tel: (949) 263-1308 Fax- (949) 263-1310
PROJECT
SUBJECT
\/£H7AHA 107 Z
///> //
. DATE 3-Zj~ 0? SHEET
CALC BY J7C JOB
OF
LL -
Il
k
K):
y.MJ
-V- - - •---
\
!
V/
1 i
/"tf < g ' -*/,
»•
V 77
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
hlEWPORT'BEACH
CA 92660
TEL (949)263-1308
..FAX £949)263-1310
Composite Steel Beam Design
Uc.«:KW4f004033
Description CHECK (E)FLOOR BEAM W16x26 FOR (N) MECH UNIT WT=441«
Material Properties
Title VENTANA LOT 2 T
Dsgnr
Project Desc
Project Notes
Job « , ?/<•
2
File L WENTANAWentana ec6 »
ENERCALC INC 1983 SOc Ver SC^1 HM,^ \
Calculations per IBC 2006 CEIC 2007 13th AISC
Analysis Method Load Resistance Factor Design
Beam Bracing Beam is Fully Braced against lateral-torsion buckling by attached sla
Load Combination 2006 IBC & ASCE 7-05
Fy Steel Yield 50 0 ksi E Modulus 29,000 0 ksi
Composite Beam Section Data
Total Slab Thickness 6 50 in
Effective Width 40ft
Metal Deck
Ribs Perpendicular
Concrete f c
Concrete Density
Rib Height
Rib Spacing
40 ksi
1450pcf
30 in
120 in
Beam is UNSHORED for Concrete Placement
Stud Diameter 3/4" in
Qn Stud Capacity
Top Width
Btm Width
11 Ok
60m
5 50 m
W16X26
370ft
Applied Loads
Load for Span Number 1
Uniform Load D = 0 9060, L = 0 640 k/fl, Tributary Width = 1 0 ft, Applied after curing
Point Load D = 0 4410 k (5) 18 50 ft, Applied after cunnq
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0 978 1
Section used for this span W16X26
Percent Composite Action 100 %
Construction After Cunng
Mu Applied 00 366 125 k-ft
Mn*Phi Allowable 165750 374 458 k-ft
Service loads entered Load Factors will be applied for calculations
Load Combination After Curing +1 20D+0 50Lr+1 60L+1 60H
Location of maximum on span 18 6242ft
Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward L+Lr+S Deflection 0 972 m
Max Upward L+Lr+S Deflection 0 000 m
Live Load Deflection Ratio 456
Max Downward Total Deflection 0 972 in
Max Upward Total Deflection 0 000 m
Total Deflection Ratio 456
.Shear Stud Requirements .
From Support 1 (5) to 18 62 ft use 35 studs
From 18 62 ft to support 2 use 35 studs
; & Stresses for Load Combinations-..._ _Load Comb & Design Length
Span*
1 4 Di. on StIBm Before Curing
Span L = 37 It 1
1 4 DL on StIBm After Cunng
Span L = 37 ft " 1
After Curing '1 400
Span L- 37 ft 1
After Curing -'1 200+0 SCtr- l 60L-
SpanL = 37ft 1
After Curn« -I .'OC.'-1 ?OU>v r'h
Max Stress Ratios
M" V Ma Const
0976 0,.V?
Maximum Shear Stress Ratio =
Section used for this span
Vu Applied
Vn * Phi Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Bending Summary
MnStl' Phi Ma NonConst MnTr' Phi
165 75 22272 37446
15575 36613 374^6
Desidn OK
0223
W16X26
393218
176625
span 1
00 ft
Span # 1
Shear Summary
Va Vn' Phi
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
NEWPORT BEACH
CA 92660
TEL (949)263-1308
FAX (949)263 1310
Composite Steel Beam Design
Title VENTANA LOT 2 T I
Dsgnr
Project Desc
Project Notes
Job3 i'/t •, /
File L \VENTANA\ventan8 ec6 |
Description CHEOK (E)FLOOR BEAM wi6x26 FOR (N) MECH UNIT wi=44is
Load Comb & Design Length
Span*
"SparTL" = 37 ft " """ "1
After Curing +1 20D-K) 50L+1 60S
Span L = 37 ft 1
Max Stress Ratios
M
0656
0656
V
0149
0149
Ma Const
Bending Summary
MnStl'Phi
T6575
16575
Ma-NonConst
" 245 66
24566
MnTr ' Phi
374 46
37446
Maximum Deflections for Load Combinations • Unfactored Loads
Load Combination
DL on Steel Alone BEFORE Curing
DL on Steel Alone BEFORE Cunng
DL on Steel Alone AFTER Curing
DL on Steel Alone AFTER Curing
After Cunng D after + LH.+S
After Curing D after + Lr+L+S
After Cunng D after + D + Lr + L
After Cunng D after + D + Lr + L
After Cunng D after + D+L+S
After Cunng D after + D +L +S
After Cunng D after + D+L+W
After Curing Dafter + D + L + W
After Cunng D after + D + L + S
After Cunng D after +D + L + S
After Cunng D after + D + L + S
After Curing Dafter + D + L + S
Maximum Vertical Reactions
Load Combination
Overall MAXimum
DL Applied Before Curing
Lr+L+S
(Dbc-Dac) + Lr + L
(Dbc-Dac) + L + S
(Dbc-Dac)*L+W+S/2
(Dbc-Dac)+L+S+W/2
(Dbc-Dac) + L + S + E/1 4
Steel Section Properties
Depth
Web Thick
Flange Width
Flange Thick
Area -
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
• Unfactored
Span
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Location
in Span
370~00
37000
37000
37000
18624
0000
18624
0000
18624
0000
18624
0000
18624
0000
18624
0000
Dead Load Defl
Before Cunng
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
Dead Load Dell
After Curing
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Const Loads
Net Defl
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Support noia'ion ?A< efl is S1
Support 1 Support 2
11840
11840
11840
11840
11840
11840
11840
W16X26
15700 in
0250 in
5500 in
0345 in
7680 in'2
11840
11840
11840
11840
11840
11840
11840
Ixx
Sxx
Rxx
Zx
=
=
=
=
30100
3840
6260
44200
m*4
mA3
in
m*3
lyy
Syy
Ryy
Zy
J
Weight = 26 143 plf
Composite Section Properties
Span Number
Plastic N A Location
Span 1
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Web
PNA in Web
PNA ^ Web
PNA in Wet
PNA in Wet)
PNA in Web
Analysis % Shear
Type Connection... ..
1000
950
900
850
800
750
700
650
600
550
500
450
400
350
300
250
Plastic N A Sum Qn
from Bottom Shear (k).
15700
15665
15630
15595
15560
15525
15491
15456
15421
15386
15265
14497
13729
12961
12193
11425
384 000
364 800
345 600
326 400
307 200
288 000
268 800
249 600
230 400
211200
192000
172800
153600
134400
115200
96000
# Studs per
1/2 Span
35
34
32
30
28
27
25
23
21
20
18
16
14
13
11
9
Mn Capac
k-ft
41606
40942
40253
39541
38805
38045
37261
36454
35623
34769
34322
33538
32619
31558
30349
28984
Ucvnto
Shear Summary
Va Vn' Phi
2630 17663
Non Dead
Load Defl
0000
0000
0000
0000
0972
0000
0972
0000
0972
0000
0972
0000
0972
0000
0972
0000
2630
Total
Deflection
0000
0000
0000
0000
0972
0000
0972
0000
0972
0000
0972
0000
0972
0000
0972
0000
17663
Ixx Used
30100
30100
301 00
301 00
96740
96740
96740
96740
96740
96740
96740
96740
96740
96740
96740
96740
9 590 m»4
3490 in*3
1 120 in
5480 m*3
0262 m"4
Moment o( Inertia
I Sleel I Trans l-Lwr Bound
9674
9561
9437
9299
9147
8980
8796
8594
8371
8127
7858
7563
7237
687 £
6482
604 :.'
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
301 0
12166
1216t
12166
12166
1,2166
12166
1,2166
12166
12166
12166
12166
12166
1 2166
12166
1 2166
1 2166
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
N'EWPORT'BEACH
CA 92660
TEL (949)263-1308
FA_X (949)263-1310
Composite Steel Beam Design
Lie. *: KW-OIOM033Description CHECK (E)FLOOR BEAM wi4x22 FOR (N) MECH UNIT WT=44i#
Material Properties
Analysis Method Load Resistance Factor Design
Beam Bracing Beam is Fully Braced against lateral-torsion buckling by attached sla
Load Combination 2006 IBC & ASCE 7-05
Fy Steel Yield SOOksi E Modulus 29,000 Oksi
Title VENT ANA LOT 2 T
Dsgnr
Project Desc
Job#
Project Notes
File L \VENTANA\ventana ec6
ENERCALC INC 1983 2008
IB L \vtro i AiNAwemana eco m
32008 Ver 6021 H»S- J
HKTJT fiJTif Iffrft M
Calculations per IBC 2006 CBC 2007 13th AISC
Composite Beam Section Data
Total Slab Thickness 6 50 in
Effective Width 4 Oft
Metal Deck
Ribs Perpendicular
Concrete f c
Concrete Density
Rib Height
Rib Spacing
40ksi
1450pd
30 in
120 m
J_
Beam is UNSHORED for Concrete Placement
Stud Diameter 3/4" in
On Stud Capacity 110k
Top Width 60 in
Btm Width 5 50 in
0(0.441)
0(0 902 L(0 64)
W16X26
240ft
Applied Loads
Load for Span Number 1
Uniform Load D = 0 9020, L = 0 640 k/fl, Tributary Width = 1 0 ft, Applied after curing
Point Load D = 0 4410 k (S> 12 0 ft, Applied after cunnq
DESIGN SUMMARY
Maximum Bending Stress Ratio = 04131
Section used for this span W16X26
Percent Composite Action 100%
Constructor) After Curing
Mu Applied 00 154808k-tt
Mn'Phi Allowable 165750 374 458 k-ft
Service loads entered Load Factors will be applied for calculations
Load Combination After Curing +1 20D-K) 50LM 60L+1 60H
Location of maximum on span 11 9195ft
Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward L+Lr+S Deflection
Max Upward L+Lr+S Deflection
Live Load Deflection Ratio
Max Downward Total Deflection
Max Upward Total Deflection
Total Deflection Ratio
0172m
0 000 in
1673
0172m
0 000 in
1673
Shear Stud Requirements
From Support 1 & to 12 72 ft use 35 studs
From 12 72 ft to support 2 use 35 studs
Maximum Forces & Stresses for Load Combinations
Load Comb & Design Length Max Stress Ratios
Span # M V Ma Const
1 4 DL on StIBm Before Curing
Span L = 24 ft 1
1 4 DL on StIBm After Curing
Span L = 24 ft 1
After Curing +1 40D
Span L = 24 ft 1 0 253
After Curing +1 20D-K) 50LM 60!.-
SpanL = 24ft 1 0413
After runriQ •>! ,'<'O^ fi0lr<0rfl'
145
Maximum Shear Stress Ratio =
Section used for this span
Vu Applied
Vn'Phi Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Bending Summary
MnStl' Phi Ma NonConst MnTr' Phi
165"!) 9160 3/446
16575 15461 37446
Design OK
0145
W16X26
25 5414
176625
span 1
00 ft
Span # 1
Shear Summary
Va Vn' Phi
2554 17663
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
'NEWPORT BEACH
CA 92660
TEL (949)263-1308
...EAX_(949)263-.1310
Composite Steel Beam Design
Title VENTANA LOT 2 T I
Dsgnr
Project Desc
Project Notes
Job*
File L \VENTANAWenta.na ec6
EHERCALC INC 1983 200E Vcr SO?1 ''r°' '
\*[SK HIVi'f '* 'i!i?'>VLHIfiffiffis^i^§K^BR^^^ffi^^^^
Description (.-HECK (EjFiOuR BEAM Vv MA,.V FOR iN)
Load Comb & Design Length Max Stress Ratios
SpanS M V
"SpanT="24ft ' 1 " "0 278 ' 0097
After Cunng +1 20D+0 50L+1 60S
Span L = 24 ft 1 0278 0097
awjtjWiaewsys
HttZc&MMK53SaGME&i
MECri UM1 Wl'-441?
Bending Summary
Ma Const MnStl * Phi
16575
16575
Ma NonConst
104 12
10412
MnTr * Phi
37446
37446
SalraSEBSiSalias » r?"*|T if'? iii .*•$.<*
Shear Summary
Va
170E
17 OS
Vn ' Phi
17663
17663
.. Maximum Deflections for Load Combinations • Unfactored Loads
Load Combination Span
DL on'Steel Alone BEFORE Cunng Upward 1
DL on Steel Alone BEFORE Cunng Downward 1
DL on Steel Alone AFTER Curing Upward 1
DL on Steel Alone AFTER Curing Downward 1
After Cunng D after + Lr+L+S Upward 1
After Curing D after + Lr+L+S Downward 1
After Curing D after + D -•• Lr + L Upward 1
After Curing D after + D + Lr + L Downward 1
After Curing D after + D + L + S Upward 1
After Cunng D after + D + L + S Downward 1
After Curing Dafter + D + L+W Upward 1
After Curing D after + D + L + W Downward 1
After Cunng D after + D + L + S Upward 1
After Curing D after + D + L + S Downward 1
After Cunng Dafter + D + L + S Upward 1
After Curing D after + D + L + S Downward 1
Maximum Vertical Reactions • Unfactored
Load Combination Support 1 Support 2
OveralfMAXimum 7680 7680"
DL Applied Before Cunng
Lr+L+S 7 680 7 680
(Dbc-Dac) + Lr + L 7 680 7 680
(Dbc-Dac) +L + S 7680 7680
(Dbc-Dac) + L + W + S/2 7 680 7 680
(DbcDac) + L+S+W/2 7680 7680
(Dbc-Dac) + L + S + E/1 4 7 680 7 680
, Steel Section Properties W16X26
Depth = 15700 in Ixx
Web Thick = 0250 m Sxx
Flange Width = 5500 in Rxx
Flange Thick = 0345 in Zx
Area = 7680 m'2
Weight = 26143 plf
Composite Section Properties
Span Number Analysis % Shear
Plastic N A Location Type Connection
Span 1
PNA in Flange 100 0
PNA in Flange 95 0
PNA in Flange 90 0
PNA in Flange 85 0
PNA in Flange 80 0
PNA in Flange 75 0
PNA in Flange 70 0
PNA in Flange 65 0
PNA in Flange 60 0
PNA in Flange 55 0
PNA in Web 50 0
PNA in Web 45 0
PNA in Web 40 0
PNA in Web 35 0
PNA in Web 30 0
PNA m Web 25 0
Location
in Span
24000"
24000
24000
24000
12081
0000
12081
0000
12081
0000
12081
0000
12081
0000
12081
0000
Dead Load Defl
Before Cunng
" OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
OOOOO
Dead Load Defl
After Cunng
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Const Loads
Net Defl
"6" 000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Non-Dead Total
Load Defl Deflection
0 666 0 000
0 000 0 000
0 000 o 000
0 000 0 000
0172 0172
0 000 0 000
0172 0172
0 000 0 000
0172 0172
0 000 0 000
0172 0172
0 000 0 000
0172 0172
0 000 0 000
0172 0172
0 000 0 000
Ixx Used
301 00
30100
30100
30100
96740
96740
96740
96740
96740
96740
96740
96740
96740
96740
96740
96740
Support nolaiion Far ieft is s1
=
=
=
=
Plastic N A
301 00
3840
6260
44200
SumQn
from Bottom Shear (k)
15700
15665
15630
15595
15560
15525
15491
15456
15421
15386
15265
14497
13729
12961
12193
11425
384 000
364 800
345 600
326 400
307 200
288 000
268 800
249 600
230 400
211200
192 000
172800
153600
134 400
115200
96000
in*4
in*3
in
in"3
# Studs per
1/2 Span
35
34
32
30
28
27
25
23
21
20
18
16
14
13
11
9
lyy
Syy
Ryy
Zy
J
Mn Capacity
kft
41606
40942
40253
39541
38805
38045
37261
36454
35623
34769
34322
33538
32619
31558
30349
28984
9590 inA4
3490 inA3
1 120 in
5480 mA3
0262 mM
Moment of Inertia
I Steel I Trans
3010 1,2165
3010 1216 o
3010 12166
301 0 1 216 b
3010 1,216 ()
3010 12166
3010 1,2166
3010 12166
3010 12166
3010 12166
3010 12166
3010 12166
3010 12166
3010 12166
3010 12166
3010 1,2166
I Lwr Bound
9674
9561
9437
9299
9147
8980
8796
8594
8371
8127
785 &
7563
723 7
6878
648 ?
604 5
KLT
CONSULTING STRUCTURAL ENGINEERS
3430 Irvine Avenue, Newport Beach, CA 92660
Tel (949)263-1308 Fax. (949) 263-1310
PROJECT \/eMTAHA
SUBJECT
DATE
CALC BY
SHEET
JOB
OF
).'i >
=Js > 7 - ,v-j- ?
p >z
i*
L-
2.~7/
//
.v 3 '
(t)
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
"NEWPORY BEACH
CA 92660
TEL (949)263-1308
FAX (949)263-1310
Composite Steel Beam Design
Lie. #' KW-06004033
Description CHECK (E)FLOOR BEAM W27x84 FOR (N) MECH UNIT LOADS
Material Properties _
Title VENTANA LOT 2 T I
Dsgnr
Project Desc
Project Notes
Job*
File I \VENTANA\ventanaec6
ENERCALC.INC 1963-2008 Vet 6021 NM^.
L'OLfctnt* Owner:
Calculations per IBC 2006 CBC 2007 13th AISC
Analysis Method Load Resistance Factor Design
Beam Bracing Beam is Fully Braced against lateral-torsion buckling by attached sla
Load Combination 2006 IBC & ASCE 7-05
Fy Steel Yield 500ksi E Modulus 29,0000ksi
Composite Beam Section Data Beam is UNSHORED for Concrete Placement
ital Slab
fecbveV
etalDec
bs
T,.. .,-,,.
Thickness 6 50 in
Vidth 40ft
k
Parallel
„, „,„., ,- T
Concrete f c 4 0 ksi
Concrete Density 1 45 0 pel
Rib Height 30 in
Rib Spacing 120 in
D(0
DO 714
1
882)
L(264)
Stud Diameter
Qn Stud Capacity
Top Width
Btm Width
•was? -•"- eetx-.~~*y-~T*'-» JM.U "P!U.'l'li'&:V»*i^J!T>3»lF'!iffe*r^i»wt
3/4" m
11 Ok
60m
5 50 in
n."»(tnr7V -™J
W27X84
320ft
Service loads entered Load Factors will be applied for calculations
Load for Span Number 1
Uniform Load D = 3 7140. L = 2 640 k/ft, Tnbutary Width = 10 ft, Applied after cunnq
Point Load D = 0 8820 k & 16 0 ft, Applied after cunnq
Maximum Bending Stress Ratio =
Section used for this span
Percent Composite Action
Construction
Mu Applied 00
Mn'Phi Allowable 9150
0771 1
W27X84
100 %
After Curing
1,119 50 k-ft
1,452 87 k-ft
Load Combination After Curing +1 200*0 50LM 60L+1 60H
Location of maximum on span 15 8926ft
Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward L+Lr+S Deflection
Max Upward L+Lr+S Deflection
Live Load Deflection Ratio
Max Downward Total Deflection
Max Upward Total Deflection
Total Deflection Ratio
0 374 in
0 000 in
1026
0 374 in
0 000 in
1026
Shear Stud Requirements
From Support 1 @ to 16 11 ft use 74 studs
From 1611 ft to support 2 use 74 studs
Maximum Forces & Stresses for Load Combinations
Load Comb & Design length Max Stress Ratios
Span* M V Ma-Const
1 4 DL on StIBm Before Curing
1 4 DL on StIBm After Curing
Span L = 32 ft 1
After Curing +1 400
Span L = 32 ft 1
After Curing *1 20D*0 50LM 60L"
0465
0771
0152
0252
Maximum Shear Stress Ratio =
Section used for this span
Vu Applied
Vn'Phi Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Bending Summary
MnStl * Phi Ma NonConst MnTr • Phi
91500 67533 145287
91500 111950 145287
Design OK
0252 1
W27X84
139422 k
552690 k
span 1
00 ft
Span # 1
Shear Summary
Va Vn' Phi
83 61 552 69
13942 55269
After Curing *1 ?OD*1 GOLr-K) SOL
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
NEWPORT BEACH
CA 92660
TEL (949)263-1308
FAX. (949)263-1310
Composite Steel Beam Design
Title VENTANA LOT 2 T
Dsgnr
Project Desc
Project Notes
File L WENTANAWentana ec6 •
ENERCALC INC 19832008 V<r 0021 t-!!JW f
Description CHECK (EjFlOOR BEAM W27xB4 FOR (N) MECH UNIT LOADS
Load Comb & Design Length
Span*
"Span 1 = 32 ft " " 1 "
After Curing +1 20D+0 50L+1 60S
Span L = 32 ft 1
Max Stress Ratios
M V
0515 0168
Ma Const
Bending Summary
MnSti * Phi Ma-NonConst
"9i5"b"0" "74781
0515 0168 91500 74781
MnTr * Phi
145287 "
145287
Shear Summary
Va Vn' Phi
92 96 552 69
9296 55269
Maximum Deflections for Load Combinations • Unfactpred Loads
Location Dead Load Defl Dead Load Defl
Load Combination
DL on Steel Alone BEFORE Curing
DL on Steel Algne BEFORE Cunng
DL on Steel Alone AFTER Curing
DL on Steel Alone AFTER Curing
After Curing D after + Lr+L+S
After Cunng D after + Lr+l+S
After Cunng D after + D + U + L
After Curing D after * D + Lr + L
After Cunng Dafter + D + L + S
After Cunng D after + D + L + S
After Curing D after + D + L+W
After Cunng D after + D + L + W
After Cunng D after + D + L + S
After Curing D after + D + L + S
After Cunng D after + D + L + S
After Curing D after + D + L + S
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Span
'1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
in Span Before Cunng
" 32000
32000
32000
32000
16107
0000
16107
0000
16107
0000
16107
0000
16107
0000
16107
0000
Maximum Vertical Reactions • Unfactored
Load Combination
OveralfMAXimum
DL Applied Before Cunng
Lr+L+S
(Dbc-Dac)+Lr + L
(Dbc-Dac) + L + S
(Dbc-Dac) +L+W + S/2
(Dbc-Dac) + L + S + W/2
(Dbc-Dac) + L + S + E/1 4
Steel Section Properties
Depth =
Web Thick
Flange Width
Flange Thick =
Area =
Weight
0 0000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
ciipjiort notation
After Cunng
"0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
fvr eit si
Const Loads Non-Dead Total
Net Defl Load Defl Deflection
o'ooo
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0374
0000
0374
0000
0374
0000
0374
0000
0374
0000
0374
0000
0000
0000
0000
0000
0374
0000
0374
0000
0374
0000
0 374
0000
0374
0000
0374
0000
Ixx Used
2 850 00
2 850 00
2 850 00
2 850 00
580106
5 801 06
580106
5 801 06
5 801 06
5,801 06
5 801 06
5801 06
580106
580106
5 801 06
5,801 06
Support 1 Support 2
42 240
42240
42240
42240
42240
42240
42240
W27X84
26700 in
0460 in
10000 in
0640 in
24800 mA2
84419 plf
42240
42240
42240
42240
42240
42240
42240
I XX
Sxx
Rxx
Zx
-
=
=
=
2 850 00 in
21300 in
10700 in
244 000 in
M
A3
A3
lyy
Syy
Ryy
Zy
J
106000
21200
2070
33200
2810
m*4
in"3
in
m"3
inM
Composite Section Properties
Span Number
Plastic N A Location
Span 1 "~
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA m Web
PNA in Web
Analysis % Shear
Type Connection'
1000
950
900
850
800
750
700
650
600
550
500
450
400
350
300
250
Plasbc N A
from Bottom
26266
26226
26185
26145
26105
26064
25279
24403
23527
22651
21775
20899
20023
19148
18272
17396
Sum On
Shear (k)
.
805 800
765 510
725 220
684 930
644 640
604 350
564 060
523 770
483 480
443 190
402 900
362610
322 320
282 030
241 740
201 450
# Studs per
1/2 Span
"
74
70
66
63
59
55
52
48
44
41
37
33
30
26
22
19
Mn Capacity
ktt
1 614 30
1,60752
1,59978
1 591 10
1 581 47
1 570 90
1 590 55
1 581 63
1 569 10
1,55285
1 532 79
1 508 79
148074
1 44849
1 411 89
1 370 77
Moment of inertia
l-Steel
28500
28500
28500
2,8500
28500
28500
28500
28500
28500
2,8500
28500
28500
28500
28500
28500
28500
I Trans
69247
69247
69247
69247
69247
69247
69247
69247
6 924 7
69247
69247
69247
69247
69247
69247
6 924 7
l-Lwr Bound
5801 1
5,750 6
56940
56307
55604
5 482 5
53964
53016
51974
50830
4 957 6
48204
46704
4 506 £
4 327 5
4 13? 1
KLT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
•NEWPORT BEACH
CA 92660
TEL (949)263-1308
--(LAX (949)263-1310
Composite Steel Beam Design
Lie. » : KW-06004033
Description CHECK (E)FLOOR BEAM W24x68 FOR (N) MECH UNIT LOADS
Material Properties
Analysis Method Load Resistance Factor Design
Beam Bracing Beam is Fully Braced against lateral-torsion buckling by attached sla
Load Combination 2006 IBC & ASCE 7-05
Fy Steel Yield SOOksi E Modulus 29,000 Oks:
Composite Beam Section Data
Total Slab Thickness
Effective Width
Metal Deck
Ribs Pi
Title VENTANA LOT 2 T I
Dsgnr
Project Desc
job #0/<:•/•/
Project Notes
File L \VENTANA\ventanaec6
ENERCALC INC 1983-2008 Ver 6021 K W A
UctnM Own*r: KL
Calculations per IBC 2006. CBC 2007 13th AISC
t
j.
Beam is UNSHORED for Concrete Placement
6 50 in
40ft
•allel
t
Concrete f c
Concrete Density
Rib Height
Rib Spacing
D(271]j
40ksi
1450pcf
30 in
120 in
323)
L(1 92)1
Stud Diameter
On Stud Capacity
Top Width
Btm Width
3/4" m
11 Ok
60 in
5 50 in
vf«q....«ntM ,,...-»_.•*.«,.. ....
-^•- .A.,.»_J.-J.I:I...^-JJT!
W27X84
330ft
Applied Loads Service loads entered Load Factors will be applied for calculations
Load for Span Number 1
Uniform Load D = 2 710, L = 1 920 k/ft, Tnbutary Width = 1 0 ft, Applied after cunnq
Point Load D = 1 3230 k & 16 50 ft, Applied after cunnq
Maximum Bending Stress Ratio -
Section used for this span
Percent Composite Action
Construction
Mu Applied 00
Mn*Phi Allowable 9150
0601 1
W27X84
100%
After Curing
873 826 k-ft
1,452 87 k-ft
Load Combination After Curing +1 20D-*0 50Lr+1 60Lf1 60H
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward L+Lr+S Deflection
Max Upward L+Lr+S Deflection
Live Load Deflection Ratio
Max Downward Total Deflection
Max Upward Total Deflection
Total Deflection Ratio
16 3893ft
Span # 1
0 308 in
0 000 in
1286
0 308 in
0 000 in
1286
Shear?Stud Requirements
From Support 1 @ to 16 83 ft use 74 studs
From 16 83 ft to support 2 use 74 studs
Maximum Forces & Stresses for Load Combinations
Load Comb & Design Length ' Max Stress Ratios
Span* M V Ma Const
1 4 DL on StiBm Before Curing
Span L = 33 ft 1
1 4 DL on StlBm After Curing
Span L = 33 ft 1
Atler Curing +1 40D
Span L = 33 ft 1 0366 0115
After Curing »1 20D+0 50Lr-1 60L*
Span L = 33 ft 1 0601 0190
After Curing -1 ?OD+1 GOLf^fl 50L
Maximum Shear Stress Ratio =
Section used for this span
Vu Applied
Vn'Phi Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Bending Summary
MnStl * Phi Ma-NonConst MnTr * Phi
91500 53161 145287
91500 87383 145287
Desiqn OK
0190 1
W27X84
105140 k
552690 k
spanl
330 ft
Span # 1
Shear Summary
Va Vn' Phi
63 53 552 69
10514 55269
KIT CONSULTING STRUCTURAL ENGINEERS
3430 IRVINE AVE
'NEWPORT BEACH
CA 92660
TEL (949)263-1308
FAX (949)263-1310
Composite Steel Beam Design
Title VENTANA LOT 2 I
Dsgnr
Project Desc
Project Notes
Jobfi .,-•'/ : I
File L \VEHTANA\ventana ec6
ENERCALC INC 198'< 2006 vet 0021 NcJ?r-.-
Description CHECK lEjFLOOR BEAM W24x68 FOR (N) MECH UNiT LOADS
Load Comb & Design Length Max Stress Ratios
Span# M V Ma Const
~SpanI = 33ft ' 1 0404 0127
After Curing +1 20D-0 50L+1 60S
Span L = 33 ft 1 0404 0127 91500
Maximum Deflections for Load Combinations • Unfactored Loads
Bending Summary
MnStl 'Phi Ma-NonConst
"91500 "" 58634
58634
Location Dead Load Defl Dead Load Defl
Load Combination
DL on Steel Alone BEFORE Curing
DL on Steel Alone BEFORE Cunng
DL on Steel Alone AFTER Curing
DL on Steel Alone AFTER Curing
After Curing D after + Lr+L+S
After Cunng D after + Lr+L+S
After Curing D after + D + Lr + L
After Curing D after + D + Lr + L
After Curing D after + 0 + L + S
After Curing D after + D + L + S
After Curing D after +D+L+W
After Cunng D after + D + L + W
After Cunng D after + D + L + S
After Curing D after + D + L + S
After Curing D after + D + L + S
After Curing D after + D + L + S
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Upward
Downward
Span
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Maximum Vertical Reactions • Unfactored
Load Combination
Overall MAXifnum
DL Applied Before Curing
Lr+L+S
(Dbc Dae) + Lr + L
(DbcDacJ + L+S
(Dbc-Dac) + L + W+S/2
(Dbc-Dac) + L + S + W/2
(Dbc-Dac) + L+S + E/14
Steel Section Properties
Depth
Web Thick
Flange Width
Flange Thick =
Area =
Weight
in Span Before Cunng After Cunng
" 33000'
33000
33000
33000
16611
0000
16611
0000
16611
0000
16611
0000
16611
0000
16611
0000
S,
"boooo
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
00000
.ipport notation <:
booo
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
ctr en s *1
Support 1 Support 2
31680
31680
31680
31680
31680
31680
31680
W27X84
26700 in
0460 in
10000 in
0640 in
24800 m"2
84419 plf
31680
31680
31680
31680
31680
31680
31680
Ixx
Sxx
Rxx
Zx
=
=
=
=
2,85000 inA4
21300 m"3
10700 in
244 000 m"3
Composite Section Properties
Span Number
Plastic N A Location
Span 1
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Flange
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA in Web
PNA m Web
PNA in Web
Analysis % Shear
Type Connection
1000
950
900
850
800
750
700
650
600
550
500
450
400
350
300
250
Plastic N A
from Bottom
26266
26226
26185
26145
26105
26064
25279
24403
23527
22651
21775
20899
20023
19148
18272
17396
Sum On
Shear (k)
805 800
765510
725 220
684 930
644 640
604 350
564 060
523 770
483 480
443 190
402 900
362610
322 320
282 030
241 740
201 450
# Studs per
1/2 Span
74
70
66
63
59
55
52
48
44
41
37
33
30
26
22
19
MnTr * Phi
"1,45287
1 452 87
Const Loads
Net Defl
6 bob"
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Sheai Summary
Va Vn' Phi
70 29 552 69
Non-Dead
Load Defl
0 000
0000
0000
0000
0308
0000
0308
0000
0308
0000
0308
0000
0308
0000
0308
0000
iyy
Syy
Ryy
Zy
J
Mn Capacity
k-ft
161430
1,60752
1 599 78
1,591 10
1 581 47
1 570 90
1 590 55
1,581 63
1 569 10
1,55285
153279
1 508 79
148074
1448 49
1 411 89
1 370 77
7029
Total
Deflection
" 0 000
0000
0000
0000
0308
0000
0 308
0000
0308
0000
0308
0000
0308
0000
0308
0000
106000 in*4
21 200 m*3
2070 in
33200 m*3
2810 inM
55269
Ixx Used
2,850 00
2 850 00
2 850 00
2 850 00
580106
5 801 06
580106
5,801 06
5 801 06
5 801 06
5.801 06
5,801 06
5 801 06
580106
5 801 06
5 801 06
I Steel
Moment of Inertia
I Trans I Lwi Bound
2,8500
28500
28500
28500
28500
2,850 0
28500
28500
2,850 0
28500
2,8500
28500
28500
28500
28500
28500
69247
69247
69247
6924 7
69247
6924 7
6924'
6924 '
6,924 ,'
6 924 ,'
6 924 ,'
6 924 /
6 924 ,'
6 924 /
6924 ,
69247
5801 1
57506
56940
56307
55604
54825
53964
53016
51974
5.083 0
4957s
4820*
4670"
4 506 S
43?7 C>
4 12? 1
KLT
CONSULTING STRUCTURAL ENGINEERS
3430 Irvine Avenue, Newport Beach, CA 92660
Tel (949)263-1308 Fax (949)263-1310
PROJECT
SUBJECT
TX1M/1 71 ,
///;/*/?/>/ UHlJ f
DATE 3>"g/-.;V SHEET OF
CALC BY JC JOB
A\-
t!
Iico
o:
1
§i
K-s
o
,£
CD
O
I
I
n
O
CN
£
<
i- <
UJ>
2 .£ v
'° ii
UJI
eno\
i-o\r~>o
CN
o
uj 2
O LJ
ii' Eo
Mi"<"^N
o ^
II- Z
,=1 -!o S
APR-OT-2009 TUE 04:23 PH CITY OF CARSLBAD'IN TI.»«, ,.ivi-n ' frill"."!".
FAX NO" 760 .-602 8558 P. 03
'•• -v •• - -
rjn; ;CIPJ ":'. - r'
NON-RESIDENTIAL CERTIFICATE: NON-RESIDENTIAL LAND OWNER. PLEASE
READ THIS OPTION CAREFULLY AND BE SURE YOU THOROUGHLY-UNDERSTAND
BEFORE SIGNING THE OPTION YOU CHOSE WILL AFFECrYOUR PAYMENT "OF THE
DEVELOPED SPECIAL TAX ASSESSED ON ""YOUR "PROPERTY."'THIS"* OPTION IS
AVAILABLE ONLY AT THE TIME OF THE FIRST BUILDING PERMIT ISSUANCE
PROPERTY-OWNER SIGNATURE-IS REQUIRED-BEFORE-SIGNING 'YOUR SIGNATURE IS
CONFIRMING THE ACCURACY OF ALL INFORMATION SHOWN. "' *" '
VENTANA REAL MASTER LLC
NAME OF OWNER
1525 FARADAY AV STTEIOO
ADDRESS
760 6O7*S282
CARLSBAD CA 92008
CITY, STATE
212-02!-02>00
ZIP
TELEPHONE
21738ALKAV STE25O
PROJECT ADDRESS
CARLSBAD CA
CITY, STATE J «•• . ZIP
ASSESSOR PARCEL NUMBER(S) OR APNfe) AND LOT NUMBERS^) IF NOT YET SUBDIVIDED BY COUNTY ASSESSOR
CBO90453 ' "• -- '" '" ' ..
BUILDING PERMIT NUMBER(S) , ..,
As CITED BY ORDINANCE No NS-155 AND ADOPTED BY THE CITY" OF "(
THE CITY IS AUTHORIZED TO LEVY A SPECIAL" TAX IN COMMUNITY FACILITIES DISTRICT'NO. 1. ALL
NON-RESIDENTIAL-PROPERTY, UPON THE ISSUANCE OF A BUILDING;<PERMITi.jSHALU. HAVE THE
OPTION TO (1) PAY THE SPECIAL DEVELOPMENT TAX ONE -TIME' ORV^S) "ASSUME THE
ANNUAL SPECIAL TAX - DEVELOPED, PROPERTY FOR A PERIOD NOT TO EXCEED (TWENTY-
FIVE (25) YEARS. PLEASE INDICATE YOUR CHOICE &Y INITIALIZING THE APPROPRIATE ur^e BELOW.
OPTION (1 >. I ELECTTO PAYTHE SPECIALTAX« ONE TIME NOW,'AS A ONE-TIME PAYMENT.
AMOUNT OF ONE-7f»fl=; SPECIAL TAX: $ $652.88;
OWNER'S INITIALS .
OPTION (2) '' ' I ELECT TO PAY THE SPECIAL DEVELOPMENT TAX ANNUALLY FOR A
PERIOD NOT TO EXCEED TWENTY-FIVE (25) YEARS „;".,".. -£^1 -^"-^' .
;.---.- - " MAXIMUM ANNUAL SPECIAL TAX: $:~ J" -*-.«=•--"-
OWNER'S INITIALS .i •—' ,, V ( ^* »^ ~' *» -i 3^5 i *^*
DO HEREBY CERTIFY UNDER PENALTY OF PERJURY THAT THE UNDERSIGNED IS
THE PROPERTY OWNER OF THE SUBJECT'PROPERTY AND THAT I UNDERSTAND
""'" '' -L CC2&HPLY WITH THE PROVISION AS STATED ABOVE - X~i - -
. our i
- TITLE
PRINT NAME DATE'1
THE Crrr OF CARLSBAD HAS NOT INDEPENDENTLY VERIFIED THE INFORMATION SHOWN'ABOVE.-THEREFORE,
WE ACCEPT NO RESPONSIBILITY AS TO THE ACCURACY QH'COMPLETENESS qf^THlS INFORMATION.^. Co '
! ,"' .7 •^'-- • ."T Rl«»"i <f ' ' '- .^ .- .
LAND USE INDUST .IMP. AREA 1 _. ;.y = . FY B/7/B'it-! - V1 ' .. * i , ••, .. • j,)' / vVJjSff ix- i-'
FACTOR SHELL,=a.8OO7-.7S86a.O4 X SQUARE FT/,1 6,322 -;=/-$ QS2.88. •-
APR i2-2006 WED 07:12 All CITY OF CA
* (
"onmiumty Faciliti-
NON-RESIDENTIAL CERTIFICATE: Non-Residential Land Owner,
please read this option carefully and be sure you thoroughly understand the options before
signing. The option you chase will affect your payment of the developed Special Tax
assessed on your property, this option is available only at the time of the first building
permit issuance. Property owner signature is required before & building permit will be
issued. Your signature is confirming the accuracy of all information shown.
3T ^irfr
Name of Owner Telephone
Address
CAJ\$\)IS
City, State
/ !
CA W^^V
Zip Code
1[i. &LO '
Project Address
Carlsbad, California
City, State
2^1 00
9200^
Zip Code
Assessor's Paree] Number or APN and Lot Number if not yet subdivided by County Attestor.
C6 QG • "LH
Building Permit Numbers)
As cited by Ordinance No NS-155 and adopted by the City of Carlsbad, California, the City a authorized
to levy a Special Tax in Community Facilities District No I. All non-residential property, upon die
issuance of a building permit, shall nave the option to (1) pay the SPECIAL DEVELOPMENT TAX ONE-
TIME or (2) assume the ANNUAL SPECIAL TAX - DEVELOPED PROPERTY for a period not to
exceed twenty-five (22) years Please indicate your choice by initialing the appropriate lute below:
OPTION (1).
OPTION (2)
I elect to pay the SPECIAL TAX - ONE-TIME n^w, as a one-tone payment Amount of
One-Time Special Tax- S to 2-. O^S> • Owner's Initial*
1 elect to pay the SPECIAL DEVELOPMENT TAX ANNUALLY for a period not to
exceed Jjwenty-five, ^ (25) years Maximum Annual /^Special Tax-
S M; S6Y. Owner's Initials, /I/fa/.
\ DO HEREBY CERTIFY UNDER PENALTY OP PERJURY THAT THE UNDERSIGNED IS THE
PBOPCRTV OWNTK HF TTTP flimmnT VnCirmTV AWn THAT I UNDERSTAND AND WTLI.
COMPLViVITH THE PROVISIONS AS STATED ABOVE
Title
DatePrint Name
The City of Carlsbad has nut independently verified the information shown above Therefore, we accept no
responsibility as to the accuracy or completeness of this information
Land Use, FY .Faclor &ug> QrY *]{ /O^fAf, #/Square Ft
i(71WN>ros
i:'1"* (
*t "f
's:-I-rtv
r
V
...; -,-a
• . ^^\\
^ u
-'~~^
^
JM
no
•o
ftI•p.
2 Z
-C
SDo
0
O
§>
(T)
D§
m
D
Do
m
i
&o
n>
?st
jijP*Si
?
^
^§
n>Need?Tl~^n>
r4-
^•M
OQ
0Jb•*S Engineer!3UD
I ***.•V, t
PlanningCO
5.
ID
>4
fc
^Q:&Comme3cr
&»
D01
f?
O01
re
io
-<
2
-<
,2 Stormwa;n•%
•<
z
V/1
-i
•<
Z
l/in
OO
c
i
X
1
•<'
Z
'
*
TJm
f?i
2
JL.
-v.
51>^
3i
z
|T
TJTl
Tl
^
«!
(V"*4J
N<
z
i?^-
§
^^
£N-^
z
>
^
mai
3
•<
z
O)N
<
I
fD
Si.
5
-<
Z
Tl
O0
•<
z
Tl
3
;
nTlD
JT
^->!
iForms/•nf»nM
IS!?ZJr*
.S5.
"i»i
-<i
-^
O
^
^
S3
«n
a
p
N*>" h.
*| f1 ,
^vra
S
mO)
5
>TJnD 1 HazMatTlo
Oi
}
<
Tls
*k?y
3tv-A?
^B\x
m
10
s2
id
^^-o
^c1)t
TJ
0)
g
IQ
Iv\_a;
\
F^
CO
a
1
^\xr*
^**%s^
~0
•^
^
>tJXI
5<
&
D.&>*+fO
s_?D
5
05-29-2009
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR09060
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Reference #
PC#
Project Title
Applicant
CHRIS SASS
619-456-4500
2173 SALK AV CBAD St 250
PCR
2120210200 Lot#
$0 00 Construction Type
CB090453
0
NEW
VENTANA REAL NEW ELECTRICAL
CONTRACTOR/ NO CHANGE TO SCOPE OF WORK
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
ISSUED
05/18/2009
JMA
05/29/2009
05/29/2009
Owner
RIO SD PLAZA II MASTER LLC
C/O NEWPORT NATIONAL CORPORATION
1525 FARADAY AVE #100
CARLSBAD CA 92008
Plan Check Revision Fee
Additional Fees
$12000
$000
Total Fees $12000 Total Payments To Date $12000 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Ca r
Plan Check Revision
Project Address 2.H6 /WC.
Building
Original Plan Check ....
Date
Name of Business at Project Address
Contact QV\frs' Sc(££ Ph (flfl ."SOD Email
Contact Address
General Scope of Work TCn(H\)r '^Tnp.eA.frVngrrt'
City Zip
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 Elements revised
Plans D Calculations Q Soils Energy 0 Other
2
Describe revisions in detail
fyhonq^. of e\tc^\c^\ (hrfoactoe-o '
^
PCR09060 2173 SALKAV 250
VENTANA REAL NEW ELECTRICAL
' CONTRACTOR/ NO CHANGE TO SCDPF OF w^PK !
i PCR
i Lot# CHRIS SARS i|
i I
i
j
--- . .. _ _ _ . .'
3
List page(s) where
each revision is
shown
£-lj &IO-^l^j
p.-2.-e-^
4
List revised sheets
that replace
existing sheets
5 Does this revision, in any way, alter the exterior of the project? [~] Yes
6 Does this revision add ANY new floor area(s)? D Yes
7 Does this revision affect any f/re related issues? LH Yes
8 Is this a complete set? G Yes
^Signature
1635 Faraday Avenue, Cartsbad, CA 92008 Phone 760-602-2717/2718/2719 Fax 760-602-8558
EsGil Corporation
In Partnership with government for (Building Safety
DATE May 28, 2009 Q APPLICANT
^T^^>JURISDICTION Carlsbad TTPLAN REVIEWER
a FILE
PLAN CHECK NO O9-453 REV (PCR09-60) SET I
PROJECT ADDRESS 2173 Salk Avenue, Suite #250
PROJECT NAME Spec Suite #250
[XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Bryan Zuppiger Enclosures Original Approved Plans
Esgil Corporation
GA D MB D EJ D PC 05/21/20O9
trnsmtl dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
Carlsbad O9-453 REV (PCRO9-6O)
May'^S, 2OO9
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO O9-453 REV (PCRO9-6O)
PREPARED BY Bryan Zuppiger DATE May 28, 2009
BUILDING ADDRESS 2173 Salk Avenue, Suite #250
BUILDING
PORTION
ti rev
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
Rlrln Pprmit FPP bv OrHins
AREA
(Sq Ft)
cb
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE ($)
Plan Check Fee by Ordinance
Type of Review Complete Review
$107 50
n
11
Repetitive Fee
1 Repeats
D Other
I— , Hourlv
EsGil Fee
1
$8600
G Structural Only
Hr
$8600|
Based on hourly rate
Comments
-ifO
i
o! O
±5g35 gg
CO UJ <r- > i5 §o
z <ip:
0
O
oo